POST-STRENGTHENING OF MASONRY COLUMNS BY USE OF FIBER-REINFORCED POLYMERS (FRP) Abstract

Similar documents
AN IMPROVED COMPOSITE ANCHORING SYSTEM

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

SEISMIC REHABILITATION OF REINFORCED CONCRETE BRIDGE COLUMNS IN MODERATE EARTHQUAKE REGIONS USING FRP COMPOSITES

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

SEISMIC RETROFITTING OF REINFORCED CONCRETE COLUMNS USING CARBON FIBER REINFORCED POLYMER (CFRP)

AFRP retrofitting of RC structures in Japan

Shear force strengthening of large reinforcedconcrete components using textile-reinforced

University of East London Institutional Repository:

Cyclic In-Plane Shear of Concrete Masonry Walls Strengthened by FRP Laminates

SikaWrap. Composite Fabrics for Structural and Seismic Strengthening. Solutions with Sika Systems. Hybrid fiber fabrics. Glass fiber fabrics

Improvement of the seismic retrofit performance of damaged reinforcement concrete piers using a fiber steel composite plate

Experimental Study of Reinforced Concrete (RC) Beams Strengthened by Carbon Fiber Reinforced Polymer (CFRP): Effect of Beam Size and Length of CFRP.

Retrofitting methods

CFRP RETROFIT OF MASONRY WALLS. Abstract

CALIBRATION OF A FE MODEL OF MASONRY WALL RETROFIT BY CFRP (CARBON FIBER REINFORCED POLYMER)

BEHAVIOR OF INFILL MASONRY WALLS STRENGTHENED WITH FRP MATERIALS

Collapse prevention of infill-brick wall of RC frames with FRP Stitching Technology

Use of CFRP in Confining High Strength Concrete Columns Subject to Axial Loading

EXPERIMENTAL INVESTIGATION OF MASONRY PANELS EXTERNALLY STRENGTHENED WITH CFRP LAMINATES AND FABRIC SUBJECTED TO IN-PLANE SHEAR LOAD

ACTIVE CFRP-BASED CONFINEMENT STRATEGIES FOR RC COLUMNS WITH RECTANGULAR CROSS SECTIONS

BEHAVIOR OF REINFORCED CONCRETE ONE-WAY SLABS STRENGTHENED BY CFRP SHEETS IN FLEXURAL ZONE

Dynamic In-Plane Behavior of URM Wall Upgraded with Composites. Abstract. Keywords. Introduction

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

COMPARISON OF IN-SITU AND LABORATORY TESTS OF BRICK MASONRY WALLS STRENGTHENED WITH CARBON FIBRE REINFORCED POLYMER FABRIC

FRP REPAIR TECHNIQUES FOR R.C. BEAMS PRE-DAMAGED IN SHEAR

EFFECT OF EMBEDMENT LENGTH ON THE PERFORMANCE OF SHEAR-STRENGTHENED RC BEAMS WITH L-SHAPED CFRP PLATES

AN INNOVATIVE DUCTILE COMPOSITE FABRIC FOR STRENGTHENING CONCRETE STRUCTURES. Abstract

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

A STUDY ON THE BEHAVIOUR OF RC BEAMS RETROFITTED USING CFRP LAMINATES UNDER SINGLE POINT LOADING

MECHANICAL PROPERTIES OF MASONRY SAMPLES FOR THEORETICAL MODELING

Maximum usable strain of FRP-confined concrete cylinders

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

SHAKING TABLE TEST OF LARGE SCALE NONDUCTILE RC FRAMES RETROFITTED WITH FRP COMPOSITES

FRP Anchorage Systems for Infill Masonry Structures

Enhancing the Compressive Strength of Square Cross Sectional Column Using FRP Material

LOAD TESTS ON 2-SPAN REINFORCED CONCRETE BEAMS STRENGTHENED WITH FIBRE REINFORCED POLYMER

Experimental tests on RC hollow columns strengthened with FRPs

SEISMIC STRENGTHENING OF A PRECAST REINFORCED CONCRETE WALL PANEL USING NSM-CFRP

Behaviour of deviated CFRP-Strips

Analytical study of a 2-span reinforced concrete beam strengthened with fibre reinforced polymer

CONCRETE-FILLED SQUARE FRP TUBES UNDER AXIAL COMPRESSION

SEISMIC RETROFIT OF BEAM-COLUMN JOINTS WITH FRP SHEETS

Strengthening of infilled RC frames by CFRP

FRP-Confinement of Hollow Concrete Cylinders and Prisms

PRESTRESSED CONCRETE PLATES WITH HIGH STRENGTH FABRIC

SEISMIC STRENGTHENING OF INFILLED RC FRAMES BY CFRP

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

Construction. Structural Strengthening with SikaWrap Fabric Systems

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

STRUCTURAL STRENGTHENING WITH FRP AYDIN KHAJEPUR SIKA PARSIAN, TM REFURBISHMENT

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

EXPERIMENTAL DETERMINATION OF INTERFACE SHEAR STESSES SIMULATING THE MIDSPAN AREA OF CONCRETE SLABS POST- STRENGTHENED WITH CFRP STRIPS.

Repair of Earthquake-Damaged RC Columns with FRP Wraps

EXPERIMENTAL STUDY ON REINFORCED CONCRETE COLUMN STRENGTHENED WITH FERROCEMENT JACKET

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

1514. Structural behavior of concrete filled carbon fiber reinforced polymer sheet tube column

CONFINEMENT EFFECT OF FRP AND TRANSVERSE STEEL ON RETROFITTING SQUARE CONCRETE COLUMNS

APPLICATION OF EXPANSIVE AGENT (EA) TO PRODUCE POST TENSIONING FORCE IN FRP JACKETS FOR LATERAL RETROFITTING OF RC COLUMNS

Finite Element Analysis of CFRP Strengthened Concrete Beams

A Numerical Investigation on the Structural Behavior of Deficient Steel Frames Strengthened using CFRP Composite

Effect of Bar-cutoff and Bent-point Locations on Debonding Loads in RC Beams Strengthened with CFRP Plates

Structural behaviour of recycled concrete filled steel tube columns strengthened with CFRP sheets under axial loading

Glass fibre reinforced textile composites strengthening solutions for masonry arches

FE MODELING OF CFRP STRENGTHENED CONCRETE BEAM EXPOSED TO CYCLIC TEMPERATURE, HUMIDITY AND SUSTAINED LOADING

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

Hybrid FRP-concrete-steel double-skin tubular columns: Cyclic axial compression tests

AXIAL TESTING OF CONCRETE COLUMNS CONFINED WITH CARBON FRP: EFFECT OF FIBER ORIENTATION. Abstract

Strengthening of hollow core precast slabs using FRP composite materials procedure, testing and rating

Strengthening Reinforced Concrete Beams Using Hybrid FRP Laminates

Effects Of Slenderness Ratio In RC Slender Column Using GFRP And CFRP Confinement

Enhanced Repair and Strengthening of Reinforced Concrete Beams Utilizing External Fiber Reinforced Polymer Sheets and Novel Anchoring Devices

Residual Seismic Performance of Reinforced Concrete Bridge Piers After Moderate Earthquakes

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

Development of a FRP-Wrapped Spiral Corrugated Tube for Seismic Performance of Reinforced Concrete Columns

RESILIENT INFRASTRUCTURE June 1 4, 2016

13 TH C ANADIAN M ASONRY S YMPOSIUM H ALIFAX, C ANADA JUNE 4 TH JUNE 7 TH 2017 SEISMIC PERFORMANCE OF REINFORCED MASONRY WALLS STRENGTHENED

Upgrading the shear strength of non-ductile reinforced concrete frame connections using FRP overlay systems

IN-PLANE BEHAVIOR OF ALTERNATIVE MASONRY RETROFITTED WITH POLYUREA MEMBRANES

The Effect of Width, Multiple Layers and Strength of FRP Sheets on Strength and Ductility of Strengthened Reinforced Concrete Beams in Flexure

AN ANALYTICAL AND EXPERIMENTAL STUDY ON REINFORCED CONCRETE BEAM WITH CARBON FIBER FABRIC WRAP

EFFICIENCY OF CFRP SHEETS IN UPGRADING AND/OR STRENGTHENING SQUARE REINFORCED CONCRETE COLUMNS

(FRP) ( CFRP

SEISMIC TEST OF CONCRETE BLOCK INFILLED REINFORCED CONCRETE FRAMES

An experimental study on the effect of concrete shrinkage on compressive behaviour of highstrength concrete-filled FRP tubes

EXPERIMENTAL ANALYSIS ON THE SHEAR BEHAVIOUR OF RC BEAMS STRENGTHENED WITH GFRP SHEETS

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

Table of content of printouts:

Structural health monitoring of structures repaired with FRP

LABORATORY TESTS ON MASONRY VAULTS STRENGTHENED AT THE EXTRADOS

Force transfer between existing concrete columns with reinforced concrete jackets subjected to axial loading.

Strategies for concrete confinement with strips of CFRP sheet

1337. Seismic response of beam-column joints rehabilitated with FRP sheets and buckling restrained braces

INNOVATIVE SEISMIC RETROFITTING OF OLD-TYPE RC COLUMNS THROUGH JACKETING: TEXTILE-REINFORCED MORTARS (TRM) VERSUS FIBER-REINFORCED POLYMERS (FRP)

Influence of Arching Mechanism in Masonry Walls Strengthened with FRP Laminates

Strengthening of RC framed structure with masonry infill

IJMTES International Journal of Modern Trends in Engineering and Science ISSN:

Numerical study of in-plane behavior of masonry walls strengthened by vertical CFRP strips

Carbon Fibre Textile

Transcription:

POST-STRENGTHENING OF MASONRY COLUMNS BY USE OF FIBER-REINFORCED POLYMERS (FRP) Cornelia Bieker, University of Kassel, Germany Werner Seim, University of Kassel, Germany Jochen Stürz, University of Kassel, Germany Abstract Within the scope of this paper the test results of post-strengthened masonry columns are presented. Two different types of bricks and two different types of mortars are used to produce the test specimens: vertical coring bricks and solid bricks, calcium cement and calcium mortar. The test specimens are wrapped with two types of fabrics: unidirectional carbon and unidirectional glass tapes with varying numbers of layers. In all cases a thixotropic epoxy system is used as matrix. The paper documents the first results of the load bearing behaviour of the masonry columns. For direct comparison of the load bearing capacity reference columns with the same dimensions and the same brick mortar combinations are tested. The adhesion strength of the carbon sheet on the brick surface was determined by preliminary anchorage tests. Keywords: post-strengthening, masonry, columns, fiber-reinforced-polymers

Introduction Reorganisation, change of use or replanning of industrial buildings might cause changes of structural systems as well as higher life loads. Preservation instead of replacement saves ecological as well as economical resources and even construction time. But in many cases preservation of load bearing structures needs strengthening due to higher stresses. One possibility to strengthen load bearing structures is to apply fiber-reinforced polymers (FRP). For the application on masonry carbon, aramid or alkali-resistant glass fibers can be used as fabric. They are added on the load bearing walls as laminates or sheets. Often epoxy-based resins are used as adhesive. Within the building industry the method of strengthening using FRP was mainly given in concrete construction first. Investigations by using the method of strengthening masonry walls with fiber-reinforced polymers were first realized by Schwegler [1]: based on his results, the load bearing walls of a six story building were strengthened with carbon FRP laminates [2]. Further studies about the strengthening of masonry walls in seismic endangered zones were reported by Ehsani [3,4], Saadatmanesh [5] and Velazquez-Dimas[6]. Different types of carbon fiber and glass fiber sheets were combined with different types of matrices and the position of the sheets on the walls was varied. Laursen [7] tested carbon overlays as retrofit and repair technique to mitigate seismic strength and ductility deficiencies of masonry walls. In-plane and out of-plane tests on one story walls were carried out. The shear and flexural strength of repaired, retrofitted and original masonry walls were analyzed. Triantafillou [8] studied the strength of externally bonded laminates under out-of-plane and in-plane bending and in-plane shear, all combined with axial load. Experimental investigations on post-strengthening of reinforced concrete columns with FRP are reported by Saadatmanesh and Seible [5, 9]. It can be assumed that wrapping techniques should be even more efficient in the case of masonry columns. Therefore, 18 masonry specimens were tested under compression: 10 unstrengthened specimens to study the influence of the specimen geometry on the compression strength and 8 specimens strengthened by wrapping with various amounts of carbon fiber and glass fiber sheets for comparison. Materials Masonry Two types of masonry were obtained using two different types of bricks. The solid bricks (Mz 20), had dimensions of 7,1 cm * 11,5 cm * 24,0 cm. The nominal compression strength was 20 MN/m² with a density of 2,0 kg/dm³. The vertical coring bricks (HLz 12) had dimensions of 11,3 cm * 11,5 cm * 24,0 cm. The compression strength was 12 MN/m² with a density of 0,9 kg/dm³. Two different types of mortar were used: type MG I was a calcium mortar. The compression strength was found to be 1,0 MN/m² after 35-45 days. Type MG II was a calcium - cement mortar with a compression strength of 5,1 MN/m² after 28 days. Brick and mortar materials were selected in order to get a good representation of existing masonry structures in Germany.

50 50 24 24 24 24 a) b) Figure 1. a) Masonry specimen type A, b) Masonry specimen type B, dimensions in cm Fiber-reinforced polymers For strengthening two types of carbon fiber and glass fiber sheets were used in combination with an epoxy-based resin, Figure 2. Table 3 shows the main material parameters as given by the supplier. a) b) Figure 2. a) Unidirectional carbon fiber sheet, b) Unidirectional glass fiber sheet Table 1. Material parameters of sheets and resin [12] Material Carbon fiber sheet Sika Wrap -230C Glass fiber sheet Sika Wrap -430G Resin Sikadur -330 Tensile strength Failure strain Young's modulus [N/mm 2 ] [%] [N/mm 2 ] 3 500 1,5 230 000 2 250 3,1 70 000 30-3 800

Masonry specimens and strengthening Reference specimens In order to form the experimental basis 10 specimens without reinforcement or strengthening were tested as reference. Materials, dimensions and ultimate loads are documented in Table 2 and Figure 3. The compression strength was determined under monotonic loading. The results obtained from Rilem-specimens (Figure 3 and Table 2, geometry 1) were compared with compression strengths of square specimens with the same and the double height. The differences in compression strengths can be interpreted as scattering due to local imperfections of the bricks or the mortar layer. Kirtschig [10] evaluated tests with Rilem-specimens under standardized conditions: dry bricks with the same dimensions, the same mortar strength and the same masonry strength. But even in this case a considerable scatter of test results was reported. 1,4 f c/f c,rilem 1,2 1 0,8 0,6 MZ; MG I HLZ; MG II 0,4 0,2 0 0 1 2 3 Figure 3. Influence of the geometry of the specimens on the compression strength [11], dimensions of the specimens are given in table 2

No. Table 2. Materials, geometries and ultimate loads of the reference specimens MG I Mortar MG II Mz 20 Brick HLz 12 Geometry of test specimens h * w * d [cm] (compared Figure 3) 1 2 3 50*49*11,5 50*24*24 100*24*24 Ultimate load [kn] 1 x x x 250 2 x x x 260 3 x x x 250 4 x x x 360 5 x x x 280 6 x x x 240 7 x x x 210 8 x x x 230 9 x x x 190 10 x x x 200 Post-strengthening of specimens In total 8 masonry specimens were strengthened by wrapping around up to three layers of carbon fiber or glass fiber sheets. Each specimen is identified by a combination of the following characters: the first letter, A or B, refers to the type of masonry. Specimens of type A were made out of solid bricks and a mortar MG I, Type B specimens were made out of vertical coring bricks and a MG II. The last letters and numbers designate the numbers of layers and the fabric which was used, e.g. 1-L C =ˆ one layer carbon fiber sheet. Table 3. Nomenclature of the post-strengthened specimens Test specimen Type A (Mz 20/MG I) Type B (HLz 20/MG II) 1 layer carbon fiber sheet 2 layers carbon fiber sheet 2 layers glass fiber sheet 3 layers glass fiber sheet A/ 1-L C A/ 2-L C A/ 2-L G A/ 3-L G B/ 1-L C B/ 2-L C B/ 2-L G B/ 3-L G The edges of the columns were rounded with a radius of 3 cm to prevent any stress concentrations within the reinforcing layers. Before bonding the sheets mortar was applied to fill and to smoothen the edges. The sheets were applied to the specimen after wetting the brick faces and the sheets with the epoxy. The fabric was wrapped around the column horizontally. The epoxy was forced through

the fabric with a roller before the next layer was applied (Figure 4). The pressing increases the adhesion because entrapped air is pressed out and the wetting of the fibers is improved. The overlap of the sheet in circumferential direction is 10 cm, and there is no lengthwise overlap. Figure 4. Specimens a) type A, b) type B a) b) Test setup Figure 5 presents the test setup used for the compression test. The load was applied by means of a 40 mm steel plate witch was laid in mortar on the column. In order to assure the force acting centrically on the test specimen a hinge was placed between the steel plate and the vertical actuator. The instrumentation for the specimens consists of 4 displacement transducers measuring the compressive deformation on each side of the column. Additionally a strain gauge was attached onto each middle section of the column to record the local strain in circumferential direction. actuator hinge mortar layer strain gauge steel plate test specimen displacement transducer steel plate test bed Figure 5. Test setup

According to strength predictions of the reference tests the columns were loaded in 5 steps up to 150 kn in displacement control. The first level was at 30 kn. After reaching each level the force was held for 90 seconds. Beyond reaching 150 kn the force was increased to the maximum load level. Experimental Results Table 4 presents the ultimate loads of the post-strengthened columns compared to the unstrengthened specimens. For type B masonry ultimate loads of the strengthened specimens were found to be 30 % to 60 % higher compared to unstrengthened specimens. For masonry type a strengthening was even more successful: the compression strength was improved up to 250 % to 300 % through the post-strengthening of the masonry. Table 4. Test results Ultimate load of the Specimens post-strengthened specimens [kn] A/ 1-L C 760 A/ 2-L C 848 A/ 2-L G 690 A/ 3-L G 751 B/ 1-L C 270 B/ 2-L C 300 B/ 2-L G 337 B/ 3-L G 338 Ultimate load of the reference specimen [kn] 250 360 190 230 Solid - brick masonry type A Figure 6 shows the load-strain diagram of the specimen A/ 3-L G. The characteristics of these curves are representative for the behavior of all type A specimens. As to be expected the increase of load results in a linear increase of strain up to a load level of about 250 kn. This point, referred to as internal failure level, is reached when failure of the unstrengthened columns occurs (Table 4). Increasing the load above this level leads to a clearly non-linear behavior of the load-strain relationship. A small increase of load leads to a large increase of strain. Obviously the specimen is in a state of transition caused by subsequent failure. The mechanisms governing this process are not clearly elucidated so far. But it is important to notice that throughout this state and beyond the load can be increased by a factor of three until the structure fails. Final collapse of the specimen occurs at 760 kn initiated by local fiber fracture of the reinforcement (Figure 8). With increasing deformation the load even drops. Figure 7 presents the results of all type A specimens. These results are compared to an unstrengthened reference specimen and show an obvious increase of ultimate load. The overall strain was calculated from the displacement of the machine transducer and the overall height of the specimen; so the values differ from those in figure 6 which were measured over the length of the displacement transducers which were fixed on the composite s surface and therefore represent local values.

The stiffness of the specimen A/ 2-L G is higher than that one of the specimen A/ 3-L G due to the age of the specimens at the time they were tested (A/ 2-LG;144 days, A/ 3-L G: 41 days). 800 700 600 structural failure load in kn 500 400 300 strain gauge 1 strain gauge 2 strain gauge 3 strain gauge 4 disp. trans. 1 disp. trans. 2 200 100 disp. trans. 3 disp. trans. 4 internal failure 0-75 -65-55 -45-35 -25-15 -5 5 left: strain [ ] in load direction (displacement transducer) right: strain [ ] in circumferential direction (strain gauges) Figure 6. Load-strain diagram of the specimen A/ 3-L G 900 800 A/ 2-L C A/3-L G 700 600 A/ 2-L G A/ 1-L C load in KN 500 400 300 200 reference 100 0 0 5 10 15 20 25 30 35 40 strain e in Figure 7. Load-strain curves of the strengthened specimens type A compared to an unstrengthened reference specimen

a) b) Figure 8. a) Specimen A/ 1-LC after failure; b) specimen A/ 3-L G after failure Cored brick masonry type B Figure 9 shows a characteristic which is typical for all type B fiber-wrapped specimens. As expected the increase of load leads to a linear increase of strain in circumferential direction. When the load level reaches 210 kn the internal failure of the masonry is indicated by the flattening of the load-strain curves. The test was stopped at a load level of 270 kn because an increase of load was no longer possible. The vertical coring brick failed far before the tensile capacity of the laminate was reached. 300 250 200 load in kn 150 100 50 strain gauge 1 strain gauge 2 strain gauge 3 strain gauge 4 disp. trans. 1 disp. trans. 2 disp. trans. 3 disp. trans. 4 0-8 -6-4 -2 0 2 4 left: strain [ ] in load direction (displacement transducer) right: strain [ ] in circumferential direction (strain gauges) Figure 9. Load-strain diagram of the specimen B/ 1-L C

450 400 350 300 B/ 3-L G B/ 2-L G load in kn 250 200 150 reference B/ 1-L C B/ 2-L C 100 50 0 0 5 10 15 20 25 30 strain e in Figure 10. Load-strain curves of the post - strengthened specimens type B compared to a reference specimen Figure 10 shows the increase of load bearing capacity compared to the unstrengthened reference specimen. Again strains were calculated from the displacement of the machine transducer and the overall height of the specimen. Even if the level of strengthening ultimate load of a post-strengthened specimen compared to the unstrengthened specimen was not as high as it was in the case of solid-brick masonry the ductility was improved considerably. Summary The results show that the post-strengthening of masonry columns leads to an essential increase of ultimate load and ductility. For vertical coring bricks an increase of 30 % - 60 % can be achieved depending on the stiffness of the reinforcement. Due to the internal geometry of cored bricks the characteristic of failure is substantially different to that of solid bricks, where the load could be increased up to 300 %. More studies are necessary to analyze and complete these first results. Further experimental studies will be complemented by numerical investigations.

References 1. Schwegler, G. (1994); Verstärken von Mauerwerk mit Faserverbundwerkstoffen in seismisch gefährdeten Zonen, Eidgenössische Materialprüfungs- und Forschungsanstalt, Nr. 229 2. Schwegler, G. (1996); Verstärkung von Mauerwerkbauten mit CFK Lamellen, Sonderdruck aus Schweizer Ingenieur und Architekten, Nr. 44 3. Ehsani, M. R. (1995); Strengthening of Earthquake-Damaged Masonry Structures with Composite Material, Proceedings of the Second International RILEM Symposium (FRPRCS-2), Ghent, 680-687 4. Ehsani, M.; Saadatmanesh, H. (1996); Seismic Retrofit of URM Walls with Fiber Composites, The Masonry Society Journal, V 14, No. 2, 63 72 5. Saadatmanesh, H. (1997); Extending service life of concrete and masonry structures with fiber composites, Construction and Building Materials, Vol. 11, Nos. 5-6, 327-335 6. Velazquez-Dimas, J.; Ehsani, M.R.; Saadatmanesh, H. (2000); Out-of-Plane Behaviour of Brick Masonry Walls Strengthened with Fiber Composites, ACI Structural Journal, No. 97, 337-387 7. Laursen, P. T. ; Seible, F.; Hegemier, G. A.; Innamorato, D. (1995); Seismic Retrofit and Repair of Masonry Walls with Carbon Overlays, Proceedings of the Second International RILEM, Ghent, 616-623 8. Triantafillou, T. C. (1998); Strengthening of Masonry Structures using Epoxy-Bonded FRP Laminates, Journal of Composites and Construction, 96-104 9. Seible, F., Priestley, M. J., Hegemier, A. G., Innamorato, D. (1997); Seismic Retrofit of RC Columns with Continuous Carbon Fiber Jackets, ASCE Journal of Composites for Construction, Vol. 1, 52-62 10. Kirtschig, K., Meyer, J. (1988); On the evalution of masonry tests in compression, Proceedings of the 8th International Brick and Block Masonry Conference, Dublin, 1373-1383 11. Stürz, J. (2000); Ziegelmauerwerk mit Mörtelgruppe I und II: Untersuchungen zum Einfluss der Abmessungen des Probekörpers auf die experimentell bestimmte Druckfestigkeit, Diploma thesis, University of Kassel 12. Sika Chemie GmbH: Sika Wrap 430G (VP)/Sikadur-330, Glasfasergewebe-Verstärkungssystem, Sika Wrap 230G (VP)/Sikadur-330, Kohlenstofffasergewebe-Verstärkungssystem, Technische Merkblätter Sika Stuttgart