CyFlow Space. Your Flexible Flow Cytometer.

Similar documents
CyFlow Space Your flexible flow cytometer

CyFlow Space Your flexible flow cytometer

CyFlow Cube series Appealing from every angle

CyFlow Cube 6. Immunology Microbiology Industrial Applications Agrosciences Aquaculture. Flow Cytometry: Simply elegant. Elegantly simple.

BEYOND A BETTER BOX DI-60 INTEGRATED SLIDE PROCESSING SYSTEM. Seamless Integration

BEYOND A BETTER BOX XN-SERIES TM AUTOMATED HEMATOLOGY SYSTEMS. Reshaping Compact Automation

BD FACSMelody. Cell Sorter. The simple solution for consistent, quality results

Application Note. Yeast Analysis with a life - dead staining kit (Yeast control - viability)

Reshaping compact automation

Reshaping compact automation

A MANAGED APPROACH TO CONTINUOUS PEAK PERFORMANCE

BEYOND A BETTER BOX XN-V SERIES TM MULTISPECIES HEMATOLOGY ANALYZERS. Accelerate Your Multispecies Research Laboratory XN-V IS FOR ANIMAL USE ONLY

BEYOND A BETTER BOX XN-9000 AUTOMATED HEMATOLOGY SYSTEMS. Reshaping Scalable Automation

Principles of flow cytometry: overview of flow cytometry and its uses for cell analysis and sorting. Shoreline Community College BIOL 288

CyFlow ML CyFlow space

PowERFUL. INTUITIvE. customizable. ThE NEw STAR of. BENchToP FLow cytometry

XN-SERIES AUTOMATED HEMATOLOGY SYSTEMS

BD FACSCanto II. A proven research platform for maximum reliability and the highest quality results

Flow Cytometry - The Essentials

FLOW CYTOMETRY. CyAn ADP. Analyzer

Introduction to. BD FACSAria TM Cell Sorter. Flow = Fluid Cyto = Cell Metry = Measurement

XN-9100 AUTOMATED HEMATOLOGY SYSTEMS

Each question may have MULTIPLE correct answers. Select all that are correct.

CyFlow Cube 8. High Performance Multilaser Flow Cytometry Analyser and Sorter

Attune TM Acoustic Focusing Cytometer Training. Manik Punj Attune Training

Your Research, Revolutionized

NovoCyte Flow Cytometer

Your Research, Revolutionized

MoFlo Astrios High-Speed Cell Sorter

Boundary-breaking acoustic focusing cytometry

cyflow space High-End Multilaser Desktop Flow Cytometry System with up to 16 Optical Parameters and 5 Light Sources

BD LSRFortessa. Performance without peer, choice without compromise

Evaluation of the CyFlow Cube 6 flow cytometer unit for the assessment of brewing yeast viability and vitality

Introduction to Flow Cytometry. -- BD FACSCanto II TM. Daisy Kuo Application Specialist BDBiosciences

Best practices in panel design to optimize the isolation of cells of interest

11/19/2013. Janine Zankl FACS Core Facility 13. November Cellular Parameters. Cellular Parameters. Monocytes. Granulocytes.

BD Accuri C6. Flow cytometry within reach.

ANAT 3231 Cell Biology Lab12 Stem Cell Analysis

Anatomy of a flow cytometer

Flow cytometry within reach.

Cancer inflammation research applications and products

Flexible, Intuitive and Affordable

Flow Cytometry For New PhDs

Novel Developments in Cytometry. Martin Adelmann Marketing Manager Cellular Analysis & Life Science Beckman Coulter EMEAI

INTRODUCTION TO FLOW CYTOMETRY

BD LSR Cell Analyzer. Performance without peer, choice without compromise

Flowcytometry Dirk Pacholsky

Review of techniques in imaging and cytometry. Peter Meeus Onze Lieve Vrouw Ziekenhuis, Aalst 7 may 2009, SCK/CEN Mol

High-throughput automation with the Attune NxT Autosampler: consistent results across all wells and across plates

Expanding Multicolor Options in Flow Cytometry with Novel Brilliant Violet TM Fluorophores. Carsten Wiethe Scientific Application Manager BioLegend

Theory and Applications for Cell Sorter

BASICS OF FLOW CYTOMETRY

The Basics of Flow Cytometry

Attune NxT Acoustic Focusing Cytometer The next generation in acoustic cytometry

Spherotech, Inc. 1. SPHERO TM Technical Note STN-8 Rev C

Principles of Multicolor Panel Design BD. BD, the BD Logo and all other trademarks are property of Becton, Dickinson and Company.

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE FLOW CYTOMETRY

Selecting Reagents for Multicolor Flow Cytometry

NovoCyte Quanteon F. Flow Cytometer. When Exceptional Performance Meets Simplicity

Basic Principles in Flow Cytometry. Flow Cytometry

Definitions. What functions does a flow cytometer be able to do? The build of the Flow cytometry and sorting. Flow cytometry

BD FACSCalibur. The flow cytometer for your routine cell analysis needs

Incorporating New, Bright Fluorochromes into Multicolor Panel Design

Using Fluorescence Spillover to Advantage

For outstanding performance in real-time PCR

Cell analysis and bioimaging technology illustrated

Innovations To Meet Your Needs

CS Automated haemostasis testing. Medium workload high class.

Automated Hematology Analyzer. Small Footprint. Big Difference.

The Worlds First Smart Flow Cytometer

seminar

What you need to know before designing a panel

Welcome to the CORES Flow Cytometry Sorter Facility

Navios EX FLOW CYTOMETER POWERFUL, DEPENDABLE CLINICAL FLOW CYTOMETRY

Designing and Implementing a High-Level Multicolor Flow Cytometry Assay. Brent Wood MD PhD Department of Laboratory Medicine University of Washington

CRC Flow Cytometry Core Facility Knut och Alice Wallenbergs Stiftelse

Cellometer Vision CBA

Everything counts. But nothing counts like the

Cyto-Mine. The Single Cell Analysis and Monoclonality Assurance System

The Cell Cycle, DNA Replication, and Mitosis

ALL INFECTOLOGY. and now. Gucker, 1947 Wallace Coulter Coulter Orifice, Kamentsky, 1965 Mack Fulwyler sorter BLOOD:

Live and Dead Cell Assay

NEWTON 7.0 BIOLUMINESCENCE & FLUORESCENCE IMAGING IN VIVO - IN VITRO IMAGING

ALL INFECTOLOGY COMMERCIALLY AVAILABLE DEVICES. and now BLOOD:

Review of techniques in flow cytometry. Peter Meeus Onze-Lieve-Vrouwziekenhuis, Aalst 5 may 2011, SCK/CEN Mol

AMREP FLOW CYTOMETRY CORE FACILITY. Flow Cytometry Data Analysis Workshop Friday 24 th October

Principles of Immunophenotyping

A legacy of innovation and discovery

Automated Hematology Analyzer. Differentiate with the XT-4000i

Flow Cytometry. Flow Cytometry Basics Guide

Selected Topics in Electrical Engineering: Flow Cytometry Data Analysis

Beyond Colorful Science. A Practical Approach to Setting Up Multicolor Panels

Sapphire. Biomolecular Imager THE NEXT GENERATION OF LASER-BASED IMAGING

determine optimum instrument settings for their own instruments and establish their own daily values.

BD Influx. A high-speed cell sorter that adapts to your way of thinking

GUAVA EASYCYTE SYSTEMS

BR-9516B. SNP genotyping analysis for medium to ultra-high throughput. GENOMELAB TM SNPSTREAM GENOTYPING SERIES

More on fluorescence

MF-ChemiBIS. Today s most comprehensive solution for your bio-imaging needs and applications. Documenting Nature

Application Information Bulletin: DuraClone IM Tubes Compensation setup for high content DuraClone reagents

Transcription:

CyFlow Space Your Flexible Flow Cytometer www.sysmex-partec.com

Ultimate Flexibility Modular System The CyFlow Space flow cytometer is a modular system with ultimate flexibility: from a basic configuration up to a multi-laser and multi-parameter system, you re sure to have access to the right tools. Forget about the limitations of fixed instrument configurations and restricted laser wavelengths. The CyFlow Space lets you adapt your flow cytometer to your individual application and can accommodate complex customized panels and experiments. With 10+ different laser choices, up to 16 parameters and a large range of optical filters from which to choose, you can optimize every fluorescence channel to meet your needs. Upgrades or changes are quick, easy and can be performed on site. Application Areas Research field Biomedical research Microbiology Cell biology Biotechnology Agroscience Marine biology Environmental science Industrial field Quality control Industrial biotechnology Industrial microbiology Food & beverage industry Plant & animal breeding Aqua culture Industrial development Report of a multi-color analysis of CD3/CD4/CD45 on CyFlow Space with FloMax software.

CyFlow Space Flow Cytometer Flexibility for Your Changing Needs Analyzing cells and particles, whether from blood, plasma, tissue, plants, cell cultures or other materials, is an important part of research and industrial development. To obtain statistically significant results and the confidence to proceed and invest further in your project, you need high throughput and a precise system for the detection of each cell type. The ability to measure thousands of cells within seconds is essential. Flow Cytometry (FCM) is the answer. Since it is a non-destructive method, it reflects the real distribution on a cellular level, quickly and with the utmost accuracy. Of course, FCM is not new as it has been a proven technology for over 45 years. With many available options, choosing the analyzer that meets both your immediate and future needs is critical. The CyFlow Space Affords You Space to Grow and Adapt The CyFlow Space flow cytometry system is unique in its offering of flexibility and precision. Thanks to its adaptable configuration, it allows you to grow with your ever-changing needs. Should those needs change, you can extend it or upgrade it, modularly. This kind of flexibility delivers the freedom to operate the instrument in routine settings, in specialized research departments or in core facilities with a range of connected working groups. In terms of FCM protocols, new fluorochromes with different spectra are launched to the market regularly. To take advantage of these changes, the ability to work with optimized excitation lights through different color lasers and suitable optical filter sets is a necessity. This calls for instruments that can be customized with respect to their configuration, but at the same time, remain user-friendly with a straightforward workflow. You want to concentrate on your research and not a complicated tool. CyFlow Space with Autoloading Station for high-speed automated sampling.

Ease of Use The CyFlow Space operation is intuitive and gives users easy access to the instrument s full capabilities. CyFlow Space maximizes up-time with a 5-minute startup and easy automatic shutdown. To further its user-friendliness, the CyFlow Space s operating software, FloMax, is intuitive and efficient. It integrates instrument control, including convenient acquisition and analysis, with both online and offline data analysis and a compensation tool in a single software package. Many of its functions are just a click away, such as digital compensation of fluorescent cross talk. Pre-defined and freely adaptable instrument setting and panel modes facilitate switching between different applications. FloMax is designed for applications including immunology, cell biology, microbiology, and biotechnology. To ensure compatibility with many of the most common FCM analysis programs, it uses the Flow Cytometry Standard (FCS) data format and lets you generate individual data reports in flexible formats. The unique Sysmex counting principle of True Volumetric Absolute Counting (TVAC) eliminates the need for time consuming and costly counting beads. The integrated CCD camera allows you to monitor the signal directly on the display to instantly check the sample flow. Modular Extension Possibilities As part of the Sysmex FCM concept, the CyFlow Space can be expanded and upgraded modularly by adding an Autoloading Station and other units, such as a piezoelectric cell sorter device. Upgrade options include adding laser light sources, optical parameters and fluorescence channels. CyFlow Space Autoloading Station To achieve higher throughput, you can add the Autoloading Station, which enables automated and accurate uptake of samples with high-speed sample loading. The station performs a flexible sample-to-sample cleaning procedure and can read both 96- and 384-well plates. FL3 dead cells Saccharomyces cerevisiae SSC FL1 live cells FL1 stain Lactobacillus sp. FL3 mitochondrial activity Staphylococcus sp. FSC FSC FL1 stain Separation of differently sized organisms during a single measurement in a scatter plot: Staphylococcus sp. Lactobacillus sp. Saccharomyces cerevisiae. The subsequent analysis comprised mitochondrial activity measurement of Staphylococcus DNA staining of Lactobacillus, and viability measurement of Saccharomyces.

CyFlow Space Sorting Module The sorting module is one of our unique technical solutions. It works as a closed system and lets you sort cells and particles precisely and stably, without sacrificing purity. It combines a high-resolution flow chamber with a piezo element and electric activation. In contrast to standard droplet sorters, the process in Sysmex sorters is smooth and reduces mechanical stress essential for numerous applications with fragile cell types, such as neuronal stem cells. As a closed sorting solution, it also offers the advantages of closed system sorting of viable cells for subsequent cell culture and aerosol-free sorting to prevent biohazardous exposure. Other modules, such as light polarization component or an anaerobic cabinet, are available on request. A Long History of Quality and Accuracy Since 1968, when Partec launched the first commercially available flow cytometer, we have been tightly focused on developing our technology in line with market demands. Sysmex stands for high precision and quality. With decades of experience in the biotechnology market, our technology has been used with great success in various fields in industry, research and development. The high quality of our FCM instruments results in systems with exceptional stability and sensitivity. In the CyFlow Space system, a highly precise optical bench is combined with a powerful electronic and computer system resulting in real-time signal analysis.

Technical Specifications Lasers / LEDs Detectors Exemplary dyes BLUE LASER 488 nm (50 mw fixed / adjustable to 200 mw) RED LASER 638 / 640 nm (25 / 40 mw) VIOLET LASER 405 nm (100 mw) UV LASER 375 nm (60 mw) HIGH-POWER UV LED 365 nm GREEN LASER 532 nm (30 / 100 mw) YELLOW LASER 561 nm (100 mw) ORANGE LASER 594 nm (50 mw) Green Red Red I Red II Far Red Red I Red II Far Red Blue Green Available light sources and exemplary detector configurations FITC / GFP / Alexa Fluor 488 PE / YFP PE-Texas Red / PI PE-Cy5 / PerCP PE-Cy5.5 / PerCP-Cy5.5 PE-Cy7 APC / APC-Cy5 APC-Cy5.5 / Cy5.5 APC-Cy7 Pacific Blue / Alexa Fluor 405 / CFP Cyan / AmCyan / brilliant violet 510 Pacific / brilliant violet 605 Blue DAPI / Hoechst 3342 Red Red Red Red Far Red mstrawberry / PE mcherry / PI / PE-Texas Red PE / DS Red / PE-Texas Red PE-Cy5 / PI / mcherry / mruby Texas Red / Alexa Fluor 594 / mstrawberry APC / mcherry / mrfp / JRed mplum Light Sources and Optics Flow System Electronics and Signal Processing FloMax Operating Software Computer System Options Weight Dimensions (W x H x D) Flexible choice of up to 5 light sources on the stand-alone analyzer and 3 light sources with the integrated sorter. Quartz flow cuvette for laminar sample transport and hydrodynamic focusing Biosafety cleaning system True Volumetric Absolute Counting (TVAC) based on mechanical volume measurement Selectable linear, 3- or 4-decade logarithmic scale 16-bit analog-to-digital converters, selectable trigger parameter Pulse height, area and width analysis for doublet discrimination Based on Microsoft Windows Master licence for instrument control, data acquisition and data analysis Data analysis software for multi-parametric flow cytometry data files in FCS 2.0 or FCS 3.0 standard format Latest industry standard Windows PC with Microsoft Office Microsoft Windows 7 professional 32-bit operating system 22" color LCD TFT display DVD-RW, USB and Ethernet ports Immersion gel coupling CyFlow Space sorter module CyFlow Space Autoloading Station with CyPad software approx. 37 kg main unit: 560 x 300 x 650 mm For Research Use Only. Not for use in diagnostic or therapeutic procedures. Manufacturer: Sysmex Partec GmbH Goerlitz, Germany Sysmex Corporation 1-5-1-Wakinohama-Kaigandori Chuo-ku, Kobe 651-0073, Japan Tel. +81 (78) 265-0521 www.sysmex.co.jp Sysmex America, Inc. 577 Aptakisic Road Lincolnshire, IL 60069, U.S.A. Tel. +1 (800) 379-7639 www.sysmex.com/us Sysmex Canada, Inc. 5700 Explorer Drive Suite 200, Mississauga, ON L4W0C6 Canada Tel. +1 (905) 366-7900 www.sysmex.ca Sysmex Latin America and the Caribbean Rua Joaquim Nabuco 615 - Bairro Cidade Jardim São José dos Pinhais Paraná Brasil CEP 83040-210 Tel. +55 (41) 2104-1314 www.sysmex.com/la 2016 Sysmex America Inc. All rights reserved. MKT-10-1234 Program availability varies by location. Programs and specification subject to change without notice. V02/15/16 P02/2016