5 6 8 9 1 10 15 SOFFIT OUTSIDE CORNER 16 18 19 12 OPENING 11 END WALL INSIDE CORNER 17 1 7 5 6 ELEVATION FOR DETAIL REFERENCE ONLY IWV-01 IWV-02 IWV-0 IWV-0 IWV-05 IWV-06 IWV-07 IWV-08 IWV-09 IWV-10 INDEX STANDARD PANEL OFFERING SIDE LAP DETAILS WALL SECTIONS WALL SECTIONS WALL SECTIONS BASE DETAILS PARAPET DETAILS END LAP DETAILS HEAD OPENING DETAIL IWV-11 SILL OPENING DETAIL IWV-12 JAMB OPENING DETAIL IWV-1 HEAD, JAMB, SILL INTERSECTION IWV-1 END WALL DETAIL IWV-15 SOFFIT DETAILS IWV-16 OUTSIDE CORNER DETAIL IWV-17 INSIDE CORNER DETAIL IWV-18 PENETRATION (1 of 2) IWV-19 PENETRATION (2 of 2) INDEX NOTE: DETAILS ARE FOR PROMOTIONAL USE ONLY. FOR COMPLETE DETAILS, REFER TO CENTRIA'S WEB SITE AT www.centria.com IWV-01
[05] [05] 1 1 2 " [8] 1 1 2 " [8] " 6" [152] " [05] IW-10A [05] IW-11A " 1 2 " " 1 1 2 " [8] 1 1 2 " [8] [96] [11] [96] [05] IW-12A [05] IW-1A 6" [152] 6" [152] 1 1 2 " [8] " " " " 1 1 2 " [8] [05] IW-1A [05] IW-15A 6" [15] [05] 6" [15] IW-20A 1 1 2 " [8] " 6" [15] " 6" [15] IW-21A [05] " " 1 1 2 " [8] 2" [9] 10" [256] IW-0A [05] 1 2 1 " [8] 2" [9] " " [102] 10" [256] IW-1A [05] " 1 2 1 " [8] 1" [2] 11" [281] IW-0A 1 2 1 " [8] 1" [2].667 [9].667 [9] 11" [281] IW-1A.667 [9] 1 2 1 " [8] IWV-02 Jan. 1
NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL [05] NOMINAL COVERAGE NON-CURING BUTYL IW-10A, IW-11A, IW-12A, IW-1A, IW-1A, IW-15A 6" 2" 1 1 2 " 11 2 " 11 2 " 11 2 " IW-20A, IW-21A IW-0A, IW-1A [05] NOMINAL COVERAGE 1" SIDE LAP DETAILS IW-0A, IW-1A IWV-0
DRAINED & VENTED CAVITY IW SERIES PANEL INTERIOR SHEATHING STUD INSULATION EXTERIOR SHEATHING HORIZONTAL /" [19] DEEP 16 GA. SUBGIRT BARRIER PANELS ON PROTECTED EXTERIOR SHEATHING WITH CAVITY INSULATION VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. DRAINED & VENTED CAVITY IW SERIES PANEL HORIZONTAL 1/2" [1] DEEP 16 GA. SUBGIRT HORIZONTAL GIRTS BARRIER (PROVIDED BY FACE PANEL) VERTICAL LINER PANEL WITH FACTORY APPLIED SEALANT AIR BARRIER (LINER PANEL) FIELD-APPLIED (1.65 PCF) INSULATION IN LINER CAVITY PANELS WITH INSULATION IN VERTICAL LINER IWV-0 Aug. 11
IW SERIES PANEL " DRAINED & VENTED CAVITY "A" "A" METALWRAP INSULATED BACK-UP PANEL METALWRAP INSULATED BACK-UP PANEL METALWRAP CONT. ZEE AT EACH PANEL SIDE JOINT (6" O.C.) IW SERIES PANEL SECTION A-A PANELS WITH METALWRAP INSULATED BACK-UP PANEL DRAINED & VENTED CAVITY IW SERIES PANEL INTERIOR SHEATHING STUD CON'T. HORIZONTAL ZEE 16 [1.52] GA. MIN. (SPACING TO BE DETERMINED BY CLADDING ENGINEER) EXTERIOR SHEATHING BARRIER INSULATION SUITABLE FOR MOISTURE EXPOSURE PANELS WITH INSULATION OUTBOARD OF STUD CAVITY VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. IWV-05 Aug. 11
MASONRY FASTENER (*) CONTINUOUS HORIZONTAL ZEE SHAPED SUBGIRT (SHIM AS REQUIRED) (*) SUBGIRTS SHALL BE 1.) 16 GA. MINIMUM. 2.) /" [19] MINIMUM DEPTH..) SPACED AT 2" [610] OR 8"O.C. [1219] BASED ON DESIGN LOADS AND INSULATION SIZE. MASONRY INSULATION SUITABLE FOR MOISTURE EXPOSURE AIR BARRIER & WATER RESISTANT COATING OR MEMBRANE IW SERIES PANEL DRAINED & VENTED CAVITY PANELS WITH INSULATION OVER MASONRY WALL VAPOR RETARDER LOCATION THE LOCATION OF THE VAPOR (DIFFUSION) RETARDER IS NOT IDENTIFIED IN THIS DETAIL BECAUSE IT IS A REQUIREMENT THAT VARIES BY CODE JURISDICTION, CLIMATE AND INTERIOR CONDITIONS. THEREFORE THE BUILDING DESIGNER MUST MAKE THIS DETERMINATION. IW SERIES PANEL HORIZONTAL GIRTS FINISH IS REQUIRED ON BOTH SIDES OF THE PANEL SINCE BOTH SIDES ARE EXPOSED TO THE WEATHER PANELS USED AS A SCREEN WALL IWV-06 Aug. 11
EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRT DESIGN OF BASE MUST VARY TO SUIT CONCRETE PLACEMENT AND FORMING TOLERANCES STUDS EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRT 1 8 "[] GAP 1"[25] B/FLASH "± 1 " 1 8 "GAP T/CURB BASE DETAILS IWV-07
F/PNL 5 SLOPE 2"[51] MIN. NON-CURING BUTYL METAL CLOSURE AS REQUIRED EXTERIOR SHEATHING STUDS BARRIER " [19] SUBGIRT PARAPET IWV-08 Aug. 11
EXTERIOR SHEATHING BARRIER AND AIR BARRIER 2"[51] SWAGE NBC NON-CURING BUTYL " [19] SUBGIRT END LAP NOTE: 1.) SHOP SWAGED ENDS ARE NOT AVAILABLE FOR 18 GAGE [1.19MM] PANELS. 2.) SHOP SWAGED ENDS ARE NOT AVAILABLE FOR IW-12A, IW-1A, AND IW-15A. IWV-09
EXTERIOR SHEATHING BARRIER SELF ADHERING TAPE " [19] SUBGIRTS STUDS DOOR, WINDOW OR LOUVER PRIMARY AIR SEAL 1 8 " [] GAP WEATHER SEAL HEAD OPENING IWV-10
T/PNL 1/2" [1] CLR. STUDS " [19] SUBGIRT EXTERIOR SHEATHING METAL CLOSURE AS REQUIRED BARRIER SILL OPENING IWV-11
STUDS BARRIER AND AIR BARRIER EXTERIOR SHEATHING R.O. BARRIER PRIMARY AIR SEAL PER MANUFACTURER RECOMMENDATIONS CURING BUTYL DOOR, WINDOW OR LOUVER WEATHER SEAL /" [19] SUBGIRT 1 1/2" DEEP SUBGIRT (SG-150-18) JAMB OPENING IWV-12 Aug. 11
INTERSECTION OF HEAD, JAMB & SILL FLASH (IWHZ-2016) IWV-1
BARRIER AND AIR BARRIER STUDS EXTERIOR SHEATHING "[19] SUBGIRT SELF ADHERING TAPE 1 1/2" DEEP SUBGIRT (SG-150-18) POLYURETHANE 1 2 " [1] F/CONC. END WALL IWV-1
SELF ADHERING TAPE " [19] SUBGIRT EXTERIOR SHEATHING BARRIER NON-CURING BUTYL @ IW-10A OR CLOSURES @ IW20,0, &0 1/2" [1] E/PNL CLR. SOFFIT - FRONT NON-CURING BUTYL @ IW-10A OR CLOSURES @ IW20,0, &0 E/PNL 1" [25] CLR. NO CLOSURE @ IW-10A & METAL CLOSURE@ IW20,0, &0 " [19] SUBGIRT EXTERIOR SHEATHING BARRIER SOFFIT - BACK IWV-15
BARRIER AND AIR BARRIER EXTERIOR SHEATHING STUDS " [19] SUBGIRT USE A /16"[5]x"x" SHIM UNDER MALE LEG OF PANEL AT EACH FASTENING POINT TO MAINTAIN ALIGNMENT OF PANEL FACE (IF REQUIRED). SG-150-16 SUBGIRT CONTINUOUS (TYP.) OUTSIDE CORNER IWV-16 Jan. 1
BARRIER AND AIR BARRIER EXTERIOR SHEATHING SG-150-16 SUBGIRT CONTINUOUS (TYP.) STUDS " [19] SUBGIRT USE /16"[5]x"x" SHIM UNDER MALE LEG OF PANEL AT EACH FASTENING POINT TO MAINTAIN ALIGNMENT OF PANEL FACE (IF REQUIRED). INSIDE CORNER IWV-17 Jan. 1
NOTE: REF. PAGE IWV-19 FOR SECTS. A-A & B-B PENETRATION DETAIL (1 OF 2) IWV-18 Jan. 1
G.L. NON-CURING BUTYL FLAT SUPPORT FLASH SECTION A-A SUPPORT FLASH FLAT POLYURETHANE (TYP. ALL AROUND) SECTION B-B PENETRATION DETAILS (2 OF 2) IWV-19