Thermal Performance of Nvelope NV1 Clip System

Similar documents
Thermal Performance of Nvelope NV1 Clip System

Thermal Analysis of CL-TALON Cladding Support System

Thermal Performance of Northern Facades ISO Clip System Summary

3-Dimensional Thermal Analysis of Lenmak EnvaTherm and SpandrelTherm Backpan Assemblies

Thermal Bridging and Whole Building Energy Performance

ENCLOSURE SOLUTIONS THERMAL BRIDGING GUIDE FIBERGLAS FOAMULAR THERMAFIBER

Thermal Bridging From Cladding Attachment Strategies Through Exterior Insulation

Is Your Envelope Effective? BCBEC Luncheon January 29, 2009

The Concept of Linear and Point Transmittance and its Value in Dealing with Thermal Bridges in Building Enclosures

Bridging on Building Envelope Performance. A Whole Building Energy Perspective

PART 1 BUILDING ENVELOPE THERMAL ANALYSIS (BETA) GUIDE

ASHRAE Research Project Report RP-1365

Thermal Bridging in Building Thermal Envelope Assemblies: Repetitive Metal Penetrations

FERO RAP TIE AND FAST SYSTEM THERMAL ANALYSIS

Thermal Characteristics of Exterior Building Wall (Above Heritage Building

Break it, or Lose it: Thermal Bridging in Building Envelopes

THERMAL BRIDGING OF MASONRY VENEER CLADDINGS & ENERGY CODE COMPLIANCE

OUTLINE. Building Envelope Thermal Bridging Guide. High Level Overview and Themes. The Code Context. The Energy Context. Where do we go from here?

Accounting for Thermal Bridging at Interface Details. A Methodology for De-Rating Prescriptive Opaque Envelope Requirements in Energy Codes

Armatherm Structural Thermal Bridging Solutions

The Importance of Slab Edge & Balcony Thermal Bridges

Understanding the National Energy Code of Canada for Buildings, 2011

WASHINGTON STATE ENERGY CODE, APPENDIX CHAPTERS

JRS ENGINEERING. Continuous Insulation Overall Effective. Presented by: Marty Deemter, P.Eng. Scott Croasdale, M.Eng, P.Eng, PE

Professional Educational Series BSP716 USGBC # Commercial Building Science Thermal Control in Building Envelopes

Wall Assembly - ACM Metal Panel at Steel Stud Framing SCALE: 3" = 1'-0"

Thermal Bridging in Residential Construction

Cladding Attachment Solutions for Exterior Insulated Commercial Walls

The Effective Thermal Performance of the Building Enclosure: Exterior Walls

Exterior Insulation and the Cascadia Clip Presenter: Maddy Parrott

Residential Energy Code Compliance

Agenda. Scope. Market and code. Impact to Buildings. Design Solution. Future. page 2

Building Envelope

Thermal Bridge Analysis

Meeting & Exceeding Thermal Requirements of the Code

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER-CEMENT SIDING REPORT HOLDER: TAKTL, LLC

Building Envelopes 101

Design No. HI/BP PERIMETER FIRE BARRIER SYSTEM Hilti, Inc. ASTM E 2307 Table 1

Attaching Cladding with Long Screws

Cladding Attachment Through Exterior Insulation Using Long Screws PHIUS 10 TH ANNUAL NAPHC, CHICAGO COLIN SHANE M.ENG, P.ENG 11 SEPTEMBER 2015

Thermal Bridging and Energy Standards 2014 BOABC Education Conference. November 27, 2014

INSULATION VALUES TECHNICAL BULLETIN Vol. 3, No. 1 JANUARY 2017

The Role of Control Layers in Building Enclosure Design

Carter Fabricating Inc. 326 Deerhurst Drive Brampton, Ontario L6T 5H9. Mr. Mike Libreiro

Vanglo House LWPAC. Shannon Estates PERKINS + WILL. Erl Tirol - Festival hall DELUGAN MEISSL. Norma Rose Point Secondary. page 1

ResearcH JournaL 2016 / VOL

Attaching Cladding with Long Screws. Presented by: Michael Aoki-Kramer LEED AP

Johns Manville MinWool Water & Fire Block Mineral Wool Insulation

THE IMPORTANCE OF BALCONY AND SLAB EDGE THERMAL BRIDGES IN CONCRETE CONSTRUCTION

NBC Calculator Tool Manual

Building Enclosure Details and Assemblies for Wood-Frame Buildings

9.36. Energy Efficiency

Building Envelope Thermal Bridging Guide

EVALUATING THE ENERGY SAVINGS OF HIGH PERFORMANCE BUILDING ENCLOSRE RETROFITS Brittany Hanam, MASc, P.Eng. Graham Finch, MASc, P.Eng.

Test Summaries: AWP 1818 & 3030

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

National Institute of Building Sciences

GA GYPSUM BOARD TYPICAL MECHANICAL AND PHYSICAL PROPERTIES

DYNAMIC EFFECT OF THERMAL BRIDGES ON THE ENERGY PERFORMANCE OF RESIDENTIAL BUILDINGS IN BC. Fuad Baba*, Hua Ge

Manitoba Energy Code for Buildings. Part 3 Building Envelope

Steady-State R-Value Calculation. PS-4600 PolySteel Form

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in)

ASTM C 1363 Thermal Performance Test Report

Impact of Insulated Concrete Curb on Concrete Balcony Slab

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

UL Design System HW-D-1012 continued

FIRESTOP JOINT SPRAY CFS-SP WB. 2mm (0.079") WET FILM ± 7.5 ± 5

Building Envelope Thermal Bridging Guide. Insights

Energy equivalent R-value

IMPACT OF CLIMATE CHANGE

Heat & Temperature. Heat Flow. Heat Flow. Overview. Why control heat flow? Dr John Straube Presentation 1. Insulation and Beyond:

Insulation - History. Heat Flow, in 2 and 3 D. Insulation - History. Insulation - History

Deer Ridge Consulting, Inc.

calibrated gas flows from the room burner.

Passive House Solutions Guide

White Paper WP007. Cover 10/13. Energy Codes and Precast Concrete in Colorado. Energy Codes and Precast Concrete in Colorado WP007 WP007

Top plates. Stud. Pre cut stud. 8 ft, 1 1/8 inch. 4 inch brick veneer ½ inch plywood sheathing. Insulation placed between the studs

Carter Architectural Panels Inc. 221 E. Willis Road A Unit 18 Chandler, AZ Mr. Bruce Bourne

INTERNATIONAL CODE COUNCIL 2009/2010 CODE DEVELOPMENT CYCLE

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

Airspace R-Values. Educational Overview. Revised 12/6/2016

Energy Conservation & Building Envelope. Objectives. Introduction. Determine the Building Envelope of a House Calculate Heat Loss of a Building

NATIONAL GYPSUM COMPANY 3-Hour Area Separation Wall System

Wood-Frame wall Assemblies

Thermal Bridging: It Can Be Done Better

Building Envelope Thermal Bridging Guide

BUILDING ENVELOPE By Sabrina D Ambra

Using Thermal Modeling to Evaluate Cladding Support Systems

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: ARCONIC ARCHITECTURAL PRODUCTS, LLC

WALLTITE ECO Air Barrier System. Welcome

When R-Value Doesn t Measure Up

SECTION CLADDING SUPPORT SYSTEMS

Structural and Hygrothermal Field Monitoring of Thick Continuously Insulated Wall Assemblies Utilized in a Multi-Story Residential Building

Managing Condensation and Thermal Performance with Continuous Insulation

Thermal Control Layers: Insulation Materials and Systems

BXUV.V481. Fire Resistance Ratings - ANSI/UL 263. Design/System/Construction/Assembly Usage Disclaimer. Fire Resistance Ratings - ANSI/UL 263

GAF EnergyGuard Polyiso Wall Sheathing

Local Temperature Measurements on Full-Size Systems in the Laboratory: Insight into the Extent of Thermal Bridges in Building Envelope Components

EXTERIOR WALLS. exterior wall systems, cladding w/ masonry. chapters SUBJECT

Transcription:

Report Number: 5140108.00 April 30, 2015 Thermal Performance of Nvelope NV1 Clip System Presented to: Nvelope USA, LLC 16904 164 th Way S.E. Renton, WA 98058 Morrison Hershfield Suite 310, 4321 Still Creek Drive, Burnaby, BC V5C 6S7, Canada Tel 604 454 0402 Fax 604 454 0403 morrisonhershfield.com

TABLE OF CONTENTS Page 1. INTRODUCTION 1 2. MODELING OUTLINE 2 3. THERMAL ANALYSIS 2 3.1 Case 1: Clear Field Thermal Performance of Exterior Insulated Steel Stud Assemblies with NV1 Clip System 5 3.2 Case 2: Clear Field Thermal Performance of Split Insulated Steel Stud Assemblies with NV1 Clip System 6 3.3 Case 3: Clear Field Thermal Performance of Exterior Insulated Castinplace Concrete Wall Assemblies with NV1 Clip System 7 3.4 Case 4: Clear Field Thermal Performance of Exterior Insulated Concrete Block Wall Assemblies with NV1 Clip System 8 4. EXTERIOR INSULATION SENSITIVITY ANALYSIS 9 5. CONCLUSIONS 11 APPENDIX A CLIP SYSTEM DETAILS AND MATERIAL PROPERTIES 12 APPENDIX B ASHRAE 1365RP METHODOLOGY 13 APPENDIX C EFFECTIVE ASSEMBLY RVALUES 14 APPENDIX D SIMULATED TEMPERATURE PROFILES 15

1 1. INTRODUCTION The Nvelope NV1 Thermal Clip System is an aluminum clip system for attaching exterior cladding to various types of exterior insulated wall assemblies. Morrison Hershfield was contracted by Nvelope USA to evaluate the thermal performance of their clip system for several scenarios. The NV1 clip provides an intermittent structural attachment for claddings of exterior insulated wall assemblies. The clip is fabricated from extruded 6005A Aluminum alloy and includes a plastic isolator that reduces thermal bridging between the clip and the backup wall. The vertical flange of the clip has a slot that allows subgirts to be fastened to and adjusted to level the cladding as seen in Figure 1 and 2. For steel stud assemblies, the clips are fastened through the exterior sheathing directly to the steel studs using selfdrilling screws. Several construction scenarios were evaluated for the NV1 Clip System, including varying insulation levels, backup wall assemblies, clip spacing, and types of insulation. Figure 1: NV1 with Girt attachment for 4 insulation and steel stud backup wall Figure 2: NV1 with Girt attachment for 4 insulation and steel stud backup wall (section view)

2 2. MODELING OUTLINE The thermal modeling for this report was performed using the Nx software package from Siemens, which is a general purpose computer aided design (CAD) and finite element analysis (FEA) software suite. The thermal transmittance (UValue) or effective Rvalue was determined using the methodology presented in 1365RP. The methodology, along with modeling assumptions is summarized in Appendix B. The thermal solver and modeling procedures utilized for this study were extensively calibrated and validated for ASHRAE Research Project 1365RP Thermal Performance of Building Envelope Details for Mid and HighRise Construction (1365RP) 1. In addition, an extensive study has been performed for several construction scenarios including various clip attachment methods, with comprehensive results presented in the Building Envelope Thermal Bridging Guide 2. 3. THERMAL ANALYSIS The following section provides the UValue results for several configurations using the NV1 Clip System. The base case scenario, Case 1, is an exterior insulated steel stud wall assembly with mineral wool insulation ranging from 3 to 6 inches, and vertical subgirts (See Figure 3). Clips are spaced 16 o.c. horizontally and vertical spacing varies. Figure 3: Case 1: Exterior Insulated Steel Stud Wall Assembly with Vertical Girts 1 http://www.morrisonhershfield.com/ashrae1365research/pages/insightspublications.aspx 2 http://www.bchydro.com/powersmart/business/programs/newconstruction.html?wt.mc_id=rd_construction

3 Case 2 is a split insulated steel stud assembly with R12 fiberglass batt insulation in the stud cavity (See Figure 4). Clips are spaced 16 o.c. horizontally and vertical spacing varies. Figure 4: Case 2: Split Insulated Steel Stud Wall Assembly with Vertical Girts and R12 batt insulation Case 3 is an exterior insulated pouredinplace concrete wall assembly (See Figure 5). Clips are spaced 24 o.c. horizontally and vertical spacing varies. Figure 5: Case 3: Exterior Insulated Pouredinplace Concrete Wall Assembly

4 Case 4 is an exterior insulated concrete block wall assembly (See Figure 6). Clips are spaced 24 o.c. horizontally and vertical spacing varies. Figure 6: Case 4: Exterior Insulated Concrete Block Wall Assembly Assembly images for these systems, outlining the components and material properties are found in Appendix A. Temperature profiles for the evaluated scenarios are given in Appendix D. Effective Rvalues are presented in Appendix C. Cases one through four are discussed further in the following sections. A sensitivity analysis was performed to demonstrate that the conductivity of exterior insulation, and thickness, does not have a significant impact on the results and generic insulation levels can be used for any type of exterior insulation.

5 3.1 Case 1: Clear Field Thermal Performance of Exterior Insulated Steel Stud Assemblies with NV1 Clip System Thermal performance results of the NV1 Clip System with vertical subgirts are presented in Table 1. The results include spacing of the clips ranging from 24 to 48 vertically and 16 o.c. horizontally to line up with the steel studs. Varying levels of exterior mineral wool insulation (R 4.2 per inch) are presented. The results include all the components of the steel stud assembly, including 3 5/8 (90 mm) steel studs spaced at 16 o.c. and exterior sheathing and interior drywall. The exterior cladding and cavity was not explicitly modelled, but the effects of the cladding and air space were simulated by adjusting the exterior air film coefficient accordingly. Effective Rvalues are given in Table C.1 in Appendix C. Temperature profiles are presented in Appendix D. The overall effectiveness of the thermal insulation for the vertical subgirt system ranges from 65% to 84% depending on the vertical clip spacing and insulation level. In comparison, the effectiveness of insulation in typical continuous vertical girt systems ranges from 43% to 58% over the same range of insulation levels 3. Table 1: Thermal Transmittance Uvalues for Exterior Insulated Steel Stud Wall Assemblies with NV1 Clip System (Case 1) Effective Assembly UValue BTU/hr ft 2 of (W/m 2 K) Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 4 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip Spacing 36 Vertical Clip Spacing 48 Vertical Clip Spacing 3 12.6 (2.22) 0.082 (0.463) 0.077 (0.440) 0.075 (0.429) 4 16.8 (2.96) 0.068 (0.386) 0.063 (0.359) 0.061 (0.346) 5 21.0 (3.70) 0.060 (0.340) 0.055 (0.310) 0.052 (0.295) 6 25.2 (4.44) 0.050 (0.308) 0.049 (0.276) 0.046 (0.260) 3 Results in ASHRAE 1365RP Final Report and Building Envelope Thermal Bridging Guide 4 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the steel stud wall, cladding cavity and interior air films add an approximate nominal R3.2 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

6 3.2 Case 2: Clear Field Thermal Performance of Split Insulated Steel Stud Assemblies with NV1 Clip System For Case 2, the wall assemblies were simulated with R12 fiberglass batt insulation in the steel stud cavity. The thermal transmittance Uvalues for these split insulated assemblies are summarized in Table 2 ( effective Rvalues are given in Table C.2). Temperature profiles are given in Appendix D. Table 2: Thermal Transmittance Uvalues for Split Insulated Steel Stud Wall with NV1 Clip System and R12 Batt Insulation in Stud Cavity (Case 2) Effective Assembly UValue BTU/hr ft 2 of (W/m 2 K) Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 5 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip Spacing 36 Vertical Clip Spacing 48 Vertical Clip Spacing 2 8.4 (1.48) 0.063 (0.360) 0.062 (0.350) 0.061 (0.345) 3 12.6 (2.22) 0.055 (0.314) 0.053 (0.300) 0.052 (0.293) 4 16.8 (2.96) 0.049 (0.277) 0.046 (0.260) 0.044 (0.252) 5 21.0 (3.70) 0.044 (0.252) 0.041 (0.233) 0.039 (0.223) 6 25.2 (4.44) 0.041 (0.234) 0.037 (0.213) 0.036 (0.202) Adding batt insulation to the steel stud cavity is often considered during design to meet specific building envelope thermal transmittance targets and to minimize the thickness of the exterior wall depth. With batt insulation, the Uvalue of the assembly is improved but the effectiveness of the insulation is reduced. This is due to the thermal bridging of the steel studs. For the NV1 Clip System, adding R12 batt reduces the overall effectiveness of the insulation to a range of 61% to 73% depending on the spacing and amount of insulation. The addition of R12 batt insulation results, on average, in an R6 increase in the effective insulation value of the wall. 5 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the steel stud wall with batt insulation, cladding cavity and interior air films add an approximate nominal R14.3 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

7 3.3 Case 3: Clear Field Thermal Performance of Exterior Insulated Castinplace Concrete Wall Assemblies with NV1 Clip System For Case 3, the wall assemblies were simulated with an 8 castinplace concrete wall that includes an interior 15/8 steel stud wall. The thermal transmittance Uvalues for this assembly is summarized in Table 4 ( effective Rvalues are given in Table C.3). Temperature profiles are given in Appendix D. The results incorporate all the components of the castinplace concrete wall assembly, including 1 5/8 (90 mm) steel studs and interior drywall. Results also include spacing of the clips ranging from 24 to 48 vertically and 24 o.c. horizontally. The overall effectiveness of the thermal insulation for the vertical subgirt system ranges from 68% to 91% depending on the vertical clip spacing and insulation level. Table 3: Thermal Transmittance Uvalues for Exterior Insulated Castinplace Concrete Wall Assemblies with NV1 Clip System (Case 3) Effective Assembly UValue BTU/hr ft 2 of (W/m 2 K) Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 6 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip Spacing 36 Vertical Clip Spacing 48 Vertical Clip Spacing 2 8.4 (1.48) 0.098 (0.557) 0.095 (0.540) 0.094 (0.532) 3 12.6 (2.22) 0.078 (0.443) 0.075 (0.423) 0.073 (0.412) 4 16.8 (2.96) 0.065 (0.371) 0.061 (0.347) 0.059 (0.335) 5 21.0 (3.70) 0.057 (0.326) 0.053 (0.300) 0.050 (0.286) 6 25.2 (4.44) 0.052 (0.294) 0.047 (0.267) 0.044 (0.252) 6 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the concrete wall, cladding cavity and interior air films add an approximate nominal R3.3 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

8 3.4 Case 4: Clear Field Thermal Performance of Exterior Insulated Concrete Block Wall Assemblies with NV1 Clip System For Case 4, the wall assemblies were simulated with a standard concrete block wall that includes an interior 15/8 stud wall. The thermal transmittance Uvalues for this assembly is summarized in Table 4 ( effective Rvalues are given in Table C.4). Temperature profiles are given in Appendix D. The results incorporate all the components of the concrete block wall assembly, including 1 5/8 (90 mm) steel studs and interior drywall. The results also include spacing of the clips ranging from 24 to 48 vertically and 24 o.c. horizontally. The overall effectiveness of the thermal insulation for the vertical subgirt system ranges from 69% to 92% depending on the vertical clip spacing and insulation level. Table 4: Thermal Transmittance Uvalues for Exterior Insulated Concrete Block Wall Assemblies with NV1 Clip System (Case 4) Effective Assembly UValue BTU/hr ft 2 of (W/m 2 K) Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 7 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip Spacing 36 Vertical Clip Spacing 48 Vertical Clip Spacing 2 8.4 (1.48) 0.092 (0.523) 0.090 (0.509) 0.088 (0.502) 3 12.6 (2.22) 0.074 (0.420) 0.071 (0.402) 0.069 (0.393) 4 16.8 (2.96) 0.062 (0.353) 0.058 (0.332) 0.057 (0.321) 5 21.0 (3.70) 0.055 (0.311) 0.051 (0.288) 0.048 (0.275) 6 25.2 (4.44) 0.049 (0.281) 0.045 (0.256) 0.043 (0.243) 7 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the concrete block wall, cladding cavity and interior air films add an approximate nominal R3.9 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

9 4. EXTERIOR INSULATION SENSITIVITY ANALYSIS A sensitivity analysis was performed for the thermal performance of the system to different assumptions for insulation conductivity: R3.5/in exterior insulation R6.5/in exterior insulation The previous analysis assumed semirigid (R 4.2/inch) for the exterior insulation. Other conductivities were evaluated to allow the thermal transmittance values for the thermal clip system to be utilized for other types of insulation (see Table 5). In order to characterize the range of exterior insulation values, the modeled assemblies in section 3.1 were recalculated using a low end of R3.5 per inch (RSI 0.62 per inch) to a high end of R6.5 per inch (RSI 1.14 per inch). Table 5: Sensitivity Analysis for Exterior Insulated Steel Stud Wall with Vertical Girts, Clips 24 o.c. vertically, and Studs Spaced 16" o.c. with alternate insulation types Effective Assembly UValue BTU/hr ft 2 of (W/m 2 K) Insulation Conductivity Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 4 hr ft 2 of/btu (m 2 K/W) 24 Vertical Clip Spacing 3 10.5 (1.85) 0.091 (0.516) R3.5/inch 4 14.0 (2.47) 0.076 (0.431) 5 17.5 (3.08) 0.067 (0.379) 6 21.0 (3.70) 0.060 (0.342) 3 19.5 (3.43) 0.063 (0.357) R6.5/inch 4 26.0 (4.58) 0.053 (0.300) 5 32.5 (5.72) 0.047 (0.266) 6 39.0 (6.87) 0.043 (0.243) Figure 7 shows the graphical results for effective assembly Rvalues with a clip spacing of 24 vertically and 16 horizontally with no batt insulation when varying the exterior insulation materials. The results show that the thickness of the insulation (and the length of the clip) for a given nominal thermal resistance is largely independent of the effective Rvalue. Therefore, the results can be characterized by the Rvalue of the exterior insulation and can be applied to any material.

10 The results from Table 5 can be rearranged and additional Rvalues can be interpolated with results from the sensitivity analysis. The Uvalue results are presented in Table 3 and Rvalue results are found in Appendix C. As an example, 3 inches of R5 exterior (R15) insulation will yield an effective Rvalue of approximately R13.5 as shown with the red arrows in Figure 7. 25.0 20.0 Effective Assembly Rvalue 15.0 10.0 R 3.5/in R 6.5/in R 4.2/in 5.0 0.0 0 5 10 15 20 25 30 35 40 45 Insulation 1D Rvalue Figure 7: Case 1: Exterior Insulated Steel Stud Wall Assembly with Alternate Insulation

11 5. CONCLUSIONS Overall, the NV1 System provides an effective means of reducing thermal bridging in wall assemblies compared to traditional continuous girt systems. The Uvalues provided by this report can be used for compliance calculations through any of the compliance paths set forth in relevant energy codes and standards such as ASHRAE 90.1, IECC, an/or NECB. Morrison Hershfield Radu Postole, BASc. Building Science Consultant Patrick Roppel, P.Eng. Building Science Specialist

A1 APPENDIX A CLIP SYSTEM DETAILS AND MATERIAL PROPERTIES

A2 NV1 Clip System Exterior Insulated Steel Stud Assembly with Vertical Subgirts Clip Detail ID Component Thickness Inches (mm) Conductivity Btu in / ft 2 hr F (W/m K) Nominal Resistance hr ft 2 F/Btu (m 2 K/W) Density lb/ft 3 (kg/m 3 ) Specific Heat Btu/lb F (J/kg K) 1 Interior Film R0.7 (0.12 RSI) 2 Gypsum Board 1/2" (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 3 Air in Stud Cavity 3 5/8 (92) R0.9 (0.16 RSI) 0.075 (1.2) 0.24 (1000) 4 3 5/8 x 1 5/8 Steel Studs 18 Gauge 430 (62) 489 (7830) 0.12 (500) 5 Exterior Sheathing 1/2 (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 6 Exterior Insulation (Mineral Wool) 3 to 6 (76 to 152) 0.24 (0.034) R12.6 to R25.2 (2.22 RSI to 4.44 RSI) 4 (64) 0.20 (850) 7 NV1 Clip Isolator 0.2" (5) 0.82 (0.117) 8 NV1 Clip Extrusion Aluminum 6005A alloy varies 1340 (193) 9 Bolts Stainless Steel 1/4" D (6D) 118 (17) 10 Vertical Subgirt 0.09 (2.2) 1340 (193) 11 Generic Cladding with 1/2 (13mm) vented air space is incorporated into exterior heat transfer coefficient 12 Exterior Film R0.7 (0.12 RSI) * NV1 clip @ 24 spacing vertically and 16 horizontally, with 4 exterior insulation and no batt insulation as shown in images

A3 NV1 Clip System Split Insulated Steel Stud Assembly with Vertical Subgirts Clip Detail ID Component Thickness Inches (mm) Conductivity Btu in / ft 2 hr F (W/m K) Nominal Resistance hr ft 2 F/Btu (m 2 K/W) Density lb/ft 3 (kg/m 3 ) Specific Heat Btu/lb F (J/kg K) 1 Interior Film R0.7 (0.12 RSI) 2 Gypsum Board 1/2" (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 3 4 Fiberglass Batt Insulation 3 5/8 x 1 5/8 Steel Studs 3 5/8 (92) 0.29 (0.042) R12 (2.2 RSI) 0.9 (14) 0.17 (710) 18 Gauge 430 (62) 489 (7830) 0.12 (500) 5 Exterior Sheathing 1/2 (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 6 Exterior Insulation (Mineral Wool) 2 to 6 (50 to 152) 0.24 (0.034) R8.4 to R25.2 (1.48 RSI to 4.44 RSI) 4 (64) 0.20 (850) 7 NV1 Clip Isolator 0.2" (5) 0.82 (0.117) 8 NV1 Clip Extrusion Aluminum 6005A alloy varies 1340 (193) 9 Bolts Stainless Steel 1/4" D (6D) 118 (17) 10 Vertical Subgirt 0.09 (2.2) 1340 (193) 11 Generic Cladding with 1/2 (13mm) vented air space is incorporated into exterior heat transfer coefficient 12 Exterior Film R0.7 (0.12 RSI) * NV1 clip @ 24 spacing vertically and 16 horizontally, with 4 exterior insulation and batt insulation as shown in images

A4 NV1 Clip System Exterior Insulated Castinplace Concrete Wall Assembly with Vertical Subgirts Clip Detail ID Component Thickness Inches (mm) Conductivity Btu in / ft 2 hr F (W/m K) Nominal Resistance hr ft 2 F/Btu (m 2 K/W) Density lb/ft 3 (kg/m 3 ) Specific Heat Btu/lb F (J/kg K) 1 Interior Film R0.7 (0.12 RSI) 2 Gypsum Board 1/2" (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 3 Air in Stud Cavity 1 5/8 (41) R0.9 (0.16 RSI) 0.075 (1.2) 0.24 (1000) 4 1 5/8 x 1 5/8 Steel Studs 18 Gauge 430 (62) 489 (7830) 0.12 (500) 5 Concrete Wall 8 (203) 12.5 (1.8) 140 (2250) 0.20 (850) 6 Exterior Insulation (Mineral Wool) 2 to 6 (50 to 152) 0.24 (0.034) R8.4 to R25.2 (1.48 RSI to 4.44 RSI) 4 (64) 0.20 (850) 7 NV1 Clip Isolator 0.2" (5) 0.82 (0.117) 8 NV1 Clip Extrusion Aluminum 6005A alloy varies 1340 (193) 9 Bolts Stainless Steel 1/4" D (6D) 118 (17) 10 Vertical Subgirt 0.09 (2.2) 1340 (193) 11 Generic Cladding with 1/2 (13mm) vented air space is incorporated into exterior heat transfer coefficient 12 Exterior Film R0.7 (0.12 RSI) * NV1 clip @ 24 spacing vertically and 24 horizontally, with 4 exterior insulation is shown in images

A5 NV1 Clip System Exterior nsulated Concrete Block Wall Assembly with Vertical Subgirts Clip Detail ID Component Thickness Inches (mm) Conductivity Btu in / ft2 hr F (W/m K) Nominal Resistance hr ft2 F/Btu (m2k/w) Density lb/ft3 (kg/m3) Specific Heat Btu/lb F (J/kg K) R0.7 (0.12 RSI) 1/2" (13) 1.1 (0.16) R0.5 (0.08 RSI) 50 (800) 0.26 (1090) 1 Interior Film 2 Gypsum Board 3 Air in Stud Cavity 1 5/8 (41) R0.9 (0.16 RSI) 0.075 (1.2) 0.24 (1000) 4 1 5/8 x 1 5/8 Steel Studs 18 Gauge 430 (62) 489 (7830) 0.12 (500) 5 Standard Concrete Block 75/8 (190) R1.2 (0.22 RSI) 119 (1900) 0.19 (800) 6 Exterior Insulation (Mineral Wool) 2 to 6 (50 to 152) 0.24 (0.034) R8.4 to R25.2 (1.48 RSI to 4.44 RSI) 4 (64) 0.20 (850) 7 NV1 Clip Isolator 0.2" (5) 0.82 (0.117) 8 NV1 Clip Extrusion Aluminum 6005A alloy varies 1340 (193) 9 Bolts Stainless Steel 1/4" D (6D) 118 (17) 10 Vertical Subgirt 0.09 (2.2) 1340 (193) 11 12 Generic Cladding with 1/2 (13mm) vented air space is incorporated into exterior heat transfer coefficient Exterior Film R0.7 (0.12 RSI) * NV1 clip @ 24 spacing vertically and 24 horizontally, with 4 exterior insulation is shown in images

B1 APPENDIX B ASHRAE 1365RP METHODOLOGY

B2 B.1 General Modeling Approach For this report, a steadystate conduction model was used. The following parameters were also assumed: Air cavities were assumed to have an effective thermal conductivity which includes the effects of cavity convection. Interior/exterior air films were taken from Table 1, p. 26.1 of 2009 ASHRAE Handbook Fundaments depending on surface orientation. Cladding and vented rainscreen cavity airspaces were not explicitly modelled and their thermal resistance was added to the exterior air film From the calibration in 1365RP, contact resistances between materials were modeled. The temperature difference between interior and exterior was modeled as a dimensionless temperature index between 0 and 1 (see Appendix B.3). These values, along with other modeling parameters, are given in ASHRAE 1365RP, Chapter 5. B.2 Thermal Transmittance The methodology presented in ASHRAE 1365RP separates the thermal performance of assemblies and details in order to simplify heat loss calculations. For the assemblies, a characteristic area is modeled and the heat flow through that area is found. To find the effects of thermal bridges in details (such as slab edges), the assembly is modeled with and without the detail. The difference in heat loss between the two models is then prescribed to that detail. This allows the thermal transmittances to be divided into three categories: clear field, linear and point transmittances. The clear field transmittance is the heat flow from the wall or roof assembly, including uniformly distributed thermal bridges that are not practical to account for on an individual basis, such as structural framing, brick ties and cladding supports. This is treated the same as in standard practice, defined as a Uvalue, Uo (heat flow per area). For a specific area of opaque wall, this can be converted into an overall heat flow per temperature difference, Qo. The linear transmittance is the additional heat flow caused by details that can be defined by a characteristic length, L. This includes slab edges, corners, parapets, and transitions between assemblies. The linear transmittance is a heat flow per length, and is represented by psi (Ψ). The point transmittance is the heat flow caused by thermal bridges that occur only at single, infrequent locations. This includes building components such as pipe penetrations and intersections between linear details. The point transmittance is a single additive amount of heat, represented by chi (χ). With these thermal quantities the overall heat flow can be found simple by adding all the components together, as given in equation 1. thermalbridge o ( Ψ L) + Σ ( ) Qo Q = ΣQ + Q = Σ χ + EQ 1

B3 Equation 1 gives the overall heat flow for a given building size. For energy modeling, or comparisons to standards and codes, often it is more useful to present equation 1 as a heat flow per area. Knowing that the opaque wall area is A total, and U=Q/At otal, equation 2 can be derived. ( Ψ L) + Σ ( χ) Σ U = + U A Total o EQ 2 Since the linear and point transmittances are simply added amounts of heat flow, they can be individually included or excluded depending on design requirements. For this report, no point transmittance details were analyzed. B.2 Temperature Index For condensation concerns, the thermal model can also provide surface temperatures of assembly components to help locate potential areas of risk. In order to be applicable for any climate (varying indoor and outdoor temperatures), the temperatures can been nondimensionalized into a temperature index, T i, as shown below in Equation 3. = EQ 3 The index is the ratio of the surface temperature relative to the interior and exterior temperatures. The temperature index has a value between 0 and 1, where 0 is the exterior temperature and 1 is the interior temperature. If T i is known, Equation 3 can be rearranged for T surface. Example temperature profiles for the assemblies and details modeled in this report are shown in Appendix C.

C1 APPENDIX C EFFECTIVE ASSEMBLY RVALUES

C2 C.1 Case 1: Thermal Performance of Exterior Insulated Steel Stud Assemblies with NV1 Clip System Table C.1: Thermal Resistance for Exterior Insulated Steel Stud Wall Assemblies with NV1 Clip System (Case 1). Clips spaced 16 horizontally Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 1 hr ft 2 of/btu (m 2 K/W) 24 Vertical Spacing Assembly Effective RValue hr ft 2 of/btu (m 2 K/W) 36 Vertical Spacing 48 Vertical Spacing 3 12.6 (2.22) R12.3 (2.16) R12.9 (2.28) R13.3 (2.33) 4 16.8 (2.96) R14.7 (2.59) R15.8 (2.78) R16.4 (2.89) 5 21.0 (3.70) R16.7 (2.94) R18.3 (3.23) R19.2 (3.39) 6 25.2 (4.44) R18.4 (3.25) R20.6 (3.63) R21.9 (3.85) Figure C.1: Case 1: Exterior Insulated Steel Stud Wall Assembly with Vertical Girts 1 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the steel stud wall, cladding cavity and interior air films add an approximate nominal R3.2 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

C3 C.2 Case 2: Thermal Performance of Split Insulated Steel Stud Assemblies with NV1 Clip System Table C.2: Thermal Resistance for Split Insulated Steel Stud Wall with NV1 Clip System and R12 Batt Insulation in Stud Cavity (Case 2). Clips spaced 16 horizontally Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 2 hr ft 2 of/btu (m 2 K/W) 24 Vertical Spacing Assembly Effective RValue hr ft 2 of/btu (m 2 K/W) 36 Vertical Spacing 48 Vertical Spacing 2 8.4 (1.48) R15.8 (2.78) R16.2 (2.86) R16.5 (2.90) 3 12.6 (2.22) R18.1 (3.19) R18.9 (3.33) R19.3 (3.41) 4 16.8 (2.96) R20.5 (3.61) R21.9 (3.85) R22.6 (3.97) 5 21.0 (3.70) R22.5 (3.96) R24.4 (4.30) R25.4 (4.48) 6 25.2 (4.44) R24.2 (4.27) R26.7 (4.70) R28.1 (4.95) Figure C.2: Case 2: Split Insulated Steel Stud Wall Assembly with Vertical Girts and R12 batt insulation 2 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the steel stud wall with batt insulation, cladding cavity and interior air films add an approximate nominal R14.3 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

C4 C.3 Case 3: Thermal Performance of Exterior Insulated Castinplace Concrete Wall Assemblies with NV1 Clip System Table C.3: Thermal Resistance for Exterior Insulated Castinplace Concrete Wall with NV1 Clip System (Case 3). Clips spaced 24 horizontally Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 3 hr ft 2 of/btu (m 2 K/W) 24 Vertical Spacing Assembly Effective RValue hr ft 2 of/btu (m 2 K/W) 36 Vertical Spacing 48 Vertical Spacing 2 8.4 (1.48) R10.2 (1.79) R10.5 (1.85) R10.7 (1.88) 3 12.6 (2.22) R12.8 (2.26) R13.4 (2.36) R13.8 (2.43) 4 16.8 (2.96) R15.3 (2.7) R16.4 (2.88) R17 (2.99) 5 21.0 (3.70) R17.4 (3.07) R18.9 (3.33) R19.9 (3.5) 6 25.2 (4.44) R19.3 (3.4) R21.3 (3.75) R22.5 (3.97) Figure C.3: Case 3: Exterior Insulated Pouredinplace Concrete Wall Assembly 3 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the concrete wall, cladding cavity and interior air films add an approximate nominal R3.3 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

C5 C.4 Case 4: Thermal Performance of Exterior Insulated Concrete Block Assemblies with NV1 Clip System Table C.4: Thermal Resistance for Exterior Insulated Concrete Block Wall with NV1 Clip System (Case 4). Clips spaced 24 horizontally Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 4 hr ft 2 of/btu (m 2 K/W) 24 Vertical Spacing Assembly Effective RValue hr ft 2 of/btu (m 2 K/W) 36 Vertical Spacing 48 Vertical Spacing 2 8.4 (1.48) R10.8 (1.91) R11.2 (1.96) R11.3 (1.99) 3 12.6 (2.22) R13.5 (2.38) R14.1 (2.49) R14.4 (2.54) 4 16.8 (2.96) R16.1 (2.83) R17.1 (3.01) R17.7 (3.12) 5 21.0 (3.70) R18.3 (3.22) R19.7 (3.48) R20.6 (3.63) 6 25.2 (4.44) R20.2 (3.56) R22.2 (3.91) R23.4 (4.12) Figure C.4: Case 4: Exterior Insulated Concrete Block Wall Assembly 4 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the concrete block wall, cladding cavity and interior air films add an approximate nominal R3.9 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

C6 C.5 Case 5: Thermal Performance of Exterior Insulated Steel Stud Assemblies with NV1 Clip System and Alternate Insulation Table C.5: Sensitivity Analysis for Exterior Insulated Steel Stud Wall with Vertical Girts and Studs Spaced 16" o.c. with alternate insulation types Insulation Conductivity Exterior Insulation Thickness (in) Exterior Insulation Nominal RValue 5 hr ft 2 of/btu (m 2 K/W) Assembly Effective RValue hr ft 2 of/btu (m 2 K/W) 24 Vertical Spacing 3 10.5 (1.85) R11.0 (1.94) R3.5/inch 4 14.0 (2.47) R13.2 (2.32) 5 17.5 (3.08) R15.0 (2.64) 6 21.0 (3.70) R16.6 (2.92) 3 19.5 (3.43) R15.9 (2.80) R6.5/inch 4 26.0 (4.58) R18.9 (3.34) 5 32.5 (5.72) R21.3 (3.75) 6 39.0 (6.87) R23.3 (4.11) Figure C.5: Exterior Insulated Steel Stud Wall Assembly with Vertical Girts and Alternate Insulation (Mineral Wool shown) 5 This is only the exterior insulation nominal Rvalue. Without taking into account thermal bridging, the steel stud wall, cladding cavity and interior air films add an approximate nominal R3.2 to the assembly. This additional thermal resistance is included when assessing the effectiveness of the system.

D1 APPENDIX D SIMULATED TEMPERATURE DISTRIBUTIONS

D2 Figure D.1: Temperature profile for Case 1 with 4 exterior insulation and clips spaced 24 o.c. vertically and 16 o.c. horizontally. Steel stud wall with no interior insulation. Figure D.2: Temperature profile for Case 2 with 4 exterior insulation and clips spaced 24 o.c. vertically and 16 o.c. horizontally. Steel stud wall with interior insulation.

D3 Figure D.3: Temperature profile for Case 3 with 4 exterior insulation and clips spaced 24 o.c. vertically and 24 o.c. horizontally. Figure D.4: Temperature profile for Case 4 with 4 exterior insulation and clips spaced 24 o.c. vertically and 24 o.c. horizontally.