Heat Load Calculation for the Design of Environmental Control System of a Light Transport Aircraft

Similar documents
Environmental Control System Testing and Performance Evaluation of a Transport Aircraft

COP-OPTIMISED PRESSURE CONTROL FOR A CENTRALISED CO 2 COOLING SYSTEM IN AIRCRAFT APPLICATIONS

RESEARCH ON INTEGRATION OF VAPOR CYCLE/LIQUID-COOLED REFRIGERATION SYSTEM FOR HELICOPTERS

Eng Thermodynamics I: Sample Final Exam Questions 1

Problems in chapter 9 CB Thermodynamics


Eng Thermodynamics I - Examples 1

Solar Flat Plate Thermal Collector

Eng Thermodynamics I - Examples 1

MCG THERMODYNAMICS II. 22 April 2008 Page 1 of 7 Prof. W. Hallett

CHAPTER 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

COMPARATIVE ANALYSES OF TWO IMPROVED CO 2 COMBINED COOLING, HEATING, AND POWER SYSTEMS DRIVEN BY SOLAR ENERGY

Calculation document. Introduction

LECTURE-14. Air Refrigeration Cycles. Coefficient of Performance of a Refrigerator:

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

- 2 - SME Q1. (a) Briefly explain how the following methods used in a gas-turbine power plant increase the thermal efficiency:

Enhancement of CO2 Refrigeration Cycle Using an Ejector: 1D Analysis

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Thermally operated mobile air-conditioning system

Thermodynamics: An Engineering Approach, 6 th Edition Yunus A. Cengel, Michael A. Boles McGraw-Hill, 2008

Second Law of Thermodynamics

Internal Environments for Aircraft

CH 7: GAS-TURBINE ENGINES Prepared by Dr. Assim Al-Daraje BRAYTON CYCLE: THE IDEAL CYCLE FOR GAS-TURBINE ENGINES

Chapter 5 MASS AND ENERGY ANALYSIS OF CONTROL VOLUMES

Type CTM 6 High Pressure (HP) and Low Pressure (LP)

a. The power required to drive the compressor; b. The inlet and output pipe cross-sectional area. [Ans: kw, m 2 ] [3.34, R. K.

Applied Thermodynamics - II

CERTIFICATES OF COMPETENCY IN THE MERCHANT NAVY MARINE ENGINEER OFFICER

ERT 318/4 UNIT OPERATIONS SEMESTER 1 (2013/2014)

Practice Final Exam (A) Six problems. (Open-book, HW solutions, and notes) (Plus /minus 10 % error acceptable for all numerical answers)

Investigation on effects of piping on heating performance of multi-split variable refrigerant flow system

R13 SET - 1 '' ''' '' ' '''' Code No: RT31035

Code No: R31034 R10 Set No: 1

STEAM TURBINE-GENERATOR & AUXILLIARY SYSTEMS Presentation by: RANA NASIR ALI General Manager, Power Plants Projects, at PITCO November 02, 2017

Pinch Analysis for Power Plant: A Novel Approach for Increase in Efficiency

OPTIMIZATION OF PARAMETERS FOR HEAT RECOVERY STEAM GENERATOR (HRSG) IN COMBINED CYCLE PLANTS

Chapters 5, 6, and 7. Use T 0 = 20 C and p 0 = 100 kpa and constant specific heats unless otherwise noted. Note also that 1 bar = 100 kpa.

INSTITUTE OF AERONAUTICAL ENGINEERING (Autonomous) Dundigal, Hyderabad

HEATMAX. Mechanical Installation and Commissioning Instructions HEATMAX

Department of Mechanical Engineering. MSc/PGDip/PGCert in Energy Systems and the Environment. Specialist Modules

A Method for On-Going Commissioning of VRV Package Systems Using a. Simulation Model

A piston expander for exhaust heat recovery on heavy commercial vehicles

YKN2open A R C 032 A B

Heat Rejection using Cooling Towers

R13. (12M) efficiency.

Enhancement in Efficiency of Cooling System of Vehicle by optimizing an air Flow and Avoiding Hot Air Recirculation

UNIVERSITY OF TORONTO FACULTY OF APPLIED SCIENCE AND ENGINEERING FINAL EXAMINATION, DECEMBER 2008 MIE 411H1 F - THERMAL ENERGY CONVERSION

SorTech package solution description

Chapter 9: Vapor Power Systems

DESIGN OF VAPOUR ABSORPTION REFRIGERATION SYSTEM OF 1.5TR CAPACITY BY WASTE HEAT RECOVERY PROCESS

> HGW WATER - WATER AND BRINE - WATER HEAT PUMPS FOR INDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Chapter Two { TC "Chapter Two " \l 1 } Detailed System Description

The Benefit of Variable-Speed Turbine Operation for Low Temperature Thermal Energy Power Recovery

Environmental Control Systems and the Cabin Environment

Review Questions for the FE Examination

The energy benefits of View Dynamic Glass

Written Exam 02 March Problems - Time: 2 hours PLEASE NOTICE

Boiler Efficiency Testing. To understand the operation of a fire tube boiler To determine the operating efficiency of the boiler

Module 05 Lecture 35 : Low temperature process design Key words: Refrigeration system

High efficient heat reclaim with CO2

INCENTIVE ESTIMATOR HVAC USER GUIDE CONTENTS FLORIDA CUSTOM INCENTIVE PROGRAM

Heat Transfer Analysis Collector

AP1000 European 15. Accident Analysis Design Control Document

Utilization of THERMOPTIM Optimization Method

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

Second Law Analysis of a Carbon Dioxide Transcritical Power System in Low-grade Heat Source Recovery

7 th NATIONAL CERTIFICATION EXAMINATION Nov FOR ENERGY MANAGERS & ENERGY AUDITORS

The Potential and Challenges of Solar Boosted Heat Pumps for Domestic Hot Water Heating

MECHANICAL ENGINEERING THERMAL AND FLUID SYSTEMS STUDY PROBLEMS

Modeling Techniques for Increased Accuracy

DYNAMIC SIMULATION OF A PROTON EXCHANGE MEMBRANE FUEL CELL SYSTEM FOR AUTOMOTIVE APPLICATIONS

Appendix B. Glossary of Steam Turbine Terms

IECC 2015 with Hawaii Amendments COMMERCIAL DESIGN CHECKLIST

Draft proposals for Test methods for close-coupled solar water heating systems - Reliability and safety

Study of the Electric Vehicle Heat Pump Air-conditioning System

Code No: RR Set No. 1

HIGH EFFICIENCY SHOWERS WASTE WATER HEAT RECOVERY UNIT. Saved power 80kW. Showers waste water 9 C Power consumption 3,1kW. Showers waste water 31 C

Design, modelling, performance optimization and experimentation of a reversible HP/ORC prototype.

innovative accumulator tanks

MEASURING MICROPARTICLE IMPACT CHARACTERISTICS UNDER REALISTIC GAS TURBINE CONDITIONS. A.G. Friedman, W.F. Ng Virginia Tech

2. TECHNICAL DESCRIPTION OF THE PROJECT

Performance Mapping for Variable Ductless Heat Pump Systems in Heating, Cooling and Defrost Operation

GHP Data Collection and Monitoring System at the SRRL

Energy Optimization Using Pinch Analysis

THERMAL AND ELECTRICAL PERFORMANCES OF A NEW KIND AIR COOLED PHOTOVOLTAIC THERMAL SYSTEM FOR BUILDING APPLICATION

Design Features of Combined Cycle Systems

Farm Energy IQ. Farms Today Securing Our Energy Future. Farm Energy Efficiency Principles Tom Manning, New Jersey Agricultural Experiment Station

Guidance page for practical work 1: modeling of a thermodynamic solar plant

Combined Heat and Power

AP1000 The PWR Revisited

2. The requirements of Sections 502, 503, 504 and 505. In addition, commercial buildings shall comply with either Section 506.2, or

CHAPTER 2 STUDY OF 210 MW BOILER SYSTEM 2.1 DESCRIPTION OF 210 MW BOILER

Performance Analysis and Diagnostics of a Small Gas Turbine

Chapter Six{ TC "Chapter Six" \l 1 } System Simulation

SIMPACK - MODEL DEVELOPMENT PACKAGE FOR POWER PLANTS

THERMAL POWER PLANT SIMULATOR TPP 200 LABORATORY EXERCISE TUTORIAL N4: INTRODUCTION TO THE HEAT PRODUCTION SYSTEM

Healthy Buildings 2017 Europe July 2-5, 2017, Lublin, Poland

In this lecture... Solve problems related to First law of thermodynamics for closed and open systems Heat engines Refrigerators and heat pumps

DIN EN , DIN EN , DIN EN , DIN EN

Sample Conditioning for the water-steam cycle

Transcription:

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 249 Heat Load Calculation for the Design of Environmental Control System of a Light Transport Aircraft Rahul Mohan.P1, Joyal Varghese1, M L Shankar2, Vinay C.A2 Abstract -- Environmental Control System (ECS) is a generic term used in aircraft industry for maintaining the required air temperature and pressure inside passenger and crew compartment. The real challenge for an ECS is to operate and supply adequate cooling over a wide range of ground and flight conditions in a most reliable and efficient manner. The most important aspect of ECS is to know the cabin heat loads during air cooling or air heating phases. A precise calculation of aircraft heat load would be a long process requiring detailed knowledge of the aircraft structure and of the quantities involved in the mechanism of heat pick up and interchange in the cabin. This paper describes a method that may be applied in calculating the heat load for any aircraft and calculations are shown for a typical light transport aircraft under the conditions that, the cabin altitude is maintained within 0 ft to 8000 ft (2438.4m) for the aircraft altitude of 0 ft to 25000ft (7620m). The system shall be capable of maintaining temperatures within 59 F to 75 F (15 C to 30 C). Index Terms - Aircraft, Cabin Altitude, Cold air unit, Cooling Capacity, ECS, Heat Load, Heat exchanger 1 INTRODUCTION The most important aspect of ECS is to know the cabin heat loads during air cooling or air heating phases. A precise calculation of aircraft heat load would be a long process requiring detailed knowledge of the aircraft structure and of the quantities involved in the mechanism of heat pick up and interchange in the cabin. However, it is possible to make a sufficiently accurate estimate using mean quantities for calculating the heat transfer process providing we know the essential details of the cabin structure such as the transparency areas and the external wall areas and whether or not the aircraft is to be insulated. NOMENCLATURE TBW Tun HR hi G M Cp b Trc Tp QT Qc r tc tamb - Non-Insulated Bulkhead Wall Temperature (ok) - Non-Insulated Projection Temperature (ok) - Equivalent Radiation Coefficient (W/m2K) - Internal Heat Transfer Coefficient (W/m2K) - Transmissivity of the material - Solar Radiation Intensity (w/m2) -Mach number -Specific Heat of Air (KJ/Kg-K) -Mass flow rate from ECS pack (Kg/s) - Re-circulated air temperature from cabin (ok) --Air temperature from ECS pack (ok) - Total Heat Load (KW) - Cooling Capacity (KW) - Recovery Factor - Cabin Temperature (oc) - Ambient Temperature (oc) T s -Skin temperature ( o K) T amb -Ambient temperature ( o K) γ -Isentropic factor of air Q - Heat Transferred (W) U - Overall Heat Transfer Coefficient (W/m 2 K) Ac1 - Insulated External Wall Area ( m 2 ) Ac2 - Un-Insulated External Wall Area ( m 2 ) AB1 - Insulated Bulkhead Area ( m 2 ) AB2 - Un-Insulated Bulkhead Area ( m 2 ) A5 - Non-Insulated Projected Area ( m 2 ) A6 - Floor Area ( m 2 ) A10 - Passenger Compartment Window Projected Area( m2) A11 - Windscreen Window Projected Area ( m2) A12 - Flight Deck Side Window Projected Area ( m2) Acw - Passenger Compartment Window Total Area ( m2) Aww - Windscreen Total Area ( m2) Afd - Flight Deck Side Window Total Area ( m2) Ts - Skin Temperature (ok) Tc - Cabin Temperature (ok) TB - Adjacent Bay Temperature (ok) Tf - Under Floor Temperature (ok) Fig 1 Configuration of a Typical ECS For example, to predict accurately the heat pick up due to convection one should know the internal airflow over the

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 250 various surfaces. It is not possible to predict the flow through the high-pressure water separation system distribution particularly in the case of a small cockpit condenser / water extractor (item 11), the air enters the where the velocity may vary widely throughout. Hence turbine section of the Cold Air Unit (CAU) where it related to internal heat transfer co-efficient to the air mass expands and gets cooled. The power produced by the flow per unit volume of the cabin. ECS system has to be turbine in expanding the air is used to drive the designed by considering the critical heat loads in order to ensure an acceptable temperature level and sufficient air compressor. The expansion in the turbine causes a supply in the cabin. Thus the heat load of steady-state heat substantial temperature reduction, resulting in sub-zero balance is the necessary input for designing an air turbine discharge temperature. When operating on the conditioning system. The typical configuration of a classic ground and at low Mach numbers coolant air for the ECS is shown in Fig.1. primary/ secondary Dual Heat Exchanger (item 10) is 2 SYSTEM DESCRIPTION induced by a Ground Cooling (GC) fan (item 18). The GC fan is ON can be used on ground and is switched OFF In the Light Transport Aircraft (LTA), the air conditioning when the MLG is retracted after getting airborne. During system operates using engines bleed air and supplies flight and at high Mach numbers, ram air is used. A Non controlled conditioned air to the passenger and the crew Return valve (item 28) prevents reverse flow of the cooling compartments. Refrigeration is produced by a single bootstrap air cycle system. The schematic arrangement of air. The air from the outlet of the CAU turbine passes the air conditioning system is shown in Fig.2. through the coolant side of the condenser to be mixed with The temperature control functions are accomplished re-circulated cabin air. The Non Return valve (item 41) automatically by an electronic controller in conjunction prevents flow to the Ground Connector (item 42) and the with an electro-pneumatic Temperature Control Valve. Non Return valve (item 40) prevents flow to the emergency Scheduled maintenance has been minimized by the use of supply line. If air is supplied from either the ground air bearings in the Cold Air Unit (CAU) and high pressure connector or the emergency supply, the Non Return valve water separation. Re-circulated cabin air is mixed with subzero air conditioning pack outlet air to achieve the required (item 16) will prevent reverse flow to the air conditioning cabin conditioning airflow with minimum engine bleed pack. The water drained from the condenser/water airflow, in order to maintain cabin and crew compartment extractor (item 11) is sprayed into the Dual Heat Exchanger temperature in the range of 15 C to 30 C up to altitude of cooling air inlet through a water spray nozzle (item 17). 25,000 ft. This reduces the temperature of ram air by evaporation of 2.1 System Operation the water. Conditioned air from the air conditioning pack mixes into re-circulated cabin air in the pressurized area of With reference to Fig.2 engine bleed air enters the system the aircraft. This air is delivered to both the crew and from either the LP bleed port via a Non-return valve (item passenger compartments. The recirculation air does not 1a & 1b) or the HP bleed port via a Pressure Reducing and penetrate the pressure bulkhead. Re-circulated cabin air is Shut-Off valve (item 2a & 2b) depending on the bleed added to pack-conditioned air via a filter (item 25) by an temperatures and pressures. The bleed air then, flows electrically driven fan (item 24) allows hot air to bypass the through a Pressure Regulating and Shut-Off valve (item 3a cooling pack to raise the pack outlet temperature when full & 3b) and into the system. The bleed air from the two cooling is not required. This hot air is mixed with packconditioned engines is then combined to pass through the Shut-Off air at the turbine discharge upstream of the valve (item 6) and the flow limiting venturi (item 7) before condenser. A turbine inlet low limit control valve (item 12) entering the primary section of the Dual Heat Exchanger is used to prevent excessively low turbine inlet (item 10). The bleed air is cooled by passing through the temperatures on cold days. This prevents icing on the Primary section of the Dual Heat Exchanger and then it condenser. The condenser also incorporates heated header enters the compressor section of the Cold Air Unit (item 9) bars to reduce formation of ice. Hot air supply is taken from where it is compressed. The heat of the compression is the compressor outlet and returned to the air conditioning removed in the Dual Heat Exchanger (item 10) where the pack at the primary section outlet of the Dual Heat temperature is reduced to near the ambient air (used for Exchanger. cooling in heat exchanger) temperature. After passing

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 251 valve towards the closed position. This control action limits the maximum supply air temperature to 80±5 C. 2.2 Backup Emergency Supply In an emergency to maintain the pressurization, in the unlikely event of pack failure, is provided. The air supply 2.1 Backup Overheat Protection An overheat protection backup is provided by the Duct Temperature Limiter (item 23) which prevents supply of hot air above 65 C either due to malfunction of the automatic system or inappropriate manual mode system operation. When the temperature of supply air exceeds 65 C the Duct Temperature Limiter opens in response to further temperature increases and actuates the butterfly from both engines enters the Pre-cooler (item 33) where its temperature is reduced by ram air-cooling. A pneumatic sensor (item 35) fitted around the Pre-cooler enables bypassing engine bleed air on cold days by controlling the temperature control. The air is then supplied via a pressure Fig 2 ECS schematic for this system is taken from the alternative HP bleed port. The emergency air supply is controlled by Shut-Off and Non-Return valves (items 31 & 32) fitted for each engine. The Shut-Off valve is opened by an electrical signal. The Non Return valve is to ensure that air cannot be cross-bled from one engine to the other engine. The air supply after combination reducing and shut off valve (item 38) and venture (item 39), which control total flow of emergency air to cabin. On ground, ram air to the pre cooler (item 33) is initiated by jet pump SOV (item 32) and jet pump (item 45).

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 252 2.3 System Protection The over-temperature switch (item 30) is required to regulate the supply of hot temperature air from the engine. In the event of failure of the over-temperature switch (item 30), two additional over-temperature switches (item 4) are fitted downstream of the Pressure Regulating and Shut-Off Valve (item 3). These additional over temperature switches will signal both engine Pressure Regulating and Shut-Off Valves (item 3) and the Pack Inlet Shut-Off Valve (item 6) to close and illuminate the warning light ECS (item 27). In the case of failure of Pressure Regulating and Shut-Off Valves (item 3), the pack inlet Shut-Off Valve (item 6) will get the signal to close thereby protecting the air conditioning pack from supply of air at overpressure. At the same time the warning light (item 27) will also be illuminated. U 3 A B1 (T B T c ) (3) Convection from Non-Insulated Bulkhead Wall (Q4) (W) U 4 A B2 (T B T c ) (4) Convection from Non-Insulated Projections (Q5) (W) U 5 A 5 (T s T c )η f (5) Convection from Floor (Q6) (W) U 6 A 6 (T f T c ) (6) Radiated Heat from Non-Insulated External Wall (Q7) (W) H R1 A c2 (T s T c ) (7) Radiated Heat from Non-Insulated Bulkhead Wall (Q8) (W) H R2 A B2 (T BW T c ) (8) 3 AIRCRAFT HEAT LOAD Aircraft heat load can be regarded as heat coming from mainly four aspects, the fuselage wall, the solar radiation, the aircraft occupants and the electronic-electrical equipment [1]. It is easy to describe these sources but difficult to finish a complete and precise calculation because there are so many factors that should be taken into account at the same time. Further, flight altitude and speed also affect the calculation results. Following sections describes the typical method used to estimate the aircraft heating and cooling load in terms of the Light Transport Aircraft (LTA) structural parameters and cabin layout. 3.1 Estimation of Cabin Heat Load The heating and cooling loads which have to be considered in sizing the environmental control system are: Convection from External Insulated Wall (Q1) (W) U 1 A c1 (T s T c ) (1) γ T s = T amb 1 + r 1 M 2 2 r- Recovery factor, γ Isentropic factor T s = T amb (1 + 0.18M 2 ) r = 0.9, γ = 1.4 is assumed Convection from Non-insulated Wall (Q2) (W) U 2 A c2 (T s T c ) (2) Convection from Insulated Bulkhead Walls (Q3) (W) TBW = T c + U 4 h i (T B T c ) Radiated Heat from Non-Insulated Projections (Q9) (W) H R3 A 5 (T un T c ) (9) T un = T c + η f (T s T c ) Solar Radiation through Passenger Compartment Windows (Q10) (W) 0.5A 10 ƮG Solar Radiation through Windscreen (Q11) (W) (10) A 11 ƮG (11) Solar Radiation through Flight Deck Side Windows (Q12) (W) A 12 ƮG (12) Convection through Passenger Compartment Windows (Q13) (W) U 13 A cw (T s T c ) (13) Convection through Windscreen (Q14) (W) U 14 A ww (T s T c ) (14) Convection through Flight Deck Side Windows (Q15) (W) U 15 A fd (T s T c ) (15) Occupants Metabolic Heat Release (Q16) (W) Total metabolic heat release is assumed as 116 W per person. [1] Electrical and Avionic Heat Load (Q17) (W)

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 253 500W is assumed as electrical and avionic heat release. TABLE 2 Total Heat Load (QT) EQUIVALENT RADIATION COEFFICIENT FOR 17 Q i i=1 (16) LAYERS NON INSULATED WALL EQUIVALENT RADIATION COEFFICIENT (W/M 2 K) 3.2 Sample Calculation of Heat Load Sample calculation is carried out for typical flight cases as follow as; Case: Hot Day 25000 ft Cruise NON-INSULATED EXTERNAL WALL NON-INSULATED BULKHEAD WALL NON-INSULATED PROJECTIONS 3.58 4.43 4.09 Cabin Temperature tc =24 o C, Tc= 297.15 o K (assumed) Mach Number (M) = 0.34 tamb = -9.5 o C, Tamb = 263.65 K T s = 1 + 0.18M 2. = 268.9 o K TABLE 1 THERMAL CONDUCTANCE OF EACH LAYER LAYERS THERMAL CONDUCTANCE (UA) (W/K) INSULATED SKIN 27.96 UN INSULATED SKIN 68.99 INSULATED BULKHEAD 3.53 UN INSULATED BULKHEAD 0.515 FLOOR 32.52 PASSENGER CABIN WINDOWS 5.34 WINDSCREEN 9.17 TABLE 3 HEAT LOAD SUMMARY HEAT LOAD KW Q1-0.78 Q2-1.93 Q3 0.007 Q4 0.001 Q5-0.48 Q6-0.455 Q7-0.812 Q8 0.000532 Q9-0.230 Q10 0.268 Q11 0.595 Q12 0.207 Q13-0.149 Q14-0.257 FLIGHT DECK SIDE WINDOWS 9.04 Q15-0.253 Q16 1.856 Q17 0.5

International Journal of Scientific & Engineering Research, Volume 7, Issue 5, May-2016 254 5 RESULTS The Table 4 below shows the heat load and cooling capacity of the pack under critical flight cases. TABLE 4 SUMMARY OF CABIN HEAT LOAD/COOLING CAPACITY FOR CRITICAL FLIGHT CONDITIONS Fig 3 Solar Radiation Intensity through Altitude [3] Total Heat Load (QT) 17 Q T = Q i = Q 1 + Q 2 + Q 3 + Q 4 + Q 5 + Q 6 + Q 7 + Q 8 + Q 9 + Q 10 + Q 11 + Q 12 + Q 13 + Q 14 + Q 15 + Q 16 + Q 17 i=1 = 0.78 1.93 + 0.007 + 0.001 0.48 0.455 0.812 + 0.000532 0.23 + 0.268 + 0.595 + 0.207 0.149 0.257 0.253 + 1.856 + 0.5 = 1.91 KW 4 COOLING CAPACITY Cooling capacity gives an idea of the ability of the pack to take out the available heat load. Cooling capacity of ECS pack can be found from the conservation of energy equation. Q c = ṁ b C p (T rc T p ) (18) The cooling capacity of free water is not considered 4.1 Sample Calculation Case: Hot Day 25000 ft Cruise ṁb = 0.047 Kg/s Cp = 1.005 KJ/Kg o K SI NO PHASE M ALTI- TUDE (ft) t amb ( 0 C) QT (KW) Qc (KW) 1 CLIMB 0.44 10000 20.19 4.6 4.66 2 CLIMB 0.47 20000 0.38 0.974 1.07 3 CLIMB 0.47 25000-9.5-0.988-0.992 4 CRUISE 0.3 10000 20.19 3.27 3.38 5 CRUISE 0.43 10000 20.19 4.72 4.75 6 CRUISE 0.3 20000 0.38-0.272-0.277 7 CRUISE 0.46 20000 0.38 0.885 1 8 CRUISE 0.34 25000-9.5-1.91-2.07 9 CRUISE 0.44 25000-9.5-1.21-1.23 10 DESCENT 0.2 0 40 4.48 5.089 11 DESCENT 0.24 10000 20.19 2.51 2.64 12 DESCENT 0.3 20000 0.38-0.272-0.422 13 DESCENT 0.33 25000-9.5-1.98-1.98 6 CONCLUSION A precise calculation of aircraft heat load would be a long process requiring detailed knowledge of the aircraft structure and of the quantities involved in the mechanism of heat pick up and interchange in the cabin. This paper has given the typical approach followed in estimating the heat loads precisely for the transport aircraft. Q c = ṁ b C p (T rc T p ) Trc = 296.15 o K Tp = 340.15 o K Q c = 0.047 1.005 (296.15 340.15) = -2.07 KW The re-circulated temperature will be slightly above or below compared to the cabin temperature and is depended on the thermal load, work done by re-circulated fan, duct conductions etc, and for calculation it is assumed on the basis of available ECS test data from similar class of aircrafts. ACKNOWLEDGMENT The authors wish to thank all partners and associated partners for their contribution to the program and for their permission to publish this paper REFERENCES [1] Paolo, A. (2009), Numerical Models for Aircraft Systems lecture notes, Chapter 6 Environmental Control System, Politecnico Di Milano. [2] Shou, R. and He, H. (2004), Flight Vehicle Environmental Control, Press of Beijing University of Aeronautics and Astronautics. [3] SAE Aerospace, Applied Thermodynamics Manual, (2004), Air Conditioning Load Analysis, Society of Automotive Engineers, USA.