SEISMIC CODE EVALUATION ST. LUCIA Evaluation conducted by Myron W. Chin

Similar documents
CHECKING MANUAL FOR THE EXAMINATION OF RESIDENTIAL PLANS AND INSPECTION OF RESIDENTIAL CONSTRUCTION IN GRENADA

KEEP YOUR FAMILY SAFER FROM EARTHQUAKES AND TYPHOONS BY MAKING SURE YOUR HOUSE FOLLOWS THESE 6 BASIC PRINCIPLES

Stone and Masonry Veneer

ORDINANCE NO BE IT ORDAINED BY THE CITY COUNCIL OF THE CITY OF BOULDER, COLORADO: CHAPTER 98 - Baled Straw Structures SECTION PURPOSE

SEISMIC RETROFITTING OF EXISTING BUILDINGS

Confined masonry. An illustrated guide for masons. This manual explains this technique. Confined masonry. RC frames. Columns first, walls after

CHAPTER 34 EXISTING BUILDINGS

Earthquake Resistant Construction Handbook

EMERGENCY MANAGEMENT PREPAREDNESS AND ASSISTANCE TRUST FUND ARC 4496 Evaluation Questionnaire

NSET EXPERIENCE ON SEISMIC RETROFITTING OF MASONRY AND RC FRAME BUILDINGS IN NEPAL

Product Information Bulletin

Structural Investigation Report

Details for Exterior Brick Masonry Veneer Supported by Metal Plate Connected Wood Trusses

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

2002 Advanced Building Products, Inc., P.O. Box 98, Springvale, Maine TEL: ; FAX: ; WEBSITE:

Anchor bolts ASTM F1554, Gr. 36 Wide flange beams ASTM A992, Fy = 50 ksi Misc. structural steel ASTM A36, Fy = 36 ksi

ENG.ACA.0001F Madras. New Zealand significant. (a) spandrel 2010) were solid

A. Coordinate concrete unit masonry (also termed CMU and block ) work with work before and after, especially:

0331 Brick and block construction

APPENDIX 1: UNDERSTANDING CAUSES OF COLLAPSE OF CONFINED MASONRY HOUSES IN INDONESIA

HOW CONFINED MASONRY BUILDINGS FAIL IN EARTHQUAKES

SECTION UNIT MASONRY

Volume 1. HOW TO MAKE A DREAM HOUSE EARTHQUAKE RESISTANT Contents

OECS Building Code. Grenada St Vincent & the Grenadines St Lucia Montserrat

DESIGN CATALOGUE FOR RECONSTRUCTION OF EARTHQUAKE RESISTANT HOUSES

Explain The Construction Of Framed Building In Earthquake Zones

Building Division Informational Handout

"Impact of New IS 1893 & Related Codes on Design of tall Buildings, Including Trend Setting Structures

RESIDENTIAL GARAGE AND DRIVEWAY

POST FRAME BUILDING STANDARDS

Documentation of the Seismic Evaluation and Retrofit Process

DESIGN AND MASONRY BASIC DESIGN GUIDELINES FOR CSEB. General principles for a good design

Pulaski County, Virginia Practical Wall Bracing

Building Design Data

Carroll County Bureau of Permits and Inspection Residential Code Compliance Guidelines Detached Garage

Construction applications

Christchurch City Council. PRK_3575_BLDG_001 Port Levy Fire Shed Detailed Engineering Evaulation Report

Shayne O Manning, P.E., S.E., LEED AP 2017 OBC STRUCTURAL OVERVIEW

Mandatory Wood Frame Soft-story Retrofit Program STRUCTURAL DESIGN GUIDELINES

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

Ductile Detailing for Earthquake Resistant R C Structures. Dr. S. K. PRASAD Professor of Civil Engineering S.J. College of Engineering Mysore

Safe Site 1 RUMÖH LÖEN SYURGA LÖEN

International Journal of Advance Engineering and Research Development REVISION OF IS: A REVIEW (PART 2)

1.02 STANDARD REFERENCES: The following standard specifications shall apply to the Work of this Section as indicated:

BUILDING PERMIT APPLICATION PACKAGE

Home Not Anchored to Foundation

CITY OF CEDAR FALLS DEPARTMENT OF DEVELOPMENTAL SERVICES INSPECTION SERVICES DIVISION PHONE Residential Accessory Structures

Seismic Behaviour of RC Shear Walls

Supplemental Plan Correction Sheet for LA Residential Code Prescriptive Design (2014 LARC)

Table 3. Detailed Comparison of Structural Provisions of IRC 2000 and 1997 NEHRP (Continued)

INSULATED CONCRETE MASONRY UNITS Section 04220

4.6 Procedures for Connections

STRUCTURAL ABBREVIATIONS S-001 GENERAL NOTES CONCRETE MASONRY NOTES DESIGN NOTES SOF NSWG-10 UAS SUPPORT FACILITY FY 2016 MILCON P-225

Tolerances for Concrete Construction. Tolerances for Concrete Construction. Tolerance 6/16/2015

TECHNICAL EVALUATION REPORT No. 27/2008/2060

Concrete Block Machines Typical Fixed Block Machine

STRUCTURAL DESIGN CRITERIA

REINFORCED CONCRETE MASONRY SECTION

HISTORICAL REVIEW OF MASONRY STANDARDS IN NEW ZEALAND

Structural Engineering

Technical Notes 11B - Guide Specifications for Brick Masonry, Part 3 Rev [Feb. 1972] (Reissued Sept. 1988) INTRODUCTION

You CAN Keep Your Family Safe In Future Earthquakes and Typhoons

SOUTH AFRICAN NATIONAL STANDARD

Ground + 4 floor RCC frame structure in Goa Floor to floor height is 3.0m Plan dimension, 24.0 m x 13.5 m SBC = 20 t/sqm, hard Strata is consider for

City of Tacoma Planning and Development Services

Contents. Tables. Terminology and Notations. Foreword. xxi

Masonry Veneer - Chapter 6. Masonry Veneer Anchored Veneer

NCMA TEK TEK 19-5A FLASHING DETAILS FOR CONCRETE MASONRY WALLS

Village of Glencoe 675 Village Court, Glencoe, Illinois

Nortrax Section David Manchester Road, Ottawa NON-STRUCTURAL METAL FRAMING 16 May 2014 Page 1

Openings in Walls I: Reinforcement

Intermediate Mapping Grid: CPC30211 Certificate III in Carpentry

BUILDING INTEGRITY SUMMARY REPORT

04221 CONCRETE UNIT MASONRY

WALL SYSTEMS ( Ref: The Building Illustrated, Ching, Francis DK )

New Zealand Concrete Masonry Manual

Custom 22' x 40' - 16' Tall Garage Plan #g227 By SDS-CAD Specialized Design Systems

SUBJECT: NEW 2000 INTERNATIONAL RESIDENTIAL CODE (IRC) DATE:

ACCESSORY STRUCTURE Building permit information For 1 & 2-family dwellings

SECTION NON-STRUCTURAL METAL FRAMING

Custom 30 x 48-14' Tall Garage Plan #g226 By SDS-CAD Specialized Design Systems

Signage Code. H101.2 Signs exempt from permits. The following signs are exempt from the requirements to obtain a permit before erection:

6.2 Stabilization through mass Rammed earth walls 60 to 100 cm thick, which are not too high, can withstand horizontal seismic shocks without addition

Technical Assistance by JICA TRANSITIONAL PROJECT IMPLEMENTATION SUPPORT FOR EMERGENCY RECONSTRUCTION PROJECTS IN NEPAL

GARAGE MAIN FLOOR PLAN

No structural deficiencies were observed to the west exterior elevation.

Technical Version: 1 December 2009 PERFORMANCE OF STEEL FRAMES IN EARTHQUAKES

i-act: Health and Safety Regulations, Roles and Responsibilities i-act: Dealing with Accidents and Illnesses

7 NON-STRUCTURAL ELEMENTS

Learning from Earthquakes to Improve Rehabilitation of Reinforced Concrete Buildings. James O. Jirsa The University of Texas at Austin

Evaluation Report CCMC R Superior Walls Xi Precast Concrete Insulated Wall Panels

Note on the assessment:

Elevations. Front Elevation. Left Elevation. Back Elevation. Right Elevation CEDAR RIDGE H O M E S. Total Sq Ft = 1,647.

Residential Building Inspections

ISSUE A Code Change # 2 Class 3 and Class 4 Buildings

Detailed Assessment of St. Patrick Church, Paraparaumu, NZ. 09 January 2013 MIL Phase 05

PENNSAFE BUILDING INSPECTION SERVICES LLC Deck and Roof Cross Section Submittal

DISASTER-RESILIENT HOUSING DESIGN AND CONSTRUCTION STRATEGIES

REINFORCING TABLES INSTALLATION MANUAL

Unit 4 Brick Masonry. Part Ⅰ Illustrated Words and Concepts. Figure 4-1 Basic Vocabulary of Bricklaying

Transcription:

SEISMIC CODE EVALUATION ST. LUCIA Evaluation conducted by Myron W. Chin NAME OF DOCUMENT: The St. Lucia Building Code [1.01] This code is also known as the Organization of Eastern Caribbean States (OECS) Code. It has been adapted and adopted by each individual island state as its own code. It is in this context that it is here also described as the St. Lucia Building Code. Separate legislation is therefore designed to give it legal standing in each territory. YEAR: October 2001 GENERAL REMARKS: The principal reference Code is the Caribbean Uniform Building Code (CUBiC) [102]. The Code is administered by the Development Control Authority of St. Lucia and shall take precedence over any other building code or standard. CONTENTS: The details are set out in the following sections: Section 1 - Administration of the Code Section 2 - Definition Section 3 - General Requirements Section 4 - Materials and Construction Standards Section 5 - Public Health and Safety Section 6 - Precaution During Building Construction Section 7 - Water Supply Services Section 8 - Sewage and Waste Water Disposal Section 9 - Plumbing Section 10 - Solid Waste Disposal Section 11 - Electrical and Mechanical Installation Section 12 - Loads Section 13 - Excavations and Foundations Section 14 - Timber Construction Section 15 - Concrete Block and Masonry Construction Section 16 - Plain and Reinforced Concrete Section 17 - Structural Steel Section 18 - Small Buildings 1

SPECIFIC ITEMS: Note: Bracketed numbers refer to Code s specific chapters or articles. [ ] Parenthesis numbers refer to item of this document. ( ) 1. SCOPE 1.1 Explicit concepts and limitations [102.1] the code shall apply to design and construction of new buildings and alteration, reconstruction, demolition, removal, relocation, maintenance and occupancy of existing buildings or any appurtenances connected or attached to such buildings or structures. [102.1] the principal reference code is the caribbean uniform building code (cubic). [102.2] it is not intended to supersede or amend legislation in force in st. lucia. developer must consult other listed legislation. 1.2 Performance Objectives No Specific Performance Objectives are given. EARTHQUAKE LOADS [1203] 1203.1 Basis of Design a) The record of seismic activity within the last 100 years shows that there have been earthquakes which have created significant damage in some of the islands in the Eastern Caribbean. In the past twenty-five years Islands such as Antigua, St. Kitts and Montserrat have experienced earthquakes which have caused damage to buildings and other property. b) It is necessary therefore that every building and structure and every portion thereof be designed and constructed in accordance with Part 2 Section 3 of the Caribbean Uniform Building Code (CUBiC) or in 2

accordance with any other Code or Standard approved by the Director.1 c) For the design of small buildings to resist seismic forces see Section 18 of this Code and Section A of the Building Guidelines. 1203.2 Building Response Data from Future Earthquakes In order to develop earthquake resistant design recommendations more specific to each of the OECS, building response data must be obtained from future earthquakes. The installation of at least three strong motion accelerographs is recommended in all buildings six storeys or more in height. Where provided, accelerographs are to be distributed between ground and roof. RECOMMENDATIONS FOR CODE DEVELOPMENT Since the principal Reference Code is CUBiC which is itself being considered for revision, the OECS Building Code can be considered outdated, and it is recommended that the provisions of the proposed updated CUBiC 2000 should be incorporated into the OECS model code. 1 The appropriate zonal coefficient for St. Lucia taken from Table 2.305.1of CUBiC is 0.75 3

SEISMIC CODE EVALUATION ST. LUCIA Evaluation done by Myron Chin NAME OF DOCUMENT: OECS Building Guidelines (Minimum Standards for the Construction of Small Buildings) YEAR: 2001 GENERAL REMARKS: Guidelines developed for building and construction in keeping with acceptable building practices in the OECS. These Guidelines are based primarily on the reports of the construction industry workshops held in 1985 and 1986 in Antigua, Anguilla, British Virgin Islands, Dominica, Montserrat, St. Kitts/Nevis and St. Vincent. Other engineers and architects in the OECS and the Turks and Caicos Islands have contributed to the present document, building on the work previously carried out by the Pan Caribbean Disaster Prevention Preparedness Program (PCDPPP). CONTENTS Section A - General Construction Principles including earthquake and hurricane consideration. Section B - Concrete Construction. Section C - Timber Construction. Section D - Steel Construction. Section E - Fire Prevention and Fire Safety. Section F - Plumbing, sanitation, water supply and gas installation. Section G - Electrical Guidelines. Section H - Administration of the Guidelines. 3.1 Earthquake Resistant Construction 3.1.1 General 3.1.2 Effect of Soil Type 3.1.3 Effect of High Seas 3.1.4 Building Shape 3.1.5 Appendages 4

3.2 Rules for Construction of Earthquake Resistant Buildings 3.2.1 Location of Openings 3.2.2 Masonry Buildings 3.2.3 Steel Buildings 3.2.4 Timber Buildings 3. EARTHQUAKE AND HURRICANE CONSIDERATIONS 3.1 Earthquake Resistant Construction 3.1.1 General a) It is widely recognised in the building industry, that many of the Caribbean Islands are in an earthquake zone and have suffered varying degrees of damage due to earthquakes. b) Because of this situation, buildings must be designed and constructed so that they have some resistance to the shaking or lateral forces produced by earthquakes. 3.1.2 Effect of Soil Type a) The type of soil at the site may have a significant effect upon the resistance of the building to an earthquake. However for buildings within the scope of these Guidelines the effect of the soil type is not so significant provided that the building is not constructed on loose saturated sands, which may liquefy during an earthquake and cause collapse of the building. b) The earthquake may also, due to shaking of the ground, compact loose sands or fill material, and if a building is constructed on such material, the building will be damaged. 3.1.3 Effect of High Seas Buildings on coastal areas may suffer due to high waves produced by earthquakes, and therefore the siting of the building in relation to the sea level is very important. 5

3.1.4 Building Shape a) The success with which a building survives an earthquake is greatly affected by its shape in plan, the way the building is tied together and the quality of construction. b) Most buildings with a simple rectangular shape with no projections (or only short projections) perform well under earthquake conditions provided the construction is adequate. c) Long narrow buildings should be avoided by limiting the length to three time the width. If the building must be longer, then it should be divided into separate blocks with adequate separation. Figure A-1 illustrates desirable and undesirable plan shapes. d) Rectangular buildings with well inter-connected cross walls are inherently strong and therefore desirable. 3.1.5 Appendages Where buildings have decorative or functional additions or appendages such as window hoods, parapets and wall panels etc. extreme care must be taken to ensure that they are securely fixed, since many of such items tend to fall easily and may cause damage during an earthquake. 3.2 Rules for the Construction of Earthquake Resistant Buildings It is recommended that the following rules be followed for the construction of buildings in earthquake prone areas: 3.2.1 Location of Openings a) The location and size of openings in walls have a significant effect upon the strength of a wall and its ability to resist earthquake forces. b) Openings are to be located away from a corner by a clear distance to at least 1/4 of the height of the opening. It is recommended that the minimum distance be 15". c) The total length of the openings should not exceed 1/2 the length of the wall between consecutive cross walls. (See figure A-2). 6

d) The horizontal distance between two openings should not be less than 1/2 the height of the shorter opening. (See fig. A-2) For two storey buildings, the vertical distance from an opening to one directly above it should not be less than 2'-0", nor less than one half the width of the smaller opening. 3.2.2 Masonry Buildings An important factor contributing to the earthquake resistance of concrete masonry buildings is the detailing and placing of steel reinforcement. The design of a reinforced concrete frame building should be undertaken by experienced engineers. The reinforcing guide given in this section therefore must only be used for simple single storey buildings constructed of good quality concrete blocks. The minimum quantities of reinforcing to be used, have been set out in Section B Subsection 3.4. The following is a checklist which should be used to ensure that all necessary steps have been taken: a) Vertical reinforced columns should be placed in all masonry walls with a maximum dimension between columns of 16 ft. b) All exterior walls should be reinforced as shown in 3.4 of Section B. Interior walls also require reinforcement for earthquakes. c) All vertical wall reinforcement must be securely fixed to the foundation and belt course. d) Where vertical reinforcement is not a continuous bar, adequate lap lengths are to be provided and securely tied. (See Table B-1). Minimum lap length for a 3/8" bar should be 1'-6". e) Reinforced block work cores are to be filled after the laying of every three courses with well compacted concrete, or poured grout. f) In addition to the minimum vertical wall reinforcement, All the corners and junctions of the wall will be reinforced (Figs A-3 and A-4). g) All vertical reinforcement is to be securely fixed to the ring beam. Horizontal reinforcement must be placed every 3 courses. 7

h) Window and door jambs should be reinforced and tied into the lintels. i) Gable walls are to be reinforced by bars fixed to the concrete beam at eaves height and to the sloping ring beam at the top of the gable. (Fig. A-5). 3.2.3 Timber Buildings Although the foregoing principles apply to concrete block buildings, there are two additional areas of concern with respect to timber buildings: a) All corners and intersections must be adequately braced. b) Earthquake forces tend to remove timber buildings from their supports by shaking. Because of this it is important to securely fasten sills to foundations. 3.2.4 Steel Buildings a) While steel buildings are generally beyond the scope of these Guidelines, it should be noted that the natural ductility of steel protects the frame itself from severe damage. b) However, in many cases concrete block walls are used and the precautions already listed for these walls will apply. The wall reinforcement must now be anchored by welding to the steel columns and beams, or the steel frame encased in concrete in which case the wall reinforcement can be tied into the concrete cage encasing the steel frame. RECOMMENDATIONS FOR CODE DEVELOPMENT Since the Small Buildings Code of Trinidad and Tobago (SBCTT) has included and updated most of the provisions of the OECS Building Guidelines, it is recommended that the provisions of the proposed SBCTT should be incorporated into the OECS Building Guidelines. 8