SCUtils Monitoring APC UPS Guide Solution for Microsoft System Center 2012 R2/2016 Operations Manager

Similar documents
SCUtils WorkItem Scheduler Guide Solution for Microsoft System Center 2012 Service Manager

Using UPSMON-PRO Monitoring Software. Opening UPSMON-PRO Monitoring Software

Galaxy 300 and Galaxy 300i

Business Communications Manager UPS Installation and Configuration Guide

SCUtils SLAInstanceDur ation Guide Solution for Microsoft System Center 2016 Service Manager

Smart-UPS Lithium-ion Short-depth UPS 120V. APC Certainty with Total Cost of Ownership in mind

Galaxy 300. Operation 05/

Enterprise Vault Whitepaper

Smart-UPS Lithium-ion Short-depth UPS 120V. APC Certainty with Total Cost of Ownership in mind

Agilent Infinity LC Instrument Component Software Version 1.0 for Empower Software

Table of contents. 1. Introduction

Web TimeSheet Integration Manager for Microsoft Project Server. Version 2.6 USER GUIDE

Business Communications Manager UPS Installation and Configuration Guide

HOBO Plug Load Logger (UX ) Manual

HP0-S25. Implementing ProLiant ML DL SL Servers.

Maximize the performance of your Siemens air-cooled drives

What s New in Global Storage Manager 4.0?

itemp Anywhere Wireless Sensors and Cellular Gateway User s Guide

Agile Product Lifecycle Management

Visual BI Extensions for SAP BusinessObjects Design Studio (VBX) - Installation Guide -

Visual BI Extensions for SAP BusinessObjects Design Studio (VBX) - Installation Guide -

EPS 7000 and EPS 8000

Acceleration Systems LLC

MGE Galaxy /50/60/80/100/130 kva. The recommended power protection for all critical applications

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kw. User Manual.

User s Guide. LX Platform Devices

MGE TM Galaxy TM 6000: Specification guide

Developing and Deploying vsphere Solutions, vservices, and ESX Agents

Course 55004A: Installing and Configuring System Center 2012 Operations Manager

MGE Galaxy /30/40/60/80/100/120 kva. The recommended power protection for all critical applications

APC by Schneider Electric MGE GALAXY 5500 Uninterruptible Power Supply Guide Specifications 20 kva to 120 kva Parallel UPS, three-phase

bprobe Installation and Configuration Guide

Sage What s New. December 2017

Deltek Touch for Maconomy. Touch 2.2 User Guide

Design, Install and Manage System Center 2012 Operations Manager

Sage HRMS 2014 Sage Employee Self Service. Installation and Setup Guide. October has been retired. This version of the software

APC by Schneider Electric MGE GALAXY 9000 Uninterruptible Power Supply Guide Specifications 800/900 kva to 4800/5400 kva Parallel UPS, three-phase

Oracle Enterprise Manager

ETL for Data Center Operation Administration Guide 7EN /2016

2005/01. GV-Data Capture

Sage HRMS 2014 Sage Employee Self Service Installation and Setup Guide. October 2013

APC by Schneider Electric MGE GALAXY 7000 Uninterruptible Power Supply Guide Specifications 160 kva to 500 kva Single UPS 3-phase system

MPM 100 Monitor Product Description Guide

Solar Eye User Manual

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Multi-door Networking Controller

Agilent Quality Tool Online Help. Printable Version. Intelligent Test Software Solutions. ITFSS p January 2005

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

INDEX. 1 Introduction. 2 Software installation. 3 Open the program. 4 General parameters. 5 Tuning

DPS. Save This Manual

IMonitorEAM Installation Manual

Administrator Quick Reference Virtual TimeClock 15 Network Edition

OWNER'S OPERATING MANUAL

Controlling the Agilent 1260 Infinity/1290 Infinity II Multisampler (G7167A/B) in Waters Empower 3 Environment

Web TimeSheet Integration Manager for Microsoft Project Standard/Professional. Version 4.2 USER GUIDE

NetSuite OpenAir Mobile for iphone User Guide Version 2.2

APC Smart-UPS VT, w/parallel Operation Guide Specification for 10kVA to 40kVA 3 400/ V Solutions Uninterrupted Power Supply

Sage 100. Sage Payroll Services Getting Started Guide

Integrated Service Management

RUGGEDCOM NMS v1.6. Preface. Welcome to NMS 1. Installation 2. Notes on NMS 3. Installation Upgrades 4. Installation Guide.

First Data Merchant Solutions EFTPOS. 8006L2-3CR Integrated PIN Pad. User Guide

Advanced network device management. you can

Remedy Change Management 4.0

SECTION [ ] [16611] SOLID STATE UNINTERRUPTIBLE POWER SUPPLY

Winzer Corporation 1 Revision: 4.0

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kva. User Manual.

GV-Data Capture V2 User's Manual

U g CS for DJI Phantom 2 Vision+, Phantom 3 and Inspire 1 Mobile companion application

Mobile for iphone User Guide

Mobile for Android User Guide

DATA LOGGER Model DL-SA11

Oracle Talent Management Cloud. What s New in Release 9

Invoices 3.3 User Guide

SECTION [ ] [16611] SOLID STATE UNINTERRUPTIBLE POWER SUPPLY

EMPLOYEE TRAINING MANAGER GETTING STARTED. January 2018

Configuring Power over Ethernet

SAP Management Pack for Microsoft System Center Operations Manager

Desktop Activity Intelligence

Printed Documentation

GSX Monitor & Analyzer. for BlackBerry Enterprise Server 12

Smart-UPS VT kVA 400V. Operation Manual

Agile Product Lifecycle Management

Oracle Argus Mart. Administrator s Guide Release 1.0 E

HOW INTEGRATION WORKS...

Liebert NXL 1100kVA / 1100kW UPS Maximum UPS Protection for Large Data Centers

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

Sage What s New. March 2018

Programmable Device Server User Manual

Project Server 2013 Inside Out

USER MANUAL. Inventory Manager TABLE OF CONTENTS. Version: 3.0. Compatibility:

Perfect Service. Testing: Landesk Service Desk 7.6. Dr. Götz Güttich

BillQuick MYOB Integration

Enterprise Inventory and Service-Level Optimization Analytics

Replacing the Billboard UPS

CMS Server V6 Installation User Manual Edition: EN

RT5kVA and RT6kVA 3U Rack or Tower Uninterruptible Power Supplies Product Guide

Delta UPS - Ultron Family. HPH Series, Three Phase 60/80/100/120 kva. User Manual. The power behind competitiveness EPO

Opera 3 Stocktake. Accreditation Training Courseware

V1.0(2016) IP KEYBOARD CONTROLLER

Transmission Initial Fill Machines ICT Requirements

Transcription:

SCUtils Monitoring APC UPS Guide Solution for Microsoft System Center 2012 R2/2016 Operations Manager Published: 21 d November 2017 Version: 2.0 Authors: Yuriy Nizhnikov Feedback: support@scutils.com

Contents 1. Getting started... 3 2. Compatibility... 3 2.1. Feedback... 3 3. Requirements... 4 4. Installation... 4 5. Uninstallation... 4 6. Using SCUtils Monitoring APC UPS... 4 6.1. Discovery APC UPS devices... 4 6.2. Monitors... 5 6.3. Informative rules... 5 6.4. Using SNMP traps... 8 6.5. Reports... 9 7. Known issues and troubleshooting... 10 7.1. Errors and warning during a discovery process... 10 2

1. Getting started SCUtils Monitoring APC UPS is an extension for Microsoft System Center Operations Manager to monitor APC UPS devices. The product is based on the powernet417.mib MIB file. APC is a trademark of the Schneider Electric. All other trademarks are property of their respective owners. 2. Compatibility WARNING! Be aware that the version 2.0 is not compatible with 1.0-1.6 versions. Uninstall any pre- V2 version before importing the version 2.0 and subsequent SCUtils Monitoring APC UPS has been designed and tested for the following versions of Microsoft System Center 2012 R2/2016 Operations Manager: Microsoft System Center 2012 R2/2016 Operations Manager. The product might work with Microsoft System Center 2012 Operations Manager SP1, but it is not tested. If you intend to use SCUtils Monitoring APC UPS in pre-r2 environments, please carefully evaluate the product in the testing environment. 2.1. Feedback Our team is always on the way of the improvement of our solutions. We highly appreciate every feedback from our customers. Please send us your thoughts, complains, and feature requests at support@scutils.com. 3

3. Requirements All APC UPS devices must be discovered as network devises. Please refer to the Operations Manager guide to details. 4. Installation Download the archive SCUtils Monitoring APC UPS v2.0.zip from Downloads page of www.scutils.com. Copy SCUtils Monitoring APC UPS v2.0.zip to the Operations Manager management server. To install the management packs: 1. Log on to the computer that hosts the Operations Manager console using an account that administrative rights in the Operations Manager. 2. In the Operations Manager console, select Administration. 3. In the Administration pane, select Management Packs. 4. In the Tasks pane, under Actions, click Import Management Packs. 5. In the Select Management Packs box, click on Add button, select Add from disk, in the Online Catalog Connection dialog select No. 6. In the Select Management Packs to Import box, point to the location of SCUtils Monitoring APC UPS. 7. In the list of files, select the management packs SCUtils.APC.UPS.Dashboard.MP.xml and SCUtils.APC.UPS.MP.mpb, and then click Open. 8. In the window Import Management Packs, click Install. 5. Uninstallation To uninstall SCUtils Monitoring APC UPS log in the Operations Manager management server where the product was installed. Open Operations Manager 2012 console, go to Administration -> Management Packs. Select SCUtils APC UPS Dashboards, SCUtils APC UPS and click on Delete task. If required, delete all depending management packs as well. 6. Using SCUtils Monitoring APC UPS 6.1. Discovery APC UPS devices After the successful import management pack the discovery process will start. The default interval for discoveries is set to 14400 seconds. You can use override to specify shorter intervals to speed up the process. To change the scope in the Object Discoveries view in the Authoring Pane, please filter objects by APC UPS. 4

Fig. 1 Changing the scope in Object Discoveries 6.2. Monitors SCUtils Monitoring APC UPS uses monitors to control the state of APC UPS s components. All monitors are enabled by default. Please use overrides to disable any monitor if required. UPS Monitor UPS Battery Replacement Indicator UPS Battery Status UPS Output Load UPS Battery Capacity UPS Battery Runtime Remaining Battery Temperature UPS Number Of Bad Battery Packs UPS Basic Output Status 6.3. Informative rules The table below presents all informative rules of SCUtils Monitoring APC UPS. UPS Rule UPS Battery RunTime Remaining UPS Basic Battery Status UPS Time On Battery UPS Battery Temperature UPS Input Line Voltage UPS Input Frequency UPS Battery Capacity UPS Output Voltage 5

UPS Rule UPS Output Load UPS Output Frequency UPS Output Current Environment Humidity Environment temperature UPS SNMP Trap Rule SEVERE: Communication to the UPS has been lost SEVERE: The UPS has sensed a load greater than 100 percent of its rated capacity. SEVERE: The UPS failed its internal diagnostic self-test. SEVERE: The UPS batteries are discharged WARNING: The UPS has switched to battery backup power. WARNING: The UPS has enabled SmartBoost (TM). SEVERE: The UPS batteries are low and will soon be exhausted. INFORMATIONAL: Communication with the UPS has been established. INFORMATIONAL: Utility power has been restored. INFORMATIONAL: The UPS passed its internal self-test. INFORMATIONAL: The UPS has returned from a low battery condition. WARNING: The UPS has been turned 'off' by the management station. WARNING: The UPS is entering 'sleep' mode. Power to the load will be cut off. INFORMATIONAL: The UPS has returned from 'sleep' mode. WARNING: The UPS has started its reboot sequence. WARNING: The dip switch settings on the UPS have been changed, possibly altering UPS performance. SEVERE: The batteries of the UPS need immediate replacement. SEVERE: One of the contacts on the Environmental Monitor has changed from its default position. INFORMATIONAL: A fault on one of the Environmental Monitor contacts has been resolved. SEVERE: UPS on bypass due to internal fault WARNING: UPS on bypass - user set via software or panel WARNING: UPS on bypass - initiated by user INFORMATIONAL: UPS has returned from bypass SEVERE: Base module bypass power supply needs repair SEVERE: Base module fan needs repair SEVERE: Check installation of external battery packs signal cable INFORMATIONAL: UPS is communicating with the external battery packs. INFORMATIONAL: A battery calibration test has been initiated on the UPS. INFORMATIONAL: Agent restarting as commanded by manager. INFORMATIONAL: A UPS is turned on. WARNING: The UPS is reducing the line voltage via SmartTrim(TM). INFORMATIONAL: Authentication on agent code image is done. INFORMATIONAL: The overload condition has been cleared. INFORMATIONAL: The UPS has returned from SmartBoost(TM). INFORMATIONAL: The UPS has returned from SmartTrim(TM). INFORMATIONAL: A bad battery fault has been cleared. INFORMATIONAL: The UPS has finished calibrating. 6

UPS SNMP Trap Rule INFORMATIONAL: A UPS discharge condition has been cleared. INFORMATIONAL: A graceful shutdown has been initiated. WARNING: The output voltage is not within acceptable range. INFORMATIONAL: The output voltage has returned to an acceptable level. WARNING: The battery charger has failed. INFORMATIONAL: The battery charger failure condition has been cleared. WARNING: The battery temperature threshold has been violated. INFORMATIONAL: The battery over temperature has been cleared. WARNING: SmartBoost (TM) or SmartTrim (TM) relay fault. INFORMATIONAL: SmartBoost(TM) or SmartTrim(TM) relay fault has been cleared. SEVERE: Probe 1 humidity threshold violated. The first variable is the current humidity. INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 1. SEVERE: An Environmental Monitor temperature threshold has been violated on probe 1. INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 1. SEVERE: An Environmental Monitor humidity threshold has been violated on probe 2. INFORMATIONAL: An Environmental Monitor humidity threshold violation has been cleared on probe 2. SEVERE: An Environmental Monitor temperature threshold has been violated on probe 2. INFORMATIONAL: An Environmental Monitor temperature threshold violation has been cleared on probe 2. INFORMATIONAL: The specified Outlet Group turned on. WARNING: The specified Outlet Group turned off. WARNING: The internal over temperature condition exists. INFORMATIONAL: The internal over temperature condition cleared. INFORMATIONAL: The MPU has been reset. INFORMATIONAL: The Output Switch is closed. INFORMATIONAL: The Output Switch is open. INFORMATIONAL: A calibration value in the stack was changed. WARNING: The battery temperature sensor fault exists. INFORMATIONAL: The battery temperature sensor fault cleared. WARNING: A battery bus soft start fault exists. INFORMATIONAL: A battery bus soft start fault exists cleared. WARNING: A PFC fault exists. INFORMATIONAL: The PFC fault cleared. WARNING: The inverter fault exists. INFORMATIONAL: The inverter fault cleared. WARNING: The backfeed relay (or its driver) has a fault. WARNING: The backfeed relay (or its driver) has a fault cleared. WARNING: A bypass relay (or its driver) has a fault. WARNING: A bypass relay (or its driver) has a fault cleared. SEVERE: An internal UPS communication fault exists. INFORMATIONAL: An internal UPS communication fault no longer exists. WARNING: The specified Outlet Group command has been issued. SEVERE: Communication to the UPS when the UPS is on Battery. SEVERE: A UPS critical condition was detected. 7

UPS SNMP Trap Rule INFORMATIONAL: A UPS critical condition has been cleared. WARNING: A UPS warning condition has been detected. WARNING: A UPS warning condition has been cleared. INFORMATIONAL: A UPS informational condition has been detected. INFORMATIONAL: A UPS informational condition has been cleared. WARNING: Updating UPS firmware. INFORMATIONAL: Finished updating UPS firmware. INFORMATIONAL: UPS firmware update succeeded. WARNING: UPS firmware update failed. SEVERE: UPS has no valid firmware. INFORMATIONAL: UPS now has a valid firmware. WARNING: A local display button fault exists. INFORMATIONAL: A local display button fault no longer exists. SEVERE: UPS needs factory setup. INFORMATIONAL: UPS no longer needs factory setup. SEVERE: Emergency Power Off (EPO) active. INFORMATIONAL: Emergency Power Off (EPO) now inactive. SEVERE: A firmware mismatch error exists. INFORMATIONAL: A firmware mismatch error no longer exists. SEVERE: An oscillator error exists. INFORMATIONAL: An oscillator error no longer exists. SEVERE: The UPS is on battery due to an error. INFORMATIONAL: The UPS is no longer on battery due to an error. INFORMATIONAL: Trap used to test SNMP trap functionality. 6.4. Using SNMP traps SCUtils Monitoring APC UPS v2.0 supports monitoring with SNMP traps. Please make sure that SNMP Trap service is not running on the management servers belong to resource pools used for network monitoring. Fig. 2 Inactive SNMP Trap service Then set up APC UPS devices to send SNMP traps to specific events using IP address or hostname of the management server from the network monitoring resource pool. Specify SNMP v1, if required. Specify the same community string as in a discovery rule for that APC UPS device. Please refer to manuals of your APC UPS device or SNMP/web network management card for details. 8

The management pack contains of 100 rules for traps. For each rule you can specify your own Priority and Severity level using overrides. Please refer to the Operations Manager guide to details. The name of trap alert rule starts with UPS Alert trap Rule. Fig. 3 Overriding Priority and Severity. Severity defines the alert severity and can be one of the following values: 0 - Information 1 - Warning 2 Critical Priority defines the alert priority and the mapping, and it can be one of the following values: 0 - Low 1 - Medium 2 High 6.5. Reports SCUtils Monitoring APC UPS includes 11 reports available in the Reporting workspace. 9

7. Known issues and troubleshooting Here we describe the known issues. If you haven t found a solution in this section, please contact us at support@scutils.com. 7.1. Errors and warning during a discovery process During the first discovery you may see some of these errors and warnings being logged on the SCOM Management Servers: Initialization of a module of type "SnmpAsyncProbe" (CLSID "{2B72C326-CDBB-421A-ACC3- A1994DBD34BB}") failed with error code Unspecified error causing the rule "SCUtils.APC.UPS.Input.Phase.Rule.UPSInputPower" running for instance "Phase-1 on APCUPS1" with id:"{9a8ff3d5-b24f-ce64-0bad-56a5dtre3de71}" in management group "SCOM2012". These errors and warnings may be safely ignored. 10