Passive Houses in South West Europe

Similar documents
Optimization of air tightness and night ventilation for Passive houses in Italian climates under Fanger and Adaptive comfort models

St Loyes Extra Care Facility PHPP Pre-Assessment Report

Passive house optimization for Southern Italy based on the New Passivhaus Standard

Modelling Analysis of Thermal Performance of Internal Shading Devices for a Commercial Atrium Building in Tropical Climates

PASSIVHAUS Designed for you to enjoy maximum comfort with minimum energy.

The main mode of air change of rooms is Ventilation. Ventilation and Energy maybe not that irreconcilable. articles

Passivhaus Projects and Benefits

JOTUN Cool Shades. Impact of the TSR Value on the Users Comfort and the Energy Performance of Buildings. ai³ Werner Jager

Passiv Haus Institut. Certification as "Quality Approved Passive House" Criteria for Non-Residential Passive House Buildings

Dienstleistung. Certification as "Quality Approved Passive House" Criteria for Residential-Use Passive Houses

IMPACT OF USING DIFFERENT MODELS IN PRACTICE A CASE STUDY WITH THE SIMPLIFIED METHODS OF ISO STANDARD AND DETAILED MODELLING PROGRAMS

Traditional and passive house energy footprint calculation methods

Chapter 6. Space heating load

COMFORT-PRODUCTIVITY Building costs COMFORT-PERFORMANCE. Radiant Heating and Cooling Systems for Better Comfort and Energy Efficiency INDOOR - OUTDOOR

4.2.3 MINERGIE ORIGIN AND ORGANISATION

ANALYSIS OF ENVELOPE THERMAL BEHAVIOUR THROUGH PARAMETRIC STUDIES. Civil Engineer, PhD, Assistant Professor, Civil Engineering Department (3)

Ventilative Cooling potential tool

Summer thermal comfort in traditional buildings of the 19th century in Florina, north-western Greece

Thermal insulation of buildings and cooling demand

Built examples and project certification. Zeno Bastian, Passive House Institute

COMPARISON OF TWO PASSIVE HOUSE SCHOOLS IN NORWAY AND GERMANY

carbon-neutral architectural design Pablo La Roche CRC Press Taylor & Francis Croup Boca Raton London NewYork CRC Press is an imprint of the

Minimum Energy Consumption 84% energy heating savings*

Catalogue of Learning Targets

GREEN BUILDING CONGRESS 2011 NEW DELHI

PRINCIPLES AND POTENTIALS OF VENTILATIVE COOLING

PHPP Report. Beattie Passive Inchkeith Drive

PASSIVE SOLAR OFFICE BUILDING: FIRST EXPERIENCES AND MEASUREMENTS

HUMAN-BEHAVIOR ORIENTED CONTROL STRATEGIES FOR NATURAL VENTILATION IN OFFICE BUILDINGS

PASSIVE HOUSE OBJECT DOCUMENTATION

F. Flourentzou Lefkosia new townhall passive bioclimatic Minergie design. Flourentzos Flourentzou: Innovation park EPFL Lausanne, Switzerland

BUILDING DESIGN AND THERMAL INERTIA: WHEN, WHY, WHERE

PassiveDesign.org. Principles of Passive Design

Passivhaus Introduction

COMPARISON OF ENERGY USE INDICATORS OF A NON-RESIDENTIAL PASSIVE HOUSE WITH ASHRAE 90.1 BUDGET BUILDING

Simplified methods to evaluate energy use for space cooling in the energy certification

Could a European Super Energy Efficient Standard Be Suitable for the U.S.? John Broniek, IBACOS BEST1 CONFERENCE June 12, 2008

Using passive solutions to improve thermal summer comfort in timber framed houses in South-west France

EnerPHit. Criteria for Residential-Use Refurbished Buildings

OPERATION AND CONTROL OF THERMALLY ACTIVATED SLAB HEATING AND COOLING SYSTEMS

INTEGRAL BUILDING AND ENERGY DESIGN OF AN OFFICE BUILDING COMPARISON OF INITIAL DESIGN IDEAS WITH MONITORED RESULTS

Assessing thermal comfort of dwellings in summer using EnergyPlus

71 kwh/(m²a) Project Documentation. 1 Abstract. Single family house in Bellbrae, Victoria, Australia. 1.1 Data of building. Year of construction

The Centre for Sustainable Building (ZUB) * A Case Study

Thermal comfort under transient seasonal conditions of a bioclimatic building in Greece

Catalogue of Learning Targets. Certified PHPP Expert

Nearly Zero Energy Building in Lecco Modern technological building compared to an ancient Villa

Experimental Study to Evaluate the Performance of Iraqi Passive House in Summer Season

Analysis of different shading strategies on energy demand and operating cost of office building

546: High Altitude Design, Optimising Residential Architecture in the Alborz Mountains, Iran

STEADY STATE AND DYNAMIC THERMOPHYSICAL PARAMETERS OF TRANSPARENT BUILDING COMPONENTS

SUMMER THERMAL COMFORT IN TYPICAL FRENCH RESIDENTIAL BUILDINGS: IMPACT ASSESSMENT OF BUILDING ENVELOPE INSULATION ENHANCEMENT

Results from the Application of the Maltese Energy Performance Rating of Dwellings in Malta EPRDM Software to a New Block of Apartments

EUROPEAN MYTHOLOGY AND HELLENIC REALITY ABOUT ZERO ENERGY BUILDINGS

Assessment of the energy demand in energy-saving office buildings from the viewpoint of variations of internal heat gains

Thermal Thermal Applications Category Version 6.4. Integrated Environmental Solutions

COMFORT DRIVEN ADAPTIVE WINDOW OPENING BEHAVIOR AND THE INFLUENCE OF BUILDING DESIGN

Deakin Research Online

Study of the energy performance of a retrofitting office

Passiv Haus Institut Dr. Wolfgang Feist PEP Project Information

IESVE Compliance for ASHRAE IES Virtual Environment

PASSIVE HOUSE. is a building, which doesn t need an active type of heating. Dr. Ing Mihail Stancu

Analysis of Heating Energy of Ventilation Systems in Non- Residental Passive Houses in Estonia

Apartment building Sodastraße 40 in Ludwigshafen, DE

ENERGY EFFICIENT TECHNIQUES AND SIMULATION OF ENERGY CONSUMPTION FOR THE SHANGHAI ECOLOGICAL BUILDING

The WHY House Rethinking the Passivhaus Standard in a subtropical climate

Design and retrofitting of a hybrid building in Athens

USE OF COOL ROOF TO REDUCE THE ENERGY DEMAND AND CONSUMPTION OF COMMERCIAL BUILDINGS AT MEDITERRANEAN LATITUDES

GREEN AND COOL ROOFS URBAN HEAT ISLAND MITIGATION POTENTIAL IN EUROPEAN CLIMATES FOR OFFICE BUILDINGS UNDER FREE FLOATING CONDITIONS

Analysis of Night Ventilation Potential for Residential Buildings in Hot-Humid Climate of Malaysia

Measurements of Energy Performance and Indoor Environmental Quality in 10 Danish Passive Houses Larsen, Tine Steen; Jensen, Rasmus Lund

The Effects of Set-Points and Dead-Bands of the HVAC System on the Energy Consumption and Occupant Thermal Comfort

Reducing energy demand in non-domestic buildings: integrating smart facades, ventilation, and surface heating and cooling

Simulation Assisted Monitoring of a Multi-Family House a renovation case study

Thermal comfort analysis in a passive house using dynamic simulations*

Chapter 7. Passive Solar Contents

Retrofitting Adaptive Comfort Strategies into Conventionally Air Conditioned Commercial Buildings

A Parallel between the Brazilian Energy Labelling System and the Passivhaus Standard for Housing

Advanced Ventilation Technologies

The Elithis Tower is an experimental and demonstration. Elithis Tower in Dijon, France. nzeb case studies

Passive cooling effect of building features in traditional Japanese buildings

Portuguese Passive House case study: a comparison between monthly and seasonal energy performance methods

Energy consumption and thermal comfort in a passive house built in Romania

HOW TO CREATE AFFORDABLE PASSIVE HOUSE DESIGN. Andrew Lundberg Passivate

Proceedings of BS2013: 13th Conference of International Building Performance Simulation Association, Chambéry, France, August 26-28

Design Strategies and Guide lines for Tropical Coast of Pakistan, Using Climate Consultant

BUILDING SIMULATION AS AN ASSISTING TOOL IN DESIGNING AN ENERGY EFFICIENT BUILDING: A CASE STUDY

Potential of passive design strategies using the free-running temperature

Potential of ventilative cooling in German residential buildings

Built for sustainability Built for the environment Built for fuel efficiency Built for life

Evaluation of a versatile energy auditing tool

EnerPHit and EnerPHit +i

The feasibility of natural ventilation in plus energy houses in Germany

Cost-Benefit Analysis of Dwelling Retrofit Options

Achieving the nearly zero energy building concept - A study based on practical experience

Cool Roof Case Studies

Radon Levels and Indoor Air Quality in Northern Ireland Certified Passive House Buildings

Energy-Efficient Passive House using thermal mass to achieve high thermal comfort

Air Conditioning Inspections for Buildings Assessing Equipment Sizing

Active solar heating system with concrete plate heating analysed with dynamical thermal simulations

Transcription:

Dr. Wolfgang Feist Passivhaus Institut Rheinstraße 44/46 D-64283 Darmstadt www.passiv.de Passive Houses in South West Europe A quantitative investigation of some passive and active space conditioning techniques for highly energy efficient dwellings in the South West European region 2 nd, corrected edition Jürgen Schnieders 2009

Passive Houses in South West Europe Page 3 Table of Contents 1 Introduction...6 2 Summary...9 2.1 Background and Problem... 9 2.2 Method... 9 2.3 Climate... 10 2.4 Mechanical Systems... 12 2.5 Passive House Solutions... 12 2.6 Influence of Building Components... 14 2.7 Robustness... 15 2.8 Other Results... 16 3 Technical Fundamentals...19 3.1 The Passive House Principle... 19 3.1.1 Passive Houses in Central Europe...19 3.1.2 Passive Houses in Southern Europe...21 3.2 Thermal Comfort... 22 3.2.1 Comfort Scales...23 3.2.2 Heat Balance Models...23 3.2.3 Excursus: Adaptive Comfort Models...27 3.2.4 Comfort Temperatures...31 3.2.5 Inter-Individual Differences in Preferred Temperature...32 3.2.6 Humidity...34 3.2.7 Air Velocity...41 3.2.8 Local Discomfort...42 3.2.9 Summary: Comfort Criteria Used in this Study...43 3.2.10 An Index for Warm and Cold Discomfort...44 3.3 Cooling Strategies... 47 3.3.1 Passive and Hybrid Cooling...47 3.3.2 Active Cooling...48 4 Methodical Fundamentals...50 4.1 Dynamic Thermal Building Simulation... 50 4.2 Climate and Climatic Data... 51 4.2.1 Climatic Conditions in South West Europe...51 4.2.2 Meteonorm...53 4.2.3 International Weather for Energy Calculations (IWEC)...55 4.2.4 Italian Climatic Data Collection "Gianni De Giorgio" (IGDG)...57 4.2.5 Spanish Weather for Energy Calculations and Synthetic Data for Portugal...60 4.2.6 TRY Data for Southern France...62 4.2.7 Conclusions: Climatic data sets used in this study...62 4.2.8 Extreme Climatic Conditions: Summer 2003...66

Page 4 Passive Houses in South West Europe PASSIV 4.2.9 Future Climate Projections...69 4.2.10 Extreme Climatic Conditions: Heat Islands...71 4.3 Internal Heat Gains...73 4.4 Humidity Production...77 5 Reference Buildings...81 5.1 Simulation Model...81 5.2 Reference Houses...81 5.2.1 Reference Passive Houses...81 5.2.2 Reference Existing Building...121 6 Sensitivity to Building Related Parameters...126 6.1 Thermal Protection... 126 6.1.1 Energy Balance of Walls and Roof...126 6.1.2 Insulation of Exterior Walls and Roofs...133 6.1.3 Compactness...142 6.1.4 Thermal Bridges...145 6.1.5 Window Frames...148 6.2 Ventilation and Infiltration... 150 6.2.1 Airtightness...150 6.2.2 Ventilation Heat Recovery...154 6.3 Glazing and Orientation... 157 6.3.1 Glazing Type...157 6.3.2 South-Facing Glazing...167 6.3.3 Orientation...170 6.4 Dynamic Effects... 178 6.4.1 Thermal Mass...178 6.4.2 Night Ventilation...198 6.5 Humidity... 203 6.6 Ground Coupling... 211 6.6.1 Insulation of the Basement Ceiling...211 6.6.2 Insulation between Basement and Ground...215 6.7 Solar Control... 221 6.7.1 Exterior Surface Solar Absorptivity...221 6.7.2 Shading...225 6.8 Summary: Influence of Building Parameters... 232 7 Sensitivity to User Behaviour...234 7.1 Indoor Temperature Requirements... 234 7.1.1 Effects of Different Setpoints for Ideal Heating and Cooling Systems...234 7.1.2 Performance of Heating Systems with Changed Setpoints...241 7.1.3 Performance of Cooling Systems with Changed Setpoints...243 7.2 Indoor Humidity Requirements... 248 7.2.1 Lower Humidities...248 7.2.2 Higher Humidities...251 7.3 Internal Heat Gains and Humidity Production... 251

Passive Houses in South West Europe Page 5 7.4 A Tilted Window in the Bedroom... 257 7.5 Operation of Windows in Summer... 260 7.6 Operation of Shading Devices... 268 8 Extreme Climatic and Weather Conditions...271 9 Mechanical Systems...275 9.1 The Reference System: Supply Air Heating and Cooling... 275 9.2 Alternative Solutions... 276 10 Conclusions and Future Work...278 11 Glossary...280 12 References...282 A Documentation of the Example Building...300 A.1 General Description... 300 A.2 Elevation from South (left) and North (right)... 301 A.3 Floor plans... 301 A.4 Section from the East... 302 A.5 Thermal zones... 303 A.6 Building Elements... 304 A.7 Windows... 312 A.8 Ventilation... 313 A.9 Space conditioning... 314 A.10 Internal Heat Gains and Humidity Production... 314 A.11 Shading... 315 B Characteristics of the Reference Passive Houses...316 C Climate Characterisation...318 D Simulation Details...332 D.1 Heat Transfer Through the Ground... 332 D.2 Humidity Storage and Hygro-Thermal Effects... 334 D.3 Dehumidification... 336

Page 28 Passive Houses in South West Europe PASSIV [K] air-conditioned free-running 90 % acceptability 1.2 2.5 80 % acceptability 2 3.5 Fig. 3: Adaptive comfort ranges according to RP-884 for air-conditioned and free-running buildings (90 % acceptability range) Other adaptive comfort models have been proposed for free-running buildings by other authors, e.g.: T comf = 11.9 C + 0.534 T m with the ambient monthly mean air temperature T m [Auliciems 1969] T comf = 18.5 C + 0.36 T olt with the ambient long-term monthly mean air temperature T olt [Nicol 1999] T comf = 21.42 C + 0.206 T rm with a running-mean ambient air temperature T rm [McCartney 2002] T comf = 18.8 C + 0.33 T rm with a running-mean ambient air temperature T rm [Nicol 2005] In practice, adaptive models are only used for the assessment of summer comfort in buildings in which no active cooling system is operating. For this application, they have also been implemented in [ASHRAE 55] and [EN 15251]. Assuming that thermal comfort is indeed judged differently by users of air-conditioned and free-running buildings, it still appears obvious that a linear relationship of ambient temperature and comfort temperature, as assumed in various correlations of adaptive models, can only be valid within certain boundaries, and extrapolation may lead to erroneous results. An indication for the limits of validity can be found in [de Dear 1997]: the preferred temperature (i.e. the temperature at which the same fraction of subjects preferred a warmer temperature and a cooler temperature) is documented for 116 buildings with and without airconditioning. 2 of these 116 preferred temperatures are below 21 C, 3 are above 27 C. It may be concluded that temperatures above 27 C are hardly considered ideal in any climate. Interestingly, this notion is even supported by the results of the Pakistan study ([Nicol 1999]): most of the subjects started to use fans, probably in order to reduce thermal discomfort, at indoor temperatures above approximately 26 C. A si milar limit can be derived from a field study conducted by [Aggelakoudis 2005] in five office buildings in Patras, Greece. The indoor

Passive Houses in South West Europe Page 115 5.2.1.12.2 Performance overview Fig. 48: Operative temperatures and relative humidities in 11 - Naples for the reference case with supply air heating and cooling. The following useful energy demands and maximum loads result: Ideal System Real System Useful heating demand (20 C) [kwh/(m²a)] 8.44 10.02 Sensible cooling demand (26 C) [kwh/(m²a)] 3.32 4.08 Latent cooling demand (70 %) [kwh/(m²a)] 3.37 4.02 24-h average heating load [W/m²] 10.28 9.71 24-h average sensible cooling load [W/m²] 5.01 5.49 24-h average latent cooling load [W/m²] 7.25 7.51

Passive Houses in South West Europe Page 181 Higher solar gains increase the ratio of solar gains and heat losses, thus reducing the utilisation factor. The time constant of the Passive Houses becomes smaller because less thermal protection is required in the warmer climates. This effect also reduces the utilisation factor. Heating/Cooling Demand [kwh/(m²a) 20 15 10 5 0-5 -10-15 -20 Passive Houses: Effects of Thermal Mass Light Thermal Envelope From top to bottom: Heating (>0) Sensible Cooling (<0) Latent Cooling (<0) xlight light heavy xheavy 00 - Mannheim 01 - Lisbon 02 - Porto 03 - Seville 04 - Madrid 05 - Bordeaux 06 - Carpentras Heating/Cooling Demand [kwh/(m²a) 07 - Nice 08 - Torino 09 - Venice 10 - Campob. 11 - Naples 12 - Palermo 20 15 10 5 0-5 -10-15 -20 Passive Houses: Effects of Thermal Mass Heavy Thermal Envelope From top to bottom: Heating (>0) Sensible Cooling (<0) Latent Cooling (<0) xlight light heavy xheavy 00 - Mannheim 01 - Lisbon 02 - Porto 03 - Seville 04 - Madrid 05 - Bordeaux 06 - Carpentras 07 - Nice 08 - Torino 09 - Venice 10 - Campob. 11 - Naples 12 - Palermo Fig. 96: Heating and cooling demand as a function of thermal mass.

Page 234 Passive Houses in South West Europe PASSIV 7 Sensitivity to User Behaviour Dynamic building simulation inevitably has to make assumptions concerning the user behaviour. This comprises, for example, the desired temperatures and humidities, the production of internal heat gains or the patterns of window opening and blinds operation. The preceding simulations, studying the effects of changes in the building properties, were always performed for the same users. It is well-known that the behaviour and the requirements of different users vary to a large extent. The current section considers the question how the proposed Reference Passive Houses perform for different user behaviours: If the buildings are designed and built such that they maintain indoor conditions within the extended comfort range for standard user behaviour, are they still able to do so for other types of users and other comfort requirements? What will be the consequences of such different user behaviour for the energy demand? These questions relate particularly to supply air heating and cooling and to the passive cooling strategies. Therefore, instead of ideal space conditioning systems as in section 6, where the focus was on the possibilities to optimise energy demand and space conditioning loads, the real systems for heating and cooling proposed for the Reference Passive Houses in section 5.2 are considered in most cases. Generally, these systems will consist of a supply air heating and cooling with some support by night ventilation and blinds operation; depending on the location, purely passive cooling strategies may also be applied (cf. also Appendix B for an overview). 7.1 Indoor Temperature Requirements In section 3.2.5 it was already discussed that there are large differences in the preferred temperature between individuals. The present section investigates the effects of changes in the temperature setpoints: how is the energy demand affected, and to what extent are heating or cooling systems with limited power able to respond to increased comfort requirements? 7.1.1 Effects of Different Setpoints for Ideal Heating and Cooling Systems For central European conditions, it is well known from both theory and experimental results that the heating demand of Passive Houses may vary by a factor of 4 or more, depending on the average indoor temperature during the heating period (cf. e.g. [Schnieders 1998], [Schnieders 2001]). Possible crossflows of heat between dwelling units may contribute to these differences. The relative differences are higher than in conventional buildings, whereas the absolute additional heating demand increases slowlier than in conventional buildings, due to the lower specific heat loss. Fig. 136 shows the effects of changes in the heating setpoint for the Reference Passive Houses in all locations, i.e. for setpoints from 18 to 24 C, assuming an ideal heating system. The setpoints for secondary temperature control mechanisms, namely control of the heat recovery bypass, beginning of night ventilation and closing of shading devices, were shifted by the same amount as the heating setpoint. It can be seen that the heating demand increases strongly with the indoor temperature, showing a small nonlinearity that is believed to be mainly due to a longer heating period at higher setpoints.