HP Partial Fill. Robust, long-lasting protection

Similar documents
Fire protection for timber frame & masonry cavity walls

RAINSCREEN DUO SLAB. Non-combustible thermal insulation

TCB & PWCB CAVITY BARRIERS Fire Protection for timber/steel frame & masonry cavity walls

ROCKFLOOR. Thermal and acoustic stone wool insulation for ground and separating floors

SP FIRESTOP VRB Open-state cavity fire barrier for use within building facades

ENERGYSAVER. Blown cavity wall insulation

SP FIRESTOP OSCB 60 & 120 Open-state cavity barrier only for use with RAINSCREEN DUO SLAB

SOFFIT SLAB Thermal, fire and acoustic insulation for concrete soffits

RAINSCREEN CLADDING SOLUTIONS

ROLL, TWINROLL AND ROLLBATT. Thermal loft insulation with added acoustic protection and fire resistance

MULTI-CABLE FIRESTOP Firestop solution for multi-cable penetrations

INTUMESCENT PIPEWRAP ROLL Fire protection for pipework through fire rated walls and floors

Ductslab and Ductwrap

TECHWRAP2 AND TECHTUBE Acoustic solutions for pipework and equipment

Ductslab and Ductwrap

RockLap H&V pipe sections

ACOUSTIC MEMBRANE High performance sound-deadening

FLAT ROOF OVERLAY BOARD Simplifying the repair and refurbishment of flat roof systems

INTUMESCENT PIPE WRAPS Fire stop solution for plastic pipe penetrations

SP FIRESTOP SYSTEMS The purpose-made solution for cavity fire stopping

ACOUSTIC INFILLS High performance sound absorption for perforated metal decks

INTUMESCENT PIPEWRAP ROLL Fire protection for pipework through fire rated walls and floors

RW SEMI-RIGID AND RIGID SLABS (RWA45, RW3, RW4, RW5 & RW6)

ROCKWOOL Tapered Roofing

MULTI-CABLE FIRESTOP Firestop solution for multi-cable penetrations

Product. Regulations. Rockwool Ltd Pencoed Bridgend CF35 6NY Tel: Fax: Agrément Certificate No 93/2884 Second issue*

INTUMESCENT PILLOWS Temporary firestop solution for large voids in walls & floors

LINEAR & TRAPEZOIDAL FIRESTOP SYSTEM Fire stopping solutions at compartment junctions

BEAMCLAD SYSTEMS. Fire protection solutions for structural steel & soffit protection

Owens-Corning Building Products (UK) Ltd P O Box 10 St Helens Merseyside WA10 3NS Tel: Fax:

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

ROCKWOOL External Wall Products for System Holders

FIRE RESISTANT SILICONE SEALANT A high performance fire stopping sealant

DUCTWRAP AND DUCTSLAB For the thermal insulation of ductwork and water storage tanks.

60MM ABLATIVE COATED BATT Fire stopping solution for voids in walls and floors

SOUND INSULATION SLAB A family of fire resilient stone wool insulation products optimised for soundproofing

FIRESTOP COMPOUND Firestop solution for cable, pipe and duct penetrations

ROCKWOOL ABLATIVE COATING Improves the fire resistant properties for ROCKWOOL stone wool slabs

Guide to Enhanced Capital Allowances

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

Floors Walls Roofs. Jabfill Premium. APPLICATION: Full-fill Cavity Wall Insulation PRODUCTS: Vencel Resil Limited

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

ROCKWOOL BUILT IN CAVITY WALL INSULATION BATTS ROCKWOOL CAVITY WALL BATT

50948-RHN Putney. 06 January This document includes: F30. Accessories/ sundry items for brick/ block/ stone walling. Code Section Revision Dated

Superior Performance Phenolic Insulation. SR/CW Insulation for Partial Fill Cavity Walls. Walls AS LOW AS 10/4803

SEPTEMBER construction type cavity barriers. SP Firestop Systems. The purpose-made solution for cavity fire stopping

Jabfill High Performance (HP)

URSA MINERAL WOOL URSA Cavity Batts

APPROVALS. Jabwall has been approved for this application since 1979, and was the first partial-fill insulation product to gain BBA approval.

Superglass Superwall Cavity Wall Batts Installation Guide - Full-Fill

Xtratherm Thin-R Partial Fill Cavity Wall Board (XT/CW Grade)

URSA Cavity Batts URSA GLASSWOOL.

ROCKSILK DRITHERM CAVITY SLAB Isolation de murs à double paroi Kerndämmung. Regulations B3(4) C2(a)(b) L1(a)(i) L2(a)

PIR Insulation XT/CW (T&G) Insulation for Partial Fill Cavity Walls. Walls 08/ /0183

Rockwool Ltd Pencoed Bridgend Mid Glamorgan CF35 6NY Tel: Fax:

Certificate No: EWW620

PRODUCT SHEET 1 CROWN DRITHERM CAVITY SLAB

How glass or rock mineral wool works in a wall or floor cavity

Concrete Soffit Direct Fix

Cavity closers, fire & acoustic stops Thermo-loc standard cavity closers Thermo-loc plus X and plus C cavity closers Thermo-loc

KINGSPAN THERMAWALL TW50 ZERO ODP Isolant en polyurethanne pour murs creux Kerndämmung. Regulations. Certificate.

PRODUCT SHEET 1 SUNDOLITT EPS CAVITY WALL BOARDS

KOOLTHERM K8 CAVITY BOARD Isolant pour murs creux Kerndämmung

Agrément Certificate 18/5560 website: Products Sheet 1

XTRATHERM SAFE-R INSULATION XTRATHERM SAFE-R PARTIAL FILL CAVITY BOARD

PRODUCT SHEET 1 ECOTHERM CAVITY WALL BOARD

Agrément Certificate 95/3212 website: Product Sheet 1

Agrément Certificate 89/2231 website: Product Sheet 2

URSA PARTIAL AND FULL FILL CAVITY WALL INSULATION URSA CAVITY BATT 32 INSULATION

KNAUF INSULATION EARTHWOOL DRITHERM CAVITY SLAB

An introduction to Part L U-values

Light steel frame walls

FIRE BARRIER SYSTEM Preventing the spread of fire and inhibiting the passage of smoke in concealed spaces

ISOVER CAVITY WALL INSULATION CWS 36, CWS 34 AND CWS 32 FULL FILL CAVITY WALL SLABS

Best Prac ce Guide No. 2. (Version 1 April 2015) Design and Installa on guidelines for par al fill cavity wall boards

JAN Firestopping Standard Details

wall TW50 zero ODP PARTIAL FILL CAVITY WALL INSULATION For more information on Kingspan Insulation visit

Agrément Certificate 10/4803 website: Product Sheet 2

Isover Installation Guide

FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.

FIREPRO FIRE DUCT SYSTEMS Single layer fire protection for rectangular, circular and oval ducts.

Guidance on U Values from Domestic Heating Design Guide

June Non - Residential New Build Masonry cavity walls

August 2008: Issue 1. Non - Residential New Build Masonry Cavity Walls

RECTICEL INSULATION RECTICEL EUROWALL +

URSA TF Roll URSA GLASSWOOL.

CI/SfB (2-) Rn7 (M2) Full Fill Cavity Wall Specification Guide

Built-up metal walls. Built-up metal wall design. 3.3 Built-up Metal Walls

TECHNICAL. Cavity Wall Partial - Fill Insulation. Stylite.

CELOTEX INSULATION CELOTEX CF5000 PIR INSULATION FOR FULL FILL CAVITY WALLS

robustdetails E-FC-6 Separating Floor Concrete Separating Floors Concrete E-FC-6 SYSTEM INSTALLATION

A Handbook of thermal bridging details incorporating aircrete blocks

Why party wall insulation is required

Rockwool Blown Cavity Wall Insulation System

BALLYTHERM PARTIAL FILL CAVITY WALL INSULATION BALLYTHERM BTCW CAVITY WALL INSULATION

Thermally Broken Lintel Product Selector

ALREFLEX RANGE OF CAVITY WALL INSULATION AND CAVITY RAIN BARRIERS ALREFLEX 2L2, ALREFLEX 2L1 AND ALREFLEX 2L2 SUPER R CLASS 0

BALLYTHERM BTCW TONGUE-AND-GROOVE CAVITY WALL INSULATION Isolant pour murs creux Kerndämmung. Regulations. Certificate. Certificate.

K8 Cavity Board. Insulation PARTIAL FILL CAVITY WALL INSULATION P E R F O R M A N C E BBA BRITISH

JABLITE FULL-FILL CAVITY WALL INSULATION JABFILL PREMIUM

Transcription:

1 CONSTRUCTION TYPE: cavity walls HP Partial Fill Cavity Walls Robust, long-lasting protection HP Partial Fill slabs have a robust outer surface, designed to withstand on-site rigours and maintain a clearly defined cavity. The resilient rear surface absorbs irregularities in the inner leaf eliminating stand off and maximising thermal performance. The following NBS clauses include : F30:12, F30:151

2 CONSTRUCTION TYPE: cavity walls Made of renewable stone wool fibres, HP Partial Fill slabs further maximise energy efficiency by knitting together when tightly butt jointed to eliminate gaps. offers a stable and durable solution that will last for the lifetime of the building. Advantages Robust front-face resists damage Slabs knit together to eliminate gaps Maximises thermal performance Water repellent Can be used in high-rise buildings Standards and approvals High Performance Partial Fill Cavity Slabs comply with the requirements of BS EN 13162 Thermal insulation products for buildings Factory made mineral wool products. Fire classification is deemed non-combustible and achieves a reaction to fire classification of A1 (BS EN 13501-1). BBA Certificate s have been laboratory and site tested by BBA and awarded Certificate 93/2884. Use in tall buildings The BBA Certificate permits the product to be used in buildings up to and including 25 metres in height. 1. Buildings up to and including 12 metres: a) The product can be used in any exposure zone where a residual cavity width of 50mm or greater is maintained. However, the use of the product does not preclude the need to apply any external render coat or other suitable finish in severe exposure zones where such application would be normal practice. b) The minimum residual cavity width to be maintained during construction must be 25mm. To achieve this requirement, a greater nominal residual cavity width may need to be specified at the design stage to allow for inaccuracies inherent in the building process (a residual cavity nominally 50mm wide will be required by the NHBC where normal standards of tolerance and workmanship are adopted). 2. Buildings over 12 metres and up to and including 25 metres: The width of the residual clear cavity to be achieved should be a minimum of 50mm, and the following requirements apply: a) From ground level, the maximum height of continuous cavity walls must not exceed 12 metres. b) Above 12 metres, the maximum height of continuous cavity walls must not exceed 7 metres. c) In both cases breaks should be in the form of continuous horizontal cavity trays discharging to the outside. d) Where the cavity width is reduced for structural reasons, e.g. by the intrusion of ring beams, a minimum residual cavity width of 25mm must be maintained and extra care must be taken with fixings and weatherproofing, e.g. the inclusion of a cavity tray. e) The exposure index should not exceed 120. Please note: For buildings over 25 metres in height it is necessary for the designer to submit detail drawings to the BBA for assessment and approval prior to construction. Packaging s are very light and easy to handle. They are supplied compression wrapped in polyethylene which provides short term protection. For long-term protection, they should be stored indoors or under waterproof covering. Dimensions s are produced in 1200 x 455mm to suit a vertical wall-tie spacing of 450mm. The slabs are available in standard thicknesses of 50, 80, 100, 120 and 135mm.

3 CONSTRUCTION TYPE: cavity walls s has a thermal conductivity of 0.034 W/mK. Approved Document L (2013 edition England and 2014 Wales) requirements for walls: New build dwellings: England 0.25-0.18W/m²K Wales 0.21-0.18W/m²K New build non-domestic: England 0.26-0.22W/m²K Wales 0.26-0.22W/m²K Extensions to dwelling: England 0.28W/m²K Wales 0.21W/m²K Extensions to non-domestic: England 0.28W/m²K Wales 0.26W/m²K Table 1 - examples Inner block W/mK Int finish HP Partial Fill (mm) Medium dense 1400-1450kg/m 3 0.470W/mK Light plaster P/board on dab Aircrete Hi Strength 750kg/m 3 0.190W/mK Light plaster P/board on dab 80 0.31 0.31 0.30 0.29 0.29 0.28 100 0.28 0.27 0.26 0.25 0.25 0.24 120 0.24 0.23 0.23 0.22 0.22 0.21 135 0.22 0.21 0.21 0.20 0.20 0.18 150 0.20 0.19 0.19 0.18 0.19 0.18 ROCKWOOL HP Partial Fill Cavity Slab Aircrete Std 600kg/m 3 0.150W/mK Light plaster P/board on dab Specification clause The partial fill cavity wall insulation is to be... mm* thick ROCKWOOL s manufactured by Rockwool Limited, Bridgend, installed as work proceeds in accordance with the requirements of BBA Certificate 93/2884. * insert thicknesses required Fix securely to inner leaf in accordance with Rockwool s and BBA Certificate recommendations Slabs to be fixed with the robust (patterned) face outwards Design guidance The following guidance regarding wall ties is given in good faith and is not intended to override any good practice recommendations (refer also to BBA Certificate 93/2884, copies of which can be downloaded from www.rockwool.co.uk). Designing the cavity wall The outer leaf is the first line of defence against rain and the following will help to improve its effectiveness: 1. Before designing the width of the cavity, consider the dimensional tolerances of the components which make up the wall and the width of the residual airspace. 2. Specify weather-struck, flush or bucket handle joints. Recessed joints increase the risk of water penetration in high exposure zones. Ensure that all bed and perpend joints in the external wall are fully filled with mortar. 3. Vertical damp proof courses at wall openings should project at least 25mm into the cavity. 13mm plaster or 12.5mm plasterboard on dabs (see Table 1)

4 CONSTRUCTION TYPE: cavity walls Wall ties Wall ties should be built into each leaf with a minimum embedment of 50mm. However, some manufacturers recommend an embedment of 62.5mm to allow for site tolerances. Drip features on a wall tie should be placed at the centre of an open cavity. Figure 1. Wall tie between slabs with retaining clip Insulation retaining clips The specifier must ensure that the retaining clips used are suitable for the selected wall tie. Minimising thermal bridging at door and window openings See Rockclose fire resistant cavity closer data sheet. Figure 2. Plan view at jamb, showing Rockwool Rockclose with frame in rebated check reveal. Installation The walls should be constructed with the inner leaf leading, with fastened to the cavity face of the inner leaf. For optimum performance, the cavity slabs should be placed with the patterned face outwards. Procedure 1. A section of the inner leaf should be built with the first row of wall ties at approximately 600mm horizontal spacing where the insulation is to begin. It is recommended that the wall ties are not placed directly on the damp-proof course. 2. The first run of slabs should commence below the damp-proof course level to provide overlap edge insulation at the floor interface. 3. The inner leaf should be built up to the required height, with wall ties placed at a vertical height of 450mm. Excess mortar should be cleaned from the cavity face of the leading leaf and the slabs compressed slightly between the upper and lower wall ties behind the retaining clips. This is to form a closely butt-joined run. 4. The second row of wall ties should be fitted to retain the tops of the slabs. It is essential that all wall ties slope downwards towards the outer leaf and at centres not exceeding 600mm to ensure that each slab is secured at a minimum of four points (see figure 3). 5. Additional ties may be required to satisfy the structural requirements and/or to ensure adequate retention of slabs or cut pieces. Alternatively, the slabs can be retained against the leading leaf using mechanical fixings with 70mm diameter washers. 6. Complete successive sections of wall up to the roof line.

5 CONSTRUCTION TYPE: cavity walls Figure 3. Wall tie and retaining clip pattern Figure 5. Use of cavity board Please note: This wall tie stagger pattern ensures that no more than 450mm of slab overhangs a fixing. Advisory notes 1. All areas of the wall must be insulated do not leave gaps. Ensure that the patterned side faces outwards. 2. Close butt the slabs at all horizontal and vertical joints. Cut them carefully to fit around any protrusions into the cavity. 3. Close butt joints at corners, being careful not to bend the slabs. 4. Clean off excess mortar from the cavity face of the wall before installing the slab. 5. Do not allow mortar to drop on top of the slabs that are positioned in the cavity. Protect the top of the slabs with a batten during installation. 6. Do not allow mortar to drop into the cavity. After each section of the inner leaf is built, excess mortar should be removed from the cavity face and mortar droppings cleaned from any exposed edges of the installed board. This should take place before the installation of the next run of boards. A cavity batten will protect the installed boards and helps keep the cavity clean as the outer leaf is built up (see figure 4). 7. Where cut slabs of less than full length are installed, a minimum of 2 retaining washers should be provided to support the lower edge of the slab.

6 CONSTRUCTION TYPE: cavity walls Sustainability As an environmentally conscious company, ROCKWOOL promotes the sustainable production and use of insulation and is committed to a continuous process of environmental improvement. Environment Made from a renewable and plentiful naturally occuring resource, ROCKWOOL insulation saves fuel costs and energy in use and relies on trapped air for its thermal properties. ROCKWOOL insulation does not contain (and has never contained) gases that have ozone depletion potential (ODP) or global warming potential (GWP). All ROCKWOOL products provide outstanding thermal protection as well as four added benefits: Fire resistance Acoustic comfort Sustainable materials Durability Health & Safety The safety of ROCKWOOL stone wool is confirmed by current UK and Republic of Ireland health & safety regulations and EU directive 97/69/EC:ROCKWOOL fibres are not classified as a possible human carcinogen. A Material Safety Data Sheet is available and can be downloaded from www.rockwool.co.uk to assist in the preparation of risk assessments, as required by the Control of Substances Hazardous to Health Regulations (COSHH). ROCKWOOL is approximately 97% recyclable. For waste ROCKWOOL material that may be generated during installation or at end of life, we are happy to discuss the individual requirements of contractors and users considering returning these materials to our factory for recycling. Interested? For further information, contact the Technical Solutions Team on 0871 222 1780 or email info@rockwool.co.uk Visit www.rockwool.co.uk to view our complete range of products and services. Copyright ROCKWOOL April 2014 ROCKWOOL Limited Pencoed Bridgend CF35 6NY info@rockwool.co.uk www.rockwool.co.uk ROCKWOOL Limited reserves the right to alter or amend the specification of products without notice as our policy is one of constant improvement. The information contained in this data sheet is believed to be correct at the date of publication. Whilst ROCKWOOL will endeavour to keep its publications up to date, readers will appreciate that between publications there may be pertinent changes in the law, or other developments affecting the accuracy of the information contained in this data sheet. The above applications do not necessarily represent an exhaustive list of applications for Rockwool. ROCKWOOL Limited does not accept responsibility for the consequences of using Rockwool HP Partial Fill Cavity Slab in applications different from those described within this data sheet. Expert advice should be sought where such different applications are contemplated, or where the extent of any listed application is in doubt.