CENTRIA MetalWrap Insulated-Composite Backup Panel System

Similar documents
SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA Concept Series Metal Wall Panels ZINC

CENTRIA EcoScreen Perforated Screen Wall Panels

SECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

SECTION STAINLESS STEEL WALL PANELS

CENTRIA Versawall Factory Foamed Metal Wall Panel System

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

Corium Brick Rainscreen System Specifications

Page 1 of 5

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

Metl-Span FW-120 Formed Metal Wall Panels

CENTRIA Exposed Fastener Series Metal Wall Panels

Architectural Roof and Wall Products Guide Specifications

Metl-Span ShadowRib Formed Metal Wall Panels

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

METL-SPAN HPCI Barrier Insulated Metal Wall Panels

CENTRIA Formawall Graphix Series Insulated Core Metal Wall Panel System

Architectural Roof Products Guide Specifications

CENTRIA Concept Series TM Metal Wall Panels

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

SECTION EXTERIOR GRILLS AND SCREENS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

Architectural Roof Products Guide Specifications

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

Architectural Wall Products Guide Specifications

BEARING METAL STUD FRAMING

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION STANDING SEAM METAL ROOFING

Architectural Roof and Wall Products Guide Specifications

SECTION METAL WALL PANELS

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

Trapezoidal-rib, snap joint, standing seam metal roof panels, with related metal trim and accessories.

[Project Name] Section [ ]

Guideline Specifications

SECTION METAL WALL PANEL SYSTEM

Metl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels

Guide Specification for the OSI QUAD Window and Door Flashing System

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

Metl-Span Exposed Fastener Metal Wall Panels

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION METAL ROOF PANELS

SECTION METAL WALL PANELS

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

Ice Rink Renovation & New Clubhouse

Student Services & Classroom Addition

COMPOSITESIDING

Project Name Project # Project Information

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

Guide Specifications. Metl-Span 7.2 Insul-Rib Wall Panel For Commercial & Industrial Buildings PART 1 GENERAL Master Format Section

North Hanover Township School District North Hanover Township, New Jersey

PROJECT LOCATION SECTION ZINC ALLOY METAL PLATE WALL PANELS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

SECTION METAL WALL PANELS

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

SECTION CEMENTITIOUS SHEATHING

GENERAL SPECIFICATION FOR FIRE RATED APPLICATIONS

Architectural Roof and Wall Products Guide Specifications

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

Louis Armstrong New Orleans International Airport NOAB Project # North Terminal Development Program Phase 1

A. Section includes conventionally glazed aluminum curtain walls installed as stick assemblies.

COLLEGE OF STATEN ISLAND

OSU PROJECT NO PAGE 1 02 NOV 2006 SECTION METAL ROOF PANELS

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

ENVIROBEAM SECTION ENVIRO-ROOF CURBS

SECTION COLD-FORMED METAL FRAMING

SECTION INSULATED CORE METAL WALL PANELS 09/09

238T Aluminum Standing Seam Metal Roof System (SSMRS)

CENTRIA Profile Series Exposed Fastener Metal Roof Panels

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

SECTION ROOFING AND SIDING PANELS

SECTION CEMENTITIOUS WOOD FIBER DECKS

C. All anchors, brackets, and hardware attachments necessary to complete the specified structural assembly, when included within project scope.

Specifications. When specifying metal panel roof systems, roof. system designers and specifiers need to be aware

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICES

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION ALUMINUM STORM WINDOWS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

(Project Location) (your firm's name)

Kodiak AWT Hangar, Kodiak Airport Alaska, Siding Specifications

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Metl-Span Insulated BattenLok Metal Roof Panels

Transcription:

CENTRIA MetalWrap Insulated-Composite Backup Panel System CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA metal wall panel cladding to create a complete rainscreen system solution. In addition MetalWrap system is designed to work with all other cladding materials as the backup system making it an excellent choice when multiple cladding materials are used on a project. The unique composite design of a MetalWrap panel provides an air barrier, vapor barrier, moisture barrier, and thermal insulation with total wall values that exceed code requirements in a single, easy-to-install component. The MetalWrap panel design also eliminates the need for separate batt or board insulation, exterior gypsum board sheathing, air barriers, vapor retarders, and building wraps, while providing the ultimate thermal and moisture control. MetalWrap panels come in a foam composite panel constructed of two roll formed steel faces surrounding and entirely bonded to a closed cell poured in place polyisocyanurate foam core. The exterior steel face is isolated from the interior liner by the foam core, which provides superior thermal performance. The facings and sealants create a vapor, air and moisture barrier and with the foam core provide long-term thermal stability. MetalWrap is designed for use with vertical or horizontal CENTRIA exterior metal panels, including Concept, Cascade, IW, all exposed fasterner profiles, Intercept and and FormaBond. MetalWrap was developed using ATMP - CENTRIA's Advanced Thermal and Moisture Protection building envelope science. Any cladding products utilizing MetalWrap with steel stud construction and interior gypsum board finish are available with overall wall thermal resistance of R-14 and U-.074 (for 2-inch thick) and R-21 and U-.047 (for 3-inch thick ). Consult your local CENTRIA architectural representative for design assistance. Contact CENTRIA, Pittsburgh, PA, (800)759-7474, Email: info@centria.com, www.centria.com for a list of local offices. CENTRIA is a world leader in the manufacture of metal building products and systems for nonresidential walls and roofs. CENTRIA is also a world-class coil coater, providing a wide range of coated products for customers in numerous industries. CENTRIA products appear in the following MasterFormat sections: Section 07 41 13 Metal Roof Panels (SRS3) Section 07 41 16 Insulated Core Metal Roof Panels (Versapanel) Section 07 42 13 Metal Wall Panels (Cascade Metal Panel System, Intercept V-Trac, Intercept Entyre, Paradigm EXP, Concept Series, IW Series, Exposed Fastener Panels) Section 07 42 16 Insulated-Core Metal Wall Panels (Formawall Dimension Series, Formawall Graphix Series, Versawall, Versapanel, Foamwall, Versashield MW) Section 07 42 43 Composite Wall Panels (FormaBond) Specifier: This document is organized according to CSI MasterFormat. Edit section number and title as appropriate to the Project. Bold items require specifier selection. Convert bold to plain text and delete notes before publishing. MetalWrap is a trademark of CENTRIA, Inc. ATMP and FormaBond are registered trademarks of CENTRIA. Page 1 of 12

MasterFormat is a trademark of the Construction Specifications Institute. This document is Copyright 2016 CENTRIA. All rights reserved. Page 2 of 12

SECTION 07 42 17 INSULATED-COMPOSITE BACKUP PANEL SYSTEM PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal wall backup panel system consisting of foamed-insulation-core metal wall panels and accessories. 1.2 RELATED REQUIREMENTS Specifier: Edit list below to correspond to Project. A. Division 05 Section "Cold-Formed Metal Framing" for support framing for metal wall backup panels. B. Division 07 Section "Air Barriers" for transition components to building air barrier at perimeter of metal wall backup panels. C. Division 07 Section "Metal Wall Panels" for exterior wall rainscreen panels applied to metal wall backup panels (07 42 13). 1. Concept Series 2. Cascade Metal Panel System 3. IW Series 4. Exposed Fastener Series 5. Paradigm Custom Metal Panels 6. FormaBond MCM 7. Intercept Entype Modular Metal Panel D. Division 07 Section "Sheet Metal Flashing and Trim" for metal flashing components at openings and perimeter. E. Division 13 Section "Metal Building Systems" for support framing for metal wall backup panels. 1.3 REFERENCES A. Reference Standard Editions: Comply with requirements of specified standards edition cited in applicable building code, or if not cited in code, with requirements of edition current at time of issuing of specifications Specifier: If retaining this optional article, edit list below to correspond to Project. B. American Architectural Manufacturer's Association (AAMA): www.aamanet.org: 1. AAMA 809.2 - Voluntary Specification Non-Drying Sealants C. American Society of Civil Engineers (ASCE): www.asce.org/codes-standards: 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures Page 3 of 12

D. ASTM International (ASTM): www.astm.org: 1. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process 2. ASTM A 755 Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products 3. ASTM A 792/A 792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy- Coated by the Hot-Dip Process 4. ASTM C 920 - Standard Specification for Elastomeric Joint Sealants 5. ASTM C 1363 - Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus 6. ASTM D 1929 - Test Method for Determining Ignition Temperature of Plastics 7. ASTM E 72 - Test Methods of Conducting Strength Tests of Panels for Building Construction 8. ASTM E 84 - Test Methods for Surface Burning Characteristics of Building Materials 9. ASTM E 283 - Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen 10. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference E. FM Global (FM): www.fmglobal.com: Specifier: Retain FM classification in subparagraph below when required for project utilizing CENTRIA MetalWrap panels with 0.019 inch/26 gage (0.48 mm) face and liner. 1. ANSI/FMG 4880 - Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems F. National Fire Protection Association (NFPA): www.nfpa.org: 1. NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components G. Underwriters Laboratories, Inc. (UL): www.ul.com: 1. UL 263 - Fire Tests of Building Construction and Materials 2. UL 723 - Test for Surface Burning Characteristics of Building Materials 1.4 PERFORMANCE REQUIREMENTS A. General: Provide metal wall backup panel system meeting the following performance requirements as determined by a qualified testing agency s application of specified tests on manufacturer s standard assemblies. Specifier: Retain "Recycled Content of Steel Sheet" paragraph when required for general sustainable design requirements of project. B. Recycled Content of Steel Sheet: Postconsumer recycled content plus one-half of preconsumer recycled content not less than 25 percent. C. Structural Performance: Provide metal wall backup panel system fabricated to withstand effects of indicated loads and stresses within limits and under conditions indicated, when tested per ASTM E 72. Page 4 of 12

Specifier: Consult structural engineer and edit below as required by local codes. 1. Wind Load Test: Determine loads based on uniform pressure indicated on the drawings. 2. Deflection Limits Test: Withstand test pressures of 150 percent of inward and outward wind-load design pressures with maximum deflection of 1/120 of the span with no evidence of failure. 3. Seismic Performance Test: Comply with ASCE 7, "Minimum Design Loads for Buildings and Other Structures": Sections 11-23, "Seismic". D. Air Infiltration Test: Maximum 0.01 cfm/sq. ft. (0.05 L/s per sq. m) per ASTM E 283 at a staticair-pressure difference of 1.57 lb./sq. ft. (75 Pa). E. Water Penetration Test: No uncontrolled water penetration at a static pressure of 15 lb./sq. ft. (0.7 kpa) per ASTM E 331. F. Thermal Performance Test: Thermal Resistance (R-value) indicated, per ASTM C 1363, corrected to 15 mph (24.1 k/h) outside and still air inside, as-installed condition including fastening and joints. Specifier: Metal cladding on CENTRIA MetalWrap panels meets requirements for thermal protection of foam plastics in IBC Chapter 26. G. Fire-Test-Response Characteristics: Provide metal wall backup panel system with the following fire-test-response characteristics determined by the indicated test standard as applied by UL or other testing and inspection agency acceptable to authorities having jurisdiction. 1. Surface Burning Characteristics: Not greater than the following, per ASTM E 84 or UL 723, for foam core and interior surface: a. Flame spread index: 25 or less. b. Smoke developed index: 450 or less. Specifier: Retain "Intermediate Scale Multistory Fire Test" Paragraph when required by authorities having jurisdiction. 2. Intermediate Scale Multistory Fire Test: Representative mockup tested per NFPA 285. Specifier: Retain "Fire Performance of Insulated Wall" subparagraph when required by Owner's insurer; retain requirement for 26 ga. panel faces in Part 2. 3. Fire Performance of Insulated Wall: Approved as a Class 1 wall panel per ANSI/FM 4880. 1.5 QUALITY ASSURANCE Specifier: If project procurement procedures allow retaining manufacturer and product name in Part 2, retain paragraph and subparagraphs below to establish project procedures for evaluation of substitution requests. A. Manufacturer Qualifications: Manufacturer listed in this Section or approved for Project with a minimum 5 years of experience in manufacture of similar products in successful use in similar applications. Page 5 of 12

1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time period allowed for substitution review: a. Product data, including certified independent test data indicating compliance with requirements. b. Samples of each component. c. Sample submittal from similar project. d. Project references: Minimum of 5 installations not less than 5 years old, with owner contact information. e. Sample warranty. 2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements. 3. Approved manufacturers must meet separate requirements of Submittals Article. B. Installer Qualifications: Experienced Installer with minimum of 5 successful completed projects of similar materials and scope and employing workers trained by manufacturer to install products of this section. Installer must provide proof of training at the time of submittal. See section 1.11 for further verification and warranty requirements. Specifier: Retain "Buy American Act Certification" when required by project; coordinate with requirements in Submittals article. C. Buy American Act Certification: Comply with provisions of the Buy American Act 41 U.S.C 10a 10d. 1.6 ADMINISTRATIVE REQUIREMENTS A. Coordination: Coordinate the installation of metal wall backup panel system structural support and exterior wall cladding panels. B. Pre-installation Meeting: Conduct pre-installation meeting at site attended by Owner, Architect, manufacturer's technical representative, and other trade contractors. 1. Coordinate building framing in relation to metal wall backup panels. 2. Coordinate window, door, and other openings and penetrations of metal wall backup panels. 1.7 ACTION SUBMITTALS A. Product Data: Manufacturer s data sheets for metal wall backup panels and accessories. B. Shop Drawings: Prepared by manufacturer or manufacturer's authorized dealer. Installation drawings for metal wall backup panels, flashing, accessories, and anchorage systems must indicate completely dimensioned structural frame and erection layouts, openings in the wall, special framing details, and construction details at corners, building intersections and flashing, location and type of mastic and metal filler strips. 1. Indicate coordination dimensions related to structural support system elements provided by others. 2. Include structural data indicating compliance with performance requirements. Specifier: Retain and edit below to comply with Project requirements for sustainable design requirements. Page 6 of 12

1.8 INFORMATIONAL SUBMITTALS A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency. B. Qualification Information: For Installer firm, Installer s field supervisor. Specifier: Retain "Buy American Act Certification" paragraph when required by project; coordinate with requirements in Submittals article. C. Buy American Act certification. 1.9 CLOSEOUT SUBMITTALS A. Maintenance data. 1.10 DELIVERY, STORAGE, AND HANDLING A. Protect metal wall backup panels during shipping, handling, and storage to prevent staining, denting, or other visible damage. Deliver, unload, store, and erect metal wall backup panels and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations. Protect from exposure to sunlight. 1.11 WARRANTY Specifier: Warranty terms below are available from CENTRIA. Verify that other allowable manufacturers furnish warranty meeting requirements. A. Special Manufacturer s Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace metal wall backup panel assemblies that fail in materials and workmanship within [2] years from the date of substantial completion. B. Weathertight Wall Warranty: Provide manufacturer s standard limited weathertight wall warranty in which manufacturer will warrant against leakage under the specified project design criteria or normal weather and atmospheric conditions for a period of ten years based on a review of final installation drawings and verification of installation by a manufacturer trained installer. Project installation inspection is at the sole discretion of the manufacturer. PART 2 - PRODUCTS 2.1 SYSTEM DESCRIPTION A. Insulated-Core Metal Wall Backup Panel System: Metal wall backup panel installation consisting of foamed-insulation-core metal-skinned wall panels and accessories, attached to metal framing with specified clips or rails, serving as combined thermal, air, and moisture barrier and support for [metal wall panel rainscreen cladding] [brick veneer] [terra cotta veneer] specified in another section. Specifier: If project procurement procedures allow retaining manufacturer and product name, retain paragraph and subparagraphs below and modify as required. Page 7 of 12

2.2 MANUFACTURERS A. Basis of Design: CENTRIA, MetalWrap. Provide basis of design product [or comparable products of other manufacturer approved by Architect in accordance with Instructions to Bidders and Division 01 General Requirements]. 1. CENTRIA Architectural Systems; Moon Township PA 15108-2944; (800)759-7474; (412)299-8000; info@centria.com; www.centria.com. B. Single Source: Obtain metal wall backup panels and exterior cladding panels specified in Division 07 Section "Metal Wall Panels" through one source from a single approved manufacturer. Specifier: CENTRIA MetalWrap Insulated Composite Backup Panels are available in 12 foot (3658 mm) and 20 foot (6096 mm) lengths. MetalWrap Integrated with pressure equalized joinery comes in two widths, in two thicknesses and is installed horizontally over steel studs up to 24 OC. MetalWrap Long Span comes in two widths and three thicknesses and can be installed vertically or horizontally for applications over steel girts up to 6 OC. Panels are configured and shipped to accommodate application for backup panels for vertical or horizontal cladding or as masonry veneer backup. 2.3 METAL WALL BACKUP PANELS A. Insulated Composite Backup Panels: Foamed-insulation-core metal-skinned panels with interlocking side joinery and butted end joints. Fabricate in factory with metal facings bonded to foamed-in-place core. Fabricate interior metal face with planking ribs. Form interlocking joinery to accept concealed fasteners for attachment to supports. 1. Basis of Design Product: CENTRIA, MetalWrap Insulated Composite Backup Panel. Specifier: Retain one "Panel Faces" paragraph below as required for project. 29-ga panel is typical for MetalWrap Integrated Systems; 22-ga panel is required for MetalWrap Long Span panel applications and for horizontal applications where compliance with FM 4880 Class 1 fire rating is required. B. MetalWrap Integrated Panel Faces: [(0.014-inch/29-ga. (0.360-mm)] thick aluminum-zinc alloy coated steel sheet: ASTM A 792/A 792M, Class AZ50 (Class AZM150) coating designation; structural quality, with smooth surface. [optional: (0.019-inch/26-ga. (0.480-mm), (0.025- inch/24-ga. (0.635-mm), (0.031-inch/22-ga. (0.794-mm)] C. MetalWrap Long Span Panel Faces: [(0.031-inch/22-ga. (0.794-mm)] thick metallic-coated steel sheet: ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality, with smooth surface. [optional: (0.0375-inch/20-ga. (0.953-mm)] Specifier: First option in "Panel Face Finish" paragraph is standard; second option is available for louver blank-off panels. D. Panel Face Finish: [0.2-mil (0.051-mm) thick primer coat and 0.2-mil (0.051-mm) thick primer coat on interior face.] [Add for louver blank-off panels: 0.8-mil (0.203-mm) thick black silicon polyester color coat on exterior face]. E. Panel Core: Foamed-in-place modified polyisocyanurate, closed-cell, CFC and HCFC free, with minimum density of 2.4 lb./cu. ft. (39 kg/cu. m) and minimum compressive strength of 15 lb./sq. in. (103 kpa). F. Panel Sealant/Vapor Seal: Factory-applied non-curing butyl. Page 8 of 12

Specifier: Retain "Integrated Horizontal Panel" or "Long Span Vertical [or Horizontal] Panel" paragraph below as required for project. Retain one of options based upon project thermal performance requirements. G. Metal Wall Integrated Hoizontal Backup Panel Thickness and Thermal Resistance: [2 inches (51 mm); R-14, U-.074] [3 inches (76 mm); R-21, U-.047]. Specifier: Select one of two options based upon project thermal performance requirements. H. Metal Wall Long Span Vertical [or Horizontal] Backup Panel Thickness and Thermal Resistance: [2 inches (51 mm); R-14, U-.074] [2.75 inches (69 mm); R-20, U-.049] [4 inches (101 mm); R-27, U-.039]. Specifier: Retain second option in "Panel Width" subparagraph when required to align ties in panel joints with masonry course spacing or for Long Span over steel girts. I. Panel Width: Integrated [36 inches (914 mm)] [32 inches (813 mm)]. Long Span [36 inches (914 mm)] [30 inches (762 mm)] J. Panel Configuration: Provide metal wall backup panels configured for the following application system: Specifier: Retain one or more of the following backup panel configurations as required for project. System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 1 System with MR-100 Integral Attachment System utilizing vertical subgirt. 1. Horizontal metal wall backup panels with integral pre-punched thermally isolated Z-girt (MR100) attachment system configured to serve as attachment points for manufacturerfurnished vertical sub-girts to receive horizontal cladding. System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 2 System with MR-100 Integral Attachment System 2. Horizontal metal wall backup panels with integral pre-punched thermally isolated Z-girt (MR100) attachment system configured to serve as attachment points to receive the direct attachment of vertical cladding. System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 3 System with MR-300 Integral Attachment System. 3. Horizontal metal wall backup panels with integral pre-punched thermally isolated hat channel (MR300) sub-girt attachment system configured to serve for the direct attachment of vertical cladding. System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 4 System with MR-300 Integral Attachment System utilizing vertical sub-girts. 4. Horizontal metal wall backup panels with integral pre-punched thermally isolated hat channel (MR300) sub-girt attachment system configured to serve for the attachment of manufacturer-furnished vertical sub-girts to receive horizontal cladding System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 5 System. Utilize CENTRIA panel clips for the attachment of vertical sub-girts. System requires min. 16 ga. steel stud framing. Page 9 of 12

5. Horizontal metal wall backup panel with manufacturer-furnished panel clip attachment to serve as attachment points for vertical subgirts to receive horizontal cladding. System in subparagraph below corresponds to CENTRIA MetalWrap Integrated Type 6 System utilizing Hohmann and Barnard Joint Anchors and Surface Mount Anchors. 6. Horizontal metal wall backup panel for masonry veneer, with manufacturer-furnished Hohmann and Barnard Joint Anchors and Surface Mount Anchors in panel joints and attached at panel midpoints. System in subparagraph below utilizes CENTRIA MetalWrap Long Span Type 7 System oriented vertically using panel attachment clips. Horizontal manufacturer supplied sub-girts attached to panel joinery. System may be utilized for wall construction framed with horizontal purlins. 7. Vertical installation metal wall backup panel with manufacturer-furnished panel attachment clips and horizontal sub-girts attached to panel joinery to receive vertical cladding. System in subparagraph below utilizes CENTRIA MetalWrap Long Span Type 8 System oriented vertically using panel attachment clips. System may be utilized for wall construction framed with horizontal purlins. 8. Vertical installation metal wall backup panel with manufacturer-furnished panel attachment clips and vertical sub-girts attached to panel joinery to receive horizontal cladding. System in subparagraph below utilizes CENTRIA MetalWrap Long Span Type 9 System oriented vertically using panel attachment clips. Horizontal cladding with standoff clips may be attached to panel joinery. System may be utilized for wall construction framed with horizontal purlins. 9. Vertical installation metal wall backup panel with manufacturer-furnished panel attachment clips and horizontal Concept series or Cascade series with special stand-off clips fastened through backup panel joinery. System in subparagraph below utilizes CENTRIA MetalWrap Long Span Type 10 System oriented horizontally using panel attachment clips configured to accept vertical sub-girts. System may be utilized for wall construction framed with vertical purlins. 10. Horizontal installation metal wall backup panel with manufacturer-furnished panel attachment clips and vertical sub-girts attached to panel joinery to receive horizontal cladding. 2.4 METAL WALL BACKUP PANEL ACCESSORIES A. Sub-girts: Metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality, 0.054-inch/16-gage (1.37-mm) thick. B. Panel Attachment Clips: Metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z275) coating designation, of thickness indicated, configured to serve as attachment points for secondary metal framing where indicated, manufacturer-furnished. C. Self-Adhering Sheet Flashing Tape: Minimum 25-mil (0.64-mm) modified bituminous sheet, recommended by panel manufacturer for application. D. Joint Sealants: 1. Concealed: Non-skinning butyl sealant, AAMA 809.2. Page 10 of 12

2. Exposed: Elastomeric silicone sealant, ASTM C 920, as recommended by panel manufacturer. E. Fasteners: Corrosion-resistant, self-tapping and self-drilling screws, bolts, nuts, and other fasteners as recommended by panel manufacturer for application. 1. Size fasteners to prevent penetration of interior panel facing. 2.5 FABRICATION A. General: Fabricate metal wall backup panels at the factory, using manufacturer's standard procedures and processes identical to tested units and as necessary to meet performance requirements. 1. Fabricate metal wall backup panels with joints between panels designed to form weathertight seals. 2. Factory form metal wall backup panels in a continuous process with no glues or adhesives between dissimilar materials. Trim and square edges of sheets with no displacement of face sheets or protrusion of core material. PART 3 - EXECUTION 3.1 EXAMNINATION A. Examine building structure with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation. B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer. 1. Maximum deviations acceptable: a. 3/8 inch (9.5 mm) in any 20-foot (6.1 m) length vertically or horizontally from the framing face plane. b. 3/4 inch (19 mm) maximum deviation from the framing face plane on any building elevation. C. Framing: Inspect framing that will support metal wall backup panel system to determine if support components are installed as indicated on approved shop drawings. D. Advise G.C, in writing, of out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation. E. Correct out of tolerance work and other deficient conditions prior to proceeding with insulated composite backup panel installation. 3.2 METAL WALL BACKUP PANEL SYSTEM INSTALLATION A. General: Install metal wall backup panel system in accordance with approved shop drawings and manufacture's recommendations. Page 11 of 12

B. Installation: Attach backup panels to supports at each panel connection point indicated on approved shop drawings. 1. Install with drain plane of panel facing weather side of installation. 2. Fasten insulated metal wall backup panels to building framing with [continuous integral attachment sub-girts] or [manufacturer provided panel attachment clips and anchors] provided by manufacturer utilizing recommended fasteners. 3. Horizontal Joinery: Working from base to top of metal wall backup panel system installation, engage upper panel over lower panel to form a weather tight joint oriented to allow gravity drainage. 4. Vertical Joinery: 3.3 ERECTION TOLERANCES a. Install vertical butt joints tight with no gap, set against continuous supports. b. Set panel ends in continuous bead of non-curing butyl sealant as indicated in manufacturer's installation details. c. Seal butt joints between adjacent panels with a continuous strip of self-adhering flashing at bottom row of panels and where additionally recommended by manufacturer or architect. A. Installation Tolerances: Align metal wall backup panel system within installed tolerance of 1/4 inch in 20 feet (6 mm in 6.1 m), noncumulative, on level and plumb and location lines as indicated and within 1/8 inch (3 mm) offset of adjoining faces and of alignment of matching profiles. END OF SECTION Page 12 of 12