SMALL GENERATION SYSTEM APPLICATION (10 kw OR LESS)

Similar documents
LEVEL 1 Application for Interconnection and Net Metering

Interconnection Application

NEW JERSEY BOARD OF PUBLIC UTILITIES N.J.A.C. 14:4-9 Net Metering and Interconnection Standards for Class I Renewable Energy Systems

Union Power Cooperative

LEVEL 2 Application For Interconnection And Net Metering

Delaware Electric Cooperative Generator Interconnection Application Long Form (For Use with Generators Greater than 100 kw)

Form B GENERATION INTERCONNECTION APPLICATION (Non-Inverter Based Generation and Inverter Based Generation > 25 kw)

LITTLETON ELECTRIC LIGHT DEPARTMENT 39 AYER ROAD LITTLETON, MA (M) (F)

SMALL GENERATOR INTERCONNECTION REQUEST (Application Form)

GRENLEC s Renewable Standard Offer

Part 1 Introduction and Overview

ATTACHMENT N. Small Generator. Interconnection Procedures and Agreement. (For Generating Facilities No Larger Than 20 MW)

atlantic cit~ elect,ic

REVISION NO.: 8 EFFECTIVE: 03/26/18

INTERCONNECTION APPLICATION AND AGREEMENT

CUSTOMER GUIDE FOR THE INTERCONNECTION DISTRIBUTED RESOURCES TO THE PUBLIC SERVICE COMPANY OF OKLAHOMA DISTRIBUTION SYSTEM

GARKANE ENERGY COOPERATIVE SMALL GENERATOR QUALIFIED FACILITY INTERCONNECTION APPLICATION

SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW)

CUSTOMER GUIDE FOR DISTRIBUTION SYSTEM INTERCONNECTION INVERTER-BASED DISTRIBUTED RESOURCES. < 50 kw

Inverter Energy System (IES) Network Agreement Form

Your guide to interconnecting to the We Energies distribution system

DISTRIBUTED GENERATION INTERCONNECTION PROCEDURES. June 21, 2011

DISTRIBUTED RENEWABLE ENERGY GENERATION POLICY

CUSTOMER GUIDE FOR THE INTERCONNECTION DISTRIBUTED RESOURCES TO THE AMERICAN ELECTRIC POWER DISTRIBUTION SYSTEM

CUSTOMER GUIDE FOR THE INTERCONNECTION DISTRIBUTED RESOURCES TO THE AMERICAN ELECTRIC POWER DISTRIBUTION SYSTEM

Dated: April 16, 2002

Distributed Generation. Technical Requirements and Interconnection Agreements

SMALL SCALE RENEWABLE ENERGY PROJECT STANDARD

INTERCONNECTION PROCEDURES FOR DISTRIBUTED GENERATION

Small Generator Interconnection Procedures (SGIP) (For Generating Facilities No Larger Than 20 MW)

effective date 1/8/01

ATTACHMENT P SMALL GENERATOR INTERCONNECTION PROCEDURES (SGIP) (For Generating Facilities No Larger Than 20 MW)

Distributed Renewable Energy Generation Interconnection Policy

City of Pasadena Water and Power Department Power Division DISTRIBUTED GENERATION FACILITIES INTERCONNECTION REQUIREMENTS REGULATION 23

Feed-in-Tariff (FIT) Connection Application Guidelines

ENERGEX Inverter Energy Systems

SERVICE CLASSIFICATION NO. 14-RA STANDBY SERVICE

NY State Unified Solar Permit

Bulletin Grounding and bonding of solar photovoltaic systems Rules , , , and

Address of Installation Building Permit #

Session of HOUSE BILL No By Committee on Energy, Utilities and Telecommunications 1-26

Addition to Section 4 - Special Use Regulations

ONCOR INTERCONNECTION APPLICATION AND PROCESS FOR DISTRIBUTED RESOURCES

APPLICATION FOR COMBINED HEAT AND POWER INCENTIVES

CONSOLIDATED EDISON COMPANY OF NEW YORK, INC. 4 IRVING PLACE NEW YORK, NY DISTRIBUTION ENGINEERING NETWORK SYSTEMS SECTION

BESCA CPS APPLICATION FOR REGISTRATION

Jammu and Kashmir State Electricity Regulatory Commission

APPLICATION FOR SOLAR PERMIT

DRAFT Commercial Solar Bylaw November 8, 2011

PERSONAL DATA Last Name: First: Middle: Today s Date: City: State: ZIP: Primary Telephone: Secondary Telephone: Address:

Small Generator Interconnection Procedures (SGIP) Customer Guide

Date: 12/19/2018 Docket #: 4881

MICRO-GENERATION NOTICE SUBMISSION GUIDELINE

Long Island Power Authority Seventh Revised Leaf No. 16

Chapter 5 Embedded Generation Information Pack

Date: March 23, 2015 Docket #: 4541

Generating Your Own Power On-Site Distributed g g Generation & the Interconnection Process

DISTRIBUTED ENERGY RESOURCE INTERCONNECTION PROCESS REQUIREMENTS

Sump Pump Upgrade and Down Spout Disconnect Subsidy Program

APPLICATION FOR EMPLOYMENT

Net Energy Metering 2.0 Solar PV Interconnection Handbook. Effective January 1, 2017

First Revised Sheet No. 449 Canceling Original WN U-60 Sheet No. 449 PUGET SOUND ENERGY Electric Tariff G SCHEDULE 449 RETAIL WHEELING SERVICE

RENEWABLE ENERGY ELECTRIC GENERATING SYSTEM APPLICATION INSTRUCTIONS

ROCHESTER PUBLIC UTILITIES

Metering Procedures for PA Renewable Energy Credits (MPREC)

THE POTOMAC EDISON COMPANY Electric P. S. C. Md. No. 53 Fifth Revision of Original Page No. 28 Canceling Fourth Revision of Original Page No.

Rule 21 Sheet 1 GENERATING FACILITY INTERCONNECTIONS

NY State Unified Solar Permit

DECLARATION OF AUTHORITY. This DECLARATION OF AUTHORITY ( Declaration ) is a declaration and certification made on by and between the following:

Texair Accuracy Ltd. TEXAIR - Paragliding Accuracy Competition AMD System Equipment Service Contract Agreement

Date: 2/28/2018 Docket #: 4772

CHOPTANK ELECTRIC COOPERATIVE, INC. P.S.C. Md. No. 3 Fifth Revised Page No. 59 COGENERATION AND SMALL POWER PRODUCTION RATE SCHEDULE X

CONTRACTOR S PERMIT APPLICATION for Residential PV Installation with e-inspection CA Health and Safety Code Section V p2s

Developer s Packet. Water Construction

BERRYESSA UNION SCHOOL DISTRICT PURCHASING DEPARTMENT 1376 PIEDMONT RD SAN JOSE, CA OFC FAX

2010 PAY FOR PERFORMANCE PROGRAM COMBINED HEAT & POWER APPLICATION PACKAGE

NY State Unified Solar Permit

NY State Unified Solar Permit

CHAPTER SMALL POWER PRODUCTION AND COGENERATION Definitions. As used throughout this chapter, except where otherwise indicated:

Developer s Packet. For Developments Requiring Large Meters

ROOFTOP PV GUIDELINES FOR SAFE AND LEGAL INSTALLATIONS IN CAPE TOWN

NY State Unified Solar Permit

2639 North Monroe Street, Suite B-112 Tallahassee, FL Application for Special Inspector Certification. Rule 61G Form FBPE/006 12/17

How to Connect Your Generation Facility ( 10 kw) To Kitchener-Wilmot Hydro s Distribution System

A. Section includes administrative and procedural requirements for substitutions.

FIELD TEST AND OPERATIONAL CHECK SECTION A. Refer to Section 16010, Electrical General Requirements.

NY State Unified Solar Permit

RATE 665 RENEWABLE FEED-IN TARIFF

Experimental Advanced Renewable Program (EARP) Anaerobic Digester. David Ronk

Net Energy Metering 2.0 Solar PV Interconnection Handbook. Effective December 1, 2017

Small Scale Solar Permit Application

Power Saver TM Program

CONTRACTOR PRE-QUALIFICATION DOCUMENTS. For Construction of the. Baxley WWTP Solar Array

NY State Unified Solar Permit

Date: 4/12/2018 Docket #: 4821

Business Practice Manual for Distributed Generation Deliverability. Version

SOLAR PV STC ASSIGNMENT FORM

NSTAR ELECTRIC COMPANY M.D.P.U. No. 6 WESTERN MASSACHUSETTS TERMS AND CONDITIONS GREEN OPTIONS SUPPLIERS

NY State Unified Solar Permit

Solar Photovoltaic System Permit

Transcription:

SMALL GENERATION SYSTEM APPLICATION (10 kw OR LESS) This application, terms, and conditions, and Interconnection Agreement is for Xcel Energy customers requesting the installation of a small generation system defined as 10 kilowatts or less. Xcel Energy recommends that the customer obtain all appropriate permits before purchasing equipment. Definitions QRU Qualified Regulated Utility REC Renewable Energy Credit Application Process The procedure for evaluating an Interconnection Request for a certified inverter-based Small Generating Facility no larger than 10 kw is shown below. The application process uses an all-inone document that includes a simplified Interconnection Request, simplified procedures, and a brief set of terms and conditions. (i) (ii) (iii) (iv) The Interconnection Customer ("Customer") makes an Interconnection Request ("Application") by filling out the Application Form and submitting it to the utility. The utility acknowledges to the Customer receipt of the Application within three (3) Business Days of receipt. The utility evaluates the Application for completeness and notifies the Customer within ten (10) Business Days of receipt that the Application is or is not complete and, if not, advises what information is missing. Within fifteen (15) days the utility shall conduct an initial review, which shall include the following screening criteria: (1) For interconnection of a proposed Small Generating Facility to a radial distribution circuit, the aggregated generation, including the proposed Small Generating Facility, on the circuit shall not exceed 15 % of the line section annual peak load as most recently measured at the substation or calculated for the line section. A line section is that portion of a utility s electric system connected to a customer bounded by automatic sectionalizing devices or the end of the distribution line. (2) If the proposed Small Generating Facility is to be interconnected on single-phase shared secondary, the aggregate generation capacity on the shared secondary, including the proposed Small Generating Facility, shall not exceed 20 kw. (3) If the proposed Small Generating Facility is single-phase and is to be interconnected on a center tap neutral of a 240 volt service, its addition shall not create an imbalance between the two sides of the 240 volt service of more than 20% of the nameplate rating of the service transformer. (4) No construction of facilities by the utility on its own system shall be required to accommodate the Small Generating Facility. Page 1 of 5 8/28/2006

(5) Provided all the criteria in Section 5.4 are met, unless the utility determines and demonstrates that the Small Generating Facility cannot be interconnected safely and reliably, the utility approves and executes the Application and returns it to the Customer. (6) After installation, the Customer returns the Certificate of Completion to the utility. Prior to parallel operation, the utility may inspect the Small Generating Facility for compliance with standards, which may include a witness test, and may schedule appropriate metering replacement, if necessary. (7) The utility notifies the Customer in writing or by fax or e-mail that interconnection of the Small Generating Facility is authorized within five Business Days. If the witness test is not satisfactory, the utility has the right to disconnect the Small Generating Facility. The Customer has no right to operate in parallel until a witness test has been performed, or previously waived on the Application. The utility is obligated to complete this witness test within ten (10) Business Days of the receipt of the Certificate of Completion. (8) Contact Information The Customer must provide the contact information for the legal applicant (i.e., the Interconnection Customer). If another entity is responsible for interfacing with the utility, that contact information must be provided on the Application. (9) Insurance - The Customer must provide proof of liability insurance for the installation. Page 2 of 5 8/28/2006

Application Form Application for Interconnecting a Certified Inverter-Based Small Generating Facility No Larger than 10kW This Application is considered complete when it provides all of the applicable and correct information required below. Additional information to evaluate the Application may be required by the utility. Application Fee A fee of $500.00 must accompany this Application for non pre-certified Interconnection Facilities. A fee of $100.00 is required for pre-certified Interconnection Facilities. Interconnection Customer Name: Contact Person: Address: Telephone (Day): (Evening): Fax: E-Mail Address: Engineering Firm (If Applicable): Contact Person: Address: Telephone: Fax: E-Mail Address: Page 3 of 5 8/28/2006

Contact (if different from Interconnection Customer) Name: Address: Telephone (Day): (Evening): Fax: E-Mail Address: Small Generating Facility Information Location (if different from above): Electric Service Company: Account Number: Small Generator 10 kw Inverter Process Inverter Manufacturer: Model: Nameplate Rating: (kw) (kva) (AC Volts) Single-Phase Three-Phase System Design Capacity: (kw) (kva) Prime Mover (Please circle one): Photovoltaic Reciprocating Engine Fuel Cell Turbine Other Energy Source (Please circle one): Solar Wind Hydro Diesel Natural Gas Fuel Oil Other (describe) Is the equipment UL1741 Listed? Yes No If Yes, attach manufacturer s cut-sheet showing UL1741 listing Estimated Installation Date: Estimated In-Service Date: Page 4 of 5 8/28/2006

The 10 kw Inverter Process is available only for inverter-based Small Generating Facilities no larger than 10 kw that meet the codes, standards, and certification requirements of Attachments 3 and 4 of the Small Generator Interconnection Procedures (SGIP), or the QRU has reviewed the design or tested the proposed Small Generating Facility and is satisfied that it is safe to operate. List components of the Small Generating Facility equipment package that are currently certified: Equipment Type Certifying Entity 1. 2. 3. 4. 5. Interconnection Customer Signature I hereby certify that, to the best of my knowledge, the information provided in this Application is true. I agree to abide by the Terms and Conditions for Interconnecting an Inverter-Based Small Generating Facility No Larger than 10kW and to return the Certificate of Completion when the Small Generating Facility has been installed. I further agree to relinquish my claims to any REC that will be generated with my equipment as part of this agreement. Signed: Title: Date: Contingent Approval to Interconnect the Small Generating Facility (For Company use only) Interconnection of the Small Generating Facility is approved contingent upon the Terms and Conditions for Interconnecting an Inverter-Based Small Generating Facility No Larger than 10kW and the return of the Certificate of Completion. Company Signature: Title: Date: Application ID number: Company waives inspection/witness test? Yes No Page 5 of 5 8/28/2006