SOUTH AUSTRALIAN DEMAND FORECASTS SOUTH AUSTRALIAN ADVISORY FUNCTIONS

Similar documents
NATIONAL ELECTRICITY FORECASTING REPORT FOR THE NATIONAL ELECTRICITY MARKET

GENERATION EXPANSION PLAN FOR THE 2014 NATIONAL TRANSMISSION NETWORK DEVELOPMENT PLAN

ECONOMIC OUTLOOK 2015 NATIONAL ELECTRICITY FORECASTING REPORT

DEMAND SIDE PARTICIPATION 2016 NATIONAL ELECTRICITY FORECASTING REPORT

CHAPTER 2 - DEFINITIONS, PROCESS AND METHODOLOGY. 2.1 Key definitions of energy and maximum demand

WEM Demand Forecasting Methodology. October Issues Paper

SOUTH AUSTRALIAN RENEWABLE ENERGY REPORT SOUTH AUSTRALIAN ADVISORY FUNCTIONS

SOUTH AUSTRALIAN RENEWABLE ENERGY REPORT SOUTH AUSTRALIAN ADVISORY FUNCTIONS

SOUTH AUSTRALIAN ELECTRICITY REPORT SOUTH AUSTRALIAN ADVISORY FUNCTIONS

WIND AND SOLAR FARMS TESTING REQUIREMENTS FOR CONTINGENCY FCAS REGISTRATION

SOUTH AUSTRALIAN ELECTRICITY MARKET ECONOMIC TRENDS REPORT SOUTH AUSTRALIAN ADVISORY FUNCTIONS

National Electricity Market Demand Forecasting Methodology. November Issues Paper

SOUTH AUSTRALIAN HISTORICAL MARKET INFORMATION REPORT SOUTH AUSTRALIAN ADVISORY FUNCTIONS

FAST-START INFLEXIBILITY PROFILE PROCESS DESCRIPTION

ELECTRICITY STATEMENT OF OPPORTUNITIES For the National Electricity Market

CLARIFICATION OF GENERATOR TECHNICAL PERFORMANCE REQUIREMENTS (S5.2.5)

DEMAND TERMS IN EMMS DATA MODEL

NATIONAL ELECTRICITY MARKET GUIDE TO GENERATOR EXEMPTIONS & CLASSIFICATION OF GENERATING UNITS

Demand Terms in EMMS Data Model

NEM EVENT - DIRECTION TO SOUTH AUSTRALIA GENERATOR - 9 FEBRUARY 2017

TRIP OF ERARING POWER STATION No. 1 GENERATOR TRANSFORMER AND ERARING VALES POINT 330 KV LINE ON 31 JANUARY 2018

Renewable Energy Index. February 2018

QUEENSLAND COMPETITION AUTHORITY

Impact of small solar PV on the NSW wholesale electricity market. Approved for Public Release 12 October 2017

HEATWAVES AND ELECTRICITY SUPPLY

Demand and Energy Forecasting Forum April 2017

RECOMMENDED TECHNICAL STANDARDS FOR GENERATOR LICENSING IN SOUTH AUSTRALIA ADVICE TO ESCOSA

MEDIUM TERM PASA PROCESS DESCRIPTION

NATIONAL GAS FORECASTING REPORT FOR EASTERN AND SOUTH-EASTERN AUSTRALIA

Renewable Energy Index. December 2018

CHAPTER 2 Energy and demand projections

Modelling of Australia s National Energy Guarantee

Mr Craig Price Group Manager, Planning Australian Energy Market Operator GPO Box 2008 Melbourne VIC 3001

South Australia experienced a mild summer with only a few days exceeding 40 C. A relatively short heat wave occurred in late January 2011.

ISSUE to

Renewable Energy Index. October 2018

SECTION 1. EXECUTIVE SUMMARY

Renewable Energy Index. January 2018

Jemena Electricity Networks (Vic) Ltd

Renewable Energy Index. December 2017

Victorian reactive power support May 2018

FORECASTS AND KEY INFLUENCING FACTORS FOR GRID SUPPLIED ENERGY

SOLAR REPORT JANUARY 2018

REVIEW 2018 RESIDENTIAL ELECTRICITY PRICE TRENDS REVIEW FINAL REPORT 21 DECEMBER Australian Energy Market Commission

Projections of uptake of small-scale systems

2 November Project Manager Queensland Renewable Energy Expert Panel PO Box 15456, City East Queensland Online:

Electricity Statement of Opportunities June 2018

BEFORE THE FLORIDA PUBLIC SERVICE COMMISSION DOCKET NO EI

Interim Emissions Reduction Targets for Victoria ( )

Addressing reliability requirements in the Flemington substation load area

DEMAND SIDE PARTICIPATION INFORMATION GUIDELINES

Ancillary Service. the WEM System Management. June 2018

Renewable Energy Index Benchmark Report

Demand Turn Up (DTU) Interactive Guidance document and invitation to tender

Western Australia electricity price trends

Renewable Energy Index. April 2018

Meridian Energy presentation to UBS Australasia Conference

SOLAR REPORT QUARTER 3, 2018

Australia s renewable energy industry

ELECTRICITY STATEMENT OF OPPORTUNITIES FOR THE NATIONAL ELECTRICITY MARKET

Summer operations November 17

Benefits of Interconnector Upgrades in a Transforming Electricity Sector in South Australia

Review of AEMO s 2013 National Electricity Forecasts

Assessment of Load Factor as a System Efficiency Earning Adjustment Mechanism

Solar PV Capacity Additions Forecast for PJM States:

SOLAR REPORT QUARTER 1, 2018

DATA AND MODEL REQUIREMENTS FOR GENERATING SYSTEMS OF LESS THAN 30 MW

Re: RIT-T Market Modelling, high level review. Introduction & background. June Mr R Korte, Executive Manager Asset Management

ADVICE TO COMMONWEALTH GOVERNMENT ON DISPATCHABLE CAPABILITY

Semi-Scheduled Generation Dispatch Self-Forecast - Assessment Procedure Consultation. December Final Determination

SOUTH AUSTRALIA VICTORIA (HEYWOOD) INTERCONNECTOR UPGRADE

3 May 2012 Issue 13. What is driving the decline in electricity demand?

PRELIMINARY REVENUE PROPOSAL

Energy and demand projections

WEM OPERATIONAL CONTINGENCIES VERSION 3.0

Australia s Climate Policy Options: A Study of Policy Options for the Energy Networks Association Preliminary results

Electricity Market Design Principles

Calculation of the Cost of Energy

South Australian Energy Transformation RIT-T: Project Specification Consultation Report and Market Modelling Approach and Assumptions Report

Distributed Generation

ELECTRICITY TRANSMISSION USE OF SYSTEM PRICES 1 JULY 2015 TO 30 JUNE 2016

South Australia Energy Transformation

2. Germany Solar Feed-in Tariffs (FiT) Present Status and Impact Germany Solar PV On-Grid and Off-Grid Cumulative Installed Capacity,

Supporting Documentation A Changing Industry and Marketplace 0

SA to NSW Interconnector

National Energy Emissions Audit Electricity Update. July Providing a comprehensive, up-to-date indication of key electricity trends in Australia

STTM AND DWGM PARAMETER REVIEW - FINAL REPORT

Demand based network tariffs offering a new choice

MODELLING THE MARKET IMPACT OF BATTERY STORAGE IN ASIA-PACIFIC ELECTRICITY MARKETS

VALUE OF CUSTOMER RELIABILITY REVIEW FINAL REPORT

Queensland Renewable Energy Expert Panel Issues Paper

PREPARED FOR: ARIZONA PUBLIC SERVICE Updated Solar PV Value Report

WESTERN VICTORIA RENEWABLE INTEGRATION PROJECT SPECIFICATION CONSULTATION REPORT

Watt on a hot tin roof

Challenges Facing NSW Energy Markets and Potential Policy Response

3.2 Energy efficiency and renewable energy

SINGLE INDUSTRY SPOKESPERSON PROTOCOL FOR ELECTRICITY IN VICTORIA

ABC AND AGC INTERFACE REQUIREMENTS TECHNICAL SPECIFICATION

ELECTRICITY CONSUMPTION OF SMALL CUSTOMERS IN SOUTH AUSTRALIA

Conventional delivery of services is being upended across industry sectors by technology and customer preferences.

Transcription:

SOUTH AUSTRALIAN DEMAND FORECASTS SOUTH AUSTRALIAN ADVISORY FUNCTIONS Published: July 2017

IMPORTANT NOTICE Purpose The South Australian Advisory Functions are independent reports prepared by the Australian Energy Market Operator (AEMO) and published for the South Australian jurisdiction under Section 50B of the National Electricity Law. Under these provisions, the South Australian Government may also request AEMO to undertake additional advisory functions for the South Australian Declared Power System. The purpose of this report is to provide insights into operational consumption and demand forecasts in the South Australian region of the National Electricity Market. Disclaimer This report contains data provided by or collected from third parties, and conclusions, opinions, assumptions or forecasts that are based on that data. AEMO has made every effort to ensure the quality of the information in this report but cannot guarantee that information, forecasts and assumptions are accurate, complete or appropriate for your circumstances. This report does not include all of the information that an investor, participant or potential participant in the National Electricity Market might require, and does not amount to a recommendation of any investment. Anyone proposing to use the information in this report (including information and reports from third parties) should independently verify and check its accuracy, completeness and suitability for purpose, and obtain independent and specific advice from appropriate experts. Accordingly, to the maximum extent permitted by law, AEMO and its officers, employees and consultants involved in the preparation of this report: make no representation or warranty, express or implied, as to the currency, accuracy, reliability or completeness of the information in this publication; and are not liable (whether by reason of negligence or otherwise) for any statements, opinions, information or other matters contained in or derived from this publication, or any omissions from it, or in respect of a person s use of the information in this publication. Acknowledgement AEMO acknowledges the support, co-operation and contribution of all participants in providing data and information used in this publication. Version control Version Release date Changes 1 14 July 2017 The material in this publication may be used in accordance with the copyright permissions on AEMO s website. Australian Energy Market Operator Ltd ABN 94 072 010 327 www.aemo.com.au info@aemo.com.au NEW SOUTH WALES QUEENSLAND SOUTH AUSTRALIA VICTORIA AUSTRALIAN CAPITAL TERRITORY TASMANIA WESTERN AUSTRALIA

CONTENTS 1. INTRODUCTION AND KEY FINDINGS 4 1.1 Key findings 4 1.2 Key definitions 4 1.3 Rooftop PV methodology 5 2. OPERATIONAL CONSUMPTION 6 2.1 Key differences between 2017 and 2016 forecasts 6 2.2 Forecasts 6 3. MAXIMUM DEMAND FORECASTS 9 3.1 Key differences between 2017 and 2016 NEFR forecasts 9 3.2 Forecasts 9 4. MINIMUM DEMAND FORECASTS 11 4.1 Key differences between 2017 and 2016 NEFR forecasts 11 4.2 Forecasts 11 TABLES Table 1 Actual annual operational consumption for South Australia, 2011 12 to 2016 17 (GWh) 7 Table 2 Forecast annual operational consumption for South Australia (all scenarios), 2016 17 to 2026 27 (GWh) 7 Table 3 Summer operational maximum demand forecasts for South Australia, 2016 17 to 2026 27 (Neutral scenario, MW) 9 FIGURES Figure 1 Annual operational consumption actual and forecast for South Australia (all scenarios), 2007 08 to 2026 27 7 Figure 2 Annual operational consumption forecast by segment for South Australia (Neutral scenario), 2007 08 to 2026 27 8 Figure 3 Summer operational maximum demand forecasts for South Australia, 2007 08 to 2026 27 (Neutral scenario) 10 Figure 4 Summer 10% POE maximum demand forecast segments for South Australia, 2016 17 to 2026 27 (Neutral scenario) 10 Figure 5 Summer 90% POE minimum demand forecast segments for South Australia, 2016 17 to 2026 27 (Neutral scenario) 12 AEMO 2017 3

1. INTRODUCTION AND KEY FINDINGS This report summarises South Australia s electricity demand forecasts, based on the work of the 2017 Electricity Forecasting Insights. 1 1.1 Key findings In the short term (2016 17 to 2019 20), AEMO forecasts a slight decrease in operational consumption in South Australia due to households and businesses managing their use and costs through ongoing investments in rooftop photovoltaic (PV) 2 and energy efficiency, along with a short-term reduction resulting from the announced closure of the automotive industry over the next couple of years. 3 In the medium term (2019 20 to 2026 27), operational consumption in South Australia is forecast to remain relatively flat, due to forecasts of: A slight increase in business consumption driven by projected economic growth in the medium term, moderated by ongoing investments in rooftop PV and energy efficiency. A reduction in residential consumption, with growth in population as well as growth in ownership and use of electric appliances expected to be more than offset by continuing high uptake of rooftop PV and ongoing energy efficiency improvements. Maximum demand is also expected to remain flat, driven by projected increases in rooftop PV and battery storage, and energy efficiency improvements. The minimum demand forecast highlights the impact of rooftop PV on the daily load profile. This provides useful information on network usage, which can inform further studies to evaluate operational implications. By 2027 28, just outside the 10-year window considered by this report, continued uptake of rooftop PV is projected to result in negative minimum demand in South Australia under certain conditions. This may introduce operational challenges for balancing the power system. The power system and market will need to evolve to address these challenges, including utilising the opportunities from new technologies. For example, South Australia could store this excess generation, or could export it to the rest of the NEM via the interconnectors, provided they are in service. 1.2 Key definitions This report presents annual operational consumption as well as operational maximum and minimum demand for historical results, estimates, and forecasts. Consumption refers to electrical energy needed over a period of time and is measured in gigawatt hours (GWh), where demand refers to electrical power needed at a particular point in time (or the average over a short period of time like five or 30 minutes) and is measured in megawatts (MW). This report generally considers consumption or demand over particular reporting periods such as a financial year, summer, or winter. Annual operational consumption includes electricity drawn from the electricity grid, supplied by scheduled, semi-scheduled, and significant non-scheduled generating units, but not generation from rooftop PV and other non-scheduled generation (ONSG). 4 When reporting on a particular NEM region, it includes net interconnector imports from other regions. 1Available at: http://www.aemo.com.au/electricity/national-electricity-market-nem/planning-and-forecasting/electricity-forecasting-insights. 2 Rooftop PV means a system comprising one or more PV panels, installed behind the meter on a residential or commercial building rooftop to convert sunlight into electricity. 3 ABC News, Toyota to close: Thousands of jobs to go as carmaker closes Australian plants by 2017 (2014). Available at: http://www.abc.net.au/news/2014-02-10/toyota-to-pull-out-of-australia-sources/5250114. Viewed: 27 June 2016. 4 Rooftop PV and ONSG generally covers generators smaller than 30 MW. In the 2016 report, ONSG was referred to as SNSG (small nonscheduled generation). AEMO 2017 4

Underlying consumption or demand means actual electricity used by consumers, as met by any kind of generation, including rooftop PV. Delivered consumption or demand means electricity delivered to consumers from the grid (thus, underlying demand less electricity generated from rooftop PV). Annual operational consumption and operational maximum (minimum) demand are both presented on a sent out basis, measured at the connection point between the generating system and the network, and exclude generator auxiliary loads (electricity used by the generator in its own operations). A probability of exceedance (POE) refers to the likelihood that a maximum demand or minimum demand forecast will be met or exceeded. The various probabilities (generally 90%, 50%, and 10% POE) provide a range of possibilities for analysts to determine a realistic range of power system and market outcomes. For a given period, a 10% POE maximum demand forecast is expected to be exceeded, on average, one year in 10 and a 50% POE projection is expected to be exceeded, on average, five years in 10 (or one year in two). Minimum demand forecasts are based on a 90% POE, which are expected to be met or exceeded, on average, nine years in 10 (meaning the actual demand is expected to be below the forecast minimum only, on average, one year in 10). 1.3 Rooftop PV methodology AEMO s forecast of installed capacity for rooftop PV and battery storage is based on advice from external consultancy Jacobs. 5 To calculate electricity generation from the installed PV capacity, AEMO then used the following steps: Based on the average age of panels in each forecast year, AEMO calculated the effective capacity taking into account the projected degradation of rooftop PV over time. AEMO calculated nominal PV generation traces (half-hourly megawatt hour (MWh) generation per MW of effective PV capacity) based on an approach it developed jointly with the University of Melbourne. 6 Two traces were developed, reflecting generation from north-facing panels and west-facing panels. AEMO used these two traces to calculate a blended trace, which captured an assumed westerly shift in rooftop panel orientation, commencing from zero at the start of 2016 17 and resulting in 10% of Jacobs capacity projections having a westerly panel orientation by 2036 37, in response to changing consumer incentives. 5 Jacobs consultancy report Projections of uptake of small-scale systems is available on AEMO s website: https://www.aemo.com.au/- /media/files/electricity/wem/planning_and_forecasting/esoo/2017/2017-wem-esoo-methodology-report---projections-of-uptake-of-smallscale-systems.pdf. 6 See University of Melbourne s Rooftop PV model - technical report, available on AEMO s website: http://www.aemo.com.au/- /media/files/electricity/nem/planning_and_forecasting/nefr/2016/uom-rooftop-pv-model-technical-report.pdf. AEMO 2017 5

2. OPERATIONAL CONSUMPTION Annual consumption is forecast to remain basically flat over the next ten years in the Neutral scenario, increasing slightly from 12,543 GWh in 2016 17 to 12,866 GWh in 2026 27, an annual average increase of 0.26%: For residential consumption, households seeking to manage their energy use and costs, with projected continued high uptake of rooftop PV and energy efficiency savings, is forecast to more than offset moderate new connections growth and increasing appliance use by households. For the business sector, mild growth in consumption is expected in the longer term, driven largely by industrial investment and increased growth in the other business 7 sector. The growth in business sector delivered demand is forecast to be moderated by businesses managing their use and costs through increased generation from rooftop PV and greater energy efficiency, and, in the short term, by the announced closure of the Australian automotive vehicle manufacturing sector over the next couple of years. In comparison, from 2011 12 to 2016 17, annual operational consumption declined by 740 GWh, an average annual decline of 1.1% over the five years. This is primarily attributed to increasing uptake of rooftop PV and energy efficiency measures. 2.1 Key differences between 2017 and 2016 forecasts The key differences are: The current estimate for 2016 17 annual operational consumption is 12,543 GWh, which is 84 GWh (0.7%) below the 2016 National Electricity Forecasting Report (NEFR) Neutral forecast for 2016 17. The 2017 short-term forecast (2016 17 to 2019 20) shows slight growth, compared to the 2016 forecast which projected an average annual decrease of 0.5% in the first two years. 2.2 Forecasts To address the uncertainty of key drivers behind electricity consumption, AEMO publishes forecasts for three scenarios representing weak, neutral, and strong economic and consumer outlooks. 8 The scenario definitions are consistent with those used in last year s report and are summarised in Table 1. Table 1 AEMO s 2017 forecasting and planning scenarios Driver Weak scenario Neutral scenario Strong scenario Population growth Weak Neutral Strong Economic growth Weak Neutral Strong Technology uptake (rooftop PV, energy efficiency, electric vehicles) Slow Hesitant consumer in a weak economy Moderate Neutral consumer in a neutral economy Rapid Confident consumer in a strong economy Annual consumption forecasts are summarised in Tables 2 and 3, and in Figures 1 and 2. 7 The other business sector comprises domestic market servicing industries such as education, financial services, IT, infrastructure, and health and aged care. Growth and consumption trends in this sector are driven by population growth and household disposable income. 8 The three sensitivities all assume Australia achieves its commitment at the 21st Conference of the Parties for the United Nations Framework Convention on Climate Change to reduce greenhouse gas emissions by between 26% and 28% below 2005 levels by 2030. For more see: https://www.aemo.com.au/-/media/files/electricity/nem/planning_and_forecasting/ntndp/2017/draft-2017-planning-and-forecastingscenarios.pdf. AEMO 2017 6

Annual Operational Consumption (GWh) SOUTH AUSTRALIAN DEMAND FORECASTS Table 2 Actual annual operational consumption for South Australia, 2011 12 to 2016 17 (GWh) Financial year GWh % change 2011 12 13,367 2012 13 13,319-0.4% 2013 14 12,872-3.4% 2014 15 12,468-3.1% 2015 16 12,966 4.0% 2016 17 (estimate) 12,543-3.3% Table 3 Forecast annual operational consumption for South Australia (all scenarios), 2016 17 to 2026 27 (GWh) Financial year Actual Weak Neutral Strong 2016 17 (estimate) 12,543 2017 18 11,925 12,308 12,521 2018 19 12,035 12,270 12,572 2019 20 12,482 12,739 13,060 2020 21 12,421 12,702 13,079 2021 22 12,348 12,692 13,139 2022 23 12,324 12,704 13,208 2023 24 12,288 12,723 13,309 2024 25 12,270 12,757 13,401 2025 26 12,255 12,814 13,487 2026 27 12,238 12,866 13,575 Figure 1 Annual operational consumption actual and forecast for South Australia (all scenarios), 2007 08 to 2026 27 16,000 15,000 14,000 13,000 12,000 11,000 10,000 9,000 8,000 Historical Forecast Financial Year 2017 Weak 2017 Neutral 2017 Strong Actual 2016 Weak 2016 Neutral 2016 Strong AEMO 2017 7

As Figure 1 shows, the forecasts for the three scenarios have a similar spread between the scenarios as forecast in 2016, but are all generally higher, driven by a higher outlook for business consumption. Figure 2 shows the operational consumption forecasts for the Neutral scenario (black line), broken down by segment (coloured areas). The graph shows how underlying consumption is forecast to increase with population and economic growth. However, the coloured segments above the line represent how business and residential PV and energy efficiencies have reduced the forecast consumption and contribute significantly to the flat outlook for operational consumption for the state. Figure 2 Annual operational consumption forecast by segment for South Australia (Neutral scenario), 2007 08 to 2026 27 AEMO 2017 8

3. MAXIMUM DEMAND FORECASTS Key insights include: Maximum demand is expected to remain flatter, compared to last year s forecast declining trend. For summer 2016 17, South Australia s actual maximum operational demand (sent out) was 3,017 MW, which occurred on 8 February 2017. The observed actual is approximately midway between the 10% POE and 50% POE forecasts (see Table 4 below). Prices were very high, and a number of large loads did reduce consumption in the afternoon, by at least 50 MW in total at the time of maximum demand. If it had not been for this demand side participation, the actual observed demand would have been close to a 10% POE event. Just after observed maximum demand AEMO ordered load shedding of 100 MW to ensure system security. Demand had been increasing up to that point, but was levelling off. If load shedding had not been directed, the observed maximum demand could have been slightly higher. Over the next 10 years, on average the 10% POE summer maximum demand is forecast to decrease from 3,116 MW to 3,048 MW, under the Neutral economic and consumer outlook. Trends are similar to those for annual consumption, with rooftop PV and energy efficiency having a downward pressure on growth, keeping forecasts relatively flat. 3.1 Key differences between 2017 and 2016 NEFR forecasts The key difference is that the 10% POE maximum demand is forecast to remain relatively flat over the 10-year horizon under the Neutral economic and consumer outlook. In comparison, last year under the Neutral scenario a decrease was projected, at an annual average rate of 1.3% over the short term (2016 17 to 2019 20) and 1.8% over the medium term. The key reason for this difference is the changed outlook for business consumption. 3.2 Forecasts Maximum demand forecasts are summarised in Table 4 and Figures 3 and 4. Table 4 Summer operational maximum demand forecasts for South Australia, 2016 17 to 2026 27 (Neutral scenario, MW) Summer Actual 10% POE 50% POE 90% POE 2016 17 3,017 3,116 2,934 2,724 2017 18 3,050 2,848 2,676 2018 19 3,073 2,865 2,663 2019 20 3,110 2,911 2,715 2020 21 3,058 2,860 2,684 2021 22 3,035 2,872 2,699 2022 23 3,055 2,847 2,686 2023 24 3,017 2,820 2,649 2024 25 3,070 2,871 2,684 2025 26 3,082 2,897 2,699 2026 27 3,048 2,892 2,713 AEMO 2017 9

Figure 3 Summer operational maximum demand forecasts for South Australia, 2007 08 to 2026 27 (Neutral scenario) Figure 4 Summer 10% POE maximum demand forecast segments for South Australia, 2016 17 to 2026 27 (Neutral scenario) AEMO 2017 10

4. MINIMUM DEMAND FORECASTS AEMO has forecast minimum demand to investigate the impact of rooftop PV on the daily load profile. This provides useful information on network usage, which can inform further studies to evaluate operational implications. Key insights include: The summer minimum demand in 2016 17 was 800 MW on 6 November 2016. Minimum demand generally happens in summer. South Australia is the first NEM region in which high rooftop PV penetration caused minimum demand to shift from overnight to near midday. Since this first occurred in 2012 13, however, South Australia has experienced relatively warm summers. If South Australia was to experience the cold summers it did in 2002 or 2005, the mild temperatures coupled with installed PV capacity could produce quite low minimum demand (reflected in AEMO s minimum demand forecasts). AEMO forecasts negative minimum demand for the region under certain conditions, by 2027 28, just after the 10-year horizon of this report. For 90% POE minimum demand days, continued uptake of rooftop PV is forecast to offset 100% of demand in South Australia during the middle of the day. This may introduce operational challenges for balancing the power system. The power system and market will need to evolve to address these challenges, including utilising the opportunities from new technologies. For example, South Australia could store this excess generation, or could export it to the rest of the NEM via the interconnectors, provided they are in service. 4.1 Key differences between 2017 and 2016 NEFR forecasts The minimum demand forecast is generally consistent with the forecast produced last year. 4.2 Forecasts The 90% POE minimum demand, shown in Figure 5, is forecast to decline to 354 MW over the short term (2016 17 to 2019 20) under the Neutral scenario. Estimated rooftop PV generation at time of minimum demand is 731 MW by 2019 20 under this scenario. This is projected to be offset by 2.3 MW of battery charging at this time, for a combined impact of 729 MW. AEMO 2017 11

Figure 5 Summer 90% POE minimum demand forecast segments for South Australia, 2016 17 to 2026 27 (Neutral scenario) AEMO 2017 12