Effect of Temperature on Torsional Properties of Ni-Ti and Copper Ni-Ti Orthodontic Wires

Similar documents
MECHANICAL AND ELECTRICAL PROPERTIES OF A NiTi SHAPE MEMORY ALLOY

Drum- and -Disc-Engine with Shape Memory Wires

Influence of Rapid Solidification on Ni50-xTi50Cox Shape Memory Alloys

Heat line formation during roll-casting of aluminium alloys at thin gauges

PROPERTIES OF Fe-Cr-Ni-Mn-Si (-Co) SHAPE MEMORY ALLOYS

COMPARATIVE STUDY OF MECHANICAL PROPERTIES OF VARIOUS Ni-Ti BASED SHAPE MEMORY ALLOYS IN VIEW OF DENTAL AND MEDICAL APPLICATIONS

The Effect of Nitrogen on Martensite Formation in a Cr-Mn-Ni Stainless Steel

Computerized simulation of thermal behaviour during forging sequences

Structure/property relationships in HSLA steel with low carbon and manganese and increased silicon content

ATOM PROBE ANALYSIS OF β PRECIPITATION IN A MODEL IRON-BASED Fe-Ni-Al-Mo SUPERALLOY

Selecting the components of composites

Simulation of Dislocation Dynamics in FCC Metals

CVD COATING OF CERAMIC LAYERS ON CERAMIC CUTTING TOOL MATERIALS

Densification superficielle de matériaux poreux par choc laser

Pressure effects on the solubility and crystal growth of α-quartz

THE INTERPRETATION OF ELECTRON DIFFRACTION PATTERNS FROM Ni-Al MARTENSITE

Finite Element Model of Gear Induction Hardening

Effects of temperature on monotonic and fatigue properties of carbon fibre epoxy cross ply laminates

NiTi WIRES FOR ORTHODONTIC APPLICATION

DISLOCATION RELAXATION IN HIGH PURITY POLYCRYSTALLINE ALUMINUM AT MEGAHERTZ FREQUENCIES

High Purity Chromium Metal Oxygen Distribution (Determined by XPS and EPMA)

Grain growth and Ostwald ripening in chromia-doped uranium dioxide

Stabilization of Austenite Associated with Prior Formation of Martensite

Precipitation mechanisms and subsequent hardening kinetics in the β-cez alloy

Physical properties of epoxy and free volume evaluated by positron annihilation spectroscopy

STRAIN RATE DEPENDENCE ON MECHANICAL PROPERTIES IN SOME COMMERCIAL ALUMINUM ALLOYS

Fatigue of High Purity Copper Wire

HIGH DAMPING IN GREY CAST IRON

LASER PROCESSING OF METAL-CERAMIC COMPOSITE MULTILAYERS

Non destructive observation by X-ray diffraction on a berlinite crystal

CHEMICAL VAPOR DEPOSITION OF IR-TRANSMITTING ZINC SULPHIDE

KPY 12 - A PRESSURE TRANSDUCER SUITABLE FOR LOW TEMPERATURE USE

PARTIAL HYSTERESIS CYCLES IN SHAPE-MEMORY ALLOYS : EXPERIMENTS AND MODELLING

Laser cladding of copper base alloys onto Al Si7 Mg0.3

EFFECT OF STRESS AND STRAIN ON MARTENSITIC TRANSFORMATION IN A Fe-Ni-Mo-C ALLOY WITH A HIGH Ms TEMPERATURE

DIFFICULTIES IN GRAIN REFINING ALUMINUM LITHIUM ALLOYS USING COMMERCIAL Al-Ti AND Al-Ti-Bor MASTER ALLOYS

APFIM AND FEM STUDY OF Mo-La ALLOY WIRE

Electrodeposition of Thin Film Cu-Zn Shape Memory Alloys

Phase transformation behavior of thin shape memory alloy wires embedded in a polymer matrix composite

Market Strategies for the Commercial Exploitation of Shape Memory Alloys

Real-Time Control of Resonance in Smart Shape-Memory Alloy Hybrid Laminates

Strength of 10CR-N martensitic steels

A new method of making metal matrix fibre reinforced materials

Induction hardening of small gear wheels made of steel 50CrMo4

The Effect of Stress Ageing on the Properties of Shape Memory Alloys

Ductility of Ultra High Purity Copper

Powder metallurgical processing of a SiC particle reinforced Al-6wt.%Fe alloy

Strain hardening of aluminium alloy 3004 in the deep drawing and ironing processes

Secondary recrystallization of oxide dispersion strengthened ferritic alloys

Electrical properties of interlevel deposited oxides related to polysilicon preparation

ELECTRONIC PROPERTIES OF SILICON INTERFACES PREPARED BY DIRECT BONDING

Athermal and Isothermal Martensitic Transformations Induced at Room Temperature by Ultra High Magnetic Field

SPECTROSCOPIC PROPERTIES AND OPERATION OF PULSED HOLMIUM LASER

Effect of the Hydrogen Induced Degradation of Steel on the Internal Friction Spectra

NANOINDENTATION-INDUCED PHASE TRANSFORMATION IN SILICON

Metal-ceramic joining by laser

STRUCTURAL RELAXATION AND CRYSTALLIZATION OF FeB AND NiP METALLIC GLASSES FOLLOWED BY INTERNAL FRICTION AND MODULUS MEASUREMENTS

HYSTERETIC DAMPERS FOR PROTECTING STRUCTURES DURING EARTHQUAKES

BRIDGMAN GROWTH AND PROPERTIES OF LuAlO3-Nd3+ LASER CRYSTALS

PHOTOCONDUCTIVITY IN a-si : H AND a-sixc1-x : H, CORRELATION WITH PHOTOLUMINESCENCE RESULTS

MARTENSITIC TRANSITION ENTROPY CHANGE AND ELASTIC CONSTANTS OF Cu-Al-Be ALLOYS

ELLIPSOMETRY OF NICKEL-OXIDES AND -HYDROXIDES IN ALKALINE ELECTROLYTE

BALLISTIC PERFORATION OF POLYCARBONATE SHEET AND ITS HIGH STRAIN RATE RESPONSE

Mechanism of two Way Shape Memory Effect Obtained by Stabilised Stress Induced Martensite

Magnetic pulse deformation of tubes made of partially polymerised carbon fibre reinforced plastic

EPITAXIAL GROWTH AND SOME PROPERTIES OF SAMARIUM CRYSTALS ON TUNGSTEN

Effect of Deformation and Thermal Treatment of NiTi Alloy on Transition Sequence

Carbon-free sliding interface in sol-gel processed SiC Nicalon fiber-refractory oxyde matrix composites

Impact of cutting fluids on surface topography and integrity in flat grinding

Hot Forging of a Cladded Component by Automated GMAW Process

THERMAL PULSE ANNEALING OF TITANIUM AND TANTALUM SILICIDES

Evolution of the porous volume during the aerogel-glass transformation

THE INFLUENCE OF STRAIN-RATE, AMPLITUDE AND TEMPERATURE ON THE HYSTERESIS OF A PSEUDOELASTIC Cu-Zn-Al SINGLE CRYSTAL

Interaction between mechanosorptive and viscoelastic response of wood at high humidity level

STRUCTURES OF AMORPHOUS MATERIALS AND SPECIFIC VOLUME VARIATIONS VERSUS THE TEMPERATURE

RESPONSE OF AISI TYPE 316 STAINLESS STEEL TO INTERRUPTED QUASI-STATIC TO IMPACT TENSION AT ELEVATED TEMPERATURES

Growth kinetics of copper thin films in different MOCVD systems

INTERDIFFUSION OF Au/Ni/Cr ON SILICON SUBSTRATE

Cr3+-SENSITIZATION OF THE 3µm Er3+: YAG LASER

POSSIBILITIES AND LIMITATIONS OF LASER SURFACE ALLOYING BY MELTING OF PREDEPOSITED LAYERS

SURFACE ACOUSTIC WAVE ATTENUATION IN THIN FERROMAGNETIC FILMS

Continuous Casting of Aluminum and Copper Clad Ingots under Electromagnetic Fields

New experimental method for measuring the energy efficiency of tyres in real condition on tractors

Collusion through price ceilings? In search of a focal-point effect

Isothermal Martensitic Transformation as an Internal-Stress-Increasing Process

Bonding of aluminium matrix composites for application in the transport industry

AMM079 การประช มว ชาการเคร อข ายว ศวกรรมเคร องกลแห งประเทศไทยคร งท ต ลาคม 2548 จ งหว ดภ เก ต

ATOM-PROBE ANALYSIS OF ZIRCALOY

CHARACTERISTICS OF FERRITE ELECTRODES

HYDROGEN SEGREGATION AND DIFFUSION AT GRAIN BOUNDARIES

Characterising the impact of surface integrity on the fatigue behaviour of a shot-peened connecting rod

Silicon carbonitrides - A novel class of materials

How Resilient Is Your Organisation? An Introduction to the Resilience Analysis Grid (RAG)

Plasticity criterion for hot forming of Aluminum-Lithium alloy

LASER CLADDING BY POWDER INJECTION : OPTIMIZATION OF THE PROCESSING CONDITIONS

STUDY OF THE HYGRO-MECHANICAL BEHAVIOR OF CORRUGATED CARDBOARD

FATIGUE BEHAVIOR OF PEARLITIC S.G. CAST IRONS AFTER LASER SURFACE HEAT TREATMENTS

THE EFFECT OF DYNAMIC LOADING ON THE STRUCTURE AND PROPERTIES OF 18G2A AND 14HNMBCu STEELS

Influence of cold rolling and fatigue on the residual stress state of a metal matrix composite

Time decay of the excited states of Eu+2 in europium-doped LMA

Transcription:

Effect of Temperature on Torsional Properties of Ni-Ti and Copper Ni-Ti Orthodontic Wires M. Filleul, R. Portier, L. Jordan To cite this version: M. Filleul, R. Portier, L. Jordan. Effect of Temperature on Torsional Properties of Ni-Ti and Copper Ni-Ti Orthodontic Wires. Journal de Physique IV Colloque, 1997, 07 (C5), pp.c5-661- C5-665. <10.1051/jp4:19975105>. <jpa-00255605> HAL Id: jpa-00255605 https://hal.archives-ouvertes.fr/jpa-00255605 Submitted on 1 Jan 1997 HAL is a multi-disciplinary open access archive for the deposit and dissemination of scientific research documents, whether they are published or not. The documents may come from teaching and research institutions in France or abroad, or from public or private research centers. L archive ouverte pluridisciplinaire HAL, est destinée au dépôt et à la diffusion de documents scientifiques de niveau recherche, publiés ou non, émanant des établissements d enseignement et de recherche français ou étrangers, des laboratoires publics ou privés.

J. PHs. IV FRANCE 7 (1 997) Colloque C5, Supplkment au Journal de Physique I11 de novembre 1997 Effect of Temperature on Torsional Properties of Ni-Ti and Copper Ni-Ti Orthodon tic Wires M.P. Filleul*'**, R. Portier* and L. Jordan*'*** * Laboratoire de Me'tallurgie Structurale, ENSCP, 11 rue Pierre et Marie Curie, 75231 Paris cedex 05, France ** Faculte' de Chirurgie Dentaire, Universitk Rene' Descartes Paris Paris, France *** Faculte' de Chirurgie Dentaire, Universite' Denis Diderot Paris VII, Paris, France Abstract.The behaviour of Ni-Ti and Copper Ni-Ti orthodontic wircs was tcsted undcr induccd torsion in controlled conditions of moment and temperature. The results clearly demonstrate a great diffcrcncc in the behaviour of thcsc wires. The loading and unloading curves and plateau rcgions were found to bc closcly mlatcd to tcmpcraturc. Experiments carried out in conditions of identical toision revealed significant variations in stiffness duc to changcs in mouth temperature. Divcrsity of reaction to stress is linked to the crystalline struclurc of the alloys. 1. INTRODUCTION Knowledge of the magnitude of torque applied to the tooth for a given amount of torsion on orthodontic wires is of the utmost importance to the clinician. Orthodontists have long varied the forces by changing the thickness of the same alloy wires in order to move the teeth. Today new alloys are available which could be used to modulate forces of identical cross-section wires1 11. Researchers have studied orthodontic wires under bending [2-31 but few torsion experiments have been reported. The behaviour of wires under torsion is very different from their behaviour under flexion and this due to the fact that distance between orthodontic brackets induces different stiffness of the arch-wire depending on whether flexion or torsion is applied. Thus, the inter-bracket distance varies by third power law in flexion whereas in torsion the variation is linear. The purpose of this study was to test Ni-Ti and Copper Ni-Ti orthodontic wires in torsion. Evaluation and comparison of their pseudoelastic properties (superelastic and memory effect) are dealt with in this paper. Superelasticity and memory effect are linked to structural changes at certain temperatures 141. The stn~ctural state at high temperature is that of the austenite, and at low temperature it is that of the martensite or the R- phase (depending on the alloy used)[5-6.1. The results will then be discussed using Differential Scanning Calorimetry (DSC). This method allows identification of the c~ystallographic phases of alloys at various temperatures [7]. 2. MATERIALS AND METHODS An original testing bench (figure 1) was used to test orthodontic wires under induced torsion in controlled clinical conditions of moment and temperature [8]. The system is immersed in a thermostatically controlled waterbath. The tests on torsion are conducted at the level of the right centntl incisor. In clinical conditions, moments of more than 1400 g.mm are not generally applied to central incisors, but the test was performed at higher values than normal in order to observe the wire properties. To study superelasticity, each wire was loaded at 22' C (room temperature) with molnents varying from 0 g.mm to 1680 g.mm and was unloaded at 37OC (buccal temperature). To study memory effect, thc arch wires were cooled at O C and were loaded at 10 C in order to measure the degree increase when moments varied from 0 g.mm to 1260 g.mm and when they were unloaded at 37 C. The values of torsion angles (degrees) are plotted on six graphs (figures 2 to 7). Four commercial orthodontic archwires were studied (Table 1). All the wires were available as preformed archwires. The exact composition and thermo-mechanical treatments of these wires are unknown. The archwires were submitted to torsion tests in order to evaluate the restored torclue. Restored moments of different Ni-Ti alloys are compared to those of stainless steel in the sa~iie conditions. The section of brackets bonded to the dental arch simulator is 0.018 x 0.025 inches (0.46 x 0.64 mm2) and the section of -'the tested wires is 0.017 x 0.025 inches (0.435 x 0.64 1iim2) or 0.01 S s 0.025 inches (0.36 x 0.64 mm2). Article published online by EDP Sciences and available at http://dx.doi.org/10.1051/jp4:19975105

JOURNAL DE PHYSIQUE IV Figlire I : The resting bench - A dentul arch simulutor ; B lever ; C ship of iron ; D gruduuredpul1e.v. E weight ; F rhertno.stutic bobbing lzeurer. Table I : Details on the various urcrhwires used. Differential Scanning Calorimetry measurements (DSC) were used to determine the transfornption temperatures of these Ni-Ti wires. DSC measurements were performed by a Mettler 30mA 4000 machine. The coolinglheating rate is S C/min. The DSC samples of the wire were cut at the level of the central incisor. The different transformation temperatures are presented on Table 2. The transformations were exothermic on cooling, and endothermic on heating. Table 2: Transformaion temperatures determined by DSC during cooling or heating. The DSC experiments show that it is the A - R transformation which occurs in the case of US Ni-Ti@ and Neo Sentalloy FlW, and the A - M transformation which occurs in the case of Copper Ni-Ti 358 and Copper Ni-Ti m.

In order to study superelasticity, each wire is loaded at 22OC and unioaded at 37OC. To observe memory effect, the wires are loaded at 10 C and unloaded at 37OC. In the graphs, the thin lines correspond to the loading wire and the thick lines to the unloading wire. There is a certain gap between the section of these wires and the brackets. Torsion play is evaluated at 4.5' maximum [9]. This explains the behaviour of wires in the first 4-5Odegrees of torsion. Stainless steel i Figure 2 : Curves of US Ni-Ti @. Figure 3 :Cwve.s of' Neo Sentalloy F 200 @. US Ni-Ti@ (fig. 2): With superelastic and memory effects, the unloading slopes are similar, only the unloading plateaux are different. The loading slopes are more gradual than the unloading slopes in the case of two properties. Neo Sentalloy@ (fig. 3) and Copper Ni-Ti 35@ (fig. 4) show the same behaviour in memory effect : the loading slope is more gradual than the unloading slope. This is not the case with superelasticity : the loading and unloading slopes are similar. Copper Ni-Ti 40@ (fig. 5) curves are similar to Copper Ni-Ti 358 curves in memory effect, but the plateau level is inferior. In superelasticity, the loading slope is more gradual than the unloading slope. After unloading, this wire shows a certain deformation which is greater in superelasticity than in memory effect. Figures 2 to 5 show that the temperature does not modify the elastic behaviour of stainless steel. g.mm 1820 1680 1540 1400 Stainless steel 1260 1120 980 840 700 560 420 280 140 0-5 0 5 10 15 20 25 30 35 40 45 SO 55 611 Figure 4 : Curves of Copper Ni-Ti 35 8. Figure 5 : Curves of Copper Ni-Ti 40 @. A11 the diagrams show characteristic curves of superelasticity and memory effect. All the curves in torsion present, on loading, a slope followed by what is more or less a plateau and, on unloading, a plateau

C5-664 JOURNAL DE PHYSIQUE IV followed by a slope. All the wires in memory effect show an unloading plateau which is lower than that recorded for superelasticity. Apart from Copper Ni-Ti 408, all the wires, after unloading, return to their original shape. This behaviour during unloading is very important : it corresponds to tooth movement. Superposition (fig. 6 and 7) of the curves of different wires permits a comparison between.superelasticity and memory effect. Figure 6 : Ssiperelnsticiry. Fixr~rc! 7 : Mcnzory cff'ect Analysis of these different wires allows them to be classified in order of decreasing restored moment at the plateau values level (table 3). This order is not the same for superelasticity and memory effect. Memory effect MUS Ni-Ti > M~o~~crNi-~i 35 > MNS Fl(X) > M~oppcrNi-Ti 30 : Sllperelasticity : Ni-Ti > MNS F100 > M~op~crNi-~i 35 > M~o~)~crNi-Ti 40. Memory cff'cct S~rp~rcla~sticity Wire Torsion Restored M Torsion Restored M P, (g.mm) (O) (g.mm) US Ni-Ti8 57 -+ 20 1260 57 4 21 16804 1330 Copper Ni-Ti 350 57 -+ 15 700 57 -+ 20 1050 -+ 980 Neo Sentalloy F1000 57 -+ 20 630 57 + 12 1 120-3 700 Copper Ni-Ti 408 57-3 15 560 57-+ 11 630 -+ 280 Table 3 : Restored moments in memory cffi!cr trtd.sr~ppercltr,sricir~ (11 the pktrtetrr~u 1cvcl.s. These torsion tests show the difference of behaviour of Ni-Ti and Copper Ni-Ti wires rider similar stress when environmental temperatures change. Diversity of reaction to stress is linked to the cryst ;I 11' ~ne strttcture of the alloys, and this is investigated by DSC (Table 2). 4. DISCUSSION The DSC graphs during cooling give the structural state of the wires before loading at a certain temperature, and thus, during heating, enable us to estimate the behaviour of the wire during unloading (when teeth are moving). Stainless steel does not show any transformation at buccal temperature. Magnitude of stress applied to the teeth is not linked to buccal temperi~t~~re. Loading and unloading slopes are the same. US Ni-Ti@ : The transformation from tile ziustenitic state to the R-phase takes place at 245 C. This explains why the slope of the curve at 22 C is lower than the slope of the curve at 37 C. At 22"C, on loading, the material is certainly biphased (austenite and R-phase) and at 37OC, it is in the austenitic phase. In fact, the R-phase elastic modulus is much lower than the austenitic phase. After cooling at O C, the material is entirely in R-phase and the loading slope at 10 C is lower than that at 22 C. For the same amount of torsion of an edgewise wire, the developed moments at 10 C will be weaker than those developed at 22OC.

After unloading, the wire returns to its original shape (0' torsion) because the reverse transformation (R -t A) is finished at 29OC, a temperature which is lower than buccal temperature. In the case of Neo Sentalloy F1008, at 22OC when stress is applied, the material is austenitic (TR = 21.7OC), and the mechanical energy applied during loading is sufficient to allow the R-phase to appear. The orthodontist can advantageously use superelasticity. After cooling at O C, the material is entirely in R-phase and the orthodontist can use memory effect. After unloading, as in the case of US Ni-Ti@, the wire returns to its original shape (0' torsion) because the reverse transformation (R -+ A) finishes at 27.2OC. The A tt R transformation is used for US Ni-Ti8 and Neo Sentalloy F1008 because the transformation temperatures to martensite are too low. In superelasticity, this wire shows an unloading plateau of 1600 g.mm which is too high a level for a central incisor. Copper Ni-Ti, which is characterized by direct transformation from austenite to martensite, never experiences the R-phase (Table 2). DSC measurements of Copper Ni-Ti 358 during cooling show that the martensitic transformation (Ms) occurs at 17S C (Table 2). When the wire is loaded at 22OC, it is in the austenitic phase. Thus, the loading and the unloading curves for superelasticity are the same. A load of 910 g.mm allows the martensitic phase to appear and thus the orthodontic wire develops superelastic behaviour. When the wire is cooled at O C, the material is partially martensitic (Mf : -8.5OC). Therefore, the loading slope is Inore gradual than the unloading slope. At buccal temperature (37"C), the wire, after unloading, presents no permanent deformation because the reverse martensitic transformation is finished at 363 C. The transformation temperature of Copper Ni-Ti 408 from austenite to martensite begins at 20.2OC. Thus, a load of 560 g.mm is enough to provoke the superelasticity. The restoring moments delivered by this wire are weaker than those delivered by Copper Ni-Ti 358. After cooling at O C, the material is completely martensitic (Mf : 3OC). Hence, the loading slope is more gradual than the unloading slope. At 37OC, the wire remains partially martensitic because the transformation ends at 40 C. Thus, after unloading, a permanent deformation remains : < So torsion. But Copper Ni-Ti 408 wire could return to 0' torsion only if the patient ate hot food. The restored moments of Copper Ni-Ti 408 are weaker than those observed in the case of the other wires. 5. CONCLUSIONS Experimental study of Ni-Ti and Copper Ni-Ti alloy orthodontic wires in torsion give rise to the following observations. Compared to stainless steel archwires, these wires can produce slight forces and are able to endure great deformation in torsion without undergoing permanent deformation. The present results show that, in most cases, these wires have the ability to exhibit a plate:^^ on unloading and thus produce a constant orthodontic force. Thus they provided the optimal conditions for tooth movement 1101. The level of the forces applied to the teeth depends on the transfor~nation temperatures of Ni-Ti and Copper Ni-Ti wires in relation to buccal temperature. The orthodontist can profitably use superelasticity or memory effect according to the clinical case. The clinician can choose between superelasticity and memory effect depending on the unloading level he is aiming at. During loading, the wire can easily be placed in the bracket without running the risk of bonding failure. Ni-Ti wires have other advantages like a reduction in the number of archwire changes needed to align teeth 11 I]. References [I] Burstone C. J., Am. J. Orthod. 80 (1981) 1-16. [2] Miura F., Mogi M., Ohura Y. and Hamanaka H., Am..I. Orthocl. Denrofnc. Orthop. 90 (1986) 1-10. [3] Tonner R. I. M. and Waters N. E., Eur..I. Orthod. 16 (1994) 409-419. 141 Guenin G., Techniques de l'lnge'nieur 10 (1986) 1-11. [5] Miyazaki S. and Otsuka K., Metall. Trans. 17A (1986) 53-63. [6] Jordan L., Chandrasekaran M., Masse M. and Bouquet G.,.I. Phys. IV5 (1995) 489-494. [7] Jordan L., Masse M., Collier J.Y.and Bouquet G., J. Phy.s. IV4 ( 1994) 157-162. [8] Filleul M.P., French patent N089/06480 (1989). [9] Creekmore T. D., J. Clin. Ortliocl. 13 (1979) 305-310. [lo] Baron R., Rev. Orthop. Dento Fuc 9 (1975) 309-325. [ll] Bishara S., Winterbottom J., Sulieman A.H., Rim K. and Jakobsen J., Angle Orthod. 65 (1995) 117-122.