PROIECTAREA PRIN INTERMEDIUL UNUI SOFTWARE DEDICAT A INSTALAŢIEI ELECTRICE PENTRU UN IMOBIL A SOFTWARE DESIGN THROUGH ELECTRICAL SYSTEM FOR A BUILDING

Similar documents
A Comparative Study of Outdoor Lighting System Performance

Reducing Electricity Aquisition to Cover Internal Energy Consumption of Distribution Operators by using Photovoltaic Panels in 0,4kV Network

Project 2 : Integration with Design Studio 5 Lighting Analysis

REQUIRED RESIDENTIAL PERMITS

IMPROVING THE ENERGY EFFICIENCY BY REDUCING THE LOSSES IN THE LOW-VOLTAGE POWER DISTRIBUTION GRIDS

Comparable to 2D CFL:

Advertisements and information objects' positioning technologies based on the territorial zoning of the city of Tomsk

A Cover. lighting ENERGY EFFICIENT

RESIDENTIAL BUILDING REQUIREMENTS

2012 IRC Sections R303 R310 Building Planning II

NEWS LETTER MARCH 27, 2009

REHABILITATION OF A TIMBER TRUSS FROM THE ROOF OF TURDA THEATRE HALL

Residencial Vila Park - "Viviendas desde *. Plaza y Trastero Incluido" Avda. Mestral s/n,

INFORMATION GUIDE SECOND DWELLING UNITS BUILDING CODE BASICS

ARCHIVED. Compliance Document for New Zealand Building Code Clause G8 Artificial Light. Prepared by the Department of Building and Housing

stretchceilings.com.au

LIGHT YOUR IDEA. VarmaValo production FIN HAMINA, FINLAND

2018 IRC Sections R303 through R310 Building Planning II

Edificio Puerto Príncipe Pza. de Las Américas,

Via Parque Alicante BUILDING SPECIFICATIONS

The Alcalá Residential Development combines the peace and quiet of a residential area with the convenience of living in the city.

MCKINLEY INSTITUTE OF TECHNOLOGY BRAILSFORD & DUNLAVEY RGM AND ASSOCIATES MEASURE T BOND

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

Transience and Permanence: An Architectural Dialogue

LED lighting solutions based on Light Engines technology. Hervé Barcelo October 2011

Verification Methods For New Zealand Building Code Clause G8 Artificial Light

2015 WSEC: Electrical and Lighting Systems

Typical Finished Basement Details

ESSEX GUILD HOMES: 75 EASTWOOD ROAD, RAYLEIGH, ESSEX, SS6 7JN TEL NO:

Click to edit Master title style

CoreLine SlimDownlight - the clear choice for LED

Contractor/Owner initials are verification that items #1 and #2 and items (a) thru (g) above are included in the submitted plan/drawing.

Thermal insulation of old and new buildings in Romania

Chartered Membership Examination

Residencial Ciudad Jardín - Edificio Magnolia c/ La campanilla,

DEPARTMENT OF PLANNING SERVICES BUILDING INSPECTION DIVISION 1555 N 17 TH AVENUE, GREELEY, CO (970)

A Brighter Idea Than Fluorescent

BUILDING SPECIFICATIONS

Techno-economic Analysis of LED Lighting: A Case Study in

PART R3-L ZONE, LOW DENSITY MULTIPLE DWELLING DISTRICT

Basic Design Considerations for a Laboratory. The Ministry of Health & Family Welfare, under the Drugs & Cosmetics Act, laid down

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

CoreLine SlimDownlight - the clear choice for LED

General Building Information

Building Elements. Roof Wall. Slab/beam. Superstructure. Column. Basement. Substructure. Foundation

FRAMING INSPECTION GENERAL

The view of classroom light design optimization simulation Shijie Wang

Innovative LED Lighting that makes a big difference

Quality specifications for my home

DEVICES AND LUMINAIRES

Light is productive LS160. Now even more powerful and efficient

PRIMARK NEW WAREHOUSE FUTURE-PROOFED WITH ECO-FRIENDLY, INTELLIGENT LED LIGHTING

Urban Oasis BEAUTIFUL EHO

Hydrostatic Devices used for Construction of Seismic Energy Dissipation Systems

CARBON MONOXIDE ALARMS

The igtechnique: STEPS FOR DESIGNING

PLANNING, PROPERTY AND DEVELOPMENT DEPARTMENT. Construction requirements for LOWER LEVEL DEVELOPMENT. in residential dwellings

Jewel Vijayalakshmi Estates, Kesarapalli, Vijayawada

Lighting Applications for Industrial and Commercial Buildings

Third Party Design, Construction and Operations on FIU Campuses

Building Regulations; Construction 11

Mechanical Systems based on Dry Friction Force used for Building Isolation against Seismic Actions

RT-10 and RT-10N Districts Schedule

STRANDS AND STANDARDS

Daikin AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

DAIKIN AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

ENERGY STAR QUALIFIED PRODUCT INFORMATION FORM FOR INDOOR RESIDENTIAL LIGHT FIXTURES

DEVICES AND LUMINAIRES

Mayfair 16. Rainbow adapted the floor plan to suit our needs Cameron and Angela, Margate. Family living at the heart sq/m or 16.

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

SOUTH LODGE, PEMBROKE ROAD WOKING, SURREY GU22 7DP

CITY OF RICHMOND HEIGHTS DEPARTMENT OF BUILDING ZONING AND HOUSING STANDARDS AND REGULATIONS

City of Santa Monica Building and Safety Division

Product Overview Workplace Systems

Commercial Market Brochure General Line Products and Services

City of Edwardsville Safe Housing Program Rental Property Registration and Inspection. Rental Property Guide

SLL Masterclass 2013/2014 WILA. Energy Reduction Through Intelligent Lighting Design. Duncan Abbott MSLL

INDU LINE EFFICIENCY MADE AFFORDABLE LED ALTERNATIVE FOR T5/T8 LAMPS IMMEDIATE SAVINGS COMFORTABLE LIGHTING MAINTENANCE FREE

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

DMC SERIES MULTI-ZONE INVERTER AURORA HEAT PUMP SYSTEMS. 1.5 & 2 TON, 2 & 3 ZONE SYSTEMS Up to 17.9 SEER / Up to 12.5 HSPF / Up to 12.

LOT 25 Blueleaf Place. Brookfield $511,879 SUMMARY

DAIKIN AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

DAIKIN AURORA MULTI-ZONE HEATING & COOLING SYSTEMS

Custom Audio Designs Ltd

Communal 51 Ceiling Systems by Vogl

Short-Term Residential Rental Property Licensing/Inspection Program, Inspection Form/Checklist Ordinance No Chapter 6, Article 13A

Model Home 5 La Palma Bonaire

USE OF RENEWABLE ENERGY TO ENSURE THE THERMAL INDEPENDENCE FOR A LIVING BUILDING USING SOLAR HYBRID SYSTEMS

SPECIFICATIONS PROPOSAL & BID DOCUMENT. Sioux City, Iowa

AS/NZS 3000: 2018 Changes to Wiring Rules Standard

- Zone 1, 2, 21, 22 - Mechanical strength - Reliability over time - Instant, bright illumination

astral led Characteristics - luminaire Highly efficient modular LED lighting for closed areas options

Pulaski County, Virginia

IMPORTANT CODE UPDATE ENFORCEMENT DATE FOR NEW NATIONAL ELECTRIC CODE IS SET FOR MAY 1, 2013

Energy and Lighting Performance of Buildings in the Neighbourhood Ciudad de los Angeles, Before and After Refurbishing.

One and Two Family Additions

ANNEXE 1 : Renovation Specifications 2017 GENERAL CHRONOLOGICAL STEPS

PERFORMANCE STANDARDS

COMPLIANCE OVERVIEW. Module 2: Compliance Overview 4/6/2017 COMPLIANCE AND ENFORCEMENT

TAXABLE PAYMENTS FACTSHEET. If you run a business in the building and. construction industry then you ll soon need

Transcription:

Cornelia Victoria Anghel-Drugărin* PROIECTAREA PRIN INTERMEDIUL UNUI SOFTWARE DEDICAT A INSTALAŢIEI ELECTRICE PENTRU UN IMOBIL A SOFTWARE DESIGN THROUGH ELECTRICAL SYSTEM FOR A BUILDING Keywords: DiaLux v.4.11, design, electrical system, building, lighting lamp Cuvinte cheie: DiaLux v.4.11, proiectare, sistem electric, corpuri de iluminat Rezumat Proiectarea asistată de calculator a sistemelor de iluminat realizează dimensionarea unor instalaţii noi de iluminat cât şi verificarea celor existente, atât pentru sistemele de iluminat interior cât şi pentru sistemele de iluminat exterior. În proiectarea realizată s-a utilizat programul dedicat DiaLux versiunea 4.11. Abstract Computer aided design of lighting systems made new installations of lighting dimensioning and verification of existing lighting systems for both indoor and outdoor lighting systems. The design made to use program dedicated to DiaLux version 4.11. 1. INTRODUCTION Computer aided design of lighting systems involving specific knowledge and expertise in building design technology facilities (for power and protection of technological devices). Commencement of the design must be based on the design theme developed based on a study of necessity and opportunity of investment. Achieving efficiency requires completion of at least the following design criteria: - introducing the most modern projects and solutions-technological processes in the world of science and technology; - optimal sizing systems and equipment; - choice of solutions involving reduced consumption of materials; - inclusion in the draft assemblies standardized and standardized; - adopting those technological solutions that provide rational use of energy resources; - choosing green solutions, aesthetics, maintenance, ergonomics and high operational safety; - adopting those solutions that increase the productivity and to improve processes.

The main task of the designer is to determine how best to achieve low-voltage electrical installations. In the area of houses and office jobs, one of the most important conditions is related to providing comfort and ergonomics that is achieved through the provision of adequate facilities and aesthetic situations which contribute to peace and rest and relaxation on the one hand and to focus on the other. Also, the current information transmission that almost permanently to be put into doeth went to work in a dose that work-related effort so that using computers and telephony to expand close communication throughout the day. Thus we need almost anywhere, so by default for administrative units have access to the technical means necessary for this purpose: telephone, television, Internet, etc. An important aspect to be considered in residential complexes is based on the costs and depending on equipment or payback time. 2. APLICATIONS 2.1. Initial data about the project We considered a duplex house, consisting of living room, large type 1 room, type 2 large room, small room type 1 and small room type 2, bathroom, lounge, kitchen. For the considered property type and number of units for apartments rooms and hallways analyzed are shown in the table below: Tabel1. Type and number of units for apartments rooms and hallways. Area Device/ Light source [buc] No Lamp Monopolar intreruptor Bipolar Swicher Head Scale Swicher Monophasic sochets 1 Hallway access 1 1-2 1 2 Hallway1 ground 2-1 2 1 floor 3 Hallway2 ground 2-1 2 1 floor 4 Hallway1 level1 2-1 2 1 5 Hallway2 level1 2-1 2 1 6 Porch 1 1-1 1 7 Stairs ground 2 - - 2 1 level to level1 8 Stairs 2 - - 2 1 9 Central corridor 2-1 - 1 floor 10 Garage 2-1 - 1 11 Storage 2-1 - 1 12 Bedroom 1 1 1 1-3 Small room t 1 2-1 - 2 Living type 1 3-1 - 3 Bathroom 1 1 1 - - - Kitchen type 1 2-1 - 2 13 Bedroom type 2 2-1 - 3

21 Small room t 2 2-1 - 2 Big room tip 2 3-1 - 3 Bathroom tip 2 1 1 - - - Kitchen tip 2 2-1 - 3 Bedroom 3 tip 1 2-1 - 2 Bedroom3 tip 2 2-1 - 2 The main parameters and coefficients necessary to calculate the lighting system (measured or taken from the rules) stated: - the reflection coefficient; - for the ceiling: concrete materials plastering or matte paint (possibly applied to plasterboard) pt = 0.5; - for the Walls with similar characteristics, possibly coverings: ρp =0.5 or pp = 0.3; - ambient lighting for living spaces are E med = 50 Lx for rooms, for hallways E med = 75Lx, for main spaces E med = 20 Lx and E med = 100 LX for annexes and offices. 2.2. Applying the coefficient of Use method For dimensioning the lighting of the rooms and spaces with special lighting, strict requirements and utilization coefficient method is applied. This method is used for symmetric luminaries of the same type placed at a height equal to the plane manner. Utilities of the rooms and hallways are considered the height h u = 1,6 m located approximately at eye level for the displacement situation. Luminaries with light sources are placed symmetrically keeping the rooms and building elements to furniture, ensuring a certain aesthetic in accordance with the wishes of the beneficiary. Distance suspension and fixation is given room size and length measurements resulting from power conductors. The necessary data are summarized in tables. Consider the following hypotheses: - reflection coefficients of the ceiling and walls are considered constant; - reflection coefficients of furniture is ignored. The coefficient of utilization is the ratio of flow u manner that it falls on the surface of Φ u and the total flux emitted by the source Φ t : Φ E med Su K u u = = Φ t Nc n Φl where: - E med is average luminance imposed on useful plan; - S u = A B represents horizontal area of the space to the useful plan; - K is depreciation coefficient that takes into account the decrease over time of lamp lumen maintenance intervals and lighting installation; - N c is the number of lighting in a room that will be established according to the preference beneficiary; - n is the number of lamps is fitted luminaries lamp; - Φ l is the luminous flux of a lamp (500...600 lm for our study case).

Utilization coefficient is an overall yield of actual use of the flow of light sources useful plan. As the height h over the useful plan is higher, such as the solid angle which includes the surface of the falling flow capacity is lower and the rate of use is lower. h = H (h u + h a ) The size of the previous formula have the following meanings: - H is the total height of the rooms (results of measurements and presented and summarized in the table) - h u is the utilities room height,which is noted h u = 1,6 m in our study case - h a is the distance from the top of the suspension or fitting room lighting; h a = H h, where h is the height of suspension or mounting luminaries lamp established based on user requirements The surface of the rooms in the useful plane is calculated as follows: - for the large room type 1: S = A B = 4,8 4,2 = 19,2m 2 - for hallway landing: S = A B = 5,8 1,6 = 22,2 m 2. 2.3. Implementation with CAD for light systems DiaLux, version 4.11 DIALUX 4.11 version, European software program, is dedicated to the design of lighting systems used by major manufacturers in the industry. The software can be free downloaded from SC Elba sitetimişoara. The software is applicable to: interior lighting system (offices, warehouses, commercial), external light (commercial spaces, monuments, parks, sports fields), or on the road (streets, intersections). The program is useful for sizing interior lighting and areas having the following functions and structure: - New lighting project type - Characteristics of the room or area, - User choice reflectance in a room - Selection of light sources and lighting-database; - Location lighting; - Recommended lighting levels for various indoor destinations; - Surface and calculation points; - Calculations, average and spot lighting; - Save Data; - Print results.

C.4 C.5 C.6 C.7 D11 D4 D5 D6 D7 D12 D3 C.3 TS4 CYYF- 3 6 mm 2 D8 C.8 C.2 D2 C.1 D1 TP 1 TP 2 TD D10 CYYF- 3 10 mm 2 C.10 MYYF- 3 25 mm 2 D9 C.9 LEGENDA - Bloc de măsură şi protecţie - Tablou general de distribuţie - Tablou principal de alimentare - Doze principale legătură cameră BMPM MYYF- 5 32 mm 2 Spre PA Figure 1. Sizing wiring diagram in the building. The scheme of our building are 0.4 kv electrical install. Also on the schedule is noted and sectioning system. The whole plant is placed under the plaster hoses. The wires used were dimensions 5X32 mm 2 3x25 mm 2 3x10 mm 2 and 3x6 mm 2 and power plants belong. Figure 2. Inserting values necessary for space and choice of mounting bodies and their types.

Figure 3. Calculating different settings of lighting and checking results. Finally mutually agreed with the customer, location and placement of lighting outlets are established. CONCLUSIONS Building energy management system uses tracking interconnection means contributing to the development and implementation of intelligent building concept ensuring an optimal energy management thereof. It was considered a duplex house consisting of living room, large room type 1, large room type 2, small room type 1 and small room type 2, bathroom, lounge, kitchen. The design of the electrical installation was performed with dedicated software Dialux version 4.11. References 1. BIANCHI, C ş.a.- Proiectarea instalaţiilor electrice de iluminat, Ed. Tehnică, Bucureşti, 1984 2. CIOBANU, L - Instalaţii electrice de joasă tensiune. Elemente de audit şi domotică, Ed. MatrixRom, Bucureşti, 2004 3. *** Normativul I 7/1998/2002 privind proiectarea şi executarea instalaţiilor electrice la consumatori cu tensiuni până la 1000 V. * PhD Eng. Cornelia Victoria Anghel-Drugărin Eftimie Murgu University of Reşiţa, Electrical Engineering and IT Department, Computer Science Technology, c.anghel@uem.ro, vicepresident ACM-V Caras-Severin Region, Romania.