PM Compliance Options for MACT and MATS Rules. Ed McCall PCME

Similar documents
Calibration of Light Scatter PM-CEMs to Satisfy PS-11 on Wet Stacks in Coal Fired EGUs

Particulate CEMs for Wet and Dry FGD applications. By William Averdieck, Managing Director, PCME Ltd, UK

Energy Production Systems Engineering

Particulate Matter (PM) CEMS

A Comparison of Proposed PM CPMS Limits

Dry Sorbent Injection and Modeling for Acid Gas Emissions Control. Lew Benson McIlvaine Hot Topic Hour June 7, 2012

Process Optimization & Plant Safety

CEMS for Measurement of Ammonia, SO 3, and Low Level NOx

Particulate and Opacity Control - Program 76

EMO August 1, Bobby I.T. Chen Client Program Manager

BetaGuard PM Particulate Monitoring for Portland Cement MACT

John Downs Environmental Manager, B&W PGG, KVB-Enertec Products. January 29, 2015

: Industrial Boiler MACT: CEM Requirements. Dan Kietzer: SICK Process Automation

Coal Fired Boiler Optimization and the Impact on Emission Control Devices

ABB Measurement & Analytics Monitoring cement plant stack emissions using FTIR

Update on ICI Boiler MACT

Continuous Emissions Monitoring - Program 77

"MARAMA/ICAC Mercury CEMS Webinar" Tuesday, July 26, 2011

Integrating ADAir Mixer Technology to Optimize System Performance with DSI Applications

BOILER MACT 40 CFR 63 DDDDD

TruePeak TDLS200. NH 3 Slip Measurement. <Document Number> Copyright Yokogawa Electric Corporation <date/time>

Greenhouse Gas Regulation (new Federal)

Improvements of the EGTEI Cost Calculation Tool for Emission Reduction Measures in LCPs

Boiler MACT & Related Rules. Western Regional Boiler Association 45 th Annual Meeting Portland, Oregon March 14, 2013

GOVERNMENT of PUERTO RICO OFFICE OF THE GOVERNOR ENVIRONMENTAL QUALITY BOARD

Up gradation of Boilers to Implement New Pollution Norms

Cross-effects and total gas clean-up system lay-out

Continuous Emissions Monitoring in Support of the Cement MACT

Commercial and Industrial Solid Waste Incinerator (CISWI) Rules Final Reconsidered Rules Requirements Summary

Monitoring cement plant stack emissions using FTIR

CAM does have exemptions for certain emission units as follows: Page 1 of 8

Activated Carbon Injection for Mercury Control on Industrial Coal-Fired Boilers

Control Device Technology

World Water & Environmetal Resources Congress 2004 Salt Lake City June New Air Quality Requirements for Facilities with Boilers

Mercury Measurements and Control

DAILY LIFE of CEMS QA & PM

Presentation Overview Air Quality Regulations Evolution in the U.S. Summary of Current NESHAPS Regulations Mercury Emissions Control and Measurement T

FINE PARTICULATE COLLECTION USING DRY ELECTROSTATIC PRECIPITATORS

Reducing the Cost of Compliance and Improving Plant Operations for Coal-Fired Boilers

Industrial Boiler MACT Rule Impact and Control Options for Mercury and Dioxins/Furans

Particulate and Emission Monitoring Solutions

Biomass Boiler Emission Abatement Technologies. Simon Wakefield

Fuel Quality and MATS for Coal- Fired Plants: The Ripple Effect

Worldwide Pollution Control Association

BetaGuard PM Particulate Monitor Discussion. BetaGuard PM Background and Technical Information. BetaGuard PM CEM. MARAMA PM CEMS Webinar

AQCS (Air Quality Control System) for Thermal Power Plants Capable of Responding to Wide Range of Coal Properties and Regulations

Technology Advancement and Standards for Biomass Fuel to Energy Conversion. Topics Covered

Evaporative Gas Cooling and Emissions Control Solutions

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance

Local Impacts of Mercury from Coal-Fired Power Plants

GEOENERGY WET ESPS FOR BOILER MACT APPLICATIONS

Worldwide Pollution Control Association

Control Options For FPI Boilers to Meet Proposed Boiler MACT Limits

EPA Regulation: Utility MACT Proposal

COMAR Amendments and Regulation.12 Standards for Biomass Fuel-Burning Equipment Equal to or Greater Than 350,000 Btu/hr

Sorbents Evaluation Testing Facilities. 95% removal efficiency or an emission standard of lbs/gw h by 2012, while

SCR for NO x Control in Coal-fired Power Plants

Sampling Technology for Extractive CEMS & Maintenance Issues of CEMS Sanjeev Rai Perma Pure Aug 9, 2016

Continuous Mercury Monitoring at Cement Plant

CISWI and solid-waste-identification rules

PC MACT Updates. Cemtek Environmental Emissions Monitoring Seminar Costa Mesa, CA September 28, Vineet Masuraha Trinity Consultants Irvine, CA

Worldwide Pollution Control Association

EPRI Electrostatic Precipitator Research. Bruce Scherer Program 76, Opacity & Particulate Control Project Manager

A G. The Avogadro Group, LLC. Air Quality Consulting and Source Emissions Testing

FIRST APPLICATION OF BABCOCK-HITACHI K.K. LOW SO 2 TO SO 3 OXIDATION CATALYST AT THE IPL PETERSBURG GENERATION STATION

FACT SHEET MERCURY AND AIR TOXICS STANDARDS FOR POWER PLANTS

Longview Power- An Advanced Supercritical Coal Plant

Gas Flow How to Improve It to Enhance ESP, Boiler, FGD, SCR, SNCR Performance

Fluid Bed Scrubbing TECHNOLOGY

The Value Proposition of Circulating Fluidized Bed Scrubbing Technology. Robert Giglio Foster Wheeler Global Power Group

Particulate and Opacity Control - Program 76

Controlling Mercury Emissions from Coal-Fired Power Plants

Uppgradering av rökgasreningssystem

POWER PLANT AIR QUALITY CONTROL and FLY ASH QUALITY & AVAILABILITY

World Pollution Control Association

Gas Suspension Absorber

MERCURY CONTROL WITH FABRIC FILTERS FROM COAL-FIRED BOILERS

PPC specializes in maximum efficiency air pollution control equipment using a variety of different

ESP and Fabric Filter Considerations for Meeting Environmental Regulations: IED, LCP and WI BREF

GAS ANALYZERS. Digital Manometer

EPA EMISSION RULES - BOILERS

Customized Solutions for Environmental Compliance. Combining proven experience, technology and reliable performance for our customers

ABSTRACT. Electrostatic precipitators (ESPs), which are particulate collectors, are now used as part

Control Technology Options for Boiler MACT and CISWI Compliance

Hot Gas Filters for Control of Emissions to Atmosphere

W P C A. Worldwide Pollution Control Association. WPCA-Duke Energy FF/HAPS Seminar October 12-13, Visit our website at

GE Power. Smarter. Cleaner. Industry. Iron & Steel 2017 STEAM POWER SYSTEMS INDUSTRY PRODUCT CATALOG

PM spiking and PS-11 Testing for PM Monitor Calibrations

NOx CONTROL FOR HIGH ASH COAL-FIRED PLANT 12 TH E C C R I A, 5-7 S E P T E M B E R , C A R D I F F, UK

CEM. Continuous Emission Monitoring Systems NACT 221. Course Overview. National Air Compliance Training. CEM implementing regulations

Worldwide Pollution Control Association

Particulate and Opacity Control - Program 76

Mercury Emissions Control from Existing Utility and Industrial Boilers

Worldwide Pollution Control Association. August 3-4, 2010

Evaluation of Mercury Control Strategies in the Presence of SO 3 Using the MerSim TM Model. Brydger Van Otten, Bradley Adams

Mercury and SO3 Mitigation Issues for Scrubber Technology

Worldwide Pollution Control Association

The Growth of Dry Sorbent Injection (DSI) and the impact on Coal Combustion Residue

Duke Energy Seminar September 3 5, 2008 Concord, NC

Transcription:

PM Compliance Options for MACT and MATS Rules Ed McCall PCME 1

First Some Definitions: PM- CEM, PM-CPMS and BLDs PM-CEM (PM- Continuous Emission Monitor) PM-CPMS (PM-Continuous Parametric Monitoring System) Forward scatter/ Beta or mass CEM (for wet and dry processes) PM-CEM: Calibration in mg/m 3 PM-CPMS: Simpler calibration (Operating Limit) BLD: Bag Leak Detector Provides trend of emissions Automatic self-checks save end user doing manual drift checks Often required if using Fabric Filter (FF) 2

HAP Surrogates & the MACT Rules Non-mercury metals and the many non-dioxin/furan organic HAP s are difficult to measure with continuous monitors. Instead, easily measured pollutants that correlate with HAP s are substituted as surrogates. Two types of particulate matter (PM) Filterable : Solid phase in stack Filterable PM is a surrogate for non-mercury hazardous metals (arsenic, beryllium, cadmium, chromium, manganese, nickel). Condensable: Gas phase in stack. Forms PM after reacting in atmosphere. Selenium correlates somewhat with condensable PM (Se in gas phase in stack - forms PM after cooling). Condensable PM is difficult to measure continuously & with reference methods so only solid phase PM is used. 3

Portland Cement MACT Appeals to CAA Section 112 to reduce HAP s emissions from Portland Cement kilns via Maximum Achievable Control Technology (MACT) Lowers PM, mercury and HCL limits Requires PM CEMS / CPMS (dry stack continuous particulate monitors) PM limits (30 day rolling averages) Existing kilns = 0.07 lbs/ton clinker (~10 mg/am^3) New kilns = 0.02 lbs/ton clinker (~3mg/Am^3) Clinker Cooler Stack must have PM CEMS / CPMS Bag houses (fabric filters) need Bag Leak Detector Need stack flow monitor due to plant output-based PM units Technologies of interest for stack flow include Ultrasonic time-of-flight Hot wire anemometer Pitot tube PCME 181 PCME STACKFLØW 400 4

MATS Rule Mercury and Air Toxics Standard (a.k.a. Utility MACT) applies to Electric Generating Units (EGU s) 3 PM compliance options PM CPMS (not typically used in MATS rule) PM CEMS (certified using PS-11) Quarterly reference method tests (MATS Method 5 or metals method) PM limits for bituminous coal fired EGU s (30 day rolling averages) Existing Source: 0.03 lbs/mmbtu (~24 mg/am^3) New Source: 0.007 lbs/mhr (~4 mg/am^3) 5

ICI Boiler MACT Industrial/Commercial/Institutional Boiler MACT rule has a long complicated history Typical affected sources are pulp and paper mills, other manufacturers (grain processors, autos, etc.), steam heating boilers for large commercial & institutional building complexes PM CEMS/CPMS needed for coal & oil fired boilers (biomass excluded) with heat rate >= 250 mmbtu/hr, which is about 75 MW. PM limits for existing boilers vary by subcategory (biomass, oil, pulverized coal, etc.) but are similar to EGU MATS rule limits. Bag houses (fabric filters) need Bag Leak Detector Opacity limit of 10% for sources >10 mmbtu/hr and <250 mmbtu/hr 6

PS-11 & Procedure 2 Approach Note that due to Feb 2014 change to PS-11, Calibration Drift is now assessed versus Range (previously was versus Upscale Reference). PS-11 Correlation Test 7 day drift test (self check error <=2% of range) Initial calibration On going QA Zero and Span Quarterly ACA 1 year RRA: (Relative Response Audit) 3 Run Calibration check RRA 3 years RCA: (Relative Correlation Audit) 12 Run Calibration check RCA Time PS-11 Procedure 2 7

PS-11 Correlation Test Minimum of 15 runs in 3 bins (0 to 50%, 25% to 75%, 50% to 100% of maximum RM value of PM). Bag house sources w/o bypass have difficulty elevating emissions Ash from ESP or bag house can be injected downstream (not recommended for wet sources) PS-11 does allow use of zero point data from the PM CEMS in lieu of the 3 bins Acceptance criteria Correlation Coefficient <= 0.85 Confidence Coefficient <= 10% of emission limit Tolerance Interval <= 25% of emission limit X = PM Y = RM, CEMS, % mg/m^3 10 1 9.2 1.2 24.3 2 25.2 2.21 Model Types Linear 2 nd Order Polynomial Logarithmic Exponential Power 8

EGU Wet FGD Plant Abatement Processes PM CEM s have been installed on many US EGU wet stacks after various abatement processes Wet FGD and ESP with occasional bag house in place of ESP Some with SNCR, some with SCR, some with no de-nox Some with Ca(OH) 2 sorbent injection SNCR with Urea or NH3 Injection SCR with NH3 Injection Sorbent Injection for SO3 Control ESP (Electrostatic Precipitator) Wet FGD 9

Value of PM CEMS Abatement plant optimization Annual vs Quarterly Testing Continuous feedback on plant operation Hydrated Lime Injection FGD Inlet Opacity Wet Stack PM CEM Sorbent injection OFF Sorbent injection ON 10 1 0

STACK 181WS PM CEM / CPMS Measurement Concept 1. Extract wet flue gas at appropriate velocity (can sample at fixed or variable velocity) 2. Change liquid content into gas phase 3. Measure dust concentration with light scatter technique 4. Return sample back to stack Sample Flow Venturi Purge Air Heater 11

STACK 181WS Improvements Purged Sample Chamber (PSC) Improves maintenance interval, reduces cost of ownership by Reducing sample chamber dead spaces where contamination can accumulate Heating purge air preventing formation of condensation on optics Currently installed at several US Electrical Utility stacks with excellent results 12

181 ProScatter Forward Scatter Technology Conical mirror improves light collection by gathering full cone of scattered light. Narrow forward scatter angle minimizes effect of changing particle size. While the calibration is still sensitive to changes in particle size, ProScatter has reduced sensitivity compared to designs using angles further from angle of incidence. Span check is provided by introducing a scatter body in light path. Particles create scattering in Interaction volume 13 13

PCME Wet Stack Particulate Monitor STACK 181WS PS-11 Correlation Tests Upscale particulate achieved by detuning plant (removing precipitator banks, turning off FGD pumps) Reference was MATS Method 5 (160º C filter temperature) 14

1 Variability in PS-11 Correlation Test Slopes at Fifteen STACK 181WS s 2 3 PS-11 Correlation Curve Coefficients 4 5 6 7 b0 1.751 1.945 1.416 1.211 1.758 3.11-0.146 1.528 3.30 4.29 9.59 13.30 5.43 6.95 6.41 b1 0.910 0.24 0.37 0.383 0.292 0.34 0.424 0.399 0.315 0.32 0.32 0.30 0.38 0.84 0.81 b2 0 0 0 0 0 0 0 0 0 0 0 0 0 0 0 Plant configurations All had Wet FGD & Precipitator; many other differences Slopes clustered in two groups 0.24 to 0.42 0.81 to 0.91 Why the difference? May be due to particle size dissimilarity from various but constant plant configurations 8 9 10 11 12 15 13 14 15 15

PCME s background in PM monitoring Specialist supplier of PM monitors (30,000 to industrial processes across 6 continents) Core technologies Light scatter Electrodynamic Scintillation Recently expanded US based service and support capability 16