U.V resistance UL Sunlight Resistance. Flame retardant IEC

Similar documents
MEDIUM VOLTAGE XLPE INSULATED POWER CABLES [6.35/11kV Copper XLPE Three-Core HDPE Sheathed]

XLPE MATERIAL NATIONAL CABLES INDUSTRY XLPE INSULATED MEDIUM VOLTAGE CABLES

Specification FOR. 12.7/22KV AL-CV/WS 12.7/22KV Aluminum Conductor XLPE Insulated Copper Wire Screened PVC Sheathed Power Cable.

INTERNATIONAL STANDARD

NPS/002/020 Technical Specification for 11 & 20kV Power Cables

26/35kV Copper XLPE Insulation Electric Cable

DMRC ELECTRICAL STANDARDS & DESIGN WING (DESDW)

This document is a preview generated by EVS

INTERNATIONAL STANDARD

NPS/002/023 Technical Specification for 132kV Power Cables.

0.6/1 kv LOW VOLTAGE CONTROL CABLES. Conductors. Insulation. Assembly. Standard Colour Code. Armour (Optional) Screening (Optional) Outer Sheath

WIND TURBINES DEDICATED CABLES LV AND MV VOLTAGE RUBBER CABLES

40/69 kv to 127/220 kv XLPE

137-1: 2015 CEB SPECIFICATION. XLPE INSULATED SINGLE CORE UNDERGROUND CABLES OF 11 kv RATED VOLTAGE

11-SDMS-01 REV. 02 SPECIFICATIONS FOR LOW VOLTAGE POWER AND CONTROL CABLES

SPECIFICATION FOR THHN/THWN-2/THW/THWN/TW ARROW ROUTE, FONTANA CA

138-1: 2015 CEB SPECIFICATION. AERIAL BUNDLE CONDUCTORS - 33 kv (95mm 2 and 150mm 2 )

CONSULTATIONS TECHNICAL GUIDELINE. HVDC extruded cable

EHV XLPE CABLES CDCC LINE

Accreditation No: LAB 041. Electrical Measurement & Test Laboratory (EMTL), PCSIR Labs. Complex, Lahore Pakistan.

AMENDMENT OF MALAYSIAN STANDARD MALAYSIAN STANDARD MS :2009

10-SDMS-02 SPECIFICATIONS FOR BARE COPPER CONDUCTORS

11-SDMS-01 REV. 03 ( )

STANDARD FOR EXTRUDED INSULATION POWER CABLES RATED ABOVE 46 THROUGH 345 KV. Approved by AMERICAN NATIONAL STANDARDS INSTITUTE.

NUCLEAR POWER CORPORATION OF INDIA LTD. (A GOVT. OF INDIA ENTERPRISE) SPECIFICATION NO.PB-E-542/REV. No.0

MATERIAL STANDARD FOR CABLES AND WIRES

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

TYPE TEST REPORT OF 11 KV 3 x 240 mm² CU/XLPE/SWA/PVC CABLE. Kinectrics International Inc. Report No.: K RC-0001-R00.

PV Solar Wiring Solutions

DRAFT TANZANIA STANDARD. Part 7: Underground Power Cables for rated voltages 0.6kV/1kV (Um 1.2kV)

L1-CHE-SPE-171 TECHNICAL SPECIFICATION FOR ELECTRIC CABLE

TECHNICAL SPECIFICATION FOR L. T. XLPE POWER CABLE

NPS/002/018 Technical Specification for Pilot, Control and Telephone Cables

Factors Affecting Current Ratings for Underground and Air Cables

Conductor Shield A combination of semi-conducting tape and extruded thermosetting semi-conducting material meeting UL 1309, IEEE 1580 and UL1072.

Superastic Flex Cable 450 / 750V Exceeds all the specifications in its category.

SECTION 7.3 TECHNICAL SPECIFICATION OF POWER CABLES & CONDUCTOR

YKY, YKY-żo 0,6/1kV PN-93/E-90401, PN-HD-603 S1, IEC

WIRES, CABLES AND CORDS

IEEE 1580 Type P MOR Polyrad XT-125 Multi Conductor

TECHNICAL SPECIFICATION FOR 1.1KV XLPE POWER CABLE SECTION-1

NORMAS DE REFERENCIA AEIC CS 1: ASTM B

Cables ELE E L CT E C R T R IC I C A A L L

SOUTH CAROLINA ELECTRIC COOPERATIVES' PRIMARY UNDERGROUND POWER CABLE SPECIFICATION

--> Buy True-PDF --> Auto-delivered in 0~10 minutes. TB/T Translated English of Chinese Standard: TB/T1484.

ISO 6722 INTERNATIONAL STANDARD. Road vehicles 60 V and 600 V single-core cables Dimensions, test methods and requirements

DEVELOPMENT OF HIGH VOLTAGE EXTRUDED CABLES: THE ITALIAN EXPERIENCE

NEMA Standards Publication No. WC ICEA Publication No. S

SECTION MEDIUM-VOLTAGE CABLES PART 1 GENERAL

THE PATHWAY TO POWER HIGH AND EXTRA HIGH VOLTAGE CABLES

DATA SHEET Single Core 2HR Fire Rated Cable

ENERGY PROTOLON(SMK) LWL. (N)TSKCGEWOEU Medium Voltage Reeling Cable with integrated Fibre Optics

Armoured Instrumentation Cables to BS7917

Electric cables. CRANES APPENDIX

TI 20 PVC TI 20 INSULATED TELEPHONE WIRE

15 kv EPR Insulated, Jacketed, URD Cable

Technical Specification for Single Core 19/33kV Copper / TR-XLPE Underground Cable

Comparison of BS 5308, PAS 5308 and BS EN

Type 1 Machine Cable. Oxygen free tinned annealed copper wire interwoven with high tensile poly-yarn

The Contractor shall furnish and install all shielded power cable suitable for use on this project.

SECTION 07. TECHNICAL SPECIFICATIONS OF 11 KV XLPE CU CABLE (1x500 mm 2 )

H-FLEX CABLES 10/2017

SYRIAN ARAB REPUBLIC MINISTRY OF ELECTRICITY PUBLIC ESTABLISHMENT FOR DISTRIBUTION The ELECTRICITY (PEDE) TENDER DOCUMENTS FOR

MGVCL/MM/ 3Cx240 mm 2 XLPE Cables/2077 TECHNICAL SPECIFICATION FOR 11 KV XLPE POWER CABLE (CROSS LINKED POLYTHELENE DRY GAS CURED) SECTION I

SPECIFICATIONS FOR Gas-to-Cable termination

SUBMERSIBLE. Electric cables

NPS/002/017 Technical Specification for 66 kv and 132 kv Cable Accessories

BLACK EPR INSULATED MEDIUM VOLTAGE CABLES. Ronald F. Frank, Eng. Consultant

XLPE CABLE (11KV - Aluminium)

OFFSHORE CABLES NEK 606 : with FIREBAR the TOTAL SAFETY fire and water resistant cable

America s Wire Company

Termco Heatshrink.

Four Core, Copper Conductor Extruded Cross - Linked Polyethylene (XLPE) Insulated Power Cable

DXL 4233 Insulation for Low Voltage Power Cables

MANUFACTURER'S QUALITY ASSURANCE PLAN (QAP - Instrumentation cables)

Tele-Fonika Cable Americas

ANSI/NEMA WC ICEA S Power Cables Rated 2000 Volts or Less for the Distribution of Electrical Energy

Technical Specification for Substation 11kV and 22kV Single Core Underground Cable

Instrumentation Cables

TECHNICAL SPECIFICATIONS FOR CROSS LINKED POLYETHYLENE INSULATED 3 CORE llkv CABLES

SCHEDULE ' A ' TECHNICAL SPECIFICATION FOR L.T.PVC POWER AND CONTROL CABLES FOR DISTRIBUTION NETWORK IN MAHARASHTRA

Technical Specification for PVC Insulated Low Voltage Neutral Screened Copper Cable

SafeX110 Single Core Flexible Tinned Copper Cable

Profile No.: 4 NIC Code: ELECTRICAL CABLES (SINGLE AND MULTICORE)

SPECIFICATION FOR FRLS POWER CABLES

Construction guideline

STANDARD SPECIFICATION FOR SIGNAL CABLE. A. This Specification provides for single and multi-conductor insulated and jacketed cable for

ISO INTERNATIONAL STANDARD

PVC Insulating Tape. Electrical Tapes

Low Voltage Live Pot End Kits

Electrical Conductors Line

Standard of Practice - Campus Electrical Distribution System

THE PERFORMANCE OF XLPE WATER TREE RESISTANT INSULATION SYSTEMS AGAINST THE REQUIREMENTS OF DIN VDE /A3

15~35KV Termination Kit

RESIN FILLING TYPE JOINTING KITS FOR LOW VOLTAGE UNDERGROUND CABLES

Available in 0.75 to 16.0 sq mm. Red, Yellow, Blue, Black, White, Gray and Green (for earthing) Specification IS 694:1990

Clark Public Utilities

1.2 REFERENCES.1 CSA C22.2 No.0.3, Test Methods for Electrical Wires and Cables.

Engineering Recommendation G81- Part 2: Materials Specification

Accelerated Aging Tests for MV Cables

Transcription:

Cable for underground power distribution and subtransmission. Description Application Underground power distribution and subtransmission. As transformer feeders in substations. In power plants, industrial and operation installations, in residential areas and mining installations, in dry or wet locations. Construction 1. : Copper, class 2. 2. Inner semi-conductor: Extruded. 3. Insulation: linked polyethylene XLPE. 4. External semi-conductor: Extruded strippable. These last three components extruded CV (continuous vulcanization) triple extrusion. 5. Screen: Copper tapes. 6. Outer : Compound polyvinyl chloride PVC. Main characteristics of 90ºC for normal operation, 130 C for emergency overload and 250 C for short circuit conditions. Excellent properties against heat aging. to abrasion, moisture and sunlight. Adequate resistance to greases and oils.. Gauge: From 50 mm² up to 630 mm². Marking: INDECO S.A. Section Packing: Non returnable wooden reels. Colour: Insulation: Natural. Outer : Red. Standards International IEC 60228; ; IEC 60502-2; IEC 60811-1-1; IEC 60811-1-2; IEC 60811-1-3; IEC 60811-1-4; IEC 60811-2-1; IEC 60811-3-1; IEC 60811-3-2 National NTP-IEC 60228; NTP- IEC 60502-2; UL 1581 National standards Version 1.4 Generated 4/18/17 - http://www.nexans.pe Page 1 / 5

NTP-IEC 60228: s of insulated cables. NTP-IEC 60502-2: Power cables with extruded and their accessories for rated voltages from 6 kv up to 30 kv. International standards IEC 60228: s of insulated cables. : Test for vertical flame propagation for a single insulated wire or cable. IEC 60502-2: Power cables with extruded and their accessories for rated voltages from 6 kv up to 30 kv. IEC 60811-1-1: Measurement of thickness and overall dimensions - Test for determining the mechanical properties. IEC 60811-1-2: Thermal ageing methods. IEC 60811-1-3: Water absorption tests - Shrinkage test. IEC 60811-1-4: Tests at low. IEC 60811-2-1: Ozone resistance, hot set and mineral oil immersion tests. IEC 60811-3-1: Pressure test at high - Tests for resistance to cracking. IEC 60811-3-2: Loss of mass test - Thermal stability test. UL 1581 Section 1200 (Sunlight resistance): Reference standard for electrical, cables, and flexible cords - Carbon-Arc and Xenon-Arc Tests- Sunlight resistance. Characteristics Construction characteristics material Copper Material of the inner semi-conductor Extruded Insulating material XLPE Material of the external semi-conductor Extruded strippable Screen Copper tape, helically Outer PVC Electrical characteristics Usage characteristics Overload maximum core 250 C Version 1.4 Generated 4/18/17 - http://www.nexans.pe Page 2 / 5

Usage characteristics Short-circuit max. conductor 130 C Dimensional Data Total nb diam. weight [kg/km] 50 19 8.01 23.67 25.4 28.1 1074 70 19 9.78 25.43 26.8 30.3 1352 95 19 11.55 27.2 28.6 32 1655 120 37 13.0 28.65 30.0 33.7 1942 150 37 14.3 29.96 31.7 34.8 2190 185 37 16.16 31.81 33.2 37.1 2664 240 37 18.51 34.16 35.5 39.5 3274 300 37 20.54 36.2 37.9 41.3 3847 400 61 23.51 39.16 40.5 44.7 4802 500 61 26.45 42.11 43.9 47.7 5826 630 61 29.97 45.63 47.4 51.6 7304 Electrical Data - I Max. DC Resist. Cond. 20 C A.C. resist. at - flat formation A.C. cond. resist. - trefoil Phase reactance 60 Hz - flat formation Phase reactance 60 Hz - trefoil formation 50 0.387 0.4937 0.4938 0.2354 0.1657 70 0.268 0.3421 0.3422 0.2281 0.1584 95 0.193 0.2466 0.2468 0.2197 0.15 120 0.153 0.1958 0.1961 0.2137 0.144 150 0.124 0.159 0.1594 0.2078 0.1381 185 0.0991 0.1275 0.1281 0.2045 0.1348 240 0.0754 0.0976 0.0985 0.199 0.1293 300 0.0601 0.0785 0.0797 0.193 0.124 400 0.047 0.0624 0.064 0.1899 0.1202 500 0.0366 0.05 0.052 0.1852 0.1156 630 0.0283 0.04 0.0427 0.1817 0.1121 Version 1.4 Generated 4/18/17 - http://www.nexans.pe Page 3 / 5

Electrical Data - II Perm. current rating buried 20 C - flat formation Perm. current rating buried 20 C - trefoil formation Perm. current rating in air 30 C - flat formation current rating in air 30 C - trefoil 50 203 196 286 238 70 246 239 356 296 95 293 285 434 361 120 332 323 500 417 150 366 361 559 473 185 410 406 637 543 240 470 469 745 641 300 524 526 846 735 400 572 590 938 845 500 631 652 1080 945 630 695 725 1221 1079 Product List =Make to order, =In stock Nexans ref. Name (mm²) P00015697 P00000718-1 50 mm2 70 mm2 95 mm2 120 mm2 150 mm2 185 mm2 240 mm2 Total nb diam. weight (kg/ km) 50 19 8.01 23.67 25.4 28.1 1074 70 19 9.78 25.43 26.8 30.3 1352 95 19 11.55 27.2 28.6 32 1655 120 37 13.0 28.65 30.0 33.7 1942 150 37 14.3 29.96 31.7 34.8 2190 185 37 16.16 31.81 33.2 37.1 2664 240 37 18.51 34.16 35.5 39.5 3274 = Make to order, = In stock Version 1.4 Generated 4/18/17 - http://www.nexans.pe Page 4 / 5

Nexans ref. Name (mm²) P00004297 P00008096 P00015698 300 mm2 400 mm2 500 mm2 630 mm2 Total nb diam. weight (kg/ km) 300 37 20.54 36.2 37.9 41.3 3847 400 61 23.51 39.16 40.5 44.7 4802 500 61 26.45 42.11 43.9 47.7 5826 630 61 29.97 45.63 47.4 51.6 7304 = Make to order, = In stock Calculation of Current Condition Single-core M.V. CALCULATION OF CURRENT CONDITION BASED ON NTP-IEC 60502-2 Annex B Maximum conductor : 90 C. Ambient air : 30 C. Ground : 20 C. Depth of laying : 0.8 m. Thermal resistivity of soil : 1.5 K.m/W. Screens bonded at both ends. Version 1.4 Generated 4/18/17 - http://www.nexans.pe Page 5 / 5