Uniform Building Code For Head-of-Wall, Vertical Shaft Walls and Wall Backing Excerpts from the 1997 Uniform Building Code

Similar documents
Following contains common verbiage found in major model building codes and has been edited for the purpose of inclusion on this CD.

The System Slotted Deflection Track (pat# 5,913,788)

ASTM E Fire Tests of Building Construction and Materials* Protective Structures, Ltd. Bullet-Resistant FRP Panel

Excerpts from the Uniform Building Code. (UBC) For The US

FIRE AND SMOKE PROTECTION FEATURES

SECTION 702 DEFINITIONS

FIRE AND SMOKE PROTECTION FEATURES

FIRE-RESISTANCE-RATED CONSTRUCTION

FIRE AND SMOKE PROTECTION FEATURES

2012 IBC Inspection of Fire-resistance Rated Walls

CHAPTER 26 PLASTIC SECTION BC 2601 SECTION BC 2603 GENERAL FOAM PLASTIC INSULATION

Building Codes and Ordinances ARC 227

SIDEWALK & RAILING REPLACEMENT BOARD OF ED BUILDING

PLASTIC CHAPTER 26. SECTION 2602 DEFINITIONS Definitions. The following terms are defined in Chapter

To whom it may concern. RE: Certificate for Rainbow Attic Stair Model ProTech-12 (Model # PT ) 75 Minute Fire Rating

FS , 712, 713, 714

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

LEGACY REPORT Reissued October 1, Legacy report on the BOCA National Building Code/1999

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings. John Buddy Showalter, PE VP, Technology Transfer American Wood Council

Code Compliance for Fire Resistance-Rated Assemblies in Light-Frame Buildings

CHAPTER 26 PLASTIC SECTION 2601 SECTION 2603 GENERAL FOAM PLASTIC INSULATION

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

2015 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

&02.1. Level 3 Alterations. Level 3 Alterations shall comply with Sections & and &

FCIA Webinar Gypsum Wall Patching

SECTION NON-STRUCTURAL METAL FRAMING

June 7, 2012 PARTIES INTERESTED IN HVAC DUCT ENCLOSURE ASSEMBLIES

VERTICAL OPENINGS STUDY GROUP REPORT TO CTC MEETNG CHICAGO, IL - OCTOBER 13-14, 2011 CODE CHANGES

STATEMENT OF SPECIAL INSPECTION FORM

DECK PERMIT APPLICATION

2009 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

Stone and Masonry Veneer

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

FIRE ENDURANCE RATINGS CLAY BRICK MASONRY

ACCEPTANCE CRITERIA FOR ROOF UNDERLAYMENT FOR USE IN SEVERE CLIMATE AREAS PREFACE

General Building Information

ACCESSIBLE REST ROOM Code Requirements

Schedule A. a representative appointed from among persons nominated by the Nova Scotia Accessibility Advisory Board.

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 Virginia Residential Code

Advanced Studies of the International Building Code. Presented by Steve Thomas, Colorado Code Consulting, LLC

2012 IBC Inspection of Fire-Resistance Rated Floors, Ceilings and Roofs

Interior FRT Wood. References of Previous Model Building Codes

RE: Evaluation of a Comparison of ASTM 119 on steel to BS 476 Pt 20/21/22

Typical Deck Details. Albemarle County, Virginia. Based on the 2012 Virginia Residential Code

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

SECTION R327.3 STANDARDS OF QUALITY

2. Does not require, involve or include any additions to, or repair or modification of, the existing foundation.

311.7 Stairways Width Headroom. Exception: Walkline Stair treads and risers Tread depth.

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Typical Deck Details. Shenandoah County, Virginia. Based on the 2012 International Residential Code

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Boston & Waltham Workshops, December 6 & 7, 2017

ORDINANCE NO. _ 10463

Protecting Penetrations in Fire Rated Construction

2015 IBC Exit Systems

Engineering. The ins and outs of grab bars. by Aleta A. Nitschke, CHA

2012 International Building Code Errata (Portions of text and tables not shown are unaffected by the errata)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

Adult Family Home Inspections

CALIFORNIA BUILDING PLANS EXAMINER CONTENT OUTLINE 01. GENERAL ADMINISTRATION 3 % Project Administration 3%

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES EVALUATION CRITERIA FOR

SECTION GYPSUM WALLBOARD SYSTEMS. A. Gypsum board at new wall partitions or where indicated on drawings. B. ASTM C442 - Gypsum Backing Board

Shaft Wall Solutions for Wood-Frame Structures. Ricky McLain, PE, SE WoodWorks Wood Products Council Charlotte WSF, November 2, 2017

FIRE RESISTANCE TESTS OF BRICK VENEER / WOOD FRAME WALLS J. GREGG BORCHELT

2003 International Building Code Errata

2006/2007 PROPOSED CHANGES TO THE INTERNATIONAL BUILDING CODE C FIRE SAFETY FIRE SAFETY CODE COMMITTEE

SPECIAL INSPECTION AGREEMENT

HOUSING CONVERSION Guidelines for the conversion of a house to commercial use.

HCD DSA OSHPD 1 2 1/AC AC SS SS/CC CALIFORNIA BUILDING CODE 301

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

Code Change No: FS43-06/07

HILLSBOROUGH TOWNSHIP CODE ENFORCEMENT

Wood Decks Zoning and construction requirements for open non-sheltered wood decks for residential dwellings

Updated references to SEI/ASCE 7 to the 2016 edition once it is available.

Standard for Bleachers, Folding and Telescopic Seating, and Grandstands

Project Address Applicant: (Please Print) Plan review Engineer: Phone: Date

Multi-Institutional Academic Health Science & Research Center Evansville, IN

HOOVER TREATED WOOD PRODUCTS, INC. TECHNICAL NOTE FOR ADDITIONAL INFORMATION: TEC-WOOD ( )

DIIM & Firestopping. Firestopping Joints FCIA 2018

CHAPTER 6 TYPES OF CONSTRUCTION

Union County Vocational - Technical Schools Scotch Plains, New Jersey

WINDOW AND DOOR REPLACEMENT SAMPLE PLAN

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:

EXIT ACCESS RAMP. An interior ramp that is not a required interior exit ramp.

Plan Check No. f) Where only half baths are provided, at least one half bath. g) Carports, garages or parking spaces. (1111B.4.2.

The System U.S. Patent No. 5,913,788

This worksheet must be signed by the architect or engineer of record for the entire project for commercial or mixed-use buildings.

July 23, 2010 PARTIES INTERESTED IN REFLECTIVE FOIL INSULATION

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

WOOD USE IN NONCOMBUSTIBLE BUILDINGS

Masonry and Cold-Formed Steel Requirements

E?? , , , , , , , , , , , , Table ,

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

SECTION ALUMINUM GATES

ACCEPTANCE CRITERIA FOR METAL PLASTER BASES (LATH) PREFACE

INTERNATIONAL BUILDING CODE - ADOPTION AND AMENDMENTS Effective July 1, 2004

INTERIOR FINISHES CHAPTER 8

SUPPLEMENTAL ACCESSIBILITY NO. 4 PLAN REVIEW CHECKLIST

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

Technical Note. Flat Plate Voided Concrete Slab Systems

INTERIOR FINISHES CHAPTER 8

Transcription:

For Head-of-Wall, Vertical Shaft Walls and Wall Backing Excerpts from the 1997 FIRE-RESISTIVE JOINT SYSTEM is an assemblage of specific materials or products that are designed, tested and fire resistive in accordance with UBC Standard 7-1 to resist, for a prescribed period of time, the passage of fire through joints. SECTION 706 - FIRE-RESISTIVE JOINT SYSTEMS 706.1 General. Joints installed in or between fire-resistive walls, fire-resistive floor or floor-ceiling assemblies and fire-resistive roof or roof-ceiling assemblies shall be protected by an approved fire-resistive joint system designed to resist the passage of fire for a time period not less than the required fire-resistance rating of the floor, roof or wall in between which it is installed. Fireresistive joint systems shall be tested in accordance with Section 706.2. EXCEPTION: Fire-resistive joint systems are not required for joints in the following locations: 1. Floors within a single dwelling unit. 2. Floors where the joint is protected by a shaft enclosure in accordance with Section 711. 3. Floors with atriums where the space adjacent to the atrium is included in the volume of the atrium for smoke-control purposes. 4. Floors within malls. 5. Floors within open parking structures. 6. Mezzanine floors. 7. Walls that are permitted to have unprotected openings. 8. Roofs where openings are permitted. Such material or construction assembly shall be securely installed in or on the joint for its entire length so as not to dislodge, loosen or otherwise impair its ability to accommodate expected building movements and to resist the passage of fire and hot gases. 706.2 Fire-resistive Joint Systems. Fire-resistive joint systems shall be tested in accordance with UBC Standard 7-1 under the following conditions: 1. Joint systems shall be installed full height in wall assemblies and full length in floor and roof assemblies. 2. Floor and roof assemblies shall be tested with a minimum positive pressure differential of 0.01 inch of water column (2.5 Pa). 3. Wall assemblies shall be tested with a minimum positive pressure differential of 0.01 inch of water column (2.5 Pa) measured at the mid-height of the wall assembly. 4. Joint systems shall contain a splice. For wall assemblies, the splice shall be located above the mid-height of the wall assembly. Page 1 of 1

5. Joint systems shall be tested at the maximum joint width for which they are designed. Joint systems designed to accommodate movement shall be expanded to the maximum joint opening width for which they are intended to function. 6. Joint systems designed to be load-bearing shall be loaded to the maximum design load in accordance with their intended application. 7. Joint systems designed to accommodate movement shall be preconditioned by cycling between the minimum and the maximum joint opening width for which they are intended to function for the number of cycles specified in Table 7-D. 8. Nonsymmetrical wall joint systems shall be tested in accordance with Sections 706 and 709.5. Table 7-D PRECONDITIONING CYCLES FOR FIRE RESISTIVE JOINT SYSTEMS Type of Joint System Number of Cycles Expansion/Contraction 500 Seismic 100 Wind Sway 500 Shaft Wall Enclosures Excerpts from the 1997 and 1998 California Building Code SECTION 711 - SHAFT ENCLOSURES 711.1 General. Openings through floor shall be enclosed in a shaft enclosure of fire-resistive construction having the time period set forth in Table 6-A for "shaft enclosures" except as permitted in Section 711.3, 711.5 and 711.6. See also Section 304.6 for shafts in Group B Occupancies, Section 306.6 for shafts in Group F Occupancies, Section 307.6 and 307.11.2.3 for shafts in Group H Occupancies, Section 309.6 for shafts in Group M Occupancies and Section 311.6 for shafts in Group S Occupancies. Page 2 of 2

711.2 Extent of Enclosures. Shaft enclosures shall extend from the lowest floor opening through successive floor openings and shall be enclosed at the top and bottom. EXCEPTIONS: 1. Shafts extending through or to the underside of the roof sheathing, deck or slab need not be enclosed at the top. 2. Shafts need not be enclosed at the bottom when protected by fire dampers when conforming to approved recognized standards, installed at the lowest floor level within the shaft enclosure. Shaft enclosures shall be constructed to continuously maintain the required fire-resistive integrity. Excerpts from Table 6-A TABLE 6-A TYPES OF CONSTRUCTION FIRE RESISTIVE REQUIREMENTS (In Hours) For details, see occupancy section in Chapter 3, types of construction sections in this chapter and sections referenced in this table. Building Element TYPE 1 TYPE II TYPE III TYPE IV Noncombustible Noncombustible TYPE IV Fireresistive Fireresistive 1-Hr N 1-Hr N H.T. 1-Hr N 6. Shaft Enclosures 2 2 1 1 1 1 1 1 1 Page 3 of 3

UNIFORM BUILDING CODE (UBC) 1997 CALIFORNIA BUILDING CODE (CBC) 1998 HANDRAIL, GRAB BAR, TUB AND SHOWER SEAT BACKING REQUIRMENTS CBC Table 16-B Handrail Vertical and Horizontal Load "The mounting of handrails shall be such that the completed handrail and supporting structure are capable of withstanding a load of at least 200 pounds (890 kn) applied in any direction at any point on the rail." UBC Section 1106.6.3 Grab bar and Seat Reinforcement "Where walls are located to permit installation of grab bars and seats complying with Section 4.17.4, 4.21.4, 4.22.3, or 4.22.4 of CABO/ANSI A117.1, reinforcement shall be provided for the installation of grab bars and seats." CBC 1115B.6.1.2 Seat An in-tub seat or a seat at the head end of the tub shall be provided as shown in Figures 11B-8 and 11B-9B. The structural strength of seats and attachments shall comply with Section 1115B.8.3. Seats shall be mounted securely and shall not slip. CBC 111B.6.1.3 Grab bars Grab bar complying with Sections 115B.8.2, 1115B.8.3, and 1115B.8.4 shall be provided as shown in figures 11B-9A and 11B-9B. CBC Section 1115.B.8.3 Structural Strength. "The structural strength of grab bars, tub and shower seats, fasteners and mounting devious shall meet the following specifications: Bend stress in a grab bar or seat induces by the maximum bending moment from the application of a 250 pound 1112 N) point load shall be less than the allowable stress for the material of the grab bar or seat. Shear stress inducted in a grab bar or seat by the application of a 250 pound (1112 N) point load shall be less than the allowable shear stress for the material of the grab bar or seat, and its mounting bracket or other support is considered be fully restrained, then direct and torsional shear stresses shall not exceed the allowable shear stress. Page 4 of 4

Shear force induced in the fastener or mounting device from the application of a 250 pound (1112 N) point load shall be less than the allowable lateral load of either the fastener or mounting device or the supporting structure, whichever is the smaller allowable load. Tensile force induced in a fastener by direct tension force of a 250 pound (1112 N) point load, plus the maximum moment from the application of a 250 pound (1112 N) point load, shall be less than the allowable withdrawal load between fastener and supporting structure. Grab bars shall not rotate within their fittings." REQUIREMENTS OF THE AMERICANS WITH DISABILITIES ACT (ADA) CODE Federal register/vol. 56, No. 144/Friday, July 26, 1991 final rule Section 36.401 implements the new construction requirements of ADA. The act includes a failure to design and construct facilities for first occupancy later than 30 months after the date of enactment (i.e., after January 26, 1993). Paragraph 36.401 (A) (1) restates the general requirement for accessible new construction. "Any public accommodation or other private entity responsible for design and construction must ensure that facilities conform to this requirement". 4.26 Handrails, grab bars and tub and shower seats. 4.26.3 Structural strength. 1. Bending stress in a grab bar or seat induced by the maximum bending moment from the application of 250 LBF shall be less than the allowable stress for the material of the grab bar or seat. 2. Shear stress induced in a grab bar or seat by the application of 250 LBF shall be less than the allowable shear stress for the material of the grab bar or seat. If the connection between the grab bar or seat and its mounting bracket or other support is considered to be fully restrained, then direct and torsional shear stresses shall be totaled for the combined shear stresses, which shall not exceed the allowable shear stress. 3. Shear force induced in a fastener or mounting devise from the application of 250 LBF shall be less than the allowable lateral load of either the fastener or mounting device or the supporting structure, whichever is the smaller allowable load. 4. Tensile force induced in a fastener by a direct tension force of 250 LBF plus the maximum moment from the application of 250 LBF shall be less than the allowable withdrawal load between the fastener and the supporting structure. Page 5 of 5

Wall reinforcement for the future installation of grab bars and handrails shall be installed around toilets, bathtubs, shower stalls and where grab bars are provided. The reinforcement shall be of sufficient length to meet the requirement of the grab bar and handrail installation specified herein. The reinforced wall shall be capable of supporting at least a 250 pound point load. SECTION 7.107 - FIRE-ENDURANCE TEST Standard 7.1 Fire Test Procedures The fire-endurance test on the sample with its applied load, if any, shall be continued until failure occurs, or until the sample has withstood the test conditions for a period equal to that herein specified in the conditions of acceptance for the given type of construction. For the purpose of obtaining additional performance data, the test may be continued beyond the time the fire-endurance classification is determined. SECTION 7.108 - HOSE STREAM TEST 7.108.1 General. Where required by the conditions of acceptance, a duplicate sample shall be subjected to a fire-exposure test for a period equal to one half of that indicated as the resistance period in the fire-endurance test, but not for more than one hour, immediately after which the sample shall be subjected to the impact, erosion and cooling effects of a hose stream directed first at the middle and then at all parts of the exposed face, changes in direction being made slowly. 7.108.2 Exemption. The hose stream test shall not be required in the case of constructions having a resistance period, indicated in the fire-endurance test, of less than one hour. 7.108.3 Optional Program. The submitter may elect, with the advice and consent of the testing body, to have the hose stream test made on the sample subjected to the fire-endurance test and immediately following the expiration of the fire-endurance test. 7.108.4 Stream Equipment and Details. The stream shall be delivered through a 2 1/2 - inch (64 mm) hose discharging through a National Standard Claypipe of corresponding size equipped with a 1 1/8-inch (28.6 mm) discharge tip of the standard-taper smoothbore pattern without shoulder at the orifice. The water pressure and duration of application shall be as prescribed in Table 7-1-A. 7.108.5 Nozzle Distance. The nozzle orifice shall be 20 feet (6096 mm) from the center of the exposed surface of the test sample if the nozzle is so located that when directed at the center, its axis is normal to the surface of the test sample. If otherwise located, its distance from the center shall be less than 20 feet (6096 mm) by an amount equal to 1 foot (305 mm) for each 10 degrees of deviation from the normal. Page 6 of 6

TABLE 7-1-A CONDITIONS FOR HOSE STREAM TEST WATER PRESSURE AT BASE OF NOZZLE (pounds per square inch) DURATION OF APPLICATION (minutes per 100 sq. feet) EXPOSED AREA Resistance Period x 6.89 for kpa X 0.0108 for min./m2 8 hr and over 45 6 4 hr and over if less than 8 hr 45 5 2 hr and over if less than 4 hr 30 2 1/2 1 1/2 hr and over if less than 1 1/2 hr 30 1 1/2 1 hr and over if less than 1 1/2 hr 30 1 Less than 1 hrs, if desired 30 1 SECTION 7.109 --TIME OF TESTING The material or construction shall not be tested until a large proportion of its final strength has been attained and, if it contains moisture, until the excess has been removed to achieve an airdry condition in accordance with the requirements given in this section. Protect the testing equipment and sample undergoing the fire test from any condition of wind or weather that might lead to abnormal results. The ambient air temperature at the beginning of the test shall be within the range of 50 F to 90 F. The velocity of air across the unexposed surface of the sample, measured just before the test begins, shall not exceed 4.4 feet per second as determined by an anemometer place at right angles to the unexposed surface. If mechanical ventilation is employed during the test, an airstream shall not be directed across the surface of the specimen. Page 7 of 7

TESTS OF NONBEARING WALLS AND PARTITIONS SECTION 7.113 -- SIZE OF SAMPLE The area exposed to fire shall not be less than 100 square feet, with neither dimension less than 9 feet. The test specimen shall be restrained on all four edges. For construction joints, the area of the test specimen may be less than 100 square feet provided the length of the joint is not less than 9 feet. The test specimen shall be of sufficient size so as to produce a representative construction joint for which evaluation is desired. SECTION 7.114 -- CONDITIONS OF ACCEPTANCE The test shall be regarded as successful if the following conditions are met: 1. The wall or partition shall have withstood the fire-endurance test without passage of flame or gases hot enough to ignite cotton waste, for a period equal to that for which classification is desired. 2. The wall or partition shall have withstood the fire and hose stream test as specified in Section 7.108, without passage of flame, of gases hot enough to ignite cotton waste, or of the hose stream. The assembly shall be considered to have failed the hose stream test if an opening develops that permits a projection of water from the stream beyond the unexposed surface during the time of the hose stream test. 3. Transmission of heat through the wall or partition during the fire-endurance test shall not have been such as to raise the temperature on its exposed surface more than 250 F above its initial temperature. Page 8 of 8