Sanitary and Environmental Engineering I (4 th Year Civil)

Similar documents
WASTEWATER TREATMENT (1)

Domestic Waste Water (Sewage): Collection, Treatment & Disposal

Waste Water treatment

Definition separation of unstable and destabilized suspended solids from a suspension by the force of gravity

14. SCREENS. in the Figure 8.1. BARS TROUGH

Screening, Definition: The unit involved is called a screen.

13.8 SEWAGE TREATMENT FLOW SHEET

CHAPTER 10 PRELIMINARY TREATMENT

Physical water/wastewater treatment processes

Liquid Stream Fundamentals: Grit Removal

ENVIRONMENTAL ENGINEERING. Chemical Engineering department

WASTEWATER TREATMENT

Figure Trickling Filter

INITIAL TREATMENT By Kenny Oyler. Headworks:

WASTE WATER TREATMENT SYSTEM

Sanitary Sewer Systems. Sewage Collection System. Types of Sewage 10/12/2016. General Overview

Wastewater Pollutants & Treatment Processes. Dr. Deniz AKGÜL Marmara University Department of Environmental Engineering

Sludge recycling (optional) Figure Aerobic lagoon

CTB3365x Introduction to Water Treatment

Dissolved Oxygen (DO):

Wastewater treatment objecives

ATTACHMENT 1 GENERAL FACILITY INFORMATION. BOD5 mg/l mg/l TSS mg/l mg/l NH3-N mg/l mg/l

Wastewater Treatment Works... The Basics

Secondary Wastewater Treatment

American Water College 2010

American Water College 2010

Primary: Removal of a portion of the suspended solids and organic matter from the wastewater by gravity

Chapter 11. Secondary Clarifiers

Wastewater Treatment Processes

OPERATION AND MANAGEMENT OF WASTEWATER TREATMENT PLANTS

19. AEROBIC SECONDARY TREATMENT OF WASTEWATER

ECO Smart Aerobic Waste Water Treatment System. Optimising the re-use and recycling of waste water

IMPROVED BIO-TOWER TECHNOLOGY MUNICIPAL SEWAGE TREATMENT

ENVIRONMENTAL ENGINEERING-I

NC-PC Industry Day Pretreatment 101. Industrial Waste Impacts on POTW Treatment Processes. Dawn Padgett Operations Manager Charlotte Water

FAYOUM CITY SEWAGE TREATMENT PLANT, DEVELOPMENT STAGES, CASE STUDY

Module 19 : Aerobic Secondary Treatment Of Wastewater. Lecture 24 : Aerobic Secondary Treatment Of Wastewater

chapter-3- treatment processes

CTB3365x Introduction to Water Treatment

Air Lift Pumps (Grit Pump) ST-027

Wastewater Plant Tour. There Is Gold In Them There Plants

Water and Wastewater Engineering Prof. C. Venkobacher Department of Civil Engineering Indian Institute of Technology, Madras Lecture-17

Water and Wastewater Engineering Dr. Ligy Philip Department of Civil Engineering Indian Institute of Technology, Madras

Course: Wastewater Management

SETTLING REVIEW CHECKLIST

Duffin Creek Water Pollution Control Plant Technical Information

Characterization and Design of Sewage Treatment Plant in Bidar City

WASTEWATER TREATMENT SYSTEM

Industrial Pretreatment WT - Intakes

/ Marley MARPAK Modular Biomedia /

Appendix B-1. Design Calculations for Sewage Treatment Plant

A NEW METHOD FOR EVALUATING PRIMARY CLARIFIERS Alex Ekster and Cristina Pena San Jose/Santa Clara Water Pollution Control Plant City of San Jose

CLR Process. Vertical Loop Configuration

COLD WEATHER NITRIFICATION OF LAGOON EFFLUENT USING A MOVING BED BIOFILM REACTOR (MBBR) TREATMENT PROCESS

Wastewater Treatment Technology and Applications in Industrial Facilities

6.5 Filtration General

National University Of Kaohsiung Taiwan. T.Y.Yeh Professor Department of Civil and Environmental Engineering

ADVENT INTEGRAL SYSTEM

THE INFLUENCE OF CARRIER SIZE AND SHAPE IN THE MOVING BED BIOFILM PROCESS

Module 20: Trickling Filters Answer Key

Performance Evaluation of 137 MLD Sewage Treatment Plant at Kasna U.P., INDIA Faheem Khan, Nitin Sharma, Avneet Kr.

SECTION-I. b) Write a short note on pumping of savage. 4

Compact Waste Water Treatment MBR /MBBR Technology

Science Exploration. DHRITI BHATTACHARJEE Class : VII/C Roll No : 31

2017 Annual Performance Report

Best Practice in Sewage and Effluent Treatment Technologies

Vortex Separator. May be more cost-effective pre-treatment devices than traditional wet or dry basins.

BIOTRANSFORMATION OF SEWAGE IN A TRICKLING FILTER

ANAEROBIC SLUDGE DIGESTION PROCESS. Prepared By Michigan Department of Environmental Quality Operator Training and Certification Unit

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

- 1 - Retrofitting IFAS Systems In Existing Activated Sludge Plants. by Glenn Thesing

CEE 371 May 14, 2009 Final Exam

Packaged Wastewater Treatment Systems for Individual Homes and Small Communities. Mark Gross Orenco Systems, Inc. Sutherlin, OR USA.

CITY OF LONDON ENVIRONMENTAL & ENGINEERING SERVICES WASTEWATER TREATMENT OPERATIONS DIVISION

1/11/2016. Types and Characteristics of Microorganisms. Topic VI: Biological Treatment Processes. Learning Objectives:

ENHANCING THE PERFORMANCE OF OXIDATION DITCHES. Larry W. Moore, Ph.D., P.E., DEE Professor of Environmental Engineering The University of Memphis

MARPAK modular biomedia WASTEWATER TREATMENT

Proprietary AquaTron technology incorporates three (3) innovative features that increase its efficiency and reduces cost:

experience and innovations

Department of Environmental Quality

Wastewater Treatment clarifier

UPGRADING GAZA WASTEWATER TREATMENT PLANT. Gaza City is populated with 550,000 inhabitants and it forms 45% of the Gaza strip population.

Marginal Water Treatment by Combination of Two Stages of Stepped Cascade Weir and Spray Aerator

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 4000 as described below and as shown on the drawings.

1 Construction The sewage treatment plant (STP) is to be an Icon-Septech Pty Ltd Turbojet 5000 as described below and as shown on the drawings.

WASTEWATER DEPARTMENT. Bentonville Wastewater Treatment Plant Facts:

CHARECTERIZATION OF SEWAGE AND DESIGN OF SEWAGE TREATMENT PLANT

State-of-the-art Treatment Technology for Challenging Wastewaters Generated from Processing Opportunity Crudes

EFFECTS, MANAGEMENT, AND REMOVAL PRESENTED BY MARK MANN, P.E.

HUBER Drum Screen LIQUID

SIMPLE and FLEXIBLE ENERGY SAVINGS And PERFORMANCE ENHANCEMENT for OXIDATION DITCH UPGRADES

Enviro Voraxial Technology

Study of Oxidation Ditch using Cascade Aerator for Dairy Waste

INTEGRATED DECENTRALISED WASTE WATER TREATMENT SYSTEMS

Study and Modification of Sewage Treatment Plant, at Jaspur


WASTEWATER TREATMENT THAT CONTAMINATED WITH LEAD

Tour of Regional Water Reclamation Facility

SEWAGE TREATMENT PLANT TECHNOLOGY BY COMPLETE WATER SOLUTION BHALERAO HEIGHTS, AKURDI, PUNE

Advanced Wastewater Treatment and Disposal Systems. Wastewater Utility Operation and Management for Small Communities

Transcription:

Sanitary and Environmental Engineering I (4 th Year Civil) Prepared by Dr.Khaled Zaher Assistant Professor, Public Works Engineering Department, Faculty of Engineering, Cairo University

Wastewater Flow Diagram Inlet Chamber Screening Grit Removal Primary Sedimentation Primary Sludge Biological Treatment Final Sedimentation Secondary Sludge Final Disposal

Screening A screen is a device with openings, generally of uniform size, that is used to retain solids found in the influent wastewater to the treatment plant. The principle role of screening is to remove coarse materials from the flow stream that could: 1. damage subsequent process equipment 2. reduce overall treatment process reliability and effectiveness 3. contaminate waterways Fine screens are sometimes used in place of or following coarse screens where greater removals of solids are required (1) protect process equipment or (2) eliminate materials that may inhibit the beneficial reuse of biosolids. 3

The screening element may consist of parallel bars, rods or wires, wire mesh, or perforated plate, and the openings may be of any shape but generally are circular or rectangular slots. A screen composed of parallel bars or rods is often called a ''bar rack'' or a coarse screen and is used for removal of coarse solids. The materials removed by these devices are known as screenings. Hand cleaned coarse screens are used when the flow is not more than 5000 m 3 /d, while mechanical cleaned coarse screens are used when the flow is more than 5000 m 3 /d. 4

5

6

To design a coarse screen: Q = A * V V = V *sin θ A = area = ((n-1)*s) * d W = (n-1)*s + n*w h l = * (V 2 - v' 2 )/2g 7

where : S = distance between bars n = number of bars d = depth V = horizontal velocity between bars w= width or diameter of one bar W = Total width of screen h l = head loss (m) C = an empirical discharge coefficient to account for turbulence and eddy losses, typically 0.7 for a clean screen and 0.6 for a clogged screen v' = approaching velocity in upstream g = 9.81 m/s 2 8

Grit Removal Grit chambers are designed to removal grit, consisting of sand, gravel, cinders, or other heavy solid materials that have subsiding velocities or specific gravities substantially greater than those of the organic solids in wastewater. Grit chambers are most commonly located after the bar screens and before the primary sedimentation tanks. Primary sedimentation tanks function for the removal of heavy organic solids. In some installations, grit chambers precede the screening facilities. Generally, the installation of screening facilities ahead of the grit chambers makes the operation and maintenance of the grit removal facilities easier. 9

Grit chambers are provided to: (1) protect moving mechanical equipment from abrasion and accompanying abnormal wear; (2) reduce formation of heavy deposits in pipelines, and channels, and conduits; and (3) reduce the frequency of digester cleaning caused by excessive accumulations of grit. 10

There are two general types of grit chambers: horizontal flow or aerated type. In horizontal flow type, the flow passes through the chamber in a horizontal direction and the straight-line velocity of flow is controlled by the dimensions of the unit, an influent distribution gate, and a weir at the effluent end. The aerated type consists of a spiral flow aeration tank where the spiral velocity is induced and controlled by the tank dimensions and quantity of air supplied to the unit. Design of grit chambers is commonly based on the removal of grit particles having as specific gravity of 2.65 and a wastewater temperature of 15.5 o C. However, analysis of grit-removal data indicates the specific gravity ranges from 1.3 to 2.7. 11

Generally, what is removed as grit is predominantly inert and relatively dry material. However, grit composition can be highly variable, with moisture content ranging from 13 to 65 percent, and volatile content from 1 to 56 percent. The specific gravity of clean grit particles reaches 2.7 for inerts but can be as low as 1.3 when substantial organic material is agglomerated with inerts. A bulk density of 1600 kg/m 3 is commonly used for grit. Grit particles 0.2 mm and larger have been cited as the cause of most downstream problems. 12

13

Horizontal flow Grit Removal: Rectangular or square horizontal flow grit removal have been used for many years. Rectangular horizontal flow grit chambers is the oldest type of grit chamber used. It is velocity-controlled type. these units were designed to maintain a velocity as close to 0.3 m/s as practical and to provide sufficient time for grit particles to settle to the bottom of the channel. The design velocity will carry most organic particles through the chamber and will tend to resuspend any organic particles that settle but will permit the heavier grit to settle out. 14

The basis of design of rectangular horizontal flow grit chambers is that, under the most adverse conditions, the lightest particle of grit will reach the bed of the channel that will be retained on a 0.2 mm diameter (65 mesh) screen, although many chambers have been designed to remove grit particles retained on a 0.15 mm diameter (100 mesh) screen. The length of the channel will be governed by the depth required by the settling velocity and the control section, and the cross sectional area will be governed by the rate of flow and by the number of channels. Allowance should be made for inlet and outlet turbulence. Grit removal from horizontal flow chambers is accomplished usually by a conveyor with scrapers. In small plants, grit chambers are sometimes cleaned manually. 15

Design criteria of horizontal flow grit chamber according to Egyptian Code: Horizontal velocity = 0.25-0.5 m/s Detention time = 45-90 s Surface loading rate should not exceed 1200 m 3 /m 2 /d Water Depth = 0.6-1 m Width of chamber = (1-2) water depth Vertical velocity = 2 cm/s for particles greater than 0.2 mm Length of chamber = (20-30) water depth Amount of grit settled = 100-250 l/1000 m 3 /d 16

Aerated Grit Chambers: In aerated grit chambers, air is introduced along one side of a rectangular tank to create a spiral flow pattern perpendicular to the flow through the tank. The heavier grit particles that have higher settling velocities settle to the bottom of the tank. Lighter, principally organic, particles remain in suspension and pass through the tank. The velocity of roll or agitation governs the size of particles of a given specific gravity that will be removed. If the velocity is too great, grit will be carries out of the chamber; if it is too small, organic material will be removed with the grit. Fortunately, the quantity of air is easily adjusted, almost 100 percent removal will be obtained and the grit will be well washed. Grit that is not well washed and contains organic matter is an odor nuisance and attracts insects. 17

Aerated grit chambers are nominally designed to remove 0.21 mm diameter (65 mesh) or larger, with 2 to 5 minute detention periods at the peak hourly rate of flow. The cross section of the tank is similar to that provided for spiral circulation in activated sludge aeration tanks, except that a grit hopper about 0.9 m deep with steeply sloping sides is located along one side of the tank under the air diffusers. The air diffusers are locates about 0.45 to 0.6 m above the normal plane of the bottom. Influent and effluent baffles are used frequently for hydraulic control and improved grit removal effectiveness. 18

Wastewater will move through the tank in a spiral path and will make two to three passes across the bottom of the tank at maximum flow and more passes at lesser flows. Wastewater should be introduced in the direction of the roll. To determine the required head loss through the chamber, the expansion in volume caused by the air must be considered. In areas where industrial wastewater is discharged to the collection system, the release of volatile organic compounds (VOCs) by the air agitation in aerated grit chambers needs to be considered. The release of significant amounts of VOCs can be a health risk to the treatment plant operators. Where release of VOCs is an important consideration, covers may be required or nonaerated type grit chambers used. 19

20

Design criteria of aerated grit chamber according to Egyptian Code: Detention time = 2-5 min Surface loading rate should not exceed 1000 m 3 /m2/d Water depth = 3-5 m Spiral velocity of water = 0.1-0.2 m/s Horizontal velocity = 0.25-0.3 m/s Length = 7.5-20 m Width of chamber should not exceed 2 m Rate of air supply = 0.3-0.7 m3/min/m length of chamber Amount of grit settled = 100-250 l/1000 m 3 /d 21

Example: Design an aerated grit chamber for the treatment of municipal wastewater. The average flow rate is 0.5 m 3 /s and the peaking factor is 2.75. Solution 1. Peak flow = 0.5*2.75 = 1.375 m 3 /s 2. Assume 2 grit chambers will be used and detention time = 3 min Volume of one chamber = (1.375/2)*3*60 = 123.75 m 3 3. Assume Depth = 4 m, and Width = 2 m then Length = 123.75/(4*2) = 15.5 m 4. Assume air supply requirement = 0.3 m 3 /min/m of length then Air required = 0.3*15.5 = 4.65 m 3 /min for each chamber Total air supply required = 4.65 * 2 = 9.3 m 3 /min 5. Assume amount of grit = 150 l/1000 m 3 /d Grit volume = 1.375*150*60*60*24/1000*1000 = 17.82 m 3 /d 22

Primary Sedimentation The objective of treatment by sedimentation is to remove readily settleable solids and floating material and thus reduce the suspended solids content. Primary sedimentation is used as a preliminary step in the further processing of the wastewater. Efficiently designed and operated primary sedimentation tanks should remove from 50 to 70 % of the suspended solids and from 25 to 40 % of the BOD. Almost all treatment plants use mechanically cleaned sedimentation tanks of standardized circular or rectangular design. Two or more tanks should be provided so that the process may remain in operation while one tank is out of service for maintenance and repair work. 23

Sedimentation tanks are normally designed on the basis of a surface loading rate ( commonly termed ''overflow rate'') expressed as cubic meters per square meter of surface area per day, m 3 /m 2.d. The selection of a suitable loading rate depends on the type of suspension to be separated. When the area of the tank has been established, the detention period in the tank is governed by water depth. Overflow rates in current use result in nominal detention periods of 2.0 to 2.5 h, based on average design flow. It should be emphasized that overflow rates must be set low enough to ensure satisfactory performance at peak rates of flow. 24

25

Design Criteria according to the Egyptian Code: Rectangular tanks Water depth = 3-5 m, Length should not exceed 40 m, Width = 6-12 m Width : length = 1:3-1:5 Bottom slope = 1:40 or 1: 50 Detention time for tanks followed by trickling filter = 1.5-3 hrs Detention time for tanks followed by activated sludge = 1-1.5 hrs Detention time for tanks without secondary treatment = 3-4 hrs Surface loading for tanks without secondary treatment = 1-1.33 m/s Surface loading for tanks followed by biological filters= 1-2 m/s Surface loading for tanks followed by aeration tanks= 1-1.5 m/s 26

Circular tanks Water depth = 2.5-4 m, Diameter should not exceed 40 m Bottom slope = 1:10 or 1: 15 Loading on weir = 150-600 m3/m/d Detention time for tanks followed by trickling filter = 1.5-3 hrs Detention time for tanks followed by activated sludge = 1-1.5 hrs Detention time for tanks without secondary treatment = 3-4 hrs Surface loading for tanks without secondary treatment = 1-1.33 m/s Surface loading for tanks followed by biological filters= 1-2 m/s Surface loading for tanks followed by aeration tanks= 1-1.5 m/s 27

BIOLOGICAL TREATMENT Involves biological removal of dissolved organic matter. Supernatant or primary effluent contains high levels of dissolved organic load (Biological Oxygen Demand) Aeration to stimulate aerobic degradation activated sludge reactor trickling filter reactor bacteria degrade organic carbon to CO 2

BIOLOGICAL TREATMENT Bacteria + Organics O 2 New Cells 1) Attached Growth of Bacteria Trickling filters 2) Suspended Growth of Bacteria Activated sludge method

Aerobic secondary sewage treatment - Activated sludge and Trickling filter.

Trickling filters The waste effluent is passed over rocks or other solid materials upon which microbial films have developed. Microbial community in these films degrades organic waste. Passage of waste water through the filter causes the development of (bacteria, protozoa etc.)

Rotating distribution arm sprays primary effluent over circular bed of rock or other coarse media Air circulates in pores between rocks Biofilm develops on rocks and micro-organisms degrade waste materials as they flow past Organisms slough off in clumps when film gets too thick

Filter Material

Activated sludge Involves horizontal flow of WW with a recycle of sludge Sludge is the active biomass formed when organic matter is degraded and oxidized by microorganisms. The process must be provided with air required for bacteria growth There two system of aeration: - Surface aeration - Diffused air system

Activated Sludge (diffused air system)

Thank you E-mail: dr.khaledzaher@cu.edu.eg