SEISMIC CEILING SUSPENSION

Similar documents
Seismic Ceiling Suspension Guide

Seismic Suspension System Solutions

Current Seismic Code Development and Adoption

CEILING SYSTEMS. What You Need to Know The Basics NEW Armstrong Seismic Rx A Code-Compliant Solution

General applications. Fast. Easy. Customer Focused.

Suspension Systems for Acoustical Lay-in Ceilings Seismic Design Categories D, E & F

WHAT YOU NEED TO KNOW

1. anticipated ground motion 2. type of soil in a specific geographic area 3. seismic use group designation

Specifying Seismic. Ensuring security for suspended systems. Increasingly, building design and implementation teams assume

Technical Services Information Bureau

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Seismic Installation FAQ

Ceiling System Performance One Manufacturer s Perspective. Paul Hough Armstrong World Industries, Inc.

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

Seismic Technical Guide

Seismic Technical Guide

METALWorkS. RH200 Custom Hook-on Panels. General Installation Instructions. Ceiling 1.0 GENERAL Site Conditions Product Description

METALWORKS RH215 Faceted Custom Hook-on Panels

PERIMETER TRIM. Infinity PRODUCT GUIDE. USA and Canada: / fax: Infinity Perimeter Trim 1

Available at: Last Modified: December 2012

Suspension System Data Center Ceiling Solutions

Installation Guide December 2012

Available at: Last Modified: December 2012

PRELUDE. 24 MAX TM Suspension System Data Centre Ceiling Solutions. Assembly and Installation Instructions

SUSPENSION REQUIREMENTS SEE DETAIL B1.2 TYPICAL SYSTEM SECTION SEE DETAIL 'A' THIS SHEET 2" MODULE. SPECIFICATIONS (unless noted otherwise)

Infinity Perimeter Trim

technicalnote Seismic Category D, E, F Installation Details Fully Concealed Rockfon CDX FIELD INSTALLATION Grid

Rockfon Concealed Acoustical Ceiling Systems (CDX) for Seismic Category D, E, F Applications

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS SECTION: ACOUSTICAL CEILING SUSPENSION ASSEMBLIES REPORT HOLDER:

THIS SECTION IS BASED ON ROCKFON S SPANAIR HOOKON METAL CEILING PLANKS.

4 " " SEE DETAIL B1.2. SPECIFICATIONS (unless noted otherwise)

ShortSpan Brochure1 6/14/05 4:39 PM Page 1 CEILING SYSTEMS

Seismic Technical Guide

SECTION ACOUSTICAL PANEL CEILINGS

Seismic Installations and Armstrong Ceiling Systems

METAL SUSPENSION SYSTEMS FOR LAY-IN PANEL CEILINGS: 2001 CBC IR

SECTION NON-STRUCTURAL SEISMIC DESIGN CRITERIA PART 1 - GENERAL 1.1 RELATED DOCUMENTS

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE SNAP-IN METAL CEILING PANELS.

Basic Suspension Systems

The Design of the Suspended T-bar Ceilings in accordance with AS for the New Royal Adelaide Hospital

AXIOM Building Perimeter System Assembly and Installation Instructions

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

THIS SECTION IS BASED ON ROCKFON S PLANOSTILE D LAY-IN METAL CEILING PANELS.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

THIS SECTION IS BASED ON ROCKFON S TRADITIONS METAL CEILING PANELS.

SECTION NON-STRUCTURAL METAL FRAMING

SECTION GYPSUM BOARD ASSEMBLIES

SECTION (09512) - ACOUSTICAL TILE CEILINGS

MORE INFORMATION BPLA

METALWORKS Blades Classics

PLANK AND LARGE PANEL STABILIZER BARS APPLICATION GUIDE

OPTIMA Vector Plank Installation Instructions

SECTION DRYWALL GRID LINEAR LIGHTING INTEGRATION

A. Product Data: Submit manufacturer's descriptive literature, and recommendations and instructions for installation.

Available at: Last Modified: December 2012

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION SEISMIC CONTROL OSHPD

AXIOM Direct Light Coves Assembly and Installation Instructions

THIS SECTION IS BASED ON ROCKFON S CURVGRID ONE-DIRECTIONAL CURVED METAL CEILING PANELS.

Union County Vocational - Technical Schools Scotch Plains, New Jersey

Store No MAY 13 Addendum No. 1 SECTION ACOUSTICAL PANEL CEILINGS

Optima Vector Plank. Installation Instructions. Ceiling

DIVISION 5 METALS SECTION COLD-FORMED METAL FRAMING

A. This Section includes acoustical panel ceilings installed with exposed suspension systems.

SECTION COMPOSITE CORE ACOUSTICAL PANEL CEILINGS. Sound-Rite Inc. #9, rd Avenue NE Calgary, AB T2A 7P3

USG Exterior Ceiling Applications. Systems Guide 2014

METALWORKS Blades Classics

INSTALLATION GUIDELINES FOR SEISMIC APPLICATIONS

METALWORKS Torsion Spring

DIVISION: FINISHES SECTION: SUSPENSION SYSTEMS REPORT HOLDER: WORTHINGTON ARMSTRONG VENTURE (WAVE)

6" MAX CARRIER OVERHANG, TYP. MAX CARRIER SPACING VARIES DEPENDING ON DESIGN WIND PRESSURE, SEE DETAIL B1.2, TYP.

References in blue are general indicators to the specifier. If not used it can be deleted, but may be needed in the future.

OPTIMA Concealed. Installation and Maintenance Guide

Student Services & Classroom Addition

Seismic performance of suspended ceilings: Critical review of current design practice

System S 3 cliq. Exposed, seismic resistant. OWAlifetime collection

LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

DETAIL INSTRUCTION No. 1

SPECIFICATIONS (unless noted otherwise)

RULON LINEAR OPEN SUSPENDED WOOD CEILING SYSTEMS ARCHITECTURAL SPECIFICATIONS

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SECTION ACOUSTICAL CEILING SYSTEMS

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

1. Acoustical panels. 2. Exposed suspension systems for ceilings. 3. Wire hangers, fasteners, main runners, cross tees, and wall angle moldings.

Construction Standards PAGE

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

d u o installation guide duo Exposed Grid Ceiling System

EXTERIOR PLANK SERIES SPECIFICATION DATA

Union County Vocational - Technical Schools Scotch Plains, New Jersey

KINETICS Pipe & Duct Seismic Application Manual

OPTIMA and LYRA Concealed

SECTION VIBRATION AND SEISMIC CONTROLS FOR ELECTRICAL SYSTEMS

USG Interiors, LLC Plant # Crocker Rd. Westlake, OH 44145

A. This Section includes ceilings consisting of acoustical panels and exposed suspension systems.

Code Compliance Meets the requirements for suspended ceilings in accordance with the 2012 International Building Code.

EuroStone / EuroStone. sustainable ceiling panels. chicagometallic.com 1

Make Waves. Topo 3-Dimensional System

Rockfon Concealed Acoustical Ceiling Systems (CDX and SCD)

AXIOM Indirect Field Light Coves

ATI Evaluation Service A Division of Architectural Testing Certification Services PCA-125

Transcription:

Better. Faster. Easier. Reliable. Efficient. Compliant. SEISMIC CEILING SUSPENSION Fast. Easy. Customer Focused.

Seismic Codes: Development and Adoption Purpose of Installation Requirements for Suspended Ceilings Suspension systems strong enough to resist lateral force imposed upon it without failing. Prevent border panels from falling from the ceiling plane. Federal Emergency Management Agency (FEMA) Seismic performance during recent large California earthquakes prompted FEMA to address several concerns including suspended ceiling performance during a seismic event. Research and tests demonstrated that current industry seismic standards (UBC Standard 25-2) were not adequate. FEMA determined that the key to good seismic performance was support of individual panels at walls and expansion joints and interaction with sprinkler systems. Source: FEMA 368 NEHRP Recommended Provisions for Seismic Regulations for New Buildings and Other Structures New Seismic Categories According to the International Building Code, a Seismic Design Category must be established for each construction project based on: 1. Anticipated ground motion 2. Type of soil in a specific geographic area 3. Occupancy category The Code Official is the Only Authority to Enforce Code Compliance The building code was established to set minimum requirements for life safety and preservation of property. It is important to know that while the building code establishes the requirements, it is the code official that has the power to enforce its provisions. The code official also has the latitude to allow materials and methods of construction that are not addressed in the code. In this case, an official can perform their own analysis of evidence presented or can rely on independent, qualified sources such as ICC-ES to do the analysis and provide their findings. The resulting report is specific, technical evidence on which the code official can base approval of a particular design without delaying construction. Earthquakes Are Coming! California 62% probability of at least one magnitude 6.7 or greater quake in the San Francisco Bay region before 2032. All 50 states and the Virgin Islands use the International Building Code (IBC) at a local or state wide level. East Coast & Midwest 90% probability of a magnitude 6 to 7 event occuring within the next 50 years. p2 I 800.323.7164 I chicagometallic.com

Industry Standard Construction ASCE 7-05 Section 13.5.6.2.1 Seismic Design Category C Reference CISCA Recommendations for Seismic Zones 0-2 The ceiling must be a free-floating system, not attached at any walls. Main and Cross Tees need a minimum of 3/8) clearance from the walls. All perimeter grid components must be tied together to prevent spreading using Spacer Bars, or other means. Must use Safety Wires on light fixtures. Perimeter Support Wires required if Wall Angle support ledge is less than 7/8). Intermediate Duty system, 60 lb. minimum connection strength. Use of hook Cross Tee connection is acceptable. Refer to IBC 2006, ASCE 7-05 and CISCA Seismic Zones 0 & 2 for complete details. ASCE 7-05 Section 13.5.6.2.2 Seismic Design Categories D thru F Reference CISCA Recommendations for Seismic Zones 3 & 4 Ceiling areas less than 144 ft 2 are exempt of standard construction requirements. Heavy Duty suspension system must be used. All system connections need to withstand a minimum connection strength of 180 lbs. A Wall Angle with a 2) ledge support must be used at the perimeter. Ceiling must be attached on two adjacent walls. The opposing walls must be unattached, with a 3/4) clearance from the wall for the Main or Cross Tees. Spacer Bars, or other means, must be used to tie perimeter components together on unattached walls to prevent spreading. Perimeter Wires must be used within 8) from the wall on all four walls. Safety Wires must be attached to the light fixtures. Light Fixtures must be positively attached to the grid system. Ceiling penetrations, like sprinklers, must provide clearance for movement. Ceiling areas larger than 1,000 ft 2 require horizontal restraint every 144 ft 2 consisting of four diagonal Splay Wires or rigid braces in combination with a Compression Post. Ceiling areas larger than 2,500 ft 2 require a Seismic Separation Joint. Ceilings subject to special inspection per ASCE 7-05 Section 13.5.6.2.2 (h). Refer to IBC 2006, ASCE 7-05 and CISCA Seismic Zones 3 & 4 for complete details. chicagometallic.com I 800.323.7164 I p3

Seismic Ceiling Installation: FAQ Can I use any CMC grid in seismic applications? Because ceiling panel performance and non-tee bar suspension systems are not well defined in the IBC requirements, CMC is working with an independent, internationally renowned structural engineering firm to test both standard and non-standard ceiling systems for seismic performance. The results of our full-scale seismic tests offer proven safety and performance support for standard and non-standard ceilings, flexible design options, and more efficient installation designs. The following CMC grid systems are acceptable for use in International Building Code Seismic Design Categories: 200 Snap-Grid / 640, 650, 660 & 670 Drywall / 660 Wide Face / 730 All Stainless Steel / 830 All Aluminum / 1200 Seismic / 1260 Aluminum Cap / 4500 & 4600 Bolt Slot / 4000 Tempra Contact Chicago Metallic for specific components and corresponding Seismic Design Categories. Note: Check local code for installation requirements. Where can I find the information I need to install ceilings to meet seismic requirements? You will first need to verify the seismic design category for the building in which you will be installing your ceiling. This information will be determined by the architect or designer on record, and can be found in the general information section of the specifications or in the general notes on the structural drawings. You will then want to refer to the building code and installation standards that are currently being used or accepted in your jurisdiction, and are available from your local code official. What is a seismic design category? A Seismic Design Category (SDC) is a classification assigned to a structure based on its occupancy or use (Occupancy Category) and on the level of expected soil modified seismic ground motion. This can be expressed schematically as follows: [Occupancy Category] + [Soil modified seismic ground motion] SDC Seismic Design Category (SDC) A B C D E and F What does it mean? Very small seismic vulnerability Low to moderate seismic vulnerability Moderate seismic vulnerability High seismic vulnerability Very high seismic vulnerability and near a major fault Where can I find instructions detailing each step needed to install ceilings that meet seismic design categories? Generally accepted installation standards are based on current versions of the IBC, ASCE-7, the CISCA Seismic documents, and the ASTM E 580, and are straightforward. If you need additional assistance, please feel free to contact our Technical Services team at 800-323-7164, option 3. How can I verify what codes my local or state officials require us to follow? Each local or state government office has a department that manages building permits and construction requirements. You should contact them to see what installation standards they will require. p4 I 800.323.7164 I chicagometallic.com

Seismic Ceiling Installation: FAQ My building owner does not like the 2) wall molding that is required in IBC seismic design categories D, E and F. Is there an alternative? How can local code officials be sure that the use of the Chicago Metallic perimeter clip 1496.00 is compliant with the IBC? Chicago Metallic has designed a seismic perimeter clip, item # 1496.00, which provides for the use of a 15/16) wall angle while eliminating the need for perimeter spacer bars. This clip has been recognized by ICC-ES as an alternative installation that is compliant with the IBC. Official approval of this alternative remains the purview of the Authority Having Jurisdiction (AHJ). See ICC-ES ESR-2282 at www.icc-es.org. Chicago Metallic s seismic grid system, including the 1496.00 perimeter clip, was rigorously tested at the Structural Engineering Earthquake Simulation Laboratory (SEESL) at the State University of New York at Buffalo. The evaluation process, including room size testing on shake tables at the University were monitored by engineers from Chicago Metallic and the State University of New York at Buffalo, as well as by engineers from an independent structural engineering group, to insure accurate data was properly collected and summarized. This report was then submitted to ICC-ES, where our suspended ceiling grid and perimeter clip has been recognized by ICC-ES to perform as required by the current IBC. Where can the local code officials or I find verification of the testing, or recognition by ICC-ES? Our evaluation report (ICC-ESR 2282) from ICC-ES can be found on their website at www.icc-es.org. The evaluation report can be found under the search function on the website, by entering either our manufacturers name (Chicago Metallic), or our ICC-ES report number (2282). The report will provide in detail the evaluation of our product and proper installation requirements. There is also a link to the report directly from the Chicago Metallic web site. Has an alternative method for seismic separation joints been developed yet? Chicago Metallic has designed what we believe is the only seismic separation joint alternative that has been both tested at the State University of New York at Buffalo and evaluated by an independent, internationally-renowned structural engineering group. The Seismic Separation Tee (SST) from Chicago Metallic has been designed to provide movement due to seismic activity along the separation joint. Seismic activity causes the SST tees to move linearly, thus eliminating the need for a conventional separation joint. Other benefits over competitive products or standard recommended installations include: a one-step installation process Just insert the tees and install push rivets to create the expansion joint, and you are done. There is no going back to cut main or cross tees or to add additional channels, angles or clips. Is there written documentation for the SST too? Our independent structural engineering group has written a summary report that shows that our SST performs in such a way that meets the requirements outlined by the IBC. This report can be delivered directly to the code official by contacting Chicago Metallic and providing us with the code officials contact information (name, address) along with the project name and location. chicagometallic.com I 800.323.7164 I p5

Seismic Ceiling System Details Though suspended ceilings are considered non-structural, recommendations for seismic stabilization do exist. However, traditional seismic ceiling construction is costly. Additional joint clips, wires, stabilizer bars, and seismic separation joints increase the cost of materials, while attaching separator clips and field cutting cross tees significantly impact labor costs. In addition to its Seismic 1200 Intermediate and Heavy Duty grid, Chicago Metallic now introduces the Seismic Separation Cross Tee (SST ) and Perimeter Clip, both of which can save up to 75% in material and labor costs compared to traditional installation methods. Seismic 1200 Exposed Grid 15/16) Wall Angle Chicago Metallic s Exposed Tee grid includes seismic and fire-rated seismic constructions. The 1200 System is offered for Intermediate Duty and Heavy Duty performance per ASTM C 635 to satisfy the requirements of all Seismic code constructions. The exposed tee construction permits direct upward access to mechanical systems and is a cost-effective solution to seismic requirements. Stab-in cross tees cantilever during installation and will not fall out, making for an easier installation and protecting against lateral pull-out. When used with the Seismic Separation Tee, the 15/16) wide face creates a sleek ceiling design in all seismic installations. 1496 Seismic Perimeter Clip SST Cross Tees Stab-in cross tees with QuickClick end clips. SST Cross Tee eliminates the three-step process of competitive alternatives. The 1496 Seismic Perimeter Clip exceeds the IBC requirement for 2 ledge support. 1496 Seismic Perimeter Clip Back Plate 3/8) and 3/4) dimension markers The following CMC systems grid are acceptable for use in International Building Code Seismic Design Categories: 1200 Seismic 1260 Aluminum Cap 660 Wide Face 4000 Tempra 4500 Ultraline 4600 Ultraline Contact Chicago Metallic for specific components and corresponding Seismic Design Categories. Note: Check local code for installation requirements. p6 I 800.323.7164 I chicagometallic.com Tee Attachment Screw Holes Each seismic design category has specific requirements regarding perimeter components, and our 1496 Seismic Perimeter Clip has been engineered to meet them. Current code requirements include a 2) wide perimeter wall molding, and stabilizer bars to provide support, and prevent the ceiling grid from spreading apart along the molding. Chicago Metallic s Seismic Perimeter Clip meets seismic criteria set forth by the International Building Code (IBC) to stabilize main and cross tees at the ceiling s perimeter, as detailed in ICC-ES Report # 2282. This clip ties together perimeter components and has been tested and recognized as an alternate method of stabilizing tees at the perimeter. Its robust construction allows contractors to use a sleek 15/16) angle in lieu of the less desirable 2) angle and eliminates costly stabilizer bars. The Perimeter Clip is easy to install. Clearly visible dimension markers on the clip show the required 3/8) or 3/4) clearance of the grid to the wall. An integral back plate accommodates the additional attachment of the clip to the wall and/or wall angle if desired, and screw holes provide easy attachment to the tee when necessary. The clip is a bright brass color, making it easily identifiable during on-site inspections. The commercial quality steel clip fits common grid components and can be used with lay-in panel ceilings.

Seismic Ceiling System Details SST (Seismic Separation Tee) elongated integral end tab designated seismic joint main tee staked-on stab-in end tab The Chicago Metallic SST is the only product available in the market today that has been both tested at the State University of Buffalo and reviewed by an independent, internationally renowned structural engineering group to be a viable solution for creating seismic separation joints in IBC seismic design categories D, E and F installations. Chicago Metallic s SST Seismic Separation Tee offers a ONEstep process to meeting IBC requirements. Each tee has one staked-on stab-in end tab and an opposing elongated integral end. The elongated ends of two SSTs are installed on both sides of the Main Tee that has been designated as the Seismic Joint, then locked in place with two (2) push rivets. In a seismic event, seismic forces cause the tees to move linearly, thus eliminating the need for a conventional separation joint (see photos below). In addition to the labor saved by going from the THREE-step process of returning to the assembled grid, cutting off tee clips, and installing two-piece brackets, the ONE-step SST process eliminates the need for more channels, wall angles, and additional hanger wires; does not interfere with struts, wires, push rivets lock each SST in place or ceiling panels; helps keep the grid system square, and preserves the appearance of the gridwork. The extended integral tab of the SST allows it to push towards and pull away from the designated seismic joint main tee and maintain a strong connection. The push rivets enable the joint to withstand a pullout force in excess of 180 pounds. The internal friction in the joint also provides a measure of damping. > > > > PUSH TOWARDS < < < < < < < < PULL AWAY > > > > Conventional Seismic Separation Joint To install suspended ceilings that exceed 2,500 sq. ft. in seismic zones, the IBC requires separation joints that allow cross tees to move laterally during a seismic event. Traditionally, contractors create their own seismic solutions by assembling the grid and then revisiting the assembly to cut the grid and build up conventional separation joints with tees, channels, and angles. The grid is then stabilized with additional hanger wires. In addition to increased material costs and time on the job, this multi-step process risks incurring delays while the construction method is inspected and approved. Competitive alternatives to this method include installing a two-piece bracket at main/cross tee intersections. This solution requires the contractor to install the grid, then return to the grid, cut off the cross tee tabs, and attach the bracket with screws. While the system may meet IBC requirements, it is a THREE-step component and labor intensive process. chicagometallic.com I 800.323.7164 I p7

IBC Seismic Catagory C Conventional IBC Installation CMC 1496 Clip Installation (ESR-2282) A-1 > < A-2 B-1 > < B-2 A-1 B-1 3/8) Min. 3/8) 1496 Clip 15/16) Angle 7/8) Min. Spacer Bar A-2 B-2 3/8) 3/8) Min. Spacer Bar 7/8) Min. 1496 Clip 15/16) Angle * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) Spacer Bar p8 I 800.323.7164 I chicagometallic.com

IBC Seismic Catagories D, E and F Conventional IBC Installation ATTACHED WALL CMC 1496 Clip Installation (ESR-2282) ATTACHED WALL D-1 or C-1 > < C-2 D-2 > < D-3 ATTACHED WALL ATTACHED WALL 6( max. 6( max. 6( max. 6( max. C-1 Perimeter Wire (use this option or D-2 below) ± 10 from vertical Perimeter Wire ± 10 from vertical 8) Max. D-1 8) Max. 2) Min. C-2 Perimeter Wire ± 10 from vertical Pop Rivet D-2 Pop Rivet (use this option or D-1 above) Pop Rivet Perimeter Wire ± 10 from vertical 15/16) Angle 8) Max. 3/4) 8) Max. 1496 Clip Spacer Bar 2) Min. Screw Screw 15/16) Angle D-3 Perimeter Wire ± 10 from vertical 3/4) from grid to inside of angle * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) Spacer Bar 1496 Clip 8) Max. 15/16) Angle chicagometallic.com I 800.323.7164 I p9

Seismic Separation Joint IBC Seismic Catagories D, E and F Conventional IBC Installation CMC SST Installation E > < F 12( O.C. 6( O.C. max 6( O.C. max Seismic Joint SST rows to either side of designated seismic joint E F 1428 Angle Designated Seismic Separation Push Rivets 1-1/2) 1448 Channel 1448 Channel SST Elongated Integral Ends IMPORTANT! Do not place horizontal restraint over separation joint. * LEGEND 12 ga. hanger wire Horizontal Restraint (Refer to illustration on page 11) SST p10 I 800.323.7164 I chicagometallic.com

Seismic Horizontal Restraint 12 ga. hanger wire typical 4( O.C. Vertical Post 12 ga. brace wires connected to Main Tee 45 max 45 max 45 max 45 max These horizontal restraint points shall be placed in both directions with the first point within 6( of each wall. Brace Wires shall be attached to Main Tees within 2) of Cross Tee intersection, at a maximum angle of 45 relative to ceiling plane. Wires shall be tied with a minimum of three tight wraps (see ASTM C 636 for examples). For complete details, please refer to the current version of ASCE 7. Vertical Struts Allowable Lengths Maximum Recommended Length for Vertical Struts 1 EMT Conduit 1/2) EMT...up to 5(10) 3/4) EMT...up to 7(8) 1) EMT...up to 9(9) Metal Studs Single 1-5/8) metal stud (20 gauge)... up to 12(0) Single 2-1/2) metal stud (20 gauge)... up to 13(6) Back-to-back 1-5/8) metal stud (20 gauge)... up to 15(0) Back-to-back 2-1/2) metal stud (25 gauge)... up to 15(0) Note: Plenum areas greater than 15(0) will require engineering calculations. 1 Source: Northwest Wall & Ceiling Bureau Rev. 4/07 chicagometallic.com I 800.323.7164 I p11

Chicago Metallic Ceiling Products Metal Perimeter Trim/ Curvilinear / Flat Metal Panel / Embossed Metal Panel / Linear / Open Plenum / Security Panel Premium / Utility / Controlled Environment Grid General Applications / Special Applications / Drywall Applications Ceiling Systems and Specialty Products - USA and Canada: 800.323.7164 / Fax: 800.222.3744 / chicagometallic.com belgium / denmark / uk / germany / france / hong kong / prc / malaysia / united arab emirates / mexico Chicago Metallic and its logo are Registered Trademarks of Chicago Metallic Corporation. Ultraline, Tempra, QuickClick and SST are trademarks of Chicago Metallic Corporation. 2011 Chicago Metallic Corporation All Rights Reserved Printed in USA SNL0027A1411 Literature Disclaimer: Presentations in this brochure or any other Chicago Metallic Corporation publication are correct to the best of our knowledge at time of preparation. We provide this information in an advisory capacity only. Any advisory recommendations given in our publications must be modified to conform with local codes, conditions and specifications. We reserve all rights to amend any information published in our literature without additional notice. Chicago Metallic can not be held responsible or liable for the selection nor application of our products.