MDR. Device Classification Conformity Assessment Safety & Performance Requirements Technical Documentation

Similar documents
Medical Devices Regulation (MDR) Readiness Review

BSI Audits for MDR Certification

EU MDR Deep Dive: GSPRs, Technical Docs, PMS. 19 JUNE 2018 ASQ RAPS MASSMEDIC Waltham Woods

Classification of MDs under the European MDR. Joachim Makowski. Joachim Makowski, MED-RAS GmbH, a partner to confinis ag

The New EU Medical Device Regulation (MDR) An Active Device Lifecycle Approach Implementation and Remediation Activities

MDR ID: Definition: Applicable:

VIGILANZA E SORVEGLIANZA POST- COMMERCIALIZZAZIONE

QMS Aspects of the MDR (& IVDR)

Implications of the new MDR from a Product Testing and Certification Perspective

MedDev Rev 4 Medical Devices Regulation. Clinical Evidence Requirements Key Changes and Clarifications. Alan Eller 21 March 2017

Conformity Assessment of Medical Devices Under The New MDR

Technical documentation. Capita Selecta proposed MDR

IVDR Breakout. Copyright 2017 BSI. All rights reserved.

Changes in EU Clinical Data Requirements and Expectations

Factory CRO. Factory CRO for Medical Devices & IVDs

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

Regulatory Affairs in Medical Technology

Manufacturers. Factsheet for. of Medical Devices. Medical Devices Regulation (MDR) background. Act now to be ready on time!

General Safety and Performance Requirements Regulation (EU) 2017/ 745 on medical devices (MDR) - Annex I I. GENERAL REQUIREMENTS

Update: Proposed European Medical Device Regulations (MDR) April Monisha Phillips, PhD Global Head, Orthopaedic & Dental Devices

Bridging gaps: medical device directive vs regulation. Geert Corstens 1 November 2018

Medical Device Regulation Overview

Introduction to the new regulatory framework for medical devices and in vitro diagnostic medical devices

Ready or Not: The New Medical Device Regulations Are Here!

European Medical Device Regulations (MDR): What To Expect

Technical Documentation

Medicines (Database of Medical Devices) Regulations 2003

Changes to the Medical Devices Directive and affect on Manufacturers

Impact of the MD/IVD Regulations on Quality Management Systems

Technical documentation in the new MDR. Gabriele Catignoli, Andreas Purde

An introductory guide to the medical device regulation (MDR) and the in vitro diagnostic medical device regulation (IVDR)

Effects of the European MDR on the Quality Management System. Karl-Heinz Spohn

ASQ Tappan Zee Section Medical Devices, New Regulations and Standards. 26 th September / V. Fischer / Rev. 01

Essential Requirements Straumann Custom-made Dental Restorative Devices According to 93/42/EEC annex I as amended by 2007/47/EC

Self-Care Medical Devices Framework. Dr. Simone Breitkopf Head HEOR, Governmental and Public Affairs

MDR Post Market Surveillance

EU MDR: Tips for Effectively Addressing the New Requirements

Update on the IVDR. Sue Spencer

The upcoming EU MDR. Gert Bos. - key changes overview. Executive director & Partner. ..the practical approach

GUIDANCE NOTE FOR MANUFACTURERS OF CUSTOM-MADE MEDICAL DEVICES

Short intro to the MDR & IVDR (C)2018 QAdvis AB

EU MDR Timeline. Dr. Christian B. Fulda Jones Day FDLI Annual Conference Access materials at fdli.org/annual2018

COMMISSION RECOMMENDATION. of XXX. on the audits and assessments performed by notified bodies in the field of medical devices

The challenges of software medical device regulation.

Regulatory Framework for Medical Device

Post Market Surveillance (including PMCF): common non compliances

GUIDANCE NOTES FOR MANUFACTURERS OF CLASS I MEDICAL DEVICES

Medical Device Regulatory Framework 9 SEPTEMBER 2015 FUNDISA CONFERENCE JANE ROGERS

Standard and Directives on Medical Devices

Post market Surveillance ISO EU Medical Device Regulation

Guide for Class I Manufacturers on Compliance with European Communities (Medical Devices) Regulations, 1994

DRAFT MEDICAL DEVICE GUIDANCE DOCUMENT

Regulation of software a medical device

Update on Regulatory Environment- Europe Experience with 2007/47/EC M5 & Discussions on Possible Recast of EU Medical Device Regulations

Guidance on the Information Required for Notified Body Medical Device Personnel Involved in Conformity Assessment

New European Rules governing medical devices vigilance and combination products. Lincoln Tsang May 2008

Post Market Surveillance

Due diligence in the European medical devices industry

Guidance on legislation. Clinical investigations of medical devices guidance for investigators

MEDICAL DEVICE. Technical file.

Guidelines for conformity assessment of In Vitro Fertilisation (IVF) and Assisted Reproduction Technologies (ART) products

CABINET OF MINISTERS OF UKRAINE

Med-Info. Directive 98/79/EC on in-vitro diagnostic medical devices. TÜV SÜD Product Service GmbH

POSITION PAPER Moving from the MDD to the MDR

Notification of a Body in the framework of a technical harmonization directive

Unannounced Visits. Welcome! We will start the webinar presentation at 9am. Copyright 2014 BSI. All rights reserved.

GS1 Ireland Healthcare User Group (HUG) Information Day

Understanding Clinical Equivalence

Medical Device Regulation

Are Pharmaco- and Medical Device Vigilance the same?

UDI Database, Definitions/Descriptions and formats of the UDI core elements

Application of ISO/IEC 17011:2004 in the Field of Medical Device Quality Management Systems (ISO 13485)

EU MDR 10 Things Packaging Engineers Should Know

IVD Regulation Update

MEDICAL DEVICE GUIDANCE DOCUMENT REQUIREMENTS FOR LABELLING OF MEDICAL DEVICES

Changes to the Regulation of IVDs in Europe. Copyright 2012 BSI. All rights reserved.

MEDICAL DEVICE GUIDANCE DOCUMENT REQUIREMENTS FOR LABELLING OF MEDICAL DEVICES

MEDICINES CONTROL COUNCIL

HOW TO APPLY FOR MEDICAL DEVICE REGISTRATION UNDER MEDICAL DEVICE ACT 2012 (ACT 737)

New EU Medical Device Regulations.are you ready? Angela Stokes Senior Director Regulatory Affairs March 2017

Guidance for products without an intended medical purpose (Annex XVI) under the new Medical Device Regulation (EU 2017/745)

Impact of the IVD Regulations. Barbara Fallowfield Managing Director

CE Marking for Medical devices

GETTING READY FOR THE EUROPEAN UNION (EU) MEDICAL DEVICE REGULATION (MDR)

GENERAL AND ORGANISATIONAL REQUIREMENTS

Clinical Evaluation and Clinical Investigation update MDR

New Regulation (Draft) for Medical Devices. September 11, 2013 Dr. med. Christian Schübel

GUIDELINES ON MEDICAL DEVICES

Recast Medical Device directives Impacts on materiovigilance

Panel Discussion: European Medical Device Regulations Preparing for the Storm Moderator: Lenita Y. Sims Spears, Senior Quality Consultant/Senior

Notification of a Body in the framework of a technical harmonization directive

IVDR Workshop Diagnostik Akademie, Sven Hoffmann Global Head of Technical Competence Center IVD TÜV Rheinland LGA Products GmbH

A Review on European Union New Medical Device Regulations- 2017

The EU s In Vitro Diagnostics (IVD) Regulation:

PART 1 DEVICE MASTER FILE

SOFTWARE APPS AS MEDICAL DEVICES. The Regulatory Landscape 2015 WHITE PAPER WHITE PAPER PRODUCED BY MAETRICS

FINAL DOCUMENT. Global Harmonization Task Force

EU Update Proposed Regulations, Own Brand Labelling, Unannounced Audits

Clinical Data Evaluation Lessons Learned

MEDICAL DEVICE GUIDANCE

Transcription:

MDR Device Classification Conformity Assessment Safety & Performance Requirements Technical Documentation Suzanne Halliday, D.Phil. Jaishankar Kutty, Ph.D. Ronald Rakos, Ph.D BSI Roadshow, October 2017 1

Agenda Classification rules Annex VIII Conformity Assessment Annex IX to Annex XI General Safety and Performance Annex I Technical File Documentation Annex II PMS and PMS Technical Documentation Annex III 2

MDR Classification Annex VIII 3

MDR - Definitions Term MDR MDD Delta an invasive device which penetrates inside the body clarification that surgically through the surface of the body, including through An invasive device which penetrates inside the body invasive also includes Surgically Invasive mucous membranes of body orifices with the aid or in through the surface of the body, with the aid or in penetration through Device the context of a surgical operation; (Annex VIII) the context of a surgical operation. mucous membranes of body orifices Injured skin or mucous membrane Active device Reusable surgical instrument means an area of skin or a mucous membrane presenting a pathological change or change following disease or a wound. Covered under Article 2 active device means any device, the operation of which depends on a source of energy other than that generated by the human body for that purpose, or by gravity, and which acts by changing the density of or converting that energy. Devices intended to transmit energy, substances or other elements between an active device and the patient, without any significant change, shall not be deemed to be active devices. Software shall also be deemed to be an active device; Instrument intended for surgical use in cutting, drilling, sawing, scratching, scraping, clamping, retracting, clipping or similar procedures, without a connection to an active device and which is intended by the manufacturer to be reused after appropriate procedures such as cleaning, disinfection and sterilisation have been carried out. n/a Any medical device operation of which depends on a source of electrical energy or any source of power other than that directly generated by the human body or gravity and which acts by converting this energy. Medical devices intended to transmit energy, substances or other elements between an active medical device and the patient, without any significant change, are not considered to be active medical devices. Stand alone software is considered to be an active medical device. Instrument intended for surgical use by cutting, drilling, sawing, scratching, scraping, clamping, retracting, clipping or similar procedures, without connection to any active medical device and which can be reused after appropriate procedures have been carried out. introduced definition for injured skin or mucous membrane Device which acts by changing the density of energy are also considered active devices. This is considered a clarification only devices which can be reused vs intended by the manufacturer to be reused; mostly a clarification 4

MDR Definitions & Implementing Rules Term MDR MDD Delta Continuous use (a) the entire duration of use of the same device without regard to temporary interruption of use during a procedure or temporary removal for purposes such as cleaning or disinfection of the device. Whether the interruption of use or the removal is temporary shall be established in relation to the duration of the use prior to and after the period when the use is interrupted or the device removed; and (b) the accumulated use of a device that is intended by the manufacturer to be replaced immediately with another of the same type. means an uninterrupted actual use of the device for the intended purpose. However where usage of a device is discontinued in order for the device to be replaced immediately by the same or an identical device this shall be considered an extension of the continuous use of the device concept of continuous use extended to include devices that may be temporarily removed to be cleaned or disinfected and then re-used; However this is still considered a clarification since such use would be treated as 'continuous use' under the Directive as well Direct diagnosis A device is considered to allow direct diagnosis when it provides the diagnosis of the disease or condition in question by itself or when it provides decisive information for the diagnosis. n/a new definition Implantable device Covered under Article 2.5 implantable device means any device, including those that are partially or wholly absorbed, which is intended: to be totally introduced into the human body, or to replace an epithelial surface or the surface of the eye, by clinical intervention and which is intended to remain in place after the procedure. Any device intended to be partially introduced into the human body by clinical intervention and intended to remain in place after the procedure for at least 30 days shall also be deemed to be an implantable device; Any device which is intended: to be totally introduced into the human body or, to replace an epithelial surface or the surface of the eye, by surgical intervention which is intended to remain in place after the procedure. Any device intended to be partially introduced into the human body through surgical intervention and intended to remain in place after the procedure for at least 30 days is also considered an implantable device. Devices that are partially or wholly absorbed are considered implantable; 'Clinical' intervention vs 'surgical' intervention 5

Classification Rules MDR, Annex VIII MDR Rules 1 4: Non-invasive devices Rules 5 8 : Invasive devices Rules 9 13 : Active Devices Rules 14 22 : Special rules MDD Rules 1 4 : Non-invasive devices Rules 5 8 : Invasive devices Rules 9 12 : Active devices Rules 13 18 : Special rules 6

Rules 1-4: Non-invasive devices (in comparison with MDD) Rule 1 Rule 2 Rule 3 Rule 4 No change Addition of cells and tissues to the existing language Blood bags moved to MDR Rule 2 from Rule 18 of MDD Addition of human tissues and cells to blood, body liquids and other liquids Intended for implantation or administration vs Intended for infusion in MDD Inclusion of organ storage solutions, IVF media into the rule which are class III Addition of injured mucous membrane to injured skin Replacement of wounds with injuries to skin Also covers invasive devices that come into contact with injured mucous membrane 7

Rules 5 8: Invasive devices (in comparison with MDD/AIMD) Rule 5 Rule 6 Rule 7 Rule 8 No change clarifications only All devices intended specifically for direct contact with heart or central circulatory system now class III similar to devices in contact with central nervous system All devices intended specifically for direct contact with heart or central circulatory system now class III similar to devices in contact with central nervous system AIMD devices and accessories are class III Breast implants and surgical meshes are class III Total and partial joint replacements are class III Spinal disc replacement implants or implantable devices that come into contact with spinal column are class III with some exceptions (screws, wedges, plates and instruments) 8

Rules 9 13: Active Devices (in comparison with MDD/AIMD) Rule 9 Rule 10 Rule 11 Rule 12 Addition of active devices intended to emit ionizing radiation for therapeutic purposes, including devices which control or monitor such devices, or which directly influence their performance, are classified as class IIb. Addition of active devices that are intended for controlling, monitoring or directly influencing the performance of active implantable devices are classified as class III. Addition of monitoring to diagnosis; Active devices intended for diagnosis in clinical situations where the patient is in immediate danger as class IIb New rule on software Classifications range from class III class I Rule 11 in MDD No change Rule 13 Rule 12 in MDD No change 9

Rules 14 18: Special rules Rule 14 Rule 15 Rule 16 Rule 17 Rule 18 (Devices with medicinal substances) (Contraceptive devices, Devices for prevention of transmission of STDs) (Disinfectants, sterilizers) (Devices for recording x-ray diagnostic images) (Devices utilizing human or animal derivatives) Rule 13 in MDD Rule 14 in MDD Rule 15 in MDD Rule 16 in MDD Rule 17 in MDD Clarification that medicinal product can be derived from human blood or plasma Liable to act taken out No change Addition of sterilisers to disinfectants Disinfectants or sterilisers become IIb only if they are used for invasive devices and as the end point of processing No change language clarified Addition of cells (to tissues) Addition of human origin cells and tissues or derivatives The exception about contact with intact skin only, applies only to animal tissue and does not apply to human tissues or cells 10

Rules 19 22: Special rules Rule 19 Rule 20 Rule 21 Rule 22 (Devices incorporating or consisting of nanomaterials) (Body-orifice invasive devices intended to administer medicines by inhalation) (Devices consisting of substances and introduced into the body via body orifice or skin and that are absorbed by or locally dispersed) (Active therapeutic device with an integrated or incorporated diagnostic function) New rule New rule New rule New rule Classifications from III to IIa based on potential for internal exposure Classification IIa or IIb IIb if they impact the safety and performance of the medicine or intended to treat lifethreatening conditions Classification from IIa to III based on where they are used and whether they or their products of metabolism are absorbed Class III Only applies if such devices significantly determine the patient management Closed loop systems or automated external defibrillators 11

Conformity Assessment Procedures Annex IX, X, XI 12

Classification & Conformity Assessment MDD Competent Authority Assessment Class III Class IIb Notified Body Conformity Assessment Risk Self-Certification Class IIa Class Im /Is Class I Custom Made 13 13

Classification & Conformity Assessment MDR Commission Assessment Competent Authority Assessment Class III Class IIb Class III Implants Class IIb active administer medicine Class IIb Implants Notified Body Conformity Assessment Self-Certification Risk Class IIa Class Im /Is Class I Custom Made Class III Custom Made Implants Class Ir 14 14

Quality Management System Microbiology Technical Documentation Unannounced Audit Clinical Evaluation Consultation Procedure (CECP) (Article 54) 2001/83/EC EC/726/2004 2004/23/EC EU 722/2012 PSUR (Article 86) (*Annual) SSCP (Article 32) 15 Regulation EU 2017/745 Conformity Assessment Class III Implants 5 years * Class III 5 years * Class IIb Active intended to administer and/or remove medicines from the body sample per group 5 years * not submitted to NB Class IIb Implants 5 years * Sutures, staples, dental fillings, dental braces, tooth crowns, screws, wedges, plates, wires, pins clips connectors sample per group 5 years Class IIb sample per group Class IIa sample per category 5 years 5 years * not submitted to NB not submitted to NB 15

Quality Management System Microbiology Technical Documentation Unannounced Audit Clinical Evaluation Consultation Procedure (CECP) (Article 54) 2001/83/EC EC/726/2004 2004/23/EC EU 722/2012 PSUR (Article 86) (*Annual) SSCP (Article 32) 16 Regulation EU 2017/745 Conformity Assessment Class I Class Is, Im, Ir Class III Custom Made Implants 5 years * not submitted to NB Custom Made Procedure Packs (Article 22) 5 years Suppliers, Subcontractors *depends on certification held *depends on certification held 5 years EU Authorised Representatives, Importers, Distributors (Article 16) *impact sterile barrier, translate, repackage *impact sterile barrier, translate, repackage 5 years 16

General Safety & Performance Requirements Annex I 17

General Safety & Performance Requirements (Annex I) MDD 93/42/EEC: 13 Essential requirements AIMDD 90/385/EEC: 16 Essential requirements MDR 2017/745: 23 General Safety & Performance Requirements Similar to Essential Requirements in Directives. Similar content and topics Some numbering and organizational changes Expanded requirements (Labeling, Risk) New areas of emphasis (from standards and guidances, etc.) Some additional requirements because of merging of MDD with AIMDD Some topics move out of the SPR list into Articles/Annexes (Clinical, medicinal consultation) Some new topics introduced (devices without medical purpose, lay person use, etc.) 18 Copyright 2017 BSI. All rights reserved.

Annex I: Safety and Performance Requirements Chapter 1: General Requirements (SPRs 1-9) Chapter 2: Design and Manufacture (SPRs 10-22) Chapter 3: Information Supplied with the Device (SPR 23) 19 Copyright 2017 BSI. All rights reserved.

Annex I: Safety and Performance Requirements Chapter 1: General Requirements (SPRs 1-9) Chapter 2: Design and Manufacture (SPRs 10-22) Chapter 3: Information Supplied with the Device (SPR 23) Copyright 2017 BSI. All rights reserved. 1:Similar to ER 1 with additional emphasis on risk/benefit and state-of-the-art 2-5: Much greater emphasis on risk management 9: New requirement for devices without a medical purpose Remainder similar to Directive 20

Annex I: Safety and Performance Requirements 10: Much more detail regarding chemical, physical and biological properties, toxicology. and specific substances of concern. Chapter 1: General Requirements (SPRs 1-9) 11: More requirements for infection and microbial contamination 22: New requirement: Devices for lay person users Chapter 2: Design and Manufacture (SPRs 10-22) 20: Much more detail on mechanical and thermal risks Mitigate risks of fitting/refitting parts by design 16-18: Active and AIMD, many similar or identical, some new: Increased emphasis on cyber Chapter 3: Information Supplied security with the Device (SPR 23) More emphasis on ionising radiation/ electromagnetic interference Requirements from ISO 60601 12: Medicinal substances scope expanded to include substances that are absorbed by or locally dispersed in the human body Copyright 2017 BSI. All rights reserved. 13: Biological tissues expanded to include human tissues (nonviable) Also includes catch-all for non-viable biological substances of neither human nor animal origin 14: More requirements for interaction with the environment and compatibility with other devices, including ergonomics, calibration, disposal 21

Annex I: Safety and Performance Requirements Many clarifications on labelling requirements. 23.2: Additional requirements for UDI, devices incorporating human or animal tissues, medicines, absorbable devices, is it a MD & others 23.3: Specific requirements for labelling on sterile packaging Chapter 1: General Requirements (SPRs 1-9) Indication if carcinogenic/mutagenic/toxic (CMR) substances Chapter 2: Design and Manufacture (SPRs 10-22) 23.4: Many new IFU requirements and cross-referencing to articles, including (among others): Installation verification, PM, calibration, identification of consumable components and how to replace (23.4k) Many more specific warning requirements (EMC, medicinal substances, human or animal tissues, CMR and endocrine disruptors) (23.4s) Absorbable/dispersible materials (23.4t) Information on materials for implants (23.4u) Information security measures (23.4ab) Copyright 2017 BSI. All rights reserved. 23.1: More general requirements (e.g. format, readability, understood, availability, eifu, lay person etc.), residual risks Chapter 3: Information Supplied with the Device (SPR 23) Labeling requirements have changed and expanded significantly 22

Technical Documentation Annex II BSI Confidential, Copyright 2017 BSI. All rights reserved 23

Annex II Technical Documentation The technical documentation and, if applicable, the summary thereof to be drawn up by the manufacturer shall be presented in a clear, organised, readily searchable and unambiguous manner.. Key Change: The MDR is very prescriptive regarding the Technical Documentation content and formatting. BSI Confidential, Copyright 2017 BSI. All rights reserved 24

Annex II Technical Documentation Technical Documentation requirements are subdivided into the following 6 sections: 1. Device description and specification, including variants and accessories 2. Information to be supplied by the manufacturer 3. Design and manufacturing information 4. General safety and performance requirements 5. Benefit-risk analysis and risk management 6. Product verification and validation BSI Confidential, Copyright 2017 BSI. All rights reserved 25

Annex II 1. Device description and specification, including variants and accessories Product name, description, intended purpose, intended users Basic UDI-DI or other unambiguous reference (product code, catalogue number etc.) Intended population, indications, contraindications, warnings Principle of operation of the device and mode of action; scientifically demonstrated Rationale for considering the product a medical device Device classification, applicable rules & rationale Explanation of any novel features Description of accessories provided with or without the device Description of all the relevant variants of the device sizes, shapes, material thicknesses, etc. Device pictures, relevant drawings Description of all the relevant raw materials along with a risk assessment from biological safety perspective Technical specifications, dimensions & performance attributes Reference & overview of previous and similar generations of the subject device and device market history Discussion of medicinal therapies used in conjunction with procedure BSI Confidential, Copyright 2017 BSI. All rights reserved 26

Annex II 2. Information to be supplied by the manufacturer (SPR 23) A complete set of: the label or labels on the device and on its packaging and the instructions for use in the languages accepted in the Member States where the device is to be sold Promotional materials (Article 20) Implant Card (Article 18, SPR 23.4 aa) Summary of safety and clinical performance (SSCP, Article 32) Annex II 3. Design and manufacturing information Information to allow the design stages applied to the device to be understood Complete information and specifications, including the manufacturing processes and their validation, their adjuvants, the continuous monitoring and the final product testing. Data shall be fully included in the technical documentation Note: ISO 13485:2016 requires design validation to be conducted on representative product (e.g., sterile finished devices). Identification of all sites including suppliers and subcontractors; where design and manufacturing activities are performed BSI Confidential, Copyright 2017 BSI. All rights reserved 27

Annex II 4. General safety and performance requirements Documentation shall contain information to demonstrate conformity to general safety and performance requirements (GSPR or SPRs) that are applicable (Annex I) taking into account its intended purpose and shall include methods used to demonstrate conformity (justification, validation and verification). Demonstration SPR of Applicability conformation shall include: Standard or CS Demonstration/ testing GSPRs that apply explanation of why any GSPR does not apply; (justification, Method(s) used to demonstrate conformity validation and verification) Harmonised standards, CS or other solutions applied and X Location (Precise identity) The precise identity of the controlled documents offering evidence of conformity Harmonised Y Standard, CS or method(s) [including] a cross-reference to the location of such evidence within Z the full technical documentation Have to clearly show/demonstrate how each SPR is met/satisfied. BSI Confidential, Copyright 2017 BSI. All rights reserved 28

Annex II 5. Benefit-risk analysis and risk management The documentation shall contain information on: The benefit-risk analysis (Annex I, Section 1 and 8) The solutions adopted and the results of the risk management referred to in Section 3 of Annex I (SPR 3) SPR 3 is essentially a summary of the requirements of EN ISO 14971:2012 BSI Confidential, Copyright 2017 BSI. All rights reserved 29

Annex II 6. Product verification and validation The documentation shall contain the results and critical analyses of all verifications and validation tests and/or studies undertaken to demonstrate conformity with the requirements of the MDR and in particular the applicable SPRs Pre-Clinical and Clinical data In Vitro & In Vivo test outcomes, simulated use testing, evaluation of the published literature and overall discussion of preclinical safety in combination with conformance with specifications Detailed discussion of test design, test protocols and reports with data analysis and conclusions in particular for the following: biocompatibility (Annex I, SPR 10) physical, chemical and microbiological characterization (Annex I, SPR 10 and 11) electrical safety and electromagnetic compatibility (Annex I, SPR 18, AIMD: SPR 19) software verification and validation (Annex I, SPR 17) stability, including shelf life (Annex I, SPR 7) performance and safety (Annex I, SPR 1 and 6) Where applicable conformity to Directive 2004/10/EC (GLP Directive) must be demonstrated (for devices containing medicinal substances) Where no new testing has been conducted the documentation shall incorporate a rationale for that decision Very prescriptive requirements with links to SPRs and CER; evaluation of the published literature with respect to pre-clinical testing Clinical evaluation plan and report (along with updates) per Article 61(12) [CER] and Part A of Annex XIV (detailed description of CER) BSI Confidential, Copyright 2017 BSI. All rights reserved 30

Annex II 6. Product verification and validation Additional information for specific cases: Medicinal substances requirements per Directive 2001/83/EC (Annex I, SPR 12) Requirements for devices utilizing tissues or cells of human or animal origin or their derivatives (Annex I, SPR 13) Devices composed of substances or combinations thereof intended to be introduced into the human body that are absorbed by or locally dispersed (Annex I, SPR 12) Carcinogenic, mutagenic or toxic to reproduction (CMR) and endocrine-disrupting substances (Annex I, SPR 10.4) Sterility and microbiological condition (Annex I, SPR 11) Measuring Function (Annex I, SPR 15) Devices connected to other devices, description and compliance with SPR (Annex I, SPR 14) BSI Confidential, Copyright 2017 BSI. All rights reserved 31

Technical Documentation on Post-Market Surveillance Annex III and overview of MDR PMS requirements BSI Confidential, Copyright 2017 BSI. All rights reserved 32

Article 2, Definition 61 Post-Market Surveillance all activities carried out by the manufacturer in cooperation with other economic operators to institute and keep up to date a systematic procedure to proactively collect and review experience gained from their devices placed on the market, made available on the market or put into service for the purpose of identifying any need to immediately apply any necessary corrective or preventive actions; QMS PMS Vigilance Reactive PMS Proactive PMS PMCF Current MDD Requirements BSI Confidential, Copyright 2017 BSI. All rights reserved 33

Post Market Surveillance (PMS) Specific Requirements in the MDR 1. PMS system of the manufacturer (Article 83) 2. PMS plan (Article 84) 3. PMS report (Article 85) 4. Post Market clinical follow-up (PMCF) report (Article 61, 11 and Annex XIV, Part B) For Class III devices and implantables devices the PMCF evaluation report and if indicated the Summary of Safety and Clinical Performance (SSCP, Article 32) shall be updated at least annually 5. Periodic safety update report (PSUR, Article 86) 6. Summary of Safety and Clinical Performance (SSCP, Article 32) BSI Confidential, Copyright 2017 BSI. All rights reserved 34

Chapter VII: PMS, vigilance and market surveillance Article 83 PMS system of the manufacturer For each device, manufacturers shall plan, establish, document, implement, maintain and update a PMS system in a manner that is proportionate to the risk class and appropriate for the type of device. The PMS plan shall be an integral part of the manufacturer s QMS referred to in Article 10(9). The PMS system shall be suited to actively and systematically gathering, recording and analysing relevant data on the quality, performance and safety of a device throughout its entire lifetime, and to drawing the necessary conclusions and to determining, implementing and monitoring any preventive and corrective actions. 35

PMS system of the manufacturer shall be used for (Article 83): Device Lifetime QMS PMS 36

PMS Article 83, 87 If, in the course of the post-market surveillance, a need for preventive or corrective action or both is identified, the manufacturer shall implement the appropriate measures and inform the competent authorities concerned and, where applicable, the notified body. serious incident means any incident that directly or indirectly led, might have led or might lead to any of the following: a) the death of a patient, user or other person, b) the temporary or permanent serious impairment of the patient's, user's or other person's state of health, c) a serious public health threat; field safety corrective action means corrective action taken by a manufacturer for technical or medical reasons to prevent or reduce the risk of a serious incident in relation to a device made available on the market; Where a serious incident is identified or a field safety corrective action is implemented, it shall be reported in accordance with Article 87. 37

PMS Article 84, 85, 86 Article 84 PMS plan Article 85 PMS Report Article 86 - PSUR The post-market surveillance system Manufacturers of Class I devices referred to in Article 83 shall be Summary of results and conclusions based on a post-market surveillance from analysis of PMS data gathered plan, the requirements for which are as according to PMS plan set out in Section 1.1 of Annex III. Include description and rationale for For devices other than custom-made any preventive and corrective action devices, the post-market surveillance taken plan shall be part of the technical documentation specified in Annex II. Updated when necessary Made available to NB and CA on request Manufacturers of class IIa, IIb and III devices shall prepare a PSUR for each device and for each category/group of devices summarizing the PMS data per the PMS plan (Article 83). Throughout the lifetime of the device, the PSUR shall include: Conclusions of benefit-risk determination; Main findings of PMCF Sales volume, estimate of size and characteristics of population and frequency of usage 38

Annex III Technical Documentation on PMS The technical documentation on post-market surveillance to be drawn up by the manufacturer in accordance with Articles 83 to 86 shall be presented in a clear, organised, readily searchable and unambiguous manner and shall include in particular the elements described in this Annex. 1.1 a: The post-market surveillance plan shall address the collection and utilization of available information, in particular: information concerning serious incidents, including information from PSURs, and field safety corrective actions records referring to non-serious incidents and data on any undesirable side effects information from trend reporting (Article 88) relevant specialist or technical literature, databases and/or registers information, including feedbacks and complaints, provided by users, distributors and importers publicly available information about similar medical devices 39

Annex III 1.1 b: PMS plan Shall cover at least: proactive and systematic process to collect the information referred to in previous slide (EN ISO 13485:2016, 8.2.1) Comparison between device and similar products on the market effective methods to assess the collected data (including complaints, market-related experience, trend reporting, recognise significant data) suitable indicators and threshold values that shall be used in the continuous reassessment of the benefit-risk analysis and risk management (Annex I, SPR 3) complaint investigation and analysis (EN ISO 13485:2016, 8.2.2) methods/protocols to manage events subject to the trend reporting regarding any statistically significate increase in the frequency or severity of incidents (Article 88) BSI Confidential, Copyright 2017 BSI. All rights reserved 40

Annex III 1.1 b: PMS plan Shall cover at least: methods to communicate effectively with NB, CA, economic operators and users (EN ISO 13485:2016, 8.2.3) reference to procedures to fulfil the manufacturers obligations (PMS) procedures to identify and initiate appropriate corrective measures/corrective actions effective tools to trace and identify affected devices PMCF plan (Annex XIV, Part B) or justification as to why one is not applicable 1.2 The PSUR referred to in Article 86 and the post-market surveillance report referred to in Article 85. BSI Confidential, Copyright 2017 BSI. All rights reserved 41

PMS in the MDR QMS PMS Article 83 Vigilance Article 87-90 Reactive PMS Proactive PMS MDR Requirements PSUR Article 86 PMCF Annex XIV BSI Confidential, Copyright 2017 BSI. All rights reserved SSCP Article 32 42

Conclusion Classification rules Annex VIII Added clarifications & new rules Conformity Assessment Annex IX to Annex XI CECP - Class III implantable, certain Class IIb General Safety and Performance Annex I Increased from 13 to 23 Technical File Documentation Annex II Prescriptive requirements PMS and PMS Technical Documentation Annex III More specifics around PMS requirements 43

Where can I find full details of the changes? bsigroup.com/mdr-revision bsigroup.com/ivdr-revision Webinars: bsigroup.com/webinars Whitepapers: bsigroup.com/whitepapers Please ask if you want any extra information from BSI. Copyright 2017 BSI. All rights reserved. 44