DIVISION: UTILITIES SECTION: SUBDRAINAGE REPORT HOLDER: ROYAL BUILDING PRODUCTS (USA) INC.

Similar documents
DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC RAILINGS SECTION: STRUCTURAL PLASTICS REPORT HOLDER:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: CPG INTERNATIONAL LLC DBA THE AZEK COMPANY LLC EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: METALS SECTION: METAL RAILINGS REPORT HOLDER: ULTRALOX 2955 LONE OAK DRIVE, SUITE 180 EAGAN, MINNESOTA 55121

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER: FYPON, LTD.

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: FLOOD FLAPS, LLC EVALUATION SUBJECT:

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS LLC

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A MITEK COMPANY

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: KINGSPAN LIGHT + AIR LLC

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS DIVISION: SIDING REPORT HOLDER: VM ZINC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

DIVISION: OPENINGS SECTION: VENTS/FOUNDATION FLOOD VENTS REPORT HOLDER: SMARTVENT PRODUCTS, INC.

DIVISION: OPENINGS SECTION: UNIT SKYLIGHTS REPORT HOLDER: SKYCO SKYLIGHTS 2995 AIRWAY AVENUE, SUITE B COSTA MESA, CALIFORNIA 92626

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: TEJAS BORJA USA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: ENERCEPT, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION SECTION: WATER-RESISTIVE BARRIERS/WEATHER BARRIERS

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: CERAMICA LA ESCANDELLA, S.A.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KAYCAN LTD.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: RIEDER FASERBETON ELEMENTE GmbH

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS REPORT HOLDER: HB&G BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: KP BUILDING PRODUCTS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: GENTEK BUILDING PRODUCTS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: RIDGE VENTS REPORT HOLDER: VERSCENE, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: CERTAINTEED CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: PLASTIC SIDING REPORT HOLDER: ASSOCIATED MATERIALS, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD I JOISTS REPORT HOLDER: STARK TRUSS COMPANY, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER: BARTILE ROOFS, INC. EVALUATION SUBJECT:

DIVISION: FINISHES SECTION: GYPSUM BOARD REPORT HOLDER: PANEL REY, S.A.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING REPORT HOLDER: SILCA SYSTEM

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PLASTICS SECTION: PLASTIC DECKING REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: SRL INDUSTRIES LTD.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CLAY ROOF TILES REPORT HOLDER: BORAL ROOFING LLC

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

DIVISION: SPECIALTIES SECTION: PROTECTIVE COVERS REPORT HOLDER:

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: TRESPA NORTH AMERICA, LTD.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER:

REPORT HOLDER: R.L. ADAMS PLASTICS, INC CROSSROADS COMMERCE PARKWAY WYOMING, MICHIGAN EVALUATION SUBJECT: POLYCORE BRAND INSULATION

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: FIBER CEMENT SIDING REPORT HOLDER: KMEW CO., LTD. EVALUATION SUBJECT:

REPORT HOLDER: SOPREMA, INC. 310 QUADRAL DRIVE WADSWORTH, OHIO EVALUATION SUBJECT:

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

DIVISION: MASONRY SECTION: MANUFACTURED BRICK MASONRY SECTION: MANUFACTURED STONE MASONRY REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: BARRETTE STRUCTURAL DISTRIBUTION, INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: EVALUATION SUBJECT: STRUCTURAL PANELS

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: EVALUATION SUBJECT:

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

REPORT HOLDER: RARE MANUFACTURING INC A AVENUE SURREY, BRITISH COLUMBIA V4N 4P2 CANADA EVALUATION SUBJECT: IRONWOOD SHAKE

Joint Evaluation Report ICC-ES (800) (562)

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: ELASTOCHEM SPECIALTY CHEMICALS, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

REPORT HOLDER: CLARKDIETRICH BUILDING SYSTEMS 9050 CENTRE POINTE DRIVE, SUITE 400 WEST CHESTER, OHIO EVALUATION SUBJECT:

REPORT HOLDER: BASF CORPORATION EVALUATION SUBJECT: MASTERSEAL AWB 660 I VAPOR RETARDER, AIR AND WATER-RESISTIVE BARRIER AND FLEXIBLE FLASHING

REPORT HOLDER: CALIFORNIA EXPANDED METAL PRODUCTS COMPANY (CEMCO) CROSSROADS PARKWAY NORTH, SUITE 325 CITY OF INDUSTRY, CALIFORNIA 91746

Trusted WOOD I JOISTS SECTION: 06 ON WEB i. Conformity! ICC-ES Evaluation. Copyright 2015

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: STRUCTURAL PANELS REPORT HOLDER: FOUR SEASONS SOLAR PRODUCTS

REPORT HOLDER: MASTER MARK PLASTICS PRODUCTS 210 AMPE DRIVE PAYNESVILLE, MINNESOTA EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: WATER RESISTIVE BARRIERS/WEATHER BARRIERS SECTION: AIR BARRIERS

DIVISION: METALS SECTION: COLD FORMED METAL FRAMING REPORT HOLDER: AEGIS METAL FRAMING, A DIVISION OF MITEK

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SPLICE SLEEVE JAPAN, LTD.

DIVISION: FINISHES SECTION: FIRE RETARDANT COATINGS REPORT HOLDER: FIRE RETARDANT COATINGS OF TEXAS, LLC

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: FUNDERMAX GMBH

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: PLASTIC DECKING SECTION: PLASTIC RAILINGS REPORT HOLDER:

Trusted ICC ES POST MODELS. Look. Conformity! Evaluation. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: SHOP FABRICATED WOOD TRUSSES REPORT HOLDER: MITEK USA, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS REPORT HOLDER: METAL SALES MANUFACTURING CORPORATION

DIVISION: METALS SECTION: METAL FASTENINGS REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS 75024

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: DEMILEC (USA) INC.

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION REPORT HOLDER: SPRAY FOAM POLYMERS

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: THERMAL INSULATION DIVISION: AIR BARRIERS REPORT HOLDER:

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: TENDON SYSTEMS, LLC

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: COMPOSITE WALL PANELS REPORT HOLDER: 3A COMPOSITES USA INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: CONCRETE ROOF TILES REPORT HOLDER:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: NAILS REPORT HOLDER: BOSTITCH FASTENING SYSTEMS

Trusted ICC ES HILTI, INC. Evaluation. report, or as to any. ICC-ES Evaluation

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: SIDING REPORT HOLDER: SHAKERTOWN 1992, INC.

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: GRABBER NAILS FOR GYPSUM WALLBOARD INSTALLATION

DIVISION: FINISHES SECTION: GYPSUM BOARD ACCESSORIES REPORT HOLDER: CONLAB, INC. dba PREST ON CO.

Transcription:

0 Most Widely Accepted and Trusted ICC ES Evaluation Report ICC ES 000 (800) 423 6587 (562) 699 0543 www.icc es.org ESR 3964 Reissued 01/2018 This report is subject to renewal 01/2020. DIVISION: 33 00 00 UTILITIES SECTION: 33 46 00 SUBDRAINAGE REPORT HOLDER: ROYAL BUILDING PRODUCTS (USA) INC. 2810 POST OAK BOULEVARD, SUITE 600 HOUSTON, TEXAS 77056 EVALUATION SUBJECT: FORM A DRAIN FOUNDATION FOOTING FORM AND DRAINAGE SYSTEM Look for the trusted marks of Conformity! 2014 Recipient of Prestigious Western States Seismic Policy Council (WSSPC) Award in Excellence A Subsidiary of ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved.

ICC-ES Evaluation Report ESR-3964 Reissued January 2018 This report is subject to renewal January 2020. www.icc-es.org (800) 423-6587 (562) 699-0543 A Subsidiary of the International Code Council DIVISION: 33 00 00 UTILITIES Section: 33 46 00 Subdrainage REPORT HOLDER: ROYAL BUILDING PRODUCTS (USA) INC. 2810 POST OAK BOULEVARD, SUITE 600 HOUSTON, TEXAS 77056 (713) 960-9111 www.royalbuildingproducts.com info@royalbuildingproducts.com EVALUATION SUBJECT: FORM-A-DRAIN FOUNDATION FOOTING FORM AND DRAINAGE SYSTEM 1.0 EVALUATION SCOPE 1.1 Compliance with the following codes: 2015 International Building Code (IBC) 2015 International Residential Code (IRC) Property evaluated: Foundation Drainage 1.2 Evaluation to the following green standards: 2015, 2012 and 2008 ICC 700 National Green Building Standard (ICC 700-2015, ICC 700-2012 and ICC 700-2008) Attribute verified: See Section 3.1 2.0 USES The Form-A-Drain system is used to provide foundation drainage in accordance with IBC Section 1805.4 and IRC Section R405. 3.0 DESCRIPTION 3.1 General: The Form-A-Drain system consists of 12-foot-long (3.66 m) extruded drainage channels, called lineals, and connectors which are used to connect the lineals to each other and to the drainage pipe which discharges to an approved area in accordance with the IBC or IRC as applicable. Form-A-Drain lineals are manufactured from extruded polyvinyl chloride (PVC) compound. The components of the system are described in Sections 3.2 and 3.3. Figure 1 of this report depicts a typical schematic of the Form-A-Drain system. Figure 2 of this report depicts a section through a typical application of the 6- and 8-inch (150 and 200 mm) lineals. The attributes of the Form-A-Drain system have been verified as conforming to the provisions of ICC 700-2015 and ICC 700-2012 Section 602.1.3.1 and ICC 700-2008 Section 602.3 for foundation drains. Note that decisions on compliance for those areas rest with the user of this report. The user is advised of the project-specific provisions that may be contingent upon meeting specific conditions, and the verification of those conditions is outside the scope of this report. These codes or standards often provide supplemental information as guidance. 3.2 Form-A-Drain Lineals The Form-A-Drain lineals are 12 feet long (3.66 m), available in heights of 4, 6, 8, and 10 inches (100, 150, 205, and 254 mm). The 4-inch (100 mm) lineals have a single chamber. The 6-, 8-, and 10-inch (150, 205, and 254 mm) lineals are manufactured as hollow tubes with solid intermediate webs, which stiffen the tubes and create upper and lower chambers of equal size. See Figure 3 of this report for an illustration of a lineal. Water enters these chambers through slots in the exterior vertical face of the lineal, and passes through the system to outlet fittings which provide the connection of the Form-A-Drain to an approved discharge area in accordance with the IBC or IRC as applicable. 3.3 Form-A-Drain Fittings The Form-A-Drain Fittings are used to connect the lineals to each other and to connect the foundation drain system created by Form-A-Drain to an approved drainage disposal system. The fittings consist of straight couplings, 45 and 90 corners, vertical 90 L and Tee couplings and straight couplings with single and double outlet fittings. See Figure 3 of this report for illustrations of the various fitting types. The straight couplings and the 45 and 90 corners are manufactured with an interior taper or friction fit so that the lineals are slip fit into the fittings, without the use of solvents or adhesives, to form the foundation drain system. The lineals and vertical L and Tee couplings are inserted into the tapered fittings to form a friction fit to prevent the leakage of concrete into the piping. 4.0 DESIGN AND INSTALLATION The Form-A-Drain system must be installed in accordance with the manufacturer's published installation instructions and this report. A copy of the manufacturer s published installation instructions must be available at the job site at all times during installation. ICC-ES Evaluation Reports are not to be construed as representing aesthetics or any other attributes not specifically addressed, nor are they to be construed as an endorsement of the subject of the report or a recommendation for its use. There is no warranty by ICC Evaluation Service, LLC, express or implied, as to any finding or other matter in this report, or as to any product covered by the report. Copyright 2018 ICC Evaluation Service, LLC. All rights reserved. Page 1 of 4

ESR-3964 Most Widely Accepted and Trusted Page 2 of 4 See Table 1 for infiltration rates of water into the Form-A- Drain lineals. The Form-A-Drain lineal, gravel or crushed stone, and approved filter membrane material must be placed in accordance with IBC Section 1805.4 or IRC Section R405.1, as applicable. Discharge of the Form-A-Drain system must be in accordance with IBC Section 1805.4.3 or IRC Section R405.1, as applicable. 5.0 CONDITIONS OF USE The Form-A-Drain Foundation Footing Form and Drainage System described in this report complies with, or is a suitable alternative to what is specified in, those codes listed in Section 1.0 of this report, subject to the following conditions: 5.1 Installation must comply with this report, the manufacturer s published installation instructions and the applicable code. In the event of a conflict between the manufacturer s published installation instructions and this report, this report governs. 5.2 Whenever crossovers are provided through foundations, plans and calculations must be submitted to the code official at the time of permit application, demonstrating the structural integrity of the foundation has been maintained. The calculations and drawings must be prepared and sealed by a registered design professional where required by the statutes of the jurisdiction in which the project is to be constructed. 6.0 EVIDENCE SUBMITTED 6.1 Manufacturer s published descriptive literature and installation instructions. 6.2 Engineering calculations addressing water infiltration into the Form-A-Drain system. 6.3 Quality documentation in accordance with ICC-ES Acceptance Criteria for Quality Documentation (AC10). 7.0 IDENTIFICATION Form-A-Drain system components must be labeled with the manufacturer s name and this evaluation report number (ESR-3964). TABLE 1 DRAIN INFILTRATION RATES WATER INFILTRATION RATE PER FOOT OF LINEAL 1 (gal/min) Feet of Head 0.5 1.0 1.5 2.0 2.5 3.0 17.5 24.7 30.3 34.9 39.1 42.8 For SI: 1 inch = 25.4 mm, 1 gallon/minute = 0.0631 liter/second 1 The slot pattern (number of slots, size of slots, and shape of slots) is the same on all sizes; therefore, the infiltration rate is the same for all sizes of the drain.

ESR-3964 Most Widely Accepted and Trusted Page 3 of 4 FIGURE 1 SYSTEM SCHEMATIC NOTE: For illustrative purposes only FIGURE 2 INSTALLATION CROSS SECTION Note: For illustrative purposes only

ESR-3964 Most Widely Accepted and Trusted Page 4 of 4 FIGURE 3 SYSTEM COMPONENTS