Seismic Performances of Brick Masonry Inverted Bell-Shaped Chedi

Similar documents
Seismic Strengtheningof Heritage Structure in Mandalay

A Comparative Study on the Seismic Behavior of Ribbed, Schwedler, and Diamatic Space Domes by Using Dynamic Analyses

Linear and Nonlinear Seismic Analysis of a Tall Air Traffic Control (ATC) Tower

REINFORCED CONCRETE WALL BOUNDARY ELEMENT LONGITUDINAL REINFORCING TERMINATION

COMPARISON BETWEEN SEISMIC RESPONSES OF ANCHORED AND UNANCHORED CYLINDRICAL STEEL TANKS

LONGITUDINAL RESPONSE OF POWER TRANSMISSION TOWER-CABLE SYSTEM TO TRAVELING WAVE

VERTICAL COMPONENT EFFECT OF EARTHQUAKE IN SEISMIC PERFORMANCE OF REINFORCED CONCRETE BRIDGE PIERS

Studying the effects of earthquakes near and far fault region on seismic behavior of dual frame equipped with viscous damper

SELECTION AND SCALING OF GROUND MOTION RECORDS FOR SEISMIC ANALYSIS

Development of Analytical Fragility Curves for Cylindrical Steel Oil Tanks

Earthquake Response Analysis of Spherical Tanks with Seismic Isolation

Case Study: Challenges of a Single-layer Reticulated Dome

Types : Metal rockers, rollers or slides or merely rubber or laminated rubber, POT - PTFE

Performance-Based Seismic Evaluation of Wind-Impacted Tall Buildings

Chapter 7. Finite Elements Model and Results

FINITE ELEMENT ANALYSIS OF REINFORCED CONCRETE BRIDGE PIER COLUMNS SUBJECTED TO SEISMIS LOADING

EVOLUTION OF UBC AND IBC STATIC LATERAL FORCE PROCEDURE

PERFORMANCE OF CYLINDRICAL LIQUID STORAGE TANKS IN SILAKHOR, IRAN EARTHQUAKE OF MARCH 31, 2006

PSEUDO-DYNAMIC TEST AND NON-LINEAR ANALYSIS OF A 1:10 SCALE PRE-STRESSED CONCRETE CONTAIN VESSEL MODEL FOR CNP1000 NUCLEAR POWER PLANT

Influence of Vertical Acceleration on Seismic Response of Endbearing

FINITE ELEMENT AND LIMIT ANALYSIS OF THE LARGE SCALE MODEL OF MUSTAFA PASHA MOSQUE IN SKOPJE STRENGTHENED WITH FRP

EFFECTS OF STRONG-MOTION DURATION ON THE RESPONSE OF REINFORCED CONCRETE FRAME BUILDINGS ABSTRACT

Nonlinear Dynamic Analysis of Base Isolated Reinforced Concrete Building

EVALUATION OF SEISMIC BEHAVIOR OF IRREGULAR STEEL STRUCTURES IN PLAN WITH BRB AND EBF BRACES UNDER NEAR-FAULT EARTHQUAKE

Earthquake Design of Flexible Soil Retaining Structures

Numerical Analysis of the Influence of Geometry of Ceramic Units (Blocks) on Structural Walls

beni-suef university journal of basic and applied sciences 5 (2016) Available online at ScienceDirect

STRUCTURAL APPLICATIONS OF A REINFORCED CONCRETE BEAM-COLUMN-SLAB CONNECTION MODEL FOR EARTHQUAKE LOADING

Dynamic Stability of Elastomeric Bearings at Large Displacement

Methodology for the seismic assessment of face-loaded unreinforced masonry walls and parapets

APPROACHES FOR THE REDUCTION OF THE DISPERSION OF INCREMENTAL DYNAMIC ANALYSIS (IDA) CURVES

Behaviour of MRF Structures Designed According to IRAN Seismic Code (2800) Subjected to Near-Fault Ground Motions.

INELASTIC SEISMIC RESPONSE ANALYSES OF REINFORCED CONCRETE BRIDGE PIERS WITH THREE-DIMENSIONAL FE ANALYSIS METHOD. Guangfeng Zhang 1, Shigeki Unjoh 2

EVALUATION OF NONLINEAR STATIC PROCEDURES FOR SEISMIC DESIGN OF BUILDINGS

The applicability of Direct Displacement-Based Design in designing concrete buildings located in near-fault regions

Seismic Behavior of Persian Brick Arches

REINFORCED CONCRETE BUILDINGS OF SEISMIC BEHAVIOR UNDER SIGNIFICANCE OF FLUCTUATING FREQUENCY

RESPONSE OF GROUND SUPPORTED CYLINDRICAL TANKS TO HARMONIC LOADING

Seismic Performance Of R C Flat-Slab Building Structural Systems

Rong He School of Civil Engineering and Communication, North China University of Water Resources and Electric Power, Zhengzhou, , China

Seismic Evaluation of Steel Moment Resisting Frame Buildings with Different Hysteresis and Stiffness Models

SEISMIC RESPONSE ANALYSIS OF VERTICALLY IRREGULAR RC BUILDINGS USING LAMINATED RUBBER BEARING

The Effects of Building Parameters on the Modal Displacement Shapes of Tall Buildings

DYNAMIC RESPONSE ANALYSIS OF THE RAMA 9 BRIDGE EXPANSION JOINT DUE TO RUNNING VEHICLE

Seismic Response of Simply Supported Deck Bridges with Auxiliary Superelastic Devices

Seismic Analysis and Design of Vertically Irregular RC Building Frames

Study on Improvement of Seismic Performance of Transmission Tower Using Viscous Damper

Using friction dampers for improving earthquake response of self-variable stiffness RC framed buildings

International Journal of Engineering and Techniques - Volume 4 Issue 2, Mar Apr 2018

Parametric Analysis of the Combination of Rubber and Sliding Bearings for Seismic Isolation of Steel Structures

Free Vibration and Modal Analysis of Tower Crane Using SAP2000 and ANSYS

INFLUENCE OF HORIZONTAL OFFSETS OF OPENINGS IN SINGLE STORY BRICK MASONRY BUILDINGS UNDER SEISMIC FORCES

A new approach for the Seismic Isolation Methods for Ancient Statues Displayed in Base Isolated Museums

This point intends to acquaint the reader with some of the basic concepts of the earthquake engineer:

SEISMIC RESPONSE STUDY OF MONOPILE AND SUCTION PILE FOUNDATION FOR OFFSHORE WIND TURBINES

EFFECT OF VERTICAL MOTION OF EARTHQUAKE ON RC BRIDGE PIER

Floating Type Isolation System Using Earthquake Early Warning

ANALYSIS OF A SQUAT CONCRETE WALL, DIFFERENCE IN TRANSLATION DURING SEISMIC EXCITATION DUE TO FOUNDATION SUPPORT. ABSTRACT

COMPARISON OF DIFFERENT METHODS FOR SEISMIC RETROFIT OF BRIDGES USING SMART MATERIALS

Example 8 - Hopkinson Bar

EFFECT OF HARDENING OF LEAD-RUBBER BEARINGS ON NONLINEAR BEHAVIOUR OF HIGHWAY VIADUCTS UNDER GREAT EARTHQUAKES

Keywords: Seismic response, Conical tanks, Finite-Boundary element, Fluid-structure interaction.

NUMERICAL EXAMINATION OF DIFFERENT MASONRY STRENGTHENING METHODS

Non-linear Time History Response Analysis of Low Masonry Structure with tie-columns

Application of Steel Braced Frames for Areas with Moderate Seismic Risks

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Effect of Geometry of Vertical Rib Plate on Cyclic Behavior of Steel Beam to Built-up Box Column Moment Connection

RESILIENT INFRASTRUCTURE June 1 4, 2016

Seismic Collapsing Process Analysis of One-story Thatched Roof Wooden Structure under Strong Earthquake Ground Motion

CONSIDERATION OF NEAR-FAULT GROUND MOTION EFFECTS IN SEISMIC DESIGN

Damage assessment of hollow core reinforced and prestressed concrete slabs subjected to blast loading

SEISMIC DESIGN OF STRUCTURE

Seismic analysis of dry stone masonry structures based on combined finite-discrete element method

Evaluation of Seismic Behavior for Low-Rise RC Moment Resisting Frame with Masonry Infill Walls

SEISMIC CRACKING AND STRENGTHENING OF CONCRETE GRAVITY DAMS

Transactions on the Built Environment vol 20, 1996 WIT Press, ISSN

SEISMIC BEHAVIOR OF STEEL RIGID FRAME WITH IMPERFECT BRACE MEMBERS

Title. Author(s)BAI, DI; HAYASHIKAWA, T.; MATSUMOTO, TAKASHI; HE, XI. Issue Date Doc URL. Type. Note. File Information

Finite Element Model Calibration of An Instrumented Thirteen-story Steel Moment Frame Building in South San Fernando Valley, California

Inelastic Versus Elastic Displacement-Based Intensity Measures for Seismic Analysis

Dynamic interaction of adjacent tall building structures on deep foundations

SEISMIC COLLAPSING BEHAVIOUR OF ONE-STORY WOODEN STRUCTURE WITH THATCHED ROOF UNDER STRONG EARTHQUAKE GROUND MOTION

Available online at ScienceDirect. Procedia Engineering 144 (2016 )

Ground Motion Selection and Scaling Approach for Evaluation of Reinforced Concrete Frames against Sideway Collapse

INELASTIC SEISMIC PERFORMANCE OF RC TALL PIERS WITH HOLLOW SECTION

CHAPTER 3 IMPROVEMENT OF DYNAMIC CHARACTERISTICS OF CUTTING TOOL SYSTEM USING VISCOELASTIC DAMPER

Dynamic Response of Ground Supported Rectangular Water Tanks to Earthquake Excitation

SHAKE TABLE TESTS OF RC FRAME WITH SHAPE MEMORY ALLOY BRACING BARS

REHABILITATION OF RC BUILDINGS USING STRUCTURAL WALLS

Influence of Concrete and Steel outrigger and belt truss in high rise Moment Resisting Frames

3-D finite element analysis on shear lag effect of curved box girder under multi-dimensional seismic excitation

International Journal of Engineering Trends and Applications (IJETA) Volume 5 Issue 5, Sep-Oct 2018

Dynamic Analysis of High Rise Seismically Isolated Buildings

SEISMIC RESPONSE OF A REINFORCED CONCRETE ARCH BRIDGE

Bridge seismic design competition. Organized by

Repair and Retrofit of a 17 th Century Library Structure in Istanbul

A CASE STUDY OF PERFORMANCE-BASED SEISMIC EVALUATION AND RETROFIT OF AN EXISTING HOSPITAL BUILDING IN CALIFORNIA, U.S.

Corrugate Fiber Reinforced Plastic Sheet in Repairing Tunnel Linings

Comparative Study of Multi-storeyed RC Building With Open Ground Storey Having Different Type Infill Walls

INNOVATIVE DESIGN AND TESTING OF A SEISMIC RETROFITTED STEEL DECK TRUSS BRIDGE

Transcription:

Available online at www.sciencedirect.com ScienceDirect APCBEE Procedia 9 (2014 ) 217 221 2013 5th International Conference on Chemical, Biological and Environmental Engineering (ICBEE 2013) 2013 2nd International Conference on Civil Engineering (ICCEN 2013) Seismic Performances of Brick Masonry Inverted Bell-Shaped Chedi Chayanon Hansapinyo Department of Civil Engineering, Chiang Mai University 50200, THAILAND Abstract This research is aimed to perform seismic evaluation of an esteemed brick masonry inverted bell-shaped chedi at Phrathat Doi Suthep temple, Chiangmai, Thailand, by using the finite element analysis. The validated finite element model has been made through the full-scale ambient vibration tests (presented in the accompanied paper). First, twenty past earthquake records were selected and matching of the records to the seismic response spectrum was made for equating the local seismic conditions. Then, the matched seismic waves were used for the input of time history analyses. The results have shown that, the top of the pagoda was very sensitive to the seismic waves. It was deformed significantly, accelerations were amplified and the material was damaged by over-tensioning. 2014 2013 Chayanon Published Hansapinyo. by Elsevier Published B.V. by Selection Elsevier B.V. and/or peer review under responsibility of Asia-Pacific Selection Chemical, and Biological peer review & under Environmental responsibility of Engineering Asia-Pacific Chemical, Society Biological & Environmental Engineering Society Keywords: Time history analysis, Pagoda, Finite element 1. Introduction As stated in the accompanied paper named Ambient Vibration Tests and Finite Element Analysis for Dynamic Properties of Brick Masonry Inverted Bell-Shaped Chedi, Pagoda or a general term Chedi for Thais, is one of such a kind of the historical buildings having solid inverted bell shaped geometry with no interior space in typical. The geometrical dimension utilizes his self-weight enabling the brittle brick masonry material to be efficiently adopted with compressive-arch transferring mechanism under gravity loading, but not for the case of earthquake induced tension. The historical records have shown that the Northern region of Corresponding author. E-mail address: chayanon@eng.cmu.ac.th 2212-6708 2014 Chayanon Hansapinyo. Published by Elsevier B.V. Selection and peer review under responsibility of Asia-Pacific Chemical, Biological & Environmental Engineering Society doi:10.1016/j.apcbee.2014.01.039

218 Chayanon Hansapinyo / APCBEE Procedia 9 ( 2014 ) 217 221 Thailand can be identified as a seismic prone area. As seen in Fig. 1a, the AD.1545earthquake hit Chiangmai city causing failure of top part of Chedi Luang. The total height of the building was dropped from 86 m. to 50 m. at present [1]. Recently, the 6.8 Richter earthquake at Shan State, Myanmar around the Thailand-Myanmar border made the top part of Prathat Chedi Luang, in Chiang san with about 100 km from the source, fallen down. The failure of the buildings exampled above indicate seismic vulnerability of the buildings and evaluation for seismic safety and strengthening are extremely needed. In this paper, Chedi at Phrathat Doi Suthep temple shown in Fig. 2 was selected as a case study. The Chedi is one of the top sacred sites to Thai people located on Suthep Mountain, Chiangmai city, Thailand. The validated finite element model through the full-scale ambient vibration, presented in the accompanied paper, was used for the seismic analyses. Twenty past seismic waves were used for the time history analyses. Current Past Failed Failure of the top Fig. 1. Earthquake damage of Chedis; (a) Chedi Luang, Chiangmai [1] (b) Prathat Chedi Luang, Chiang san Many-tiered umbrella Top spherical cone 22.35 m. Inverted bell shape part Twelve-sided regular polygon upper bases Square shaped lower base Fig. 2. Chedi Phrathat Doi Suthep; (a) Photo (b) Elevation (c) Finite element model 2. Finite element model and input ground motions 2.1. Finite element model The esteemed masonry inverted bell-shaped chedi at Phrathat Doi Suthep temple has square lower base with 10.25 m. in width and upper bases below the inverted bell is twelve-sided regular polygon. Overall height is 22.35 m (excluding the height of many-tiered umbrella). With the complicated geometry and large number of elements, the study adopted the continuous modelling technique. Microscopic behavior considering interaction of composite mechanic was macroscopically assumed with a homogeneous elastic material. The commercial finite element package ANSYS program [2] was used in the three dimensional finite element model adopting 3D solid brick element coded SOLID45. The analysis was based on linear behavior with isotropic property assumption. The many-tiered umbrella at the topmost part (see Fig. 2) was modelled using

Chayanon Hansapinyo / APCBEE Procedia 9 (2014 ) 217 221 219 three dimensional hollowed pipe element coded PIPE45 representing the vertical steel bar. Three lumped masses were assumed representing the weight of 35 kg. The model is comprised of 56,506 solid elements with 11,970 nodes. Material properties used in the analysis are tabulated in Table 1 Table 1. Material properties Properties Masonry Steel Young modulus (GPa) 1.0 200 Poison s ratio 0.15 0.3 Unit weight (kg/m3) 1,800 7,850 Ultimate compressive strength (MPa) 2.68 235 Ultimate tensile strength (MPa) 0.27 235 2.2. Input ground motions The study adopted the time history analysis to evaluate seismic performance of the Chedi. The earthquake excitations were obtained by considering seismic hazard in the area based on the data from the department of mineral resources, Thailand, and seismic hazard evaluation in the area [3]-[5] with the peak ground acceleration with 2% probability of exceedance in 50 years return period. However, there are no any earthquake records in the past consistent with the above seismic intensity. Hence, twenty earthquake records from other locations were considered. To simulate different characteristics of motions, the records can be classified into 3 groups as I. Near-fault ground motions with forward directivity, II. Near-fault ground motions with fling and III. Far-fault ground motions, as shown in Table 2. To consider the effect of site geological response, the response spectrum of the earthquake excitation was matched with the earthquake response spectrum based on DPT seismic load estimation method of the Thai Standard for earthquake design in the studied area [6]. First, the response spectrum of the ground motions were created and matched with the standard response spectrum for the seismicity in the area. Then, the matched ground motions were established. Fig. 3 shows, Loma Prieta (P0770) as an example, the matched response spectrum and the corresponding adjusted earthquake time history for the ground motion excitation. 2.0 Actual spectrum 0.6 Actual motion (solid line) Acceleration (g) 1.5 1.0 0.5 0-0.3 Matched spectrum DPT spectrum -0.6 1.0 2.0 3.0 4.0 5 10 15 Period (Sec.) Fig. 3. Matching of Loma Prieta (P0770); (a) Response spectrum (b) Motions Acceleration (g) 0.3 0 Matched motion (dotted line) 20 25 30 35 40 Time (Sec.) 3. Results Under the gravity load, the structure was quite stable in which self-weight of the solid structure makes the stress state of the material was mainly in compression. The maximum compressive stress was about 0.20 MPa at the twelve-sided regular polygon upper base part where the bearing area is the smallest. There was a little

220 Chayanon Hansapinyo / APCBEE Procedia 9 ( 2014 ) 217 221 magnitude of tensile stress in the surface near the bottom part of the inverted bell shaped body. The tensile stress was in the hoop direction with magnitude much less than the tensile strength. However, due to the vibration caused by wind load with gradually environmental deteriorated strength may lead to small damage and more rapid degradation. Table 2. Input ground motions and results Ground motions Max Lateral Displacement (mm) Maximum Stresses (MPa) Compression Tension Maximum Accelerations (m/s 2 ) I. Near-fault ground motions with forward directivity 1. Imperial-valley (P0177) 16.3-0.47 0.18-11.86 11.18 2. Morgan Hill (P0449) 28.2-0.34 0.34-18.40 17.00 3. Loma Prieta (P0736) 19.7-0.31 0.18-13.46 15.80 4. Loma Prieta (P0770) 20.2-0.30 0.24-20.36 18.25 5. Erzincan (P0802) 24.6 --0.47 0.30-19.49 16.39 6.Cape Mendocino (P0809) 25.0-0.47 0.05-13.15 10.39 7.Northridge (P1005) 30.1-0.39 0.33-14.86 17.85 8.Northridge (P0963) 20.2-0.39 0.28-8.93 11.24 9.Kobe (P1043) 29.5-0.23 0.14-12.14 9.94 10.Kobe (P1057) 29.7-0.42 0.30-16.59 15.46 II. Near-fault ground motions with fling 11.Kocaeli (P1109) 22.4-0.41 0.24-18.34 14.79 12.Chi Chi (TCU068) 16.4-0.57 0.27-10.65 11.47 13. Chi Chi (TCU072) 23.9-0.34 0.24-15.45 11.83 14.Chi Chi (TCU074) 24.7-0.34 0.26-13.67 11.10 15.Chi Chi (TCU076) 21.7-0.47 0.27-12.15 9.99 III. Far-fault ground motions 16.Kern country (P0016) 20.0-0.33 0.28-11.76 12.68 17.Loma Prieta (P0781) 25.8-0.45 0.24-5.28 3.43 18.San Fernando (P0056) 21.3-0.43 0.20-11.59 15.36 19.Landers (P0864) 16.0-0.37 0.21-4.93 5.79 20.Northridge (P0936) 27.2 0.41 0.28-8.317 5.35 Under the input matched ground excitations, maximum compressive stress occurring at the upper bases was doubly increased. The maximum was about 0.47 MPa (See Table 2). However, the increased compressive stress is still lower than the masonry compressive strength of 2.68 MPa. For tensile stress, the lateral inertia force not only increases the tension hoop stress at the bottom part of the inverted bell shaped body but also the tension in vertical direction at the middle of the top spherical cone part. The maximum vertical tensile stress due to the earthquake excitations was about 0.34 MPa which is higher than the tensile strength of 0.27 MPa. The analytical results indicated cracking in the area and confirmed the past failure mode at the top spherical cone, as seen in Fig. 1. The general state of the stresses is shown in Fig. 4. Max Compression Maximum Tension Fig. 4. General stresses distribution under the seismic loading; (a) Compression (b) Tension

Chayanon Hansapinyo / APCBEE Procedia 9 (2014 ) 217 221 221 For the deformation and acceleration, the building moved a little below the inverted bell part. It was about 0.3 mm. at the top of the inverted bell part (at the level of 15 m. from the base). However, ignoring the Manytiered umbrella, at the tip of the top spherical cone, the maximum displacement was about 30.1 mm (see Table 2). The accelerations at the point were also amplified. 4. Conclusion This paper presents a continue work from the accompanied paper name Ambient Vibration Tests and Finite Element Analysis for Dynamic Properties of Brick Masonry Inverted Bell-Shaped Chedi which aims to perform seismic evaluation of an esteemed brick masonry inverted bell-shaped chedi at Phrathat Doi Suthep temple, Chiangmai, Thailand, by using the finite element analysis. The validated finite element model from the accompanied paper was used. First, twenty past earthquake records were selected and matching of the records to the seismic response spectrum was made for equating the local seismic conditions. Then, the matched seismic waves were used for the input of time history analyses. The building performed very well under gravity loading in terms of both stresses limitation and deformations. However, under seismic loading, the top of the pagoda was very sensitive to the seismic waves. It was deformed significantly; accelerations were amplified and material was damaged by over-tensioning. Acknowledgements The author would like to thank the Commission on Higher Education, Thailand under the Nation Research University Project and Faculty of Engineering, Chiang Mai University for funding support. He is also grateful to Professor Matsushima, Kagawa University for the finite element analysis support. References [1] Dumrigul, S. Lanna reign. Ancient city. 1996. (in Thai) [2] ANSYS User s Manual Vol. I. Swanson Analysis Systems, Inc. 1994. [3] Lukkunaprasit, P., and Kuhatasanadeekul, N. Seismic zoning and seismic coefficients for Thailand. 1993 Annual Conference, Engineering Institute of Thailand. 1993: 268-287. (in Thai) [4] Warnitchai, P., and Lisantono, A. Probabilistic seismic risk mapping for Thailand. 11th World Conference on Earthquake Engineering. Acapulco, Mexico. 1996. [5] Petersen, M., Harmsen, S., Mueller, C., Haller, K., Dewey, J., Luco, N., Crone A., Lidke, D. and Rukstales, K. Documentation for the Southeast Asia Seismic Hazard Maps. U.S. Geological Survey. 2007. [6] Department of Public Works and Town & Country Planning-DPT. 1302-Design Standard for Earthquake Resistant Buildings, Bangkok, Thailand. 2009. (in Thai)