Design, Testing and Utilization of Welded-Wire Rack Decking

Similar documents
MBG HEAVY DUTY METAL BAR GRATING MANUAL. MBG Metal Bar Grating Division of THE NATIONAL ASSOCIATION OF ARCHITECTURAL METAL MANUFACTURERS

70 & 74. CMAA is an affiliate of the Material Handling Industry of America division of Material Handing Industry. Prepared by

Specifications for Top Running & Under Running Single Girder Electric Traveling Cranes Utilizing Under Running Trolley Hoist

For Electrical Intermediate Metal Conduit (EIMC)

Standards for Testing and Rating Shoring Equipment

Shelving PRODUCT CATALOG

SECTION PRE-ENGINEERED COLD-FORMED METAL ROOF AND FLOOR TRUSSES

MASTER GUIDE SPECIFICATION

April 2013 Vehicle Restraints 101

TCC/SHORE TRANSIT BUS MAINTENANCE FACILITY - PHASE II

American National Standard. Basic Hardboard

Dura Rack Family Of Products. 237,000 sq. ft. manufacturing facility

SECTION ALTERNATING TREAD STEEL STAIRS

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

SECTION ORCHESTRA PIT FILLER

80/90/100/120/mm POST Standard Medium Heavy Extra Heavy

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION (formerly 05425) PRE-ENGINEERED, PRE-FABRICATED COLD-FORMED STEEL ROOF & FLOOR TRUSSES

Bi-Directional Static Load Testing of Drilled Shafts

Bi-Directional Static Load Testing of Drilled Shafts

American Society of Agricultural and Biological Engineers

DEXION RACKING. The Product picture Effect of picture. 80/90/100/120/mm POST. Standard Medium Heavy Extra Heavy

GALVA-DECK Wire Mesh Decking

GALVA-DECK Wire Mesh Decking

SKATEWHEEL FLOW RACK

Installation and Use Instructions for the Big Ass Workbench Manufactured by Mercer Innovation, LLC

SK2000 Boltless Pallet Rack Installation and Assembly Manual

Upright Frame Selection Guide K-1000 is today s best teardrop pallet rack value. NOTES: K-1000 Selective Upright Capacity (pounds)

ANSI/ICEA T (2014)

Specifying Pre-Engineered CFS Floor and Roof Trusses 551f-98

Multi-Institutional Academic Health Science & Research Center Evansville, IN

AMERICAN NATIONAL STANDARD STANDARD. Maximum Bearing Bar Depth /2" (63.5 mm)

TEST METHOD FOR THERMAL TRANSMITTANCE AND AIR INFILTRATION OF GARAGE DOORS

1.02 SYSTEM DESCRIPTION

SECTION HANGERS AND SUPPORTS FOR PLUMBING

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

NTPEP. Mill: Name: Physical Address: Mailing Address: SAME AS ABOVE (if different from above) Primary Contact Name: Title: Telephone: Cell:

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

Copyright Notice. HCL Technologies Ltd. All rights reserved. A DEFINITIVE GUIDE TO DESIGN FOR MANUFACTURING SUCCESS

WALL CANTILEVER WORK STATION JIB CRANE

KENYA STANDARD KS 574:2017. Steel fabric for reinforcement of concrete Specification

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

UNIFIED FACILITIES GUIDE SPECIFICATIONS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SAMPLE SPECIFICATION ONLY FOR INFORMATIONAL PURPOSES NOT INTENDED FOR DUPLICATION OR USE SECTION XX.XX WELDED WIRE REINFORCEMENT

A. Section Metal Decking. (05300 in MF95) B. Section Cold Formed Metal Framing. (05400 in MF95)

SHORING & UNDERPINNING 02250

SECTION CHAIN LINK FENCES AND GATES (GALVANIZED) A. Fence framework, fabric, gates, and accessories.

Metal Framing Engineering Data & Specifications

A-Series Aluminum Gantry Crane

Standard Specification for Steel Welded Wire Fabric, Plain, for Concrete Reinforcement 1

Home Depot Page 1 of 5 HDPB Humacao, PR 10/19/09

1.02 SYSTEM DESCRIPTION

YOUR LITE-DECK SECTIONS

SECTION HANGERS AND SUPPORTS FOR ELECTRICAL SYSTEMS

UNIFIED FACILITIES GUIDE SPECIFICATIONS

SECTION 2831 ITEM F-162 CHAIN-LINK FENCES

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS, EVALUATION SERVICES EVALUATION CRITERIA FOR STEEL ROOF DECK.

CURTAINWALL DEFLECTION SOLUTIONS

SECTION ORNAMENTAL WELDED STEEL FENCING

Distriubted by Material Storage Systems, Inc CANTILEVER. Distriubted by Material Storage Systems, Inc

SECTION FABRICATED ENGINEERED STRUCTURES. A. Pre-engineered, shop-fabricated structural steel building with formed purlin framing.

AWS A5.35/A5.35M: 2015-AMD1 An American National Standard. Specification for Covered Electrodes for Underwater Wet Shielded Metal Arc Welding

" RISKS ASSOCIATED WITH THE INSTALLATION OF THE SYSTEM

Insulating Cellular Concrete Steel Joists Painting. A. America Society for Testing and Materials (ASTM):

STORAGE RACKS PLAN REVIEW LIST (2011 LABC)

Division MEDICAL EQUIPMENT SUPPORT SYSTEMS PART 1 GENERAL

Superior Aluminum Guide Specification 10/4/2016 Non-Welded Aluminum Pipe Railing

600 SERIES FOUNDATIONLESS JIB CRANE MANUAL ADDENDUM

SECTION COMPOSITE METAL DECKING

SECTION REINFORCING STEEL

The Edge Protection Federation Containment Systems Product Specification, Test Methods

Section REINFORCING STEEL

AWS D1.4/D1.4M:2018 An American National Standard. Structural Welding Code Steel Reinforcing Bars

SAMPLE SPECIFICATION ONLY FOR INFORMATIONAL PURPOSES NOT INTENDED FOR DUPLICATION OR USE SECTION XX.XX WELDED WIRE REINFORCEMENT

HOT ROLLED STEEL FLAT PRODUCTS FOR STRUCTURAL FORMING AND FLANGING PURPOSES SPECIFICATION (Third Revision of IS 5986)

USER'S GUIDE FOR INSPECTION OF DAMAGED STORAGE RACK SYSTEMS DON T WAIT UNTIL IT S TOO LATE!

SECTION COLD-FORMED METAL FRAMING

Stainless Steel Pipe ASME B36.19M (Revision of ANSI/ASME B36.19M-1985) AN AMERICAN NATIONAL STANDARD

SAMPLE GUIDE SPECIFICATIONS FOR OSTERBERG CELL LOAD TESTING OF DRILLED SHAFTS

SECTION METAL STAIRS

2 PALLET P RA ALLET CKING RA

Nafadi, Khalaf Alla, Lucier, Rizkalla, Zia and Klein BEHAVIOR AND DESIGN OF DIRECTLY LOADED LEDGES OF SHORT SPAN L- SHAPED BEAMS

Safety Documents > Safety Manual > Scaffolds

Safety in a Second Guardrail Testing

Linings of Aboveground Petroleum Storage Tank Bottoms API RECOMMENDED PRACTICE 652 FOURTH EDITION, SEPTEMBER 2014

UDL. up to QUICK. boltless. Expo Shelving. Adaptable Boltless System

USER'S GUIDE FOR INSPECTION OF DAMAGED STORAGE RACK SYSTEMS DON T WAIT UNTIL IT S TOO LATE!

SECTION STRUCTURAL STEEL FRAMING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

Perspectives on Material Handling Practice

SK3000 Structural Channel Bolted Pallet Rack: Model Number System

ITEM 555 CHAIN LINK FENCING

ANSI C (R2002, R2012) Reaffirmation of ANSI C (R2002) American National Standard. Thermal Demand Meters

BEARING METAL STUD FRAMING

SECTION DECORATIVE METAL FENCES AND GATES

AWS A5.28/A5.28M:2005 An American National Standard. Specification for Low-Alloy Steel Electrodes and Rods for Gas Shielded Arc Welding

SECTION MECHANICALLY STABILIZED EARTH 1.01 SUMMARY

Transcription:

MH 26.2-2007 (revision of MH26.2 2004) Design, Testing and Utilization of Welded-Wire Rack Decking Material Handling Industry of America A Division of Material Handling Industry 8720 Red Oak Blvd., Suite 201 Charlotte, NC 28217-3992 standards@mhia.org 2007 by Material Handling Industry All rights reserved.

American National Standard Approval of an American National Standard requires verification by ANSI that the requirements for due process, consensus, and other criteria for approval have been met by the standards developer. Consensus is established when, in the judgment of the ANSI Board of Standards Review, substantial agreement has been reached by directly and materially affected interests. Substantial agreement means much more than a simple majority, but not necessarily unanimity. Consensus requires that all views and objections be considered, and that a concerted effort be made toward their resolution. The use of American National Standards is completely voluntary; their existence does not in any respect preclude anyone, whether he has approved the standards or not, from manufacturing, marketing, purchasing, or using products, processes or procedures not conforming to the standards. The American National Standards Institute does not develop standards and will in no circumstances give an interpretation of any American National Standard. Moreover, no person shall have the right or authority to issue an interpretation of an American National Standard in the name of the American National Standards Institute. Requests for interpretations should be addressed to the sponsor whose name appears on the title page of this standard. CAUTION NOTICE: This American National Standard may be revised or withdrawn at any time. The procedures of the American National Standards Institute require that action be taken periodically to reaffirm, revise or withdraw this standard. Purchasers of American National Standards may receive current information on all standards by calling or writing the American National Standards Institute. Published by Rack Manufacturers Institute An Affiliated Trade Association of Material Handling Industry of America, a division of Material Handling Industry 8720 Red Oak Blvd., Suite 201, Charlotte, NC, 28217-3992 Telephone: (704) 676-1190 Fax: (704) 676-1199 www.mhia.org/rmi standards@mhia.org 2007 by Material Handling Industry All rights reserved. No part of this publication may be reproduced in any form, in an electronic retrieval system or otherwise, without prior written permission of the publisher. Printed in the United States of America. ii

ANSI MH26.2 2007 (revision of MH26.2 2004) American National Standard Design, Testing and Utilization of Welded-Wire Rack Decking Rack Manufacturers Institute An Affiliated Trade Association of Material Handling Industry of America, A Division of Material Handling Industry Approved 15 November 2007 American National Standards Institute, Inc. iii

Disclaimer This standard, which was developed under the Canvass method of Material Handling Industry and approved by ANSI on 15 November 2007, represents suggested design practices and performance testing criteria for welded-wire rack decking. It was developed with the sole intent of offering information to parties engaged in the manufacture, marketing, purchase, or use of welded-wire rack decking. This standard is advisory only and acceptance is voluntary and the standard should be regarded as a guide that the user may or may not choose to adopt, modify, or reject. The information does not constitute a comprehensive safety program and should not be relied upon as such. Such a program should be developed and an independent safety adviser consulted to do so. Material Handling Industry (MHI) and its members assume no responsibility and disclaim all liability of any kind, however arising, as a result of acceptance or use or alleged use of this standard. User specifically understands and agrees that MHI and their officers, agents, and employees shall not be liable under any legal theory of any kind for any action or failure to act with respect to the design, erection, installation, manufacture, preparation for sale, sale, characteristics, features, or delivery of anything covered by this standard. Any use of this information must be determined by the user to be in accordance with applicable federal, state, and local laws and regulations. MHI makes no warranties of any kind, express, implied, or statutory, in connection with the information in this standard. MHI specifically disclaims all implied warranties of merchantability or of fitness for particular purpose. By referring to or otherwise employing this standard, the user agrees to defend, protect, indemnify, and hold MHI and their officers, agents, and employees harmless from and against all claims, losses, expenses, damages, and liabilities, direct, incidental, or consequential, arising from acceptance or use or alleged use of this standard, including loss of profits and reasonable attorneys' fees which may arise out of the acceptance or use or alleged use of this standard. The intent of this provision and of the user is to absolve and protect MHI and their officers, agents, and employees from any and all loss relating in any way to this standard, including those resulting from the user's own negligence. iv

Foreword (This foreword is not part of American National Standard MH26.2-2007) Development of this Standard was undertaken by a technical working group of the Rack Manufacturers Institute (RMI). This document replaces an earlier edition designated American National Standard MH26.2-2004. This standard was originally developed in 1997 by the Industrial Metal Containers and Wire Decking (IMC&WD) Product Section of Material Handling Industry of America (MHIA). Upon admitting wire deck manufacturers into its membership, the Rack Manufacturers Institute assumed responsibility for maintenance and further development of the document. The Welded Wire Decking Technical Group is a working group of the Rack Manufacturers Institute (RMI), an affiliated trade association of Material Handling Industry of America (MHIA). The Welded-Wire Decking Technical Group is comprised of a substantial portion of the major companies that design and manufacture welded-wire rack decking in the United States. This standard is the result of the group s recognition of the need to develop a comprehensive safety standard and establish minimum design and performance criteria to ensure the safe application and utilization of welded-wire rack decking, and was formulated under MHIA procedures approved by the American National Standards Institute (ANSI). At the date of approval of this standard, the Welded Wire Decking Technical Work Group of RMI consisted of the following member companies: American Wire Products Atlas Material Handling, Inc. Cargotainer ITC J&L Wire Products Nashville Wire Products Manufacturing Co., Inc. Wireway Husky Corporation Suggestions for improvement, and questions regarding interpretation, of this standard will be welcome. They should be sent to: MH26.2 Working Group (RMI), Material Handling Industry of America, 8720 Red Oak Blvd., Suite 201, Charlotte, NC, 28217-3992; standards@mhia.org. v

AMERICAN NATIONAL STANDARD ANSI MH26.2 2007 (revision of MH26.2 2004) Design, Testing and Utilization of Welded-Wire Rack Decking Table of Contents Page 1 Scope and Objectives.....1 2 Normative References.....1-2 3 Definitions.....2-3 3.1 General.....2-3 3.2 Dimensions.....3 3.3 Safety Factor.....3 4 Materials.....4 5 Dimensional Characteristics.....4-7 5.1 Nominal Dimensions.....4 5.2 Actual Dimensions.....4 5.3 Manufacturing Tolerances.....4-7 6 Design & Fabrication Procedures.....8 6.1 Design Procedures.....8 6.2 Fabrication Procedures.....8 7 Test Procedures.....8-10 7.1 Line Load Test.....8-10 List of Figures Figure 1: Steel Storage Rack System.....5 Figure 2: Step Beam.....6 Figure 3: Box Beam.....6 Figure 4: Deck Section.....7 Figure 5: Decking Section with Reinforcement.....7 Figure 6: Two Line-Load Testing Diagram.....10 vi

1 SCOPE AND OBJECTIVES Design, Testing and Utilization of Welded-Wire Rack Decking This standard is established to provide a guideline for design, testing, fabrication and utilization of welded-wire mesh rack decking utilized as an accessory for industrial steel storage racks. This standard applies to uniformly loaded rack decking fabricated from welded-wire mesh, with permanently attached reinforcements, for use in storage racks. The purpose for such rack decking is to provide storage capability by creating a surface, in conjunction with a superstructure or framework hereinafter referred to as rack, upon which to place materials that may be on pallets, in containers, or in some other form. This standard does not apply to: Rack decking manufactured prior to publication date of this standard Rack decking that has been improperly installed, altered, damaged, or used in any manner other than that for which it was originally intended, designed, purchased, sold, or a combination thereof Decking or shelf surface materials other than welded-wire rack decking 2 NORMATIVE REFERENCES The following standards contain provisions, which through reference in this text, constitute provisions of this American National Standard. At the time of publication of this document, the editions indicated were valid. All standards are subject to revision, and parties to agreements based on this American National Standard are encouraged to investigate the possibility of applying the most recent editions of the standards indicated below. [1] ANSI/AWS D1.1/D1.1M 2002, Structural Welding Code Steel [2] AWS C1.1M/C1.1 2000, Recommended Practices for Resistance Welding [3] AISC, ASD Manual of Steel Construction, 9th edition [4] AISI Publication SG 671, 1991 (1986 edition with 1989 Addendum), Specification for The Design of Cold-Formed Steel Structural Member, Allowable Stress Design [5] AISI Publication SG 672, Test Procedures for Use with August 19, 1986 Edition of the Cold-Formed Specification [6] ASTM A510-03, Standard Specification for General Requirements for Wire Rods and Coarse Round Wire, Carbon Steel [7] ASTM A82-ae1-1997, Specifications for Cold-Dawn Steel Wire for Concrete Reinforcements [8] ASTM A 1011/A 1011M 01a, Standard Specification for Steel, Sheet and Strip, Hot- Rolled, Carbon, Structural, High Strength Low-Allow and High-Strength Low-Allow with Improved Formability 1

[9] ASTM A 1008/A 1008M 01a, Standard Specification for Steel, Sheet, Cold-Rolled, Carbon, Structural, High-Strength Low-Alloy and High-Strength Low-Allow with Improved Formability 3 DEFINITIONS 3.1 General 3.1.1 Beam A horizontal load-carrying member of the steel storage rack system (See Figure 1, Items A and B). 3.1.2 Capacity A maximum recommended uniformly distributed static load independent of the support system. 3.1.3 Decking section A completely fabricated decking assembly with reinforcing members ready for installation upon supporting storage rack framing (See Figures 4 and 5). One or more decking sections are used to form a shelf surface. 3.1.4 Nonstep beam - A beam that offers only one horizontal surface on which the rack decking can be placed. Examples of nonstep beams are "Box" sections, tubing, channels and I-beams (See Figure 1, Item B and Figure 3). 3.1.5 Nonstep beam application An application in which the area of wire decking support is confined to the surface area on the top of the front and rear beams. 3.1.6 Rack The support system for rack decking, specifically the upright-frames and beams in their assembled configuration (See Figure 1). 3.1.7 Rack Decking (rack deck) Same as decking section in 3.1.3 (See Figures 4 and 5). 3.1.8 Rack opening The distance between a pair of upright frames which is measured parallel with the horizontal rack beam (See Figures 1, 2 and 3). 3.1.9 Reinforcement member The component of rack decking which increases the capacity rating and rigidity of the assembly. Examples are channels, tubes, rods, etc. (See Figure 5, Item E). 3.1.10 Shelf depth (O.D.) The horizontal distance measured between the outside faces of beams in their assembled configuration (See Figure 1, Item C). 3.1.11 Step beam A beam that provides two horizontal surfaces on which the rack decking can be placed. Usually the top surface of the beam supports the wire mesh and the notched lower surface of the beam supports the reinforcing members (See Figure 1, Item A and Figure 2). 3.1.12 Uniformly distributed load (UDL) Any static load which is evenly distributed over the entire surface on the rack deck independent of the support system. 2

3.1.13 Waterfall Descriptive term for the portion of the wire mesh utilized on some wire decks that runs perpendicular to the load bearing surface. Most commonly the waterfall extends downward over the outside face of the beam (See Figure 4, Item A). In this case, the waterfall should extend past the radius of the beam a sufficient distance to minimize the potential for accidental displacement of the decking. 3.2 Dimensions 3.2.1 Depth The overall depth of the wire deck (See Figure 4, Item D) 3.2.2 Width The overall width of the wire deck (See Figure 4, Item W) 3.2.3 Wire mesh spacing The nominal center-to-center spacing of the wire mesh configuration. Typically described as front-to-back wire spacing followed by left-to-right wire spacing. Please note this is not the distance between the wires or the dimension of the opening itself but rather the distance from the center of one wire to the center of the next parallel wire. (See Figure 4, Items X and Y) 3.2.4 Inside Dimension (ID) See Figures 1, 2 and 3. 3.2.5 Bottom (ID) See Figures 2 and 3. 3.2.6 Step Height The vertical distance between the two upper horizontal surfaces of a step beam (See Figures 1 and 2, Item C). 3.2.7 Step Depth The distance between the two inside vertical surfaces of a step beam (See Figures 2, Item E). 3.2.8 Height of Waterfall Distance measured from the load bearing surface of the deck to the end of the bent perpendicular wire. Typically this dimension is approximately 1.5 inches (38.1mm). (See Figure 4, Item A) 3.2.9 Top Width of Beam See Figures 1 & 2, Item A 3.3 Safety Factor The ratio of the failure load to the rated load carrying capacity of the component. Normally the rated load carrying capacity is referred to as the capacity rating. Refer to Section 7.1.3 for allowable load capacity ratings. 3

4 MATERIALS This Specification assumes the use of steel of structural quality as defined in general by the specifications of the American Society for Testing and Materials (ASTM) that are listed in the American Iron and Steel Institute (AISI) North American Specification for the Design of Cold- Formed Steel Structural Members [4] 1, and the American Institute of Steel Construction (AISC) Specification for Structural Steel Buildings [3]. Steels not listed in the above specifications are not excluded provided they conform to the chemical and mechanical requirements of either reference [4] or [3], or other published specifications which establish their properties and structural suitability, and provided they are subjected either by the producer or the purchaser to analyses, tests, and other controls in the manner prescribed by either reference [4] or [3] as applicable. 5 DIMENSIONAL CHARACTERISTICS 5.1 Nominal Dimensions The nominal dimensions of welded wire rack decking shall be described by... 5.1.1 Specifying the front-to-back dimension followed by the left-to-right dimension. 5.1.2 Describing the mesh by specifying the center-to-center dimension of the front-to-back wires (See Figure 4, Item X), followed by the center-to-center dimension of the left-to-right wires (Figure 4, Item Y), followed by the gauge of the wire or the diameter of the wire expressed in decimal inches to the nearest.001 inch. 5.1.3 Specifying the quality and description of supports attached to the decking section. 5.1.4 Specifying the uniformly distributed load capacity of the decking section. 5.2 Actual Dimensions The actual dimensions of the welded-wire rack decking sections represent the manufacturing dimensions which shall take into account necessary clearances required to fit the specific rack being used. 5.3 Manufacturing Tolerances The allowable tolerances from actual manufacturing dimensions shall be specified in the following paragraphs. 5.3.1 The front-to-back dimensions of the finished welded-wire rack decking sections shall be the actual dimension plus or minus 1/8 inch (3.2 mm). 5.3.2 The left-to-right dimension of the finished welded-wire rack decking sections shall be the actual dimension as measured from out to out or centerline of end wires plus or minus 1/4 inch (6.3 mm). 1 Numbers in brackets refer to corresponding numbers in Section 2, Normative References. 4

5.3.3 The diagonal measurements (squareness) shall be within 1/2 inch (12.7 mm) or 1%, whichever is greater. 5.3.4 The length of reinforcing members shall be within plus or minus 1/16 inch (1.5 mm). The camber and sweep of reinforcing members shall be no greater than 1/2 of 1% of their lengths with a maximum of 1/4 inch (6.3 mm). 5.3.5 Center-to-center distances between wires on mesh panels shall be within plus or minus 1/8 inch (3.2 mm), non-cumulative, or the specified wire mesh spacing. Figure 1. Steel Storage Rack System 5

Figure 2. Step Beam Figure 3. Box Beam 6

Figure 4. Deck Section Note: Wire mesh shown without reinforcements for clarity only. Refer to Section 3.2 Dimensions Figure 5. Decking Section with Reinforcement 7

6 DESIGN & FABRICATION PROCEDURES 6.1 Design Procedures 6.1.1 Design shall be based upon determination of capacity and allowable deflections. Designs shall be based upon uniformly distributed static loading. The determination of safe load-carrying capacity and allowable deflections shall be carried out in accordance with generally accepted engineering practices, and as specified in AISI SG 671, ASIS SG 672, or AISC M016. However, where the composition or configuration of elements, assemblies, or details of cold-formed or hot-rolled structural members is such that calculation of their safe load-carrying or deflection cannot be made in accordance with the above listed specifications, their safe structural performance shall be established through a testing program as specified in Section 7. Note that test results must be based upon tested yield as compared or in proportion to the material specification s allowable minimum yield. 6.1.2 While welded-wire rack decking is generally designed for static uniformly distributed loads, manufacturers may be able to provide designs suitable for static non-udl loads upon special request. Welded-wire rack decking may not be suitable for dynamic loading. 6.2 Fabrication Procedures 6.2.1 All welding shall be performed in a manner consistent with AWS C1.1 [2], for resistance welding and ANSI/AWS D1.1 [1], for arc welding. 6.2.2 The wires shall be assembled by means that will ensure accurate spacing and alignment of all members of the finished wire mesh. The crosswire members shall be welded at each intersection. 6.2.3 The reinforcing members of rack decking shall be assembled by means that will ensure accurate spacing and alignment of all members of the finished rack deck. The reinforcing members shall be welded at each intersection with the cross wire members. 7 TEST PROCEDURES 7.1 Line Load Test 7.1.1 Equipment Required An apparatus capable of applying two-line loads to a decking surface at the 1st and 3rd quarter points (Figure 6). The line loads shall be 2 inches (50.8 mm) wide steel bars or tubes and no less than 2 inches (50.8 mm) greater in length than the width of the rack decking assembly to be tested. The bars or tubes shall be affixed to a steel platen in such a manner as to prevent flexing or deforming greater than 1/100 inch (0.25 mm) under the heaviest load applied. The apparatus must be designed in such a way that at no time during the test does anything 8

other than the 2 inch (50.8 mm) surface of the bar or tube come into contact with the rack decking assembly. The apparatus must be 400 lbs. (181.8 kg) or less in weight. A support system within which to place the rack decking assembly shall be designed to duplicate the support provided by a steel storage rack system. This support system may duplicate any beam configuration (rollformed step beams, roll-formed box beams, structural beams, etc.) but may not flex or deform more than 1/100 inch (0.25 mm) under the heaviest load applied. Any convenient means of applying a variable and controllable static load to the apparatus described above. Any convenient means of measuring deflection in 1/100-inch (0.25 mm) readings. 7.1.2 Procedure The following test procedure is designed to apply a line load at each of two quadrants, (specifically. the 1st and 3rd) of the wire decking assembly by running parallel to the rack beams. The load applied at the quadrants is equal to the uniformly distributed load (UDL). Example: 2000 lbs. (907.2 kg) applied using two-line loads at the first and third quadrants of the deck is equal to 2000 lbs. (907.2 kg) uniformly distributed load. 1) Place the rack decking assembly on a rigid, level support system that supports the rack decking at its extended locations. The support system should support the rack decking assembly in a manner identical to that of the beams of a steel storage rack system. 2) Position deflection-measuring devices on both: The reinforcing member nearest the geometric center, at the point midway between the rack beams. The reinforcing member nearest either side at the point midway between the rack beams. If the rack decking assembly has only two reinforcing members, then position the deflection measuring devices on either side of the two reinforcing members, at a point midway between the rack beams. 3) Position the apparatus onto the decking so that the 2 inch wide (50.8 mm) bars or tubes contact the surface of the rack decking assembly to be tested and run parallel to the rack beams so as to create 2-line loads at the first and third quadrants (Figure 6) of the rack decking. 4) Apply an initial line load of 10% of the desired test capacity or the actual weight of the testing apparatus, whichever is greater, to ensure the rack decking assembly has been properly seated into the support system to begin recording deflections. 9

5) Increase the Load applied up to the point at which deflection of D/165 is achieved in a minimum of four increments. Record the capacity exerted as W1. (Refer to Figure 4 whereas D is defined as the overall depth of the deck). 6) Increase the Load applied to Structural Collapse in a minimum of no less than four increments. Record the capacity exerted when structural collapse occurs. Define W2 by dividing the recorded load by two (2). Structural collapse is defined as the point at which the support channels continue to deflect without any additional load being applied. 7.1.3 Allowable Load Capacity Ratings Capacity shall be defined as the lesser of the two values W1 and W2. Figure 6: Two Line Load Testing Diagram 10