Commercial Medical Marijuana Operation Design Guidelines

Similar documents
(d) Metal buildings used for industrial uses are not exempt from additional landscape standards as required in Section (e).

DESIGN GUIDELINES FOR MULTI FAMILY AND ATTACHED SINGLE FAMILY INFILL HOUSING

With Illustrated Guidelines for Implementation

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Bonaventure of Thornton Senior Living Planned Developed Standards October 23, 2015 Revised: December 9, A. Statement of Intent

Corridor Residential Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Corridor Residential Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

CHAPTER MFR-14 Multi-Family Residential. 3,000 Square Foot Minimum Lots

Corridor Residential Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Architectural Standards

SECTION LARGE SCALE COMMERCIAL RETAIL DESIGN STANDARDS

Corridor Commercial Traditional District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Permitted Uses. Permitted uses in the "LI" District include: Offices (except contractors offices), office-showrooms, and office-warehouses

A PPEARANCE REVIEW BOARD

CHAPTER 15 - "M2" HEAVY INDUSTRIAL DISTRICT

DESIGN REVIEW COMMITTEE AGENDA ITEM

MISTLETOE HEIGHTS HISTORIC AND CULTURAL DISTRICT GUIDELINES

CITY of CARPINTERIA, CALIFORNIA

Neighborhood Suburban Multi-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Corridor Commercial Suburban District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

EXHIBIT V G LEHIGH ACRES DESIGN STANDARDS CHECKLIST LEHIGH ACRES PLANNING COMMUNITY

A. Applicability and Review Authority.

ARTICLE 13 SITE PLAN REVIEW

CHAPTER R-6,000 Single-Family Residential. 6,000 Square Foot Minimum Lots

Neighborhood Suburban Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

MIAMI 21 ARTICLE 5. SPECIFIC TO ZONES PUBLIC HEARING-FIRST READING TABLE OF CONTENTS

C H A P T E R PRECISE DEVELOPMENT (PD) COMBINING DISTRICT

Stanford Industrial Park. Design Guidelines

ARTICLE EIGHT Unified Development Code Adopted: December 4, 2008

Central Valley Research and Technology Business Park

Administrative Item Conditional Building and Site Design Review. 360 West 300 South PLNPCM February 26, 2014

B-2 COMMUNITY COMMERCIAL BUSINESS DISTRICT. Uses allowed in the B-2 Community Commercial Business District are subject to the following conditions:

Link to APPENDIX Title Page. Appendices

PARKING GARAGE LDC ARTICLE VIII. Design Standards City of Oviedo

Architectural Standards

ARCHITECTURAL SUGGESTED DESIGN GUIDELINES FOR PEGASUS AIRPARK

5.1 Purpose. 5.2 Fencina and yard ~nclosllres

MULTI FAMILY AND SINGLE FAMILY ATTACHED DESIGN GUIDELINES CITY OF ROCK HILL, SOUTH CAROLINA

DOUGLAS COUNTY ZONING RESOLUTION Section 14 GI - General Industrial District 3/10/99. -Section Contents-

PLANNING COMMISSION WORK SESSION APRIL 2, :00 P.M. Town Board Chambers, 301 Walnut Street, Windsor, CO 80550

Chapter 5 FENCES IN COMMERCIAL ZONES

ARTICLE 987. PD 987. PD 987 was established by Ordinance No , passed by the Dallas City Council on June 14, (Ord.

2. Exemptions. The following uses shall be exempt from the requirements of this section: a. New and expanded Agricultural sites and structures.

Summary of Common Design Guidelines

Light Industrial (I)

PERMITTED USES: Within the MX Mixed Use District the following uses are permitted:

RESIDENTIAL DESIGN REVIEW APPLICATION

For Duplicate Buildings and Buildings of 60,000 Gross Square Feet or Greater

TEMPORARY STRUCTURES AND OUTDOOR STORAGE SECTION City of Maryland Heights ZONING CODE

Fence and Wall Requirements

BUILDING DESIGN STANDARDS

DESIGN REVIEW COMMITTEE AGENDA ITEM

Fences, Wall and Hedge Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

Section 4.05 Architectural and Site Design Requirements. [Amended Ordinance # 09-04]

A PPEARANCE REVIEW BOARD

INTENT OBJECTIVES HISTORIC DESIGNATIONS

SIGNAGE. Raymond Design Guidelines Signs

4040 MANUFACTURING (M)

Sec Development Standards in P-N-T Districts.

RZ-1 LEGEND FUTURE ACCESS TO ALIGN W/ EXISTING HARRIS COVE DRIVE FUTURE ACCESS TO ALIGN WITH PROPOSED ACCESS OPPOSITE COX ROAD

COMMUNITY APPEARANCE STANDARDS

SECTION 5 EXCEPTIONS AND MODIFICATIONS

CITY OF HARTFORD GUIDELINES FOR SOLAR ON HISTORIC PROPERTIES SECTIONS ADOPTED 2017

4) Garage placement must be in compliance with Sec. 6.3.G.2 below.

PART II CODE OF ORDINANCES Chapter 114 ZONING ARTICLE II. DISTRICT REGULATIONS

Urban Design Overlay

Corridor Design Standards

ORDINANCE NO Ordinance styled:

Chapter 10 SUPPLEMENTARY USES

Architectural Review Standards and Guidelines

Public and Institutional Development

HIGHLAND CROSSROADS DESIGN GUIDELINES ARCHITECTURAL AND SITE DEVELOPMENT GUIDELINES

11.0 Commercial Infill


PART 6 GENERAL REGULATIONS

Section , Article 4 of the Zoning Ordinance December 14, 2012 Page 1 of 8

Commercial Development

VILLAGE OF HOLMEN LA CROSSE COUNTY, WISCONSIN ORDINANCE AN ORDINANCE CREATING ARTICLE XVI OF THE CODE OF THE VILLAGE OF HOLMEN

Design Guidelines Outline for the West Boulevard Historic District

Neighborhood Traditional Single-Family District Regulations City of St. Petersburg City Code Chapter 16, Land Development Regulations

ARTICLE 623. PD 623. PD 623 was established by Ordinance No , passed by the Dallas City Council on September 25, (Ord.

SITE PLAN AND ARCHITECTURAL REVIEW APPLICATION

MASONRY, ARCHITECTURE DESIGN AND BUILDING STANDARDS

Commercial Tax Abatement

MIAMI 21 AS ADOPTED JANUARY 2011

Village of Greendale. Building Board Principals and Standards of Review

DESIGN REVIEW COMMITTEE AGENDA ITEM

Chapter WALLS AND FENCES

OLDE WEST CHESTER ARCHITECTURAL ADVISORY GUIDELINES

Muirfield Association, Inc.

1A-300 SCREENING AND BUFFERING REQUIREMENTS

José Nuño, Chairman. Exhibit A Amendments to Table

ATTACHMENT B THE COMMUNITY REDEVELOPMENT AGENCY OF THE CITY OF LOS ANGELES, CA RESOLUTION NO._6022_

(DC2) SITE SPECIFIC DEVELOPMENT CONTROL PROVISION

architecture for multi-family development

SUGGESTED GUIDELINES Design Review Board

III. VILLAGE CORE A. LOCATION AND DESCRIPTION

AC-OL (1), Court House Square District. AC-OL (2), Downtown Perimeter District

SUGGESTED GUIDELINES Design Review Board

Transcription:

City of Coalinga Community Development Department Commercial Medical Marijuana Operation Design Guidelines The provisions set forth in this document identify the desired level of design quality for all Commercial Medical Marijuana Operations (CMMOs) in the City of Coalinga. All CMMOs shall be located within the Light Manufacturing/Business (MBL) District. The following CMMO Design Guidelines shall be in addition to the City of Coalinga s MBL standards and requirements (Title 9, Chapter 2, Article 4 of the Coalinga Municipal Code). The CMMO Guidelines are intended for the Community Development Department to use in evaluating project applications. Existing Development The following guidelines shall be applied for CMMOs within existing development: 1.0 Security Measures 1.1 Ornamental steel fencing is recommended instead of chain link fencing and/or barbed wire fencing. The use of constatine/razer/barbed wire is prohibited. NOT 1.2 Electronic surveillance equipment and alarm hardware shall be as invisible and unobtrusive as possible.

Page 2 1.3 Poles and fixtures should be designed to be architecturally compatible with structures and lighting on adjacent properties. 1.4 Poles and fixtures shall be compatible with all other fixtures on site. 1.5 Select and locate all lighting fixtures to shield or confine light spread within a site s boundaries. 1.6 To facilitate security, specify lighting levels that are adequate for visibility, but not overly bright. All building entrances should be well illuminated. 1.7 Use metal halide or other white light fixtures. High pressure sodium is not allowed in any application. 1.8 Maximum height of all poles within landscaped and plaza areas is 20 feet, measured from grade. Pole pedestals (bases) are limited to a minimum of eightinches in height. 1.9 Decorative light fixtures, which are appropriately shielded, and provide visual interest, are allowed. New Development In addition to the guidelines for CMMOs within existing development, new CMMO developments in the City of Coalinga shall keep in mind the following guidelines: 2.0 Building Size and Scale 2.1 Ensure that new buildings are compatible in scale, massing, style, and/or architectural materials with existing structures in the surrounding neighborhood. 2.2 Articulate building forms and elevations to create varied rooflines, building shapes, and patterns of shade and shadow. Standard box type industrial steel buildings are discouraged. 2.3 Situate buildings on the site so they are oriented to maximize daylighting opportunities and harvest natural light within interior work spaces. Also utilize opportunities to provide operable clerestory windows to allow for ventilation and indirect lighting.

Page 3 Building situated to maximize daytime lighting NOT Blank wall is a missed opportunity to provide daylighting 3.0 Entrances 3.1 Provide a logical sequence of entry and arrival as part of the site s design. Special entry treatments such as stamped or colored concrete and special planting and signage can be used to enhance entries and guide pedestrians.

Page 4 3.2 Entries should be designed according to simple and harmonious proportions in relationship to the overall size and scale of the building. Ensure that pedestrian entries are properly sized to provide shelter year round. 3.3 Ensure that the main entrance and entry approach can accommodate persons of all mobility levels. 3.4 Promote pedestrian activity by placing entrances at grade level or slightly above, and unobstructed from view from the public right of way. Avoid sunken entryways below street level. Unobstructed and architecturally coherent entry Visible and attractive stairs NOT Harsh security measures Architecturally incoherent entry Barred entry

Page 5 4.0 Site Planning 4.1 Create height and visual transitions between industrial districts and adjacent commercial and residential neighborhoods. Stepping back upper floors of industrial structures to match those of adjacent commercial or residential structures, and plant trees, shrubs, and vines to screen outdoor storage and odor or noise generating functions of industrial uses. Adequate landscaping buffer softens transition between uses NOT Poor screening transition between manufacturing and residential uses

Page 6 4.2 CMMOs are required to incorporate on site parking to minimize negative impacts on the street and adjacent uses. 4.3 Provide site access, parking, and circulation that is arranged in a logical and safe manner for pedestrians and vehicles; 4.4 Views of parking areas from the street shall be discouraged. Landscaping, low walls and shrubs, and berming shall be utilized to screen parking areas. 4.5 Chain link fencing with or without wood slatting is not an acceptable screen material. 5.0 Site Utilities and Mechanical Equipment 5.1 Utility and mechanical equipment (e.g. electric and gas meters, electrical panels, and junction boxes) shall be screened from the view of public streets and neighboring properties. 5.2 Mechanical equipment shall be concealed by building elements that were designed as an integral part of the building design, unless local utilities prohibit this practice. 5.3 Mechanical equipment shall not cause adjacent occupants and activities to be subject to noise that is disturbing by virtue of its volume or nature. 5.4 Roof top mounted equipment shall be screened from the street and other buildings on all four sides by a structural feature that is an integral part of the building s architectural design. 5.5 Roof top equipment shall be grouped and located so that it is not visible from the line of sight angle from the pedestrian right of way. 5.6 Rooftop equipment shall be screened from view from a taller building, adjacent residential structures or adjacent elevated roadways. Refuse storage areas that are visible from upper stories shall be designed so that an opaque or semi opaque horizontal cover/screen reduces unsightly views. 5.7 Where utility, service, garbage and/or loading areas face adjacent public streets and/or open space, these facilities are to be thoroughly screened through the use of landscaping, low walls or earth berming integrated with plant material. (Location and screening must be shown on plans.)

Page 7 6.0 Trash and Storage Areas 6.1 Whenever possible, trash enclosures shall be architecturally integrated into the design of the structure, at the rear of the building. 6.2 Trash enclosures shall provide adequate space for recycling. 6.3 Trash enclosures shall be located away from sensitive uses, such as residences or schools, to minimize nuisance for adjacent property owners. 6.4 Trash enclosures shall be constructed with masonry walls, metal doors, have overhead coverings, and shall be architecturally compatible with the project. 6.5 All trash enclosures and garbage bins shall be screened from public view to the greatest extent possible. 6.6 Landscaping shall be used around trash enclosures to providing screening and deter graffiti.