ISO-9001 Certified ISO-14000 Certified ISO-17025 Certified ADVANTECH CO., LTD. QA Test Report VITA-350 (Product Reliability Test) Report No : 07S092A1 Report Date : January 10, 2008 Issue Stamp Charles Chang Manager of QA Department Jeff Yang Approval Knight Hu Test Engineer
VITA-350 Table of Contents Report No.07S092A1 1. History list.. 2 2. Test item list 3 3. Product specification entry 4 4. Product configuration photo.. 5 5. High temperature operation test 9 6. Low temperature operation test. 11 7. Power ON/OFF test... 13 8. Cold Start Test. 15 9. Humidity test.. 19 10. High temperature/humidity storage test 21 11. Low temperature storage test.... 24 12. Thermal profile test. 27 13. Random vibration test. 30 14. Sine vibration test 36 15. Package vibration test. 41 16. Package drop test... 46 17. Shock test. 53 1
VITA-350 History List Report No.07S092A1 Ver. Description Remark A0 The VITA-350 test report A1 Update test standard description of random vibration Page 30 test with typing error. 2
VITA-350 Test Item List Report No.07S092A1 Num. Test item Result Remark 1 High temperature operation test Passed 2 Low temperature operation test Passed 3 Power ON/OFF test Passed 4 Cold Start Test Passed 5 Humidity test Passed 6 High temperature/humidity storage test Passed 7 Low temperature storage test Passed 8 Thermal profile test Passed 9 Random vibration test Passed 10 Sine vibration test Passed 11 Package vibration test Passed 12 Package drop test Passed 13 Shock test Passed 3
VITA-350 Product Spec Entry Report No.07S092A1 Num Item Specification 1 I/O port External I/O 1 x Serial Port: RS-232 interface 1 x Reset Button 1 x Phoenix Type of Power Input Connector 1 x Phoenix Type of Digital I/O Connector Programmable Digital I/O 2 GPRS Module Siemens Power Modes Sleep mode at DRX = 2 DRX = 5 DRX = 9 IDLE mode at DRX = 2 GSM 850 1)4) EGSM 900 1)4) GSM 1800/1900 2)4) Data mode GPRS, (4RX, 1TX) GSM 850 1)4) EGSM 900 1)4) GSM 1800/1900 2)4) 3 GPS Specifications 16 Channel ANTARIS 4 Positioning Engine Supports Various Serial Protocols (NEMA, UBX, & RTCM) Supports Active Antenna Short Antenna and Open Circuit Power Brown-out Protection: No External Reset Hardware Needed Accuracy: Position 2.5m CEP 5.0m SEP Position DGPS/SBAS2 2.0m CEP 3.0m SEP 4 GSM/GPRS Specifications of Siemens MC55 Module 5 Weight 100g 6 Power supply 9~35 V DC Tri-band MC55 EGSM900 /GSM1800/1900 GPRS Multi-slot Class 10 GPRS Mobile Station Class B Download: Max. 85.6 Kbps Uplink: Max. 42.8 Kbps Coding scheme CS1-4 Internet Service TCP, UDP, HTTP, FTP, SMTP, POP3 4
VITA-350 Product Configuration Photo Report No.07S092A1 Photo I: VITA-350 right-front side view 5
VITA-350 Product Configuration Photo Report No.07S092A1 Photo II: VITA-350 left-rear side view 6
VITA-350 Product Configuration Photo Report No.07S092A1 Photo III: VITA-350 structure photo I 7
VITA-350 Product Configuration Photo Report No.07S092A1 Photo IV: VITA-350 structure photo II 8
VITA-350 High Temp. Operation Test Report No.07S092A1 Test Date : September 7, 2007 ~ September 8, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : 70 2. Test Times : 24Hrs 3. Test Software : Receive GPRS and GPS signal from satellite and basic station 4. Test Environment Curve : Temp 70 25 time Hrs 0:0 2:00 26:00 28:00 9
VITA-350 High Temp. Operation Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL4+- 150 Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets high temperature operation test. 10
VITA-350 Low Temp. Operation Test Report No.07S092A1 Test Date : September 11, 2007 ~ September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -20 2. Test Times : 24Hrs 3. Test Software : Receive GPRS and GPS signal from satellite and basic station 4. Test Environment Curve : Temp 25-20 Time Hrs 0:0 1:30 25:30 27:00 11
VITA-350 Low Temp. Operation Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL4+- 150 Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1.All system functions must be checked with appropriate testing programs and should pass the inspection. 2.The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets low temperature operation test. 12
VITA-350 Humidity Test Report No. 07S092A1 Test Date : September 7, 2007 ~ September 9, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures Test Ca : Damp Heat steady state Test Test Condition : 1. Test Temperature : 40 2. Test Humidity : 95% 3. Test Times : 48Hrs 4. Test Software : Receive GPRS and GPS signal from satellite and basic station 5. Test Environment Curve : Humidity % Temp 95% 40 25 50% Time Hrs 0:00 1:00 49:00 50:00 13
VITA-350 Humidity Test Report No. 07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL4+- 150 Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button and cover slot should work properly without any interference. 2. All screws should be tightened up appropriately. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets humidity test. 14
VITA-350 Power ON/OFF Test ReportNo.07S092A1 Test Date : September 8, 2007 ~ September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition : Condition I : 1. Test Temperature : -20 2. Test Times : 72 Hrs Step: A. System power on, record the count number then system power off. B. After 2 minutes, system power on again. C. Recycle step A& B for 1000 times. 3. Number of test : 1000 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve: Temp 25 Power ON 1 2 998 999 1000 Times iiiiiiiiiiii -20 Power OFF Time Hrs 0:00 72:00 15
VITA-350 Power ON/OFF Test ReportNo.07S092A1 Condition II : 1. Test Temperature : 70 2. Test Times : 72Hrs Step: A. System power on, record the count number then system power off. B. After 2 minutes, system power on again. C. Recycle step A& B for 1000 times. 3. Number of test : 1000 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve: Temp 70 Power ON 1 2 998 999 1000 Times iiiiiiiiiiii 25 Power OFF Time Hrs 0:00 72:00 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp Model : THS-D4S-100 Date of Calibration : 01/24/2007 16
VITA-350 Power ON/OFF Test ReportNo.07S092A1 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Test Data : Test temperature Test times Test Result -20 1000 times 1000 times pass 70 1000 times 1000 times pass Performance Criteria : Electronic function check: 1. It could not failure any time during 1000 times testing. 2. All system functions must be checked with appropriate testing programs and should pass the inspection. 3. The system should not have degradation in its performance. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 17
VITA-350 Power ON/OFF Test ReportNo.07S092A1 Test Result : There is no failure time during 1000 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets power on/off test. 18
VITA-350 Cold Start Test ReportNo.07S092A1 Test Date : September 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -20 2. Test Times : 8Hrs Step: A. System power off 4 hours. B. System power on, then 2 minutes later, system power off. C. After 10 minutes, system power on again. D. Two minutes later, system power off again. E. Recycle step C& D for 20 times. 3. Number of test : 20 times 4. Test Software : VITA-350 power on connect to terminal PC, ensure function is worked. 5. Test Environment Curve : Temp 25 Power ON 1 2 18 19 20 Times iiii -20 Power OFF Time Hrs 0:0 1:00 5:0 10min 9:00 10:00 12:00 19
VITA-350 Cold Start Test ReportNo.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K. SON. INS. Tech. Corp. Model : THS-DL4+- 150 Date of Calibration : 05/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. 3. It could not failure any time during 20 times testing. Test Result : There is no failure time during 20 times testing. There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets cold start test. 20
VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Date : September 14, 2007 ~ September 15,2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-3 Testing procedures Test Ca : Damp heat steady state test Test Condition : 1. Test Temperature : 60 2. Test Humidity : 95% 3. Test Times : 24Hrs 4. Test Environment Curve : Humidity % Temp 95% 60 25 50% Time Hrs 0:00 1:00 25:00 26:00 21
VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K.SON. CO. LTD. Model : THS-DL4+/-150 Date of Calibration : 5/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 22
VITA-350 High temp./humi. Storage test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets high temperature and humidity storage test. 23
VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Date : September 13, 2007 ~ September 14, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-1 Testing procedures Test Ab : Cold Test Test Condition : 1. Test Temperature : -40 2. Test Times : 24Hrs 3. Test Environment Curve : Temp 25-40 Time Hrs 0:0 1:30 25:30 27:00 24
VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Equipment : Programmable Temperature & Humidity Chamber K.SON. CO. LTD. Model : THS-DL4+/-150 Date of Calibration : 5/14/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1.The switch button covers, slot can work properly without any interference. 2.All screws are tighten up appropriately. 3.All gaps on the surface are appropriately. 4.Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 25
VITA-350 Low Temp. Storage Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets low temperature storage test. 26
VITA-350 Thermal Profile Test Report No. 07S092A1 Test Date : October 12, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-2 Testing procedures Test Bb : Dry Heat Test Test Condition : 1. Test Temperature : 65 2. Test Times : Each temperature 4 Hrs 3. Test EUT under box with no air flow ambient 4. Test Software : Receive GPRS and GPS signal from satellite and basic station Test Equipment : DATA LOGGER YOKOGAWA CO. LTD. Model : up-1800 S/N : 47XS0063 Date of Calibration : 9/12/2007 27
VITA-350 Thermal Profile Test Report No. 07S092A1 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. Test Data : NUM Parts List Measurement Calculation SEPC. 28.6 65 1. Ublox LEA-4S-0-000 37.2 73.6 85 2. Infineon PMB7850C 38.3 74.7 90 3. M36WDT604 38.6 75.0 105 4. W9825G6CH-75 39.4 75.8 90 5. M LUPXA255A0 41.2 77.6 85 6. Ambient 28.6 65.0 28
VITA-350 Thermal Profile Test Report No. 07S092A1 Test Result : Conclusion : 1. The system specification of thermal profile is 65 degree C. 2. There is no damage in electronic functions or degradation has not been found. 3. Performance is maintained with no incurable physical damage or degradation. Passed The VITA-350 meets thermal profile test. Photo: VITA-350 test photo 29
VITA-350 Random vibration operation test Report No.07S092A1 Test Date : October 17, 2007 Test Site : Integrated Service Technology Inc. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference MIL-STD-810F 514.5C-3 Testing procedures Test Condition : 1. Test Acceleration: X axis 1.62Grms, Y axis 2.05grms, Z axis 2.2Grms 2. Test Frequency : 5-500Hz 3. Test Axis : X, Y, Z axis 4. Test Time : 1hr per axis 5. Test Software : Receive GPRS and GPS signal from satellite and basic station 6. Test Vibration Curve : 30
VITA-350 Random vibration operation test Report No.07S092A1 31
VITA-350 Random vibration operation test Report No.07S092A1 Test Equipment : Vibration Simulator System SHINKEN G-0230N Shake system. S / N: SG-4345 Date of Calibration: 03/29/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button,covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smooth, and no deformed parts found. 32
VITA-350 Random vibration operation test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets random vibration operation test. PHOTO I: VITA-350 Random vibration test Z axis 33
VITA-350 Random vibration operation test Report No.07S092A1 PHOTO II: VITA-350 Random vibration test Y axis 34
VITA-350 Random vibration operation test Report No.07S092A1 PHOTO III: VITA-350 Random vibration test X axis 35
VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Date : September 27, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-6 Testing procedures Test Fc: Vibration sinusoidal Test Test Condition : 1. Test Acceleration: 2G 2. Test Frequency :5-500Hz 3. Test Axis : X,Y,Z axis 4. Test Time : 1Hr per axis 5. Test Vibration Curve : Acceleration 2G Displacement 4.4mm 5Hz 15Hz 500Hz 36
VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-600F2K-40N120 S / N: MC107142493 Date of Calibration: 09/12/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 Rev.A1 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button,covers,slot can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smooth,and no deformed parts found. 37
VITA-350 Sine vibration non-operation test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets sine vibration non-operation test. PHOTO I: VITA-350 Sine vibration test Z axis 38
VITA-350 Sine vibration non-operation test Report No.07S092A1 PHOTO II: VITA-350 Sine vibration test X axis 39
VITA-350 Sine vibration non-operation test Report No.07S092A1 PHOTO III: VITA-350 Sine vibration test Y axis 40
VITA-350 Package Vibration Test Report No.07S092A1 Test Date : September 27, 2007 Test Site : Advantech QA Environment Lab Performed By : Knight Hu Purpose : The DVT test. Test Standard : Reference IEC60068-2-64 Testing procedures Test Fh : Vibration broadband random test Test Condition : 1. Test PSD : 0.026G²/Hz (2.16Grms) 2. Test Frequency : 5-500Hz 3. Test Axis : X,Y and Z axis 4. Test Time : 30 minutes per axis 5. Test Curve : PSD 0.026g²/Hz Acceleration 2.16Grms -6db/oct 5Hz 100Hz 500Hz 41
VITA-350 Package Vibration Test Report No.07S092A1 Test Equipment : Vibration Simulator System KING DESIGN Co. LTD. Model: 9363EM-600F2K-40N120 S / N: MC107142493 Date of Calibration: 09/12/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. 2. The system should not have degradation in its performance. Mechanical function check: 1. The switch button covers can work properly without any interference. 2. All screws are tighten up appropriately. 3. All gaps on the surface are appropriately. 4. Assembling/disassembling the system enclosure or mechanical parts must be smoothes, and no deformed parts found. 42
VITA-350 Package Vibration Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 System meets package vibration test. PHOTO I: VITA-350 package vibration test Z axis 43
VITA-350 Package Vibration Test Report No.07S092A1 PHOTO II: VITA-350 package vibration test X axis 44
VITA-350 Package Vibration Test Report No.07S092A1 PHOTO III: VITA-350 package vibration test Y axis 45
VITA-350 Package drop Test Report No.07S092A1 Test Date : September 19, 2007 Test Site : Advantech QA Environment Lab Performed By: Knight Hu Purpose : The DVT test Test Standard : Reference Federal Standard 101 Method 5007 Testing procedure B Test Ea : Drop Test Test Condition : 1. Test Phase : One corner Three edges Six faces 2. Test High : 100cm 3. Package Weight : 600 g 4. Package Dimension : 25.5cm 18.0cm 6.0cm 5. Test Drawing : Topside Rear Side Left Side Right Side Bottom Side Mid Edge Front Side Short Edge Long Edge Damage Corner 46
VITA-350 Package drop Test Report No.07S092A1 Test Equipment : Drop Tester Machine TOSHIDA SEIKI Co. LTD. Model : DT-100B Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate programs and should pass the inspection. Mechanical function check: 1. The connectors should work properly without any interference. 2. All components and screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the board enclosure must be smooth, and no deformed parts should be found. Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. 47
VITA-350 Package drop Test Report No.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets package drop test. 48
VITA-350 Package drop Test Report No.07S092A1 PHOTO I: VITA-350 structure photo 49
VITA-350 Package drop Test Report No.07S092A1 PHOTO II: VITA-350 corner test photo 50
VITA-350 Package drop Test Report No.07S092A1 PHOTO III: VITA-350 edge test photo 51
VITA-350 Package drop Test Report No.07S092A1 PHOTO IV: VITA-350 face test photo 52
VITA-350 Shock Test ReportNo.07S092A1 Test Date : October 17, 2007 Test Site : Integrated Service Technology Lab. Performed By : Knight Hu Purpose : The DVT test Test Standard : Reference IEC60068-2-27 testing procedures Test Ea : Shock test Test Condition : Shock Acceleration 50G 1. Test condition : Operation, Receive GPRS and GPS signal from satellite and basic station 2. Test pulse shape : half sine wave 3. Test acceleration 50G, pulse duration 11 ms 4. Test method : six faces (front, rear, left, right, top & bottom side) three times per side 5. Test Curve : Half Sine Wave 11ms Pulse Duration time 53
VITA-350 Shock Test ReportNo.07S092A1 Test Equipment : LAB AUTO-SHOCK II 2432 Shock tester Serial Number : 181028 Date of Calibration : 03/29/2007 Sample Configuration & Quantity Under Test : Using one VITA-350 with the following options installed : 1. Main board: VITA-350 REV.A1 2. Wireless LAN: SIEMENS 133851-V02 Performance Criteria : Electronic function check: 1. All system functions must be checked with appropriate testing programs and should pass the inspection. Mechanical function check: 1. The cover and connectors should work properly without any interference. 2. All screws should be tightened up appropriately. 3. All gaps on the surface are appropriately. 4. The assembling/disassembling of the system enclosure or mechanical parts must be smooth,and no deformed parts should be found. 54
VITA-350 Shock Test ReportNo.07S092A1 Test Result : There is no damage in electronic and mechanical functions. Degradation has not been found. Performance is maintained with no incurable physical damage or degradation. Conclusion : Passed. The VITA-350 meets shock test. 55
VITA-350 Shock Test ReportNo.07S092A1 PHOTO I: VITA-350 shock test for bottom side 56
VITA-350 Shock Test ReportNo.07S092A1 PHOTO II: VITA-350 shock test for top side 57
VITA-350 Shock Test ReportNo.07S092A1 PHOTO III: VITA-350 shock test for right side 58
VITA-350 Shock Test ReportNo.07S092A1 PHOTO IV: VITA-350 shock test for left side 59
VITA-350 Shock Test ReportNo.07S092A1 PHOTO V: VITA-350 shock test for rear side 60
VITA-350 Shock Test ReportNo.07S092A1 PHOTO VI: VITA-350 shock test for front side 61