The Energy Audit National Weatherization Training Conference Priority Lists Experiences and Impacts Nick Milano

Similar documents
Kentucky WAP QCI Final Inspection Checklist

COAD Ohio Weatherization Training Center Course Overview

Home Energy Score. Learn more at homeenergyscore.gov. Uses more energy. Uses less energy Milvia Street Berkeley, CA 94704

Quality Control Inspection Checklist. WX Contractor: BWR: Yes / No DCF: Yes / No Work Order: Yes / No

W02 Designing a Priority List

1. PREINSPECTION RESIDENTIAL ENERGY EFFICIENCY 7

Compliance Certificate

Module number 6 provides an on-line, self-paced training seminar on energy efficiency and energy conservation for residential buildings.

Rebates for Improvements Home Efficiency Program Fort Collins Utilities

Home Energy Score Report

WAP Draw Review Guide

Energy Compliance Information

Energy Compliance Information

Wx Process. Wx PROCESS. Weatherization Assistance Program Indiana Field Guide. Chapter 1 Wx Process 1-1

Compliance Certificate

2009 IECC with St Louis Amendments. Fenestration U-factor Skylight U-factor Glazed fenestration SHGC NR 0.

ENERGY EFFICIENCY CERTIFICATION

Compliance Certificate

Technical Management Areas

Energy Code Inspection Checklist

Fenestration Components: Mechanical Summary. Water heater energy factor: Ef Fuel type: Gas Electric Other

Effective Date: April 25, 2016 Revised: November 7, 2017

Oregon High Performance Home Requirements

2015 MICHIGAN UNIFORM ENERGY CODE Effective: February 8, 2016

Energy Code Inspection Checklist

REScheck Compliance Certificate Massachusetts Energy Code REScheck Software Version 3.6 Release 1 Data filename: O:\REScheck 38\38258.

REScheck Software Version Compliance Certificate

Feature Zone IECC 2009 IECC

Measure 1 Seal Ducts Components Inspected

IECC Residential Significant Changes Summary. Tier I

Retrofit Installer / Shell

REQUEST FOR PROPOSALS May 15, 2017 Weatherization Assistance Program Energy Audit Services Dakota County, Minnesota

REScheck Software Version Compliance Certificate

COMMERCIAL ENERGY EFFICIENCY

Energy Efficiency Requirements 9.36

Town of Farragut RESIDENTIAL CONSTRUCTION ENERGY EFFICIENCY. LAST UPDATE: July 03, 2014

Plan Check & Field Inspection Guide

Questar ThermWise Duct Technical Specifications

Appendix. Home Heating Analysis Worksheet. Introduction. Directions C-1

Hardin County Planning and Development Commission

About Active Energy Engineering

Residential Data Collection Checklist 2009 International Energy Conservation Code Climate Zone 2

Success with 2012 NC Energy Conservation Code in North Carolina: Tech Tips for Builders. insulation

Supplementary Standard SB-12. Energy Efficiency For Housing

INSULATION SUCCESS WITH 2012 IECC DELAWARE. for Builders & Trades. Recommended Practices for Optimized Energy Savings

A Closer Look Inspection Service 2015 IECC Residential DFW area handout

9.36 Energy Efficiency

Please Submit Plans and Forms Electronically.

Neighbors Warming Neighbors

Commonwealth of Massachusetts

2012 Illinois Energy Conservation Code Applications

CHAPTER 1: OVERVIEW OF ENERGY EFFICIENT CONSTRUCTION

David A. Andersen & Associates

Date Rater Verified. Rater Verified. Slab / Pre-Drywall / Thermal Inspection

2010 National Building Code Adoption and Associated Process Changes

For more information about Ground Source Heat Pumps, call the Member Service Department at or visit our website at

RESIDENTIAL ENERGY CODE. The 2015 International Energy Conservation Code (IECC) as modified below.

New Hampshire Residential Energy Code

ORDINANCE NO. XXXX BE IT ORDAINED BY THE GOVERNING BODY OF THE CITY OF LAWRENCE, KANSAS:

SpacePak Manual J Load Analysis Project Sheet

Administrative Changes

Boulder City NV Prepared by (Print Name) Signature Date

INFORMATIONAL HANDOUT FOR FINISHING A BASEMENT

FIELD COPY ATTACHMENT

Success with Louisiana Energy Code. Techtips for Builders/Trades & Code Officials INSULATION

FOR ADDITIONS and REMODELS Before filling out this application, read Green Building & Green Points Guideline Booklet for more in-depth information.

HOME ENERGY SURVEY 3/6/2014. PREPARED FOR: Martha Stewart 78 Maple St. Alden, IL PREPARED BY: Johnny Tester on behalf of CLEAResult

SectIon Energy Effldency

2012 INTERNATIONAL ENERGY CONSERVATION CODE ADOPTION TOOLKIT OCTOBER 2012

Supplementary Standard SB-12. Energy Efficiency For Housing

Michigan Energy and Cost Savings

The effect of Building Regulations (Part L1 2002) on existing dwellings

The Inspection Process. Waxhaw N.C.

Truing-Up to Billing Data

Residential Energy Code Update

Building Envelope

COST AND BENEFIT ANALYSIS OF PROPOSED CHANGES FOR ENERGY EFFICIENCY IN HOUSING AND SMALL BUILDING IN THE NATIONAL BUILDING CODE

Energy Merit Badge Workbook

FLORIDA BUILDING CODE, ENERGY CONSERVATION Residential Building Thermal Envelope Approach FORM R

Table Air Barrier and Insulation Inspection Component Criteria

2012 Ontario Building Code Requirements for New Construction. Bradford West Gwillimbury Building Division March 5, 2012

2014 British Columbia Building Code Changes

Energy Efficiency Programs

Work Order (Bid Form) Upper East Tennessee Human Development Agency

Renovating for energy savings

InterNACHI Home Energy Survey Provider Operation Policies and Procedures

REQUIREMENTS FOR SUBSTANTIALLY DAMAGED AND SUBSTANTIALLY IMPROVED STRUCTURES

Residential Requirements of the Texas Energy Code 2009 IRC Chap 11

Home Energy Assessment Rebate Guide

Energy Efficiency: Designing Wood-Frame Buildings for Occupant Comfort

ENERGY AUDITOR STUDY GUIDE

INSULATION. Success with 2015 IECC Northeast & Mid-Atlantic. Techtips for Builders & Trades

HCM UNIVERSITY OF ALASKA FAIRBANKS Building Challenges in Alaska UNIVERSITY OF ALASKA FAIRBANKS

Residential New Construction Simulated Performance Alternative (SPA) Guide Updated 1/12/2019

CARRP (COMMUNITY AUDIT AND RETROFIT REBATE PROGRAM) Build Better, Build Smart Community Series II August 12, 2010

Table 1. Insulation Type and R-Values. Avg. R-Value Per Inch (h*ft 2 *deg F/Btu*in)

Success with 2009 IECC in Georgia: Tech Tips for Builders. Insulation. Copyright 2014 Advanced Energy. All Rights Reserved

Final 2016 UDRH Inputs: Addendum to Massachusetts Single- Family Code Compliance/Baseline Study DOCUMENT TITLE.

A. GENERAL INFORMATION

Energy Provisions of the Kentucky Residential Code. Guide for Homeowners

Transcription:

2009 National Weatherization Training Conference Priority Lists Experiences and Impacts Nick Milano The Energy Audit Except for materials to eliminate H&S hazards all weatherization materials installed must be cost effective. The materials must result in energy cost savings over their life, discounted to present value, that equal or exceed the cost of the materials. SIR = 1 or higher. The energy audit must assign priorities among individual wx measures in descending order of their cost effectiveness. Adjust for interaction between measures to decrease the estimated fuel cost savings for lower priority measures. Eliminate measures that are no longer cost effective as adjusted for interaction. Compute the cost of fuel saved per year. Be approved by DOE

Priority Lists - For similar dwelling units without unusual energy consuming characteristics, energy audits may be accomplished by using a priority list developed by conducting site specific energy audits of a representative subset of these dwelling units. - States also must provide the input data and list of wx measures recommended by the audit software or manual methods for several dwelling units from the subset. For DOE approval States must: - Describe how the priority list was developed - How the subset of similar homes was determined - Circumstances that will require site specific audits States must resubmit their energy audit procedures / priority lists to DOE for approval every five years. Ohio Building Types TYPE A Wood Frame Home with Full Basement and Open Joist Attic TYPE B Wood Frame Home with Crawl Space and Open Joist Attic TYPE C Wood Frame Home with Combination Crawl Space/Basement and Open Joist Attic TYPE D Wood Frame Home with Slab Foundation and Open Joist Attic TYPE E Wood Frame Home with Full Basement and Kneewall Attic TYPE F Wood Frame Home with Post Foundation and Open Joist Attic TYPE G Block, Concrete, or Log Home (Solid Wall) with Slab Foundation and Open Joist Attic TYPE H Mobile Home with Post Foundation TYPE I Block, Concrete, or Log Home (Solid Wall) with Basement and/or Crawl Space and Open Joist Attic

REQUIRED MEASURES LIST FOR 1-4 UNIT BUILDINGS -Uniform Measures [1] -Uninsulated Ceilings with less than an effective R-19, insulate to R-38 -Uninsulated Walls to R-15 -Uninsulated Floors to R-19 [3] or perimeter insulation to R-11 in crawl spaces, basements -[1] Includes measures presumed cost effective as identified in Ohio's waiver audit approval request: -Air Leakage (as determined by required blower door testing) -Water Heater Insulation (always installed unless a technical or safety problem exists which is beyond the scope of WAP to correct) -Furnace Tune-up (as determined by diagnostic equipment and required inspection procedures) -Duct Insulation in non-conditioned areas -Duct Sealing -Low-flow Showerhead (as determined by inspector and client) -Incidental energy - related repairs that do not exceed $600.00. -Energy - related Health and Safety measures. OPTIONAL MEASURES LIST FOR 1-4 UNIT BUILDINGS -Partially Insulated Attics with existing insulation equal to or greater than an effective R-19 -Storm Windows over single pane windows -Thermal Vent Damper -Electric Vent Damper -Intermittent Ignition Device (IID) -Electric Vent Damper plus IID -Flame Retention Burner -Replacement Heating System (for efficiency improvements) -High Efficiency Furnace (for efficiency improvements) -Optional measures are measures that are to be selected by NEAT, but cannot be installed unless achieving a SIR of 1 or greater, as described in Ohio's waiver audit approval request. REQUIRED MEASURES LIST FOR MANUFACTURED UNITS (Mobile Homes) Shell Measures (Based upon DOE's approval of Ohio's priority list from MHEA) Type- Bowstring Roof with Longitudinal Floor Joists Natural Gas Heating Fuel -The existing ceiling insulation is less than an effective R-9 -The existing wall insulation is less than an effective R-5 -The existing floor insulation is less than an effective R-5 All Other Heating Fuel Types -The existing ceiling insulation is less than an effective R-11 -The existing wall insulation is less than an effective R-5 -The existing floor insulation is less than an effective R-7

Mobile Homes (cont.) Type- Factory-Built Pitched Roof with Transverse Floor Joists and 2" x 6" walls Natural Gas Heating Fuel -The existing ceiling insulation is less than an effective R-19 -The existing wall insulation is less than an effective R-16 -The existing floor insulation is less than an effective R-11 All Other Heating Fuel Types -The existing ceiling insulation is less than an effective R-19 -The existing wall insulation is less than an effective R-16 -The existing floor insulation is less than an effective R-16 A MHEA audit must be run for structures outside of these construction details Mobile Homes (cont.) The following are mandatory on all units: -Air Leakage (as determined by required blower door testing) -Water Heater and hot water pipe insulation (always installed unless a technical or safety problem exists which is beyond the scope of WAP to correct) -Furnace Tune-Up (as determined by diagnostic equipment and required inspection procedures) -Duct Sealing (as determined by visual inspection and duct testing procedures as outlined in the Weatherization Program Standards) -Low flow Showerhead (as determined by inspector and client) -Incidental energy related repairs that do not exceed $600.00, including labor and materials. -Energy related Health and Safety measures PRIORITY LIST FOR INDIVIDUALLY-HEATED MULTI-FAMILY BUILDINGS WITH 5 OR MORE UNITS, BUT WITH 3 OR LESS STORIES ABOVE GRADE (LOW RISE) Subject to Priority Rating by Housing Type applicable to 1-4 unit buildings Uniform Measures -Uninsulated Ceilings with existing insulation less than R-19, insulate to R-38 -Uninsulated Walls to R-15 -Uninsulated Floors to R-19 -Uninsulated Perimeters to R-11 Other Measures -Incidental energy related repairs that do not exceed $600 including labor and materials. -Energy - related Health and Safety measures. However, an investment on the part of the building owner is required.

CENTRALLY HEATED MULTI-FAMILY BUILDINGS Centrally heated multi-family buildings with 5 or more units or buildings with 4 stories or more (High Rise), will be treated based on EA-QUIP audit results and will still require the Office of Community Service's prior written authorization. Typical Measures: -Tune up and repair of the central heating system, distribution system -Tune up and repair of the central domestic hot water system -Attic insulation -Wall insulation -Basement/Crawlspace insulation -Air sealing -Electric Baseload NEAT & MHEA How Did We Get There The basis of our submission Ohio is predominately a heating climate 6398 H.D.D. Ashtabula 4912 H.D.D. Portsmouth Heating Degree Days - find the day's average temperature by adding the day's high and low temperatures and dividing by two. If the number is above 65, there are no heating degree days that day. If the number is less than 65, subtract it from 65 to find the number of heating degree days. Used the warmest location Used the highest fuel costs The assumption is if the measure is cost effective in the warmest climate at the highest fuel cost then it will be cost effective in all other cases. Sent 37 audits to DOE for approval Ran approximately 72 audits to arrive at 37 audits Why Ohio Uses a Priority List Saves Time Time is Money Simplifies the Training Effort Auditor has more time for other activities Provides Consistency PY 08 7880 homes PY 09 8052 homes ARRA 09-11 32,000 homes 10,667 / year