Lightning Protection System for PC Buildings

Similar documents
SECTION GROUNDING AND BONDING FOR ELECTRONIC SAFETY AND SECURITY

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION LIGHTNING PROTECTION SYSTEM

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION EARTHING AND EARTH FAULT PROTECTION

SECTION GROUNDING AND BONDING

A. All materials shall be tested and listed by an OSHA approved Nationally Recognized Testing Laboratory (NRTL).

TERWA REBAR CONNECTION COUPLERS

ELECTRICAL SECTION 2

STRUCTURAL STEEL FRAMING

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

GLENWOOD PLACE 2 MAR 2015

CONTENTS. B. System Design and Performance Requirements

SECTION GROUNDING AND BONDING FOR ELECTRICAL SYSTEMS

CARES Technical Approval Report TA1-B 5058

A. Provide a complete Distribution Panelboard system as indicated on the drawings, and as specified herein.

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SPLICE SLEEVE JAPAN, LTD.

1 AND 2 FAMILY DWELLING REQUIREMENTS

TERWA REBAR CONNECTION COUPLERS. CARES Technical Approval 5058 TA1B

PS 3000 Installation Manual Step-By-Step Procedures C.9. DOOR AND WINDOW OPENINGS C.9.1 PREPARE IN ADVANCE. C.9.2 VBUCK CONSTRUCTION.

SECTION (16071) - VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

Aluminum Component Pipe Railings

V 2.0 ASSEMBLY GUIDE. TS Platform Scale Series 2

Effect of Direct Lightning Strike in the Down Conductors Embedded into the Reinforcement

SPECIAL SPECIFICATION 4703 Repair Of Impact Damaged Prestressed Concrete Bridge Beams

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

Site Preparation... 2

SECTION CHAIN-LINK FENCES AND GATES 02821/1

The Hashemite University Department of Civil Engineering. Dr. Hazim Dwairi. Dr. Hazim Dwairi 1

Spring Pressure Connection Technology Vibration-Proof Fast Maintenance-Free

SECTION FACILITY LIGHTNING PROTECTION

RAPID Column Formwork For the highest requirements on concrete surfaces and edge formation. Product Brochure Issue 10/2017

Student Services & Classroom Addition SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

fischer Test Report Fixing Tests for Bison Hollow Core Slabs

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

Repair Maintenance Hangar Phase II August 2010 SECTION LIGHTNING PROTECTION SYSTEM PART 1 GENERAL

SV24. Submittal Special Precautions Specifications Installation. 12½" (31.8 cm) 12½" (31.8 cm) 12" (30.5 cm) 12" (30.5 cm) 12" (30.

INSTEEL WIRE PRODUCTS. Product Catalog

ZG Scope. 2 Applicable Documents. 3 General. 4 Stock Item Numbers. Padvault Single-Phase Residential, 2.1 PacifiCorp Material Specifications

A EN ROUND STORAGE SILO. Ø480cm, Ø560cm, Ø640cm, Ø720cm ASSEMBLY AND USER MANUAL. ARSKAMETALLI LTD

SECTION VIBRATION AND SEISMIC CONTROLS FOR HVAC PIPING AND EQUIPMENT

Raised Basement. Mechanical Installation Guide

2003 International Residential Code ELECTRICAL PROVISIONS ONLY October 2005 EDITORIAL CHANGES SEVENTH PRINTING

PARTICULAR SPECIFICATION E11: GENERAL ELECTRICAL EARTHING AND LIGHTNING PROTECTION

SECTION GROUNDING AND BONDING

Essex County College - West Essex Campus Addition And Renovations dlb # / 11-14

This product specification is written according to the Construction Specifications Institute MasterFormat, 2014 Update.

CARES Technical Approval Report TA1-B 5040

SECTION ENCLOSED BUS ASSEMBLIES

FS-DUO. Wastewater Flow Distributor Technical Data. Submittal Special Precautions Specifications Installation. (62.2 cm) (62.2 cm)

CHAPTER 13 GROUNDING AND BONDING

SECTION ENCLOSED BUS ASSEMBLIES

TECHNICAL MANUAL. TENLOC Panel Connector. Hidden Latch Connection for Precast Panels

SECTION VIBRATION CONTROLS FOR PLUMBING PIPING AND EQUIPMENT

WIRING METHODS CHAPTER 38

DESIGN AND CONSTRUCTION OF HEAVY INDUSTRIAL ANCHORAGE FOR POWER-PLANTS

SECTION PART 1 GENERAL

SECTION ARCHITECTURAL ORNAMENTAL HANDRAILS AND RAILINGS Casino Modular Railing System

SECTION COMMON WORK RESULTS FOR FIRE SUPPRESSION

A. Product Data shall be provided for each type of product indicated.

GGI-750. Gravity Grease Interceptor Technical Data. Submittal Special Precautions Specifications Installation

Kaf-Tech Product Specification

1. Hangers and supports for electrical equipment and systems. 2. Construction requirements for concrete bases.

PV Mounting System 2703 SERIES 200 UL GROUND MOUNT SYSTEM. SnapNrack Residential PV Mounting Systems Code Compliant Installation Manual

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SECTION METAL FLOOR PLATE STAIRS

OVERHEAD SERVICES - SECONDARY

Contents EN :2008+A1:2011 (E) Page

SECTION HANGERS AND SUPPORTS FOR PLUMBING

MSME Testing Centre, 65/1, G. S. T. Road, Guindy, Chennai, Tamil Nadu. Discipline Electrical Testing Issue Date

SECTION CONDUITS AND BACKBOXES FOR COMMUNICATIONS SYSTEMS

SECTION ALUMINUM HANDRAIL SYSTEMS

STANDARDIZED STRUCTURES

NORTHWESTERN UNIVERSITY PROJECT NAME JOB #

Joint Design of Precast Concrete Moment Frame using Hollow Precast Concrete Column Soo-Yeon Seo, Tae-Wan Kim, Jong-Wook Lim, Jae-Yup Kim

SECTION GROUNDING AND BONDING

Fiberstrut Parts Catalogue

BUSWAY LOW VOLTAGE (POW-R-WAY III) SECTION SECTION 16466

Installation Guidelines for Flygt Pumps Pump Anchoring Recommendations

GROUND MOUNT INSTALLATION MANUAL

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

Installation Instructions TrafficLED Levelling Console

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

HALSEY TAYLOR OWNERS MANUAL Classic TM Series Barrier-Free Water Coolers Refrigerated Fountains with Back Panel

Mezzanines By Design Page 1

SECTION GROUNDING

Lattice Plate Flooring

Interior Hangers. Application

Rapid Clamp EUROBUYSERVICES EBS

P R E - I N S U L AT E D PIPE SYSTEMS COMPRESSION WALL SEAL INSTALLATION GUIDE. Compression Wall Seal Installation Guide

Please check with your local inspection authority for any additional requirements before installation.

JGJ Translated English of Chinese Standard: JGJ JGJ NATIONAL STANDARD OF THE

SPECIAL SPECIFICATION 6499 Environmentally controlled Communications Building

Blue-Tip SCREW-BOLT. Ratchet teeth locks head against fixture. Reverse parabolic threads privide high load capacity

fischer Test Report Fixing Tests for

Foundation Specifications for 3.6-/3.7-Meter Earth Station Antennas

Transcription:

Lightning Protection System for PC Buildings Kazuo Hiruma Mechanical & Electrical Design Department Obayashi Corporation Tokyo, Japan hiruma.kazuo@obayashi.co.jp Yoshikane Kojima Mechanical & Electrical Design Department Obayashi Corporation Tokyo, Japan kojima.yoshikane@obayashi.co.jp Keywords lightning protection; lightning connector; PC method; down-conductor I. INTRODUCTION Reinforced concrete (RC) structure buildings constructed using precast concrete (PC) employ mechanical joints to connect the main reinforcing bars within s. In such buildings, there is generally a void space between the mechanical joints and the main reinforcing bars, or between each reinforcing bar, where no electrical connection exists. Obayashi Corporation have therefore exploited the lattice-shape or grid-like structure of the reinforcing bars to develop lightning connectors, thereby making effective use of the building s characteristics to enable protection from lightning. The main reinforcing bars are electrically connected to joints using an intermediary between the connections, thus creating a number of routes for the lightning current to flow and ultimately delivering a highly reliable lightning protection system. The lightning connector was evaluated by the Investigation and Research Committee on the Performance Requirements of Down-Conductors Made of Rebar for Lightning Protection of the Institute of Electrical Installation Engineers of Japan [3]. And the lightning connector meets the requirements for the IEC standard, connection components [5]. II. CONVENTIONAL DOWN CONDUCTORS USED IN PC CONSTRUCTION METHOD A. PC construction method and mechanical joints RC structured high-rise apartment buildings in Japan, in recent years, have been constructed using PC construction methods. This method of building enables a shorter construction period and is thus labor-saving. In PC construction methods, the s and beam members are manufactured at factories, and are then delivered to the site where they are assembled (Fig. 1). As no concrete placement occurs on site, this method uses mechanical joints to connect the reinforcing bars to each other. Of all the various types of mechanical joints, the mortar-grouted joint (Fig. 2) and the threaded-rebar joint (Fig. 3) are more frequently utilized. The mortar-grouted joint involves the insertion of a rebar from and into both sides of a sleeve joint; the void space between the sleeve and rebar is then filled with a high-strength grout to connect both bars using the hardened grout material as an intermediary. Therefore, no electrical connectivity is established between the rebar and sleeve, or between each rebar. The inner diameters at both ends of the joint are different from each other; the smaller end is known as the narrow-end side and the larger end the wide-end side. The rebar on the narrow-end side is fixed by a rubber seal and that on the wide-end side is inserted into the sleeve on site. In addition, the threaded-rebar joint fastens the thread knot of the rebar to the screw thread of the coupler using a torque fixation method or grout fixation method. LR beam (1) LR beam joining LR beam moves left and right Fig. 1. PC construction method (LRV method [1]) Wide-end side Grout port Deformed rebar Grout (3) Floor mounting Fig. 2. Mortar-grouted joint Vertical (2) Vertical joining Narrow-end side Sleeve Grout port

Grout injection hole Coupler Fixing nut Grout Fig. 3. Threaded-rebar joint Threaded rebar B. Conventional method used in installation of down-conductors In the PC construction method using mortar-grouted joints, it is generally not permitted to utilize the main reinforcing bars of s as down-conductors because they are not deemed to be electrically connected. Therefore, the conventional installation method embeds a vinyl chloride pipe in a PC in advance at the factory, and the down-conductor wire is then passed down through the (Fig. 4). However, as the down-conductor is independent of the building s structure, the lightning protection performance is significantly inferior to that within steel-framed or conventional reinforced concrete buildings. In addition, this method is more costly because it requires the work of both PC construction workers and electricians, in accordance with the built-up structure of PC construction. Guard pipes for wiring of down-conductors (to be removed upon completion of wiring) III LIGHTNING PROTECTION SYSTEM USING LIGHTNING CONNECTORS Hard-drawn stranded copper conductors are not connected to the reinforcing bars of the building, and therefore, the conventional method of installing down-conductors cannot utilize the building structure as a down-conductor nor can the structure be used to build a system for internal lightning protection. Therefore, to address this, Obayashi Corporation has devised a system whereby lightning connectors electrically connect the main reinforcing bars with each other. A. Structure of lightning connectors There are two types of lightning connectors as follows: one is used with the wide-end side of the joint and the other with the narrow-end side. The wide-end connector (Fig. 5) is installed on site and is structured so that a metal piece is placed against the inside of a sleeve-shaped joint, which extends to the center and holds the rebar. The narrow-end connector (Fig. 6), which is installed in the factory, is structured to be placed on the outside of the sleeve-shaped joint; it uses a bolt to tighten the center of the metal piece to hold the rebar. These connectors enable the lightning current to flow from reinforcing bars to joints and vice versa. Main reinforcing bar of Lightning connector Vinyl pipe implanted in PC Lead wire Mortar-grouted joint Connected with lead wire by wrapping fixation tape around PC PC Down-conductor wire Hard-drawn stranded copper conductor 2.0 x 13 C Fig. 4. Conventional method used to install down-conductors [2] Fig. 5. Lightning connector (wide-end side) Mortar-grouted joint Lightning connector Main reinforcing bar of Fig. 6. Lightning connector (narrow-end side)

B. Performance of lightning connectors A metal structure used to hold a sleeve-shaped joint or rebar will inevitably produce greater contact resistance than a bolt tightening such as that on the narrow end side. However, in actual PC construction work it is extremely difficult to use the bolt-tightening style to connect the upper and lower main reinforcing bars with each other during the process when the main reinforcing bar (that protrudes from the upper ) is inserted into the joint embedded in the lower. Another disadvantage is that an oxide film forms on the surface of a rebar after it has been exposed to high temperatures during the manufacturing process, and because of its high contact resistance, the oxide film can generally not attain electrical connectivity. To address this, Obayashi Corporation has succeeded, through various trial-and-error efforts, in reducing the contact resistance of lightning connectors to that of the milliohm level, which is comparable to that of commercially-available joint metals. Although the contact resistance of each connector is relatively high, this can be resolved by using main reinforcing bars of multiple s to reduce the electric resistance of the whole building. C. Lightning protection system using lightning connectors The design of the system has a similar structure to that of a bird cage, and the reinforcing bars are connected to each other by the intermediary lightning connectors (Fig. 7). This system is mainly for use in RC structures that employ the PC construction method, and it delivers both external and internal lightning protection. The appropriate number of main reinforcing bars that need to be equipped with lightning connectors varies depending on the grade of each building. In addition, the concept of external lightning protection is extended to include lightning protection on the sidewall of high-rise PC buildings. Furthermore, handrails (Fig. 8) or projection rods on apartment buildings can be utilized as lightning-receiving parts (Fig. 9); if lightning strikes the handrail or projection rod it then flows into the main reinforcing bars of the s through lightning connectors and finally flows out through the foundation of the building to the ground. For internal lightning protection, equalization of electric potential between the floors can be achieved by drawing out a grounding wire from a rebar clamp connected to the main reinforcing bar of the, which is then connected to slab reinforcement (Fig. 10). This works effectively to protect electronic appliances from secondary induced lightning or acts as a grounding point for surge protective devices (SPDs). D. Effects on joint structure performance In Japan, structure methods of rebar joints are specified in a public notice issued by the Ministry of Land, Infrastructure, Transport, and Tourism. It is thus essential to satisfy the requirements of these methods in a building where a lightning current will flow through joints. It is imperative that there is no change in the mechanical property of joints and that no mechanical damage would occur to joints in the event of a lightning current flow. These requirements are reported by the Investigation and Research Committee on the Performance Requirements of Down-Conductors Made of Rebar for Lightning Protection of the Institute of Electrical Installation Engineers of Japan [3]. According to the Committee s evaluation, it is only permissible for rebars and joints that conform to such requirements to allow a lightning current to pass through them. External lightning protection JISA4201-1992 Legend symbol: Power supply Automatic fire alarm To the relay panel Power board/switchboard/dwelling-unit switchboard Receiver SPD Automatic fire alarm Antenna Dwelling-unit switchboard Relay Fig. 7. Lightning protection system using lightning connectors

Lightning-receiving part Connected to reinforcing bar in IV. RESISTANCE OF DOWN-CONDUCTORS USING LIGHTNING CONNECTORS To verify the performance of lightning connectors, we measured the electrical resistance of s used as down-conductors in Building B, where the main reinforcing bars of the s are connected to each other by lightning connectors. A. Measurement method Column's main reinforcing bar Disconnect (on all the measured floors) Conductor Fig. 8. Conceptual figure for lightening protection on sidewall (using handrail) Connect to slab reinforcement Current line Lightning-re ceiving part (decorative metallic bolt) Connected to reinforcing bar in Voltage measurement line Measuring instrument Conductor Fig. 9. Conceptual figure for lightening protection on sidewall (using projection rod) PC Rebar clamp Resistance R = V(V)/A(A) Grounding trunk line Fig. 11. Schematic diagram of obtaining measurements (Building B) We measured the electrical resistance of the s in Building B using the four-terminal method, which employs a low-resistance measuring instrument (Fig. 11 and Fig. 12). Electrical resistance can be determined by transmitting 10A (10 amperes) of direct-current electricity between the third floor (3F) and the twenty-ninth floor (29F) and measuring the voltage between these floors. Slab reinforcement Connect to slab reinforcement on each floor Lightning connector (patent applied for) A2 A1 IH V2 V1 VH Terminal 端子台 block (52F) VH IH PC beam Column 柱 2 2 柱 1Column 1 Measuring 測定器 instrument V1 V2 VL VL IL A1 A2 IL Terminal 端子台 block (3F) (3F) Grounding wire ED Reinforcing bar Mechanical joint PC Fig. 10. Equalization of electric potential between floors Fig. 12. Measurement circuit and low-resistance measuring instrument B. Results of measurement Table I shows the results of electrical resistance measurements recorded on s between the 3F and 29F

of Building B. The calculated values show results determined on the assumption that a parallel circuit is working effectively between each pair of s. TABLE I. ELECTRICAL RESISTANCE MEASUREMENT RESULTS Measured Column (Building B: 29-storey building) Measurement Value Column 1 28.300 mω (1) Column 2 33.420 mω (2) Column 3 39.950 mω (3) Column 4 34.170 mω (4) Calculated Value Columns 1 & 2 parallel 20.160 mω 15.430 mω Columns 1 & 3 parallel 17.350 mω 17.063 mω Columns 1 & 4 parallel 17.186 mω 15.618 mω Columns 2 & 3 parallel 25.619 mω 18.343 mω Columns 2 & 4 parallel 25.955 mω 16.898 mω Columns 3 & 4 parallel 18.901 mω 18.530 mω C. Discussion In this section, we first attempt to calculate the electrical resistance of one reinforcing bar of Column 1. The electrical resistance per bar on floors from 3F to 29F is Reinforcing bar 56.32 m x 0.193 mω + joint part (including the bar) 26 locations x 1.363 mω + measuring wire 6.0 m x 0.824 mω/m = 51.3 mω. (7), Calculation conditions: where 56.32 m = 85.7 m 26 x 1.13 m. Total length of the reinforcing bar D41 is 85.7 m Resistance of the reinforcing bar D41 is 0.193 mω/m Resistance of joint part (bar + joint) is 1.363 mω/1.13 m, which is the resistance value of a test object connected by the connector Resistance of IV5.5 measuring wire is 0.824 mω/m Table 1 shows that the measured resistance values of single reinforcing bars from (1) to (4) are all small, ranging from 55 to 80% of the calculation value in Eq. (7), which is 51.3 mω. We presume that this result was reached because the s have a large number of reinforcing bars connected by hoops. However, the parallel-circuit values between two s in Table 1 are between one third (1/3) and one half (1/2) of the calculation value shown in Eq. (7). Such differences are caused by resistance of the measuring wires; lengths of the wires differ between the measuring instrument and each. We then attempt to estimate the total resistance between the third floor (3F) and the twenty-ninth floor (29F), where, in the case of Building B, which has 42 s, {(1) + (2) + (3) + (4)}/4/42 = 0.80 mω. Therefore, assuming a safety factor of 10, the resistance is 8.0 mω. This result is considerably lower than 0.2 Ω (200 mω), which is the target value for the overall resistance of a building that is defined in the International Electrotechnical Commission (IEC) standard 62305-3 [4] as applicable for use as a down-conductor. This result therefore means that the building itself can be utilized as a down-conductor for lightning protection, even if it is constructed by the PC construction method, as long as the main reinforcing bars in the s are connected to each other securely using connectors or other appropriate means. V. CONCLUSION It is possible to utilize the main reinforcing bars of RC structures constructed using the PC construction method as down-conductors in an external lightning protection system, if electrical connectivity can be established between the main reinforcing bars. In addition, by structuring the reinforcing bars within the building in the shape of a bird cage, with the aim of equalizing electric potential throughout the building, the actual structure of the building can also be utilized as an internal lightning protection system. VI. FUTURE CHALLENGES It is not possible to gain measurements of the electrical resistance of a high-rise building during construction, because when the concrete is being placed on the upper floors the interior finishing work has already begun on the lower floors. Therefore, to measure resistance it is necessary to install measuring wires in advance, and this needs to occur before the finishing work is begun in relevant areas. In projects with a tight time schedule, it would thus be necessary to allow for sufficient preparation and setup, in addition to gaining prior consent from the building constructors. We therefore hope for the emergence or development of an estimation method that enables the omission of measurements, or of a simplified method for use in measuring a building s resistance. REFERENCES [1] K. Kano, N. Fujiu, Y. Masuda, and I. Ishikawa, Construction of high rise R/C residential building by new precast method, Concrete Journal, Japan Concrete Institute, vol. 44, No. 8, August 2006. [2] Y. Takayama: Sleeve-pipe construction method for down conducting wires for lightning protection in layered PC s, Building Mechanical and Electrical Engineer journal, pp. 35 37, March 2007. [3] K. Hiruma et al, Performance of reinforcing-steel with joints for down-conductors and resistance of a building where rebar and joints were connected by connectors, ICLP2014. [4] IEC62305-3 Edition 2.0 2012-12 Protection against lightning-part 3: Physical damage to structures and life hazard. [5] IEC62561-1 Edition 1.0 2012-02 Lightning protection system components -Part1:Requirements for connection components.