DuraPlus. All-fuel, triple-wall chimney system. UL 103 HT.

Similar documents
Simpson Dura-Vent Engineered Excellence

Simpson Dura-Vent Engineered Excellence

DVL. DuraBlack. Double-wall interior close clearance stovepipe for connecting woodstoves to chimney. ULC S641.

DuraLiner. Insulated, double-wall masonry relining. UL 1777, ULC S635, and ULC S640.

Vent Termination Chart. horizontal Termination Kit A. horizontal Termination Kit C. Chimney Liner Termination Kit. DirectVent Pro Direct Vent

DirectVent Pro. Simpson Dura-Vent Engineered Excellence

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Online Update 10/2011 Current Print Version L820 1/2011

P36-10 / P36E-10 Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.

APPLICATION AND LISTING

Technical and Dimensional Data. Saf-T Vent SC

DuraFlex. Flexible stainless steel relining for masonry chimney. UL 1777 and ULC S635.

Gas Fireplaces. P36D-10 Gas Fireplace. Unit Dimensions With Vignette Faceplate. *** Important: Framing height requires consideration of the hearth

Gas Fireplaces. P33-10/P33E-10 Gas Fireplace P33 DIMENSIONS WITH VIGNETTE FACEPLATE CLEARANCES WITH VIGNETTE FACEPLATE

Dur aflex stainless steel

PelletVent Cornvent. Installation Instructions. C o m p l e t e V e n t i n g S o l u t i o n s f o r t h e H e a r t h I n d u s t r y

Installation Instructions

Regency Horizon HZ30E Gas Fireplace

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 5" Round 6", 8" Round and Oval.


P36 / P36E Gas Fireplace. 11 W.C. (2.74 kpa) 10 W.C. (2.49 kpa) 6.4 W.C. (1.59 kpa) 22,000 BTU/h (6.44 kw) 28,500 BTU/h (8.35 kw)

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Venting System For Direct Vent Gas Stoves and Fireplaces. DirectVent Pro

Installation Instructions. Pellet-fuel venting system. PelletVent

INSTALLATION INSTRUCTIONS OPERATION AND MAINTENANCE MANUAL Models event SD, event, Event Plus, and event Plus2 (Condensing Boiler Systems)

Installation Instructions. Air-Cooled, All-Fuel Chimney for Fireplaces. DuraChimney ii

P36 - P36D Zero Clearance Direct Vent Gas Fireplace. 12 W.C. (3.00 kpa) 11 W.C. (2.74 kpa) 2.9 W.C. (0.72 kpa) 15,000 BTU/h (3.

FIREPLACE INSERT ENCLOSURE INSTALLATION INSTRUCTIONS

RECOMMENDED STANDARDS for the INSTALLATION of WOODBURNING STOVES

Installation Instructions. Air-Cooled Chimney for Isokern Fireplaces

Gas venting. Table of Contents. DirectVent 4 x 6 5/ DirectVent 5 x DirectVent Pro Kits DirectVent CVS... 7

Gas Fireplaces. B41XTE-10 Gas Fireplace. Framing Dimensions: Unit Dimensions: Non-Combustible 1012mm Requirements: V Opening for gas connection

Contemporary Collection

Gas Fireplaces. P33 Zero Clearance Direct Vent Gas Fireplace. *** Important: Framing height requires consideration of the hearth

B36XTCE Gas Fireplace

EPV Pellet Vent Pellet Stove Venting System Installation Instructions

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

B41XTCE Gas Fireplace

Installation Instructions. High-Temperature, Factory Insulated Double-Wall Masonry Relining system 6" - 8", Round and Oval.

Light Stainless Flexible Liner

DuraFlex AL. Installation Instructions

CHIMNEYS AND FIREPLACES

BuildingName The Description of the Project P DOCUMENTS

CHIMNEYS AND FIREPLACES

Ventinox. Welded, flexible and rigid relining for masonry chimney. UL 1777, ULC S635 and ULC S640.

ICC - Model VIP+ Positive Pressure Chimney System and Grease Duct

SECTION NON-STRUCTURAL METAL FRAMING

Chimney Lining Systems

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

Fireplaces and Chimneys

SI T T FST

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

150MM FREE STANDING WOOD FIRE FLUE KIT MKIII INSTALLATION INSTRUCTIONS

GENERAL MECHANICAL SYSTEM REQUIREMENTS

PolyPro Polypropylene venting products for high-efficiency condensing appliance installations. Listed to ULC-S636.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

SAFETY PRECAUTIONS. Do not operate your stove if you smell smoke coming from it. Turn it off, monitor it, and call your dealer.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Installation Instructions. Converting a Class-A Metal Chimney or Masonry Chimney to a Direct Vent System. DirectVent Pro

RENDERED TO SLEEPY HOLLOW CHIMNEY SUPPLY, LTD. 85 EMJAY BLVD. BRENTWOOD, NY 11717

Installation Instructions

EXCELPrime 18 Clearance Stove Pipe INSTALLATION AND MAINTENANCE INSTRUCTIONS

Please consult the manufacturer s installation manual for all details and requirements before making a final design layout decision.

Masonry Thimble Chimney Serving Appliance

Nouveau BBQ Single Flue

DuraChimney II Shroud

TC42 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

TC36 FOR ARCHITECTS & DESIGNERS SERIES D2. Dimensions Clearances Venting

Builder's Manual for Ortal Fireplaces

SLOPED ROOF. Ajustable sloped flashing from : 2/12 to 7/12 Ventilation area : 50 to 250 ft. 2

Z-Vent Model SVE Series III

Installation Instructions. DuraTech 5" - 24" Chimney Shroud. DuraTech Shroud

TC42 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

Installation Instructions

1. Non-load-bearing steel framing systems for interior gypsum board assemblies. 2. Suspension systems for interior gypsum ceilings and soffits.

GENERAL MECHANICAL SYSTEM REQUIREMENTS

DIRECT-TEMP SELKIRK DIRECT VENT SYSTEM

PROJECT: PREPARED BY: PREPARED FOR: Boiler Breeching and Stack Generator Engine Exhaust Fume Venting Fireplace Venting

Installation Manual Installation and Fireplace Setup

The most versatile "BIG SCREEN" high efficiency fireplace!

BROCHURE # 108 CONSTRUCTION PLAN COMPONENTS

ARTICLE 12 INTERNATIONAL RESIDENTIAL CODE 2012 International Residential Code Modification Summary (Statutory Authority: 1976 Code Section )

Air flue duct for use with ecotec boilers

O B R O U N D G R E A S E D U C T

Sflue. Twin Wall Flue TOVE TOVE. Economical twin wall, insulated stainless steel chimney system for wood burning/multi fuel stoves

SECTION NON--STRUCTURAL METAL FRAMING

Installation Manual Installation and Fireplace Setup

for architects & designers

TYPICAL ROOF CONDITION LAYOUT

Gas Fireplaces. B36XTE Gas Fireplace. Unit Dimensions with Vignette: Model B36XTE-NG10 B36XTE-LP10 M O S S. V Opening for gas connection

SUBMITTAL RECORD. Material Selection FLUE (INNER WALL) CASING (OUTER WALL) GALVALUME

TC30 FOR ARCHITECTS & DESIGNERS SERIES D. Dimensions Clearances Venting

SI T T FSS/FSTT Open Fire

DIRECT-TEMP METALBESTOS DIRECT VENT SYSTEM

InoxSabiana 25 Flues. Stainless Steel Double Wall

Architect & Builder s Guide. ORTAL Heating Systems Ltd.

for architects & designers

Installation Manual Installation and Fireplace Setup

Installation SBIHA-Black single wall pipe

Transcription:

DuraPlus ll-fuel, triple-wall chimney system. UL 103 HT.

Specifications pplications DuraPlus himney is a triple-wall, all-fuel chimney for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas. Materials and onstruction.016 30 stainless steel outer wall or.018 galvanized steel outer wall..018 aluminized steel intermediate liner..016 30 stainless steel inner liner. Insulated layers of ceramic blanket plus ventilated air space. Locks tightly with a precision twist-lock connection. UL 103 HT System DuraPlus DuraPlus is designed to stay cool on the outside, to provide a hot draft on the inside, to boost stove efficiency, and to provide for a fire-safe design that protects both the chimney and the building. This triple-wall chimney features two insulating layers (ceramic blanket, plus air space). The ceramic blanket insulation is held securely in position, eliminating hot spots common with loose-fill type insulations. In the event of a creosote fire, the compressible blanket insulation permits the chimney liner to expand outwardly in a radial direction. learances 2 clearance to combustibles. Diameters 6-8 Listings UL Listed to UL 103HT (MH7399). 9 DuraVent www.duravent.com

ll-fuel himney DuraPlus Typical Installations 8 6 7 9 6 10 5 15 15 2 1 1 8 7 2 Installation Key 1 DVL or Duralack Stovepipe 1 Tee Support racket 2 eiling Support ox 13 Wall Strap 3 Wall Thimble 1 Firestop Radiation Shield DuraPlus himney Snap-Lock dapter, DVL/Duralack himney 15 5 ttic Insulation Shield dapter, Duralack Slip onnector 6 Roof Flashing 16 Extended Roof racket 7 Storm ollar 17 DVL or Duralack himney dapter 8 himney ap 18 DVL or Duralack Tee 9 Elbow 19 DVL or Duralack Elbow 10 Elbow Strap 20 hase Top Flashing 11 Tee with ap 21 nchor Plate 6 3 15 19 ttic Offset 8 7 13 11 7 18 19 athedral eiling Roof Support 8 6 5 2 17 Refer to our Typical Venting Installation drawings to select the appropriate component parts for your installation. DVL/Duralack himney dapter or Duralack Slip onnector must be used when connecting DVL or Duralack stovepipe to a eiling Support, Wall Thimble, or Finishing ollar. Snap-Lock dapter must be used when attaching snap-lock stovepipe to DuraPlus. Wall Thimble must be installed with an appropriate section of chimney pipe for all horizontal through-the-wall installations. To accommodate thicker walls a wall thimble extension can be field fabricated. n ttic Insulation Shield must be used in all installations that pass through an attic, regardless of whether the attic is insulated or not. If chimney is enclosed in a chase in the attic space, an ttic Insulation Shield is not required. Firestop Radiation Shield must be used when a chimney passes through a floor or ceiling without a eiling Support ox. 1 12 1 himney ap Extended Roof racket Storm ollar Flashing Elbow Strap Through-the-Wall 8 6 7 7 Oil Furnace 8 13 Elbow ttic Insulation Shield Firestop Radiation Shield himney Pipe Wall Strap 2 17 1 * 15 Second Floor hase eiling Support himney dapter Duralack Stovepipe or DVL Stovepipe Manufactured Home *DVL stovepipe required for this installation Fireplace (New or retrofit) Stove dapter 800-835-29 DuraVent 50

DuraPlus ll-fuel himney Planning Your Installation 3 FT. MINIMUM HEIGHT FROM ROOF PENETRTION 2 FT. MINIMUM OVE HIGHEST POINT OF ROOF WITHIN 10 FT. 10' MINIMUM HIMNEY HEIGHT REQUIREMENT Figure 1 The following recommendations are a general guideline to assist in the layout and selection of the chimney components needed for your installation. lways follow DuraVent Installation instructions before installing your chimney system(enclosed with the cap or support box). Installation instructions can be viewed online at www.duravent.com, under catalogs and instructions. The diameter of the chimney should match the outlet size of the appliance. n improperly sized chimney results in poor draft and excessive creosote formation. Measure the diameter of the appliance flue outlet. Select the chimney and either DVL or Duralack connector stovepipe with the same size diameter as the appliance flue outlet. For fireplace installations, refer to the sizing chart in the back of the DuraTech section of this catalog. Determine if the installation is a through-the-roof installation or a through-the-wall installation. through-the-wall installation will require additional components (Wall Thimble, Tee w/ ap, Tee Support, and Wall Straps). Install the chimney in the interior of the structure whenever possible. cold exterior chimney will produce less draft and will generate more creosote. If possible, avoid offsets that serve to restrict the natural draft. straight vertical installation is more efficient and less likely to develop creosote. If an offset is required to avoid rafters or other obstructions, measure the horizontal distance required and the vertical height available. oth 15 and 30 elbows are available. Elbows greater than 30 are not allowed in the United States. maximum of two offsets in a single installation are permitted. Refer to the offset table in the back of this catalog. t least one Elbow Strap is required for each offset. Elbow Straps ensure adequate support. Determine the minimum chimney height above the roof line. uilding codes require a minimum of 3 above the roof penetration and at least 2 higher than any portion of a building within 10. See figure 1. The termination cap is installed above that point. If chimney is more than above the roof penetration an Extended Roof racket is required. Measure the roof pitch. For example, a 6/12 pitch has a vertical rise of 6 over a horizontal distance of 12. Select the appropriate flashing. Determine the total length of chimney and stovepipe required for the installation. To calculate the installed per length of 6-8 DuraPlus chimney pipe, subtract 1 1 2 per joint. Subtract 1 1 per joint of Duralack stovepipe. Subtract 1 1 2 per joint of DVL stovepipe. Minimum chimney height, at sea level of straight vertical chimney is 10 to 15 above the appliance outlet. Higher elevations, or the use of elbows or a tee, will require approximately 30% to 60% more height to provide for an adequate draft. e fire safe. Maintain at least 2 clearance to combustibles. Follow local building codes and have your chimney inspected by a certified professional. 51 DuraVent www.duravent.com

ll-fuel himney DuraPlus asic Kit Kit includes: DVL/Duralack himney dapter, Snap-Lock dapter, 11 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and ttic Insulation Shield. Only available in 6 diameter. Pipe not included. an be used for cathedral ceiling installations. Use for typical through-the-roof installations. SIZE 6 STOK # 9085 Manufactured Home Kit Kit includes: DVL/Duralack dapter, 2 Square eiling Support ox with Trim, djustable Flashing 0/12-6/12, himney ap, Storm ollar, and (2) 2 DuraPlus himney Pipe (galvanized). Only available in 6 diameter. an be used for cathedral ceiling installations. Use for manufactured home through-the-roof installations. SIZE 6 STOK # 9086 Through-The-Wall Kit Kit includes: DVL/Duralack himney dapter, Snap-Lock dapter, 9 DuraPlus himney Pipe (galvanized), Wall Thimble, Tee w/ ap, (2) djustable Wall Strap, Tee Support racket, and himney ap. Only available in 6 diameter. Use for through-the-wall installations. SIZE 6 STOK # 9088 800-835-29 DuraVent 52

DuraPlus ll-fuel himney Pipe Selection hart Installed himney Height himney Sections Used Installed himney Height himney Sections Used 6 12 2 36 6 12 2 36 6 1 1-10 1 2 1 5 1' 1 15-1 2 1 5 2' 1 16-1 2 1 5 3' 1 17-1 2 6 3'- 1 2 1 1 17-9 1 6 3'-10 1 2 1 1 18'-3 1 6 '-10 1 2 1 1 19'-3 1 6 5'-10 1 2 2 20'-3 7 6'-3 1 2 20-7 1 2 1 7 6'-9 1 2 21-1 1 2 1 7 7'-9 1 2 22-1 1 2 1 7 8'-9 3 23-1 1 2 8 9'-1 1 2 1 3 23'-6 1 8 9'-7 1 2 1 3 2' 1 8 10'-7 1 2 1 3 25 1 8 11'-7 1 2 26 9 12 1 26-1 2 1 9 12'-6 1 26-10 1 2 1 9 13'-6 1 27-10 1 2 1 9 1'-6 5 28-10 1 2 10 himney Pipe Length Ø Ø Designed for appliances tested and listed for use with wood stoves, fireplaces, furnaces, boilers, stoves, ranges, water heaters, or other appliances fueled by wood, oil, coal, or gas. 6, 9, and 12 chimney pipe has 1 insulation blanket; 2, 36 chimney pipe has 1 2 insulation. To calculate the installed length of DuraPlus chimney pipe, subtract 1 1 2 from each length of chimney pipe. dditional protective carton filler for shipping is available, items have stock numbers with (F). SIZE 6 7 8 6 7 8 10 11 12 LENGTH 6 9006 9106 9206 9 9019 9119 9219 12 901 911 921 2 9021 9121 9221 2 -- -- 9221F 2 SS 9021SS 9121SS 9221SS 2 SS -- -- 9221SSF 36 9017 9117 9217 36 9017F -- 9217F 36 SS 9017SS 9117SS 9217SS 36 SS 9017SSF -- 9217SSF 53 DuraVent www.duravent.com

ll-fuel himney DuraPlus Elbow Kit Kit includes: (2) elbows and one Elbow Strap. Use for offsets around obstructions such as rafters, ridgepoles, or joists. May have two pairs of elbows, if needed. Offsets greater than 30 are not permitted in accordance to UL 103 standards. Elbows swivel 360 at base (angles are not adjustable). pair of elbows is required to return an offset chimney back to vertical. vailable in stainless steel (SSKIT) or galvalume (KIT) outer wall. 15 STOK # 6 906KIT 3 3 6 906SSKIT 3 3 7 916KIT 1 1 8 7 916SSKIT 1 1 8 8 926KIT 1 1 8 926SSKIT 1 1 30 STOK # 6 9066KIT 1 2 3 6 9066SSKIT 1 2 3 7 9166KIT 5 8 3 7 9166SSKIT 5 8 3 8 9266KIT 5 3 8 9266SSKIT 5 3 Elbow Strap Ø Use to prevent excessive weight on the elbows by supporting the weight of the chimney. Required to be installed between two elbows in offset installations. Multiple elbow straps may be required for offset installations. Refer to installation instructions. 2 SIZE 6 7 8 10 11 12 STOK # 9060 9160 9260 Round eiling Support 18 1 3 18 Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Supports up to 35 of DuraPlus himney. Use adapter to attach DVL or Duralack to the support box. Painted black. Trim collar included. (For adapters see DVL/Duralack section.) SIZE 6 7 8 STOK # 905N 915N 925N 800-835-29 DuraVent 5

DuraPlus ll-fuel himney Square eiling Support ox 18¼ 1¼ Use with flat, vaulted, or cathedral ceilings. Square eiling Support ox is painted black. Refer to eiling Pitch table to determine size of support box needed. Supports up to 35 of DuraPlus himney. Starter Section built in. For adapters, see DVL/Duralack section. Trim included. SIZE STOK # 6 908N 11 6 908N 2 6 908DN 36 7 918N 11 7 918N 2 7 918DN 36 8 928N 11 8 928N 2 8 928DN 36 EILING PITH DURLK DVL USE 0/12 - /12 0/12-6/12 11 Support box 5/12-9/12 7/12-13/12 2 Support box 10/12-1/12 1/12-20/12 36 Support box Flat eiling Support ox " Supports chimney pipe and provides a positive connection between support box and chimney with a built-in twist-lock. Designed for installation in flat ceilings only. Supports up to 35 of DuraPlus chimney pipe. Use adapter to attach DVL or Duralack to the support box. 2 wide trim collar is included. Not painted, but can be painted with high temperature paint. For adapters, see DVL/Duralack section. SIZE STOK # 6 907N 6 1 1 1 7 917N 7 1 1 1 8 927N 8 1 1 1 Wall Thimble 17 17 Ø1 ¾ -7¾ djusts from a minimum of 3 to a maximum of 7 3 wall thickness, and fits between standard wall studs. To accommodate thicker walls, the telescoping pieces can be extended up to 16 with a field-fabricated extension installed. Interior trim ring painted black. Must be installed with DuraPlus chimney pipe horizontally through the wall and extend a minimum of 2 into the room beyond the interior wall. For adapters, see DVL/Duralack section. SIZE STOK # 6 903N 6 903SS 7 913N 7 913SS 8 923N 8 923SS WHEN USING WLL THIMLE WLL THIKNESS INSTLL PIPE SETION 1 2 6 1 2-5 1 2 9 5 1 2-8 1 2 12 8 1 2-13 (2) 9 55 DuraVent www.duravent.com

ll-fuel himney DuraPlus Tee w ap Use for through-the-wall chimney installations. The tee cleanout cap is removable for easy chimney cleaning or inspection. Wall Straps, a Wall Thimble, and a Tee Support must be installed with the Tee as directed. Tees have 1 insulating blanket. Ventilation air for chimney must be drawn from outdoors. (See installation instructions.) SIZE STOK # 6 9067 13 7 8 7 1 2 8 1 6 9067SS 13 7 8 7 1 2 8 1 7 9167 15 3 8 8 8 3 7 9167SS 15 3 8 8 8 3 8 9267 16 8 1 2 9 8 9267SS 16 8 1 2 9 Tee Support racket Use to support the Tee; suspended from a wall. Supports up to 35' of DuraPlus himney. Starter Section built in. SIZE STOK # 6 9072 10 1 12 6 9072SS 10 1 12 7 9172 11 15 13 7 9172SS 11 15 13 8 9272 12 16 1 8 9272SS 12 16 1 djustable Wall Strap 2-6 Use in interior or exterior installations to support and to stabilize the chimney while assuring a 2 clearance. Wall straps are required every 8' on exterior of building. djusts 2-6 from wall. 2 Ø SIZE STOK # 6 9069 10 16 1 8 7 9169 11 17 1 8 8 9269 12 18 1 8 800-835-29 DuraVent 56

DuraPlus ll-fuel himney Wall Strap 2" 2" DuraPlus Wall Strap Use in interior or exterior installations to support and to stabilize the chimney while assuring a 2 clearance. Wall straps are required every 8 on exterior of building only. SIZE STOK # 6 9068 10 16 6 9068SS 10 16 7 9168 11 16 7 9168SS 11 16 8 9268 12 16 8 9268SS 12 16 ase Plate Use to adapt on a zero-clearance fireplace when using DuraPlus directly off the unit. Starter Section built in. " 12" 12" 1" SIZE STOK # 6 9001 6 10 7 9101 7 11 8 9201 8 12 Transition nchor Plate Ø Ø D 17/16 Use Transition nchor Plate with DuraPlus when extending or converting from DuraLiner to DuraPlus in chimney restoration. Use with DuraLiner Slip onnector and Hanger. (See DuraLiner section.) SIZE STOK # D 6 900 6 1 16 10 3 8 17 1 6 900 6 1 16 10 3 8 17 17 6 900 6 1 16 10 3 8 21 13 6 900D 6 1 16 10 3 8 21 17 8 920 8 1 16 12 3 8 17 1 8 920 8 1 16 12 3 8 17 17 8 920 8 1 16 12 3 8 21 13 8 920D 8 1 16 12 3 8 21 17 57 DuraVent www.duravent.com

ll-fuel himney DuraPlus Starter Section Ø " Use only when converting from DuraLiner to DuraPlus and the DuraPlus himney is going to be enclosed in a chase. (See DuraLiner installation instructions.) SIZE STOK # 6 9011 6 10 8 9211 8 12 Firestop Radiation Shield 6" 10" Use in ceiling/floor penetrations when a ceiling support is not used. Not required when passing through the roof. Fits on underside of ceiling and adjusts to cover framing. See installation instructions for proper placement. SIZE STOK # 6 90 10 3 16 10 7 8 16 1 2 7 91 11 3 16 11 7 8 16 1 2 8 92 12 3 16 12 7 8 16 1 2 ttic Insulation Shield Required for installations that pass through an attic to prevent insulation and debris from accumulating near the chimney. Fits over Firestop Radiation Shield or a support box. onsists of two parts: a collar and a base. SIZE STOK # 6-8 996 10, 11, 12 1 ¼ 20 10" aplus ttic Insulation Shield lose learance Shield Rafters on 16" enters 1" 1" Use in installations where a 7 or 8 Simpson Dura-Vent chimney system passes through a roof opening with less than the normal 2 minimum clearance to roof trusses or rafters. himney pipe must be centered within lose learance Shield. (See installation instructions.) SIZE STOK # 6-8 9980 36 6-8 9980 8 6-8 9980 60 800-835-29 DuraVent 58

DuraPlus ll-fuel himney Roof Flashing Use to weather proof the penetration of chimney pipe through the roof. Storm ollar required. Select roof flashing based on pitch of roof. For example, a 6/12 pitch has a vertical rise of 6 over a horizontal distance of 12. Made of galvalume. D SIZE 6 7 8 10 ¾ 10 ¾ 11 10 1 2 11 ¾ 12 ¾ FLT ROOF 26 29 ½ 29 1 2 D 26 29 1 2 29 1 2 STOK # 9051V 9151V 9251V 6 6 6 0/12-6/12 PITH 10 ¾ 11 ¾ 12 ¾ 26 26 26 D 28 28 28 0/12-6/12 STOK # 909V 919V 929V 7/12-12/12 STOK # 9050V 9150V 9250V 13/12-18/12 STOK # 9081V 9181V 9281V 19/12-2/12 STOK # 9052V 9152V 9252V DS Roof Flashings Use with metal or tile roofs. vailable in sizes 6 and 8, in 0/12-6/12 (shown) and 7/12-12/12 styles. Made of dead soft aluminum. Refer to Roof Flashing table for dimensions. SIZE 6 8 0/12-6/12 909DS 929DS 7/12-12/12 9050DS 9250DS Storm ollar Required with DuraPlus flashing to create a weather proof penetration through the roof deck. Seal inner edge of the collar to the chimney pipe with non-hardening 500 F high-temperature sealant. SIZE 6 7 8 10 11 12 13 1 15 STOK # 9959 59 DuraVent www.duravent.com

ll-fuel himney DuraPlus Extended Roof racket Use to support the chimney when it extends more than above the roof. Provides stability to chimney against wind and snow. Mounting brackets and adjustable legs included. Ø SIZE 6 7 8 10 11 12 STOK # 9061 9161 9261 67-11 himney ap 2¼ 15 Ø Required where chimney pipe terminates above the roof line. Removable screws allow for cleaning of the chimney and spark arrestor screen. Made of stainless steel. SIZE 6 7 8 6 7 8 12 13 1 7 8 8 STOK # 908 918 928 hase ir Intake w Rodent Guard llows required ventilation air into chase. Screen keeps rodents out. SIZE 6 STOK # 168 NEW Snow Splitter 23 25 Use to divert snow around chimney, vent, and roof flashing. onstructed of paintable galvanized material. Ships flat for easy assembly. SIZE 6 STOK # 993 800-835-29 DuraVent 60

DuraPlus ll-fuel himney Offset hart OFFSET RISE Elbow Degrees SIZE 6 DIMETER 7 DIMETER 8 DIMETER himney Section Offset Inches Rise Inches Offset Inches Rise Inches Offset Inches Rise Inches 15 0 1 1 2 12 1 3 13 1 2 1 3 15 1 15 6 2 3 18 3 19 3 8 3 19 1 2 15 9 3 1 2 21 3 3 22 1 3 3 22 1 2 15 12 3 8 2 1 2 25 1 8 1 2 25 1 2 15 2 7 1 2 35 1 2 7 3 36 3 7 1 2 37 15 36 10 1 2 7 10 3 8 1 2 10 3 8 1 2 15 2 +2 13 1 57 1 13 1 2 58 1 2 13 1 2 58 3 30 0 3 3 16 3 3 1 1 3 3 1 3 30 6 6 20 6 20 6 1 2 20 3 30 9 7 1 2 22 1 2 7 1 2 22 3 8 23 1 30 12 9 25 9 2 9 2 30 2 15 35 1 2 15 35 3 15 1 36 1 30 36 21 5 3 21 6 21 1 6 3 30 2 +2 26 3 8 5 3 26 1 2 55 26 3 55 3 himney Sizing hart For Fireplace Installations HIMNEY HEIGHT (FEET) 50 T 0 30 20 8 1015 2 22 20 18 T 16 1 12 10 8 7 FIREPLE OPENING (INHES) 8 72 60 W 8 2 36 30 2 8 2 36 30 2 20 18 WIDTH 18 72 8 60 H HEIGHT 6 H W Dotted line represents sample problem. Example shows fireplace opening as 36 wide and 30 high, and the chimney height as 20. The correct flue size for the sample problem is 12 diameter pipe. 61 DuraVent www.duravent.com