Bond performance of patching materials subjected to environmental effects

Similar documents
DURABILITY PERFORMANCE OF EPOXY INJECTED REINFORCED CONCRETE BEAMS WITH AND WITHOUT FRP FABRICS

Performance of NSM FRP strengthened concrete slabs at low temperatures

BOND PERFORMANCE OF STEEL REINFORCED POLYMER AND STEEL REINFORCED GROUT

OUT OF PLANE BEHAVIOR OF MASONRY INFILL WALLS RETROFITTED WITH A REINFORCED POLYMER GRID AND POLYUREA SYSTEM

Debonding Behavior of Skew FRP-Bonded Concrete Joints

Strengthening of an Impact-Damaged PC Girder

Ultimate strength prediction for reinforced concrete slabs externally strengthened by fiber reinforced polymer (FRP)

CFRP STRENGTHENING OF CONCRETE BRIDGES WITH CURVED SOFFITS

SHEAR PERFORMANCE OF RC MEMBERS STRENGTHENED WITH EXTERNALLY BONDED FRP WRAPS

EXPERIMENTAL NON-DESTRUCTIVE TESTING OF FRP MATERIALS, INSTALLATION, AND PERFORMANCE, DALLAS COUNTY BRIDGE, MISSOURI, USA

SHEAR AND BUCKLING STRENGTHENING OF STEEL BRIDGE GIRDER USING SMALL-DIAMETER CFRP STRANDS

Strengthening of Reinforced Concrete Beams using Near-Surface Mounted FRP Mohamed Husain 1, Khaled Fawzy 2, and Mahmoud Nasr 3

STRENGTHENING OF INFILL MASONRY WALLS USING BONDO GRIDS WITH POLYUREA

13 TH C ANADIAN M ASONRY S YMPOSIUM H ALIFAX, C ANADA JUNE 4 TH JUNE 7 TH 2017 SEISMIC PERFORMANCE OF REINFORCED MASONRY WALLS STRENGTHENED

CERTIFIED TEST REPORT

Deflection Assessment of an FRP-Reinforced Concrete Bridge. By Danielle K. Stone, Andrea Prota, and Antonio Nanni

AN OVERVIEW OF COMPOSITES USAGE IN BRIDGE FACILITIES IN THE STATE OF MISSOURI, USA

STEEL REINFORCED POLYMER: AN INNOVATIVE AND PROMISING MATERIAL FOR STRENGTHENING THE INFRASTRUCTURES

STRENGTHENING OF UNBONDED POST-TENSIONED CONCRETE SLABS USING EXTERNAL FRP COMPOSITES

BEHAVIOR OF 40 YEAR-OLD PRESTRESSED CONCRETE BRIDGE GIRDERS STRENGTHENED WITH CFRP SUBJECTED TO CYCLIC LOADING

RESEARCH ON COMPOSITE STRENGTHENING OF MASONRY ARCHES

Behaviour of deviated CFRP-Strips

STRENGTHENING OF MASONRY WITH NEAR SURFACE MOUNTED FRP BARS. Abstract

AFFECT OF ENVIRONMENTAL CONDITIONS DURING INSTALLATION PROCESS ON BOND STRENGTH BETWEEN CFRP LAMINATE AND CONCRETE SUBSTRATE

L Shaped End Anchors to Eliminate Premature Plate End Debonding in Strengthened RC Beams

Tests on FRP-Concrete Bond Behaviour in the presence of Steel

NUTC R Adding Faculty in Transportation Areas - Year 2 & 3: Research Progress on Behavior and Design of Concrete Structures

AFRP retrofitting of RC structures in Japan

Field and Laboratory Performance of FRP Bridge Panels

Flexural strengthening of steel I-beams by using CFRP strips

STRENGTHENING OF IMPACT-DAMAGED BRIDGE GIRDER USING FRP LAMINATES

OLD KEYS BRIDGE REPAIRS Negative Moment Strengthening of the Rockland Channel Bridge Florida

UPGRADING SHEAR-STRENGTHENED RC BEAMS IN FATIGUE USING EXTERNALLY-BONDED CFRP

DESIGNING FOR TAPERS AND DEFECTS IN FRP-STRENGTHENED METALLIC STRUCTURES

SHEAR STRENGTHENING USING CFRP SHEETS FOR PRESTRESSED CONCRETE BRIDGE GIRDERS IN MANITOBA, CANADA

Strengthening Highway Bridges with CFRP Composites

EFFECT OF VARIED SURFACE ROUGHNESS AND CONCRETE STRENGTH ON THE BOND PERFORMANCE OF FRP FABRICS

EFFECTS OF SUSTAINED LOAD AND FREEZE-THAW EXPOSURE ON RC BEAMS STRENGTHENED WITH PRESTRESSED NSM-CFRP STRIPS

FLEXURAL AND SHEAR STRENGTHENING OF REINFORCED CONCRETE STRUCTURES WITH NEAR SURFACE MOUNTED FRP RODS

Influence of Arching Mechanism in Masonry Walls Strengthened with FRP Laminates

BEHAVIOR OF FRP SANDWICH PANELS FOR TRANSPORTATION INFRASTRUCTURE

INFLUENCE OF ARCHING MECHANISM IN MASONRY WALLS STRENGTHENED WITH FRP LAMINATES. Abstract

CENTER FOR INFRASTRUCTURE ENGINEERING STUDIES

FRP REPAIR TECHNIQUES FOR R.C. BEAMS PRE-DAMAGED IN SHEAR

IN-PLANE BEHAVIOR OF ALTERNATIVE MASONRY RETROFITTED WITH POLYUREA MEMBRANES

s urfa c e mo unted C FR P rods by s ta tic a nd dyna mic

INFLUENCE OF WATER IMMERSION ON THE BOND BEHAVIOR BETWEEN CFRP AND CONCRETE SUBSTRATE

IMPROVING SHEAR CAPACITY OF RC BEAMS USING EPOXY BONDED CONTINOUS STEEL PLATES

Experimental investigation of the use of CFRP grid for shear strengthening of RC beams

STATIC AND FATIGUE PERFORMANCE OF 40 YEAR OLD PRESTRESSED CONCRETE GIRDERS STRENGTHENED WITH VARIOUS CFRP SYSTEMS

AN IMPROVED COMPOSITE ANCHORING SYSTEM

SEISMIC STRENGTHENING AND REPAIR OF REINFORCED CONCRETE SHEAR WALLS

FLEXURAL BEHAVIOR OF RC BEAMS REINFORCED WITH NSM AFRP RODS

FRP STRENGTHENING OF 60 YEAR OLD PRE-STRESSED CONCRETE BRIDGE DECK UNITS

DEBONDING STRENGTH OF STEEL JOINTS STRENGTHENED USING STRAND CFRP SHEETS UNDER AXIAL TENSION

SEISMIC RETROFITTING OF REINFORCED CONCRETE BRIDGE FRAMES USING EXTERNALLY BONDED FRP SHEETS

EXPERIMENTAL STUDY ON DOUBLE LAP JOINTS COMPOSED OF HYBRID CFRP/GFRP LAMINATE

Concrete-filled fiber reinforced polymer tube-footing interaction in bending

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

Flexural Behavior of RC T- Section Beams Strengthened with Different Configurations of CFRP Laminates

THE EFFECT OF FATIGUE LOADING ON BOND STRENGTH OF CFRP BONDED STEEL PLATE JOINTS

Seismic Evaluation and Retrofit of Beam- Column Joints of Mid-America Bridges Part 2: Steel Sheet and Plate Retrofit

CHAPTER III METHODS AND MATERIALS

PRE-CONSTRUCTION INVESTIGATION FOR THE REHABILITATION OF A BRIDGE USING INTERNAL FRP TECHNOLOGIES

INTERNATIONAL JOURNAL OF CIVIL AND STRUCTURAL ENGINEERING Volume 3, No 1, 2012

THE DESIGN OF EXTERNALLY BONDED REINFORCEMENT (EBR) FOR REINFORCED CONCRETE STRUCTURES BY MEANS OF FIBRE REINFORCED POLYMERS (FRP)

APPLICATION OF PRE-STRESSED UN-BONDED CFRP FOR STRENGTHENING OF METALLIC STRUCTURES

EXPERIMENTAL INVESTIGATION OF CFRP STRENGTHENED DAMAGED STEEL PLATES SUBJECTED TO STATIC LOADING

FRP Anchorage Systems for Infill Masonry Structures

Flexural Behaviour of Composite Girders Using FRP and Precast Ultra-High-Strength Fiber-Reinforced Concrete Slabs

BEHAVIOUR OF RC BEAMS STRENGTHENED WITH NSM STEEL AND CFRP BARS

BEHAVIOR OF REINFORCED CONCRETE ONE-WAY SLABS STRENGTHENED BY CFRP SHEETS IN FLEXURAL ZONE

International Journal of ChemTech Research CODEN (USA): IJCRGG ISSN: Vol.7, No.5, pp ,

PASSIVE AND ACTIVE NEAR-SURFACE MOUNTED FRP RODS FOR FLEXURAL STRENGTHENING OF RC BEAMS. Abstract

Application of Tensioned CFRP Strip Method to an Existing Bridge

DEVELOPMENT OF ANCHORAGE SYSTEM FOR CFRP SHEET IN STRENGTHENING OF REINFORCED CONCRETE STRUCTURES

Strengthening of Continuous SCC Hollow Beams under Shear Stresses Using Warped CFRP Strips

Strengthening of Timber Bridges

Numerical Study on Interaction between Steel Stirrups and Shear- Strengthening NSM FRP Strips in RC Beams

Unidirectional Carbon Fibre Anchorage Length Effect on Flexural Strength Capacity For Concrete Beams

Fiber Reinforced Polymer Repair Techniques for Reinforced concrete Beams Pre-Damaged in Shear

FRP-strengthened RC Structures

Behaviour of Post-Installed GFRP Adhesive Anchors in Concrete

Investigation into the Bond between CFRP and Steel Plates

Constitutive Models of Prestressed Steel-Fiber Concrete

Assessment of Long-Time Behavior for Bridge Girders Retrofitted with Fiber Reinforced Polymer

Experimental study on mechanical behaviors of damaged RC beams after reinforcement

Seismic Retrofit Of RC Columns With Inadequate Lap-Splice Length By External Post-Tensioned High-Strength Strips

3. TEST METHOD FOR BOND PROPERTIES OF CONTINUOUS FIBER SHEETS TO CONCRETE (JSCE-E )

Seismic Behavior of Shear-Critical Reinforced Concrete Frame: Experimental Investigation

Laser Profilometry For Concrete Substrate Characterization Prior to FRP Laminate Application

EXPERIMENTAL ANALYSIS OF CENTERALLY OPENNED TWO- WAY SLABS STRENGTHENED WITH CARBON FIBER LAMINATES

STRENGTHENING STEEL-CONCRETE COMPOSITE BRIDGES WITH HIGH MODULUS CARBON FIBER REINFORCED POLYMER (CFRP) LAMINATES

RESPONSE OF SUBSTANDARD REINFORCING DETAILS T CONNECTIONS UPGRADED WITH CONCRETE COVERS AND CFRP

GROUND ANCHOR TENDONS IN CARBON FIBRE-REINFORCED POLYMERS

Effect of prestressed CFRP plate location on behavior of RC beam strengthened with prestressed CFRP plate

BASIC CHARACTERISTICS OF FRP STRAND SHEETS AND FLEXURAL BEHAVIOR OF RC BEAMS STRENGTHENED WITH FRP STRAND SHEETS

Mechanical Behaviour of Concrete Beams Reinforced with CFRP U- Channels

Glass fibre reinforced textile composites strengthening solutions for masonry arches

Transcription:

Fourth International Conference on FRP Composites in Civil Engineering (CICE28) 22-24July 28, Zurich, Switzerland Bond performance of patching materials subjected to environmental effects W. Moore & J.J. Myers Missouri University of Science and Technology (Missouri S&T), Rolla, Missouri, USA ABSTRACT: This study investigated the bond strength between concrete patching materials and fiber reinforced polymer (FRP) laminates used in the repair of impact damaged girders. Research was performed to understand how the FRP substrate-bond is affected by using different commercially available patching materials and environmental conditioning methods under sustained load. s included the selected patching material, the conditioning exposure and the level of sustained loading. Using the results an effective bond length for each material was obtained and an understanding of the overall bond strength was determined. 1 INTRODUCTION Over the last several years FRP has been increasingly used in the repair of impact damaged prestressed concrete (PC) members. These materials have been extensively researched in their ability to repair and bond with concrete members; however, very little research has been done to investigate the effectiveness of bond between FRP and the patching materials used for impact damaged members within this process. This project accessed the bond performance of patching materials while also studying the effects of environmental conditioning and sustained loading. A typical example for the use of this patching process in the field is the retrofit of highway overpass girders. Many times large vehicles that do not meet the clearance requirements attempt to pass under the overpass and incur damage to the girder overhead. To restore the original capacity to these damaged members, engineers use FRP and patching materials. The patching material is applied to the damaged beam or girder and then it is wrapped in FRP sheets or laminates. This results in the restoration of the ultimate flexural capacity. 2 EXPERIMENTAL PROGRAM 2.1 Material Properties The FRP selected for testing had a tensile strength of 5,5 kg/cm 2 (55 ksi), a design modulus of 2.5x1 6 kg/cm 2 (, ksi) and a design thickness of.165 mm/ply (.65 in/ply). The patching materials tested were Verticoat Supreme (EUCO-Euclid Chemical Company), Burke V/O Patch (Edoco), and TPM72 (General Polymers) which had compressive strengths of 142 kg/cm 2 (216 psi), 49 kg/cm 2 (6965 psi) and 64 kg/cm 2 (5185 psi) respectively. Each of these materials are specifically marketed and used for concrete repair of damaged concrete members. 2.2 Specimen Preparation The specimens tested consisted of two concrete blocks, 152.4 mm x 152.4 mm x 4.8 mm (6 in. x 6 in. x 12 in.). One of which was poured with two 12.7 mm x 11.6 mm x 4.8 mm (½ in. x 4 in. x 12 in.) grooves, one on each side, to accommodate the patching material. The solid block was used as an anchor for the shear bond test setup. The patching material was applied to - 1 -

the grooves of the grooved block. The materials chosen were ones that are used in vertical applications for repairing damaged concrete structures. FRP was attached to the patching material and connected to the anchor block laterally on both sides as shown in Figure 1. To avoid edge effects, a 5.8 mm (2 in.) strip was left unbonded on the inside of the specimen. The strip itself was 99.6 mm (5 in.) long with 81 mm (15 in.) of spacing between the anchored block and the specimen. To guarantee bond failure would occur on the monitored side of the specimen, an additional FRP wrap was attached to both sides of the anchor block. Figure 1. Specimen setup prior to any loading or environmental conditioning. 2. Surface Roughening To ensure bonding between the concrete and patching material, the blocks were roughened with a wire brush as specified by the preparation directions of each patching material. The surface of the patching material was also roughened prior to application of the FRP. This was performed by using a wire brush attached to a grinder. The Verticoat Supreme material roughened the best, followed by the TPM72, and then the Burke V/O Patch. The Burke V/O Patch was actually very difficult to roughen and did not yield as distinct results as the Verticoat Supreme. Higher levels in roughness resulted in higher failure loads during the testing portion of the experiment. The three blocks can be seen in Figure 2. Figure 2. Surface preparation (left to right: Verticoat Supreme, TPM72, & Burke V/O Patch). 2.4 Environmental Conditioning and Loading For each patching material, twelve (12) specimens were tested using six (6) combinations, thus producing a set of two specimens per condition. Of those twelve (12), six (6) were conditioned in an environmental chamber, four (4) were exposed to ambient winter conditions for six weeks and conditioned naturally in Rolla, Missouri, USA, and two (2) were stored under laboratory conditions to serve as control specimens. The conditioned specimens were cycled in the environmental chamber for four weeks. During this time they underwent 112 conditioning cycles. A cycle began at 4 degrees C (4 degrees F) and then slowly decreased to -18 degrees C (-1 degrees F) in one hour. It was then soaked at that temperature for two hours, before it began an hour long increase back up to 4 degrees C (4 degrees F). Four cycles were performed each day. Figure represents the environmental conditioning performed in the environmental chamber. Along with variance of environmental effects, the specimens were also subjected to different sustained loadings. These acceptable sustained loading levels were determined by the ultimate tensile strength of a 5.8 mm (2 in.) strip of FRP and the associated bond strength of a control - 2 -

specimen which failed at 14.1 kn (.17 kips). For each material, two (2) of the conditioned specimens were loaded at 1 percent and two (2) at 2 percent of the ultimate tensile capacity of the FRP strip. The two (2) specimens exposed to ambient conditions were loaded at 2 percent. These correspond to 6.6 kn (1.4 kips) and 12.72 kn (2.86 kips) for the 1 and 2 percent sustained loading levels respectively. Figure. Environmental conditioning cycle. Due to a malfunction at the start of the conditioning, three specimens accidentally debonded including a Burke V/O Patch loaded at 1 percent, a Burke V/O Patch loaded at 2 percent and a Verticoat Supreme loaded at 1 percent. It may be noted that there was one fewer test result for these three series of specimens at the aforementioned sustained loading level. The sustained loading setup is illustrated in Figure 4. By tightening the bolt, the spring compressed to load the specimen. A spring compression of 12.7 mm (.5 in.) was equivalent to 2 percent, and 6.5 mm (.25 in.) was equivalent to a 1 percent sustained loading level. This loading level was calibrated in a compression testing machine prior to installation. Figure 4. Schematic of loading setup (left) & actual loading setup (right). 2.5 Test Setup The shear bond test setup can be seen in Figures 5-6. The specimen and attached anchor block were placed on a flat smooth surface to minimize friction, and then a hydraulic ram and load cell were placed in between the two blocks. The specimen was then slowly loaded until bond failure occurred. Four strain gauges were attached to at least one FRP strip for each condition investigated on the monitored block. The remaining blocks in the series had only one strain gauge as illustrated in Figure 6. Figure 5. Schematic of test setup (left) and actual test setup (right). - -

Figure 6. Strain gauge locations for specimens with four gauges (left), and one strain gauge (right). RESULTS Figures 7-9 compare the failure load and peak strain for each variable. The numbers above each bar indicate the standard deviation for the set of each variable. Bars without the notation represent sets where one of the specimens debonded due to the experimental malfunction. Failure Load (kn) Figure 7. Bond failure load and peak strain for the Verticoat Supreme patching material. Failure Load (kn) 21 18 15 12 9 6.64.52.25 Figure 8. Bond failure load and peak strain for the Burke V/O Patch patching material. 18.44.12.52.5 5 455.21 8 15 Failure Load (kn) 21 18 15 12 9 6 12 9 6 1.8 4.9 1.4 1.98.22 Figure 9. Bond failure load and peak strain for the TPM72 patching material. Peak strain (micro-strain) Peak strain (micro-strain) Peak strain (micro-strain) Figures 7-9 also provide a comparative explanation of the failure of the materials. Of the three materials, Verticoat Supreme exhibited the least amount of degradation as illustrated numerically in the Failure Load plots. The largest variance from the control for Verticoat Supreme was 5. percent while Burke V/O Patch had a maximum variance of 21.9 percent, indicating substantial degradation. The TPM72 failure load of the control was lower than most of the 7 6 5 4 2 1 7 6 5 4 2 1 4 2 1 628 442 727 11 81 18 85 66-4 -

specimens. This was likely due to the abnormalities within the test which are discussed later. As noted in Section 2.4, Verticoat Supreme produced the highest debonding failure loads overall, followed by TPM72 and Burke V/O Patch. Typical failure modes for each patching material are illustrated in Figure 1. Debonding in substrate VS Debonding primarily in substrate Debonding at interface Burke Debonding failure at interface Debonding primarily in substrate patching material TPM72 Debonding varied between substrate & interface a. Control specimens b. Conditioned with 2% sustained loading Figure 1. FRP strips after testing for control (left) and conditioned 2 percent (right). 6 5 4 2 1 Verticoat Supreme Control Specimen 1 kn 15. 5 1 15 2 Figure 11. Strain distribution along unbonded and bonded length for Verticoat Supreme patch. 7 6 5 4 2 1 Burke V/O Control Specimen 1 kn 6 5 4 2 1 7 6 5 4 2 1 Verticoat Supreme Conditioned 2% Specimen 1 kn 5 1 15 2 Burke V/O Patch Conditioned 2% Specimen 1 kn 5 1 15 2 25 5 1 15 2 25 Figure 12. Strain distribution along unbonded and bonded length for Burke V/O Patch. 5 4 2 1 TPM72 Control Specimen 1 kn 5 4 2 1 TPM Conditioned Specimen 1 kn 5 1 15 2 25 5 1 15 2 25 Figure 1. Strain distribution along unbonded and bonded length for TPM72. - 5 -

Worthy of note is the fact that the debonding location for the Verticoat Supreme and TPM72 specimens primarily occurred within the patching material substrate; however, for the Burke V/O Patch the debonding failure occurred at the interface between the FRP laminate and the substrate patching material. Naturally, it is more desirable for the failure mode to occur in the substrate, so the full shear capacity of the bond behavior can be realized. Specimens that were conditioned under sustained loading exhibited slightly less favorable debonding surfaces visually. An analysis was also performed to investigate the effective bond length for each patching material. The strain versus distance from the edge of block was plotted for load increments of (562 lbs). The analysis was performed on both the control and the 2 percent conditioned specimen for each material. The results from these plots can be seen in Figures 11-1. Due to the limited number of strain gauges it is difficult to determine the exact effective bond length. However, the obtained results from the physical testing do allow the opportunity to gain an understanding for each material. For the Verticoat Supreme material the effective bond length appears to be no more than 8 mm (.15 in.) for both the control and 2 percent conditioned specimen. The Burke V/O Patch and TPM72 also had effective bond lengths of around 8 mm (.15 in.) based on the selected strain gauge layout for both the control and 2 percent conditioned specimens. However, as the load increased for both cases the bond length also increased to a value of 15 mm (5.9 in.). Overall, the effective bond length for all three patching materials at service level loads behaved similar to bonded FRP to a traditional concrete substrate parent material which has an effective bond length between 76.2 mm ( in.) and 11.6 mm (4 in.). (Myers et al., 27) Within this experiment several abnormalities did exist which may have led to unexpected results. These include the load being slightly off-center, manual load may have not been consistent the entire test, and FRP may not have bonded to the patching material the same on both sides of the block. With any surface testing, errors will occur due to the inability to maintain constancy for each surface. However, with this test every precaution was taken to ensure accurate and consistent results. 4 CONCLUSION In all cases of this investigation there was a slight decrease in overall bond strength for the specimens that were conditioned with sustained load prior to testing. Depending on the patch material this difference was minor in one case or more significant in another case. The sustained loading and conditioning appeared to affect the bond performance at the interface in the case of the Burke V/O Patch material. The Verticoat Supreme material exhibited the most consistent and desirable debonding failure mode within the substrate under the various conditions investigated. This may be attributed to a variation in the composition of the patch material allowing improved penetration of epoxy saturant into the pore structure of the patching material. Based on the physical testing, the effective bond length of the patching materials appeared to be between 76.2 mm ( in.) and 11.6 mm (4 in.) which is similar to conventional concrete. 5 REFERENCES Mantan, M., Nanni, A., Dharani, L., Silva, P., & Tunis, G. 25. Bond Performance of Steel Reinforced Polymer and Steel Reinforced Grout. Proceedings of International Symposium on Bond Behaviour of FRP in Structures (BBFS 25), J.F. Chen and J.G. Teng, Eds. Hong Kong, pp. 125-12. Myers, J.J., Shen, X, & Maerz, N.H. 22. Effect of Varied Surface Roughness, Putty Thickness and Concrete Strength on the Interfacial Bond Strength of FRP to Concrete, CIES Report -41, Univ. of Missouri-Rolla, Rolla, MO. Myers, J.J., Jeffries, J., Shen, X. 27 Effect of Varied Surface Roughness and Concrete Strength on the Bond Performance of FRP Fabrics, Proceedings for 27 Advanced Composites in Construction (ACIC 27), University of Bath, Bath, England, UK, pp 22-244. Tumialan, J.G., Huang, P., & Nanni, A. 21. Strengthening of an Impacted PC Girder on Bridge A162, St. Louis County, MO, Missouri Department of Transportation, Jefferson City, MO. - 6 -