Chemcap Clearview is ideal for the safety conscious laboratory

Similar documents
CHEMCAP CLEARVIEW Ductless Fume Cabinets & Hoods

Ductless Fume Cabinets & Hoods

Ductless Fume Cabinets & Hoods

Ductless Fume Cabinets & Hoods

Fume Cabinets. iab. Order by phone Order on-line Order by fax Website

MONAIR. Recirculating Fume Cabinet. Low cost, efficient and State-of-the-art design. Reliability and safety assured

FASTER ChemFAST. Laboratory Fume Cupboards PROTECTION, SAFETY, RELIABILITY. AND MORE.

CLASS I MICROBIOLOGICAL SAFETY CABINET - BIO 1

Ductless Enclosures, Low-Profile Horizontal Design

UNIVERSITY POLICY STATEMENT S3/14 FUME CUPBOARDS. 1. Introduction

Designed for Storage of Noxious and Odorous Evidence

Mobile Ductless fume hoods with modular filtration column

Containment Booths. FOR MORE INFORMATION ON CONTAINMENT BOOTHS CALL +44 (0) OR

DPX fume extraction systems

Models: Acm l LAMINAR AIR FLOW. (Vertical)

DUCTLESS FUME HOODS labopur NF X MAY CLASS 2

Indoor Air Quality Solutions

HIGH EFFICIENCY AIR PURIFICATION SYSTEMS FOR DATA CENTERS quatroair.com AIR TECHNOLOGIES INC.

UBC Technical Guidelines Section Edition Fume Hoods Page 1 of 5

Standard Operating Procedures for Servicing Laboratory Exhaust Systems

Laboratory Bench Brochure Table Frame Range

ACD. Extraction and Filtration Technology for Odours, Gases, and Vapours. Extraction. Filtration. Persistence.

Ductless filtering fume hoods and vented storage cabinets. Designed for user safety, energy savings and environmental protection.

FlyerEquipmentWelding_04.indd 1

Designed for user safety, energy savings and environmental protection. an erlab product 02/2012

Clean Air Cut Cell TM

workstationindustries.com Made in the USA

FUME CUPBOARDS: SELECTION, INSTALLATION, MAINTENANCE AND DECOMMISSIONING

Designed for user safety, energy savings and environmental protection. an erlab product 06/2012

Filter Media 452 sq. ft. (42 sq. m) Accu-Rated Airflow 900 cfm (425 L/sec.) Sound Level Approximately 77 dba at 5 ft. (1.5 m)

Presenter: Wayne Wood, CIH, ROH, MScA. Director EHS, McGill University

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

W SERIES. Portable and wall-mount weld fume collectors

TECHNOLOGY FOR THE WELDER S WORLD. Room to Breathe!

IP-5(Dust-Solid Particles) 5(Liquid-Water Oil)

Model FD 115 Drying and heating chambers Avantgarde.Line with forced convection

lindab we simplify construction LindabAbsolute Filtration Product overview Absolute Filtration

2 Microbiological Safety Cabinet

Designed for user safety, energy savings and environmental protection. an erlab product 04/2013

MODELS. DA, DB and DBM MEDIA B AG D UST/MIST C OLLECTOR. Model DB

Fume Eliminator Family. Mobile and portable high vacuum fume extraction units for occasional and continuous welding applications.

Designed for user safety, energy savings and environmental protection. an erlab product 04/2013

SECURE.GUARD Ultra low temperature freezer

Clean air solutions CAMSAFE 2

92831 TEL: (714) FAX:

Bio Safety Cabinet BS EPC / PRODUCTS / APPLICATION / SOFTWARE / ACCESSORIES / CONSUMABLES / SERVICES. Analytical Technologies Limited

The UK s Leading Ventilation Company. Vent-Axia Pure Air. 1st Edition.

PART 30: LABORATORIES

10 Thorough examination and test

TRS100 Rapid Assay System Pre-Installation Guide

Model FDL 115 Safety drying chambers for limited quantities of solvent

ChemFAST Premium. Hybrid Technology Fume Hood PROTECTION, SAFETY, RELIABILITY. AND MORE.

WELDING FUME EXTRACTION SOLUTIONS BY WELDERS, FOR WELDERS

Blowing in Faster. Protection, safety, reliability. And more.

DIVISION 11 - EQUIPMENT FOOD SERVICE EQUIPMENT LABORATORY FUME HOODS. A. Design Considerations

Innovating Solutions for Staff and Patient Protection. Radiation Shielding

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

Course Specification. Control of Hazardous Substances. Level Foundation Intermediate Advanced Pre-requisites

PRO. Pre-Installation guide. Video. Complete Walkthrough. Scanomat Download Center. Scanomat Connection Diagram. Scanomat Architect Pack (2D/3D Files)

Report on Safe, Appropriate Uses for Filtered Self-Contained Enclosures

Filters & Elements. People. Passion. Performance

Ordering Specifications Esco Hospital Pharmacy Isolator Positive Pressure (HPI-4P_)

Containment Why and How to evaluate

clean air for industry

Purite Water Purification Systems

3M Welding. 3M Adflo Powered Air Respiratory System. Cooler, cleaner. more comfortable. welding

Equipment Specifications Low Voltage. Active Harmonic Filter

Ambient Dust Sampling

EFFICIENT AND SAFE GOODS FLOW FOR COMMERCIAL ENVIRONMENTS

WITH NEUTRODINE TECHNOLOGY

Characteristics Mechanical strength Air leakage Filter by-pass leakage Thermal transmittance Thermal bridge factor

FFU-HE High Efficiency Fan Filter Unit

Emergency Vehicle Exhaust Extraction

The Safety and Sustainability Factors of FILTERED FUME HOODS, DUCTLESS FUME HOODS, AND DUCTED FUME HOODS. By Kenneth Crooks

C-Arm Tables BIODEX. The Clinical Advantage. The table adjusts not you, not the patient. Innovative Contour Design Top

Schools and nurseries. Description of furniture

Line filters LINE FILTERS

Air Purification Fine Dust - HEPA/ULPA Sterionizer - Ion Technology

Ordering Specifications Esco Hospital Pharmacy Isolator Negative Pressure, Recirculating (HPI-4N_)

Power Zone Center. Your solution for power distribution and control systems

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

VFX-1000 Data Sheet and Configuration Guide

THE LEADER IN PERFORMANCE INDOOR AIR QUALITY MEASUREMENTS

Local Exhaust Ventilation

Laboratory Furniture Fume Hood. Turnkey Lab Solution

1.0 Purpose, Applicability, and Scope

xfume Fume Extraction Torch

AIR TREATMENT BREATHING AIR PURIFIERS. DBS Series

SANICON High Performance Metal Detection in Food Products

92831 TEL: (714) FAX:

parker domnick hunter oil-x evolution

SECTION LABORATORY FUME HOODS

Alara-Lukagro. Krijgt alles stil. Cruise ships

AirBench EX Operation and Maintenance

SECTION G3 FUME HOODS

Design and Manufacture of HOT CELLS

AIR QUALITY ENGINEERING M66V HEXAVALENT CHROMIUM TESTING M66V: 2HP with B.I. Blower: with 95% DOP Installed with UPGRADED SEAL JUNE 25, 2011

The Domino DPX. Extraction systems designed for laser coding applications

EE-527: MicroFabrication

Filters & Elements. People. Passion. Performance

Transcription:

CHEMCAP CLEARVIEW Ductless Fume Cabinets & Hoods Operating to recognised worldwide Standards: AFNOR NFX 15-211:2009 BS7989:2001 Energy efficient fan system incorporating Chemcap carbon filtration Chemcap Clearview is ideal for the safety conscious laboratory * COMPREHENSIVE WARRANTY NOW UP TO 5 YEARS * BIGNEAT CONTAINMENT TECHNOLOGY Value. Service. Experience. Tel: +44 (0)23 92 266400 E-mail: info@bigneat.com

Global Leader Bigneat has been manufacturing in the UK since 1972 and is leading the World in containment technology and laboratory safety cabinets. In the past decade Chemcap ductless fume cabinets have been sold to over 70 countries. Chemcap Clearview Ductless Fume Cabinets & Hoods From Model BC 4002 400mm wide To Model BC 1506 1500mm wide Why Chemcap Clearview? Chemcap Clearview cabinets operate with excellent airflow control, highly efficient carbon filtration, are energy efficient and easy to use. View of the working area is an unobstructed all-round 360º and this makes a cabinet comfortable to use for long periods. Chemcap Clearview is a great choice for your laboratory. Leader in carbon filtration technology: Laboratory grade carbon filter media is impregnated with additives to ensure the best possible retention capacities and filtration performance. Bigneat was one of the first companies to replace potentially toxic and carcinogenic inorganic additives with environmentally friendly and biodegradable compounds whilst maintaining excellent performance. Airflows in a Clearview Cabinet Chemcap Clearview the effective way to eliminate airborne laboratory hazards Laboratory air enters the cabinet past the user Airborne contaminants drawn away and into the filter Clean air is returned to the laboratory

Chemcap Clearview TM Fan filter housing Internal lighting Hinged and lockable front doors can be fully opened for access Locks Average air velocity at face 0.5 m/s Included PVC base tray Opening style teardrop Description and Technical Information Keypad controls Particulate filter or spacer Chemcap carbon filter Utilities port 8mm thick cast acrylic panels Key Features Keypad control panel with touch button controls and service due indicator Audible electronic low airflow alarm Clearview all-round vision Easy clean all materials chemically resistant Energy efficient fan system Energy efficient LED lighting Lockable front access window Pre-filter can be bagged under negative pressure Quiet operation Optional extras B Rear baffle FSA Electronic filter saturation alarm FHP Heat protection shield for filters SK Services kit - see mobile bench for details ES Top hat exhaust spigot STB Stainless steel base tray upgrade Model Description Dimensions mm Dimensions mm Access Face Fan System Average Power Sound (external wxdxh) (internal wxdxh) Style Velocity Rated Consumption* Level dba BC 4002 Chemcap Clearview 410 x 540 x 900 380 x 495 x 580 Flap 0.5 m/s 52W 42W <50 BC 6003 Ductless Fume Cabinet supplied complete with 600 x 570 x 1145 570 x 520 x 810 Teardrop 0.5 m/s 52W 42W <50 BC 8004 pre-filter, carbon filter of pre-determined 800 x 570 x 1145 770 x 520 x 810 Teardrop 0.5 m/s 52W 45W <50 BC 1004 type and HEPA filter on request. 1000 x 570 x 1145 970 x 520 x 810 Teardrop 0.5 m/s 52W 48W <50 BC 1204 (Single filter stack) 1200 x 570 x 1145 1170 x 520 x 810 Teardrop 0.5 m/s 52W 52W <50 BC 1206 Supplied complete with 2x pre-filters, 2x carbon filters 1200 x 570 x 1145 1170 x 520 x 810 Trapezium 0.5 m/s 104W 80W <55 BC 1506 of pre-determined type and 2x HEPA filters on request. (Double filter stack, double fan system) 1500 x 570 x 1145 1470 x 520 x 810 Trapezium 0.5 m/s 104W 82W <55 Cabinets available for power supply: 230VAC, 50Hz, 3Amp, 1Ø and 120VAC, 60Hz, 3Amp, 1Ø. Alternative front apertures can be requested or specially engineered for access to contained equipment such as a microscope. Power is shown with fan and lighting. Standards for filtration and containment Chemcap Clearview cabinets meet the requirements of all major and recognised Standards worldwide for containment and filtration, for example: British Standard BS 7989:2001 (for filter efficiency and retention capacity) French Standard AFNOR NFX 15-211:2009 - Class 2 (for filter retention capacity) US Standard ASHRAE 110: 1995 12-203 (for containment) Canadian Standard CSA Z316.5 (for containment) See optional extras, rear baffle required Clear all-round vision

Protect your laboratory staff and improve the laboratory environment When you want to contain and remove hazardous fumes, vapours and/or particulates in your laboratory turn to Chemcap Clearview. SAFETy FirST: Ductless Fume Cabinets offer protection to laboratory staff when undergoing experimentation, testing or hazardous procedures that release fumes, aerosols, particles or vapours. Hazardous compounds are retained in a chemical filter and particulate HEPA filter (option) and clean air is returned back to the laboratory. An operating Chemcap cabinet will remove odours and purify air within the laboratory. It freshens up the environment, making it a safer, more pleasant place to work and improves the wellbeing of laboratory personnel. EnErgy SAving: The majority of the electricity consumed by a ductless fume cabinet is by the fan, which creates the airflow. Conventional fume cupboards draw air-conditioned air out of the room and it is ducted away. Whenever possible use your ductless Chemcap cabinet which saves the cost of heating or cooling replacement air for your laboratory. ConvEniEnT: An important feature of Chemcap cabinets is their portability; they can be moved easily to wherever laboratory procedures are to be undertaken. Less walking less risk. ENVIRONMENTAL STATEMENT: Chemcap Cabinets are kind to the environment Long lasting construction and low environmental impact at installation. Eliminates the release of hazardous emissions into the environment. Reduces your CO2 footprint energy consumption (comparing ducted vs ductless). Optional Bench For your cabinet to be freestanding, select an open bench or cupboard unit either static or mobile. A variable height bench with motorised adjustable legs, mobile or static, is available on request. Technical Information Size MT MTC MTA * Dimensions mm mm (external wxdxh) 600 Bench, robust steel Bench, pressed mild Bench, robust 600 x 570 x 860 box section steel, epoxy coated, construction, epoxy 800 construction, epoxy with cupboard doors coated, 4-leg frame, 800 x 570 x 860 1000 coated, with foot rest (magnetic catches). with motorized bar. Available with height adjustment. 1000 x 570 x 860 1200 Available with levelling feet or Available with levelling feet or lockable castors. levelling feet or 1200 x 570 x 860 1500 lockable castors. lockable castors. 1500 x 570 x 860 * Available for 1000 and 1200 mm cabinets {maximum combined weight of cabinet/hood and enclosed equipment cannot exceed 180kgs} Bench Option SK - Services Kit, mobile bench or stand to be supplied with swan neck water tap with drip cup, gas tap and electrical socket. The gas and water supply hoses are fitted with quick release couplings.

Cabinet Filtration Technology Carbon filtration for chemical fumes and vapours. Highly efficient Chemcap filters eliminate toxic substances and compounds within the recommended occupational exposure limit for pollutant gases having molecular weight equal to or greater than 30. Efficiency is 99.9% for the duration of the filter life with no deterioration in filter performance. Particulate filtration for aerosols and particulates. Pre-filters fulfil the need to arrest larger particles and are fitted to all Chemcap Clearview cabinets, HEPA filtration is fitted as an option when aerosols and small particles require removal. This can be upgraded to ULPA filtration when nanoparticle removal is required. Two or three-stage filtration is used in a Chemcap Clearview cabinet spacer Chemcap carbon filter pre-filter 2-stage filtration Choosing your optimised Chemcap filtration Bigneat offers a multi-purpose (universal) filter which should be selected when a fume cabinet is to be used for a variety of different procedures and handlings. For best performance Bigneat s chemist recommends choosing an optimised filter which will give the best retention and a long filter life. Filter selection Filters OS and H + are suitable for most organic vapours and acid handlings. However we recommend when: 3-stage filtration HEPA or ULPA particulate filter Chemcap carbon filter pre-filter Composition of Filter Type Filter Type Vapours handled 2-stage 3-stage without for chemicals with particulates particulates (HEPA) Filtration used in Chemcap Clearview cabinets Pre-filtration; eliminates particles at 5.0µm or larger to an efficiency of 93% as defined in BS EN ISO 779. Carbon Filtration; filtration efficiency of 99.9%, meets BS 7989:2001 Standard. OPTIONAL PARTICULATE FILTRATION HEPA filtration; (H14 Standard) eliminates particles 0.3µm or larger to an efficiency of 99.995%. Filter system feature A key feature of Bigneat s filter system is the negative pressure produced by the fan which is a necessity for filtration. Any by-pass of the filter system will cause the alarm to sound. Free Assessment Service Please contact us for a free assessment and our chemist will undertake a risk analysis and suggest the best filter for your purposes. Download an assessment form at www.bigneat.com/filtration Organic compounds ORGANIC VAPOURS Filter OS Filter OS HP predominate secondary acids Acid compounds predominate ACID VAPOURS Filter H + Filter H + HP secondary organic vapours Formaldehyde predominates FORMALDEHYDE Filter F Filter F HP Ammonia predominates AMMONIA Filter AM Filter AM HP Radioactive particles RADIOACTIVE IODINE Filter Ri HP are present Mercury is present MERCURY Filter Hg HP Uses are varied MULTIPURPOSE (Universal) Filter MP Filter MP HP To check out which filter is best for your applications please download a Chemcap Filter Chemical Activity and Retention Listing Datasheet at: www.bigneat.com/filtration.

Chemcap Pro2 Pro2 cabinets operate exactly as Clearview however they have a back-up Chemcap filter. These cabinets are particularly suited for laboratories where uses change often such as in universities and for more toxic compounds where breakthrough into the laboratory would be hazardous. When the lower primary filter reaches saturation and fumes breakthrough they will be retained by the upper back-up filter. An inter-filter saturation alarm monitors the primary filter status and alarms upon breakthrough. The cabinet can continue to be used while waiting for replacement filters. Chemcap Pro2 has a safe-change pre-filter system and HEPA filtration is an option. More about Bigneat Bigneat has been designing, manufacturing and maintaining just about every conceivable style of clean air safety cabinet for more than 35 years. Bigneat has grown from a national business to become a company with links worldwide and now enjoys an unrivalled reputation as the world s most innovative supplier in this specialist sector. In addition to Chemcap Ductless Fume Cabinets, Bigneat manufactures fume cupboards, fume & dust arm extraction systems, biological safety cabinets, chemical storage systems, controlled environment enclosures & gloveboxes, laminar flow cabinets, PCR workstations, powder weighing cabinets and robotics & laboratory automation enclosures. Bespoke and custom-built cabinets & hoods We can design and manufacture to your specification, any cabinet or hood whether you need to enclose laboratory automation or apparatus, we can also adapt any of our cabinets to suit your needs. Call us to discuss. Worldwide Representation Your Safety is Our Priority Warranty Bigneat provides 24 months Comprehensive warranty* on its products, extendable to 5 years when combined with Bigneat s Service Contract, or an equivalent from an approved partner. *T&Cs apply, consumables not included. Simple ordering process: STEP 1 Choose cabinet size and which options you would like. STEP 2 Decide on the filter optimisation you require and whether you need particulate filtration. STEP 3 Call us and ask for an instant Quote. Quality Assured Bigneat is accredited to BS EN ISO 9001 Bigneat systems are CE marked QA doc 200 rev1 Scan to watch a 30 second commercial of Bigneat s products. Bigneat Limited 4 & 5 Piper s Wood Industrial Park, Waterberry Drive, Waterlooville, Hampshire PO7 7XU UK Tel: +44 (0)23 92 266400 Fax: +44 (0)23 92 263373 E-mail: info@bigneat.com BIGNEAT CONTAINMENT TECHNOLOGY Value. Service. Experience. Chemcap Clearview is a trade mark 2017 Bigneat Limited. www.bigneat.com