Biacore The high performance research system. Work with high sensitivity

Similar documents
Basic Biacore Course. Introduction to SPR technology. Biacore Training

Label-free interaction analysis in realtime using surface plasmon resonance

Biacore X100. GE Healthcare Life Sciences. Biacore X100 Plus Package. Biacore X100 delivers:

GE Biacore T Check that the waste bottle is empty.

Confidently analyze the widest range of targets with unmatched flexibility and sensitivity.

BIA Experimental Designs

The World Leader in SPR Technology. Jimmy Page, PhD, Biacore, Inc.

SURFACE PLASMON RESONANCE-BASED SYSTEMS

Precise. Flexible. Robust. Affordable.

Performance of a fast Surface Plasmon Resonance based MAb quantification method

Reflected light a b. prism. flow chamber. flow chamber

Biacore 8K. One solution for small molecule and biotherapeutic screening/characterization. GE Healthcare. Label-free interaction analysis

Characterization of Small Molecule to Protein Binding

Surface Plasmon Resonance Systems

Biomarker Discovery using Surface Plasmon Resonance Imaging

GE Healthcare. Biacore X100. Getting Started

Explore the future. Automotive Test Systems Process & Environmental Medical Semiconductor Scientific

Enhance Your Protein Interaction Research with A New Level of Bench-Top Productivity

Validation of a concentration assay using Biacore C

Protein Interaction Analysis

Regeneration Scouting Kit

Label-free interaction analysis Biacore 8K and Biacore 8K+

University of Colorado Denver, Biophysics Core Facility August 2008

GE Healthcare Life Sciences. A year of interaction with Biacore X100

Biacore. Sensor Surface Handbook

Surface Plasmon Resonance Analyzer

Biacore System description. GE Healthcare. Biacore label-free interaction analysis. Optional software packages

GE Healthcare Life Sciences. Biacore systems. Confidence that comes with the right interactions

protein interaction analysis

Reducing Non-Specific Binding in Surface Plasmon Resonance Experiments

Characterization of Aptamer Binding using SensíQ SPR Platforms

Instruction AB

The use of surface plasmon resonance to guide the choice of nucleic acid oligomers for co-crystallisation with proteins

AC Immune SA, Lausanne, Switzerland *For correspondence:

Label-Enhanced SPR Improves the Detectability of Label-Free Surface Plasmon Resonance Analysis 100x

Protein-peptide Interaction by Surface Plasmon Resonance Eiji Ishii, Yoko Eguchi and Ryutaro Utsumi *

Maximizing Sample Recovery on the ACCQPrep HP125

OpenPlex. Multiplex Label-Free Interaction Analysis. Open Research Platform

Ligand immobilization using thiol-disulphide exchange

GE Healthcare Life Sciences. Biacore Assay Handbook

MagSi Beads. Magnetic Silica Beads for Life Science and Biotechnology study

Accelerate mab Characterization Using Automated Sample Prep

Developing a natural partnership for rapid, sensitive identification of binding partners

Phage Antibody Selection With Reichert SPR System

Molecular Interactions Research

Please note that in order to obtain useful results, the input values should be in the correct units (as indicated per input cell).

Solvent Correction versus In-line Reference Measurement

ProteOn XPR36 Quantikinetics: Antibody Concentration and Detailed Kinetic Analysis in a Single Experimental Cycle

Characterization of drug-plasma protein interactions using surface plasmon resonance

Application of Biacore Technology

PD-1 [Biotinylated] : PD-L1 Inhibitor Screening ELISA Assay Pair

Fast, precise, and accurate

Ordering Information. ProteOn XPR36 System. Protein Interaction Analysis

LabChip GXII: Antibody Analysis

quantification of an oligonucleotide

SensoLyte 520 Factor Xa Assay Kit *Fluorimetric*

Dialysis. Devices and Tubings. ReadyLyzer. Xpress Dialyzer. Xpress Equilibrium Dialyzer. MEMBRA-CEL Dialysis Membranes. SERVAPOR Dialysis Membranes

BIAffinity Application Note

Human procollagen type III (HPCⅢ) ELISA Kit

PRODUCT DATA SHEET. Carboxylated Gold Nanoparticles. Description. Features. Storage. Applications. Handling. Characteristics

Advantages of Dialysis. Applications. Disadvantages of Dialysis. Tips for Application. Definition and used Terms. Scienova s Xpress MicroDialyzer

Qualifying SPR immunogenicity assays Dr. Christian Kühne

protein interaction analysis bulletin 6299

Target-based drug discovery and lowbinding affinities using Biacore 8K

Size Exclusion BioHPLC columns Ion Exchange BioHPLC columns

R R Innovation Way P/N SECKIT-7830 Newark, DE 19711, USA Tel: Fax: Website: Published in November 2013

20.320, notes for 9/13

Discovery of an entropically-driven small molecule streptavidin binder from nucleic acid-encoded libraries

Supplementary Figure 1. Binding capacity of the nanoparticles. Protein A-coated magnetic nanoparticles were mixed with FITC-antibody (antibody

Introduction to Assay Development

EPIGENTEK. EpiQuik In Vivo Protein Sumoylation Assay Ultra Kit. Base Catalog # P-8003 PLEASE READ THIS ENTIRE USER GUIDE BEFORE USE

Human Sortilin (Soluble) ELISA Kit

TNF (Pig) ELISA Kit. Catalog Number KA assays Version: 05. Intended for research use only.

Improving biosensor analysis

protein interaction analysis tech note 5367

AssayMAP. Mitu Chaudhary Product Marketing Manager Bay area product specialist Robert (Bob) Boice

Sensitive protein:ligand biochemical assays using Corning Epic label-free technology on the EnSpire Multimode Plate Reader

Supplementary information

SpectraMax Paradigm Microplate Reader

Routine Characterization of DNA Aptamer Affinity to Recombinant Protein Targets

Downstream Processing (DSP): Microscale Automation of Biopharmaceutical Processes. Michel Eppink, Synthon BV, Nijmegen, The Netherlands

The NEW. SR7500DC System. The Next Generation of Surface Plasmon Resonance

Biosensing Probe for Quality Control Monitoring of the Structural Integrity of Therapeutic Antibodies

Mimetic Blue Affinity Adsorbents Mimetic Blue 1 P6XL, Mimetic Blue SA P6XL Mimetic Blue SA HL P6XL, Mimetic Blue ELISA Kit

PRINCIPLE OF THE ASSAY

MST Starting Guide Monolith NT.115

Phenyl Membrane Adsorber for Bioprocessing

Thermo Scientific Mass Spectrometric Immunoassay (MSIA) Pipette Tips. Next generation immunoaffinity. Robust quantitative platform

HUMAN TRANSFORMING GROWTH FACTOR BETA 1 (TGF- 2) ELISA KIT

Rat / Mouse Amylin EIA Kit

Nano-mechanics of Biostructures. --from energy to force in biochemistry--

LabChip 90 System with DataViewer Software

ImmuLux Human IL-6 Fluorescent ELISA Kit

Capillary Electrophoresis of Proteins

Human ICAM-2 / CD102 ELISA Pair Set

Data Sheet. PD-1[Biotinylated]:PD-L2 Inhibitor Screening Assay Kit Catalog # Size: 96 reactions

Human IGFBP3 ELISA Pair Set

Simplifying ImmunoAffinity Capture Workflow

Understanding the Effects of Common Mobile Phase Additives on the Performance of Size Exclusion Chromatography

Data Sheet PARP1 Chemiluminescent Assay Kit Catalog # 80551

Transcription:

Biacore 3000 The high performance research system Work with high sensitivity direct detection of small molecules at < 1 nm concentration increased resolution for kinetic analysis measurement of weak affinities Recover bound analyte in high concentration Deliver recovered analyte to vial or direct to MALDI target Shorten analysis times Minimize sample consumption Study binding in non-aqueous and aqueous samples Use Biacore Wizards to simplify and accelerate analysis Develop specialized applications efficiently Perform the most advanced kinetic evaluation Introduction Biacore 3000 is the highest performance research system available for label free studies of biomolecular binding. Samples ranging from small molecules to crude extracts, lipid vesicles, viruses, bacteria and eucaryotic cells can be studied. Biacore 3000 answers questions about the speed, strength and specificity of binding and determines the active concentrations of components. Technical innovations meet the highest demands for sensitivity, efficiency and flexibility. With new wizard driven and automated recovery functions including the novel Surface Prep unit for increased capacity recovery, Biacore 3000 is an ideal tool for functional proteomics. Increased integration with mass spectrometry characterization is provided by the enhanced recovery and ability to directly deliver sample to a MALDI target as well as delivery of digestion enzymes and MALDI matrix, all within the autosampler of the system. The knowledge and experience of Biacore has been incorporated into Wizards which guide the user without effort through preparation, experimentation and evaluation. Biacore Wizards provide a trend analysis and preliminary results at the end of runs. Conditional IF/THEN statements ensure that Biacore 3000 responds correctly to changes in run conditions. The most advanced software available enables detailed evaluation of results. Biacore 3000 is designed for individual sample characterization where the highest resolution in kinetic analysis is essential (see Figure 1) and for automation of multi-sample analyses (see Figure 2).

Superior performance for kinetic analysis Fig. 1a. Sample characterization Compound A001 A005 A006 A009 A010 A011 A012 A021 A025 A026 antipyrine atenolol B252 B268 B272 B274 B277 B295 B347 B369 B383 B384 B385 B400 B411 B412 cholic acid desipramine d-glucose dl-propranolol furoseimide hydrochlorothiazide iopanoic acid iophenoxic acid metoprolol naproxen nelfinavir phenylbutazone piroxicam quinine ritonavir salbutamol sulphadimetazine terbutaline tolterodine urea warfarin verapam II vx478 MW 539 539 574 570 655 562 538 635 659 674 188 266 777 614 356 370 519 603 614 652 650 719 599 667 562 857 409 302 180 296 330 298 571 572 649 230 664 308 331 324 721 239 278 274 325 60 308 491 506 Thrombin inhibitor (Hirudin 7000 Da) binding to immobilized thrombin. Concentration range: 1.25-160 nm Fig. 1b. Sample characterization Ab capture via RAMFc. Analyte = 4300 Da peptide 100 RU 3 RU Ideal for multi-sample analysis 25 22 19 16 13 10 7 4 1-2 blank -10 10 30 50 70 90 110 130 150 170 190 210 230 250 Biacore 3000 offers superior performance for kinetic analysis. Increased resolution is achieved by the highest signal to noise ratio, a high data acquisition rate and automatic in-line reference subtraction. Fig. 2. Multi-sample analysis Response (RU) 90 80 70 60 50 40 30 20 10 0-10 1 7 13 19 25 31 37 43 49 55 61 67 73 79 85 91 97 103-20 No. of cycles HIV 1 proteinase inhibitors at 10 µm in HBS-EP buffer with 1% DMSO (report point data). Threshold for positives Biacore 3000 is ideal for multi-sample analysis. In this example the automatic in-line reference subtraction and optimized wash routines ensured efficient screening of 49 low molecular weight (<1000 Da) compounds. Biacore 3000 ran 102 cycles within 39 hours.

Work with the high sensitivity Biacore 3000 can detect up to 70000 RU*, yet has a relative working range of as little as 10 RU. The ability to monitor biomolecular binding at this highest sensitivity ensures confidence in both the detection of binding events and in the interpretation of the related kinetic data. Figure 3 shows examples of the high sensitivity achieved with Biacore 3000. Fig. 3a. Direct detection of small molecules at < 1 nm concentration 4 RU buffer injection Thrombin inhibitor (Melagatran 420 Da) binding to immobilized thrombin. Concentration: 0.78 nm Fig. 3b. Increased resolution for kinetic analysis 15 RU Thrombin inhibitor (Melagatran 420 Da) binding to immobilized thrombin. Concentration range: 0.39-50 nm (duplicate injections). Lower concentrations can be tested by increasing the sample injection or contact time. Fig. 3c. Measurement of weak affinity binding events 1500 µm 20 RU 5.8 µm Req vs C plot Maltose (360 Da) binding to immobilized antimaltose antibody. Concentration range: 5.8-1500 µm (duplicate injection of each concentration). R K D 120 µm max18 RU Fig. 3d. Furosemide (0-10 µm) binding to carbonic anhydrase Resp. Diff. RU 30 25 20 15 10 * RU: Biomolecular binding events at a sensor surface cause changes in an SPR signal which are expressed in resonance units, RU (one RU is equivalent to one picogram of protein per square millimetre on the sensor surface). 5 0-5 -10-4 2 8 14 20 26 32 38 44 50 56 62 68 74 80 Time s

Measurements of kinetic and affinity parameters are always dependent on the experimental conditions as well as the molecular weights of the binding partners. Technical innovations in the design of the microfluidic pathway and detection system of Biacore 3000 ensure precisely controlled experimental conditions, as shown in Figure 4. Twice the signal can be generated for the same sample injection time compared to other Biacore systems. The microfluidic pathway of Biacore 3000 incorporates a single sensor surface overlaid by four flow cells, each with a volume of 0.02 µl. One flow cell can be used as a true reference during a single sample injection. Automatic in-line reference subtraction maximizes the resolution and information from a single run. The reduction of background noise will resolve signals which may not otherwise be observed. Fig. 4. Microfluidic system of Biacore 3000 housed in a temperature controlled environment elimination of air/liquid interfaces minimizes sample dispersion and protein denaturation analyte/buffer injection point sensor surface for immobilization (up to 4 different immobilizations are possible) 4 flow cells over one sensor surface single flow cell 0.02 µl flow cells used in series or individually automatic in-line reference subtraction, from same sample injection, using flow cell 2-1, 3-1, 4-1, 4-3 Four sensorgrams (one for each flow cell) and three reference subtracted curves can be displayed per single run. Flow cells 1-2 and 3-4 can be used as separate pairs for increased efficiency. All parameters which have been optimized in Biacore 3000, to achieve such superior performance in binding studies, are shown on the inside back page of this document.

Shorten analysis times System use may vary from a single sample run to unattended multi-sample runs over many hours. Biacore 3000 selects samples automatically from microplates or vials. Technical innovations in the microfluidic pathway shorten individual analysis times by halving the time previously needed to reach a satisfactory signal. Together with optimized wash routines between the runs this will, for example, save an estimated five hours in a 50 cycle run where each sample injection time is 5 minutes. More time can be saved by using conditional IF/THEN statements to enable Biacore 3000 to respond to pre-defined conditions, eliminating any unnecessary steps during a procedure (see section Develop specialized applications efficiently for more details). Automated in-line reference subtraction enables: fast visualization of the true response signal maximized resolution and information from a single run simplified evaluation processes Fig. 5. Assay setup wizard Fig. 6. Large reagent vial rack for unattended runs reagent and sample volumes handle microtitre plates change positions using the drag and drop option reagent rack A large reagent vial rack filled with the appropriate volumes ensures that the system can be left unattended to run all samples without the need to check on reagent levels. Biacore Wizards calculate the reagent volumes required for a programmed procedure.

-2000 P R O D U C T I N F O R M A T I O N Minimize sample consumption Samples used in binding studies are often valuable and available only in small quantities. Biacore 3000 requires sample injections from as little as 5 µl to monitor binding in all four flow cells. Each flow cell has a volume of only 0.02 µl. Technical innovations in the design of the microfluidic pathway reduces the amount of sample required to achieve a satisfactory signal. Biacore Wizards calculate minimum sample volumes required. Enhanced recovery and integration with mass spectrometry Surface-bound analyte can be recovered in high concentration in a defined volume of regeneration solution. Using the Analyte Recovery Wizard, MScompatible buffer is injected into the system prior to sample injection. Directly after this injection, the IFC (including the flow cell area), is flushed briefly with the same buffer. The autosampler and IFC (but not the flow cells) are further washed to prevent carry over prior to recovery of the bound analyte. The recovery is achieved by the passing of air segments over the flow cells for approximately 30 seconds before and after a 2 µl segment of recovery solution is incubated in the flow cells. After a user defined period, the 2 µl segment is drawn back into the autosampler and delivered to either a vial or a MALDI target. Response RU 4000 3400 2800 2200 1600 1000 400-200 -800 Running -1400 buffer Fig. 7a. Analyte Recovery Wizard guides the user through the process of analyte recovery and delivery Sample injection MS compatible buffer Wash Recovery Recovered material 0 200 400 600 800 1000 1200 Time s Fig. 7b. Sensorgram illustrating the main steps of an analyte recovery experiment run in Biacore 3000 with a sensor chip docked in the IFC. Wash here refers to a wash of the fluidic system and autosampler. Full information can be found in Technology Note 18 Analyte recovery in Biacore 3000: optimized functions for SPR-MS applications. This enhanced recovery functionality and design modifications now offer increased integration with mass spectrometry and increased capacity recovery of samples of interest. Automated recovery functionality is wizard supported to simplify and improve efficiency of recovery. Analyte recovery commands are optimized to allow elution in a smaller volume and of higher purity. Assays optimized to recover captured materials bound on the chip surface in a state suitable for further analysis such as MALDI-MS. Washing procedures optimized to minimize carry over from chemical substances and other proteins. The innovative Surface Prep Unit (Figure 7c) sitting in the autosampler of the Biacore unit provides increased analyte recovery. The surface area of 16mm 2 provided by the Flow Cell Carrier (FCC) type 2 is 3.3 times greater than the standard 4 flow cells of the IFC. Allows the user to optimize the surface to maximize bound analyte which is then automatically recovered and delivered as chosen in the wizard.

Integration with MS is achieved through direct deposition of recovered material to a MALDI target located in the autosampler area on a MALDI target holder (Figure 7d) (configured for Bruker MALDI targets). Wizard support for digestion of recovered protein after deposition into a vial or onto MALDI target Possibility to add matrix onto sample on MALDI target A simple MDL program to facilitate delivery of user defined digestion enzymes and MALDI matrix providing ultimate flexibility to suit mass spectrometrist s needs External Immobilization New external immobilization capability is also provided for immobilizations where reagents such as organic solvents are too harsh for the IFC. A second Flow Cell Carrier (type 1) is provided, creating 4 flow cells with the same surface area as those formed in the IFC. Once immobilization is complete, the chip can be inserted into the system for the assay to proceed. Fig. 7c. Surface Prep Unit and MALDI target holder in Biacore 3000 autosampler Study binding in non-aqueous and aqueous samples Biacore 3000 is used for samples ranging from small molecules to crude extracts, lipid vesicles, viruses, bacteria and eucaryotic cells. It may be necessary, for solubility or stability reasons, to work with specific additives, such as organic solvents or high salt concentrations. Technical innovations in the detection system of Biacore 3000 increase the dynamic range for sample measurements, enabling binding studies to be performed in a broad range of sample conditions (Figure 8a). Automatic in-line reference subtraction easily eliminates major refractive index effects. Examples include analyses performed in glycerol and DMSO environments (Figures 8b and 8c). The drop in signal level observed as the refractive index of a solution increases is due to a combination of the lower contrast between the refractive index of the sample and the running buffer and changes in the affinity characteristics. The broad range of sensor chip surfaces also enables selection of the optimal surface for the specific application. Fig. 7d. Direct depostion to MALDI target Dynamic range (RU) 70000 60000 50000 40000 30000 20000 10000 HBS 0 1.33 1.34 40% glycerol 6 M urea 2 M MgCl 2 15% DMSO 40% ethylene glycol 15% sucrose 1.35 1.36 1.37 1.38 1.39 1.4 Refractive index (RIU) Fig. 8a. Samples measured in a broad range of solutions Fig. 8b. DMSO environment. Iopanoic acid in 3% and 30% DMSO 3% DMSO 200 µm 100 µm 30% DMSO 200 RU 50 µm 200 µm 100 µm 50 µm Fig. 8c. Glycerol environment. Oligo, 9-mer, in 0, 20 and 40% Glycerol 200 nm 100 nm 50 nm 200 RU 0% glycerol 20% glycerol 40% glycerol 100 sec 100 sec Iopanoic acid (Mw 571 Da) binding to immobilized HSA. Iopanoic acid dissolved in HBS-EP buffer with 3% or 30% DMSO. Concentration range: 50-200 µm Hybridization of 9-mer oligonucleotide (Mw 2778 Da) to an immobilized biotinylated 10-mer oligonucleotide. 9-mer oligonucleotide dissolved in HBS with 0.5 M NaCl and 0, 20 or 40% glycerol. Concentration range: 50-200 nm

Use Biacore Wizards to simplify and accelerate analysis Biacore Wizards provide a fast and simple way of working with Biacore 3000, assisting and advising at every stage. Surface Preparation Wizard The Surface Preparation Wizard guides the user through the steps essential for preparation and testing of Sensor Chip CM5 and Sensor Chip SA. This Biacore Wizard: scouts for correct immobilization ph helps to find suitable regeneration conditions guides through ligand immobilization checks surface performance for reproducibility and baseline stability Fig. 10. Kinetic Analysis Wizard Wizard displays sensorgrams, fitted curves and apparent kinetic constants... Fig. 9. Select a Biacore Wizard...generates a trend analysis of baseline level......and generates results from control experiments Kinetic Analysis Wizard With knowledge of the assay principle and sample details, the Kinetic Analysis Wizard begins by recommending an experimental plan. This Biacore Wizard works throughout the kinetic investigation to: calculate and display apparent kinetic constants, sensorgrams and fitted curves generate trend analyses of baseline levels generate results from selected control experiments Preliminary data is immediately available after every run.

Binding Analysis Wizard The Binding Analysis Wizard is a tool for those working with experiments that require simple YES/NO answers for binding events. To provide an overview of the results, specified report points are presented as bar charts in which selected phases of each cycle can be displayed. Typical examples of experiments to study single pair or multi-molecular binding include: epitope mapping study of multi-molecular complexes use of enhancement or confirmatory reagents Develop specialized applications efficiently Fig. 11. Comparative results, displayed for each cycle, show YES/NO answers Biacore 3000 offers the flexibility to develop methods for applications in which modification of standard procedures are required to achieve the optimum results. Customized Application Wizard This Biacore Wizard provides programming flexibility when more demanding methods are required. Customized experiments are programmed at the push of a button. Fig. 12. Conditional statements Conditional Statements (IF/THEN) enable Biacore 3000 to respond correctly when specific predefined conditions are encountered. This can speed up analytical procedures by eliminating unnecessary steps, and the user can be sure that precious samples will be run only under satisfactory conditions. Examples of conditional statements are shown below: Speed up procedures IF response > 20 RU YES NO THEN regenerate before next cycle THEN begin next cycle Check surface conditions after regeneration IF baseline > 5 RU YES NO THEN repeat regeneration THEN begin next cycle IF baseline > 5 RU YES NO THEN stop method THEN begin next cycle

Method Definition Language Highly specialized applications on Biacore 3000 may occasionally require fully customized methods. The Method Definition Language gives the user the complete freedom to develop a customized method step by step. Perform advanced Kinetic evaluation Biacore 3000 includes options for the most advanced kinetic evaluation, and performs affinity or concentration calculations. The superior performance of Biacore 3000 together with the global fit functions of BIAevaluation software further extends the range for quantitative kinetic analyses, allowing confident interpretation of kinetic data within a 10 RU range (shown in Figure 13). Fig.13. Theoretical limits for kinetic analysis as a function of k a and molecular weight under recommended experimental conditions. Actual experimental results also shown. Kinetic information 10 10 k a 10 9 10 8 10 7 10 6 10 5 10 4 Very little kinetic information Quantitative kinetic analysis requiring numerical interation and global fit Quantitative kinetic analysis 10 3 10 2 10 3 10 4 10 5 10 6 10 7 M W flow rate: 30 µl/min Immobilized ligand Analyte MW Da (analyte) k a 1 Thrombin Melagatran 420 2 x 107 2 IgG z-fragment 8000 7.5 x 105 3 Anti-p24-Mab p24 24000 2.2 x 105 4 Epo-receptor Epo 21000 8 x 107 Evaluation Wizards, tool tips and pre-programmed models reduce the need for mathematical expertise and accelerate the evaluation of even the most complex interactions. Biacore 3000 ensures that methods and results are easily controlled, evaluated and reported.

For the best results in biomolecular binding studies 1. expert control 2. optimized monitoring 3. advanced evaluation Biacore systems use the phenomenon of surface plasmon resonance (SPR) to monitor biomolecular binding events in real time, without the use of labels. SPR occurs when surface plasmon waves are excited at a metal/liquid interface (the sensor surface). Light is directed at, and reflected from, the side of the surface not in contact with sample. SPR causes a reduction in the reflected light intensity at a specific combination of angle and wavelength (generating a refractive index dependent SPR signal). Lightsource Sensor chip with gold film Polarized light Prism Flow channel Reflected light I II Optical detection unit Molecules binding to the sensor surface cause changes in the refractive index close to the surface which are detected as changes in the SPR signal (expressed in resonance units, RU where one RU is equivalent to one picogram of protein per square millimeter on the sensor surface). In general, the refractive index change for a given change of mass concentration at the surface layer, is practically the same for all proteins and peptides, and is similar for glycoproteins, lipids and nucleic acids. Biomolecular binding events cause further changes in the refractive index and the SPR signal. Biacore 3000 is precisely controlled and primed to perfection to detect the smallest changes between a baseline signal and the signal generated when a second or third molecule interacts. 1. Control Expert control system to run standard procedures optimally, with single analysis times of typically 1-5 minutes Binding events displayed in real time for direct assessment of kinetic constants and immediate feedback Programming flexibility for specialized applications Automation to shorten analysis times and increase throughput Sample recovery for complementary analysis 2. Monitor Temperature controlled detection environment together with an increased data acquisition rate result in a high signal to noise ratio and provide a relative working range of as little as 10 RU 2a. Microfluidic system Flow cells designed for studies from small molecules to whole cells, using < 5 µl of sample Four flow cells over one sensor surface to allow in-line reference subtraction from the same sample injection and ensure perfect controls Elimination of air/liquid interfaces to minimize protein denaturation Continuous injection to maintain sample concentration and ensure accurate rate constant determination Option to immobilize up to 4 different molecules Simultaneous multichannel detection to monitor up to 4 different interactions in a single injection Option to use paired flow cells for increased efficiency 2b. Sensor surfaces A wide selection of sensor surfaces to maximize application flexibility Highest quality sensor surfaces to minimize non-specific binding and give excellent reproducibility 3. Evaluate The most advanced tools for sophisticated, rapid data evaluation

System specifications Sample handling: automated sample loading and injection Molecular weight detection: >180 Da Analytical performance Myoglobin*: 1 pm Flow rate range: 1-100 µl/min, through flow cell, steps of 1 µl Required sample volume: injected volume + 20-80 µl, depending on application Refractive index range: 1.33-1.40 Analysis temperature: 4-40 C (max 20 C below ambient) Number of flow cells: 4 (used individually, in series or as 2 pairs) In-line reference subtraction: yes (flow cell 2-1, 3-1, 4-1, 4-3) Dimensions (L x W x H): 760 x 350 x 610 mm Electric voltage: 100-120 V; 220-240 V Power consumption: max 580 VA Net Weight: 50 kg/110 lbs * Detection limits achieved with myoglobin MW 17 000 Da, measured with an antibody sandwich assay Ordering information Biacore 3000 system is delivered with processing unit, system controller, Biacore control, evaluation software, and Windows 2000 operating system. Please contact your local Biacore representative for specified information. Related products BIAevaluation Software Kit BR-1002-16 Related information Biacore Control Software Product Information Sheet BR-9001-28 www.biacore.com BR-9000-96 March 2003 Version 2.0