Signature Sports Flooring (Economy I Series Wall Padding) WPE1-XX Safety Wall Padding

Similar documents
LOWER MACUNGIE TOWNSHIP COMMUNITY CENTER ADDITIONS AND RENOVATIONS

A. This section includes pre-finished Higuera Hardwoods bamboo flooring and accessories for floors and stairs.

A. This Section includes the following: 1. Bulletproof modular counter with Security Glazing in following levels:

SECTION SOUND-ABSORPTIVE PANELS

ACOUSTICAL WALL TREATMENT SECTION 09840

SECTION SOUND-ABSORPTIVE PANELS

SECTION PREFABRICATED SHOWER COMPARTMENTS

Section Wood Veneer Ceiling Tiles Micro Perforated

SECTION WALL AND DOOR PROTECTION

Section SoundPly LR M25 Acoustic Ceiling Panels

SECTION LINEAR WOOD CEILINGS

SECTION STRUCTURAL INSULATED PANELS

Guide Specifications Section Wood Ceiling Coffers

COMPOSITESIDING

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

Product Guide Specification

ADDENDUM NO. 5. April 9, 2014

SECTION SERIES ALL GLASS ENTRANCES

Section Wood Veneer Ceiling Planks Linear

SECTION VINYL-COATED FABRIC WALL COVERINGS

Guide Specification for: FABRI TRAK PVC FREE Stretched Fabric Wall System Section [ ] or Section [ ]

SECTION DEMOUNTABLE WALLS SKY WALLS - STRATUS SYSTEM

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 12/12/2018

SECTION SOLID SURFACE FABRICATIONS

Product Guide Specification

Section HIGH-TENSION Stretched-Fabric Wall Systems SoftWalls, Inc.

Series 3000 Pocket Doors

TotTurf EPDM Product Specification

INTERIOR FINISHES CHAPTER 8

Specifications for LiteWeight Wall Padding: LW7007

INTERIOR FINISHES CHAPTER 8

Section SoundPly RF M25 Acoustic Wall Panels

SECTION DEMOUNTABLE PARTITIONS

A. Product Data: Identify thermal conductivity, thickness, and jackets (both factory and field applied, if any), for each type of product indicated.

SECTION PANEL SIGNAGE PART 1 - GENERAL 1.1 RELATED DOCUMENTS

SECTION POLYPROPYLENE FABRIC WALL COVERING

SECTION MULTI-USE COMPOSITE ALUMINUM PANELS

University of New Hampshire Scholars' Repository

University of New Hampshire Scholars' Repository

SPECIFICATIONS PORTER No PORTABLE BASKETBALL BACKSTOP SYSTEM (FOR INDOOR OR OUTDOOR USE) WITH FAN FIBERGLASS BACKBOARD

Product Guide Specification

PRODUCT SPECIFICATIONS - SERIES 1090

SECTION Paper-Composite Countertops PART 1: GENERAL

INTERIOR FINISHES CHAPTER 8

TotTurf Pigmented Poured in Place Product Specifications TOTTURF a PLAYCORE company July 2011

Phenolic Exterior Wall Cladding

WC SERIES SPECIFICATION SECTION ACCESS FLOORING

SECTION ALL GLASS ENTRANCES. 1. Lock cylinders for tempered glass entrance doors are specified in Division 8 section Finished Hardware.

INTERIOR FINISHES CHAPTER 8 SECTION 801 GENERAL

DSC BUILDING 1200 ALTERATIONS OCTOBER 2011 SECTION DUCT INSULATION

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Product Guide Specification

E. Popcorn or other spray applied textures on ceiling or walls are not acceptable.

Acoustic Surfaces. Horizontal Bar

Division 9 Resilient Athletic Flooring

SECTION DRY ERASE COATING (IdeaPaint CREATE Black and White) A. Section Gypsum Board Assemblies; gypsum board substrate.

SECTION TOILET COMPARTMENTS. A. Section Metal Fabrications: Concealed steel support members.

B. LEED Submittals (Projects authorized for LEED certification only)

SECTION ACCORDION FOLDING PARTITIONS

Northpointe Renovation EPN #1701 F/A Prroject #17027 September 8, 2017

RESILIENT ACCESSORIES

Product Guide Specification

ENVELOPE The Ultimate In Performance In A Dry-Joint System RAINSCREEN (RS) SYSTEM TECHNICAL MANUAL

PRODUCT SPECIFICATIONS PULTRUDED GRATING AND TREADS SECTION PART 1 GENERAL

High-performance structural cement-bonded particle board (CBPB)

Section Performance Floor Asemblies (Also Dance Floor Assemblies)

SECTION WOOD GYMNASIUM FLOORING

AMBICO Limited Section and WOOD BULLET RESISTANT DOORS AND FRAMES Page 1

Multi-Institutional Academic Health Science & Research Center Evansville, IN

Features. Specifications. VersaShield MBX slashes up to half the total cost with a quick and effective concrete moisture mitigation up to 99.5% RH.

SECTION WOOD GYMNASIUM FLOORING

SECTION SOLID SURFACE COUNTERTOPS. Display hidden notes to specifier. (Don't know how? Click Here)

INTERIOR FINISH, DECORATIVE MATERIALS AND FURNISHINGS

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SECTION FIBERGLASS REINFORCED POLYMER (FRP) PANELS

TotTurf TPV (1-4mm) Product Specification

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

PRODUCTION SPECIFICATIONS INSULATED CONCRETE FORMS

C. Samples: For each door face material, at least 3 by 5 inches (75 by 125 mm) in size, in specified finish.

SECTION FLUSH WOOD DOORS

TotTurf Bonded TotTurf Bonded Poured in Place Product Specifications TOTTURF a PLAYCORE company May 2011

A. This Section includes duct and plenum insulation; accessories and attachments; and sealing compounds.

SECTION TRESPA ATHLON SOLID COMPOSITE PHENOLIC TOILET PARTITIONS. A. Solid composite phenolic toilet compartments and urinal screens.

Spec Master 5/7/ For each product requiring color and texture selection, provide full size samples.

C. Low-Emitting Materials: Provide doors made with adhesives and composite wood products that do not contain urea formaldehyde.

Sustainability Our journey to provide Sustainable furniture solutions

Geometrik Manufacturing Inc.

Section Wood Grille Ceiling Panels

East Central College

Zeager Bros. Inc. Middletown, Pa / Zeager Hardwood Co. Franklin, Ky Revised - August, 2012 by ASC

SPECIFICATIONS ADVANTAGES. For more information on this product or to order samples call or visit our website at builddirect.

Framed Decorative Panel Systems

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

featuring: RR (Rout & Return) Attachment System RS (RainScreen) Attachment System Envelope2000 Metal Composite Material (MCM)

Soundmaster & Modernfold TECHNICAL DATA

HARO SPORTS FLOOR C.S.I. GUIDE SPECIFICATION Helsinki-Gymnasium Floor System 10/2010 SECTION WOOD ATHLETIC FLOORING

SECTION CLIMBING WALLS

Façade Architectural Wall Panel System - Guide Specification 3/11/2017 SECTION FRAMED DECORATIVE PANEL SYSTEMS PART 1 - GENERAL 1.

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

SECTION LAGUNA SERIES TOP HUNG SLIDING DOOR SYSTEM

Transcription:

Signature Sports Flooring (Economy I Series Wall Padding) WPE1-XX Safety Wall Padding A. Basis-of-Design Product: Subject to compliance with requirements. Provide Signature Sports Flooring model WPE1-X X. B. Padded wall wainscot panels designed to be attached in a continuous row; each panel consist of foam filler laminated to OSB wood backing and covered with Class A Flame retardant vinyl coated polyester on full surface, sides, ends, and including all wood edges, vinyl is securely stapled to the back of the OSB backer board. 1. Backer Board: Not less than 7/16-inch- (11-mm-) SFI Certified Responsible Urea Formaldehyde Free recycled composite wood backer board. This portion of the product contributes toward satisfying Credit IEQ 4.4 under LEED 2. Foam Filler: Not less than 2-inch- (50.8-mm-) thick upholstery grade polyurethane foam filler, with a density of 3-lb/ ft3 (48-kg/ m3) x 70 IFD, meeting CAL. TB 117 flame retardant specification 3. Vinyl Covering: 16 -oz. / yd2 (543-g/ m3) Vinyl Coated Polyester - puncture and tear-resistant. CPSC CPSIA - 6P and lead compliant. Phthalates less than.1% and Lead less than 100 ppm. Achieving NFPA- 701 CSFM, and a Class A fire rating under ASTM E-84, with a smoke UV and Anti-Mildew treated. C. Sizing: Standard size panels are 24 inches (60.9 cm) wide x inches high (specify panel height) panel section or as indicated on Drawings. D. Color(s) of vinyl to be selected from manufactures standard color packet E. Corner and Column Pads: Pre-Fabricated / Field Fabricated corner and column pads to be built with materials consistent with standard padding specifications as listed above. F. Installation: Select one of three primary options below. Comply with manufacturers written instructions, Refer to Architects elevation drawings for panel placement. Mount panels no more than 4 above finished floor as recommended in in ASTM, unless otherwise directed. Install wall padding after painting and electrical have been completed use proper wall anchor hardware. 1. Panels to be supplied with a 1-inch- nail margin top and bottom and mounted directly to wall surface.

2. Panels to be supplied with a no nail margins and to be hung on concealed Aluminum Z track supplied by the wall pad manufacturer. 3. Panels to be supplied with a no nail margins and to be mounted to concealed 1-inch- x 3-inch- fir stripping that is attached in 3 continuous horizontal rows to the wall. Panels are affixed to the stripping using a toenail method of nailing. G. Adjusting: 1. Final adjustment of panels to insure a smooth finished appearance 2. Clean and remove any debris from the working area 3. Spot clean panels as may be necessary

Signature Sports Flooring (Economy II Series Wall Padding) WPE2-XX Safety Wall Padding A. Basis-of-Design Product: Subject to compliance with requirements. Provide Signature Sports Flooring model WPE2-XX. B. Padded wall wainscot panels designed to be attached in a continuous row; each panel consist of foam filler laminated to OSB wood backing and covered with Class A Flame retardant vinyl coated polyester on full surface, sides, ends, and including all wood edges, vinyl is securely stapled to the back of the OSB backer board. 1. Backer Board: Not less than 7/16-inch- (11-mm-) SFI Certified Responsible Urea Formaldehyde Free recycled composite wood backer board. This portion of the product contributes toward satisfying Credit IEQ 4.4 under LEED 2. Foam Filler: Not less than 2-inch- (50.8-mm-) thick hypoallergenic bonded urethane foam filler with a density of 6-lb/ ft3 (96-kg/ m3). Meets the ASTM standard 2440-04 Impact attenuation where the panel has achieved ratings below 1000 HIC and 200 g max. 100% pre-consumer recycled and 100% post-consumer recyclable. This portion of the product contributes toward satisfying Credit MR 4 under LEED 3. Vinyl Covering: 16 -oz. / yd2 (543-g/ m3) Vinyl Coated Polyester - puncture and tear-resistant. CPSC CPSIA - 6P and lead compliant. Phthalates less than.1% and Lead less than 100 ppm. Achieving NFPA- 701 CSFM, and a Class A fire rating under ASTM E-84, with a smoke UV and Anti-Mildew treated. C. Sizing: Standard size panels are 24 inches (60.9 cm) wide x inches high (specify panel height) panel section or as indicated on Drawings. D. Color(s) of vinyl to be selected from manufactures standard color packet E. Composite Testing: Manufacturer must warrant that a composite panel built with similar materials was tested and passes for ASTM standard 2440-04 Impact attenuation where the panel has achieved ratings below 1000 HIC and 200 g max. Manufacturer must also warrant that foam filler is hypoallergenic, produced using 100% recycled urethane, and is 100% post-consumer recyclable. F. Corner and Column Pads: Pre-Fabricated / Field Fabricated corner and column pads to be built with materials consistent with standard padding specifications as listed above.

G. Installation: Select one of three primary options below. Comply with manufacturers written instructions, Refer to Architects elevation drawings for panel placement. Mount panels no more than 4 above finished floor as recommended in in ASTM, unless otherwise directed. Install wall padding after painting and electrical have been completed use proper wall anchor hardware. 1. Panels to be supplied with a 1-inch- nail margin top and bottom and mounted directly to wall surface. 2. Panels to be supplied with a no nail margins and to be hung on concealed Aluminum Z track supplied by the wall pad manufacturer. 3. Panels to be supplied with a no nail margins and to be mounted to concealed 1-inch- x 3-inch- fir stripping that is attached in 3 continuous horizontal rows to the wall. Panels are affixed to the stripping using a toenail method of nailing. H. Adjusting: 1. Final adjustment of panels to insure a smooth finished appearance 2. Clean and remove any debris from the working area 3. Spot clean panels as may be necessary

Signature Sports Flooring (Premium I Series Wall Padding) WPP1-XX Safety Wall Padding A. Basis-of-Design Product: Subject to compliance with requirements. Provide Signature Sports Flooring model WPP1-X X. B. Padded wall wainscot panels designed to be attached in a continuous row; each panel consist of foam filler laminated to OSB wood backing and covered with Class A Flame retardant vinyl coated polyester on full surface, sides, ends, and including all wood edges, vinyl is securely stapled to the back of the OSB backer board. 1. Backer Board: Not less than 7/16-inch- (11-mm-) SFI Certified Responsible Urea Formaldehyde Free recycled composite wood backer board. This portion of the product contributes toward satisfying Credit IEQ 4.4 under LEED 2. Foam Filler: Not less than 2-inch- (50.8-mm-) thick, Low Smoke Polychloroprene compound foam filler with a density of 6-lb/ ft3. (96-kg/ m3). Achieves Class A fire rating under ASTM E-84, with a smoke 3. Vinyl Covering: 16 -oz. / yd2 (543-g/ m3) Vinyl Coated Polyester - puncture and tear-resistant. CPSC CPSIA - 6P and lead compliant. Phthalates less than.1% and Lead less than 100 ppm. Achieving NFPA- 701 CSFM, and a Class A fire rating under ASTM E-84, with a smoke UV and Anti-Mildew treated. C. Sizing: Standard size panels are 24 inches (60.9 cm) wide x inches high (specify panel height) panel section or as indicated on Drawings. D. Color(s) of vinyl to be selected from manufactures standard color packet E. Composite Testing: Manufacturer must warrant that a composite panel built with similar materials was tested and achieves an overall Class A fire rating under ASTM Standard E-84, with a smoke developed index of 450 or less and a flame spread index of 25 or less. F. Corner and Column Pads: Pre-Fabricated / Field Fabricated corner and column pads to be built with materials consistent with standard padding specifications as listed above. G. Installation: Select one of three primary options below. Comply with manufacturers written instructions, Refer to Architects elevation drawings for

panel placement. Mount panels no more than 4 above finished floor as recommended in in ASTM, unless otherwise directed. Install wall padding after painting and electrical have been completed use proper wall anchor hardware. 1. Panels to be supplied with a 1-inch- nail margin top and bottom and mounted directly to wall surface. 2. Panels to be supplied with a no nail margins and to be hung on concealed Aluminum Z track supplied by the wall pad manufacturer. 3. Panels to be supplied with a no nail margins and to be mounted to concealed 1-inch- x 3-inch- fir stripping that is attached in 3 continuous horizontal rows to the wall. Panels are affixed to the stripping using a toenail method of nailing. H. Adjusting: 1. Final adjustment of panels to insure a smooth finished appearance 2. Clean and remove any debris from the working area 3. Spot clean panels as may be necessary

Signature Sports Flooring (Premium II Series Wall Padding) WPP2-XX Safety Wall Padding A. Basis-of-Design Product: Subject to compliance with requirements. Provide Signature Sports Flooring model WPP2-X X. B. Padded wall wainscot panels designed to be attached in a continuous row; each panel consist of foam filler laminated to OSB wood backing and covered with Class A Flame retardant vinyl coated polyester on full surface, sides, ends, and including all wood edges, vinyl is securely stapled to the back of the OSB backer board. 1. Backer Board: Not less than 7/16-inch- (11-mm-) SFI Certified Responsible Urea Formaldehyde Free recycled composite wood backer board. This portion of the product contributes toward satisfying Credit IEQ 4.4 under LEED 2. Foam Filler: Not less than 2-inch- (50.8-mm-) thick, Low Smoke Polychloroprene compound foam filler with a density of 6-lb/ ft3. (96-kg/ m3). Achieves Class A fire rating under ASTM E-84, with a smoke 3. Vinyl Covering: 16 -oz. / yd2 (543-g/ m3) Vinyl Coated Polyester - puncture and tear-resistant. CPSC CPSIA - 6P and lead compliant. Phthalates less than.1% and Lead less than 100 ppm. Achieving NFPA- 701 CSFM, and a Class A fire rating under ASTM E-84, with a smoke UV and Anti-Mildew treated. C. Sizing: Standard size panels are 24 inches (60.9 cm) wide x inches high (specify panel height) panel section or as indicated on Drawings. D. Color(s) of vinyl to be selected from manufactures standard color packet E. Composite Testing: Manufacturer must warrant that a composite panel built with similar materials was tested and achieves an overall Class A fire rating under ASTM Standard E-84, with a smoke developed index of 450 or less and a flame spread index of 25 or less. F. Corner and Column Pads: Pre-Fabricated / Field Fabricated corner and column pads to be built with materials consistent with standard padding specifications as listed above. G. Installation: Select one of three primary options below. Comply with manufacturers written instructions, Refer to Architects elevation drawings for

panel placement. Mount panels no more than 4 above finished floor as recommended in in ASTM, unless otherwise directed. Install wall padding after painting and electrical have been completed use proper wall anchor hardware. 1. Panels to be supplied with a 1-inch- nail margin top and bottom and mounted directly to wall surface. 2. Panels to be supplied with a no nail margins and to be hung on concealed Aluminum Z track supplied by the wall pad manufacturer. 3. Panels to be supplied with a no nail margins and to be mounted to concealed 1-inch- x 3-inch- fir stripping that is attached in 3 continuous horizontal rows to the wall. Panels are affixed to the stripping using a toenail method of nailing. H. Adjusting: 1. Final adjustment of panels to insure a smooth finished appearance 2. Clean and remove any debris from the working area 3. Spot clean panels as may be necessary