electroplating DC power supply type SIFCO PROCESS POWER PACK 1028

Similar documents
Model S-2200 Single Pocket Currency Discriminator Operating Manual

Magner /35-3 Series Currency Counter. Operator's Manual

Table of contents. 1. Introduction

SABRE P MODEL PD603 PROCESS METER Instruction Manual

SOLCAL. 1 digital regulator. 257 series CONTENTS INSTALLATION AND COMMISSIONING MANUAL. Function

POWER FACTOR REGULATOR. Computer-12e-xx INSTRUCTION MANUAL ( M / 02A ) (c) CIRCUTOR S.A.

FAST POWER FACTOR REGULATOR. Computer-14df - xx - 144a INSTRUCTION MANUAL ( M / 00A ) (c) CIRCUTOR S.A.

Adam Equipment LBH SERIES. (P.N , Revision B2, January 2010)

BA110 Electronic Balance 5000g x 1g. Impact Test Equipment Ltd & User Guide. User Guide

FIXED-WINDOW POWER DEMAND CONTROLLER BY ENERGY PULSES CVM-R8D-CPP INSTRUCTION MANUAL

Powerware 9120 UPS. Date: Issued By: Product Affected May 27, 2003 Gary Bankay PowerFlex 7000 MV Drive

SABRE T MODEL PD743 TEMPERATURE METER Instruction Manual

S-1600 Series Currency Counter Operating Manual. Models S-1600, S-1615 and S-1625 Including "V" Series

Sabre P Model PD603 Process Meter Instruction Manual

EC Type-Approval Certificate

Solar controller for thermalsophin system SR609C operation manual Contents

High Precision Balances

MTTC User Manual. Innovative Technology for a Connected World. General Description. Specifications and features

FITTING AND CONNECTION OF CENTRAL UNIT EEN-CIC12

Daker DK kva. Parallel installation quick start. Part. LE08927AA-09/15-01 GF

Inscale Measurement Technology Ltd Tel: Fax:

User Manual. XK315A1 water proof series Weighing Indicators. Applications: Electronic platform scale, weighing scale, etc.

MICRO-COMPUTER BASED 2-CH DIGITAL INDICATING CONTROLLER/DATA LOGGER LCD-13A INSTRUCTION MANUAL

Solar Eye User Manual

Manual. AGRETO Hydraulic Scale AGRETO electronics GmbH

VWR B-Series Balances Operation Manual

Weighloader user manual. Document reference: V2.01

Adam Equipment LBC SERIES. (P.N , RevisionB1, January 2010)

Imperial Series. Model IMP-425/525/625/825/1000AP IMD-425/525/625/825/1000AP IMP-1025/1200/1500/2000AP IMD-1025/1200/1500/2000AP

Temperonic Hog Sorter Control Unit

Adam Equipment LBC SERIES. (P.N , RevC, August 2011)

Installation & Calibration Manual

LINEARIZER SAAP (DC CURRENT INPUT) LINEARIZER SAVP (DC VOLTAGE INPUT) INSTRUCTION MANUAL

PD662 Loop-Powered Meter Instruction Manual

INSULATION MONITORING RELAIS

Operating Manual. Wärtsilä JOVYTEC L 6kVA 10kVA. BAX 3297_en

MULTIPOINT EARTH LEAKAGE RELAY CBS-8 SERIES USER S MANUAL

EN REAL TIME RECEIVER AND RW INSTALLATION AND USE

User s Guide. Weighing Indicator WIDRA - HF L / HF S 2000/02/11 21:21:58. No. TARE NET GROSS TOTAL

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kva. User Manual.

64C Amplification Block. Instruction Manual

OPERATING INSTRUCTIONS. for the TYPE KATC-C1 AUTOMATIC TRANSFORMER COMPARATOR

PD662 LOOP-POWERED METER Instruction Manual

Operation Manual. Dual Temperature Digital Dry Block Incubator. Catalog No. INCUBATOR Rev C. April 2016

Rook Currency Counter

HOBO Plug Load Logger (UX ) Manual

Version : Date : USER MANUAL METRON 2.2 C, CO, CR, D, S, SL, SU

IDS 1632 Installer Manual K Issued September 2009

Liebert NXL Power-Tie Controls

MODEL ASCS-15 CRANE SCALE

SIO Series RS485 Modbus RTU Remote IO Modules User Manual

Exceed IRELAND Electronic Postage Computing Scale

Moving money forward UV MG

CSG A.L.C. COUNTING SCALE USER MANUAL

BEFORE USING THE COUNTING SCALE

Operator Manual. OHAUS Aviator 7000

Use and Maintenance Manual

CONTENTS. 3-1 Unpacking and Checking Installing Components Leveling the Scale... 1

OPERATION MANUAL. Model : DC-190 TERAOKA SEIKO CO., LTD. Edition Month Year October 1998

Galaxy 300. Operation 05/

Models TJ30K TJ15K TJ6K TJ3K. Resolution Ratio 1g 0.5g 0.2g 0.1g Calibration graduation 10d 10d 10d 10d

EGT-AF08 USER GUIDE WHEEL WEIGHING SYSTEMS WITH VARIOUS PLATFORMS

User Manual. Network Pro Series Tower and Rack-Mount Convertible UPS. Table of Contents 1000/1500/2200/3000

Manual Rotary Heat Sealers. Type: F108TX. List of content : Introduction 2. General description 3. Application 4. Safety precautions 5

Equipment Specifications Low Voltage. Active Harmonic Filter

Quick Reference Guide

Temperature Controllers: JC Series Digital Indicating Controllers. JC Series. High Performance Controllers...at the lowest prices anywhere!

Océ DFS10. Operator Manual

CN Series P.N , Software rev. T 8, Revision A1- July 2014

PD662 LOOP-POWERED METER

Galaxy 300 and Galaxy 300i

1600 Currency counting machines

SUPPLY NETWORK ANALYZER CVM-SP SERIES INSTRUCTION MANUAL ( M / 01A

The power behind competitiveness. Delta UPS - Amplon Family. RT Series, Single Phase 5/ 6/ 10 kva. User Manual.

Model PD656 Large Display Process Meter with Rate/Totalizer/Batch Control Features Instruction Manual

1 HR 550FS Handwheel. 1.1 Handwheels

MS 3801 USER MANUAL. Manufactured by: Charder Electronic Co., Ltd. No.103, Guozhong Rd., Dali Dist., Taichung City 412, Taiwan (R.O.C.

OXYGEN UV+ ABSOLUTE RANGE

EPS 7000 and EPS 8000

HARBORTOUCH ECHO USER GUIDE HARBORTOUCH SUPPORT LINE:

OM-CP-QUADPROCESS 4-Channel Low Level DC Current Data Logger. OM-CP-OCTPROCESS 8-Channel Low Level DC Current Data Logger INSTRUCTION SHEET

HYDROCHLOR. Owners Manual. ! WARNING

CBS-8 SERIES INSTRUCTION MANUAL

Turbofan H10T LMD / H10T RMD

Technical Manual. Section 521 Built-In ACD Supervisor Guide

MPM 100 Monitor Product Description Guide

LOADRITE L2180 User manual. LOADRITE L2180 User Manual 1-1

Operating instructions, TC543 controller.

1993 Specifications CSJ SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

User Manual. Precision Balances XSR models

The power behind competitiveness. Delta UPS - Modulon Family. DPH Series, Three Phase kw. User Manual.

KERN KFB/KFN-TM Version /2010 GB

High Precision Balances. Operation Manual

DATA LOGGER Model DL-SA11

The Biology CRO. Protein Staining System. For electric staining of proteins in mini polyacrylamide gels. Version 1.0 April 3, 2010.

X30 System Components

1993 Specifications CSJ , etc. SPECIAL SPECIFICATION ITEM Digital Loop Carrier System

MERIGAUGE MODEL 3900 OPERATING INSTRUCTIONS

Pressure Booster System. Hya-Eco VP. Type Series Booklet

Delta UPS - Ultron Family. HPH Series, Three Phase 60/80/100/120 kva. User Manual. The power behind competitiveness EPO

Transcription:

Documentation type: Author: Quick start manual J. Schumann Last modification: Last modification by: D. Mayer-Eckardt Print date: 9/9/2010 10:46 AM Last saving: 9/9/2010 10:46 AM Doc-Nr.: ZK-xxxxxx-01-V01 Comment: Quickstart Manual for electroplating DC power supply type SIFCO PROCESS POWER PACK 1028 with integrated pole changer and preset counter with overload protection manual controlling via keypad or RS485 BUS controlling Read this operating manual completely before installation. Not following installation and operation procedures will void the warranty. It also could result in serious injury or death. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 1/17 Streng vertraulich! Keine Weitergabe an Dritte. Alle Rechte liegen bei plating electronic GmbH. Jegliche Änderung nur mit ausdrücklicher Genehmigung der plating electronic GmbH

List of Contents: 1 Conformity assertion of the European community ---------------------------------------- 3 2 Quick Start Manual ------------------------------------------------------------------------------- 4 2.1 Main switch -------------------------------------------------------------------------------------------4 2.2 LCD display -------------------------------------------------------------------------------------------4 2.3 Set output voltage -----------------------------------------------------------------------------------5 2.4 Set output current -----------------------------------------------------------------------------------5 2.5 Select output polarity -------------------------------------------------------------------------------5 2.6 AUTO pole changer mode ------------------------------------------------------------------------6 2.7 Manual start of preset counter, reset -----------------------------------------------------------6 2.8 Setting of the preset counter ---------------------------------------------------------------------6 3 Standard functions: current and voltage regulation -------------------------------------- 7 3.1 Constant current regulation -----------------------------------------------------------------------7 3.2 Constant voltage regulation ----------------------------------------------------------------------7 4 Using the AH Counter --------------------------------------------------------------------------- 8 5 A/H RESET key functions --------------------------------------------------------------------- 10 5.1 Reset ------------------------------------------------------------------------------------------------- 10 5.2 Setting the AH Counter Auto-Start ------------------------------------------------------------ 10 6 General description ----------------------------------------------------------------------------- 11 7 DC-output connection -------------------------------------------------------------------------- 12 8 Mains supply -------------------------------------------------------------------------------------- 12 9 Back plane----------------------------------------------------------------------------------------- 13 10 Key pad functions -------------------------------------------------------------------------------- 14 10.1 The key pads to the right hand side ---------------------------------------------------------- 14 10.1.1 Key ON ------------------------------------------------------------------------------ 14 10.1.2 Key OFF ---------------------------------------------------------------------------- 14 10.1.3 Key Enter -------------------------------------------------------------------------- 14 10.1.4 Key CLR ---------------------------------------------------------------------------- 14 10.2 Second key pad row ------------------------------------------------------------------------------ 15 10.2.1 Key increase voltage ------------------------------------------------------------ 15 10.2.2 Key decrease voltage ----------------------------------------------------------- 15 10.2.3 Key increase current ------------------------------------------------------------ 15 10.2.4 Key decrease current ----------------------------------------------------------- 15 10.3 The key pads to the left hand side ------------------------------------------------------------ 16 10.3.1 Key +/- Manual pole changing ------------------------------------------------ 16 10.3.2 Key AUTO, AUTO pole changer mode ------------------------------------- 16 10.3.3 Key A/H RESET, manual start of preset counter, and reset -------- 16 10.3.4 Key F4, direct setting of the preset value ---------------------------------- 16 10.4 Short circuit detection (overload function) -------------------------------------------------- 17 11 Warranty and Repair Information ------------------------------------------------------------ 17 SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 2/17

1 Conformity assertion of the European community Conformity assertion of the European community corresponding to the EMVguidelines 2004/108/EG about the electromagnetic compatibility and the lowvoltage guidelines 2006/95/EG We Manufacturer: plating electronic GmbH Ust.-Id No.: DE 141938869 Address: Marie-Curie-Straße 6 79211 Denzlingen / Deutschland declare that our product Installation: Serial No.: electroplating DC power supply type SIFCO PROCESS POWER PACK 1028 air cooled, with integrated pole changer with preset counter, with RS485-BUS interface see rating plate Customer: Hendor / SIFCO pe-no.: on which the declaration is related to, is corresponding to the following norms and standards resp. normative documents: DIN EN 61000-6-4 :2007 DIN EN 61000-6-2 :2005 DIN EN 55011 :2010 (class A, group 1) DIN EN 50178 :1998 Denzlingen 2010-06-01 in order: J. Schumann SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 3/17

2 Quick Start Manual 2.1 Main switch Switch main switch on. The switch lights up. 2.2 LCD display In normal operating mode the digital display shows the actual current and voltage parameters of the DC power supply. In the third line the Ah count is shown. Corresponding to the selected operating mode the display can show the parameters of additional functions The display can also show error messages. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 4/17

2.3 Set output voltage VI A Use the Voltage Up key or Voltage Down key to adjust the output voltage. VI A The LED in keypad Voltage Up constant voltage mode. UV V lights up if the unit works in Constant voltage is the normal mode for brush plating and is the default setting for your power pack! 2.4 Set output current Use the Current Up key or Current Down key to adjust the output current The LED in keypad Current Up constant current mode. AI A lights up if the unit works in Constant current is the normal mode for brush anodizing! If you would like to set this unit to operate in constant current mode, follow the instructions below, item Constant current regulation. 2.5 Select output polarity In the manual operating mode, (which is the default setting for this unit) +/- F1 To operate in forward polarity the +/- key must be switched off (the red LED will be OFF). +/- F1 To operate in reverse polarity the +/- key must be switched on (the red LED will be ON). SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 5/17

2.6 AUTO pole changer mode AUTO F2 The pole changing is done by programmed timing for cathodic and anodic position. Press ON key to start the AUTO pole changing *) The LED is used to indicate the AUTO mode. *) You can select the start polarity for the automatic pole changing by pressing the +/- key while AUTO key is on and the LED in Off key lights up (DC output off). 2.7 Manual start of preset counter, reset A/H RESET The A/H RESET key is used to start the preset counter manually (or to enable auto-start) if the plating process is running. If you want to reset the actual count of the preset counter press the A/H RESET key. If the LED lights up the preset counter is enabled (auto start released). 2.8 Setting of the preset counter F4 The F4 key is used to set the Ah count preset value directly. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 6/17

3 Standard functions: current and voltage regulation Setting of the output voltage and output current in standard operating mode. 3.1 Constant current regulation UV V If a constant current is needed, follow these terms: First move the output voltage to the highest admitted level for your process by using the Voltage Up or Voltage Down key. Now use the Current Up key or Current Down key to adjust your DCcurrent. The selected output voltage and current values are shown on the digital displays. The LED in keypad Current Up constant current mode. AI A lights up if the unit works in After two seconds without key actuation the actual values are indicated again. 3.2 Constant voltage regulation AI A If a constant voltage is needed, follow these terms: First move the output current to the highest admitted level for your process by using the Current Up or Current Down key. VI A VI A Now use the Voltage Up key or Voltage Down key to adjust your DCvoltage. The selected output voltage and current values are shown on the digital displays. The LED in keypad Voltage Up constant voltage mode. UV V lights up if the unit works in After two seconds without key actuation the actual values are indicated again. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 7/17

4 Using the AH Counter Press the OFF key. Press the A/H RESET key F3 A/H RESET to reset the counter. A short message is displayed: The Ah counter display shows 0.0000 During the process the actual AH count is displayed in the bottom line. To preset the AH counter, press the F4 key F4 SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 8/17

The left decimal is marked: Use the keys point. to set the desired value on the left of the decimal Confirm your setting with ENTER. ENTER The right decimals are marked: Use the keys point. to set the desired value on the right of the decimal Confirm your setting with ENTER ENTER The preset value is stored, and the Ah counter display shows 0.0000 again. The red LED in A/H RESET key is off. If you want to disable the preset counter set the preset value to zero! SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 9/17

5 A/H RESET key functions F3 A/H RESET If the LED in A/H RESET key is off the counter is disabled, that means it is not recording ampere-hours. If the DC power supply is running, you can start the preset counter at any time by pressing the A/H RESET key. The LED in RESET A/H key will light up, and the count starts. Note: You can not stop the preset counter by pressing the A/H RESET key again but you can reset the counter immediately, by pressing the A/H RESET key. The preset counter will automatically stop if the DC power supply is in OFF mode (LED in OFF key lights up continuously). The actual count will be remained. 5.1 Reset If you want to reset the actual count of the preset counter while the process is running, press the A/H RESET key. The preset counter restarts automatically. 5.2 Setting the AH Counter Auto-Start To enable the AH counter to start automatically when the output is switched to the ON position, press the A/H RESET key so that the LED is illuminated before turning on the output to the leads. A/H F3 RESET If the DC power supply is in OFF mode (LED in OFF key lights up continuously) press A/H RESET key to enable auto-start of the preset counter. The LED in A/H RESET key lights up. If the DC power supply is started by pressing the ON key the preset counter will start automatically. Note: In case the preset counter was not reset before turning the main power off the actual count of the preset counter will be stored. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 10/17

6 General description The DC-power supply type SIFCO PROCESS POWER PACK is a sophisticated switch mode type rectifier, designed for the electroplating industry. It is designed as a desk top unit. The control of the output parameters is done by keys in the front panel of the unit. The electronic regulation guarantees correct output parameters during the operation, even with variable loads at the DC output. The pole changer can be programmed individually according to your application. The pole changer can be operated in MANUAL or AUTO mode. The preset counter can be individually configured. The preset counter can be used to switch the DC power supply off after a certain current rate. The A/H RESET key is used to start the preset counter manually (or to enable auto-start) if the plating process is running. Over temperature protection The device is temperature protected. If the interior temperature is exceeding the limit the device decreases the output current automatically and, after a cooling phase, increases it. Do not run the power supply at higher environmental temperatures than 40 C! SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 11/17

7 DC-output connection Connect the plating tank to the DC-output connectors of the power supply by connecting the DC-current output + and - to the tank. Check for right polarity and contact. + The two PLUS terminals have the same potential! 8 Mains supply Supply voltage: 115V AC +/-10% 50-60cps, single phase or Supply voltage: 230V AC +/-10% 50-60cps, single phase Use the connected mains cable to connect the device to the corresponding mains network. Respect the information on the rating plate which is located on the right side panel of the casing. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 12/17

9 Back plane 1 = Power supply cable 2 = X4 terminal 3 = Heat sink 4 = Fuse 5 = Shunt connector: 60mV at I nom. (1 = +Ushunt 2 +3 = Shield 4 = -Ushunt) SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 13/17

10 Key pad functions 10.1 The key pads to the right hand side 10.1.1 Key ON Switch the DC power supply on by using the electronic ON / OFF function. - ON, if LED lights up 10.1.2 Key OFF Switch the DC power supply off - OFF, if LED lights up 10.1.3 Key Enter - Open setup menu - Confirm setting 10.1.4 Key CLR - Cancel procedure, back to operating mode - Receipt error and warning messages, relay reset SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 14/17

10.2 Second key pad row Up Down keys: In standard operating mode the Up Down keys are used to adjust the output voltage and current infinitely. Current and voltage settings: 10.2.1 Key increase voltage Press key to increase the output voltage If LED lights up: constant voltage regulation mode active 10.2.2 Key decrease voltage Press key to decrease the output voltage 10.2.3 Key increase current Press key to increase the output current If LED lights up: constant current regulation active 10.2.4 Key decrease current Press key to decrease the output current As soon as one of the four keys is pressed, the display switches from operating mode to setting mode for current and voltage setting. Short pressing on the key changes the value by one digit. Constant pressing causes continuous change of the value. The changes can also be done if the OFF button (to the right hand side) was pressed (DC power supply switched off electronically). After two seconds without key actuation the actual values are shown again. In setting menu the arrow keys are used to select an item and to adjust the values. SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 15/17

10.3 The key pads to the left hand side 10.3.1 Key +/- Manual pole changing Press key to change polarity, if AUTO mode is not enabled. If AUTO mode is ON and the ON key was pressed you can press +/- key to show the actual position of the pole changer. 10.3.2 Key AUTO, AUTO pole changer mode The pole changing is done by programmed timing for cathodic and anodic position. Press ON key to start the AUTO pole changing *) The LED is used to indicate the AUTO mode. 10.3.3 Key A/H RESET, manual start of preset counter, and reset The A/H RESET key is used to start the preset counter manually (or to enable auto-start) if the plating process is running. If you want to reset the actual count of the preset counter press the A/H RESET key.if the LED lights up the preset counter is enabled (auto start released). 10.3.4 Key F4, direct setting of the preset value *) You can select the start polarity for the automatic pole changing by activating or de-activating the +/- key while AUTO key is on and the LED in Off key lights up (DC output off). Key F4: F4 Attention: The preset counter is not switched ON and OFF by the F4 key. The F4 key is only used for direct setting of the preset value! SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 16/17

10.4 Short circuit detection (overload function) If a direct short between the anode and the part occurs: The display shows: OVERLOAD and a short beep is heard. The DC output is shut off. The LED in OFF key is flashing. The LED in CLR key is flashing. CLR Press CLR key for alarm reset. ON Press the ON key to restart the DC power supply. 11 Warranty and Repair Information This unit has a two year manufacturer s warranty, subject to the terms and conditions of the manufacturer. Warranty/Service Locations: North America, Canada, South America Hendor PE, Inc. 55 Concourse Way Greer, SC 29650 Phone (864) 879-0888 Fax (864)879-4237 Email Werner@hendor-pe.com Europe Plating Electronic GmbH Marie Curie Str. 6 D-79211 Denzlingen, Germany Phone +49 (0) 7666 / 9009-0 Fax +49 (0) 7666 / 9009-44 Email mk@plating.de Asia Solidheat Industries, PTE Ltd. Block 9005, Tampines Street 9 #02-266 Industrial Park A 528839 Singapore Phone 65-6784-7591 Fax 65-6784-7590 Email kelvinsoh@solidheat.com.sg SIFCO-POWER-PACK_1028_Quickstart-Guide_e.doc 17/17