GIBERTINI OP150S. User manual. Installation Guide GIBERTINI. Supporto AZ/EL per parabole Ø 150 mm AZ/EL support for satellite dishes of Ø 150 mm

Similar documents
GIBERTINI OP125L. User manual. Installation Guide GIBERTINI. Supporto AZ/EL per parabole Ø 120 mm AZ/EL support for satellite dishes of Ø 120 mm

TIER I ANTENNA FEED SYSTEM

" RISKS ASSOCIATED WITH THE INSTALLATION OF THE SYSTEM

.89/.98M Ku-BAND Rx/Tx SERIES 1892/1982 ANTENNA SYSTEM

1.2M Ku-BAND Rx/Tx SERIES 1135 FEED SYSTEM

Model m x 1.98 m NPRM with Roof Pads For 1.2 m Antenna Systems

Fitting and Operating Instructions

MOUNTING SYSTEM FOR PITCHED ROOF WITH TILES. mounting system for pitched roof with tiles for solar panels in landscape setup. Rev

MANUAL MOUNTING SYSTEM FOR BITUMEN / EPDM

SECURE. UNIVERSAL. MOUNTING. Tilt Kit Installation Manual

SECTION 716 SIGN MATERIALS SCOPE

MANUAL HALLSYSTEM COPYRIGHT 2016 SAFETYRESPECT AB Art no ENG

User instructions for photovoltaic modules 60Pxxx-V 60Mxxx-V 72Pxxx-V 72Mxxx-V 60Pxxx 60Mxxx 72Pxxx 72Mxxx

MANUAL. landscape orientation. portrait orientation. metal roof mounting system for solar panels METAL ROOF MOUNTING SYSTEM. Rev

PROFESSIONAL SOUND SYSTEMS WPB OPERATING MANUAL AND USER GUIDE. WPB User Manual.indd :21:39

ITEM 686 TRAFFIC SIGNAL POLE ASSEMBLIES (STEEL)

ASSEMBLY INSTRUCTIONS

Mounting systems for solar technology

NORMACONNECT Pipe Connections

Coating Specifications

Clenergy ezrack SolarRoof Code-Compliant Planning and Installation With Australia AS/NZS1170

DIN 3015 CLAMPS B1-1 PN# / / ACC

DPA Solar Racking Solutions Ground Mount Installation Guide V1.5

2-Finger-Parallel-Gripper RH

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

Connectors. Multi-purpose connecting clamps. Stainless steel cross connectors

TD TD

INSTALLATION MANUAL. METAL INSULATED PANELS -ROXUL -Expanded Polystyrene

TRITEC light Steel Panel Formwork

Mounting systems for solar technology

Aluminium hinges Aluminium hinges Further materials and surface finishes on demand. We will be pleased to give you advice.

Radiant Solar Tripod Planning and Installation Guide V1.2 With Australia AS/NZS1170.2

Preparation and Installation of the FA, FAV, and FAS Type Rupture Discs in Forward Acting Insert, Full Bolted, and Union Type Holders

The Atlas Electric Industries Pvt. Ltd.

SF70-1EH SF45 TRACKERS FEINA

Z5351 E8 Horizontal bracket Mounting instructions (1.1 EN)

PE45 AMAZON MONKEY BARS OWNER'S MANUAL

Technical Specification for Live Line Tap Connectors

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Luna - design arch. Valenti

CANTILEVER IPE

Modular Scaffolding MEKA 48

PYROS. Código: FT-PY01-I Revisión: 1 1. TECHNICAL DATA. Polycarbonate tube of 4 mm. thickness LIGHT FITTING. Laquered steel painted white REFLECTOR

LK15 PRESTIGE PLAY KITCHEN OWNER'S MANUAL

VAREC SERIES 2010B/2020B/3500B PRESSURE AND VACUUM RELIEF VALVE INSTRUCTION, OPERATION AND MAINTENANCE MANUAL

ZINC FLAKE COATING SYSTEMS

ASSEMBLY AND OPERATING MANUAL LTW SHORING BOXES VB 100

Fitting and Operating Instructions

SPECIFICATION SS-20 / 4 STEEL STRUCTURES FOR SUBSTATION AND SWITCHING STATION MATERIAL

ArenaVision LED gen2 Floodlight

20 Portable Saw Mill OWNER S MANUAL

markilux RS-2 More free space, opening up boundless possibilities INNOVATIONS 2017 rated to wind resistance class 3 (corresponds to Beaufort 6)

24 Portable Saw Mill OWNER S MANUAL

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

Concrete screw BSZ Steel/steel zinc flake coated

Recommended Land Pattern: [mm] Stencil Suggestion:

Recommended Land Pattern: [mm] Stencil Suggestion:

Troubleshooting Guide 9702 Series

ASSEMBLY AND OPERATING MANUAL LTW SLIDE RAIL SYSTEM - Type PV

06/2010 Technical Manual MESA - KSK. Gable Platform System for Exterior Operations

Huck Seiltechnik GmbH Aßlar/Berghausen Germany

blu stone freestanding basins Installation Guide

FRP LADDERS MM06 FRP LADDERS Rev. 3 COMPOSITE SOLUTION PAGE 1

Conergy SolarFamulus II

Replace This With Cover PDF

A-Series Aluminum Gantry Crane

Safety Barrier Solutions

Mod. Dynamic Double hide-away bed system

Sub-construction for Wall-mounted Longlight

CEILING MOUNTED ARTICULATING JIB CRANE

Think Safety, Think Safesite O&M - KEEGUARD

Materials Carbon Steel is used in the manufacturing of riser and pipe clamps. Stainless Steel and other materials are available.

Mounting systems for solar technology ASSEMBLY INSTRUCTIONS. S-Dome 2.0 System.

PITCHED ROOF. Photovoltaic Mounting Systems. Assembly Instructions. for roofing tiles, plain tiles and slate

Fig Beam Clamp Retaining Strap (B-Line B3367)

City of Minot Auditorium Non-Upholstered Arena Seating Specifications

Approaching towards innnovation. An ISO 9001:2015 Certified company

Essex County College - West Essex Campus Addition And Renovations dlb # / SECTION CABLE TRAYS FOR COMMUNICATIONS SYSTEMS

TRAPEZOIDAL SHEET METAL RAIL LIFT/VARIO for trapezoidal sheet metal roofs

Bottom last using FW 1850 and TSBL types: 1st movement: both sets of ejector plates, 2nd movement: bottom set of ejector plates.

BOURNEMOUTH planter. Street Design Limited Unit 35 Hayhill Industrial Estate Barrow upon Soar Leicestershire LE12 8LD

Installation Instructions TrafficLED Levelling Console

SPORTSBEAMS 1500 LED USER MANUAL SPORTSBEAMS LIGHTING, INC. v.1.0

Modular Scaffold MEKA 48

EIV. Circular single deflection grille for walls. Quick facts. Quick guide EIV A I R F L O W - S O U N D L E V E L

Z5554 Mounting instructions 1.1 en

Mounting systems for solar technology

Z5377 E6 Swivel bracket Mounting instructions (1.2 EN)

DURA-BLOK is made from 100% recycled rubber and qualifies for LEED credits. Reflective strips on both sides allow for easy product visibility.

B Recommended land pattern: [mm] C Stencil suggestion: SSt SSt CHECKED DATE

Design and Analysis of Antenna Reflector Using Composite Materials

OKAPOINT Point Supported Insulating Glass

SECTION SHOWER AND DRESSING COMPARTMENTS

Protective Capony RTC-16

B Recommended land pattern: [mm] C Stencil suggestion: SSt. SKl CHECKED DATE

ArenaVision LED gen2 Floodlight

STRUT METAL FRAMING SYSTEMS

DATASHEET: FIRECUT F-1 (EXTERIOR) SPRAY-APPLIED FIRE RESISTIVE MATERIALS

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

Sentinel Direct Fix Deepflow Gutter

Transcription:

Supporto AZ/EL per parabole Ø 150 mm AZ/EL support for satellite dishes of Ø 150 mm art. 11-136 SUPP. AZ/EL G TECHNICAL SPECIFICATIONS OP150S Frequency range (GHz) 10.00-13.00 Feed illumination angle 70 Outside dimension (cm) 155.0 x 166.0 Feeder clamp (mm) 40 / 23 Reflecting dimension (cm) 150.0 x 161.0 Elevation angle 20-90 Illumination efficiency * (%) 70 Gain * @ 10.70 GHz (dbi) 43.00 Mast clamp (mm) 55-100 Gain * @ 11.70 GHz (dbi) 43.70 Alu reflector thickness (mm) 2.0 Gain * @ 12.75 GHz (dbi) 44.50 Steel reflector thickness (mm) not available Cross polarization * on axis (dbc) - 28 alu 23,8 Antenna net weight (kg.) First side lobe level * (dbc) - 25 steel n. a. Noise temp. * @ 12GHz, 36 elevation (K) 31 Wind load @ 120 km/h (kg) [worst-case] 250 F/D radio 0.66 Working temperature - 30 / + 70 3dB Beam width* @ 11.7GHz 1.07 Humidity 0 100% Offset pointing angle 21.3 WARNINGS We strongly encourage you to read this manual before installation and use of the product and strictly observe the recommendation hereof. v.11.14 OP150S satellite offset antenna Ø 150cm - - - Installation Guide - The producer pag. 1

CONTENTS OF THE PACKAGE n 1 RL150A n 1 SCC150 Reflector Refector support n 1 SPL125 n 1 SCL125 n 1 SB125 n 1 SD125-HR Pole Clamp components Elevation bracket pag. 2

CONTENTS OF THE PACKAGE n 1 SIN-150 n 1 SSCPAP n 1 TRL150FC n 1 TRL150FL n 1 SA150F Arms and Feed Holder mount components BERTINI n 2 TTL150 Side rods pag. 3

CONTENTS OF THE PACKAGE Elements and thread parts 1 for Pole mount clamp w Elements and thread parts for the Elevation bracket and reflettor support n 2 M8x20 - ISO 4017 - UNI 5739 - DIN933 n 4 Ø6 - ISO 7089 - UNI 6592 - DIN125A n 6 M8 - ISO 4033 - UNI 5587 n 4 Ø8 - ISO 7089 - UNI 6592 - DIN125A n 6 Ø8 - DIN 6798A - UNI8842A n 4 M6x45 - ISO 4017 - UNI 5739 - DIN933 n 6 Ø8 - ISO 7089 - UNI 6592 - DIN125A n 4 M8x20 - ISO 4017 - UNI 5739 - DIN933 n 2 M8 - [VTM8380I] 3 Elements and thread parts for Elevation adjuster 4 Elements and thread parts for Bracket and pole mount unit assembly n 2 M8 - ISO 4033 - UNI 5587 n 3 M8 - ISO 4033 - UNI 5587 n 2 Ø8 - DIN 6798A - UNI8842A n 3 Ø8 - DIN 6798A - UNI8842A n 1 M8x40 - ISO 4017 - UNI 5739 n 2 Ø8 - ISO 7089 - UNI 6592 - DIN125A n 1 L=20 - [YVD20G] n 1 [VHIPID] n 1 L=175 - [VPO175I-PR] n 3 M8x170 - ISO 4014 - UNI 5737 - DIN931 n 1 [SB120] n 1 [VB140] TINI pag. 4

CONTENTS OF THE PACKAGE 5 Elements and thread parts for Arms and feed holder mount 6 Elements and thread parts for Antenna reflector n 5 M6 - ISO 4032 - UNI 5588- DIN934 n 6 M6 - ISO 10511 - DIN 985 - UNI7474 n 5 Ø6 - DIN 6798A - UNI8842A n 6 M6x12 - ISO4762 n 5 Ø6 - ISO 7089 - UNI 6592 - DIN125A n 1 M6x45 - ISO 4017 - UNI 5739 - DIN933 n 2 M6x50 - ISO 4017 - UNI 5739 - DIN933 n 2 M6x70 - ISO 4017 - UNI 5739 - DIN933 n 1 CHBR4 7 Elements and thread parts for Antenna reflector n 1 M6 - ISO 4032 - UNI 5588- DIN934 n 1 Ø6 - DIN 6798A - UNI8842A n 1 Ø6 - ISO 7089 - UNI 6592 - DIN125A n 1 M6x45 - ISO 4017 - UNI 5739 - DIN933 n 2 M6 - ISO 10511 - DIN 985 - UNI7474 n 2 M6x12 - ISO4762 ERTINI pag. 5

ASSEMBLING STEPS 1 Assembly of the pole clamp mount - 2 Assembly of the Elevation bracket to the reflector support 3 Assembly of the Elevation fine regulation threaded tie-rod

ASSEMBLING STEPS 4 Assembly of the antenna rear bracket to the pole clamp mount 5 Assembly of arms and feed holder assy - - OK NO -

ASSEMBLING STEPS y Assembly of the antenna reflector on the bracket assy. BERTINI

ASSEMBLING STEPS u Assembly of side rods IBERTINI

Installation All GIBERTINI the dishes Antennas are manufactured are manufactured using using well certified well certified materials and and assembly components that ensure a a reliable and and long long life product. life product. During installation, for proper use and safety, screws and bolts have to be used in proper indicated place without exchange in position (e.g. do not use a M4 bolt where an M6 is foreseen). The personnel in charge of installation will be the sole responsible of the pole fixation on roof or wall, and have to take care of the proper tightening between antenna components. If not elsewhere indicated, the following table report the recommended tightening torque, in Newton * meter, to be applied on different mechanical couplings. Thread size Tightening Torque Bolt/Nut assembly Tightening Torque Bolt/Insert assembly pitch min [Nm] max [Nm] min [Nm] max [Nm] M3 1.1 1.5 0.7 1.1 M4 2.2 3.1 1.5 2.2 M5 4.2 6.0 2.9 4.2 M6 7.3 10.4 5.1 7.3 M8 17.1 24.4 12.0 17.1 M10 35.1 50.1 24.5 35.1 Maintenance Plan All GIBERTINI the dishes Antennas have shown have shown good good durability durability even even in worst in worst conditions, provided than that no no permanent demages damages to plating or painting have been procured during the installation or due to to other origins after installation. Nevertheless, a periodic maintenance enforce the warranty validity and help in order to elongate the life of the assembly. Period General care Paint Zinc plating Every two years or in case of storm wind and/or strong hailstorm Verify the integrity of the antenna assembly. Clean with a conventional duster the dish surface and the LNB feed -do not use solvents for normal cleaning- dry cleaning is normally enough, use water or alcohol to remove solid attached elements, dry with a cloth. If the painting has been ruined, remove gently the rust, if present, using a fine abrasive paper (type 00), then clean with acetone, chloroform or similar oil free solvent, dry and than repaint with two pass of -water based- opaque paint of the proper RAL. (Conventional paint used in car repair. Please refer to the paint Manufacturer recommendations for the latency time between the painting). Chemical solvents are flammable and volatile : do not expose directly, protect with mask and gloves. Use only opaque paints. Brilliant paints can over heat the LNB cooking it with permanent damages. If damaged due to environmental corrosion, zinc plating can be restored with a chemical zinc spray (ZINK TK0105 by TEKNICA -Italy- or similar products from other Manufacturers like TALKEN, etc.). Using a metallic brush remove oxidation and rust if present, clean with acetone, chloroform or similar oil free solvent and live it to dry. Apply one or two pass of spray zinc, having care to cover uniformly all the exposed surfaces (this apply specifically the clamp brackets). Carefully follow the indications of the spray zinc Manufacturer. The spray contain Toluene: flammable, do not expose to fire, do not smoke, do not dry with direct flame or hot air irons at temperature higher than 80 C. Vapors can cause irritation and narcotic effects, protect with mask and gloves.