SECTION SELF-ADHERING SHEET WATERPROOFING

Similar documents
SECTION SELF-ADHERING SHEET WATERPROOFING (PRM / PROTECTED WALL SYSTEM)

SECTION SELF-ADHERING SHEET WATERPROOFING (650 MEMBRANE SYSTEM)

SECTION ANTI-FRACTURE MEMBRANE UNDERLAYMENT

SECTION SELF-ADHERING SHEET WATERPROOFING (650 MEMBRANE SYSTEM)

MODIFIED BITUMINOUS SHEET AIR BARRIERS

SECTION UNDERSLAB WATERPROOFING WITH INSECT BARRIER

SECTION SELF-ADHERING SHEET WATERPROOFING WITH TERMITE BARRIER

GUIDE SPECIFICATION FOR MEL-ROL : ROLLED, SELF-ADHERING WATERPROOFING MEMBRANE

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

SECTION SHEET MEMBRANE WATERPROOFING

SECTION VAPOR PERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION FLASHING AND SEALING FRAMING WITH NON-CHEMICAL TERMITE BARRIERS

SECTION VAPOR IMPERMEABLE FLUID-APPLIED AIR BARRIER MEMBRANE

SECTION SELF-ADHERING SHEET FLASHING

SECTION FLUID-APPLIED WATERPROOFING

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

SECTION TW-60 Self-Adhering Sheet Waterproofing Membrane

D. Product Test Reports: Based on evaluation of comprehensive tests performed by a qualified testing agency, for waterproofing.

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

** NOTE TO SPECIFIER ** Delete any sections below not relevant to this project; add others as required. A. Section Mechanical Insulation.

Section Pre-Applied Sheet Membrane Waterproofing

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Roof

SECTION TERMITE AND PEST CONTROL AT ABOVE GRADE PLUMBING PENETRATIONS AND BATH TRAPS

SECTION mil thickness COLD FLUID-APPLIED WATERPROOFING

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

SECTION SELF-ADHERING SHEET MEMBRANE WATERPROOFING

SECTION mil thickness REINFORCED LIQUID-APPLIED WATERPROOFING

A. The work of this section includes, but is not limited to, the following:

SECTION MODIFIED BITUMINOUS MEMBRANE ROOFING Peel & Seal

Student Services & Classroom Addition

Polyguard 650 Waterproofing Membrane

1. Rubberized asphalt waterproofing membrane, reinforced. 2. Molded sheet drainage panels. 3. Insulation. 4. Plaza deck pavers.

SECTION MODIFIED BITUMINOUS SHEET WATERPROOFING

Guide Specification for the OSI QUAD Window and Door Flashing System

MINERAL SURFACE CAP SHEET

Perm-A-Barrier NPS (Non Permeable Sheet)

Pacific Polymers Elasto-Deck 5000MR Guide Specification

Delivery, Storage, and Handling

Pacific Polymers Elasto-Deck 5000X2 Guide Specification

Pacific Polymers Elasto-Mat D&G Guide Specification

A. Section includes fluid applied, vapor permeable membrane air barriers.

MODIFIED BITUMINOUS SHEET AIR / VAPOUR BARRIERS SELF ADHESIVE

Pacific Polymers Elasto-Deck BT Guide Specification

PRODUCT GUIDE SPECIFICATION

SPECIFYING EXTRUDED POLYSTYRENE FOR PROTECTED MEMBRANE ROOFING SYSTEM (IRMA)- PMR Short Form Guide Specification

SECTION MANUFACTURED ROOF EXPANSION JOINTS

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

SECTION 07530CP EPDM MEMBRANE ROOFING

DIVISION 7 MARFLEX 5000 FLUID APPLIED AIR & VAPOR BARRIER - 3 PART SPEC 07262

DIVISION 7 - COMMERCIAL FLUID APPLIED DAMPPROOFING 07110

Architectural Roof Products Guide Specifications

Pol-E-Base Modified Bitumen Roof System

Application Specification:

PART 2 - AIR BARRIERS SELF-ADHESIVE

SECTION SELF-ADHERED WATER-RESISTIVE ROOF UNDERLAYMENT

SECTION THERMOPLASTIC POLYOLEFIN (TPO) ROOFING PART 1 - GENERAL 1.1 RELATED DOCUMENTS

BAYBLOCK HT/BAYBLOCK HT BASE

PERM-A-BARRIER NPS Detail Membrane

A Design Review of Waterproofing Codes

838 Coatings System Specification Single-Ply Restoration (838 SPR)

Architectural Roof Products Guide Specifications

Application Specification:

PRODUCT INFORMATION. 1/ Version #4

SILICONE ROOF COATING RESTORATION (RCR) SYSTEM OVER METAL ROOF PANEL

E. Section Polymer Modified Cement Waterproofing. K. Section Sub drainage: Foundation perimeter drainage.

Architectural Roof and Wall Products Guide Specifications

DIVISION 07 - THERMAL & MOISTURE PROTECTION

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION COLD APPLIED RUBBER MODIFIED ASPHALT WATERPROOFING

Architectural Roof and Wall Products Guide Specifications

SECTION THERMAL INSULATION

EFFISUS EASYREPAIR MEMBRANE

Guideline Specification ACRYMAX ARS-1-C Reinforced Composite Elastomeric Membrane System for Concrete Roofs Fluid-Applied Roofing

Perm-A-Barrier VPS (Vapor Permeable Sheet)

WATERPROOFING TAMKOWATERPROOFING.COM

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Product Guide Specification

Short Form Guide Specification. Specifying Extruded Polystyrene Roof Insulation- STYROFOAM DECKMATE Plus Tapered

G October 2018

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

MasterSeal HLM Liquid cold-applied elastomeric waterproofing membrane system

RECOMMENDED DESIGN SPECIFICATION

Extreme Sealing Tape

Florock Seamless Flooring Systems

DMS-6300, Waterproofing

SOLAR COATING SYSTEMS SYSTEM EMULSION /ACRYLIC. Specification for Built-Up Roofing MULSION/A 1.01 SUMMARY

A. This specification describes the sealing of vertical joints/cracks with a one-component, gungrade, elastomeric sealants. B.

G October 2018

MATERIALS CHECKLIST POLYGUARD AIRLOK FLEX VP AIR BARRIER SYSTEM: ABOVE-GRADE FLUID-APPLIED MEMBRANE

AFM Anti-Fracture Membrane & AFM-WM Anti-Fracture Waterproofing Membrane Three-Part Specifications

CRCA Education Series. Self-Adhering Membrane Roofing Systems for Low Slope Roofs

ROOFING EPDM ELASTOMERIC SHEET ROOFING FULLY ADHERED- CONVENTIONAL

PERM-FLEX ASSEMBLY DIRECT APPLICATION TO CEMENTITIOUS SUBSTRATES MANUFACTURERS SPECIFICATION / SECTION 09960

SECTION AIR / MOISTURE / VAPOR BARRIERS 1

Liquid-Applied Roof Solutions ACRYLIC & SILICONE COATINGS PRIMERS & ACCESSORIES

CIM 800 / CIM 1000

MEMBRANE 510/510R Low VOC Flexibilized, Urethane Membrane mils

A. Submit product data sheets and literature verifying physical properties of materials.

WATERPROOFING TAMKOWATERPROOFING.COM

Transcription:

SECTION 07 13 26 SELF-ADHERING SHEET WATERPROOFING This guide specification has been prepared by Polyguard Products Inc., in printed and electronic media, as an aid to specifiers in preparing written construction documents for self-adhering sheet membranes. Balconyguard is a 60-mil nominal, cold-applied, adhesive waterproofing sheet used specifically on wood deck balcony structures that will be covered with concrete. Balconyguard 48-inch wide rolls reduce edge seam occurrence by up to 25% when compared to traditional 36 wide material and thereby reduces the number of seams necessary. Edit entire master document to suit project requirements. Modify or add items as necessary. Delete items which are not applicable. Words and sentences may contain choices to be made regarding inclusion or exclusion of a particular item or statement. This section may include performance-, proprietary-, and/or descriptive-type specifications. Edit to avoid conflicting requirements. Editor notes to guide the specifier are included between lines of asterisks to assist in choices. Remove these editor notes before final printing of guide specification. This guide specification is written around the Construction Specifications Institute (CSI) Section Format standards. For assistance on specific product applications, please contact our offices or any of our local product representatives throughout the country. Polyguard Products Inc. reserves the right to modify these guide specifications at any time. Updates for this guide specification will be posted on the manufacturer s web site and/or in printed media as they occur. Manufacturer makes no expressed or implied warranties regarding content, errors, or omissions in the information presented. PART 1 GENERAL 1.01 SECTION INCLUDES A. Surface preparation. B. Application of self-adhering membrane system. 1.02 RELATED SECTIONS Specifier Notes: Edit the list of related sections as required for the project. List other sections dealing with work directly related to this section. A. Section 07 22 00 - Roof and Deck Insulation. 1.03 REFERENCES A. ASTM D 1000 (04) Standard Test Methods for Pressure Sensitive Adhesive Coated Tapes Used for Electrical and Electronic Applications. B. ASTM D 412 Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers-Tension. C. ASTM E 96 (Method B) Standard Test Methods for Water Vapor Transmission of Materials. D. ASTM D 882 (02) Standard Test Method for Tensile Properties of Thin Plastic Sheeting. E. ASTM D 903 (98) Standard Test Method for Peel or Stripping Strength of Adhesive Bonds. F. ASTM E 154 Standard Test Methods for Water Vapor Retarders Used in Contact with Earth Under Concrete Slabs, on Walls, or as Ground Cover. G. ASTM D 1970 Standard Specification for Self Adhering Polymer Modified Bituminous Sheet Materials Used as Steep Roofing Underlayment for Ice Dam Protection. Polyguard Products 8-2013 07 13 26-1 Self-Adhering Sheet Waterproofing

1.04 SUBMITTALS A. Product Data: Submit manufacturer s product data, installation instructions, use limitations and recommendations. 1.05 QUALITY ASSURANCE A. Manufacturer Qualifications: Sheet Membrane must be manufactured by a company with a minimum of ten (10) years of experience in the production and sales of membrane waterproofing materials. B. Applicator Qualifications: A firm having at least three (3) years of experience in applying these types of specified materials and specifically accepted in writing by the membrane system manufacturer. C. Materials: For each type of material required to complete the work of this section, provide primary materials which are the products of a single manufacturer. D. Pre-Application Conference: A pre-application conference shall be held to establish procedures and to review conditions, installation procedures, and coordination with other related work. Meeting agenda shall include review of special details and flashing. E. Manufacturer s Representative: Arrange to have trained representative of the manufacturer on-site periodically to review installation procedures. 1.06 DELIVERY, STORAGE, AND HANDLING A. Deliver materials to site in manufacturer's original, unopened containers and packaging, with labels clearly identifying product name and manufacturer. B. Store materials in a clean, dry area in accordance with manufacturer's instructions. C. Store adhesives at temperatures of 40 o F (5 o C) and above to facilitate handling. D. Store membrane cartons on pallets. E. Keep away from sparks and flames. F. Completely cover when stored outside. Protect from rain. G. Protect materials during handling and application to prevent damage or contamination. H. Avoid use of products which contain tars, solvents, pitches, polysulfide polymers, or PVC materials that may come into contact with waterproofing membrane system. 1.07 PROJECT CONDITIONS A. Work should be performed only when existing and forecasted weather conditions are within the limits established by the membrane manufacturer. B. Warn personnel against breathing of vapors and contact with skin and eyes; wear appropriate protective clothing and respiratory equipment. C. Keep flammable products away from spark or flame. Post No Smoking signs. Do not allow use of spark-producing equipment during application and until all vapors have dissipated. D. Maintain work area in a neat and workmanlike condition. Remove empty cartons and rubbish from the site daily. 1.08 WARRANTY Polyguard Products 8-2013 07 13 26-2 Self-Adhering Sheet Waterproofing

A. Manufacturer warrants only that this product is free of defects, since many factors which affect the results obtained from this product are beyond our control; such as weather, workmanship, equipment utilized, and prior condition of the substrate. We will replace, at no charge, proven defective product within twelve (12) months of purchase, provided it has been applied in accordance with our written directions for uses we recommended as suitable for this product. Proof of purchase must be provided. A five (5) year material or system warranty may be available upon request. Contact Polyguard Products, Inc. for further details. PART 2 PRODUCTS 2.01 MANUFACTURER A. Polyguard Products Inc. P.O. Box 755 Ennis, TX 75120-0755; Phone: (214) 515-5000 Fax: (972) 875-9425 Email: info@polyguardproducts.com 2.02 SYSTEM MATERIALS A. Self-adhesive Membrane Waterproofing: Shall be Polyguard Balconyguard, a 60-mil rubberized asphalt membrane consisting of a high-density polyethylene film bonded to a layer of rubberized asphalt meeting or exceeding the following requirements: PHYSICAL PROPERTIES PROPERTY TEST METHOD TYPICAL VALUE MEMBRANE THICKNESS ASTM D 1000 60 mils TENSILE STRENGTH - MEMBRANE ASTM D 412 Modified Die C 841 PSI TENSILE STRENGTH - FILM ASTM D 882 6300 PSI ELONGATION ASTM D 412 Modified Die C 730% PERMEABILITY ASTM E 96 Method B 0.017 perms-inch PEEL ADHESION ASTM D 903 20.0 lb./in. width LAP ADHESION ASTM D 1876 12 lbs. LOW TEMPERATURE FLEXIBILITY (-15 F) ASTM D 1970 Modified Pass PUNCTURE RESISTANCE - MEMBRANE ASTM E 154 61 lbs. 2.03 SYSTEM ACCESSORIES A. Surface Primer Adhesive: A. Surface Primer Roller-grade Adhesive: 1. Polyguard 650 LT Liquid Adhesive: A rubber-based adhesive in solvent solution which is specifically formulated to provide excellent adhesion with the Polyguard Waterproofing Membranes to prime all structural concrete, masonry, insulation, or wood surfaces. It is designed to be used on applications down to 25 F (-4ºC). 2. Polyguard California Sealant: A rubber-based sealant in solvent solution which is specifically formulated to provide excellent adhesion with the Polyguard Waterproofing Membrane. The VOC (Volatile Organic Compound) content meets the South Coast Air Quality Management District regulations established under the February 1, 1991 version of Rule 1168 ) (2) Adhesion and Sealant Applications. California Sealant is classified as an Architectural Sealant Primer Porous, with VOC of 521 g/l. Current SCAQMD regulations for this type sealant primer are 775 g/l. 3. Polyguard Shur-Tac Liquid Adhesive: Roller-grade, polymer emulsion based adhesive. It is used to prime all structural concrete, masonry, insulation, or wood surfaces. Designed to be used on applications down to 25 F (-4 C). B. Liquid Membranes: Polyguard Products 8-2013 07 13 26-3 Self-Adhering Sheet Waterproofing

1. Polyguard LM-85 SL (Self-Leveling): Two-component, quick-curing urethane material specifically formulated to be used as a flood coat waterproofing membrane for new and recondition work. May be applied down to 25 F (-4 C). Coverage rate is approximately 25 sq. ft. per gallon. 2. Polyguard LM-95: Two-component, trowel-applied, quick-cure, urethane waterproofing membrane to be used in a variety of applications in conjunction with Polyguard waterproofing system. C. Detail Sealant: 1. Polyguard Detail Sealant PW : Single-component, elastomeric sealant. It is an environmentally friendly, non-isocyanate product that replaces silicone and urethane sealants. A low VOC/HAPS free, high-performance, flexible sealant that is solvent free. Used on substrates including: Rigid PVC, bare aluminum, stainless steel, galvanized steel, anodized aluminum, tile, wood, concrete, FRP, polystyrene, molded polyurethane, polyester and ABS. D. Drainage Composite: 1. Polyguard Lowflow Protection and Drainage System: High strength, multi-layer fabric composite in a 4' x 200' roll. Its purpose is to protect underlying waterproofing membranes and is suitable for most clay soil conditions. 2. Polyguard Polyflow 18 Drainage Mat: Two-part, prefabricated, geocomposite drain consisting of a formed polystyrene core covered on one side with woven monofilament filter fabric. The fabric allows water to pass into the drain core while restricting the movement of soil particles which might clog the core. The core allows the water to flow to designated drainage exits. E. Corner Boot: 1. The Polyguard BG Outside Corner Boot: 60-mil combination of rubberized asphalt bonded to polyethylene. The adhesive surface is covered with a release liner which will be removed prior to application. F. Flashing: PART 3 EXECUTION 3.01 EXAMINATION 1. Polyguard 105-12 Flashing Membrane is a strong, pliable, 105-mil, self-adhesive sheet consisting of high-density polyethylene film bonded to a layer of rubberized asphalt waterproofing compound with split release sheet to conform to 90 angles. A. Examine surfaces to receive self-adhering membrane. Notify the general contractor if surfaces are not acceptable. Do not begin surface preparation or application until unacceptable conditions have been corrected. 3.02 SURFACE PREPARATION A. Protect adjacent surfaces not designated to receive waterproofing. B. Clean and prepare surfaces to receive waterproofing in accordance with manufacturer's instructions. C. Do not apply waterproofing to surfaces unacceptable to manufacturer. Polyguard Products 8-2013 07 13 26-4 Self-Adhering Sheet Waterproofing

D. Bridge gaps between supporting substrates with Polyguard Detail Sealant PW or LM-95 to establish full support of the membrane. 3.03 APPLICATION A. Priming: 1. Apply materials to substrates that are sound, dry, frost free and that have been primed with one of the listed primers listed in section 2.03 System Accessories. B. Membrane Installation Positive-Slope Deck: 1. Install each material as shown in the Polyguard Balconyguard Data Sheet graphics. Adhere Balconyguard in a shingled manner as the protective release sheet is peeled away. 2. Apply in temperatures of 40 o F (5 o C) and rising, then roll over the surface of installed membrane materials with a hard surfaced rubber roller to insure intimate contact with the receiving substrate. 3. Adhere overlaps to a wiped clean PET surface. 4. Cover the application within thirty (30) days. 5. Drip edges and T-bars are an important part of the waterproofing assembly as they direct water to and over the face of the exterior finish below the deck. Polyguard does not manufacture, fabricate or distribute metal drip edges or T-bars. Those represented in the Polyguard Balconyguard data sheet graphics are representative of ones readily found in the marketplace. C. Membrane Installation Zero-Slope Deck: 1. If project has zero-sloped deck, contact manufacturer for project specific details. D. Protection/Drainage: 1. Apply protection board and/or drainage composite and perimeter drainage composite in accordance with manufacturer s written directions. END OF SECTION Polyguard Products 8-2013 07 13 26-5 Self-Adhering Sheet Waterproofing