SL35 Introduction. NanaWall SL35 The Standard Aluminum Framed Folding System

Similar documents
Guide Specifications - Section SL35. NanaWall SL35, Aluminum Framed Folding System PART 1 - GENERAL

SL45 Guide Specifications - Section

Guide Specifications - Section : NanaWall WD65 - Wood Framed Folding/Paired Panel System PART 1 GENERAL

WA67 Guide Specifications - Section

HSW45 Introduction. NanaWall HSW45 Standard Aluminum Framed Single Track Sliding System

The Structurally Glazed Folding System with Exterior All Glass Aesthetic

The Aluminum Framed Monumental Folding/Paired Panel System

SL60 Introduction. NanaWall SL60 The Standard Thermally Broken Aluminum Framed Folding System

NanaWall Matching Windows and Doors Table of Contents

WD65 Guide Specifications - Section

SL73 - Aluminum Framed Thermally Broken Hurricane Approved Folding System

WD66 Guide Specifications - Section

Guide Specifications - Section HSW66

SL70 The Monumental Thermally Broken Aluminum Framed Folding System

SL70 Introduction. NanaWall SL70 The Monumental Thermally Broken Aluminum Framed Folding System

WD66 The Standard Wood Framed Folding System

WD65 Wood Framed Folding/Paired Panel System for Special Applications

Guide Specifications- Section

WD66 The Standard Wood Framed Folding System

SL25 NanaGlass Introduction

Guide Specifications- Section

HSW60 Introduction. NanaWall HSW60 The Thermally Broken Aluminum Framed Single Track Sliding System

VSW65 BeyondLiftSlide / SwingSlide Introduction

GUIDE SPECIFICATIONS - SECTION

SECTION FOLDING GLASS PARTITIONS

SECTION FOLDING GLASS PARTITIONS

SECTION FOLDING GLASS STOREFRONTS SECTION FOLDING GLASS DOORS

NanaWall HSW60 - Thermally Broken Aluminum Framed Single Track Sliding System

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

PRODUCT SPECIFICATION THE 9500 SERIES FAMILY - SERIES 9502 / 9503 THERMALLY BROKEN ALUMINUM OUTSWING BALCONY DOOR

SECTION SLIDING GLASS PARTITIONS

PRODUCT SPECIFICATION SERIES 4500T THERMALLY BROKEN ALUMINUM SLIDING BALCONY DOOR

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

SECTION ALL GLASS ACOUSTIC SLIDING PARTITION

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

SECTION K. Section Millwork: Wood trim other than furnished by door and frame manufacturer

SECTION ALUMINUM WINDOWS

SLIDING SECTION 8 SPECIFICATIONS

SECTION PREHUNG WOOD DOORS. Display hidden notes to specifier. (Don't know how? Click Here)

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

SECTION ALUMINUM STORM WINDOWS

SECTION SLIDING GLASS STOREFRONTS SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION ALL GLASS CENTER PIVOT PARTITIONS

SECTION FOLDING GLASS STOREFRONTS SECTION FOLDING GLASS DOORS

FL550 21/2 x5 GUIDE SPECIFICATION. Impact-Resistant Storefront

SECTION ALL ULTREX DOUBLE HUNG WINDOW

2000/2100/2200 Series Heavy Commercial Sliding Patio Doors

PRODUCT SPECIFICATION SERIES 5000T PUNCHED WINDOW THERMALLY BROKEN ALUMINUM CASEMENT/AWNING/ FIXED WINDOW

SECTION VINYL (PVC) WINDOWS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

SECTION SLIDING ALUMINUM-FRAMED GLASS DOORS Panda Windows and Doors, Thermally Broken Multi-Slide Door Systems

A. Section Cast-In-Place Concrete: Openings in cast-in-place concrete.

Series B450 Guide Specification

SECTION WOOD FRAMED FOLDING GLASS PARTITIONS

Section A2 Table of Contents ALL GLASS ENTRANCES

Impact-Resistant Entrances Series

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

SECTION ALUMINUM WINDOWS

SECTION SECTIONAL OVERHEAD DOORS

SECTION VINYL WINDOWS AND DOORS. 2.2 Slider Windows Classic Series (Standard sizes) and Thermo-Fit Series (Custom sizes)

PRODUCT SPECIFICATION UNITIZED CURTAIN WALL THERMALLY BROKEN ALUMINUM AWNING/ FIXED WINDOW

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Specification Section Storefront Systems has been revised. Omit previously issued Storefront section.

PrivaSEE All Glass Single Track Sliding System for Acoustical Separation

SPECIFICATION - SECTION (10650) OPERABLE PARTITIONS

FL550T 21/2 x5. GUIDE SPECIFICATION Series FL550T Thermal (21/2 x 5 ) Impact-Resistant Storefront. Thermal Impact-Resistant Storefront

MODERNFOLD GWS 100SR-G MOVEABLE GLASS WALLS

SPECIFICATION GUIDE SERIES 800 HEAVY PICTURE WINDOW

SECTION FOLDING ALUMINUM FRAMED WALL SYSTEM

1 3 4 Tie Rod Aluminum Swing Entrance Doors

Series 3500 Thermal Series 3900 Fixed Thermal Architectural Grade Horizontal Sliding Window

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

Theut Company,LLC Theut Company, LLC

Aluminum Storefront Systems SERIES 200, 300 and 500 DOORS GUIDE SPECIFICATIONS

SECTION ALUMINUM STORM WINDOWS

SECTION U.S. ALUMINUM SERIES BAL-350 HURRICANE RESISTANT BALCONY/TERRACE DOOR

NanaScreen Table of Contents

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

PW251 21/2 x7 GUIDE SPECIFICATION. Curtain Wall

CTB Commercial Aluminum Window

PRODUCT SPECIFICATION SERIES 9000 WINDOW WALL THERMALLY BROKEN ALUMINUM CASEMENT / AWNING / FIXED WINDOW

TEST REPORT. Report No.: G Rendered to: C.R. LAURENCE CO., INC. Vernon, California

Series 510-I Thermal Heavy Commercial Projected Window

SECTION ACCORDION FOLDING PARTITIONS

TMW 450 TECHNICAL MANUAL

TMS 152 / 152T / 152XT TECHNICAL MANUAL

ACOUSTI-CLEAR AUTOMATIC SERIES TECHNICAL DATA

Series 660 Single Hung * Series 670 Double Hung Series 6600 Fixed ** Heavy Commercial Hung Thermal Window

TMS 114 XT TECHNICAL MANUAL

SECTION SERIES 200 DOUBLE-HUNG VINYL WINDOWS

3 7 8 Heavy Commercial Hung Thermal Window

SOTA THERMO 3 SERIES SPECIFICATION FOR PREGLAZED & UNITIZED THERMO 3 CURTAINWALL SYSTEM

Unitised Curtain Wall Beaded

Sliding Door Systems

SECTION / METAL FRAMED SKYLIGHTS

SECTION ALUMINUM ENTRANCES AND STOREFRONTS. A. Section Includes: Aluminum doors and window wall frames.

MARLIN WINDOWS, INC 3500 HC SERIES 3 3 8" SLIDING WINDOW PAGE 1

Transcription:

SL35 Introduction NanaWall SL35 The Standard Aluminum Framed Folding System The SL35 is an aluminum folding panel system designed to provide a moving glass wall for openings as wide as 39. It is a top-hung system mostly appropriate for residential applications. For benefits of all NanaWall systems, see the General Introduction section. For features common to aluminum folding systems, see the Aluminum Folding Systems Introduction. Weather Resistant The system is engineered to be weather resistant and provide high structural performance. An inward-opening unit with raised sill with panel size of about 2 8 x 7 0 tested to AAMA HGD-R20 (see the Testing section). Especially for High Rises: Easy Cleaning Feature For balcony applications, there is an easy hinge removal option, facilitating glass cleaning from the inside. Additional Stacking Configurations Angled units of 90 are possible. To see these operable wall concepts in action, please visit www.nanawall.com and click on the Animations link. SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 1

SL35 Technical Description Technical Description General Description The SL35 is an aluminum folding panel system designed to provide an opening glass wall or storefront for openings as wide as 39 (see Maximum Size Chart). The system is available in various configurations utilizing one to twelve panels (see elevation drawings). The option exists for a swing entry/exit panel; note, however, the panel size constraints with a swing panel not hinged to a side jamb. Units can be either inward or outward opening (see details in section drawings). Frame and Panels The nominal frame and panel thickness is 1 3/8 (35 mm) extruded aluminum (See section drawings). In addition to the choices from the NanaWall Powder Coating Finish Chart, the full range of RAL high gloss and matte powder coatings are available. Anodized finished are also available. Panel stiles and rails, as well as frame corners, are connected by special cast-alloy corner fittings that incorporate hinge components. Finish on corner connectors will be closest powder coat match to the finish on the frame and panels. Panels are pre-assembled, and all pins and screws necessary to assemble the frame are provided. Besides the more weather resistant raised sill, various flush sills and Low Profile Saddle Sill (shown in section drawings) are available as an option. Glazing Units can be supplied either glazed with 3/16 (5 mm) single tempered or laminated, 11/16 (18 mm) clear insulating tempered or insulating Low-E tempered glass or other high performing safety glass on request. See Glazing in the General Introduction for other glass thickness possible. Weatherstripping All weather stripping, consisting of EPDM or brush seals, is provided for sealing between panels and between panels and frames (see section drawings). Sliding/Folding Hardware Attached to the upper corner of a panel (see section drawings) is a patented, load-bearing, upper-running carriage for sliding and folding each pair of panels; attached to the lower corner is a lower-running carriage as a guide. The double pair, twin tandem, upper-running carriage is constructed to ensure even pressure distribution on all four rollers. Rollers have sealed bearings and are coated with toughened Polyamide to ensure quiet running and optimal resistance to extreme temperature. Corner connector with hinges at the corners of each panel connect panels to each other and connect panels to the side jamb. Locking Hardware and Handle Options For each pair of folding panels (except for the pair to be opened first in a unit with no swing panels) provided is two point locking hardware consisting of top and bottom Polyamide capped locking bolts operated by a 180 turn of a flat handle on the inside only. For a unit with a swing panel, on the primary swing panel, there is the following additional hardware option: Three point locking hardware consisting of top and bottom Polyamide capped locking rods and a horizontal bolt operated by a 180 turn of L-shaped handles located on both the inside and outside. Lockable with a lockset. Turn of key or thumb turn operates lock. For a unit with no swing panel, on the folding pair to be opened fi rst, provided is two point locking hardware consisting of top and bottom Polyamide capped locking rods operated by a 180 º turn on the inside of a L-shaped handle for an inward opening unit and a fl at handle for an outward opening unit. In both cases, there will be a fl at handle on the outside. Lockable with a lockset. Turn of key or thumb turn operates lock. Please note that for an outward opening unit, locking from the inside will need to be with a key that may not meet egress requirements. For a unit where locking/handles on the inside only is desired, like in window applications, on all swing panels or pair of folding panels to be opened fi rst, provided is two point locking with a fl at handle on the inside only. Handle finish schemes: Standard Stainless steel fl at and L shaped handles in brushed satin or black titanium fi nish. Optional Flat handles closest powdercoat match to panel aluminum fi nish and nylon L shaped handles in dark brown, gray or white fi nish. 2 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

SL35 Testing Results - Performance of the SL35 NanaWall RAISED SILL Type of Test Inward Opening Units Outward Opening Units * Air Infiltration: @ 1.57 psf (75 Pa): 0.15 ASTM E-283, cfm/m 2 @ 6.24 psf (300 Pa): 0.32 @ 1.57 psf (75 Pa): 0.11 @ 6.24 psf (300 Pa): 0.24 * Water Penetration: ASTM E-547 No uncontrolled water entry @ 3 psf (140 Pa) No uncontrolled water entry @ 5.25 psf (250 Pa) * Structural Load Deflection ASTM E-330: pass See design windload charts for other sized panels. Note that the structural test pressures were 50% higher than the design pressures. Standard Unit Design Pressure Positive @ 35 psf (1670 Pa) Design Pressure Negative @ 35 psf (1670 Pa) Unit with reinforced locking Design Pressure Positive @ 40 psf (1900 Pa) Design Pressure Negative @ 40 psf (1900 Pa) Standard Unit Design Pressure Positive @ 35 psf (1670 Pa) Design Pressure Negative @ 35 psf (1670 Pa) Unit with reinforced locking Design Pressure Positive @ 40 psf (1900 Pa) Design Pressure Negative @ 40 psf (1900 Pa) Thermal Performance: Summary of NFRC U-Factor Computer Simulation Report prepared by Architectural Testing Not NFRC Certified Clear Low E (air filled) Low E (argon filled) Single Glazing With 18 mm (.70 ) Thick Insulated Glass: U-Factor.69.58.55 1.16 With 18 mm (.70 ) Thick Insulated Glass: U-Factor.69.58.55 1.16 * Forced Entry Resistance In accordance with AAMA-1303.5 and CAWM 300-96 requirements. * Excerpts of results of a 8 5 W x 7 4 H three panel units with a raised sill tested by Architectural Testing, Inc., Fresno, CA, an independent testing laboratory in March 1997 and February 2000. These units tested to meet AAMA HGD-H20. LOW PROFILE SADDLE SILL AND FLUSH SILL Type of Test Inward Opening Units Outward Opening Units Structural Load Deflection ASTM E-330: pass Per engineering letter based on raised sill testing. See design windload charts for other sized panels. Note that the structural test pressures were 50% higher than the design pressures. Thermal Performance: Summary of NFRC U-Factor Computer Simulation Report prepared by Architectural Testing Not NFRC Certified Clear Low E (air filled) Low E (argon filled) Single Glazing Standard Unit Design Pressure Positive @ 35 psf (1670 Pa) Design Pressure Negative @ 35 psf (1670 Pa) Unit with reinforced locking Design Pressure Positive @ 40 psf (1900 Pa) Design Pressure Negative @ 40 psf (1900 Pa) With.70 (18 mm) Thick Insulated Glass: U-Factor.69.58.55 1.16 Standard Unit Design Pressure Positive @ 35 psf (1670 Pa) Design Pressure Negative @ 35 psf (1670 Pa) Unit with reinforced locking Design Pressure Positive @ 40 psf (1900 Pa) Design Pressure Negative @ 40 psf (1900 Pa) With.70 (18 mm) Thick Insulated Glass: U-Factor.69.58.55 1.16 * Forced Entry Resistance In accordance with AAMA-1303.5 and CAWM 300-96 requirements. SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 3

SL35 Relationship of Frame, Panel and Glass Daylight Opening Sizes Dimensions in millimeters unless noted. Calculation applies to the standard stiles and rails. Glass dimensions of all panels in a unit are equal. Nominal Panel Height (PH) is defined as Glass Daylight Opening Height + 98 = (3 7/8 ). Nominal Panel Width (PW) is defined as Glass Daylight Opening Width + 98 = (3 7/8 ). Panel Height is as seen from the inside on an inward opening unit and is as seen from the outside on an outward opening unit. Please note that with the overlap of the head jamb and the sill with the panel, the Clear Opening Height will not be the same as the Panel Height. See Cross-Section Details of both stiles of each panel to determine actual Panel Width. With astragals, overlapping, etc., the actual Panel Width not only varies with position of panel in a configuration, but the inside and outside surface widths of each stile may be different. For each configuration, the Frame Width (FW) is the sum of the nominal Panel Width (PW) x the number of panels + a number (N) which is the sum of the side jamb dimensions and dimensions of space between panels in excess of the nominal Panel Width as shown in the Cross-Section Details. Frame Height (FH) SL35 System Raised Sill: Frame Height = Panel Height + 94 (3 11/16 ) = Clear Opening Height + 120 (4 3/4 ) Flush Sill: Frame Height = Panel Height + 94 (3 11/16 ) = Clear Opening Height + 100 (3 15/16 ) Low Profile Saddle Sill: Frame Height = Panel Height + 104 (4 1/8 ) = Clear Opening Height + 110 (4 5/16 ) Frame Widths for Different Configurations with Majority of Panels Folding to Right (and their Mirror Image Configurations with Majority of Panels Folding to Left). See Maximum Size Charts for size limits. These numbers can be used as a guideline only. Contact NanaWall for the exact calculations for a particular unit. Please note that widths for units with unhinged panels or angle turns will be different. Model 1R Frame Width = 1 x Panel Width + 112 = 1 x Panel Width + 4 7/16 Model 1L1R Frame Width = 2 x Panel Width + 114 = 2 x Panel Width + 4 1/2 Model 2R Frame Width = 2 x Panel Width + 145 = 2 x Panel Width + 5 11/16 Model 3R Frame Width = 3 x Panel Width + 116 = 3 x Panel Width + 4 9/16 Model 1L2R Frame Width = 3 x Panel Width + 147 = 3 x Panel Width + 5 13/16 Model 4R Frame Width = 4 x Panel Width + 149 = 4 x Panel Width + 5 7/8 Model 1L3R Frame Width = 4 x Panel Width + 118 = 4 x Panel Width + 4 5/8 Model 2L2R Frame Width = 4 x Panel Width + 180 = 4 x Panel Width + 7 1/16 Model 5R Frame Width = 5 x Panel Width + 120 = 5 x Panel Width + 4 3/4 Model 1L4R, Model 2L3R Frame Width = 5 x Panel Width + 151 = 5 x Panel Width + 5 15/16 Model 3L3R, Model 1L5R Frame Width = 6 x Panel Width + 122 = 6 x Panel Width + 4 13/16 Model 2L4R Frame Width = 6 x Panel Width + 184 = 6 x Panel Width + 7 1/4 Model 6R Frame Width = 6 x Panel Width + 153 = 6 x Panel Width + 6 Model 3L4R, Model 2L5R, Model 1L6R Frame Width = 7 x Panel Width + 155 = 7 x Panel Width + 6 1/8 Model 4L4R, Model 2L6R Frame Width = 8 x Panel Width + 188 = 8 x Panel Width + 7 3/8 Model 3L5R Frame Width = 8 x Panel Width + 126 = 8 x Panel Width+ 4 15/16 Model 4L5R, Model 3L6R Frame Width = 9 x Panel Width + 159 = 9 x Panel Width + 6 1/4 Model 5L5R Frame Width = 10 x Panel Width + 130 = 10 x Panel Width +5 1/8 Model 4L6R Frame Width = 10 x Panel Width + 192 = 10 x Panel Width + 7 9/16 Model 5L6R Frame Width = 11 x Panel Width + 163 = 11 x Panel Width + 6 7/16 Model 6L6R Frame Width = 12 x Panel Width+ 196 = 12 x Panel Width + 7 11/16 4 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

SL35 Maximum Size Chart (with different number of panels) Solid dark line on chart indicates maximum frame height possible for a given maximum frame NOTE: English dimensions are approximate. Dimensions in parenthesis are in millimeters width with double glazing. Broken line on chart indicates maximum Frame Height of Unit 9 2 (2800) 8 10 (2700) 8 6 (2600) 8 2 (2500) 7 10 ((2400) 7 6 (2300) A - Double Glazed B - Double Glazed A - Single Glazed B - Single Glazed frame height possible for a given maximum frame width with single glazing. A horizontal mullion is needed for a unit with a frame height of more than 8 2 Any custom size is possible up to the maximum size shown. A. Single or Double Glazed either for configurations with folding panels only or for configurations with folding panels and a swing door hinged to a side jamb- includes Models 1L, 1R, 1L1R, 2R, 1L2R, 4R, 1L6R, 2L2R, 1L4R, 2L4R, 6R, 2L6R, 4L4R, 4L6R, 2L, 2L1R, 4L, 4L1R, 4L2R, 6L, 6L1R, 6L2R, 6L4R, 6L6R, 6L1R 7 2 (2200) 6 10 (2100) and below Frame Width of Unit B. Single or Double Glazed for all configurations. If larger sized panels are needed, please consider the SL45 system. Generally, the minimum width of each panel is 1 11 (600 mm). 1 2 3 4 5 2 3 2 7 2 11 3 3 (700) (800) (700) (1000) 4 7 5 3 5 10 6 6 (1400) (1600) (1800) (2000) 6 10 7 10 8 10 9 10 (2100) (2400) (2700) (3000) 9 2 10 6 11 9 13 1 (2800) (3200) (3600) (4000) 11 5 13 1 14 9 16 4 (3500) (4000) (4500) (5000) The maximum size limits for double glazing are based on the maximum weight of a panel being 5.5 lbs/sq ft (this weight is based on using standard insulated glass with a net glass thickness of 5/16 (8 mm) or thickness of 5/32 (4 mm) for each glass pane). The maximum size limits for single glazing are based on a glass thickness of 3/16 (5mm). For other net glass thickness, this maximum size limit chart will not apply. Number of Panels in Unit 6 7 8 9 10 13 10 15 8 17 8 19 8 (4200) (4800) (5400) (6000) 16 18 4 20 7 22 10 (4900) (5600) (6300) (7000) 18 4 20 11 23 6 26 1 (5600) (6400) (7200) (8000) 20 7 23 6 26 5 29 4 (6300) (7200) (8100) (9000) 22 10 26 1 29 4 32 9 (7000) (8000) (9000) (10000) 11 25 1 28 8 32 5 36 1 * (7700) (8800) (9900) (11000) 12 27 4 31 5 35 5 39 4 * (8400) (9600) (10800) (12000) SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 5

SL35 Inward Opening Section Details All Cross Sectional Views Are Half Size Detail 1.0 Head Jamb Detail 2.0 Raised Sill Frame Height Detail 22.0 Low Profile Saddle Sill (For resistance against wind driven rain, drain connections by others necessary. No rating for air infiltration.) Detail 26.0 Flush Sill (No rating against wind driven rain or for air infiltration.) FFH Surface Mounted Interior Sill See www.nanawall.com for details 6 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Inward Opening Section Details Detail 3.0 Panel hinged at right side jamb Detail 3R.0 Panel hinged at left side jamb Detail 7R.0 Left folding panel with locking Detail 7.0 Right folding panel with locking Detail 7RC.0 Left folding panels with running carriage set Detail 7C.0 Right folding panel with running carriage set SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 7

SL35 Inward Opening Section Details All Cross Sectional Views Are Half Size Detail 8.0 Two swing panels with locking: left panel opening first Detail 8R.0 Two swing panels with locking: right panel opening first Detail 4.0 Swing panel with locking at left side jamb 8 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Inward Opening Section Details Detail 4R.0 Swing panel with locking at right side jamb Detail 5.0 Panel with running carriage set meeting left side jamb Detail 5R.0 Panel with running carriage set meeting right side jamb SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 9

SL35 Inward Opening Section Details All Cross Sectional Views Are Half Size Detail 9.0 Meeting of panels folding to opposite sides (no swing panel). Running carriage sets on both panels (limited in weather resistance) Detail 9R.0 Meeting of panels folding to opposite sides (no swing panel). Running carriage sets on both panels (limited in weather resistance) Detail 10.0 Meeting of swing panel with locking on left and folding panel with running carriage set on right Detail 10R.0 Meeting of swing panel with locking on right and folding panel with running carriage set on left 10 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Outward Opening Section Details Detail 1.1 Head Jamb Detail 2.1 Raised Sill Frame Height Detail 22.1 Low Profile Saddle Sill (For resistance against wind driven rain, drain connections by others necessary. No rating for air infiltration.) Detail 26.1 Flush Sill (No rating against wind driven rain or for air infiltration.) FFH SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 11

SL35 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 3.1 Panel hinged at right side jamb Detail 3R.1 Panel hinged at left side jamb Detail 7R.1 Left folding panel with locking Detail 7.1 Right folding panel with locking Detail 7RC.1 Left folding panels with running carriage set Detail 7C.1 Right folding panel with running carriage set 12 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Outward Opening Section Details Detail 8.1 Two swing panels with locking: left panel opening first Detail 8R.1 Two swing panels with locking: right panel opening first Detail 4.1 Swing panel with locking at left side jamb SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 13

SL35 Outward Opening Section Details All Cross Sectional Views Are Half Size Detail 4R.1 Swing panel with locking at right side jamb Detail 5.1 Panel with running carriage set meeting left side jamb Detail 5R.1 Panel with running carriage set meeting right side jamb 14 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Outward Opening Section Details Detail 9.1 Meeting Panels Folding to Opposite Sides (No Swing Panel) Running Carriage Sets on Both Sides (Limited in weather resistance) Detail 9R.1 Meeting Panels Folding to Opposite Sides (No Swing Panel) Running Carriage Sets on Both Sides (Limited in weather resistance) Detail 10.1 Meeting of Swing Panel with Locking on Left and Folding Panel with Running Carriage Set on Right Detail 10R.1 Meeting of Swing Panel with Locking on Right and Folding Panel with Running Carriage Set on Left SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 15

SL35 Inward Opening Suggested Typical Installation All Cross Sectional Views Are Half Size See Installation Notes on Next Page Panel Hinged At Right Side Jamb Head Jamb Alternate: Raised sill with sub sill Rough Opening From Subfloor Frame Height Standard Raised Sill 16 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Suggested Typical Installation Standard Window Sill (Inward Opening) INSTALLATION NOTES Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Unit must be installed in conformance with Dade County NOA documents. Installation Considerations The approximate weight of a panel is 4lbs/ft 2 (single glazing) and 5.5lbs/ft 2 (double glazing). The vertical structural deflection of the header should be limited to the lesser of L/720 of the span and 1/4 under full loads. Structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre- Installation Preparation and Installation Guidelines in the General Introduction and Owner s Manual with installation instructions available for this system. It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4. If not, both the dead and live loads need to be considered. Flush Standard Sill (Inward or Outward Opening) (No rating against wind driven rain or for air infiltration.) *FOR LOW PROFILE SADDLE SILL: For resistance against wind driven rain, the following is recommended by others. 1. Remove the gasket covering the inner channel. 2. Provide necessary weepholes at the bottom of the channels and on the outside face of the sill. 3. Make necessary drain connections. Ask NanaWall for a detailed drawing. Low Profile Saddle Sill* (Inward or Outward Opening) (No rating for air infiltration.) FFH FFH Surface Mounted Interior Sill See www.nanawall.com for details SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 17

SL35 Outward Opening Suggested Typical Installation All Cross Sectional Views Are Half Size INSTALLATION NOTES Head Jamb Suggested Typical Installation drawings shown are very general and may not be suitable for any particular installation. Product placement, fasteners, fl ashing, waterproofi ng, sealant, trim and other details for specifi c surrounding conditions must be properly designed and provided by others. Installation Considerations The approximate weight of a panel is 4lbs/ft 2 (single glazing) and 5.5lbs/ft 2 (double glazing). The vertical structural deflection of the header should be limited to the lesser of L/720 of the span and 1/4 under full loads. Structural support for lateral loads (both windload and when the panels are stacked open) must be provided. See Pre- Installation Preparation and Installation Guidelines in the General Introduction and Owner s Manual with installation instructions available for this system. It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4. If not, both the dead and live loads need to be considered. Rough Opening From Subfloor Unit Height Standard Raised Sill Panel Hinged At Side Jamb 18 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

All Cross Sectional Views Are Half Size SL35 Elevation and Section Drawings of Mulled Transoms As a guide, in low wind areas, a 3 high transom is possible with a 12 wide unit with Details 36 and 37. Note that the support profile must be anchored to the adjacent wall. For other applications, a structural beam will be needed between the folding unit and the fixed unit. Detail 36 Support profile between fixed SL45 transoms and SL35 unit for certain limited applications depending on size, configuration and structural loading Detail 37 Support profile between SL45 fixed bottom windows and SL35 unit for certain limited applications depending on size, configuration and structural loading Typical Elevation: I-3L with fixed transoms 36 Typical Elevation: I-3L with fixed bottom windows 37 Typical Stile and Rail with Double Glazing Typical Mullion Profile SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 19

SL35 Design Windload Chart (Derived From Comparative Analysis) Test Unit Size: 8 5 W x 7 4 H (3 panels) Please note that some jurisdictions may limit the use of these charts or may not accept them at all. Design pressures and/or sizes may be restricted to what was tested. Please also note that chart is only applicable for units with referenced Nana Wall supplied locking. 76 74 72 70 68 66 64 62 Positive and negative design pressures for both inward and outward opening units. Allowable Design Wind Loading - PSF 60 58 56 54 52 50 48 46 44 42 40 38 1 11 Unit Width Divided by Number of Panels 36 2 3 34 32 30 2 11 2 7 28 26 3 3 24 22 6 0 6 6 7 0 7 6 8 0 8 6 9 0 Panel Height 20 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Guide Specifications - Section 084113 SL35 NanaWall SL35, Aluminum Framed Folding System PART 1 - GENERAL 1.01 SUMMARY A. Section Includes: Engineered sliding/folding aluminum and glass door system, including aluminum frame, threshold, panels, sliding/folding and locking hardware, weather stripping, glass and glazing; designed to provide an opening glass wall, with sizes and configurations as shown on drawings and specified herein, NanaWall SL35, Aluminum Framed Folding System as supplied by NANA WALL SYSTEMS, INC. 1.02 REFERENCES A. American Architectural Manufactures Association (AAMA): 1. AAMA 611, Voluntary Specification for Anodized Architectural Aluminum. 2. AAMA 2604, Voluntary Specifications, Performance Requirements and Test Procedures for Pigmented Organic Coatings on Aluminum Extrusions and Panels. 3. AAMA 1303.5, Voluntary Specifications for Forced Entry Resistant Aluminum Sliding Glass Doors. B. American National Standards Institute (ANSI): 1. ANSI Z97.1, Safety Performance Specifications and Methods of Test for Safety Glazing Material Used In Buildings. C. American Society for Testing and Materials (ASTM): 1. ASTM E 283, Test Method for Rate of Air Leakage through Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 2. ASTM E 330, Test Method for Structural Performance of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference. 3. ASTM E 547, Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Cyclic Static Air Pressure Differential. D. Consumer Product Safety Commission (CPSC): 1. CPSC 16CFR-1201, Safety Standard for Architectural Glazing Materials. E. National Fenestration Rating Council (NFRC): 1. NFRC 100, Procedure for Determining Fenestration Product Thermal Materials. 1.03 SUBMITTALS A. Detail Drawings: Indicate dimensioning, direction of swing, configuration, swing panels, typical head jamb, side jambs and sill details, type of glazing material, and handle height. B. Product Data: Manufacturer s literature including independently tested data listing performance criteria and Owner s Manual with installation instructions. C. Contract Closeout Submittal: Submit Owner s Manual from manufacturer. Identify with project name, location and completion date, type and size of unit installed. 1.04 QUALITY ASSURANCE A. Manufacturer: Provide complete, precision built, engineered, pre-fitted unit by a single source manufacturer with at least 25 years experience in providing folding/sliding door systems for large openings in the North American market. 1. The manufacturer must have a quality management system registration to the ISO 9001: 2008 standard. SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 21

SL35 Guide Specifications - Section 084113 2. The manufacturer must have an environmental management system registration to the ISO 14001: 2005 standard. B. Performance Requirements: Provide from manufacturer that has independently tested typical units. Testing results to include air infiltration in accordance with ASTM E 283, water penetration in accordance with ASTM E 547, structural loading in accordance with ASTM E 330, and forced entry in accordance with AAMA 1303.5 and CAWM 300-96. ** SPECIFIER NOTE: Air infiltration and water penetration testing results can only be applicable if the unit matches the test unit in the direction of opening and the type of sill. Structural load testing results are only applicable for the test unit size and type of locking. (Comparative analysis charts published by manufacturer show which panel sizes (if any) would meet structural loading design pressures specifically required for the project). Forced entry testing results are only applicable for the test unit type of locking. See manufacturer s latest published data. C. Thermal Performance: Unit to comply with the U factor, simulated in accordance with NFRC 100, shown in manufacturer s latest published data for the glazing specified. D. Installer Qualifications: Installer experienced in the installation of manufacturer s products or other similar products for large openings. Installer to provide reference list of at least 3 projects of similar scale and complexity successfully completed in the last 3 years. 1.05 WARRANTY A. Provide manufacturer s standard warranty against defects in materials and workmanship. B. Warranty Period: Ten years for rollers and for seal failure of insulated glass supplied. For all other components, one year (two years if unit is installed by manufacturers certified trained installer) from date of delivery by manufacturer. 1.06 SITE CONDITIONS, DELIVERY, STORAGE AND HANDLING A. In addition to general delivery, storage and handling requirements specified in Section 01600, comply with the following: 1. Deliver materials to job site in sealed, unopened cartons or crates. Protect units from damage. Store material under cover, protected from weather and construction activities. PART 2 PRODUCTS 2.01 SUPPLIER NANA WALL SYSTEMS, INC. 100 Meadow Creek Drive, Corte Madera, CA 94925 Toll Free: (800) 873-5673 Telephone: (415) 383-3148 Fax: (415) 383-0312 Website: www.nanawall.com Email: info@nanawall.com 2.02 MATERIALS A. Frames and Panels: From manufacturer s standard profiles, provide head tracks, side jambs, and panels with dimensions shown on drawings. 1. Provide panels with standard one lite [OR with horizontal mullion(s) at specified height(s) from the bottom of the panel] 22 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Guide Specifications - Section 084113 SL35 2. Provide standard bottom rail 3. Aluminum Extrusion: Extrusions with nominal thickness of 059 (1.5 mm). Alloy specified as AIMgSi0.5 with strength rated as 6063-T5 or F-22 (European standard). Anodized conforming to AAMA 611, powder coated conforming to AAMA 2604. 4. Aluminum Finish: B. Glass: Select from NanaWall Powder Coating Finish Chart [OR dark bronze anodized] [OR clear anodized] [OR select from range of RAL high gloss powder coated finishes available from manufacturer] [OR select from range of RAL matte powder coated finishes available from manufacturer] [OR custom finish]. 1. All glass to comply with safety glazing requirements of ANSI Z97.1 and CPSC 16CFR 1201. Provide manufacturer s standard glass with dry glazing with glass stops on the inside only: 11/16 (18 mm) insulating clear safety [OR 11/16 (18 mm) insulating Low-E safety] [OR 3/16 (5 mm) tempered] [OR 3/16 (5 mm) laminated] [OR other glass available from manufacturer, including glass with other total thickness] 2. Provide manufacturer s standard glass spacers. Provide without capillary tubes [OR with capillary tubes]. C. Locking Hardware and Handles: 1. Main entry panel: On the main entry panel for models with a swing panel, provide manufacturer s standard L-shaped handles on the inside and outside, and a lock set with profile cylinder. Operation of lock set is by turn of key from the outside and with a thumbturn from the inside with a three point locking hardware operated by 180º turn of the handle. [OR on main entry pair of panels on inswing models without a swing panel, provide manufacturer s standard L-shaped handle on the inside, flat handle on the outside and lock set with profile cylinder. Operation of lock set is by turn of key from the outside and with a thumbturn from the inside with a two point locking hardware operated by 180º turn of the handle.] [OR on main entry pair of panels on outswing models without a swing panel, provide manufacturer s standard flat handle on the inside and on the outside and a lock set with a profile cylinder. Operation of lock set is by turn of key from the outside and from the inside with a two point locking hardware operated by 180º turn of the handle. SPECIFIER S NOTE: Key operation from the inside may not meet egress requirements.] [OR on main entry panel, provide manufacturer s standard flat handle on inside only with concealed two point locking hardware operated by 180 degree turn of handle. SPECIFIER S NOTE: Note that with this option, the main entry panel is operable from inside only and that there is no latch.] 2. On all other secondary panels, provide manufacturer s standard flat handles [OR removable custodial handles] and concealed two point locking hardware operated by 180 degree turn of handle. Face applied flush bolt locking will not be allowed. 3. Handle finish: Stainless steel L shaped and flat handles in a titanium black finish [OR stainless steel L shaped and flat handles in a brushed satin finish] [OR L shaped handles in a brown nylon finish and dark brown powder coated flat handles] SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 23

SL35 Guide Specifications - Section 084113 [OR L shaped handles in a gray nylon finish and silver gray powder coated flat handles] [OR L shaped handles in a white nylon finish and white powder coated flat handles] 4. Provide handle height centered at 41 3/8 [OR as specified] from bottom of panel. 5. Aluminum locking rods with standard [OR reinforced to meet higher structural loading] fiber glass reinforced polyamide end caps at top and bottom. Rods to have a stroke of 15/16 (24 mm). 6. If there are more than one unit, keyed alike [OR keyed differently]. D. Sliding/Folding Hardware: Provide manufacturer s standard combination sliding and folding hardware with top, bottom tracks and threshold. All running carriages to be with sealed, self-lubrication, ball bearing multi-rollers. Surface mounted hinges and running carriages will not be allowed. Weight of panels to be borne by the bottom of the track will not be allowed. 1. For each pair of folding panels: Provide cardanic, independently suspended, four wheeled coated with fiber glass reinforced polyamide upper running carriage and lower guide carriage. Running carriage to be adjustable in height, ¼ up and down. 2. Threshold: Raised sill in the same finish as panel finish [OR clear anodized flush sill] [OR dark bronze anodized flush sill] [OR clear anodized low profile saddle sill] [OR dark bronze anodized low profile saddle sill] 3. Provide on all four corners of panels, die cast zinc multi-functional corner fittings with carriage connectors, hinges and hinge pins as required. Finish: Powder coated, closest match to finish of frame and panels. SPECIFIER S NOTE: Note that as corner connectors are only available in powder coated finishes, if anodized panel and frame finishes are selected, there may be aesthetic issues. 4. Adjustment: Provide system capable of specified amount of adjustments without removing panels from tracks. E. Other Components: 1. Weather stripping: Provide manufacturer s standard double layer EPDM or brush seals with a two layer polyamide fin at both the inner and outer edge of door panels or on frame for sealing between panels and between panel and frame. Single layer weather stripping will not be allowed. 2. Provide machine screws for connecting frame components. 2.03 FABRICATION A. Use extruded aluminum frame and panel profiles with male-female interlocking, corner connectors and hinges, sliding and folding hardware, locking hardware and handles, glass and glazing and weather stripping as specified herein to make a folding glass wall. Factory pre-assemble as is standard for manufacturer and ship with all components and installation instructions. B. Sizes and Configurations: See drawings for selected custom dimensions within maximum frame sizes possible as indicated in manufacturer s literature. See drawings for selected number of panels and configuration. Inward [OR outward] opening unit. On configurations with a pair of swing panels, looking from inside, primary swing panel on the left [OR right] 2.04 ACCESSORIES (Edit for project requirements.) A. Provide the NanaScreen, a series of vertical, collapsible, pleated screen panels. Provide pleated screen material with floor tracking chain with ¼ (5 mm) floor track. See drawings for selected number of panels and configuration. Provide aluminum top track, side jambs, and vertical struts: 24 2012 NanaWall Systems www.nanawall.com SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE.

Guide Specifications - Section 084113 SL35 White powder coated [OR clear anodized] [OR dark bronze anodized] [OR powder coated select from range of RAL powder coated finishes available from manufacturer]. NanaScreen installation within opening [OR extended beyond opening] B. Provide other side lites, transoms, corner posts, or single or double doors as per drawings provided. PART 3 - EXECUTION 3.01 ERECTION A. Because of the large dimensions involved and the weight and movement of the panels, verify the structural integrity of the header such that the deflection with live load and dead loads is limited to the lesser of L/720 of the span and 1/4 (6mm). Structural support for lateral loads (both wind load and eccentric load when the panels are stacked open) must be provided. It is recommended that all building dead loads be applied to the header prior to installing the NanaWall. If so and if a reasonable amount of time has been allowed for the effect of this dead load on the header, then only the building s live load can be used to meet the above requirements of L/720 or 1/4 (6mm). If not, both the dead and live loads need to be considered. B. Examine surfaces of openings and verify dimensions; verify rough openings are level, plumb, and square with no unevenness, bowing, or bumps on the floor. C. Installation of units constitutes acceptance of existing conditions. 3.02 INSTALLATION A. Install frame in accordance with manufacturer s recommendations and installation instructions. Properly flash and waterproof around the perimeter of the opening. B. Installer to provide appropriate anchorage devices and to securely and rigidly fit frame in place, absolutely level, straight, plumb and square. Install frame in proper elevation, plane and location, and in proper alignment with other work. C. If necessary, provide drain connections from lower track. D. Install panels, handles and lock set in accordance with manufacturer s recommendations and installation instructions. E. If necessary, adjust hardware for proper operation. F. Accessories: Screens; install in accordance with screen manufacturer s recommendations and installation instructions. END OF SECTION DISCLAIMER: Nana Wall Systems, Inc. takes no responsibility for product selection or application, including, but not limited to, compliance with building codes, safety codes, laws, or fi tness for a particular purpose. The guide specifi cations is not intended to be verbatim as a project specifi cation without appropriate modifi cations for the specifi c use intended and the particular requirements of a specifi c construction project SPECIFICATIONS AND DETAILS SUBJECT TO CHANGE WITHOUT NOTICE. 2012 NanaWall Systems www.nanawall.com 25