Sensor Holder for Dexis Sensors

Similar documents
OPERATOR S INSTRUCTIONS

BIOSAFETY LEVEL 2 PROTOCOLS BIOPROCESS OPTIMIZATION LABORATORY - POULIOT BUILDING, ROOM 1541 ALAIN GARNIER JUNE 2007, LAVAL UNIVERSITY

Entellus Medical Sinuscope INSTRUCTIONS FOR USE

Gynecology Product Catalog. TRUCLEAR System. Comprehensive care, total solutions

RapidPort EZ Port Applier DIRECTIONS FOR USE (DFU)

Secure Aseptic connections outside the cleanroom

Secure Aseptic CONNECTIONS. outside. the cleanroom

ASAHI Masters PARKWAY SOFT. ASAHI Masters PARKWAY HF

The frame elements, accessories and additional elements are maintenance-free!

General Features of Cantilever Racking

CARE SERVICE USER GUIDE. Sonicision System

BoSS Climalite Camera and lighting tower

Fast. Easy to use. Secure traceability.

INNOVATIVE PLASTIC CONTAINERS

(01) Thermo Bond Buildings Military Service Shelter: DOG KENNEL OPERATING AND SETUP MANUAL MSS-RP-1-20P

FIXED CEILING COLUMN. Installation Manual FIXED CEILING COLUMN

BESTMOVE STANDING TRANSFER AID

3M Tegaderm PICC/CVC Securement Device + I.V. Advanced Securement Dressing Product Description

Build With VICTUS. Build Your Patient Offerings. Build Your Premium Practice.

Zip GlobalPlus Water Filters

LIFT-O-FLEX EOT (Manual Rotate & LIFTER USER MANUAL. Electric Expander) We re here for you. PLACE SERIAL NUMBER LABEL HERE. Have Questions?

DR-6/DT-6 MEDIUM VOLTAGE RING MAIN UNIT. Lifting & Transport Instructions MEDIUM VOLTAGE SWITCHGEAR, BUILT TO LAST

ON-SITE ANALYSIS PIPELINE FLUIDS BACTERIA KIT

GETINGE 8666/8668 WASHER-DISINFECTOR. Always with you

1. Introduction Norms and certifications General information ID Data Load moved from the post to the anchorage point 4

MODEL 185R Kontrol-Karrier Operator s Manual for Morse Kontrol-Karrier

Installation and Operating Environment Guidelines

LIFE SCIENCE Isolation, Transfer, and Containment Solutions

Whitening Lamp. Instructions for use. flaesh.com

REF DOC # STANDARD IMAGING, INC Murphy Drive Middleton, WI TEL TEL FAX

ZX70 & ZX80 SERIES PRECISION DECADE RESISTANCE BOX

Operator s Manual for Morse Mobile-Karrier for 55-Gallon Plastic or Steel Drum

CORNER ELEMENTS CENTRE SUPPORT ACCESSORY BAG PROJECTION SCREEN BAG. 4 pieces- basic frame 52x52 cm (fig.: including SET UP SUPPORT,optional)

Uncompromised accuracy in neuroimaging and treatment

BESTMOVE STANDING TRANSFER AID

Bone Marrow Concentration. For customized cellular concentrations of platelet-rich plasma from bone marrow aspirate

Snap TM 500 Short Feed

Needle Loading. Seed Sterilization. Shielding. Seed Handling. SeedVac Seed Slider. Seed Sterilization and Sorting Tray Seed Sterilization Pill Box

510(K) Summary. Monroe Township, NJ Girgis Scope Video 200 Doubled Bladed Laryngoscope

Leksell. Vantage Stereotactic System. Advancing stereotactic neurosurgery

dependable sample protection Trusted reliability Worldwide support Environmental stability Innovative design

PARKAY LAMINATE FLOORING (UNILIN DROP) Installation Instructions

Alto CareChair Commode Chair ISO classification Stainless steel, aluminium, composite plastic Date of manufacture 12.02

Scientific Production Company Doza GAMMA RAY IRRADIATION UNIT UPG-P FOR CALIBRATION SERVICES. User Manual FVKM RE

Guidelines for sampling and maintenance of the QualiTru Side Mount Truck Sampler

STANDARDS LAMINATE FLOORING (UNILIN A2A) Installation Instructions

Contact. (984) Distribution Drive, #E Morrisville, NC 27560

Movibloc Mobile Shelving / Mobile Lockers

APPLICATION PACKET. Professional Use Waiver

Optima Dipper Systems Product Overview

Sirona competency in hygiene DAC PROFESSIONAL. Hygiene systems. Vacuum autoclave class B to satisfy the most demanding requirements

Operator s Manual for Morse Heavy-Duty Kontrol-Karrier with 3-Piece Drum Holder

SAWS. S - Series - Sliding Table Panel Saws

Tower ASSEMBLY GUIDE

model QRI User manual

The Premium-Plus-Class Now even better. Up to 9 kg of instruments!

A-0312 ASSEMBLY GUIDE

Has anyone really thought about the requirements for drilling living human bone tissue until now? One simple solution.

Span 400 Instruction Manual

MEDIUM VOLTAGE SWITCHGEAR THE MODULAR CONCEPT

General Guidelines. Instructions for Part # WP Safety. It is the user s responsibility to read and follow all instructions.

PUSH-BUTTON SERIES SELF-CLEANING LIP LUG DESIGN CLOSED BUMPER BLOCKS

Operator s Manual for Morse Kontrol-Karrier with Spark Resistant Parts and Air Power Tilt

Infrared Digital Scouting Camera

ASSEMBLY MANUAL FOR PROLYTE STAGE DEX. Read this manual carefully and understand all of it s contents before you assemble the Stage DEX.

AP5K-C Precision AC Double-Pulse Spot Welding Machine User s Manual Shenzhen Will-Best Electronics Co., Ltd

Smart Distribution Panel with ATS Unpacking Instructions

Architect and Engineer Specifications

HCP-7000 Opreator s Manual 1. Operator s Manual.

DJ Switch 10F V2 ORDERCODE 50365

Installation of Vacuklav 24-B. 1 General features. Figure 1

Directions for use. Instructions, warranty and cleaning for Miltex loupe optics and frame

MODEL: ASCEND SIT/STAND COMMAND CENTER CONSOLES

C Series Mechanical Pit Levelers. P.O. Box 338 Spring Hill, Tennessee fax:

Model 5200 Cargo Lift Installation and Operation Manual

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

Background Statement for SEMI Draft Document #5295 New Standard: Specification for Coin-Stack Type Tape Frame Shipping Container for 300 mm Wafer

ENGLISH Compact Half Coupler 50 mm, SWL: 50 kg

CYTOPERM 2 CO 2 - AND CO 2

Pallet Jack 4,400 Lbs Capacity Model #31001

Silent Gliss. Room Divider/Cubicle/ Shower Rail Systems

loqelmelp=p=l=p=`ééü loqelmelp=p=ap=l=p=`ééü=ïáíü=ìéöê~çé=háí

Maximum performance and durability TCE 443x-24 / 447x

PRODUCT CATALOGUE. for gke Steri-Record and gke Clean-Record Chemical indicators, PCDs and accessories for cleaning and sterilization

CH-200M. Ceiling Type X-ray Tube Support GENERAL FEATURES PD

Maxwell RSC Buffy Coat DNA Kit

Laser Technology. Laser Technology. Units & Tips. BIOLASE BIOLASE I-LASE wireless US$ 3, CATALOG oct/09/2018 1

ISSUED: OCT. 11, 2005 REVISED: JAN. 1, 2007 HOSHIZAKI REFRIGERATED GLASS MERCHANDISER KD-90D MODEL INSTRUCTION MANUAL

Volume MMF POS. Instruction Manual /User Guide

SECTION REFRIGERATED AUTOMATIC SAMPLER

Family Secrets. Part 4 Testing for the HD Gene

SOLUTIONS WITH DUPONT CORIAN FUTRUS CASEWORK SYSTEMS

CHEMICAL/BACTERIA KIT - FLUIDS

Lubrication Labeling and Identification

Advantage Basket Stretcher

NeuroPort Array PN 4382, 4383, 6248, and 6249 Instructions for Use

MODEL: SLAT-WALL COMMAND CENTER CONSOLES

KS EXTENSIONS FOR CLEAN ROOMS

and Shield with Vertical Needle Holder REF 90072

July P Wide Format Stacker User Guide

Transcription:

Sensor Holder for Dexis Sensors TM

Holder TrollByte Rayzor 510 15300510 Accessories TrollBag Rayzor 510 13190510 TrollByte Rayzor Tab 15300020 TrollByte Rayzor Arm 15300010 Bite block 1519002003 Aiming ring 1519001001

Attachment and removal Page 4-6 Arm Version Aiming Bitewings Anterior PA Posterior PA Page 7-8 Page 9-10 Page 11 Page 12 Tab Version Bitewings Anterior/Posterior PA Page 13 Page 14

Put the holder on the sensor The end with the slot must face the cord. The sensor holder is fully autoclavable. Configure the sterilization program in accordance with the autoclave manufacturer s instructions. Maximum temperature 273ºF (134ºC). Please note: The slot extension on the side should be withdrawn during autoclaving. Put the TrollBag Rayzor 510 sensor cover on 4

Attachment of the arm/tab The arm/tab contains small parts. Please check that it is unbroken. Do not use an arm, tab or bag that is broken. When attatching the arm/tab, it is very important to be careful when you ease the heel in (img. 1-3 below). Excessive force can puncture the sensor cover. Please note: The door lock must be open when you attach the holder arm/tab. Toe Heel 1. Insert the toe. 2. Press forward. 3. Ease the heel in and release. 4. Press to close the door lock. 5

Removal of the arm/tab NOTE: This procedure is shown without the sensor cover for detail. 1. 2. Press to open the door. 3. Press forward. 4. Ease the heel out. The arm, tab and the sensor cover are disposables, single use only. When removing the arm/tab, it is very important to be careful when you lift the heel. Excessive force can puncture the sensor cover. 6

Aiming The indicator pin shows the center of the sensor. X-ray tube The indicator pin is removable. 7

Aiming ring Image and ring position Anterior PA Posterior PA Bitewing Posterior PA Anterior PA Aiming ring attachment Dots facing the sensor. The aiming ring is fully autoclavable. Configure the sterilization program in accordance with the autoclave manufacturer s instructions. Maximum temperature 273ºF (134ºC). 8

Horizontal Bitewing Position for the ring, dots facing the sensor. 9

Vertical Bitewing Position for the ring, dots facing the sensor. 10

Anterior PA Position for the ring, dots facing the sensor. Use the bite block for all anterior periapical images. The bite block works as an extension of the biteplane and it allows you to place sensor as posterior as possible while maintaining support from the incisal edges of the front teeth. The bite block is fully autoclavable. Configure the sterilization program in accordance with the autoclave manufacturer s instructions. Maximum temperature 273ºF (134ºC). 11

Posterior PA Pull out the appropriate slot, for upper right/lower left or upper left/lower right quadrandts. Position for the ring, dots facing the sensor. 12

Tab Version Horizontal Bitewing Vertical Bitewing 13

Posterior PA Pull out the appropriate slot for upper right/lower left or upper left/lower right quadrandts. Anterior PA 14

To make excellent x-rays please note: Position the sensor where most space excist, normally the mid-palatal area. The TrollByte Rayzor gives you the angle and position of the sensor. How you use that information to acquire perfect images is up to you as a skilled dentist. You can find more information and videos at www.trolldental.com US Patent 7,140,770 B2 France Patent 1537453 Great Britain Patent 1537453 Germany Patent 60319389.7 Japan Patent 4464820 Sweden Patent 0202371-1 is committed and dedicated to the dentist and patient. We believe that TrollDental providing dentists with intelligent quality tools improves the ability of the dentist to more precisely diagnose and treat patients in a gentle way. Our goal is to provide tools that will ensure the success of the dentist and health of the patient. Trollhätteplast AB Box 900 S-461 29 Trollhättan SWEDEN

TrollByte Rayzor shall only be used as a holder for dental x-ray with Dexis digital sensor. The manufacturer and its dealers are not liable for any other use of the product. Always use a sensor cover to protect the sensor while taking x-rays. Clean prior to first use. TrollByte Rayzor can be cleaned by wiping it down with alcohol, washing it in a dishwasher/disinfector, or autoclave. Reuse without disinfection will lead to contamination and possible spread of infection. Store at room temperature, protected from dust and humidity. Do not expose to direct sunlight. Autoclave procedure Warranty TrollByte Rayzor is autoclavable. Configure the sterilization program in accordance with the autoclave manufacturer s instructions. Maximum temperature than 134ºC (273ºF). Please note that the retractable slots should be withdrawn during autoclaving. Place in the middle of the autoclave, not against the autoclave s walls or heating element. Warning: If the holder is exposed to pressure or weight exerted by other objects during autoclaving, it may deform. Please note: Any method of sterilization will shorten the life span of plastic parts. TrollByte Rayzor is manufactured using carefully selected plastic raw materials in order to achieve the product s unique characteristics. However, all plastic products have a limited service lifetime, and should be replaced at regular intervals. All types of cleaning reduce the product s service lifetime. The product should be replaced when its functioning and/or performance no longer satisfies the specifications in this manual. The manufacturer guarantees that the product will function as described in these instructions for 1 year after first use or a maximum of 75 autoclave cycles. Dexis is a trademark of Dexis, LLC of Hatfield, PA TrollByte Rayzor 510 15300510 Trollhätteplast AB Installatörvägen 9 461 37 Trollhättan Sweden +46 520 48 90 50 www.trolldental.com 2014-10-01 15300510/001