Application Note. Author. Abstract. Biopharmaceuticals. Verified for Agilent 1260 Infinity II LC Bio-inert System. Sonja Schneider

Similar documents
Reducing Cycle Time for Charge Variant Analysis of Monoclonal Antibodies

Protein Separation with ph Gradients Using Composite Buffer Systems Calculated by the Agilent Buffer Advisor Software

Charge Heterogeneity Analysis of Rituximab Innovator and Biosimilar mabs

Seamless Method Transfer from an Agilent 1260 Infinity Bio-inert LC to an Agilent 1260 Infinity II Bio-inert LC

Clone Selection Using the Agilent 1290 Infinity Online 2D-LC/MS Solution

Fraction Analysis of Cysteine Linked Antibody-Drug Conjugates Using Hydrophobic Interaction. chromatography. Agilent 1260 Infinity II Bio-Inert System

High-resolution Analysis of Charge Heterogeneity in Monoclonal Antibodies Using ph-gradient Cation Exchange Chromatography

Application Note. Authors. Abstract. Biopharmaceuticals

Molecular Characterization of Biotherapeutics The Agilent 1260 Infi nity Multi-Detector Bio-SEC Solution with Advanced Light Scattering Detection

Separate and Quantify Rituximab Aggregates and Fragments with High-Resolution SEC

Technical Overview. Authors. Abstract. Verified for Agilent 1260 Infinity II LC Bio-inert System

Disulfide Linkage Analysis of IgG1 using an Agilent 1260 Infinity Bio inert LC System with an Agilent ZORBAX RRHD Diphenyl sub 2 µm Column

mab Titer Analysis with the Agilent Bio-Monolith Protein A Column

Method Transfer from an Agilent 1200 Series LC to an Agilent 1260 Infinity II LC

Characterization of mab aggregation using a Cary 60 UV-Vis Spectrophotometer and the Agilent 1260 Infinity LC system

Automated Scouting of Stationary and Mobile Phases Using the Agilent 1290 Infinity II Method Development Solution

A Comprehensive Workflow to Optimize and Execute Protein Aggregate Studies

High-Throughput LC/MS Purification of Pharmaceutical Impurities

Application Note. Author. Abstract. Biotherapeutics and Biologics. Sonja Schneider Agilent Technologies, Inc. Waldbronn, Germany

Emulation of the Agilent 1100 Series LC Through Waters Empower Software Analysis of an Analgesic Mixture

High-throughput and Sensitive Size Exclusion Chromatography (SEC) of Biologics Using Agilent AdvanceBio SEC Columns

The Agilent 1260 Infinity BioInert Quaternary Pump. Scope of a low-pressure mixing UHPLC pump with Bio-Inert Capabilities

Agilent 1290 Infinity Binary LC System with ISET Emulation of a Waters Alliance 2695 LC Applying Concave, Convex, and Linear Gradients

Method Transfer from an Agilent 1260 Infinity LC to an Agilent 1260 Infinity II LC

Characterize mab Charge Variants by Cation-Exchange Chromatography

Developing Purification Strategies for the Agilent 1260 Infinity II Preparative LC/MSD System

Agilent AdvanceBio SEC Columns for Aggregate Analysis: Instrument Compatibility

Comparing gradient transfer of isocratic hold and delay volume addition using the Agilent 1290 Infinity LC with ISET

Mobile Phase Optimization in SEC Method Development

Application Note. Author. Abstract. Small Molecule Pharmaceuticals. Sonja Krieger Agilent Technologies, Inc. Waldbronn, Germany

Size Exclusion Chromatography of Biosimilar and Innovator Insulin Using the Agilent AdvanceBio SEC column

Improved Sensitivity with the Agilent 1290 Infinity Evaporative Light Scattering Detector (ELSD)

Agilent 1290 Infinity II 2D-LC Solution Biopharmaceutical Polymer Analysis. WCBP Jan 2017 Washington, DC

Cell Clone Selection Using the Agilent Bio-Monolith Protein A Column and LC/MS

AdvanceBio HIC: a Hydrophobic HPLC Column for Monoclonal Antibody (mab) Variant Analysis

Technical Overview. Author. Abstract. Edgar Naegele Agilent Technologies, Inc. Waldbronn, Germany

Application of Agilent AdvanceBio Desalting-RP Cartridges for LC/MS Analysis of mabs A One- and Two-dimensional LC/MS Study

Scale-up with the Agilent SD-1 Purification System analytical and preparative runs on a single system

Performance characteristics of the 1260 Infinity Quaternary LC system

Characterize Fab and Fc Fragments by Cation-Exchange Chromatography

Peptide Mapping: A Quality by Design (QbD) Approach

Application Note. Author. Abstract. Small Molecule Pharmaceuticals & Generics. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Benefits of 2D-LC/MS/MS in Pharmaceutical Bioanalytics

Analysis of Intact and C-terminal Digested IgG1 on an Agilent Bio MAb 5 µm Column

Application Note. Author. Abstract. Pharmaceuticals. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Agilent 1290 Infinity Binary LC System with ISET - Emulation of the Waters Alliance 2695 LC system analyzing b-blockers

Application Note. Author. Abstract. Pharmaceuticals. Detlef Wilhelm ANATOX GmbH & Co. KG. Fuerstenwalde, Germany mau

Faster Separations Using Agilent Weak Cation Exchange Columns

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

Application Note. Environmental. Agilent 1290 Infinity Binary LC. with ISET and fine-tuning. Agilent 1290 Infinity Binary LC.

Agilent 1260 Infinity Bio-inert Quaternary LC System. Infinitely better for bio-molecule analysis

Agilent 1290 Infinity Quaternary LC Support of Columns with 2.1 to 4.6 mm ID to 1200 bar

Performance Characteristics of the Agilent 1220 Infinity Gradient LC system

Rapid UHPLC Analysis of Reduced Monoclonal Antibodies using an Agilent ZORBAX Rapid Resolution High Definition (RRHD) 300SB-C8 Column

Bio-Monolith Protein G Column - More Options for mab Titer Determination

Determination of Asarinin in Xixin (Asari Radix Et Rhizoma)

TSK-GEL BioAssist Series Ion Exchange Columns

Cell Culture Optimization Using an Agilent Bio-Monolith Protein A Column and LC/MS

Separation of Recombinant Human Erythropoietin (repo) Using Agilent Bio SEC-3

Multiple Detector Approaches to Protein Aggregation by SEC

Minimizing Sample Carryover Using the Multiwash Function of the Agilent 1290 Infinity II Multisampler

Application Note. Biopharma. Authors. Abstract. James Martosella, Phu Duong Agilent Technologies, Inc Centreville Rd Wilmington, DE 19808

Fast Method Development Using the Agilent 1290 Infinity Quaternary LC System with Column Selection Valve

Optimizing Protein Separations with Agilent Weak Cation-Exchange Columns

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

Application Note. Rapid optimisation and development of an automated two-step purification procedure for monoclonal IgG antibodies.

Technical Overview. Author. Abstract. A.G.Huesgen Agilent Technologies, Inc. Waldbronn, Germany

A universal chromatography method for aggregate analysis of monoclonal antibodies

Developing Robust and Efficient IEX Methods for Charge Variant Analysis of Biotherapeutics Using ACQUITY UPLC H-Class System and Auto Blend Plus

Lifetime stability of size exclusion chromatography columns for protein aggregate analysis

Size Exclusion BioHPLC Columns

Separation of Monoclonal Antibodies Using TSKgel HPLC Columns

Controlling Agilent 1200 Series Rapid Resolution LC systems through Waters Empower chromatography data software. Technical Overview.

NISTmAb characterization with a high-performance RP chromatography column

Polishing of monoclonal antibodies using Capto S ImpAct

High-Resolution Charge Variant Analysis for Top-Selling Monoclonal Antibody Therapeutics Using a Linear ph Gradient Separation Platform

Fast and High Resolution Analysis of Intact and Reduced Therapeutic Monoclonal Antibodies (mabs)

Reversed-phase Separation of Intact Monoclonal Antibodies Using Agilent ZORBAX Rapid Resolution High Definition 300SB-C8 1.

CX-1 ph Gradient Buffer

Analysis of biomolecules by SEC and Ion-Exchange UPLC

Columns for Biomolecules BioLC Column Lines

Tools and solutions for separation of charged mab variants

Chromatography column for therapeutic protein analysis

HIC as a Complementary, Confirmatory Tool to SEC for the Analysis of mab Aggregates

IgG Purity/Heterogeneity and SDS-MW Assays with High- Speed Separation Method and High Throughput Tray Setup

High-Resolution Separation of Intact Monoclonal Antibody Isoforms

Separation of Native Monoclonal Antibodies and Identification of Charge Variants:

Analytical Instrument Qualification According to USP <1058>: Requirements and Examples for the Agilent 1290 Infinity LC System

An effective platform for purification of IgM monoclonal antibodies using Hydroxyapatite

Superdex 200 Increase columns

2 Liquid chromatography of biomolecules

Superdex 200 Increase columns

Automated QbD-Based Method Development and Validation of Oxidative Degraded Atorvastatin

Protein A Mag Sepharose Xtra Protein G Mag Sepharose Xtra

Agilent 1260 Infinity Bio-inert Quaternary LC

ISET. Agilent 1290 Infinity Binary LC with ISET, emulation of the Waters Alliance 2695 LC system analyzing aromatic acids. Application Note.

Convenient Purification of Monoclonal Antibodies using HiTrap rprotein A FF

Mass Spectrometry Analysis of Liquid Chromatography Fractions using Ettan LC MS System

Monoclonal Antibody Analysis on a Reversed-Phase C4 Polymer Monolith Column

Analysis of amoxicillin and five impurities on the Agilent 1220 Infinity LC System

Transcription:

Combining small-scale purification and analysis of monoclonal antibodies on one instrument Protein purification with high-volume injection using the Agilent 126 Infinity Bio-inert Quaternary LC System Application Note Biopharmaceuticals Author 2 2 1 Sonja Schneider 1 Agilent Technologies, Inc. Waldbronn, Germany 2 3 3 mab 1 2 2 1. 1. 2. 6 2 1 2 1 2 1 1. 1. 2. Abstract This Application Note presents an Application Solution for the small-scale purification of a monoclonal antibody from a cell lysate and the subsequent analysis on a single instrument, the Agilent 126 Infinity Bio-inert Quaternary LC System. Purification and polishing steps using preparative columns for Protein A purification and size exclusion chromatography were combined with high-volume injection using the Agilent 126 Infinity Bio-inert Manual Injector. Analysis of the purified mab was demonstrated using the Agilent Protein A Monolith for quantification and identification. In addition, charge variant analysis was carried out by a four-component ionic strength gradient using ion exchange chromatography, calculated with Agilent Buffer Advisor software. Verified for Agilent 126 Infinity II LC Bio-inert System

Introduction Preparative and analytical methods for protein purification and analysis require two different instrument setups. Protein preparation requires large injection volumes and high flow rates, whereas analytical methods require small injection volumes and lower flow rates. Traditionally, they are done on two instruments specifically designed for these purposes. With the 126 Infinity Bio-inert Quaternary LC, both tasks can be done on a single instrument. This Application Note shows a two-step purification procedure for monoclonal antibodies (mab) out of cell lysate using Protein A affinity chromatography followed by a size exclusion polishing step. Subsequently, the purified mab fraction was, on an analytical scale, identified and quantified with Protein A affinity chromatography and the charge variants were characterized with ion exchange chromatography (IEX). E.coli cell lysate was used as a surrogate model system for a hybridoma cell culture supernatant for the small-scale purification of a monoclonal antibody. Only in rare cases is a single step purification procedure sufficient to achieve the desired purity. In general, at least three purification steps are necessary for high protein purity: capture, intermediate, and polishing. Therefore, in this Application Note a two-step purification method was used, consisting of a capture and a polishing step. In the first step, the mab is captured by affinity chromatography using Protein A. Protein A is a surface protein originally isolated from the bacterium Staphylococcus aureus with a size of 6 kda. Protein A binds among other immunoglobulin (Ig) G variants with a high affinity to human IgG1 and is, therefore, the most common and accepted technique for antibody purification 1. The polishing step using size exclusion chromatography removes any remaining trace contaants, resulting from unspecific binding to column packing material, for example. For higher levels of purity, additional purification steps can be added prior to the SEC polishing such as IEX 2. Various chromatography techniques using different selectivities form powerful combinations for biomolecule purification. The monoclonal antibody used in this workflow was the anti-c-myc antibody, displayed in Figure 1 in an IEX ionic strength gradient resolving small acidic and basic charge variants. The analysis of the purified mab after the SEC polishing step is an essential part of the workflow to detere purity and quantity. Especially for pharmaceutically-used mabs, it is extremely important to thoroughly characterize the biomolecules to ensure efficacy and safety of the drug. One part of the characterization 2 2 1 1 Acidic variants Figure 1 IEX chromatogram of anti-c-myc monoclonal antibody. procedure, besides peptide mapping and aggregate analysis, is the deteration of charge variants of the mab, usually carried out by ion exchange chromatography. In this Application Note, the analysis of the purified mab includes, besides identification using Protein A chromatography, also quantification. The characterization of the mab in terms of charge variants was carried out using weak cation exchange chromatography in a -component ionic strength gradient calculated with Agilent Buffer Advisor software. To enable the combination of preparative and analytical techniques for biomolecules in one instrument, high volume injection is required for the preparative part. This can be achieved using the 126 Infinity Bio-inert Manual Injector and bio-inert PEEK loops, which are available up to 2 ml. This Application Note shows the purification of the monoclonal antibody anti-c-myc out of ml E.coli cell lysate with subsequent polishing and analysis on the 126 Infinity Bio-inert Quaternary LC. Main peak Basic variants 1 1 2 2 3 2

Experimental The Agilent 126 Infinity Bio-inert Quaternary LC System consisted of the following modules: Agilent 126 Infinity Bio-inert Quaternary Pump (G611A) Agilent 126 Infinity High performance Bio-inert Autosampler (G667A) Agilent 129 Infinity Thermostat (G133B) for sample cooling Agilent 129 Infinity Thermostat (G133B) for fraction cooling Agilent 129 Infinity Thermostatted Column Compartment (G1316C) with bio-inert solvent heat exchanger Agilent 126 Infinity Diode-Array Detector VL (G131D with bio-inert standard flow cell, 1 mm) Agilent 126 Infinity Bio-inert Analytical-scale Fraction Collector (G66A) Agilent 126 Infinity Bio-inert Manual Injector (G62A) Connecting capillaries:. mm (id) PEEK Columns HiTrap Protein A HP, 1 ml (GE Healthcare, Little Chalfont, United Kingdom) Superdex 2, 1/3 GL, 13 µm, 1 3 mm (GE Healthcare, Little Chalfont, United Kingdom) Agilent Protein A Monolith Agilent Bio MAb,.6 2 mm, µm, PEEK Software Agilent OpenLAB CDS ChemStation Edition for LC & LC MS Systems, Rev. C.1. [3] Agilent Buffer Advisor, Rev. A.1.1 Sample Agilent Anti-c-Myc Monoclonal Antibody, Clone 9E1 spiked into ml E.coli cell lysate Solvents and samples Protein A purification SEC polishing Protein A analysis Buffer A PBS PBS PBS H 2 O dd All solvents used were LC grade. Fresh ultrapure water was obtained from a Milli-Q Integral system equipped with a.22-μm membrane point-of-use cartridge (Millipak). PBS (phosphate buffered saline) was purchased from PAA (GE Healthcare, Little Chalfont, United Kingdom). MES (2-(N-morpholino) ethanesulfonic acid monohydrate) and MES-Na (2(N-morpholino)ethanesulfonic acid sodium salt) were purchased from Merck, Darmstadt, Germany. NaCl was purchased from VWR, Radnor, PA, USA. E.coli cells and the CelLytic B Plus Kit were purchased from Sigma- Aldrich, St. Louis, MO, USA. Amicon Ultra Centrifugal Filters 3K were purchased from Millipore, Billerica, MA, USA. IEX 2 mm MES (Buffer Advisor calculation) Buffer B Glycine-HCl, 1 mm, ph 3 Glycine-HCl 1 mm, ph 3 NaCl, 1 M Buffer C MES, 6 mm Buffer D MES-Na, 3 mm Table 1 Solvents. 3

Chromatographic conditions Protein A purification Preparative SEC polishing Flow rate:. ml/. ml/ Column: HiTrap Protein A HP, 1 ml (GE Healthcare) Superdex 2, 1/3 GL, 13 µm, 1 3 mm (GE Healthcare) Gradient: Injection volume:. utes 1% A. utes 1% A 1. utes 1% B 6. utes 1% B Stop time: 6 utes ml (manual injection using ml bio-inert PEEK sample loop) Temperature TCC: RT RT Thermostat fraction collector: 6 C 6 C DAD: Peak width: Fraction collection Peak detector mode: Fraction trigger mode: Fraction trigger timetable: 2 nm/ nm Ref.: OFF >. utes (1. second response time) ( Hz) Threshold only & 1 Peak-based with a maximum peak duration of 3 utes utes & off utes & on Isocratic - 1% A Stop time: utes µl (manual injection using µl bio-inert PEEK sample loop) 2 nm/ nm Ref.: OFF >. utes (1. second response time) ( Hz) Threshold only & 2 Peak-based with a maximum peak duration of 1 utes Due to the separation technique of the SEC polishing step, the fractionated samples were diluted to a large extent. Before analytical chromatography could be applied to the sample, a concentration step was carried out by ultrafiltration using Amicon Ultra Centrifugal Filters 3K. The IEX -component ionic strength gradient from to 2 mm NaCl in 2 utes was calculated with the Agilent Buffer Advisor software for 2 mm MES buffer concentration at ph 6.. The best ph value for separation was estimated by ph scouting using Buffer Advisor (data not shown). Analytical Flow rate: Protein A monolith.7 ml/ Column: Agilent Protein A monolith Bio MAb column,.6 2 mm, µm Gradient:. utes 1.% A 1. utes 1.% B 3. utes 1.% A Stop time: 3 utes Post time: utes Injection volume:.16 to µl 2 µl Temperature TCC: Thermostat Autosampler and Fraction collector: DAD: Peak width: RT 6 C 2 nm/ nm Ref.: OFF IEX >. utes (1. second response time) ( Hz). utes A: 1.% B:. % C: 11.9% D: 36.7% 2. utes A: 3.7% B: 2.% C: 11.1% D: 3.2% 3. utes A:.9% B:.% C: 11.3% D: 37.% 3. utes A:.9% B:.% C: 11.3% D: 37.% 36. utes A: 1.% B:.% C: 11.9% D: 36.7% Stop time: 36 utes Post time: 2 utes

Results and discussion A ml E.coli lysate solution was spiked with the monoclonal antibody anti-c-myc and injected into the 126 Infinity Bio-inert Quaternary LC System using the 126 Infinity Bio-inert Manual Injector with a -ml bio-inert PEEK loop. Using a preparative affinity column coated with Protein A, the mab could be purified out of the E.coli lysate, see Figure 2. The mab was captured and successfully separated from the constituent parts of the E.coli cell lysate with an enormous protein content of over 1 mg/ml. The system could be operated at extremely low backpressure due to the low backpressure of the preparative column, the manual injector and PEEK capillaries with. mm id. The system backpressure of the complete run was below bar with less than 1-bar backpressure over the column. The second step of the purification procedure using SEC revealed several nonspecifically bound proteins after the Protein A capture step, see Figure 3A. Again, the system could be operated at very low backpressure not exceeding 1 bar. Five peaks were fractionated and the fractions concentrated by ultrafiltration for further analysis with Protein A affinity chromatography and IEX. Figure 3B displays identification using Protein A affinity chromatography as the first part of the mab analysis. The first peak in the SEC chromatogram shows the presence of mab, because the corresponding Protein A analysis showed significant retention. Conversley, none of the other fractions showed representative retention, demonstrating that their content is not captured by Protein A. 3 3 2 2 1 1 P1-D-1 1 2 3 6 Figure 2 MAb purification using Protein A affinity chromatography. A B 2 2 1 1 mab 1 2 Polishing step using SEC 2 3 3 2 1. 1. 2. 6 2 1 2 Identification using Protein A Monolith 1 2 Figure 3 A) Polishing step using SEC and B) identification of the fractionated mab using Protein A affinity chromatography. 1 1. 1. 2.

Several pitfalls, regarding manual injection and fraction collection, can be easily avoided by considering following steps: Connect the pump to the fraction collector in the Configuration options under Linked pump. This important setting avoids overfilling of the fractionation vials or wells due to the correct communication of the flow rate. Start the run over Single sample to ensure that the fraction collection starts in the correct location as specified in the Sample info options. Insert a vial position into the Sample parameters within the Sample info option even though the manual injector is used. Otherwise, the system is going to perform a blank run. In addition to identification, the purified mab was quantified with Protein A affinity chromatography using a calibration curve, measured with pure antic-myc. The calibration curve showed a good correlation factor of.997 from 7 ng to 2 µg total protein on the column, see Figure. The quantification of the purified anti-c-myc resulted in a concentration of.9 mg/ml. Area 7 6 3 2 cmyc, DAD1 A Area = 39.39777*Amt - 1.7163 Rel. Res%(1):. 7 1 13 6 Correlation:.997 2 1 1 Amount (µg) Level 9 2 1 7 6 2. 1.3.62 3.313 2.16 1.7 Amount (µg) Figure Correlation curve of anti-c-myc with Protein A affinity chromatography. 9 6

As the final step, the purified mab was analyzed for charge variants using a -component ionic strength gradient at ph 6., calculated with Agilent Buffer Advisor software. The IEX chromatogram reveals some small acidic and basic charge variants of the anti-c-myc mab, see Figure. The chromatogram looks nearly identical compared to the pure anti-c-myc monoclonal antibody before it was spiked into the E.coli lysate (Figure 1). Hence, the purification was considered successful. Conclusion This Application Note shows the combination of small-scale protein preparation and subsequent analysis on a single instrument, the Agilent 126 Infinity Bio-inert Quaternary LC. A two-step purification procedure using preparative columns was applied to purify the monoclonal antibody anti-c-myc from E.coli cell lysate. The first step using Protein A affinity chromatography captured the anti c Myc and separated the mab from other constituent parts of the E.coli cell lysate. The SEC polishing step revealed several unspecific bound proteins after the Protein A affinity capture, which were fractionated and successfully separated from the mab as the target molecule. Both purification steps required high volume injection using the 126 Infinity Bio-inert Manual Injector. In addition, both purification steps could be operated at extremely low backpressure below 1 or even below bar total system backpressure. 3 3 2 2 1 1 Acidic variants 1 1 2 2 3 3 Figure Charge variant analysis of the purified anti-c-myc monoclonal antibody. After fractionation and concentration of the sample, the mab was analyzed regarding identity, quantity, and charge variants. A calibration curve of anti-c-myc over approximately four orders of magnitude revealed good correlation with a correlation factor of.997 for the quantification using the Protein A Monolith. In addition, charge variant analysis was carried out by a four-component ionic strength gradient, calculated with Buffer Advisor software. In summary, the Agilent 126 Infinity Bio-inert Quaternary LC enables small-scale preparative and analytical workflows on a single instrument. Main peak Basic variants References 1. D. Low et al. Future of antibody purification, Journal of Chromatography B : 63, 27. 2. Protein Purification Handbook, GE Healthcare. 7

www.agilent.com/chem/ bio inert For Research Use Only. Not for use in diagnostic procedures. Agilent Technologies, Inc., 212-217 Published in the USA, November 2, 217 991-119EN