Coupled windows in the current guise

Similar documents
Folly or innovation suggestions for a sensible approach to the U-value Olympics

Justifiability Installation of New Types of Window

GLASS SELECTION GUIDE

CEN/TC 89 - Thermal performance of buildings and building components

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

A well-planned building envelope is a requirement for achieving high user comfort and low energy costs.

Repairing Windows and Doors. Mon

Lecture 3: Utilization of Passive Solar Technology

Observation of Liquid-filled Window without Presence of Liquid in Test Chamber

Facade system Thermo 50 with superior insulation (RMG 1) SFB 4150


*) This is a translation of Test Report dated 07 August Window system M 9400 SOFTLINE PLUS Frame material: Aluminium

Funding. Funding for this class was provided by the Alaska Housing Finance Corporation (AHFC).

OKAWOOD - Insulating Glass with Wooden Grid

PVC-U: Innovations and product ranges

inter.noise 2000 The 29th International Congress and Exhibition on Noise Control Engineering August 2000, Nice, FRANCE

OKAWOOD - Insulating Glass with Wooden Grid

BUILDING SYSTEMS FOR BUILDING PROFESSIONALS WHO WANT TO GET MORE DONE IN LESS TIME

Product information Vertical window element VFE

Moisture problems of functional joints of wooden windows causes analysis

European Timber Windows & Doors

Window Labelling Program for India

OKAWOOD - Insulating Glass with Wooden Grid

The Double Glass Skin Façade: a sustainable option for the Curtain Wall in Mediterranean Climate Countries?

INCREASE THE VALUE AND COMFORT OF YOUR HOME. Saving Energy, Saves Money. and lower monthly costs with energy efficiency features.

Constructions Database User Guide IES Virtual Environment 6.3

SMART SOLUTIONS DOUBLE GLAZING SOLAR COMFORT TINTING GLASS ASK OUR SALES REPRESENTATIVES ABOUT. Reduce your 23% energy costs * by as much as

INSTALLATION MANUAL FOR WOOD ALUMINIUM GLAZED STRUCTURES. AILE COto

ENERGY EFFICIENT RETROFIT MEASURES GUIDE

WEEDOO - SA CONSTRUCTION TECHNOLOGY

Energy Gaining Windows for Residential Buildings

Q-Air unique selling propositions in detail

Application technology, 5th edition. Volume III: Fonterra radiant heating and cooling

Senior Design Project for UNO. Design of the International Studies Building: An Environmental Analysis

Evidence of Performance Calculation of thermal transmittance

Glazing with Integral Sun Control Louvres

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

Consumer Guide to Window and Door Replacement

Experience. top performance. U w up to. W/(m 2 K) KBE 76 Centre seal system

GLASOASE MORE TIME OUTSIDE: EXTEND YOUR PATIO SEASON WITH GLASOASE

Sustainable Building Façade and Advanced Fenestration Systems

SUNCE Marinkovic d.o.o. Lepenicki bulevar br Kragujevac Serbia. Hollow chamber profile - plastic Profile combination: Casement-frame

4. Insulation of external walls

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

INFOTEXT. OKALUX Light Diffusing Insulating Glass. Physical properties

CENTRA WINDOWS. Manufacturer for Centra Construction Group of Companies

ECOTOP VF-HF. high efficiency glazed flat-plate solar collectors > MAXIMUM MODULARITY > SIMPLIFIED INSTALLATION

Code of practice for the use of triple thermal insulating glass units

OKALUX GmbH Marktheidenfeld Germany Tel.: +49 (0) Fax: +49 (0)

Comparison of the Effects of Various Countermeasures on Energy Consumption in a Residential Building

SECTION SPECIALTY FILMS FOR GLASS ENHANCEMENT (DECORATIVE) RED SR HPR

A Product of Sudhakar Pipes & Fittings. upvc FRAMES

Selecting Energy Efficient New Windows in Tennessee

Refurbishment site guidance for solid-walled houses windows and doors

Glazing with Integral Sun Control Louvres

Assessing the energy performance of modern glass facade systems

Product information Top-operated centre-pivot polyurethane roof window GGU

The insulating glass for more light and heat

Selecting Energy Efficient New Windows in Nevada

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Product information Vertical window element VIU

Product information Roof balcony CABRIO GDL

Catalogue of Learning Targets

TREES Training for Renovated Energy Efficient Social housing. Section 1 Techniques 1.2 Replacement of glazing

Double layer glass façade in the refurbishment and architectural renewal of existing buildings in Italy

Selecting Energy Efficient New Windows in Illinois

Presentation to Irish Building Control Institute

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

WINDOWS & DOORS SYSTEMS

WINDOWS & DOORS SYSTEMS

Product information Roof balcony CABRIO GDL

Martin Ratcliffe Visiting Research Fellow, Centre for Energy Studies at LSBU Head of Roger Preston Environmental

Selecting Energy Efficient Replacement Windows in Arizona

FEDERATION TOWER MOSCOW DIFFERENT ROOM CLIMATES UNDER ONE ROOF

Secondary. Double Glazing. The alternative to upvc & aluminium double glazing. Glass & Windows

The reasons for this approach are different. So

Energy Efficient Building Envelope Kiev,

Narrow Cavity Insulating Glass Units (IGU s) with Reduced Spacer-bar Sightlines

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

SLIDING WINDOWS. Elegantly simple, classic design. McLachlan Homes

according to Section 4.2 heroal-johann Henkenjohann GmbH & Co. KG Österwieher Str Verl Germany Window system heroal W65

Duco s intrusion-resistant solutions

Duco s intrusion-resistant solutions

duoport PAS The Slide Fitting System with Parallel Action. in windows

Effect of Building Orientation and Window Glazing on the Energy Consumption of HVAC System of an Office Building for Different Climate Zones

Vinyl Windows and Doors

ENERGETIC MONITORING AND OPTIMIZATION OF A SOLAR HOUSE

Product information Additional window element GIL

Thermal performance and air tightness

Thermal Characteristics and Energy Performance of Double Skin. Façade System in the Hot Summer and Cold Winter Zone

AM-55, AM-56) B U I L D I N G P A R T N E R S H I P S F O R E N E R G Y S E C U R I T Y

Project name Gentoo Retrofit Bid 1 Project summary Refurbishment of 2no. Semi Detached houses using Passivhaus principles

Results from the Application of the Maltese Energy Performance Rating of Dwellings in Malta EPRDM Software to a New Block of Apartments

ADJUSTABLE SOLAR SHADING AND HEAT CONSERVATION LOUVRES FOR TRANSPARENT, MULTI-LAYERED GLASS FACADES

Product information Additional window element GIU

Analysis 2: Alternative Thermal Window Design

Product information Roof terrace GEL + VEA/VEB/VEC

WINDOWS & DOORS GSG STRUCTURAL ALL GLASS SYSTEM

Young Cities Research Briefs 07 Architectural Energy Efficiency

Curtainwalls. Brussels Window. Objectives. Windows & Curtainwalls. Curtainwalls. 1 R2 R3. High tech? Low tech?

Transcription:

Page 1 of 5, Building Physics, ift Rosenheim Principles of construction for improving thermal insulation and for preventing condensation The Energy Performance of Buildings Directive (EBPD) 2010 of the EU for new constructions until end 2018 requires the lowest energy performance of buildings standard (nearly zero energy buildings), which is being implemented nationally by the more stringent requirements of the Energy Saving Regulations (EnEV) of 2016. Coupled windows are an optimal option for meeting the more stringent requirements for heat protection in summer and thermal insulation in winter equally. Coupled windows consist of two casement frames with an air space between in which the solar shading can be integrated such that it is protected against weather. The advantage compared to fittings in the inter-pane cavity is that you can separate the two sashes easily in order to clean, maintain or replace the solar shading and anti-glare elements. Moreover, you can also integrate systems for regenerative energy utilisation, e.g. photovoltaic elements. Coupled windows are suitable for maintaining historical urban patterns since the inner sash meets the requirements for heat and sound insulation and the outer sash can be executed according to design specifications. This is why the majority of system providers offer coupled windows and they are a good opportunity for metal builders to offer high-performance systems including solar/glare protection for high-quality public buildings or commercial properties. Figure 1 Modern coupled windows with automatically opening ventilation sashes and integrated solar shading for the refurbished office building of ift Rosenheim

Page 2 of 5 However, there may be condensation forming in the space between the two sashes that is perceived by the building owners as a defect and often leads to complaints and legal confrontations. The following contribution illustrates the correlations at the building physics level as well as construction-related solutions for the same. 1 The "natural" building physics of condensation Condensate formation is a natural phenomenon of building physics that is influenced by the weather conditions, solar shading, incoming flow, occurrence of moisture, cleaning, air conditioning of the rooms, orientation, building height as well as naturally by the window construction. Everyone is aware of condensate on car window panes or as frost with plants. This is caused by the cooling down of the surface below the dew point temperature, which occurs as a result of the large temperature difference in case of a clear and cold night sky between universe and the surfaces near the ground. In this way, the glass surfaces also get cooled down below the ambient atmospheric temperature. If the dew point temperature gets undershot in the process, dew precipitates on the surface. Flat car window panes "see" plenty of sky and cool down quite considerably the same is true of the roof window. Vertical glass panes are not affected so considerably, but nonetheless, with highly thermally insulating constructions, there may be condensate, and in fact, ice forming on the outside of the outer glass pane. Condensate within the space of coupled windows occurs when the air exchange with the outdoor air takes place gradually, especially in combination with double or triple glazing. Figure 2 Change in the temperature difference between the outdoor air temperature and air temperature in the space between the sashes with improved heat insulation.

Page 3 of 5 In the context of the standard, condensed water as such is not a defect, since DIN 4108-2 [3] describes the following in Section 6.1: "Condensate formation is permissible temporarily and in small quantities on windows as well as stick constructions, if the surface does not absorb the moisture and appropriate precautions are taken to prevent contact with neighbouring sensitive materials." Temporary condensate (e.g. frost formation in the morning), but even longer occurrence as a consequence of unfavourable outdoor climate (e.g. still air, high atmospheric humidity, no solar radiation") must be accepted provided that the concerned surfaces and materials are insensitive to moisture, for example, with metal profiles. However, this is not necessarily true for adjacent wall superstructures with insulating or wooden materials. 2 Principles of construction for reducing the risk of condensate The critical season for coupled windows is the transition period when atmospheric humidity and temperature of the outdoor climate is subject to relatively quick change. In this case, condensed water within the construction cannot be avoided. However, it can be minimised with the help of constructive measures, which enable the necessary vapour pressure equalisation from the gap in the sash to the outdoor climate. The equalisation always takes place from the location of the higher vapour pressure to that of the lower and thus, generally to the outside. The simplest opening is that gap on all four sides between both sashes on the outer structural rebate. Recommendations for ventilation of the space between the two sashes are compared in Table 1. DIN EN 6946 specifies a converted gap of 1.5 mm on all four sides for ventilated air layers. In the calculation standard EN ISO 10077-1, the gap on all four sides is limited to 3 mm in order to avoid unnecessary air exchange with the outdoor air that degrades the thermal insulation. Table 1 Recommendations for the gap dimensions for ventilation of the space between the two sashes

Page 4 of 5 In case of integrated sunshade elements, the space between the two sashes gets heated up by absorption of the solar radiation. The heat must get dissipated outside so that the total solar energy transmitted (g value) does not deteriorate with high surface temperatures on the room side and the metal windows do not expand considerably, get deformed and cause damage. If necessary, larger surface areas are necessary here. The function and fitness for use of the construction can be checked easily by a calorimetric measurement, in which all energy and heat flows are recorded and even the surface temperatures can be measured at any point. A gap on all four sides is difficult to implement if additional requirements such as enhanced sound insulation are specified for the building component. The gap can be replaced with offset drilling holes or with a labyrinth between the space and the outdoor air. However, this leads to the fact that the construction rules for the necessary opening face of a joint on all four sides cannot be applied. The functionality of the vapour pressure equalisation system can be checked only by testing the dew point performance by measuring the temperatures and determining the partial vapour pressures. The connection to the room side, in contrast, must necessarily be avoided. In order to ensure functional sealing on the room side, concealed hardware that does not interrupt the sealing level is well suited. Even the most minor leakages lead to failure of the construction; hence, the function of the seal must be checked at the time of production and assembly. Test equipment for determining the air permeability according to EN 1026 is appropriate for this purpose. Figure 3 Evaluation scheme for dew point performance of coupled and double windows Measurement is done with a climatic test rig using the 2-chamber principle, in which the function of the vapour pressure equalisation system is verified. By measuring the values of air temperature and humidity in the space between the two sashes, the partial pres-

Page 5 of 5 sures of water vapour can be determined. You can assume formation of condensed water as soon as the dew point temperature has been undershot. This is also identified and documented with visual assessment. Literature [1] Böttcher, W.; Hartmann, H.-J.; Schmid, J. Untersuchung an Verbundfenstern zur Verbesserung des Wärme- und Schallschutzes bei gleichzeitiger Sicherstellung der übrigen Funktionen, wie Tauwasser usw.. Research report of ift Rosenheim, July 1981 [2] ift Hausverfahren (WÄR11) Prüfung des Tauwasserverhaltens von Elementen (Testing the dew point performance of elements) ift Rosenheim, 2016 [3] DIN 4108-2:2013-02 Thermal protection and energy economy in buildings - Part 2: Minimum requirements to thermal insulation Beuth Verlag GmbH [4] DIN EN ISO 6946:2008-04 Building components and building elements - Thermal resistance and thermal transmittance - Calculation method. Beuth Verlag GmbH, Berlin [5] DIN EN ISO 10077-1:2010-05 Thermal performance of windows, doors and shutters - Calculation of thermal transmittance - Part 1: General. Beuth Verlag GmbH, Berlin