RETANOL XTREME HIGH PERFORMANCE SCREED ADDITIVE WITH FAST DRYING TIMES AND HIGH EARLY STRENGTH.

Similar documents
RETANOL XTREME FOR EXTREMELY HIGH EARLY AND FINAL STRENGTHS. GUARANTEED.

HYDRANOL FOR FLOORCOVERINGS AFTER 28 DAYS.

RETANOL 511/EKA/VIWA FOR PRECISELY ADJUSTABLE DRYING TIMES STARTING WITH 3 DAYS. GUARANTEED.

TECHNICAL INFORMATION CEMSCREED 5

Most products will act differently when installed over an UFH system than when installed on a standard unheated subfloor.

OVS 512 FOR REPAIRING AND REFINING SCREED SURFACES.

Underfloor Heating. BS8425 Code of Practice for Installation of Laminate Floorcoverings and the Code of Practice issued by the

PRODUCT DATA SHEET Sika Level-315 F

TECHNICAL INFORMATION SCREED

INSTALLATION METHOD STATEMENT

TECHNICAL INFORMATION

a new liquid screed solution

Technical data sheet with laying instructions

FLOOR SCREEDS & ADDITIVES SOLUTIONS FOR INDUSTRIAL, RETAIL, RESIDENTIAL & PUBLIC BUILDINGS UZIN. THE FLOOR BELONGS TO YOU.

a new liquid screed solution from

FLOORS AND SCREEDS. ATLAS SAM 55 (1-10 mm) 102 fast setting, self-leveling compound. ATLAS SAM 100 (5-30 mm) 104 fast setting, self-leveling screed

DATA SHEET DEKSTER 131 SELFLEVELLING FLOOR COAT / UNDERLAY

ARDEX A 38TM Rapid Set Screed

FLOORWORX SELF LEVELLING SCREED PRODUCT DATA_

Why screed testing can save your project time and money... Version 01 February 2015

GLUE-DOWN INSTALLATION VIRTUO 30 / 55

Contents. T ec h n i c al data T 01 Why C hange T 0 2 T echnical Data T 0 3 Underfloor Heating T 0 4 Joints

Ultralevel SL Self Levelling Cementitious Underlay

SECTION HYDRAULIC CEMENT UNDERLAYMENT

ARDEX SUBFLOOR RECOMMENDATIONS FOR THE INSTALLATION OF LVT

Multipurpose latex additive for mortar and cementitious adhesive

DURABASE CI 1/5. Underlay mats for decoupling and waterproofing tiled flooring APPLICATIONS AND FUNCTION.

Uniscreed Standard Uniscreed Rapid

Sanitile 945 SL PRODUCT DATA SHEET SELECTION & SPECIFICATION DATA. Generic Type. 100% solids epoxy

Screeds. RonaScreed Underfloor Heating Screed. Rapid drying additive for floating screeds. Description. Drying Time of 50mm screed

cl stuk Technical Sheet Recommended use Materials Substrate

Installation on underfloor heating

a new liquid screed solution from

TECHNICAL DATA SHEET AUS-CRETE PREMIUM INDUSTRIAL

2-part epoxy primer, levelling mortar, intermediate layer and mortar screed

Technical Data Sheet. Ultralevel Bulkout. Self Levelling High Build Cementitious Underlay

CHARACTERISTICS / ADVANTAGES. Yellowish-transparent. PACKAGING 20 kg per pail

ARDEX A 38 MIX Rapid Set, Premixed Screed

APPLICATIONS AND FUNCTION:

15 days 75% Compressive Strength 1 day 23N/mm² 28 days 44N/mm²

DURABASE CI. Underlay mats for decoupling and sealing tiled flooring 1/5 A P P L I C A T I ONS AND FUNCTION.

Fast drying and setting cement for floor screeds (24 hours) hydraulic binder for shrinkage - compensated screeds

The professional s answer to reliable floor preparation.

No reinforcement required 40mm minimum - Commercial applications. 35mm minimum - Domestic applications.

Tips for perfect screed and underfloor heating. Tel: Web: builderscreed.co.uk

Lastogum X. Waterproof, flexible protective coating. Under ceramic coverings in showers and bathrooms

BRANZ Appraisal Certificate # 461 (2010) Internal wet areas.

Subfloor heating and cooling instructions for Hakwood flooring products Duoplank 20mm (¾ ) and Duoplank 15mm (⅝ )

Hanson Multicem is manufactured to comply with the requirements of BS EN CEM II/A-LL (Portlandlimestone cement) strength class 32,5R.

Technical Manual - Section 7 Lytag LWA Roof and Floor Screeds

Data Sheet 3115 Englisch

Sikafloor -161 is an economic, two part, solvent free, low viscosity epoxy resin, suitable for use under hot climate condition.

3-component epoxy self-smoothing screed

AND SUPPORT SMOOTHING & LEVELLING LATEX BASED SPECIFICATION GUIDE // FLOORING RANGE LARTEX FLO LARTEX NA PRODUCT

colorstuk especial n

Cempolatex 1 Pack A CEMENT BASED LATEX SUB-FLOOR SMOOTHING COMPOUND

PRODUCT DATA SHEET Sikadur 31 CF Normal (formerly Sikadur 731)

Mapei systems for radiating floor heating with high thermal efficiency

RonaFloor Repair 1 Hour 2-6mm Repairs to floors Hard standings 2mm to 6mm

MONDO MP 1000 ACRYLIC ADHESIVE DISCLAIMER: Refer to page 5 of this document.

Two-component, highly flexible, cement-based waterproofing slurry

2-part self smoothing epoxy coating, highly chemically and mechanically resistant

No reinforcement required 40mm minimum - Commercial applications. 35mm minimum - Domestic applications.

DEKOGROUT 2/12 Antibacterial, flexible cement-based grout

Polymer bonding aid and mortar additive bonding agent for old and new concrete. Test method Typical result Control. Compressive strength (BS6319,Pt2)

colorstuk 0-4 Technical Sheet Recommended use Materials Substrates Characteristics

ARDEX GUIDE SPECIFICATION ARDEX GS-4 Self-Leveling Repair Underlayment for Distressed Gypsum and Wood Subfloors

Construction. Cementitious self levelling, fast hardening, underlayment for use 2-10mm, and 10-30mm with added aggregate. Product Description

Simalfa 335-Of {Overspray Free}

MASTER FAST C2FT. Improved professional single component cement adhesive with fast setting and reduced slip for tiling.

MorTec DRAIN. MorTec DRAIN Page 1 of 4. Two-part thin-layer epoxy resin drainage mortar DESCRIPTION

Primer and Moisture Control for Wood Floor Bonding with Elastic SikaBond Adhesives on Difficult Substrates

Products for the Tiling Industry

Appearance /Colours Resin - part A: transparent, liquid Hardener - part B: transparent, liquid Packaging. Pre-proportioned 5.

PRODUCT DATA SHEET Sika Levelling Compound

LAYING DIVISION PROFESSIONAL ADHESIVES WITH SAS TECHNOLOGY

FUGABELLA 3-20 LAYING DIVISION

SIMALFA 303. Product Description. Key Properties. Certifications. Physical Properties

Mapecem. Special fast setting and drying (24 hours) hydraulic binder for

TECHNICAL DATA SHEET SIKADUR 31 CF NORMAL 6KG

2-part, electrostatically conductive epoxy coating

POLYMER-MODIFIED TILE ADHESIVES AND GROUTS FOR MODERN CONSTRUCTION. Edition 1.0

GigaCrete Specification PlasterMax. PlasterMax : Fire Rated Plaster for Direct Application over Cement Masonry Units (CMU) Interior Walls

Construction. 3-part cement and epoxy combination micro mortar for surface sealing. Product Description 1 1/5. Tests

TECHNICAL DATA SHEET AUS-BOND INDUSTRIAL LATEX ADMIX

SECTION MORTAR

Part 1 General information. Chapter 1.4. Cold weather working

TECH TALK Sponsored by

colorstuk 2-12 Ceramic tiles with relief to be covered with grouting material.

DUAL EXPANSION. facilitate casting and ensure the total filling of voids even in tight or complex spaces and when working on large surfaces.

PRODUCT DATA SHEET Sikafloor -161

MPA tested! Quality for Professionals. plus Color. Cement Based Jointing Mortar. For light to heavy traffic loads. Cement-based, polymer-modified,

CHAPTER 10: Finishes CONTENTS 10.1 PLASTERWORK 10.2 SECOND AND THIRD FIX FINISHES. Chapter 10

Construction. 2-part High-build Solvent Free Epoxy Coating. Product Description. Product Data. Storage

Refurbishment site guidance for solid-walled houses ground floors

Easy to apply Nonflammable Low odor Castable Make excellent materials of construction

Installation and general maintenance instructions Leoline

Installation and general maintenance instructions Leoline

Preparation Products

Technical Manual Section 8 Rapid Drying Lightweight Screeds

Transcription:

RETANOL XTREME HIGH PERFORMANCE SCREED ADDITIVE WITH FAST DRYING TIMES AND HIGH EARLY STRENGTH. 3

RETANOL XTREME HIGH PERFORMANCE SCREED ADDITIVE WITH FAST DRYING TIMES AND HIGH EARLY STRENGTH. 1. DESCRIPTION Additive for installing fast track low shrinkage and low tension bonded, Un-bonded and floating cement floor screeds. Enhances pumping and workability enormously. 2. PRODUCT BENEFITS Guaranteed drying times: from 48 hrs for tiles and 72 hrs for all other floor coverings. Foot traffic after 24hrs. Approximately 80 90 % of final strength within first 3 4 days. (Obtainable minimum strengths of CT-C40-F6 up to CT-C60-F8 depending on aggregates and amount of cement in accordance with DIN 1045-2). Underfloor heating can be run after 24 hrs (As per PCT Guidelines). Early compressive and flexural strength. Ideal for underfloor heating with improved thermal conductivity. Extended working life with short drying time. Insensitive to moisture, therefore suitable for permanently wet areas. Internal and external. UFH pipes require a minimum of 30 mm coverage over the pipe (As per BS 8204). Bonded screeds from 25 mm, In special cases upon PCT site inspection and assessment, 15 mm depth (with ZE bonding agent) is possible with 0 4 mm Aggregates. Un-bonded and floating screeds from 35 mm. PCT RETANOL XTREME is a TUV certified screed product recognised under EU standards as a construction product with no negative impact on human health when handled or added into a floor screed installation. 3. TUV CERTIFICATION TUV certification involves rigorous testing of the applications for which the component is designed. It includes verification that the product satisfies the strictest European regulations for the industry in which the component was designed for and ensures the component specifications are stated correctly. This is a significant change in the safe use of screed products across the UK construction sector. The full report is available on request. 4. INSTRUCTIONS FOR USE The general guidelines, data sheets and specifications for cement screeds are applicable to the laying and making of PCT RETANOL XTREME screeds. Application temperature: +5 C to max. +28 C (ambient and substrate temperature). A tropical version is available upon request for higher temperature applications. Apply PCT RETANOL XTREME within 90 minutes after mixing. Higher temperatures will reduce and lower temperatures will increase the working life of the screed mix. 5. MIXING INSTRUCTIONS Minimum 62.5 kg of cement, Maximum of 75 kg of cement per 250 litres standard screed pump vessel please refer to the PCT Cement Approval list for suitable types of cement. Dosage: 400 ml of PCT RETANOL XTREME in standard screed pump mixing vessels with 250 litres gross capacity. i.e. 2 litres per M³ (5 pump fillings are assumed at 200 litres each, amounting to 1 m³). Fill the screed pump to about one-half with sand and the entire amount of cement (min 62.5 kg) as usual. Add PCT RETANOL XTREME to the first mixing water (usually 5 10 litres) and then fill the pump completely. Gradually add the required amount of residual water until a pliable consistency is obtained. Tiles can be laid after 48 hrs with 75 kg of cement class 42.5R, all other coverings after 72hrs.

Important Note: cement quantities below 62.5 kg and/or dosages below 400 ml will result in weaker screeds. A simple test for on site moisture checking is the damp earth test. By squeezing a handful of mortar tightly with a gloved hand, when released, the sample should retain its shape and leave the gloved hand slightly moist without running water. Note: A mixing time of 2 minutes ensures proper blending of the products. PCT RETANOL XTREME must never be mixed with other screed or mortar additives. It is important to prepare the screed mixture correctly by ensuring you select the approved cement type, cement quantity and aggregates in accordance with DIN 1045-2, grading curve of Minimum A/B, 0 8 mm, for making floor screed. 0 4 mm aggregates may affect drying time and strength. 6. GENERAL POINTS: Never reactivate screed mortar which is already setting by adding additional water. This also applies to mechanical and manual finishing. Do not apply additional PCT RETANOL XTREME to a screed that is already setting. Always shake PCT RETANOL XTREME well before use. Shake the product at regular intervals (about every 30 minutes) during application. Long standstill periods of the container can cause the ingredients to separate and this may have a negative effect on the performance of the product. Protect the screed from draughts, direct sunlight and excessive heat during the entire application. It may be necessary to darken large window fronts and floor-level glass facade areas to prevent over drying. The correct method to measure moisture content in all PCT RETANOL screeds is by using a CM (carbide method). Electronic measuring devices cannot determine the moisture content in Retanol screeds. WINTER RULES The application of cement screeds in winter at too low temperatures always presents a risk. Not without reason does the cement industry specify a minimum temperature of +5 C for the application of cement. Below this limit, cement reacts very slowly or not at all. The desired strengths and other screed properties might not be obtained. For PCT RETANOL XTREME we have summarized the following 12 Golden PCT Winter Rules for you: 1. Too cold: refuse the application Always follow the BS8204 along with all other relevant guidelines including this Technical Data Sheet 2. Heat the mixing location and building to at least +5 C. Heat the mixing location and building such that the cement and aggregates as well as the applied screed will not freeze and their temperature will not fall below +5. 3. Do not use heating lances. The use of heating lances for heating the screed sand has negive effects on both the sand itself as well as the screed mortar. 4. Room climate: max. +15 C temperature & min. 45 % air humidity. The temperature difference between outside and inside the building must not vary more than +15 C. Further a minimum of 45% rh is recommended inside the building. This prevents thermal shock effects, rapid surface drying and excessive deformation. 5. Do not use floor heating during application. Use other heating methods for frost protection. It is not recommended to use floor heating even at low temperatures. Large deformations frequently occur at joints and edges when using floor heating during application. 6. Avoid warm airflows on and near the screed. Caution regarding heating systems! Forced heating in the building may result in too rapid drying. High temperatures and strong blowers cause detrimental air movement.

7. Heat the building beforehand. Start heating the building at least 5 6 days before screed application. This time is necessary for obtaining the required temperature in cold buildings. 8. Do not use kiln-dried sand 9. Do not use antifreeze agents. 10. Warm water is no help. Example: At 0 C temperature of the base materials cement and sand, the addition of +30 C warm water will only increase the temperature of the screed mixture by +1.6 C. At this temperature neither the cement nor the additives react. Warm water is however suitable for cleaning conveyors and tools. 11. Never leave additives and cement outdoors in vehicles overnight. Additives and cement must never be stored outdoors in vehicles overnight in the winter season. 12. Warm up PCT RETANOL e.g. In warm water, at temperatures of about 15 to 20 C PCT RETANOL has an ideal viscosity and is fully effective. 7. WHEN CAN SCREEDS BE WALKED ON AND SUBJECTED TO LOAD? : PCT RETANOL XTREME screeds can be walked on 24 hours after application. They can be subjected to load if exposed to standard site traffic after 2 days. This means that rolling loads such as wheelbarrows can be used. Note: PCT RETANOL XTREME screeds are floor levelling screeds. Observe British Standards when point-loading. Early subjection to loads may result in damage to the screed surface and/or the screed structure and/or promote crack formation. Screed vibrations must be permanently avoided. The expansion foam strips must not be cut off prior the laying of floor coverings or the grouting process for laying tiles has been completed, and this must be done by the floor layer. 8. DRYING AND VENTILATION OF ROOMS WITH HEATED AND UNHEATED PCT RETANOL XTREME SCREEDS Danger: premature drying and air circulation can cause additional deformation in the screed. Especially in the areas around joints this often results in concave curling or lipping which cannot be rectified, along with a possible height offset between the screed sections. This also increases the risk of crack formation. High indoor air humidity is not conducive to the drying process. This is why regular ventilation is necessary from the second day after completion of the screed installation. All windows and doors must be opened for at least 15 to 20 minutes two or three times a day as a minimum. This enables the necessary air exchange and supports the drying process. In case of insufficient regular ventilation or if rooms are not ventilated, it takes considerably longer to obtain full drying. The heating engineer must prepare a record on the initial heating and the subsequent commissioning. The signed record must be handed over to all relevant parties and contain the following information: All heating data with respective flow temperatures and maximum flow temperature attained. Operating conditions and outdoor temperature upon handover and date of commissioning.

9. UNDERFLOOR HEATING PROTOCOL. WATER TEMPERATURE NOT FLOOR TEMPERATURE All UFH levelling screeds must be able to release the initial tension from the screed which is created upon installation, before the final floor covering is installed. This is not a drying related requirement. Boiler system must be on constant cycle when following the method below. 2/3&7 day dry HEATING PHASES. From the 2nd day after application: water temperature +25 C. From the 3rd day after application: water temperature Max +55 C. From the 4th day after application: water temperature Max +55 C. From the 5th day after application: water temperature +25 C 2nd day means a full 48hrs after completion of the screed installation. The floor temperature must be adjusted to the floor finishing manufacturers requirement. This heating information is only valid when used with this technical data sheet. A CM moisture test must be performed before installing the final floor covering. Shelf life of 9 months stored in ideal conditions. All the information on this product given above is based on extensive practical experience and tests implemented by PCT Performance Chemicals GmbH. However, it is not possible to take all construction site conditions into account and to give suitable instructions for use in each case. It is therefore recommended to verify the applicability, appropriateness and practicability of this information and the intended measures by means of individual tests. PCT assumes warranty for the correctness of this product information and the described properties as well as for the effect of the product. PCT reserves the right to change the product specifications. If the site is or has been supervised by PCT the user is under no obligation to check applicability and appropriateness. Theatre Gütersloh: RETANOL XTREME, CT-C35-F5-S60. Ready for laying: 3 days.

PCT PERFORMANCE CHEMICALS GMBH Patronatstraße 11 13, 71282 Hemmingen Telefon +49 7150 20679-0, Fax +49 7150 20679-200, info@pct-chemie.de, www.pct-chemie.de Stand: Mai 2012. Nur gültig in Verbindung mit weiteren Produktunterlagen der Retanole. 2