Data Center Catalog. Flexibility, Strength, and Energy Savings

Similar documents
Data Center The New Standard in Data Center Design... ASM H-D System

EQU P SECURE. Protect Your Servers And Data By Using ASM. Find out how. Equipment Securing Made Easy. Don t Waste Your Time & Money

FS300 (1,500 lb) Specifications For HPL Covered Panels On Bolted Stringer System

NUM THAVEER RUNG. Benefits: Huatong anti-static or conductive raised access floor panels are widely used in computer rooms and clean rooms.

DATA CENTER ACCESS FLOOR SYSTEM

Tate Access Floors, Inc. All Steel 1000 Access Floor Panel 600 mm Bolted Stringer Understructure System

Tate Access Floors, Inc. ConCore 1250 Access Floor Panel Bolted Stringer Understructure System

WC SERIES SPECIFICATION SECTION ACCESS FLOORING

TecBase Access Flooring

S125 Specifications For HPL Covered Panels On Bolted Stringer System

You Can Help the Environment with Green Building Technology

Solidfeel Access Flooring v1.0 (1 October 2012) 1

Pentafloor Access Flooring v1.0 (1 October 2012) 1

Pentafloor Access Flooring v1.0 (1 October 2012) 1

ARCHITECTURAL SPECIFICATIONS

You Can Help the Environment with Green Building Technology

PROPERTY OF UNIFLOOR INDIA

Tate Access Floors, Inc. ConCore 1000 Access Floor Panel 600 mm Low FFH PosiLock Understructure Cornerlock System

Tate Access Floors, Inc. ConCore 1000 Access Floor Panel PosiLock Understructure

Tate Access Floors, Inc. ConCore 1500 Access Floor Panel PosiLock Understructure

Don t gamble with your casino s ability to adapt. Implement a solution. Setting the standard in Access Flooring with Casino. Systems designed to Win

System Overview. Steel Cementitious Panel HPL/ Vinyl System

RAISED FLOOR SYSTEM IB FLOOR

Tate Access Floors, Inc. WC5000 Air Seal Access Floor Panel Cornerlock Understructure

System Overview. Steel Cementitious Panel Ultrafix System

SPECIFICATION FOR PERMANENT BEAM GRANDSTAND WITH INTERLOCK WELDED DECK SYSTEM

FS SERIES. Access Flooring Made Affordable.

CS SERIES. Access Flooring Made Affordable.

SECTION ORCHESTRA PIT FILLER

SEOKYUNG TSC ALUMINUM RAISED ACCESS FLOORS

Tate Access Floors, Inc. ConCore Access Floor Panel on Bolted Stringer Understructure System

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

K. ASTM F436- Standard Specification for Hardened Steel Washers; 2011.

SHERIDAN SEATING INC.

Materials Carbon Steel and Malleable Iron are used in the manufacture of concrete inserts. Stainless Steel and other materials are available.

Iso Floor The dynamic raised floor offering full flexibility and stability in Data Centers and Telecom Network Operation Centers.

SECTION METAL STAIRS

Smarter. Safer. Leaner.

SECTION ENTRANCE FLOOR GRILLES STAINLESS STEEL GRATING

MASTERSPEC - SHORT FORM. B. See Division 5 Section "Metal Stairs" for steel tube railings associated with metal stairs.

SECTION ( ) RAISED ACCESS FLOORING

SECTION WALL AND DOOR PROTECTION

H D P SOLID PHENOLIC FLOOR BRACED COMPARTMENTS SECTION FB TOILET PARTITIONS

SECTION TOILET PARTITIONS. A. Section Structural Steel: Supports for ceiling hung compartments.

UNIFLOOR. Raised Access Flooring Solutions

Index. 1 - Index. 2 - Introduction & Pentafloor Solution. 3 - Understucture Systems. 4 - Why use Pentafloor. 5 - Cement Filled Access Floor Panels

SECTION MEDICATION CABINET. 1.1 SUMMARY A. Section Includes: 1. Medication cabinets with self-contained refrigerator and fixtures.

SHERIDAN SEATING INC.

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

GENERAL SPECIFICATION FOR GI DECKING SYSTEM

SECTION ALTERNATING TREAD STEEL STAIRS

Trex Commercial Products page Metal Railing

1 1 4" FRAMING SYSTEM

ALARIS CONSOLE ABOUT ALARIS CONSOLE ALARIS CONSOLE FEATURES. Product Specification Document Date Published: September 17, 2004

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

SECTION HANDRAILS AND RAILINGS. Display hidden notes to specifier. (Don't know how? Click Here)

UNDERFLOOR AIR DISTRIBUTION SYSTEM

Union County Vocational - Technical Schools Scotch Plains, New Jersey

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

HAWORTH TECCRETE WITH PORCELAIN FLOOR COVERING - CSI Specifications 04/25/2017

Concrete Inserts. B Adjustable Metal Deck Ceiling Bolt


PASSAIC COUNTY TECHNICAL INSTITUTE CCA 1422 NEW S.T.E.M. BUILDING 2017

1.02 SYSTEM DESCRIPTION

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

SECTION SECURITY GRILLES 679 SERIES SUPERGARD SIDE FOLDING GRILLE

1.02 SYSTEM DESCRIPTION

CamassCrete. Low Profile Cable Management Access Floor System. User Friendly % reusable LEED compliance Fully accessible Cable Trenches

SEISMIC PROTECTION SYSTEMS Bracing Products for Racks & Cabinets

B. LEED Submittals (Projects authorized for LEED certification only)

SECTION ORNAMENTAL ALUMINUM FENCING

SECTION 2 DIVISION 05 METALS

7. New railings for existing buildings shall be designed to match any existing railings unless there is a compelling reason for change.

HDPE SOLID POLYMER-PLASTIC FLOOR BRACED COMPARTMENTS SECTION FB WEIS/POLY TOILET PARTITIONS

CamassCrete CR1000W. Users Friendly

DB10 BLTD C10 Pipe Support. Description. Manufacturer Information BOLTED FRAMING GTIN UPC

SECTION ORNAMENTAL WELDED STEEL FENCING

American Metal Specialties, Inc.

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

SPECIFICATION FOR CI DECKING SYSTEM

SECTION ALUMINUM HANDRAIL SYSTEMS

SECTION METAL ATHLETIC LOCKERS

# DAYTONA BEACH PIER BUILDING RESTORATION 06/10

RAISED ACCESS FLOOR SYSTEM TECHNICAL SPECIFICATION

B. Shop Drawings: Include plans, elevations, sections, details, and attachments.

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Preassembled steel stairs with concrete-filled treads.

SECTION METAL STAIRS

Work Order Number *************************************************************************** SECTION C20 STAIRS 02/18

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

SECTION DECORATIVE METAL RAILINGS

Commercial & Data Centre Product Solutions Guide

PRESTON HEALTH SERVICES ARCHITECT'S NO. 2700

Banyan Air Service November 18, 2011 AVE Aviation and Commerce Center Building 1 Miami, FL

System Overview. Calcium Sulphate Interlock System

Solutions Railing Overview ACTUAL FREIGHT CHARGES APPLY TO ALL SOLUTIONS RAIL ORDERS

SECTION PREFABRICATED SHOWER COMPARTMENTS

Transcription:

Data Center Catalog Flexibility, Strength, and Energy Savings Raise your level of business with our patented, award winning, and industry leading raised access flooring systems. Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION

ASM AirFlow AirFlow Perforated Panels, Standard and Directional Grates A complete array of cooling solutions for all applications and loading requirements. Data Center Equipment Room Technical Spaces Keeping your servers cool 2 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

AF250 AF320 AF500/AF600 DAG500 AF-Series Performance Guide AF250 AF320 AF500 AF600 DAG500 (Directional) Concentrated Load Rating 1,000 lbf (4.45 kn) 1,500 lbf (6.67 kn) 1,750 lbf (7.79 kn) 2,500 lbf (11.12 kn) 2,000 lbf (8.90 kn) Uniform Load Rating 400 psf (1,952 kg/m 2 ) 800 psf (3,904 kg/m 2 ) 500 psf (2,440 kg/m 2 ) 700 psf (3,416 kg/m 2 ) 500 psf (2,440 kg/m 2 ) Ulitmate Load Rating 3,200 lbf (14.23 kn) 4,500 lbf (20.00 kn) 3,500 lbf (15.57 kn) 5,000 lbf (22.24kN) 4,200 lbf (18.68 kn) Impact Load Rating 175 lb (79 kg) 300 lb (136 kg) 175 lb (79 kg) 200 lb (91 kg) 175 lb (79 kg) ROLLING Rolling LOAD Load Rating: RATING: 10-Pass Test 400 lbf (1.78 kn) 1,500 lbf (6.67 kn) 2,000 lbf (8.90 kn) 2,500 lbf (11.12 kn) 1,500 lbf (6.67 kn) 10K-Pass Test 400 lbf (1.78 kn) 1,250 lbf (5.56kN) 2,000 lbf (8.90 kn) 2,500 lbf (11.12 kn) 1,250 lbf (5.56 kn) At 0.10 Static Pressure without Damper 610 CFM 2060 CFM 3060 CFM 3060 CFM 3220 CFM Open Area 25% 32% 56% 56% 62% Panels are tested per CISCA Recommended Test Procedures for Access Floors on actual support understructure. A minimum safety factor of 2 is recommended by international standards and building codes. Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 3

ASM AirFlow Product List AF250 Steel Air Flow Perforated Panel ASM s AF250 perforated panel has a free open area of 25% and is available with optional mechanical damper. 25% Open area for high volume air flow 24 or 600 mm size Available with top-adjusting slide dampers Completely interchangeable with FS-Series and S-Series panel systems High pressure laminate finish PARTIAL TOP VIEW PARTIAL SIDE VIEW AF500 and AF600 Aluminum Air Grate For cold aisles, the Accel-Air is a strong and durable panel with a free open area of 56% for those applications requiring the highest cooling conditions. Accel-Air panels come standard with powder coat ESD epoxy finish. 56% Open area for high volume air flow 24 or 600 mm size Available with top-adjusting slide dampers or opposed blade dampers Completely interchangeable with FS-Series and S-Series panel systems Die cast aluminum construction Suitable for clean room applications Made of 100% recycled material ESD Conductive epoxy paint finish PARTIAL TOP VIEW PARTIAL SIDE VIEW 4 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

AF320 Steel Air Flow Perforated Panel With 32% open area, the AF320 offers an intermediate amount of air delivery, while maintaining high strength. The AF320 offers additional flexibility when balancing and cooling in the data center. 32% Open area for high volume air flow Completely interchangeable with FS-Series and S-Series panel systems Green rated, uses 82% recycled material Rated at 1,500 lb concentrated load and 4,500 lb ultimate load Welded steel assembly with standard ESD powder coated finish PARTIAL TOP VIEW PARTIAL BOTTOM VIEW DAG500 Directional Aluminum Air Grate The high strength directional air grate has a load rating of 2,000 lbf to ensure top performance in the ever increasing loads of today s data center. The angled rib design directs air flow towards the front of the equipment allowing for more efficient air delivery and cooling. 61.3% Open area Available in 24 size ESD finish powder coat epoxy paint Corner-Lock feature available 100% Variable damper setting Adjustable from top of panel Die cast aluminum construction Available with adjustable dampers PARTIAL TOP VIEW SECTION VIEW PARTIAL SIDE VIEW Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 5

ASM Filled Steel Panel Series FS-Series Filled Steel Panels The most specified product for data center applications, with 6 different load ratings. ASM s Enviro Panel: Up to 3,000 lbf design load / 10,000 lbf Ultimate load FS-Series Performance Guide PANEL CONCENTRATED SAFETY ULTIMATE UNIFORM IMPACT ROLLING LOADS DESIGN LOADS FACTOR LOADS LOADS LOADS 10 PASS 10K PASS (lbf) (kn) MIN.2x (lbf) (kn) (psf) kg/m 2 (lb) (kg) (lb) (kg) (lb) (kg) FS100 1000 4.45 PASS 3300 14.68 500 2240 175 79 900 408 700 310 FS200 1250 5.56 PASS 3900 17.35 600 2928 175 79 1150 522 900 408 FS300 1500 6.67 PASS 5400 24.02 700 3416 175 79 1300 590 1100 499 FS400 2000 8.90 PASS 6300 28.02 800 3904 200 91 1600 726 1300 590 FS500 2500 11.12 PASS 7000 31.14 900 4393 200 91 2200 998 2000 907 FS600 3000 13.34 PASS 10000 44.48 1000 4881 400 181 3000 1361 3000 1361 ASM is proud to lead the industry with our steel panel design, by developing the first 3,000 lbf. rated cementitious filled welded steel panel. We have engineered the FS600 to support a 3,000 lbf. design load with rolling loads in excess of 3,000 lbf. when tested per CISCA. 6 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

FS-Series Technical Information Physical Data Fire Rating of Bare Panel: Class A Flame Spread (Per ASTM E84) Non-Combustible Materials (Per ASTM E136) Electrical Resistance ASTM/NFPA 99A Finish Options HPL Tile (1/16 or 1/8 ) ASM Smart-Trim, Dura-Trim or monolithic HPL Corner-Lock Vinyl Tile: VPT Con-Tile (static conductive) VPT Stat-Tile (static dissipative) Rubber Tile: Antistatic Standard Custom finishes Contact ASM for tile color options Understructure Options Rigid Grid Bolted Stringers: 2 x 2 System 2 x 4 System 4 x 4 Basketweave system Corner-Lock Hot dip galvanized and nickel chrome Seismic pedestals and bracing Features Available in 24 or 600 mm size Powder coat epoxy paint finish Welded steel construction Full-Strength deep drawn corners Light weight cementitious fill Recycled materials Patented PGD Grounding Clip on Tiled Panels Varies with tile TILE COVERED PANEL TILED CORNER-LOCK PANEL PARTIAL BOTTOM VIEW Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 7

ASM Equip Secure EQU P SECURE Seismic Systems Don t Waste Your Time & Money on Complicated Bracing Schemes 3 Easy Steps 1. Determine seismic pedestal system to install under equipment 2. Install ASM EQUIPsecure system under equipment 3. Bolt equipment to access floor panels SAF8000 PANELS ARE CORNER-BOLTED TO PEDESTAL TO PREVENT UPLIFT LARGE FLAT WASHER ON BOTTOM OF PANEL RIGID-GRID STRINGER SYSTEM HEAVY-DUTY SEISMIC PEDESTAL WITH THREADED ROD SCREWED INTO TOP OF BASE TUBE TO PREVENT UPLIFT METHOD OF ATTACHING EQUIPMENT TO RAISED ACCESS FLOOR PANELS 8 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

SAF8000 Equipment Mounting Panel PHYSICAL DATA 24 or 600 mm size Weight of bare panel: 72 lb. Fire rating of bare panel: Class A flame spread Non-Combustible materials PERFORMANCE DATA Concentrated load rating: 8,500 lbf (37.8 kn) Uniform load rating: 2,500 psf (12,201 kg/m 2 ) Ultimate load rating: 20,000 lbf (89 kn) Safety factor: 2.5 Impact load rating: 1,000 lb. (454 kg) Rolling load rating: CISCA Wheel C (10 Pass): 8,000 lbf (35.7 kn) FINISH OPTIONS HPL tile (1/16 or 1/8 ): ASM Smart-Trim, Dura-Trim, or Mono Vinyl tile: VPT Con-Tile (Static Conductive) VPT Stat-Tile (Static Dissipative) Rubber tile: Antistatic Standard Epoxy paint or mill finish UNDERSTRUCTURE OPTIONS Corner-Bolted Rigid grid bolted stringers 2 x 2 System 2 x 4 System 4 x 4 Basketweave system Pedestals are sized to suit application t 1/2" Machined to Match Adjacent Panel _L T 1.25" t Counterbore for 1 /2" Socket Head Cap Screw Countersink for 1 / 4" Flat Head Screw SAF800 BOTTOM VIEW SAF800 BARE CORNER-LOCK PANEL WITH SOCKET HEAD CAP SCREW AL8000 BARE CORNER-LOCK PANEL WITH STANDARD 1/4-20 FASTENER Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 9

ASM Understructure Understructure ASM offers the most comprehensive variety of support types, providing economical solutions for non-seismic to high risk seismic regions. This full line of pedestals can further be strengthened by bolting them to the concrete slab or in combination with ASM s seismic bracing for the most solid and seismic resisting access flooring systems available. FS / S 4x4 Rigid Grid System ASM FS-Series or S-Series Panel 1/4-20 Fastener SS-4 Stringer (HDG) H100 Head (NCH) 7/8" Sq. x 16 Ga. Steel Tube (HDG) 4" Sq. x 1/8" Thick Steel Base Plate (HDG) Typical Understructure Configuration NOTE: DATA SHEET DRAWING AND INFORMATION ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. B4201 / H100 Pedestal (REV 8/07) ASM Modular Systems Inc Ṛ 9500 Industrial Center Dr. Ladson, SC 29456 TEL: 843-534-1110 FAX: 843-534-1111 www.asmproducts.com CS - 1545 Every ASM stringer boasts solid tube construction to resist bowing and spreading during heavy loads. A factory applied solid vinyl gasket creates a quiet fit between the stringer and panel. 10 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

ASM Understructure Product List B4201/H100 B42M10/H100 B5210/H100 B54M01/H100 H100 Head (NCH) Adjusting Nut 7/8 Sq. x 16 Ga. Steel Tube (HDG) 4 Sq. x 1/8 Thick Steel Base Plate (HDG) H100 Head (NCH) Adjusting Nut B42m10 Base Assembly 1 Dia. x 16 ga. Wall Structural Steel Tube Swaged for 3 Length to Accept a 3/4 Dia. Rod and Welded to Base Plate (HDG) 4 Sq. x 2.0 mm Thick Steel Base Plate (HDG) H100 Head (NCH) Adjusting Nut B5210 Base Assembly 1 Dia. x 16 ga. Wall Structural Steel Tube Swaged for 3 Length to Accept a 3/4 Dia. Rod and Fillet Welded to Base Plate (HDG) 5 Sq. x 1/8 Thick Steel Base Plate with (4) 7/16 Dia. Anchor Holes @ 3-5/8 C-to-C Distance (HDG) H100 Head (NCH) Adjusting Nut 7/8 Sq. x 16 Ga. Steel Tube (HDG) 5 Sq. x 4.0mm Thick Steel Base Plate (HDG) B5318A/H100 B6318A/H100 B6613A/H100 B8825C/H225 H100 Head (NCH) Adjusting Nut B5318 Base Assembly 1-3/4 Dia. x 16 ga. Wall Structural Steel Tube Swaged for 4 Length to Accept a 3/4 Dia. Rod and Fillet Welded to Base Plate (HDG) 5 Sq. x 5mm Thick Steel Base Plate with (4) 7/16 Dia. Holes @ 3-5/8 C-to-C Distance (HDG) H100 Head (NCH) Adjusting Nut B6318A Base Assembly 1-3/4 Dia. x 16 ga. Wall Structural Steel Tube Swaged for 4 Length to Accept a 3/4 Dia. Rod and Fillet Welded to Base Plate (HDG) 6 Sq. x 5mm Thick Steel Base Plate with (4) 9/16 Dia. Holes @ 4-1/4 C-to-C Distance (HDG) H100 Head Assembly 3-1/4 Sq. x 4mm Thick Head Plate with (8) 1/4-20 Tapped Holes Fillet Welded to 3/4 Dia. x 4 Long Solid Steel Threaded Rod (NCH) 3/4-10 Jam Nut 1 Thick Solid Steel Insert With 3/4-10 Threaded Hole Welded to Base Tube (HDG) 1.660 O.D. x 1.380 I.D. Structural Steel Pipe Fillet Welded To Base Plate (HDG) 6 Sq. x 3/8 Thick Steel Base Plate with (4) 9/16 Dia. Holes @ 4-1/4 C-to-C Distance (HDG) 1/4-20 Tapped Hole For Ground Connection H225 Head Assembly 3 Sq. x 1/4 Thick Head Plate with (8) 1/4-20 Tapped Holes Fillet Welded to 1-8 x 4 Long Solid Steel Threaded Rod (NCH) 1 Thick Solid Steel Insert With 1-8 Threaded Hole Welded to Base Tube (HDG) 2.875 O.D. x 2.323 I.D. (2-1/2 Sched. 80 Pipe Size) Structural Steel Tube Fillet Welded To Base Plate (HDG) B8825C Base Assembly 8 Sq. x 1/2 Thick Steel Base Plate with (4) 3/4 Dia. Holes @ 5 C-to-C Distance (HDG) 1/4-20 Tapped Hole For Ground Connection * NCH - Nickel Chrome * HDG - Hot Dipped Galvanized Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 11

ASM Understructure Product List Stringers 46.9 [1191] 1.95 [50] SIDE SECTION VIEW Sound Deadening Gasket 0.86 [22] Countersink for Flat Head Screw 1.26 [32] 0.43 [10.9] TOP END VIEW END SECTION VIEW Patented PGD Electrical Grounding Clips MECHANICAL FASTENER THIS CONNECTION ALLOWS CURRENT TO FLOW FROM PANEL TO UNDERSTRUCTURE Is your floor grounded? If there is electrical build-up or a grounding problem on top of the floor, it can cause major problems and shut down your system..125 BRASS GROUNDING CLIP ASM is the only manufacturer to comprehensively address grounding problems by incorporating a solid brass patented Positive Grounding Device (PGD) on every tile covered panel in a rigid grid system as standard equipment. A small detail solves a critical problem. The PGD is not required for the Corner-Lock system as it has a 1/4-20 Fastener with paint cutting teeth for Positive Electrical Contact between panel and pedestal. 12 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

ASM Understructure Bridging Options Anchor to Suit Understructure Seismic Bracing Typical Bridging, See Note Below Stringer System 1/8" Thick x 2" Underfloor Steel Brackets Obstruction Raised Access Floor Panels 5/16"-18 x 1" Bolt and Nuts 1/8" Thick x 2" Steel Brackets 5/16"-18 x 1" Bolt and Nuts SBBA-1C e y Over Under Obstruction Seismic Bracing for Round Base Tubes Can Be Used As A Single Brace Or As A Double Brace Assembly Plan View Pedestal On Top of Bridging Plan View SBBA-1C Seismic Brace Bracket Assembly T PRIOR NOTICE. NOTE: DATA SHEET DRAWING AND INFORMATION ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. DBT1-nn Type 3 Diagonal Brace Tube 1" O.D. x 16 4-1110 FAX: 843-534-1111 Ga. HD Galv. Steelwww.asmproducts.com R ASM Modular Systems Inc. 9500 Industrial Center Dr. Ladson, SC 29456 TEL: 843-534-1110 FAX: 843-534-1111 www.asmproducts.com ACS - 2723 Bridging Options Typical Anchor to Suit Bridging, See ACS - 2723 Over Underfloor Obstructions Pedestal System Stringer System Note Below Underfloor Obstruction Raised Access Floor Panels Pedestal On Top of Bridging Understructure Bridging Bridging Options 1/8" Thick x 2" Steel Brackets Over Underfloor Obstructions 5/16"-18 x 1" Bolt and Nuts Pedestal System Typical Bridging, See Note Below Can Be Used As A Single Brace Or As A Double Brace Assembly Underfloor Obstruction Plan View Trench Raised Access Floor Panels Bridging atpedestal TopOnofTopSub Floor Bridging to Extend ofbeyond Trench on Each Side, See Note Below NOTE: DATA SHEET DRAWING AND INFORMATION ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. R ASM Modular Systems Inc. 9500 Industrial Center Dr. Ladson, SC 29456 TEL: 843-534-1110 FAX: 843-534-1111 www.asmproducts.com Trench Stringer System ACS - 2723 Bridging at Top of Sub Floor to Extend Beyond Trench on Each Side, See Note Below Pedestal System Bridging Note: C-Channel or I-Beam Structural Steel, Size and Spacing to be Engineered for Required Floor Loads NOTE: DATA SHEET DRAWING AND INFORMATION ARE SUBJECT TO CHANGE WITHOUT PRIOR NOTICE. ACS - 9254A ASM Modular Systems Inc. R 9500 Industrial Center Dr. Ladson, SC 29456 TEL: 843-534-1110 FAX: 843-534-1111 www.asmproducts.com Helping you become & Engineering + USA QualityWITHOUT & Testing NOTE: DATA SHEET DRAWINGUSA AND Design INFORMATION ARE SUBJECT TO CHANGE PRIOR NOTICE. GLOBAL VISION Trench LEED Certified ASM Modular Systems Inc. R Bridging Note: C-Channel or I-Beam Structural Steel, Size and Spacing to be Engineered for Required Floor Loads Data Center Catalog Bridging at Top of Sub Floor to Extend Beyond Trench on Each Side, See Note Below 13 ACS

ASM Finishes Flooring Finishes High Pressure Laminate (HPL) 2103 2201-1 2202 2203 2204 2205 2206 2207 2208 Properties NEMA Test Method NEMA Standard ASM Laminate Results Electrical Resistance NFPA 99-1.0 x10 6-2.0 x 10 10 Stain Resistance 3.4 No effect No effect Boiling Water Resistance 3.5 No effect No effect High Temp. Resistance 3.6 Slight effect No effect Wear Resistance 3.13 3000 cycles/min. 3000 + Scuff Resistance 3.16 No effect No effect Vinyl Plastic Technologies (VPT) 3160-Platinum 3161-Mint 3162-White 3163-Yellow 3164-Tundra 3165-Wintergreen 3166-Ice 3167-Diamond 3168-Cloud 3169-Glacier Performance Conductive Static Dissipative Resistance: point to ground 2.5 x 10 4 to 10 6 Ω 10 6 Ω to 10 8 Ω Resistance: point to point 2.5 x 10 4 to 10 6 Ω Static Decay 5000 to 0 volts in < 0.01 sec 5000 to 0 volts in < 0.2 sec VPT Sizes: 24 inch x 24 inch, 12 inch x 12 inch, 60 cm x 60 cm, 30 cm x 30 cm, Custom size if requested 14 ASM Innovations in access flooring (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Dr., Ladson, SC 29456

Accessories Solid and Airflow Lifter Kit Designed to make installations and alterations simple. They can be easily stored on Lifter Wall Mount Brackets. Rails The ASM Handrail System is a modular clear anodized extruded aluminum railing. Ramp & Steps Modular components for any size or application. Logo Panels Custom designs and logos incorporated into laminate finish. Grommets Round, square, and brush type in a multitude of sizes. Seismic Braces For high risk seismic projects, ASM offers seismic braces that can easily be attached to any ASM raised floor pedestal for ultimate lateral support. Clear View Panel High strength acrylic allows you to monitor underfloor area without removing panels. Electrical Box Multiple floor box options integrated into panel system. Frost-Byte Booster unit for air grate where underfloor pressure is insufficient. Helping you become LEED Certified USA Design & Engineering + USA Quality & Testing GLOBAL VISION Data Center Catalog 15

In addition to being the largest access flooring manufacturer in the world, the Kingspan group is a major manufacturer of an integrated range of products for the construction industry. The Group continues to innovate and improve on an existing product range, and have done so successfully for over 30 years. These innovations are clearly seen within Kingspan s emphasis on modern Methods of Construction and importance on increasingly sustainable buildings. The Group s companies have a presence around the world that is ever increasing. For more information about Kingspan please visit us at www.kingspan.com. Flexibility, Strength, and Energy Savings (888) 279-9216 Toll Free (843) 534-1110 Local (843) 534-1111 Fax 9500 Industrial Center Drive Ladson, South Carolina 29456 USA www.asmproducts.com Manufacturing Sales Distribution WORLDWIDE