Hazardous Waste Management at Remote (SQG) Sites

Similar documents
Annual Training for Hazardous Waste Generators

Safety Best Practices Manual

Hazardous Waste Removal and Disposal

RCRA HAZARDOUS WASTE PROGRAM

Table of Contents. Community College of Allegheny County Hazardous Waste Program. I. Introduction. Scope and Application. Program Description

MANAGING HAZARDOUS WASTE AT WSU TRI-CITIES

WARTBURG COLLEGE ENVIRONMENTAL AND OCCUPATIONAL SAFETY PROGRAM HAZARDOUS WASTE PLAN

WARTBURG COLLEGE ENVIRONMENTAL AND OCCUPATIONAL SAFETY PROGRAM HAZARDOUS WASTE PLAN

Overview of State and Federal Regulation of Hazardous Waste

Small Quantity Generator (SQG) of Hazardous Waste

APPENDIX H RULE 98 REQUIREMENTS CHART

HAZARDOUS AND SOLID WASTE ENVIRONMENTAL REQUIREMENTS CHECKLIST FOR CONSTRUCTION PROJECTS

New Jersey Institute of Technology (NJIT) Guidelines for the Management of Regulated Chemical Waste

Facilities Management

RCRA 101. Michael Gage

Environmental Health and Safety at Alfred University. Identifying A Hazardous Waste

RCRA TRAINING FOR HAZARDOUS WASTE GENERATORS

LARGE QUANTITY GENERATOR CHECKLIST

Hazardous Waste Handling Certification

LARGE QUANTITY GENERATOR (LQG) OF HAZARDOUS WASTE

For ethidium bromide waste that is generated at Harvard, each waste stream is to be managed or accumulated as described below.

WASTE MANAGEMENT PROGRAM

WORD GAME PARKED/PARKED

Hazardous Waste Generator Improvements Rule

Hazardous Waste Section. Universal Waste SQH Requirements

9/4/2013. Training for all employees on the Haz Com Program. Manufacturer Labels on every chemical container

SMALL QUANTITY GENERATOR CHECKLIST

The Future of Chemistry. Molecule 5110 Port Chicago Hwy Concord CA Phone: (510) /14/

DUKE Occupational and Environmental Safety Office

Essentially they are hazardous wastes with low hazards and high volumes in commerce and so are designated as a lower level of waste

Hazardous Waste Storage and Disposal Guide

2. Policy. The policies established in furtherance of the above purpose are as follows:

EDMONDS COMMUNITY COLLEGE WASHINGTON STATE COMMUNITY COLLEGE DISTRICT 23

COMPLIANCE ASSISTANCE VISIT REPORT

Hazardous Waste Section. Hazardous Waste Standards For CESQG and SQG

Managing Universal Waste 40 CFR 273 & 22 CCR 66273

UNIVERSITY OF SOUTHERN MAINE HAZARDOUS WASTE MANAGEMENT PLAN GORHAM CAMPUS

Hazardous waste. The words alone make you think of a material that needs to be handled with extra precaution. Hazardous wastes are process

Hazardous Waste Small Quantity Generator Checklist

York College. Regulated Wastes Awareness Training

YORK COLLEGE. Universal Wastes Awareness Training

UNIVERSITY OF SOUTHERN MAINE HAZARDOUS WASTE MANAGEMENT PLAN PORTLAND CAMPUS

2/19/2013. Determine which ones are hazardous waste. Keep records. 1. Identify all wastes generated. 2. Determine pounds of HW per month

Cornerstone of Hazardous Waste Management

Universal Pharmaceutical Waste

Regulated Waste Management Plan

COLLIN COLLEGE EPA COMPLIANCE TOOLKIT

Overview of the Resource Conservation and Recovery Act ( RCRA ) and Comprehensive Environmental Response, Compensation, and Liability Act ( CERCLA )

Environmental Management Chapter ALABAMA DEPARTMENT OF ENVIRONMENTAL MANAGEMENT LAND DIVISION - HAZARDOUS WASTE PROGRAM ADMINISTRATIVE CODE

HAZARDOUS WASTE MANAGEMENT

APVG-GP-T SUBJECT: Annex U (Environmental Compliance) to Pohakuloa Training Area (PTA) External Standing Operating Procedures (SOP).

Universal Waste Mercury Containing Equipment Management Practice

A Look Back at the First Year of No Stricter Than Implementation. Kathy S. Flippin Hazardous Waste Program

WASTE MANAGEMENT GUIDE. Creighton University Environmental Health and Safety

Universal Waste Management

Experimental investigation on different properties of hazardous incinerator bottom ash concrete V.Manjunatha, Dr V.Ramesh

Questions, do not hesitate to call my office at or

Rags and Absorbents Disposal

Waste Compliance Refresher

TENNESSEE DEPARTMENT OF TRANSPORTATION DISPOSAL CORE PLAN FOR THE MANAGEMENT OF HAZARDOUS WASTES, UNIVERSAL WASTES, AND USED OIL

Managing Hazardous Chemical Waste

Hazardous Material Control. Hazardous waste Chemical Hygiene Lab Safety std. Biological Pathogens

August 11, Hazardous Waste Management

Hazardous Waste: the usual suspects and how to manage them

Resource Conservation and Recovery Act (RCRA) Pharmacy Waste Management: An Emerging Issue

DISPOSAL OF HAZARDOUS WASTE, CHEMICAL WASTE AND UNUSED CHEMICALS

RCRA HAZARDOUS WASTE REGULATION SUMMARY: Large Quantity Generators (LQG) UNIVERSITY OF WISCONSIN SYSTEM

HAZARDOUS WASTE MANAGEMENT AT UM-FLINT

Hazardous Waste Generator Requirements

Table 1: Summary of Universal Waste (UW) Handler Requirements*

Hazardous Waste Section. Hazardous Waste Determinations

HAZARDOUS MATERIAL ASSESSMENT

Compliance Bulletin Hazardous Waste Management of Electronics Waste reviewed/revised June 2003

Transportation of Dangerous Goods

THE UNIVERSITY OF SOUTHERN MAINE. Universal Waste Program

Product Usage Compliance Parameters Operational Controls

TARLETON STATE UNIVERSITY HAZARDOUS WASTE MANAGEMENT PROGRAM

Environmental Management Procedure (EMP) Tab 1. Subject: Collection of Solid Waste and Recycling from Maintenance Operations

Outreach Train-The-Trainer Universal Waste & Used Electronics 2014

ENVIRONMENTAL HEALTH AND SAFETY STANDARD OPERATING PROCEDURES

Dangerous Goods (Storage and Handling) Regulations 2000 and Code of Practice

STANDARDS FOR UNIVERSAL WASTE MANAGEMENT...

Safety Data Sheet 1. CHEMICAL PRODUCT AND COMPANY IDENTIFICATION

Creighton University Comprehensive Universal Waste Program

2018 Hazardous Waste Compliance Calendar

Safety Regulations and Procedures ENVIRONMENTAL HEALTH Reuse, Recycling or Disposal of Hazardous Materials (HAZMAT) - S70.

Hazardous Waste Being Compliant and helping the Environment

Hazardous Waste Management Program

7:26-7.2, NJAC 40 CFR 40 CFR

Hazard Waste Management Training. This training is a one-time requirement for personnel generating waste at WCU

Environmental Guidelines

DRI Procedure for Moving/Transporting Chemicals 1

Saves your life Protects your health Preserves your equipment Makes your customers happy Minimises risks Protects the environment

IX. Hazardous Chemical Waste Management

Offsite Shipping (DOT)

ADEQ s Hazardous Waste Unit. Webinar: Hazardous Waste Determination and Generator Status February 14, 2017

Lesson Plan Template

Hazardous Waste Management. Office of Environmental Health and Safety

VOLUNTARY PURCHASING GROUPS, INC.

Universal Waste Management Plan

Transcription:

Department: The University of Maine System / Safety and Environmental Management Page 1 of 7 Hazardous Waste Management at Remote (SQG) Sites General In order to maintain a Small Quantity Generator (SQG) status as defined by the State of Maine Department of Environmental Protection (MDEP), remote sites must maintain their waste generation within certain regulated limits and meet all other regulatory requirements. The following guidance is established in accordance with the MDEP s Hazardous Waste Rules and other pertinent regulations applicable to the management and disposal of hazardous waste. In order to be considered a SQG of hazardous waste, a generator may not store more than 55 gallons of hazardous waste or 1 kg of acutely hazardous waste, total on the entire site, at any time. Less than 27 gallons or 100 kg of hazardous waste or 1 kg of acutely hazardous waste can be generated in any calendar month (other limits may also apply). Please Note: The state of Maine uses slightly different terminology for generator status from the federal Environmental Protection Agency (EPA). Maine s SQG rules are in compliance with the EPA s federal rules for Very Small Quantity Generators (VSQGs). What the EPA defines to be a SQG is termed as a SQG+ by the MDEP. There is no variation in the term used to describe a LGQ (Large Quantity Generator) by the EPA or MDEP. Regulatory Guidance The Emergency Planning and Community Right to Know Act Maine Department of Environmental Protection (DEP) Chapters 850-851 U.S. Environmental Protection Agency (EPA) Parts 260-263 Requirements Waste Determinations: All hazardous materials which are useless or unwanted must be considered hazardous wastes unless specifically determined to be non-hazardous. Waste determinations must be made by persons properly trained in hazardous waste regulations. Determinations are typically made using knowledge of the waste by a trained SQG Site Manager or by Safety and Environmental Management (SEM). When knowledge of the hazard characteristics is indeterminate or unknown, waste analysis is required. Once a waste determination is made, the waste is either managed as a hazardous waste or discarded, as appropriate. Containers, Compatibility, and Storage: All wastes must be placed in a Department of Transportation (DOT) approved shipping containers before shipment off site. Waste chemicals must be stored in containers that are chemically compatible with the contents. Plastic lined, 1-gallon amber bottles or a DOT rated drums are examples of acceptable containers. Milk jugs and plastic containers that held other commercial products are not appropriate containers. Incompatible wastes must not be mixed together.

Department: The University of Maine System / Safety and Environmental Management Page 2 of 7 Containers must be kept tightly closed when waste is not being added to or removed from the container. All wastes must be stored indoors on a firm, working surface and have secondary containment to prevent the release of hazardous waste to the environment. Accumulation Limits: The following limits may not be exceeded at any time on SQG sites. These limits include the total of all hazardous waste generated or stored anywhere on the entire site. Maximum Amount of Waste Stored in any calendar month: Standard Hazardous Wastes Acutely Toxic Wastes Empty P-listed Containers 55 Gal 1 Kg None over 20 liters Containers must be dated when full and removed within 180 days of the full date. The time required to fill a container does not matter. Central Accumulation Areas (where waste is accumulated and stored) must be inspected monthly and containers should be removed/replaced, as necessary, to prevent container deterioration or excess waste accumulation. Schedules for waste pickups are made by SEM through each Remote Site Manager and are done at least annually. Pickups may be more frequent, when necessary; to ensure that accumulation limits are not exceeded. Labeling Requirements: Each hazardous waste container must be properly labeled. Fill in all applicable information, being sure to include all hazardous chemical constituents and the approximate concentration of each. Sample Labels (Available from Site Safety Contact) Accumulation Start and Full dates are very important since they are used to determine the amount of waste generated in a calendar month for generator status calculations.

Department: The University of Maine System / Safety and Environmental Management Page 3 of 7 Disposal, Manifesting and Recordkeeping: Whenever a waste vendor is on site there must be at least one person (usually the Site Manager) who is trained in the Hazardous Waste Regulations and who has current DOT Waste Manifest Training. In accordance with University of Maine System requirements (Administrative Practice Letter Section IV-D, Record Retention Practices), Hazardous Waste Manifests and accompanying documentation should be retained indefinitely. MDEP requires that Manifests be available on-site for at least 3 years and requires that all waste determinations and waste analysis be available for at least 10 years. Emergency Response Equipment and Procedures: All personnel are required to be trained in emergency procedures during their Department Annual Safety Training. Area-specific Emergency Action Plans, the location and availability of Safety Data Sheets (SDSs), use and limits of Personal Protective Equipment, and department spill procedures are typically included as part of an employee s annual training. Emergency phone numbers, including the number of the local fire department and site manager or Emergency Coordinator, should be posted near each telephone. The locations of fire extinguishers, alarm pull stations (if any), and spill control equipment should be clearly marked. Each SQG site must designate at least one Facility Emergency Coordinator (FEC) capable of responding to emergencies within a short period. The FEC or their designee must call the fire department in the event of a fire, ensure that the flow of hazardous materials is contained in the event of a release (if trained and authorized), and ensure that any contaminated materials or soils are removed. FECs are not expected to clean up spills of hazardous materials or hazardous waste. Hazardous Waste Training (SQG Site Waste Handlers): MDEP regulations require that persons handling waste at SQG sites be trained to ensure that they are thoroughly familiar with proper handling and emergency response procedures relevant to their responsibilities, which may include any or all of the topics outlined in this policy: Hazardous Waste Determinations (Site Managers, at a minimum) Containers, Compatibility and Storage Accumulation Limits Labeling Requirements Disposal and Manifesting (Site Managers, at a minimum) and Spill response procedures (Emergency Action Plan) Training should be conducted at the time of initial assignment to duties. All training must be documented. Training must be updated as necessary to meet the requirements established by the Hazardous Waste Rules.

Department: The University of Maine System / Safety and Environmental Management Page 4 of 7 Responsibilities The Department of Safety and Environmental Management is responsible for the management of the University contract for disposal of hazardous wastes generated by all SQG sites. The Facility Emergency Coordinator (FEC) is responsible for responding to emergencies within a short period of time (1 hour or less), making the required notifications in the event of a fire or release of hazardous materials, contacting designated responders to clean-up emergency spills, and arranging for removal of contaminated materials or soils. SQG Site Managers are responsible for the management and disposal of wastes generated at their site, including regular assessment of waste storage, generator status and completion of the monthly inspection form (See Appendix B) Each employee that generates hazardous waste is responsible for attending the site-specific training and maintaining appropriate chemical and waste storage in accordance with these guidelines. Employees are also responsible for notifying the SQG Site Manager of wastes accumulated as soon as containers are full and of chemicals that are no longer needed. Definitions Acutely Hazardous Waste: Hazardous wastes that are listed by the EPA or DEP as Acutely Hazardous carrying a P waste code (P-listed waste) or any of the following F-listed wastes F020- F023, F024, and F026-F028 containing chlorobenzenes or chlorophenols. Corrosive: Aqueous solutions with a ph less than or equal to 2, or greater than or equal to 12.5; liquids that corrode steel or aluminum at a rate greater than 0.250" per year; and chemicals that cause visible destruction or irreversible alteration of human tissue. Hazardous Waste: Wastes that display the characteristics of ignitability, corrosivity, reactivity, or toxicity, or are listed as hazardous wastes by the EPA or DOT for displaying either one of the hazardous waste characteristics or for other reasons of potential harm to human health or the environment if improperly disposed. Ignitable: Liquids, other than aqueous solutions containing at least 24% alcohol by volume, with a flash point less than 60 C (140 F) or solids capable, under standard temperature and pressure, of causing fire through friction, absorption of moisture, or spontaneous chemical changes and which when ignited, burn so vigorously and persistently that they create a hazard. Listed Wastes: Chemicals specifically listed by name in EPA or DEP regulations including characteristic of toxicity as defined in 40 CFR 261.24; wastes from non-specific sources ( F list); wastes from specific sources ( K list); Commercial products, off-spec products, spill residues ( U list & P list): PCB-containing waste oils, transformers, and ballasts containing or possibly containing PCB oils ( M list).

Department: The University of Maine System / Safety and Environmental Management Page 5 of 7 Reactive: Substances which are normally unstable and readily undergo violent change; react violently with water; are capable of forming toxic vapors, gases, or fumes when mixed with water in a quantity sufficient to present a danger to human health or the environment; and are capable of detonation or explosive reaction. Universal Hazardous Waste includes waste Cathode Ray Tubes (CRT), mercury containing lamps and devices and non-leaking PCB Ballasts. At SQG sites all Universal Hazardous Wastes are labeled, stored and managed similar to other hazardous wastes, however their accumulations are counted separately from hazardous waste accumulations towards the generators status as a SQG. For Additional Information Contact your Site Safety Contact or Safety and Environmental Management at 207/581-4055. See Appendix A Hazardous Waste Management Remote Site Campus Contacts Document History Date originally published: 03/16/00

Department: The University of Maine System / Safety and Environmental Management Page 6 of 7 Appendix A Hazardous Waste Management Remote Site Campus Contacts Insert form Hazardous Waste Management Remote Site Campus Contacts (0811061.1) here.

Department: The University of Maine System / Safety and Environmental Management Page 7 of 7 Appendix B SQG Central Accumulation Area Monthly Checklist Insert form SQG Central Accumulation Area Monthly Checklist (0811061.2) here.