Trabecular Metal Acetabular Revision System Cup-Cage Construct

Similar documents
Trabecular Metal Revision Shell. Surgical Technique IMAGE TO COME. The Best Thing Next to Bone

Biodynamics medical technology is the centre of excellence in the area of endoprosthetics and is specialised in joint implants and instruments.

Ultraporous Acetabular Surfaces are Needed PRO

Trabecular Metal Technology

EasyClip Xpress Sterile staple solution. Operative technique

510(k) Summary NOV

ReCap Technical Design Rationale

CAUTION: U.S. Federal law restricts this device to sale by or on the order of a licensed physician.

MACKERAL OIL TOOLS PVT. LTD.

Final Document IMDRF/PMD WG/N49 FINAL:2018. Title: Definitions for Personalized Medical Devices. Authoring Group: IMDRF Personalized Medical Devices

HydroSet. Injectable HA Bone Substitute

Proven 1-4, Safe Performance. Product overview

RAPIDSORB Injectable Polymer System (IPS) Surgical Technique

Clotalyst. Autologous Activation Solution. Surgical Technique

References. One Surgeon. One Patient. FLM /08

Joint Replacement Implants Hip Joint Prostheses

Orthopaedic Implant Micromotion Sensing Using An Eddy Current Sensor

This publication is not intended for distribution in the USA. PRODUCT RATIONALE

One Surgeon. One Patient. FLH /11

LITe LIF Less invasive posterior lumbar interbody fusion procedure

RAPIDSORB Injectable Polymer System (IPS) Surgical Technique

Choosing the Correct Roller Housed Unit Step by Step

Advancing the Open Ventral Hernia Repair Experience

Meso BioMatrix Acellular Peritoneum Matrix RECOMMENDED TECHNIQUE GUIDE. Recreating harmonious bodies for a new vision of rebirth.

PRECISION-MACHINED COMPONENTS FOR MEDICAL APPLICATIONS. Case Studies

Model #369S-PR. 8/23/2016 Page 1 of 11

MIIG INJECTABLE Graft The following languages are included in this packet:

Micro-Electrode Arrays (MEA), Micro-Wire Arrays (MWA)

Technical Bulletin No. MK3176. PREPARED: July, 2010

Model # 358H-PR. 4/8/2011 Page 1 of 12

Installation Instructions

Standard Specification for Stainless Steels for Surgical Instruments 1

3034 Owen Drive Antioch, TN USA Fax: Maybachstraße 10. Revised 01/17

Model # PR /21/2018 Page 1 of 10

ASAHI Masters PARKWAY HF KIT

SERVICE PARTS LIST G54A BULLETIN NO CHEST CATALOG NO. CABINET CATALOG NO SERIAL

30mm Height Linear Drain Shower Trays

DESIGN OF AN ANTHROPOMORPHIC INTENSITY MODULATED RADIATION THERAPY QUALITY ASSURANCE PHANTOM

RapidPort EZ Access Port Kit DIRECTIONS FOR USE (DFU)

LAP-BAND System Access Port II Kit

Model # 362S-RDP. 9/17/2012 Page 1 of 12

Wright Medical Group, Inc.

Preparation and Installation of the MX-9T Rupture Disc / MX-9T / MX-9T-RH Holder Assembly

AXIOM Indirect Light Coves

Model # 504S-P. 9/14/2011 Page 1 of 9

Degenerative and Deformity Rods. Posterior thoracolumbar rod offering.

PHP8 & PHP30 Series Hydraulic Pushers

Platelet Concentrate in Total Knees BIOLOGICS. This brochure is for International use only. It is not for distribution in the United States.

NORIAN DRILLABLE TECHNICAL MONOGRAPH. Fiber reinforced calcium phosphate phate bone void filler

8000 PIVOT EXPORT 6-5/8" PIPE 90" COUPLER SPACING

INSTRUCTIONS FOR USE FOR:

ExcelGel 2-D Homogeneous Instructions

Conversion Station Model 711

CANNULATED ROUND BARS IN STAINLESS STEELS AND TITANIUM ALLOYS FOR SURGICAL TOOLS AND IMPLANTS. Main Catalog

OSCILLATING SAW BLADES PAT. PENDING SPEZIAL TOOTHING

Com-Tray. Under Floor

CENTRUM CUP STACKER OPERATIONAL INSTRUCTIONS

CS-13 TRENCHLESS TECHNOLOGY TABLE OF CONTENTS

More than surface deep

Model #369SM-RDP. 8/23/2016 Page 1 of 10

Eccentric casing drilling syste

San Antonio Water System Standard Specifications for Construction ITEM NO. 812 WATER MAIN INSTALLATION

Comfort your patient deserves. Strength you demand.

Trenchless building entries Power and communication. Always. Reliable. Tight. cablepipebuildingentry+ Advantages:

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Bone Marrow Concentration. For customized cellular concentrations of platelet-rich plasma from bone marrow aspirate

Model #369S-RDP. 8/23/2016 Page 1 of 11

Johnson. We now offer a real step forward in reliability with our newly designed riser pipes.

Universal Elevator Mount Owners Manual

Medical Device Design & Manufacturing

Model # 338S-RDP. 7/31/2012 Page 1 of 13

MANUFACTURER, IMPORTER AND DISTRIBUTOR FASTENERS, COMPONENTS AND SEALING DEVICES

Model # 358PS-OP. 12/13/2013 Page 1 of 12

Fiberglass Dispenser Sump

[Amdt , 60 FR 50336, Sept. 28, 1995; 60 FR 54409, Oct. 23, 1995, as amended at 69 FR 3696, Jan. 26, 2004; 70 FR 56099, Sept.

Infant Warmer Care Station Cabinet Light

Model # 358PS-RDP. 12/13/2013 Page 1 of 12

company products development production innovation service customized products co-operation

APPENDIX J PROFICIENCY CHECKLISTS

Surgical Technique. and Product Catalog FOR NON-USA USE ONLY

Toilet Seat Installation Guide

SpotClip. Downlight covers for safe lighting installation in suspended ceilings

CoAxial Spray Kit And Applicator Tips. Simplifying the Application of Platelet and Plasma Concentrate

Leadership Through Technology. GPS III Platelet Separation System

Cornerview Shower Enclosure & Base

Model # 158-P4. 12/12/2013 Page 1 of 11

CapSure Permanent Fixation System

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

ASAHI Masters PARKWAY SOFT. ASAHI Masters PARKWAY HF

Product Bulletin BPS-102 Revision 2.6 January F l e x B a l l a n d R o t a B a l l J o i n t s

Model # 238HS-P8. 4/27/2011 Page 1 of 11

CANNULATED ROUND BARS IN STAINLESS STEELS AND TITANIUM ALLOYS FOR SURGICAL TOOLS AND IMPLANTS

ART /2017-E. Mega Fix. Bioabsorbable and composite interference screws

Exactech Investor Update

PeopleNet Display.5 INSTALLATION GUIDE TRANSFORMING THE WAY THE WORLD WORKS

POLYSITE Low Profile Hybrid Ports. Comfort your patient deserves. Strength you demand.

Discerning in-vivo corrosion mechanisms and failure modes of explanted prostheses Part II. By Norman Munroe, Christopher Emerson and Kinzy Jones,

Conformability without Compromise

Model # 358-OP. 8/5/2014 Page 1 of 12

A Sterile Processing User s Guide

Transcription:

Trabecular Metal Acetabular Revision System Cup-Cage Construct Surgical Technique The Best Thing Next to Bone

Trabecular Metal Acetabular Revision System Cup-Cage Construct Trabecular Metal Acetabular Revision System Cup-Cage Construct Surgical Technique developed in conjunction with Neil Bergman, FRACS Heidelberg, Vic Australia Stephen Bubb, MD Kansas City, MO Daniel Estok, MD Boston, MA Allan Gross, MD Toronto, ON Canada Table of Contents Supplementing Stability, Recreating Mobility 2 Cup-Cage Construct Surgical Technique 3 Exposure and Acetabular Assessment 3 Prepare the Acetabulum 3 Implant the Revision Shell 3 Prepare Ischial Notch for Inferior Flange 4 Shaping the Cage 4 Implant the Cage 5 Insert the Acetabular Liner 6 Order Information 7 David Lewallen, MD Rochester, MN Wayne Paprosky, MD Chicago, IL Steven H. Weeden, MD Fort Worth, TX

Trabecular Metal Acetabular Revision System Cup-Cage Construct Supplementing Stability, Recreating Mobility The Trabecular Metal Acetabular Revision System Cage is used in situations where the Trabecular Metal Revision Shell, with or without augmentation, does not provide adequate stability. Initial stability provided by the cage combines with excellent potential for bone ingrowth and long-term stability offered by the Trabecular Metal Revision Shell. The Cup-Cage construct is created by implanting the cage into the Trabecular Metal Revision Shell and cementing the Longevity Highly Crosslinked Polyethylene Liner into the Cup-Cage construct. Cementing the three components creates a single construct and eliminates concerns of micromotion. The cage spans acetabular defects and pelvic discontinuities to provide mechanical stability of the Cup-Cage construct until biological ingrowth occurs within the Trabecular Metal Revision Shell. Modularity of the system offers intraoperative sizing and positioning flexibility to maximize options for various patient anatomies. Dome holes in the cage allow optimal screw fixation through the Revision Shell into viable host bone. The superior flange is available in two different lengths (long-10 holes, and short-5 holes) to meet a wide range of anatomical needs. The inferior flange is designed to be spiked into the ischium. Flanges can be shaped to fit individual patient anatomy. Commercially Pure Titanium material provides excellent strength and biocompatibility.

Trabecular Metal Acetabular Revision System Cup-Cage Construct Cup-Cage Construct Surgical Technique The decision to use the Trabecular Metal Acetabular Revision System Cage to create a Cup-Cage construct is made after the Trabecular Metal Revision Shell, with or without augmentation, has been implanted and it is determined that there is not adequate stability for the acetabular reconstruction. A cage is then cemented into the revision shell to supplement the immediate stability until biological fixation of the Trabecular Metal Revision Shell can occur. Exposure and Acetabular Assessment Expose the acetabulum. Carefully assess any acetabular bone defects, noting the location, extent, and defect type (Fig. 1). Also assess the quality and location of the host bone that remains for support of the acetabular reconstruction. Determine which Trabecular Metal components will be used to reconstruct the acetabulum. If a Trabecular Metal Restrictor is to be used, it should be placed before the other components. Pelvic Discontinuity Prepare the Acetabulum Use morselized bone and structural graft as needed to reconstruct the acetabulum. Use ball impactors and/or reverse reaming to impact the bone graft. Identify the hip center and use the acetabular reamers to size and shape the acetabulum for the Trabecular Metal Revision Shell (Fig. 2). The diameter of the last reamer used to shape the acetabulum will match the labeled diameter of the Trabecular Metal Revision Shell. The amount of press fit used should be determined at the time of surgery and be based upon bone quality. Implant the Revision Shell Impact the shell into the prepared acetabulum, ensuring that the cluster of holes is positioned posterosuperiorly or where the best host bone contact can be achieved. Use a depth gauge through the screw holes to assess the contact between the acetabular cup and the host bone (Fig. 3). Then drill the screw holes and insert 6.5mm HGP II cancellous screws. Bicortical screw fixation is not necessary. Note: Do not overtighten the screws. Optional: Bone wax covering unused screw holes can prevent cement extrusion through the holes and potential interference with bone ingrowth into the Trabecular Metal Revision Shell. Additionally, covering screw heads may aid in screw removal if future revision surgery is needed. Fig. 2 Fig. 3 Bone Loss Fig. 1 Bone Loss With the Trabecular Metal Revision Shell and/or other Trabecular Metal components in place, assess the stability of the construct within the acetabulum. When additional stability is needed, the Trabecular Metal Acetabular System Cage can be used to provide initial stability until biological ingrowth within the Trabecular Metal material provides long-term stability (Fig. 4). Fig. 4

Trabecular Metal Acetabular Revision System Cup-Cage Construct Prepare Ischial Notch for Inferior Flange Palpate the posterior rim of the acetabulum from superior to inferior to identify the ischium. Drill a small hole and use a depth gauge to confirm that the ischium has been located (Fig. 5). The depth gauge should indicate at least 2.5cm of bone. Drill additional holes to confirm the proper orientation, ensuring that the location is surrounded by adequate bone stock. Hold a small osteotome (or bent chisel) in line with the ischium and initiate a slot in the bone to accept the inferior flange of the cage (Fig. 6). Note: By inserting the inferior flange into the ischium via the prepared notch, the sciatic nerve is protected. The inferior flange should not be fixed on the surface of the ischium. Insert the inferior flange of the cage into the slot and use the flange to complete preparation of the ischial notch. Note: If it is pre-determined that a Cup-Cage construct is needed to provide stability prior to the implantation of the Revision Shell, preparation of the ischial notch can be performed before the Revision Shell is inserted. Shaping the Cage Contour the cage to obtain proper flange shape and fit using plate benders (Fig. 7). The superior flanges are usually bent towards the ilium and the inferior flange is bent to accommodate the curve of the ischium. Fig. 6 Fig. 5 Fig. 7

Trabecular Metal Acetabular Revision System Cup-Cage Construct WARNING: Avoid reverse or repeated bending of the titanium implant as this may weaken or break the flange. When bending the cage, care should be taken to avoid marring or damaging the implant. It is important to completely contour the implant before inserting screws so the cage will not be displaced when the screws are tightened (Fig. 8). Fig. 8 Implant the Cage Once the desired shape of the cage has been achieved, insert the inferior flange into the ischial notch (Fig. 9). Use a spiked ball-pusher if necessary to fully seat the cage (Fig. 10). Next, position the superior flange against the lateral portion of the ilium. Then impact the dome of the cage. It is not necessary for the cage to bottom out in the shell. Fig. 9 Fig. 10

Trabecular Metal Acetabular Revision System Cup-Cage Construct For additional stabilization, HGP II screws may be inserted through the existing holes in the dome and into the Trabecular Metal Shell (Fig. 11). Once the cage is in the proper position, insert screws (Trilogy or HGP II bone screws) through the holes in the superior flange of the cage (Fig. 12). Insert the Acetabular Liner Apply doughy Palacos * bone cement into the dome of the cage (Fig. 13). Finger pack to assure that cement passes through the holes in the cage to fill gaps between the cage and the acetabular shell. Then insert the Longevity Highly Crosslinked Polyethylene Revision Shell Liner into the desired position with the liner rim fully seated on the face of the cage (Fig. 14). Revision Shell Liners are available in several head articulation options, including 28, 32, 36, and 40mm inner diameters. Fig. 11 Fig. 12 Remove excess cement with a curette. Fig. 14 Fig. 13 * PALACOS is a trademark of Heraeus Kulzer GmbH. Under license from Heraeus Kulzer GmbH, Hanau, Germany.

Trabecular Metal Acetabular Revision System Cup-Cage Construct Order Information Trabecular Metal Acetabular Revision System Cages 00-7123-056-48 Short Flange Cage 56/58/60 shell, 48 liner, right 00-7123-062-54 Short Flange Cage 62/64 shell, 54 liner, right 00-7123-066-58 Short Flange Cage 66/68/70 shell, 58 liner, right 00-7123-072-64 Short Flange Cage 72/74 shell, 64 liner, right 00-7123-076-68 Short Flange Cage 76/78/80 shell, 68 liner, right 00-7124-056-48 Short Flange Cage 56/58/60 shell, 48 liner, left 00-7124-062-54 Short Flange Cage 62/64 shell, 54 liner, left 00-7124-066-58 Short Flange Cage 66/68/70 shell, 58 liner, left 00-7124-072-64 Short Flange Cage 72/74 shell, 64 liner, left 00-7124-076-68 Short Flange Cage 76/78/80 shell, 68 liner, left 00-7125-056-48 Long Flange Cage 56/58/60 shell, 48 liner, right 00-7125-062-54 Long Flange Cage 62/64 shell, 54 liner, right 00-7125-066-58 Long Flange Cage 66/68/70 shell, 58 liner, right 00-7125-072-64 Long Flange Cage 72/74 shell, 64 liner, right 00-7125-076-68 Long Flange Cage 76/78/80 shell, 68 liner, right 00-7126-056-48 Long Flange Cage 56/58/60 shell, 48 liner, left 00-7126-062-54 Long Flange Cage 62/64 shell, 54 liner, left 00-7126-066-58 Long Flange Cage 66/68/70 shell, 58 liner, left 00-7126-072-64 Long Flange Cage 72/74 shell, 64 liner, left 00-7126-076-68 Long Flange Cage 76/78/80, shell, 68 liner, left Longevity Revision Shell Liner 0 Neutral (cont.) Prod. No. Description 00-7105-062-28 28mm ID, 62/64mm OD 00-7105-066-28 28mm ID, 66/68/70mm OD 00-7105-072-28 28mm ID, 72/74mm OD 00-7105-076-28 28mm ID, 76/78/80mm OD 00-7105-054-32 32mm ID, 54mm OD 00-7105-056-32 32mm ID, 56mm OD 00-7105-058-32 32mm ID, 58mm OD 00-7105-060-32 32mm ID, 60mm OD 00-7105-062-32 32mm ID, 62/64mm OD 00-7105-066-32 32mm ID, 66/68/70mm OD 00-7105-072-32 32mm ID, 72/74mm OD 00-7105-076-32 32mm ID, 76/78/80mm OD 00-7105-058-36 36mm ID, 58mm OD 00-7105-060-36 36mm ID, 60mm OD 00-7105-062-36 36mm ID, 62/64mm OD 00-7105-066-36 36mm ID, 66/68/70mm OD 00-7105-072-36 36mm ID, 72/74mm OD 00-7105-076-36 36mm ID, 76/78/80mm OD 00-7105-062-40 40mm ID, 62/64mm OD 00-7105-066-40 40mm ID, 66/68/70mm OD 00-7105-072-40 40mm ID, 72/74mm OD 00-7105-076-40 40mm ID, 76/78/80mm OD Reconstruction Instruments 00-8005-000-02 Reconstruction Instrument Set (Includes all items listed below) 00-6260-018-00 Cup Positioner 00-4816-060-00 Ball Spike 00-1179-011-11 Lever Bender (2 in set) 00-1179-011-00 Plate Bender 00-2371-001-00 Bending Iron (2 in set) 00-6260-003-01 Drill Bit 3.2 x 15mm 00-6260-003-02 Drill Bit 3.2 x 30mm 00-6260-003-03 Drill Bit 3.2 x 45mm 00-6260-002-00 Modular Flexible Shaft 00-6260-025-00 Universal Screwdriver Shank, 3.5mm 00-6260-024-00 Straight Screwdriver Shank, 3.5mm 00-6260-026-00 Modular Ratchet Screwdriver Handle 00-6260-006-00 Drill Guide 00-6611-098-00 Drill Depth Gauge 00-6260-007-01 Tap, 4.5mm 00-6260-007-02 Tap, 6.5mm 00-6260-010-00 Modular Tap Handle 00-6260-008-01 Tap Guide, 4.5mm 00-6260-008-02 Tap Guide, 6.5mm 00-8005-090-00 Reconstruction Instrument Case 0086 Trabecular Metal Revision Shell Prod. No. Description 00-7000-048-20 48mm Cup Size 00-7000-050-20 50mm Cup Size 00-7000-052-20 52mm Cup Size 00-7000-054-20 54mm Cup Size 00-7000-056-20 56mm Cup Size 00-7000-058-20 58mm Cup Size 00-7000-060-20 60mm Cup Size 00-7000-062-20 62mm Cup Size 00-7000-064-20 64mm Cup Size 00-7000-066-20 66mm Cup Size 00-7000-068-20 68mm Cup Size 00-7000-070-20 70mm Cup Size 00-7000-072-70 72mm Cup Size 00-7000-074-70 74mm Cup Size 00-7000-076-70 76mm Cup Size 00-7000-078-70 78mm Cup Size 00-7000-080-70 80mm Cup Size Longevity Revision Shell Liner 0 Neutral Prod. No. Description 00-7105-048-28 28mm ID, 48mm OD 00-7105-050-28 28mm ID, 50mm OD 00-7105-052-28 28mm ID, 52mm OD 00-7105-054-28 28mm ID, 54mm OD 00-7105-056-28 28mm ID, 56mm OD 00-7105-058-28 28mm ID, 58mm OD 00-7105-060-28 28mm ID, 60mm OD Longevity Revision Shell Liner 10 Oblique Prod. No. Description 00-7110-048-28 28mm ID, 48mm OD 00-7110-050-28 28mm ID, 50mm OD 00-7110-052-28 28mm ID, 52mm OD 00-7110-054-28 28mm ID, 54mm OD 00-7110-056-28 28mm ID, 56mm OD 00-7110-058-28 28mm ID, 58mm OD 00-7110-060-28 28mm ID, 60mm OD 00-7110-062-28 28mm ID, 62/64mm OD 00-7110-066-28 28mm ID, 66/68/70mm OD 00-7110-072-28 28mm ID, 72/74mm OD 00-7110-076-28 28mm ID, 76/78/80mm OD 00-7110-054-32 32mm ID, 54mm OD 00-7110-056-32 32mm ID, 56mm OD 00-7110-058-32 32mm ID, 58mm OD 00-7110-060-32 32mm ID, 60mm OD 00-7110-062-32 32mm ID, 62/64mm OD 00-7110-066-32 32mm ID, 66/68/70mm OD 00-7110-072-32 32mm ID, 72/74mm OD 00-7110-076-32 32mm ID, 76/78/80mm OD 00-7110-058-36 36mm ID, 58mm OD 00-7110-060-36 36mm ID, 60mm OD 00-7110-062-36 36mm ID, 62/64mm OD 00-7110-066-36 36mm ID, 66/68/70mm OD 00-7110-072-36 36mm ID, 72/74mm OD 00-7110-076-36 36mm ID, 76/78/80mm OD 00-7110-062-40 40mm ID, 62/64mm OD 00-7110-066-40 40mm ID, 66/68/70mm OD 00-7110-072-40 40mm ID, 72/74mm OD 00-7110-076-40 40mm ID, 76/78/80mm OD 0086

Trabecular Metal Acetabular Revision System Cup-Cage Construct General Instrument Set 00-7000-015-00 General Acetabular Instrument Set for both Trabecular Metal Revision Shell and Monoblock Cup (Includes one each of all items listed below) 00-7050-076-00 Instrument Case Base w/lid (Outer Case) 00-7050-077-00 Instrument Case Bottom Tray 00-7050-078-00 Instrument Case Top Tray 0086 Cup Adapter w/bayonet 00-7045-040-00 40mm Cup Size through through 00-7045-070-00 70 mm Cup Size Available in 2mm increments. General Instruments 00-7050-030-00 Cup Rim Impactor 00-7050-031-00 Cup Version Guide 00-7050-032-00 Provisional Liner Extractor (Monoblock Cup only) 00-7050-033-00 Bayonet Handle w/hudson Adapter (Plunger included) 00-7050-033-01 Plunger (replacement ordered separately) 00-7050-034-00 Provisional Shell Impactor Handle 00-7050-035-00 Medial Cup Impactor (Monoblock Cup only) 00-7050-036-00 Acetabular Impactor Head, 28mm 00-7050-038-00 Acetabular Impactor Head, 22mm Provisional Shell 00-7040-040-00 40mm Cup Size through through 00-7040-070-00 70 mm Cup Size Available in 2mm increments. Provisional Liner 0 Neutral for Monoblock Cup Only* 00-7360-040-22 22mm ID, 40mm Cup Size through through 00-7360-046-22 22mm ID, 46mm Cup Size 00-7360-048-28 28mm ID, 48mm Cup Size through through 00-7360-070-28 28mm ID, 70mm Cup Size Available in 2mm increments. Provisional Liner 10 Elevated for Monoblock Cup Only* 00-7361-040-22 22mm ID, 40mm Cup Size through through 00-7361-046-22 22mm ID, 46mm Cup Size 00-7361-048-28 28mm ID, 48mm Cup Size through through 00-7361-070-28 28mm ID, 70mm Cup Size Available in 2mm increments. 00-7050-095-00 General Instrument Case Holds 0 or 10 Monoblock Provisional Liners * Included in set, but not for use with this Surgical Technique. Revision Shell Provisional Liner Kits 00-7105-000-00 Trabecular Metal Acetabular Revision System Provisional Liner Kit (Includes one each of all items listed below) 00-7106-010-00 Trabecular Metal Acetabular Revision System Provisional Liner Case Provisional Liner 0 Neutral 00-7106-048-28 Revision Provisional Liner zero degree 28mm ID, 48mm OD 00-7106-050-28 Revision Provisional Liner zero degree 28mm ID, 50mm OD 00-7106-052-28 Revision Provisional Liner zero degree 28mm ID, 52mm OD 00-7106-054-28 Revision Provisional Liner zero degree 28mm ID, 54mm OD 00-7106-056-28 Revision Provisional Liner zero degree 28mm ID, 56mm OD 00-7106-058-28 Revision Provisional Liner zero degree 28mm ID, 58mm OD 00-7106-060-28 Revision Provisional Liner zero degree 28mm ID, 60mm OD 00-7106-062-28 Revision Provisional Liner zero degree 28mm ID, 62/64mm OD 00-7106-066-28 Revision Provisional Liner zero degree 28mm ID, 66/68/70mm OD 00-7106-054-32 Revision Provisional Liner zero degree 32mm ID, 54mm OD 00-7106-056-32 Revision Provisional Liner zero degree 32mm ID, 56mm OD 00-7106-058-32 Revision Provisional Liner zero degree 32mm ID, 58mm OD 00-7106-060-32 Revision Provisional Liner zero degree 32mm ID, 60mm OD 00-7106-062-32 Revision Provisional Liner zero degree 32mm ID, 62/64mm OD 00-7106-066-32 Revision Provisional Liner zero degree 32mm ID, 66/68/70mm OD 00-7106-058-36 Revision Provisional Liner zero degree 36mm ID, 58mm OD 00-7106-060-36 Revision Provisional Liner zero degree 36mm ID, 60mm OD 00-7106-062-36 Revision Provisional Liner zero degree 36mm ID, 62/64mm OD 00-7106-066-36 Revision Provisional Liner zero degree 36mm ID, 66/68/70mm OD 00-7106-062-40 Revision Provisional Liner zero degree 40mm ID, 62/64mm OD 00-7106-066-40 Revision Provisional Liner zero degree 40mm ID, 66/68/70mm OD Provisional Liner 10 Oblique 00-7111-048-28 Revision Provisional Liner ten degree 28mm ID, 48mm OD 00-7111-050-28 Revision Provisional Liner ten degree 28mm ID, 50mm OD 00-7111-052-28 Revision Provisional Liner ten degree 28mm ID, 52mm OD 00-7111-054-28 Revision Provisional Liner ten degree 28mm ID, 54mm OD 00-7111-056-28 Revision Provisional Liner ten degree 28mm ID, 56mm OD 00-7111-058-28 Revision Provisional Liner ten degree 28mm ID, 58mm OD 00-7111-060-28 Revision Provisional Liner ten degree 28mm ID, 60mm OD 00-7111-062-28 Revision Provisional Liner ten degree 28mm ID, 62/64mm OD 00-7111-066-28 Revision Provisional Liner ten degree 28mm ID, 66/68/70mm OD Provisional Liner 10 Oblique (cont.) 00-7111-054-32 Revision Provisional Liner ten degree 32mm ID, 54mm OD 00-7111-056-32 Revision Provisional Liner ten degree 32mm ID, 56mm OD 00-7111-058-32 Revision Provisional Liner ten degree 32mm ID, 58mm OD 00-7111-060-32 Revision Provisional Liner ten degree 32mm ID, 60mm OD 00-7111-062-32 Revision Provisional Liner ten degree 32mm ID, 62/64mm OD 00-7111-066-32 Revision Provisional Liner ten degree 32mm ID, 66/68/70mm OD 00-7111-058-36 Revision Provisional Liner ten degree 36mm ID, 58mm OD 00-7111-060-36 Revision Provisional Liner ten degree 36mm ID, 60mm OD 00-7111-062-36 Revision Provisional Liner ten degree 36mm ID, 62/64mm OD 00-7111-066-36 Revision Provisional Liner ten degree 36mm ID, 66/68/70mm OD 00-7111-062-40 Revision Provisional Liner ten degree 40mm ID, 62/64mm OD 00-7111-066-40 Revision Provisional Liner ten degree 40mm ID, 66/68/70mm OD Revision Shell Jumbo Provisional Liner Kit 00-7105-001-00 Trabecular Metal Acetabular Revision System Jumbo Provisional Liner Kit (Includes one each of all items listed below) 00-7106-015-00 Trabecular Metal Acetabular Revision System Jumbo Provisional Liner Case Jumbo Provisional Liner 0 Neutral 00-7106-072-28 Revision Provisional Liner zero degree 28mm ID, 72/74mm OD 00-7106-076-28 Revision Provisional Liner zero degree 28mm ID, 76/78/80mm OD 00-7106-072-32 Revision Provisional Liner zero degree 32mm ID, 72/74mm OD 00-7106-076-32 Revision Provisional Liner zero degree 32mm ID, 76/78/80mm OD 00-7106-072-36 Revision Provisional Liner zero degree 36mm ID, 72/74mm OD 00-7106-076-36 Revision Provisional Liner zero degree 36mm ID, 76/78/80mm OD 00-7106-072-40 Revision Provisional Liner zero degree 40mm ID, 72/74mm OD 00-7106-076-40 Revision Provisional Liner zero degree 40mm ID, 76/78/80mm OD Jumbo Provisional Liner 10 Oblique 00-7111-072-28 Revision Provisional Liner ten degree 28mm ID, 72/74mm OD 00-7111-076-28 Revision Provisional Liner ten degree 28mm ID, 76/78/80mm OD 00-7111-072-32 Revision Provisional Liner ten degree 32mm ID, 72/74mm OD 00-7111-076-32 Revision Provisional Liner ten degree 32mm ID, 76/78/80mm OD 00-7111-072-36 Revision Provisional Liner ten degree 36mm ID, 72/74mm OD 00-7111-076-36 Revision Provisional Liner ten degree 36mm ID, 76/78/80mm OD 00-7111-072-40 Revision Provisional Liner ten degree 40mm ID, 72/74mm OD 00-7111-076-40 Revision Provisional Liner ten degree 40mm ID, 76/78/80mm OD 0086 0086

Revision Shell Rim Impactor Kit 00-7105-003-00 Trabecular Metal Acetabular Revision System Impactor Kit (Includes one each of all items listed below) 00-7106-005-00 Trabecular Metal Acetabular Revision System Impactor Case 00-7330-048-00 48mm Rim Impactor 00-7330-050-00 50mm Rim Impactor 00-7330-052-00 52mm Rim Impactor 00-7330-054-00 54mm Rim Impactor 00-7330-056-00 56mm Rim Impactor 00-7330-058-00 58mm Rim Impactor 00-7330-060-00 60mm Rim Impactor 00-7330-062-00 62/64mm Rim Impactor 00-7330-066-00 66/68/70mm Rim Impactor 00-7330-072-00 72/74mm Rim Impactor 00-7330-076-00 76/78/80mm Rim Impactor 00-7050-030-00 Cup Rim Impactor 00-7050-031-00 Cup Version Guide 00-7050-033-00 Bayonet Handle 00-7050-034-00 Provisional Shell Impactor Handle 00-7050-001-28 Acetabular Impaction Head, 28mm 00-7050-001-32 Acetabular Impaction Head, 32mm 00-7050-001-36 Acetabular Impaction Head, 36mm 00-7050-001-40 Acetabular Impaction Head, 40mm Modular Cup Provisional Shell Set 00-6270-099-02 Mod Cup Provisional Shell Set (Includes one each of all items listed below) 00-6270-015-00 Provisional Shell Case 00-6242-040-00 Shell Provisional 40mm 00-6242-042-00 Shell Provisional 42mm 00-6242-044-00 Shell Provisional 44mm 00-6242-046-00 Shell Provisional 46mm 00-6242-048-00 Shell Provisional 48mm 00-6242-050-00 Shell Provisional 50mm 00-6242-052-00 Shell Provisional 52mm 00-6242-054-00 Shell Provisional 54mm 00-6242-056-00 Shell Provisional 56mm 00-6242-058-00 Shell Provisional 58mm 00-6242-060-00 Shell Provisional 60mm 00-6242-062-00 Shell Provisional 62mm 00-6242-064-00 Shell Provisional 64mm 00-6242-066-00 Shell Provisional 66mm 00-6242-068-00 Shell Provisional 68mm 00-6242-070-00 Shell Provisional 70mm Jumbo Shell Provisional Set 00-6270-199-02 Jumbo Shell Provisional Set (Includes one each of all items listed below) 00-6275-018-00 Mod Cup Provisional Shell Jumbo Tray 00-6242-072-00 Shell Provisional 72mm 00-6242-074-00 Shell Provisional 74mm 00-6242-076-00 Shell Provisional 76mm 00-6242-078-00 Shell Provisional 78mm 00-6242-080-00 Shell Provisional 80mm HGP II Bone Screws Prod. No. Description 00-6624-065-15 6.5mm x 15mm 00-6624-065-20 6.5mm x 20mm 00-6624-065-25 6.5mm x 25mm 00-6624-065-30 6.5mm x 30mm 00-6624-065-35 6.5mm x 35mm 00-6624-065-40 6.5mm x 40mm 00-6624-065-50 6.5mm x 50mm 00-6624-065-60 6.5mm x 60mm Trilogy Bone Screws Prod. No. Description 00-6250-065-15 6.5mm x 15mm 00-6250-065-20 6.5mm x 20mm 00-6250-065-25 6.5mm x 25mm 00-6250-065-30 6.5mm x 30mm 00-6250-065-40 6.5mm x 40mm 00-6250-065-50 6.5mm x 50mm 00-6250-065-60 6.5mm x 60mm 0086 Screw Instruments 00-6260-099-02 Trilogy Holed Instrument Set (Includes one of each of all items listed below) 00-6260-002-00 Flex Shaft w/modular Connector 00-6260-003-01 Drill Bit, 15mm Length 00-6260-003-02 Drill Bit, 30mm Length 00-6260-003-03 Drill Bit, 45mm Length 00-6260-006-00 Drill Guide 00-6260-007-01 Tap, 4.5mm Diameter 00-6260-008-01 Tap Guide, 4.5mm Diameter 00-6260-008-02 Tap Guide, 6.5mm Diameter 00-6260-010-00 Tap Handle 00-6260-024-00 Straight Screwdriver 00-6260-025-00 Universal Screwdriver 00-6260-026-00 Modular Universal Handle 00-6260-013-00 Screw Holding Forceps, 15 00-6260-014-00 Screw Holding Forceps, 45 00-6611-098-00 Depth Gauge 00-6260-085-01 Case (including base and lid) 00-4215-200-00 Screwdriver Torque Limiter (ordered separately, not in kit)

Please refer to package insert for complete product information, including contraindications, warnings, precautions and adverse effects. Contact your Zimmer representative or visit us at www.zimmer.com +H124977255146001/$070207B07A 97-7255-146-00 3.5ML Printed in the USA 2007 Zimmer, Inc.