PRESENTS... SOLVENT CEMENTING PLASTIC PIPE. and FITTINGS

WARNING SOLVENT WELDING INSTRUCTIONS AQUARISE SAFE HANDLING AND STORAGE OF PIPE, FITTINGS & VALVES SOLVENT WELDING SOLVENT WELDING BASICS

Guide to Solvent WeLDing PVC and CPVC Plastic Pipe and Fittings

Guide to Solvent Cementing PVC and CPVC Plastic Pipe and Fittings

PVC CEMENTS PRIMER 8155 CLEANER 7120

Solvent Welding Guide PVC, CPVC AND ABS PIPE & FITTINGS. We build tough products for tough environments IPEX CEMENTS, PRIMERS & APPLICATORS

To consistently make good joints, the following should be carefully understood:

Solvent Cementing Guide PVC, CPVC AND ABS PIPE & FITTINGS. We Build Tough Products for Tough Environments IPEX CEMENTS, PRIMERS & APPLICATORS

INSTALLATION STANDARD FOR PVC COLD WATER BUILDING SUPPLY AND YARD PIPING IAPMO IS

Insert Fittings. For Use With Polyethylene Pipe. PRICE SCHEDULE INS Effective October 26, 2009 Supersedes INS

DOUBLE CONTAINMENT DESIGN & INSTALLATION GUIDE

Based on World's best Japanese Material and Technology The latest, cost effective and reliable plumbing system for Hot and Cold water

Double Containment DESIGN & INSTALLATION GUIDE TECHNICAL INFORMATION. Visit our web site

Installation. Plastic Piping Tools Tools used with Plastic Piping

Installation Standard For PVC BUILDING DRAIN, WASTE AND VENT PIPE AND FITTINGS IAPMO IS

SOLVENT WELDING INSTRUCTIONS

IAPMO IS INSTALLATION STANDARD FOR CPVC SOLVENT CEMENTED HOT AND COLD WATER DISTRIBUTION SYSTEMS

Foamed-in-place insulation Sprayed insulation. Spray Foam Insulation for Residential Building Envelope Insulation

OPERATION, SAFETY & PROCEDURE GUIDELINE MANUAL FOR

WESTERN UNDERGROUND COMMITTEE GUIDE 3.4 (3.4/00/0565)

Wabo FireShield Model: FSH

All Low VOC All the Time

Installation Guide SUBFLOOR ADHESIVE CONTENTS

INSTALLATION STANDARD FOR ABS BUILDING DRAIN, WASTE, AND VENT PIPE AND FITTINGS IAPMO IS

FOREWORD. Issam Kairy Kabbani. Chairman of IKK Group of Companies

!!Prompt attention to any injury usually will minimize what may become serious if neglected!!

Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification:

PVC Project Assembly Guide a FORMUFIT field manual

Spears Low VOC Solvent Cements, Primers & Accessories

Installation Methods for IPEX System 636 Type BH Class IIA (PVC) and Class IIB (CPVC) Gas Venting Systems

Application Guidelines

th Edition. ESLON SCH80 PVC & CPVC Piping Systems Specifications & Engineering Manual

INSTRUCTION MANUAL WARNING: BEFORE USING THE MACHINE READ THE INSTRUCTION MANUAL CAREFULLY!

introduction Submittal Data Sheet Job or Customer: Engineer: Contractor: Submitted by: Approved by: Order No: Specification: < STANDARDS >

OUR NAME IS OUR BOND

HYDRONIC PIPING CHAPTER 12

CPVC CTS PRODUCTS DESIGN AND INSTALLATION MANUAL

HYDRONIC PIPING CHAPTER 12

INSTALLATION STANDARD FOR CPVC SOLVENT CEMENTED HOT AND COLD WATER DISTRIBUTION SYSTEMS IAPMO IS

2016 Midwest Bridge Preservation Partnership

Self Adhesive EPDM TRAINING MANUAL

419D Overcoat Pen Technical Data Sheet 419D-Pen

Installation Instructions

WE01S GMA (MIG) Plug Weld

Short Form Guide Specification. STYROFOAM CAVITYMATE Ultra Air Barrier Wall System

INDOOR RUBBER FLOORING INTERLOCKING INSTALLATION / MAINTENANCE GUIDELINES MARATHON SERIES. Four-Side Interlock Loose Lay Installation

ASSEMBLY INSTRUCTIONS FOR. Unitec PVC Adhesive. OPERATION AND ASSEMBLY INSTRUCTIONS FOR PVC pipe mounting

Features 100% solids Moisture curing urethane Rapid rate of strength build up Open time from 2-4 minutes Set times from seconds

aquapanel InstallatIon GuIde

Corzan CPVC Schedule 80 Iron Pipe Size (IPS) Pipe, Valves and Fittings Sample Specification: Hot and Cold Water Distribution

Fast Cure Acrylic Adhesive

WE11S GMA (MIG) Fillet Weld

Refer to Substrates & Surface Preparation.

WE21S GMA (MIG) Butt Joint With Backing

VOCs and Solvent Cements

FIRESTOPPING & SMOKE SEALS

INTRODUCTION TO THE PROGRAM

Insert Fittings. For Use With Polyethylene Pipe. PRICE SCHEDULE INS Effective September 26, 2010 Supersedes INS

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

1. PREPARATION 2. INSTALLATION 3. FINISHING 4. MAINTENANCE

Pipeline Accessories. PSI Wall Sleeves. General Information Selection Guide Technical Data Installation Instruction

ATT-42/95 SAMPLING, Asphalt

LUXAPOOL CHLORINATED RUBBER POOL COATING

Red Insulating Varnish 4228 Technical Data Sheet 4228-Liquid

1. Install product according to ASTRAL's Installation instructions and manual and follow recommended safe work practices.

POLYMER CONCRETE 800 NON-SHRINK VINYL ESTER POLYMER CONCRETE, CONCENTRATED HYDROFLUORIC ACID RESISTANCE

PVC Duct (DB2/ES2) Pipe & Fittings. For usage in direct burial and concrete encased applications

optimum glue Preparation INSTALLATION INFORMATION We recommend to order all panels for the same commercial flooring project at the same time.

Quality NBR Insulation

PRICES: DESIGN: TAXES:

Inject-TITE AW All-Weather

Extended Working Time Epoxy

Florida Keys Aqueduct Authority. Lateral Connection Construction Packet

LAMINATE GENERAL INSTALLATION INSTRUCTIONS FOR DROP LOCK FLOORING

STERI-FLAKE 470 HYBRID ESTER POLYMER, LIGHT-MEDIUM TRAFFIC, FLAKE FILLED FLOOR SYSTEM LOW ODOR MMA ALTERNATIVE FEATURES

Nanoman Anti-Rust & Corrosion TDS

Premium Acrylic Conformal Coating 419D Technical Data Sheet 419D-Liquid

OPERATION MANUAL. A220 Arc Welding Machine. Serial Number: Where Purchase: Date of purchased:

SECTION SELF-ADHERING SHEET WATERPROOFING CCW-711

GULF COAST PAINT MFG., INC

THE BRITE THING TO DO

All Low VOC All the Time

ARDEX GUIDE SPECIFICATION ARDEX SD-M Designer Floor Finish

Florida Keys Aqueduct Authority. Gravity Sewer Lateral Connection Construction Packet

LOCTITE HC AERO

HARRISON SUPERDUCT HARRISON FUME EXHAUST SYSTEMS MACHINE & PLASTIC CORPORATION SPECIFICATIONS CATALOG

BP U.S. Pipelines and Logistics (USPL) Safety Manual Page 1 of 8

Guide Specification for the OSI QUAD Window and Door Flashing System

IMTECH ADHESIVE SYSTEMS

RENEW ELASTOMERIC ACRYLIC COATING (PAINT GRADE) MANUFACTURERS SPECIFICATION / SECTION

Solventless, two-component, cross-linked epoxy. Epoxies lose gloss, discolour and eventually chalk in sunlight exposure.

Objectives. Identify hazards in the shop. Learn about protective clothing. Understand the dangers of fire, electricity, fumes, cylinders, and machines

INTELLIGENT WATER FLOW METERS. Installation Guide

Inject-TITE FS Fast-Set

Protective Coatings for Underground Utility Concrete Structures. By: John E. Davis Inside Sales & Marketing Specialist: Sauereisen, Inc.

***********************************************************************************

SECTION A. Schönox AP- Synthetic Gypsum Self Leveling Underlayment. B. Schönox VD-Primer for porous substrates

Home Stretch Liquid Waterproofing Fluid Applied Waterproofing Membrane

20-30 mils ( microns) per coat mils ( microns) in two or more coats

IPEX Solvent Cements Catalogue

Transcription:

PRESENTS... SOLVENT CEMENT WELDING & PLASTIC PIPE and FITTINGS

1 READ THIS BOOK AND FOLLOW DIRECTIONS ON CANS Even if you have installed PVC or CPVC pipe and fittings before!

2 ASSEMBLE MATERIALS NEEDED Safety glasses and gloves. Clean rags, tape measure, and marking pen. Knife and deburring tool (or file). Miter box, saw or wheel cutter. Right primer and cement for the kind and size of pipe and fitting you are installing. Right size applicator for specific pipe size being used.

3 CUT PIPE SQUARE One good way is with a saw and miter box. A wheel type cutter designed for plastic may also be used. Cutaway view of pipe

BEFORE BURRS 4 REMOVE BURRS with a file or deburring tool Bevel all pipe-ends. Remove all burrs. AFTER 3 /32 10-15 o

5 CLEAN PIPE WITH RAG To remove dirt and moisture that can interfere with the solvent welding process of pipe joint.

6 CHECK DRY FIT Fitting should go over end of pipe easily but become tight about 1 / 3 to 2 / 3 of the way on. A good fit can be assured of by using pipe and fittings that meet applicable ASTM standards and code approvals. 1 /3 to 2 /3 interference fit Pipe Fitting Now you are ready to solvent weld. Turn the page and read on...

7 APPLY WELD-ON PRIMER to fitting...then pipe...and to fitting again I skipped this step once and the cost of repairing leaks is expensive so ALWAYS use a primer on pressure systems and in cold weather. The primer softens the surfaces prior to solvent welding the joint. Check primer penetration and softening of the joining surface.

8 APPLY WELD-ON CEMENT WHILE PRIMER IS STILL WET... Apply cement to pipe with proper applicator, then a thin coat in the fitting, then pipe again... Keep applicator in cement between applications... Keep can closed when not in use. (10) Rotations Minimum You should use an applicator at least 1/2 the size of the pipe.

9 WORK QUICKLY WHILE APPLYING CEMENT...But, do not puddle the cement inside the fitting or let cement run down inside of pipe.

10 ASSEMBLE IMMEDIATELY Be sure to bottom pipe in socket while both surfaces are still wet, twist the fitting a 1 / 4 turn while inserting, then... Twist fitting 1 / 4 turn

11...HOLD FOR ABOUT 30 SECONDS TO AVOID PUSHOUT Get help on large pipe sizes* or use mechanical helpers! *refer to large diameter solvent welding video at www.weldon.com/technical_support

12 WIPE OFF EXCESS CEMENT Especially the bead......but don t disturb the joint.

13 WAIT BEFORE DISTURBING For recommended set times, see set schedule on page 22. This will be a good time to take my lunch break!

14 PUT IN DITCH CAREFULLY...And carefully means DON T KICK IT IN!

15 SNAKE PIPE IN DITCH From side to side!

16 SHADE PIPE WITH BACKFILL Leaving joints exposed for inspection!

17 CURE PERIOD WILL DEPEND ON... 1 Thickness of cement 2 Pipe Diameter 3 Air temperature / humidity 4 Dry joint tightness For recommended cure times, see cure schedule on page 22.

18 REMEMBER... LONGER SET AND CURE PERIODS are required for larger diameter pipe, slow-drying cements, loose fit joints, chemical applications and in damp or humid weather conditions.

19 BRING PIPE TO ABOUT IT S OPERATING TEMPERATURE BEFORE TESTING & BACKFILLING This can be done by... 1 Shading with backfill 2 Filling with water at about operating temperature 3 Letting it stand overnight

20 HYDROSTATIC PRESSURE TEST...with water only, do not test with compressed air or gas. CONGRATULATIONS! If you ve followed instructions correctly, the joints are solvent welded and the piping system is ready to use. Pat yourself on the back for a job well done.

21 THINK SAFETY. WORK SAFELY. Check! 33 Cement and primer are flammable. Keep them away from sparks, heat, flame and other sources of ignition. 33 Do not smoke, eat, or drink when using solvent cement and primer. 33 Work in well ventilated area. Avoid breathing the solvent vapors. Wear NIOSH approved respirators when working in area with inadequate ventilation. 33 Wear proper protective equipment (safety glasses and gloves). 33 Keep container closed when not in use. Store cement and primer according to directions on the label. 33 When in doubt, read the product SDS and technical data sheet for more information. DANGER: Weld-On products must never be used in PVC and CPVC systems being used or tested by compressed air or gases.

Temperature Range AVERAGE INITIAL SET SCHEDULE FOR WELD-ON PVC/CPVC SOLVENT WELDS* Pipe Sizes ½ to 1¼ Pipe Sizes 1½ to 2 Pipe Sizes 2½ to 8 Pipe Sizes 10 to 15 Pipe Sizes 15 + 60-100 F 2 minutes 5 minutes 30 minutes 2 hours 4 hours 40-60 F 5 minutes 10 minutes 2 hours 8 hours 16 hours 0-40 F 10 minutes 15 minutes 12 hours 24 hours 48 hours Note: Initial set schedule is the necessary time to allow before the joint can be carefully handled. In damp or humid weather allow 50% more set time. Relative Humidity 60% or less Temperature range during assembly and cure periods AVERAGE JOINT CURE SCHEDULE FOR WELD-ON PVC/CPVC SOLVENT WELDS* Cure Time Pipe Sizes ½ to 1¼ up to 160 psi above 160 to 370 psi Cure Time Pipe Sizes 1½ to 2 up to 160 psi above 160 to 315 psi 22 Cure Time Pipe Sizes 2½ to 8 up to 160 psi above 160 to 315 psi Cure Time Pipe Sizes 10 to 15 up to 100 psi Cure Time Pipe Sizes 15 + up to 100 psi 60-100 F 15 min 6 hrs 30 min 12 hrs 1½ hrs 24 hrs 48 hrs 72 hrs 40-60 F 20 min 12 hrs 45 min 24 hrs 4 hrs 48 hrs 96 hrs 6 days 0-40 F 30 min 48 hrs 1 hour 96 hrs 72 hrs 8 days 8 days 14 days Note: Joint cure schedule is the necessary time to allow before pressurizing system. In damp or humid weather allow 50% more cure time. * These figures are estimates based on testing done under laboratory conditions. Field working conditions can vary significantly. This chart should be used as a general reference only. AVERAGE NUMBER OF JOINTS/QT. OF WELD-ON WELD** Pipe Diameter ½ ¾ 1 1½ 2 3 4 6 8 10 12 15 18 Number of Joints 300 200 125 90 60 40 30 10 5 2-3 1-2 ¾ ½ **These figures are estimates based on our laboratory tests. Due to the many variables in the field, these figures should be used as a general guide only.

WE TAKE IT SERIOUSLY... We hope you benefit from our lighthearted approach to a serious subject. we do take it seriously. The quality of the solvent welded joint determines the effectiveness of the plastic pipe system as a whole. For this reason, we offer data sheets, booklets, an installation video, installation training and qualification seminars as a complete educational package to those who take good joining techniques as seriously as we do. For more information, contact us at: Weld-On Adhesives, Inc. 455 W. Victoria Street, Compton, CA 90220 USA Customer Service: 1.800.888.8312 Technical Service: 1.877.477.8327 Website: www.weldon.com Lit. #230105 2013 WELD-ON 04-2013 IC