USER MANUAL. MNPG50 Rev. 01 Edition 11/04/11. Model Infrared Lamp. Infrared WHF-312

Similar documents
USER MANUAL BR LED Headlight Rev /05/2016

ASAlaser, research and therapeutic solutions

Welding & Fabrication Tools Mini VaR Tool Kit

LIGHT FOR HEALTH LAZR 207/215

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

Whitening Lamp. Instructions for use. flaesh.com

INSTRUCTION MANUAL WARNING: BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!

HCP-7000 Opreator s Manual 1. Operator s Manual.

booster EX2 / EX3 Operating Manual Extrusion Welder Weldy AG Galileo-Strasse 10 CH-6056 Kaegiswil / Switzerland TECHSPANGROUP

Personal Massager PL021. Operating Manual

MLS the 3 rd Millennium Laser Therapy

Gelovit 200 en English

1. About this edition of the operating manual

USER S MANUAL release 1.0

Royal Sovereign RSL 2701 Laminator

BQ Revision : 1 ( )

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

LEISTER WELDMAX Mini-Hand Extruder

Applications of Modus ED-SWT

PMA 31-G. English. Printed: Doc-Nr: PUB / / 000 / 00

Effective and safe from the very first use PATHOLOGIES: TRIAX SYSTEM MRT SYSTEM INTERACTIVE PATHOLOGIES

6 Closet light. Model Due to continuing improvements, actual product may differ slightly from the product described herein.

User s Manual. Chart Projector GCP-7000

V-series 1. How to get started

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

400,000 FREE shots!!!

XSTi Standby UPS. 400VA, 600VA, 800VA Models. User & Installation Manual

The future is now power, speed, results

AL-SUS STEP LIFT USER GUIDE. AL-SUS Technologies Pte Ltd 1st August 2017

Thank you for purchasing our Infrared Body Slimming Blanket,please read the

DJ Switch 10F V2 ORDERCODE 50365

SPV-04 (POP MIRO 2TON) Reverse Osmosis Water Purifying System

USER S MANUAL release 2.0

400,000 FREE shots!!!

Minimally invasive laser therapy of uterine tumor

COPPER INSTALLATION GUIDE

C60 Standby UPS. 800VA Models. User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Bedhead Service Systems. Instructions for Use. July 2016 ASF-18 (0)

CCP-3100 Opreator s Manual 1. Operator s Manual.

OptoLum MegaLine RGBW Luminaire

Essential Requirements Straumann Custom-made Dental Restorative Devices According to 93/42/EEC annex I as amended by 2007/47/EC

USER S MANUAL release 2.0

EU MDR Timeline. Dr. Christian B. Fulda Jones Day FDLI Annual Conference Access materials at fdli.org/annual2018

Inverter Welder Model: RXT135E

Contents. 1. About this edition of user instructions

Warranty and Liability. QC Test. Trademarks

Variable Speed Controller

RENA XPS-3000 Base. User Guide. SC2000 Media Transport System

INSTRUCTIONS FOR USE FLOWMOULD

Owner s Manual.

Infrared Thermometer Stock No Part No.IT12:1B

Calibrate Accessory Actuators Instructions

AK 95 S Dialysis machine. Part of Gambro s complete HD system

Professional Weighing Equipment. K-Series Scales. Operation Manual KHR 6000 KHR 123 KHR 502 KHR 3001

Korea Medical Device Regulatory Requirements Update

J60 Lithium Ion UPS 350VA Model User & Installation Manual Xtreme Power Conversion Corporation. All rights reserved.

Heat press PF-150C. Spare parts manual and machine diagrams. Author: MA Pagina 1 di 17 Edition: 05/2011 Replaces:

ENel Sp. z o. o. - WROCŁAW DESIGN AND MANUFACTURE OF POWER ELECTRONIC DEVICES INVERTER WELDING MACHINE ENEL250A USER MANUAL DEALER:

3 PHASE ENERGY ELECTRONIC METERS MKB-363-M INSTRUCTION MANUAL ( M / 00 B

FILTRATION & UV SYSTEM

Operative Manual. Operative manual for diagnosis lamp GIMANORD

OPERATION MANUAL HARVEST OPAL

ZSH 2290 Pencil Hardness Tester. Instruction manual

Agenzia Italiana del Farmaco

Wealtec Corp. E-Centrifuge Microcentrifuge Operation Manual. Version 3.0 Item # *This instrument is intended for laboratory use only

1. About this edition of the operating manual

INSTALLATION OPERATION AND MAINTENANCE MANUAL GEARLESS MG250

Why choose OKI ISOLA?

Contents. 1. About this edition of user instructions

USER S MANUAL release 1.0

SHERMAN DIGITIG 200GD INSTRUCTIONS MANUAL

INSTRUCTION MANUAL Wardrobe lift 717

Instruction Manual Pocket scale

Saphyr System Safety Guide for Saphyr P/N 60325

Pallet Safe: Installation Supplement Rev

Advantages of magnetic die clamping for stamping presses

Installation and Adjustment Manual

Product environmental attributes THE ECO DECLARATION

Operator s Manual. Rev C 1/24/ O Neil Rd, Macedon NY Telephone: (315) Fax: (315)

Introduction Specifications Control Panel / Remote Unit Diagrams Setting Up the Unit Maintaining the Unit Safety info / Warnings Warranty Information

FAST SPOTTER WT-FS-5.0

ZX70 & ZX80 SERIES PRECISION DECADE RESISTANCE BOX

Agilent 16047D Test Fixture

The ideal service instrument for HVAC systems

Support for the National Accreditation Centre MOLDAC to successfully undergo the EA peer evaluation process. Twinning Project MD14/ENPI/TR/20

OPERATOR S INSTRUCTIONS

IVDR Breakout. Copyright 2017 BSI. All rights reserved.

CISA Reprocessing Systems

Reproduction or publication of the content in any manner, without express permission of the publisher, is prohibited.

The challenges of software medical device regulation.

Moving money forward UV MG

WARNING! Read all the information contained in this Manual, before you begin using the Equipment.

COMBIMASS. Technical Data COMBIMASS GA-m / GA-e Version

7700 TEST KIT OPERATIONS MANUAL

EasyArc ARC 200/ ZX7-300/ ZX7-400 INVERTER MMA WELDING MACHINE OPERATION MANUAL. Hong Kong Easyweld Limited

POWER PINNER BENCH HAND WELDER 7250 OPERATOR S MANUAL

SYMBOL GLOSSARY Explanation of symbols used in Quidel device labeling. Symbol Symbol Title Explanatory Text Standard Reference

SYMBOL GLOSSARY Explanation of symbols used in Quidel device labeling. Symbol Symbol Title Explanatory Text Standard Reference

Fast. Easy to use. Secure traceability.

BSI Audits for MDR Certification

Transcription:

USER MANUAL MNPG50 Rev. 01 Edition 11/04/11 Model Infrared Lamp Infrared WHF-312

I.A.C.E.R. Srl Via S. Pertini 24/A 30030 Martellago (VE) ITALY Tel. 041.5401356 Fax 041.5402684 e-mail: iacer@iacer.it http://www.iacer.ve.it IACER SRL Pagina 2 di 12 MNPG50-01 11/04/11

Summary Summary 3 Infrared therapy 4 Specifications 5 Technical Specifications 5 Purpose 5 Labelling 6 Machine body and assemblage 7 Instructions 8 Troubleshooting 9 Warnings 9 Maintenance, carriage and storage 10 Repairing 11 Spare parts. 11 IACER SRL Pagina 3 di 12 MNPG50-01 11/04/11

Infrared therapy The main effect of infrared is the thermal effect on the treatment zone: the heat increases body temperature and this causes the metabolism tissues increase, capillary vasodilatation and muscular relaxation. Infrared therapy is especially suitable for beauty treatments, tissues relaxation and renewal. The diffused heat results as a delightful effect for patient that needs this kind of therapy. Infrared antalgic effect is due to algogenic substances removal from pathological tissues and to contracted muscles relaxation. Infrared therapy is used to cure muscular contractures, cervical and lumbar osteoarthritis and bed sores. Moreover infrared rays are very efficacious as training before kinesitherapy. Bloodstream increase, after vasodilatation, moves in tissues a great quantity of nutritive substances, oxygen, white cells and antibody and makes easier catabolic removal. These biological modifications improve tissues trophism and help tissue damages compensation. Infrared WHF-312 is a medical device used to cure articular pains, both acute and chronic, thanks to his thermal effect that stimulates blood flow and tissues oxygenation. With infrared WHF-312 you can also set the radiation intensity in order to control light transmission. Moreover you can adjust therapy time from 10 to 60 minutes or in continuous, according to patient s requirements and specific pathology. 250 Watt maximum output power allows a correct irradiating power, thanks to Philips hot light bulb technology. IACER SRL Pagina 4 di 12 MNPG50-01 11/04/11

Specifications WHF-312 has the following specifications: Class IIa equipment (Directive 93/42/EEC, annexed IX, rule 9); Class II, applied part type BF (Classif. CEI EN 60601-1); Certificated CE1023; Equipment not protected against liquids penetration; Equipment and accessories not subjected to sterilization; Use of equipment is prohibited closet o flammable substances or in environments with high concentrations of oxygen; Continuous operating mode equipment; Equipment not suited to be used in external. Technical Specifications Power supply 220-240 VAC, 50-60 Hz Timer Impostabile 0 60 min. o continuo Max output power 250 W Dimensions 1600x500mm Max consumption 250 W Weight 5 Kg Purpose Clinical purpose: Use: Therapeutic Clinical and domestic use Articular pains, rheumatisms, tissues reconstruction, dermatitis, dermatosis treatment. Antalgic effect is used to cure muscular contracture, osteoarthritis, arthritis and as training before kinesitherapy. IACER SRL Pagina 5 di 12 MNPG50-01 11/04/11

Labelling 1023 MODEL NAME Infrared Pain Mitigate Treatment System WHF-312 RATED SUPPLY VOLT 220-240V~ SUPPLY FREQUENCY 50/60 Hz POWER CONSUMPTION 250W SERIAL NUMBER MFG. DATE In order to use the device for a long time, please read this user s instruction manual carefully before using it. Wonjin Mulsan Co., Ltd. Tel. 82-32-816-0552 Fax. 82-32-816-0557 Namdong Industrial Complex 10B-7L 623-6 Namchon-dong, Namdong-gu, Incheon, Korea MDD 93/42/EEC Compliance IACER SRL Pagina 6 di 12 MNPG50-01 11/04/11

Machine body and assemblage Head unit Top pipe Fixation handle Control box Lower part pipe Holder Connect the two fixation handle parties ( lower and top pipe) Connect head unit (infrared lamp) to fixation handle Connect cable to domestic plug (230 V). IACER SRL Pagina 7 di 12 MNPG50-01 11/04/11

Instructions Attention: standoff around 20-30 cm from treatment zone. On/Off button Intensity Timer How to use 1 Connect cable to domestic plug 2 Press ON button 3 Set timer, 0-60 minutes or continuous 4 Move head unit at a distance of 20-30 cm from treatment zone IACER SRL Pagina 8 di 12 MNPG50-01 11/04/11

5 Adjust intensity with the appropriate button Disconnect cable from domestic plug when not in use. Troubleshooting Problem WHF-312 cannot be turned on WHF-312 doesn t give out heat Solution Check connection to domestic plug Check ON/OFF button Check good condition of supply cable Check bulb condition Check bulb has been inserted correctly ATTENTION: in case of damage do not open or repair WHF-312 but contact the manufacturer and/or producer. Warnings Following warnings assure users security and they are given in order to avoid damages and/or lesions. Please read carefully user manual before use WHF-312. Do not position the lamp so that infrared ray hits a bleeding zone; Avoid infrared ray hits zones sensitive to burn; Keep distance from children; The device must be used with dry hand; Check correct voltage of domestic plug; Avoid direct beam to eyes; Avoid water direct contact; Avoid device fall; Standoff around 20-30 cm from treatment zone; Do not make treatment during sleep; IACER SRL Pagina 9 di 12 MNPG50-01 11/04/11

In case of damage do not repair the device but contact the manufacturer and/or producer; Do not touch the lamp (bulb) during the treatment: burn danger; Consult a doctor before starting treatment; If esogen thermotherapy causes pains, please suspend the treatment and consult a doctor. Maintenance, carriage and storage INFRARED WHF-312 doesn t need any particular maintenance if it is used according to user manual guides. Carriage precautions INFRARED WHF-312 doesn t need any particular carriage precautions: however we recommend to put away WHF-312 and its accessories after every treatment. Storage precautions The device is protected till following environmental conditions: temperature from +10 to + 40 C relative humidity from 30 to 85% pressure from 500 to 1060 hpa IACER SRL Pagina 10 di 12 MNPG50-01 11/04/11

Repairing Every intervention on device must be performed by manufacturer or authorized personnel. For any information contact: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a 30030 Martellago (VE) -ITALY Tel. 041.5401356 Fax 041.5402684 Further technical documentation can be provided by manufacturer, prior company authorization. Spar e parts. Contact the National Distributor or manufacturer for original spare parts: I.A.C.E.R. S.r.l. Via S. Pertini, 24/a 30030 Martellago (VE) Tel. 041.5401356 Fax 041.5402684 To preserve product warranty, functionality and product safety we recommend to use only original spare parts.. WHF-312 is manufactured by: WONJIN MULSAN CO., LTD. Namdong Industrial Complex 10B-7L 623-6 Namchon-dong, Namdong-gu, Incheon, Korea. Tel : +82-32-816-0552 Fax: +82-32-816-0557 www.wonjininc.net IACER Srl is the mandatary nominated by the manufacturer in the European Community with regard to WHF-312. WHF-312 is an exclusive distribution of IACER SRL. WHF-312. All rights reserved. Logo is owned by I.A.C.E.R Srl and is registered. IACER SRL Pagina 11 di 12 MNPG50-01 11/04/11