DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

Similar documents
ICC-ES Report OR-4, AND MOISTURE DIVISION: SECTION: SECTION: Reissued 11/2017 This. Report Holder:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE RUBBER SHAKES REPORT HOLDER: DAVINCI ROOFSCAPES, LLC

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL SHINGLES REPORT HOLDER: TEFUTE BUILDING MATERIALS COMPANY, LLC

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

REPORT HOLDER: LOUISIANA-PACIFIC CORPORATION 414 UNION STREET, SUITE 2000 NASHVILLE, TENNESSEE EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOF PANELS REPORT HOLDER: ONDULINE NORTH AMERICA, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING FELT AND UNDERLAYMENT REPORT HOLDER: ENVIRONMENTALLY SAFE PRODUCTS, INC.

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: MODIFIED BITUMINOUS SHEET ROOFING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

REPORT HOLDER: FEROOF CO., LTD SEONWON LI SEONNAM MYEON SUNGJU GUN KYEONGSANGBUK DO SOUTH KOREA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FACED PANELS REPORT HOLDER: MEXALIT INDUSTRIAL, S.A. DE C.V.

Trusted ICC ES POST MODELS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: PLY GEM SIDING GROUP EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: BORAL COMPOSITES, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: ROOF PANELS REPORT HOLDER: ROSER CO., LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: DERBY BUILDING PRODUCTS INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: INTEPLAST GROUP CORPORATION EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: UTILITIES SECTION: SUBDRAINAGE REPORT HOLDER: ROYAL BUILDING PRODUCTS (USA) INC.

ESR-1061 Reissued May 1, 2011 This report is subject to renewal in two years.

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH BRAND FASTENERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: REFLECTIX INCORPORATED

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

ESR-2015P* Reissued April 2014 This report is subject to renewal April 1, 2015.

REPORT HOLDER: THE DOW CHEMICAL COMPANY 1501 LARKIN CENTER DRIVE MIDLAND, MICHIGAN EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

ESR-3284 Reissued August 1, 2011 This report is subject to renewal August 1, 2013.

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

REPORT HOLDER: PAREX USA, INC EAST LA PALMA AVENUE, SUITE 250 ANAHEIM, CALIFORNIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

Trusted ICC ES DIVISION: 07 LTD. PLASTI FAB CANADAA PLASTISPAN. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF TILES REPORT HOLDER: GERARD ROOFING TECHNOLOGIES EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: PASLODE, AN ILLINOIS TOOL WORKS COMPANY

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

REPORT HOLDER: OMEGA PRODUCTS INTERNATIONAL, INC CALIFORNIA AVENUE CORONA, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: HUBER ENGINEERED WOODS, LLC ONE RESOURCE SQUARE DAVID TAYLOR DRIVE, SUITE 300 CHARLOTTE, NORTH CAROLINA 28262

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: HY-TEK FASTENERS INC. EVALUATION SUBJECT: HY-TEK NAILS

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: AIR BARRIERS REPORT HOLDER:

REPORT HOLDER: GEORGIA PACIFIC GYPSUM LLC 2861 MILLER ROAD DECATUR, GEORGIA EVALUATION SUBJECT: DENSELEMENT BARRIER SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

REPORT HOLDER: CARLISLE SYNTEC POST OFFICE BOX 7000 CARLISLE, PENNSYLVANIA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

ICC ES SYSTEM SYSTEM. Trusted DIVISION: 07 SECTION: AND FINISH REPORT HOLDER: ICC-ES Evaluation. Reissued 08/2016.

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: SUZHOU HONGLY HARDWARE CO., LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: LAMINATED VENEER LUMBER REPORT HOLDER: REDBUILT LLC EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: CHEMICAL BROTHERS INTERNATIONAL, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I-JOISTS REPORT HOLDER: PACIFIC WOODTECH CORPORATION

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC EVALUATION SUBJECT:

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 2664 Reissued 08/2017 This report is subject to renewal 08/2019. DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION SECTION: 07 72 26 RIDGE VENTS REPORT HOLDER: VERSCENE, INC. 705 PENNSYLVANIA AVENUE SOUTH MINNEAPOLIS, MINNESOTA 55426 EVALUATION SUBJECT: VERSCENE QUARRIX RIDGE VENTS, TRIMLINE AND TRIMLINE PLUS RIDGE VENTS, TRIMLINE CUSTOM SERIES WITH STORMSTOP AND OWENS CORNING VENTSURE RIDGE VENTS Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report www.icc-es.org (800) 423-6587 (562) 699-0543 ESR-2664 Reissued August 2017 This report is subject to renewal August 2019. A Subsidiary of the International Code Council DIVISION: 07 00 00 THERMAL AND MOISTURE PROTECTION Section: 07 72 26 Ridge Vents REPORT HOLDER: VERSCENE, INC. 705 PENNSYLVANIA AVENUE SOUTH MINNEAPOLIS, MINNESOTA 55426 (800) 438-2920 www.verscene.com deankruchten@verscene.com EVALUATION SUBJECT: VERSCENE QUARRIX RIDGE VENTS, TRIMLINE AND TRIMLINE PLUS RIDGE VENTS, TRIMLINE CUSTOM SERIES WITH STORMSTOP AND OWENS CORNING VENTSURE RIDGE VENTS ADDITIONAL LISTEE: OWENS CORNING ONE OWENS CORNING PARKWAY, 1C TOLEDO, OHIO 43659 (419) 248-7060 www.owenscorning.com 1.0 EVALUATION SCOPE Compliance with the following codes: 2015, 2012, and 2009 International Building Code (IBC) 2015, 2012, and 2009 International Residential Code (IRC) Properties evaluated: Ventilation of attic spaces Weather resistance Wind uplift resistance 2.0 USES The Quarrix, Trimline and VentSure ridge vents are installed in conjunction with eave, cornice, and soffit vents to provide natural ventilation of enclosed attic and rafter spaces. 3.0 DESCRIPTION 3.1 Ridge Vents: The vents consist of multiple layers of corrugated polyethylene, classified as CC2 plastic under IBC Section 2606.4. The vents are available in standard profiles (six corrugated layers) and low profiles (four corrugated layers). The low-profile vents are available in both fold-out and rigid-roll styles and may have a spun-bound polypropylene membrane adhered on the inside face. 3.2 Net-free Ventilation Area: The net-free ventilation area is 19 square inches (123 cm 2 ) per lineal foot (305 mm) of vent, for the standard profile vents, and is 12.7 square inches (82 cm 2 ) per lineal foot (305 mm) of vent for the low-profile vents. See Table 1 for dimensions and product names. 4.0 INSTALLATION 4.1 General: A 2-inch-wide (51 mm) slot is cut in the sheathing at the ridge, 1 inch (25.4 mm) on each side of the ridge, leaving a minimum of 6 inches (152 mm) of the sheathing inside the exterior wall line at each end. For roofs with a ridge board, a 3 1 / 2 -inch-wide (88.9 mm) slot is cut in the sheathing at the ridge, 1 3 / 4 -inch (44.4 mm) on each side of the ridge board. A minimum of 6 inches (152 mm) of the roof sheathing at each end of the roof shall be left uncut. Table 2 provides a summary of the width of the slot measured along the roof slope from the ridge to the edge of the slot. The ridge vents are centered over the ridge and attached to sheathing by means of two nails on each end of the vent, one nail on each side of the ridge line. On 4-foot-long (1219 mm) ridge vents, the nails are spaced at a maximum of 46 inches (1168 mm) on center, 1 inch (25.4 mm) from each end. On longer vents, the nails are located 1 inch (25.4 mm) from each end and are spaced at a maximum of 48 inches (1219 mm) on center. The nails must be 0.125-inch-diameter-shank (3.2 mm), galvanized roofing nails with 0.385-inch-diameter (10 mm) heads and a minimum length such that the nails penetrate the sheathing a minimum of 3 / 4 inch (19.1 mm), or through the thickness of the sheathing, whichever is less. The ridge vents must be covered with asphalt ridge shingles or wood ridge shakes that are attached to the roof structure by means of fasteners consistent with the fasteners used to attach the roof coverings without roof vents, but with increased fastener length to provide the minimum nail penetration. Exposed ends of the ridge vents must be sealed as described in the manufacturer s instructions. See Figures 1 3 for typical installation details. 4.2 Wind Resistance: 5.0 CONDITIONS OF USE Under the 2015 IBC and IRC, and 2012 IBC, when installation is in accordance with this report, the ridge vents ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2017 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

ESR-2664 Most Widely Accepted and Trusted Page 2 of 4 are limited to use in areas subject to a maximum ultimate design wind speed of 130 mph (209 km/hr) on structures having a mean roof height of 40 feet (12.2 m) or less in Exposure D areas. Under the 2009 IBC, 2012 IRC and 2009 IRC, when installation is in accordance with this report, the ridge vents are limited to use in areas subject to a maximum basic wind speed of 100 mph (161 km/hr) on structures having a mean roof height of 40 feet (12.2 m) or less in Exposure D areas. The Verscene, Inc., Quarrix Ridge Vents, Trimline and Trimline Plus Ridge Vents, and Owens Corning VentSure Ridge Vents described in this report comply with, or are suitable alternatives to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 The ridge vents are installed in accordance with this report and the manufacturer s instructions. In the event of a conflict between the manufacturer s instructions and this report, this report governs. 5.2 The ridge vents shall not be used in the construction of Occupancy Groups H, I-2, or I-3. 5.3 The ridge vents are installed on roofs having a minimum slope of 3:12 (25% slope). 5.4 The ridge vents must be installed only on roofs upon which a non-classified roof covering is permitted unless the following conditions are met: 5.4.1 The building is equipped throughout with an automatic sprinkler system in accordance with IBC Section 903.3.1.1. 5.4.2 The maximum area of a continuous ridge vent is 100 sf (9.29 m 2 ) and the aggregate area of the vents and any light-transmitting roof panels must not exceed 25 percent of the floor area served. 5.4.3 The vents must not be installed within 6 feet (1.8 m) of any exterior wall required by Section 705.8 of the IBC to have protected wall openings. 5.5 Wind resistance of the ridge vents is limited to those areas described in Section 4.2 of this report. 5.6 Roof diaphragm nailing requirements of the applicable code must be addressed, and the vent installation must be approved by the building official. 6.0 EVIDENCE SUBMITTED Data in accordance with the ICC-ES Acceptance Criteria for Attic Vents (AC132), dated February 2010, editorially revised May 2016. 7.0 IDENTIFICATION Labels on packages of ridge vents bear the Verscene, Inc. or Owens Corning company name and address, the product name (Quarrix Trimline or VentSure ), the model designation, and the evaluation report number (ESR-2664). Each individual vent is either identified by a label that bears the Verscene, Inc. or Owens Corning company name and address, the Quarrix Trimline or VentSure product name, and the model designation; or is embossed with the product name and type of vent. PROFILE WIDTH (inches) TABLE 1 TRIMLINE AND VENTSURE DESCRIPTIONS LENGTH (feet) PRODUCT NAME Standard Profile 9 and 11 1 / 4 4 and 8 Trimline Standard Low Profile Foldout 7, 9 and 11 1 / 4 4 and 8 Quarrix Rigid Vent,Trimline Low Profile Trimline Ridge Vent Plus Trimline Rigid Vent Custom Series with StormStop Owens Corning VentSure Low Profile Owens Corning VentSure with Weather Protector Low Profile Rigid Roll 7, 9 and 11 1 / 4 20 and 50 Quarrix Rigid Roll, Trimline Rigid Roll and Trimline Rigid Roll Plus Trimline Rigid Roll Custom Series with StormStop 20 and 50 Owens Corning VentSure Roll Owens Corning VentSure Rigid Roll with Weather Protector For SI: 1 inch = 25.4 mm, 1 foot = 304.8 mm, 1 in. 2 /lin. Ft. = 2117 mm 2 /m. 1 See Figure 1 or additional data. TABLE 2 WIDTH OF SLOT MEASURED ALONG THE SLOPE FROM THE RIDGE TO THE EDGE OF THE SLOT ROOF PITCH (DEGREES) WIDTH OF SLOT MEASURED FROM THE RIDGE ALONG THE ROOF SLOPE (IN) No Ridge Board Ridge Board 3:12 (14.0) 1 1 7 / 8 4:12 (18.4) 1 1 / 8 1 7 / 8 6:12 (26.6) 1 1 / 8 2 8:12 (33.7) 1 1 / 4 2 1 / 8 10:12 (39.8) 1 3 / 8 2 3 / 8 12:12 (45) 1 1 / 2 2 1 / 2 16:12 (53.1) 1 3 / 4 3

ESR-2664 Most Widely Accepted and Trusted Page 3 of 4 FIGURE 1

ESR-2664 Most Widely Accepted and Trusted Page 4 of 4 FIGURE 2 FIGURE 3