BUILDING STRENGTH ACCUBRACE TOTAL BRACING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS

Similar documents
Brace Badger Helical Anchor System. MB Badger Advantages Installation Requirements MB Super Braces Brace Attachment Criteria.

DANGER. Falling Panels, Bracing or Hardware Can Cause Property Damage, Severe Injury or Death.

Interior Hangers. Application

Garage Beam System DAYTONSUPERIOR.COM FORMING. For Post-Tensioned Beam and Slab Parking Structures

Symons Soldier DAYTONSUPERIOR.COM FORMING. Versatile Soldier Beam System

AREMA C&S Manual 2018 (Includes 2018 Revisions) Volume 4 Index SECTION 14 - ELECTRICAL DEVICES, FOUNDATIONS, HARDWARE

Standard Duty Cantilever Rack Installation and Assembly Guide

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

Tilt-up Products & Engineering Support. MeadowBurke

Masonry Wall Bracing. A Simplified Approach To Bracing Masonry Walls Under Construction. Masonry Bracing Task Force.

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

BROCHURE. Steel Forming System. A durable, all-steel forming system that is ideal for pier caps and self-spanning applications. DAYTONSUPERIOR.

DeckFast DAYTONSUPERIOR.COM FORMING. Shoring System

TILT-UP LIFTING PRODUCTS

Installation and Maintenance Manual for EMH Freestanding Workstation Jib Cranes

COLLECTIVE POSITION ON SAFE REMOVAL OF TEMPORARY BRACES

CANTILEVER RACK SPECIFICATIONS PART 1 GENERAL 1.1 SCOPE 1.2 APPROVED MANUFACTURER 1.3 REGULATORY ORGANIZATIONS AND GROUPS 1.4 QUALITY ASSURANCE

Model # 600H-D. 4/2/2012 Page 1 of 6

Model # 612H. 7/11/2016 Page 1 of 6

Model # 362S-RDP. 9/17/2012 Page 1 of 12

Strengthened Soil Wall Construction Manual

STANDARDIZED STRUCTURES

SECTION ALTERNATING TREAD ALUMINUM STAIRS

Com-Tray. Under Floor

Site Preparation... 2

Residential Deck Safety, Construction and Repair. Juneau Permit Center, 4 th Floor Marine View Center,(907) February 2016

SAFETY SYSTEM. G-Deck Consideration. Manual Handling

ROAD CLOSURE GATE PLAN ESTIMATED QUANTITIES CONCRETE FOOTINGS FOR S. D. DEPT. OF TRANSPORTATION DECEMBER 1996 ELEVATION CABLE TIE DOWN FOOTING

210 Series UL Listed Modular Vault Panel Installation Procedures January 15, 2009

Model # 158-P4. 12/12/2013 Page 1 of 11

SECTION 552 HELICAL ANCHORS AND HELICAL PILES

Smarter. Safer. Leaner.

Model # 238HS-P8. 4/27/2011 Page 1 of 11

MECHANICAL LEVELERS. P.O. Box 338 Spring Hill, Tennessee /486/ /251/3382 Fax 931/486/0316

Miscellaneous and Cast Iron Listings

FrameFast Shoring System

SECTION ALTERNATING TREAD STEEL STAIRS

SECTION CRL50 AND CRL51 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Structural Cantilever Installation Manual

SECTION ELEVATED BLEACHERS (Angle Frame Semi-Closed Deck)

SECTION CRL70 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

HANDSET WALL FORM. Handset Wall Form. Quick Assembly - can be built using only a hammer. Reduced weight increases productivity

SECTION HANDRAILS AND RAILINGS. A. Section Metal Fabrications: Associated metal supports.

THE SASKATCHEWAN CODES OF PRACTICE GAS INSTALLATION SUPPLEMENT CSA-B PROPANE STORAGE AND HANDLING CODE

Drawing Modification Summary Effective:

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

SafeDeck Supported Scaffold System

Imperial. folds. Wall braces are attached to the multifunction. guard-railing post. Formworkprop. connectors and flange screws.

ALISPLY. Scaffold Plank. Aligner. Plate Washer ½ x 6 x 6

Model #369S-RDP. 8/23/2016 Page 1 of 11

Cantilever Loading Platform Erection Procedures and Guidance Notes

T-WALL Retaining Wall System

SECTION VIBRATION CONTROLS FOR HVAC PIPING AND EQUIPMENT

See the IRC for additional information. See CPD-DS Information Bulletin 100 for Requirements for 1 & 2 Family Dwelling plan submittals.

Mounting systems for solar technology

INSTALLATION GUIDE PLEASE READ ENTIRE INSTRUCTION MANUAL BEFORE PROCEEDING!

SECTION ORNAMENTAL ALUMINUM RAILING

Installation Manual. ArchCast Bridge. 3-Sided Precast Concrete Bridge Structure

1675 Locust Street Red Bud, IL Phone: Fax: WARRANTY & TERMS

Model # 358PS-RDP. 12/13/2013 Page 1 of 12

Atlas Column Forms COLUMN FORM SYSTEMS MULTI-CHANNEL AL-SPEED

SECTION ALUMINUM WALKWAY COVERS. A. The requirements of Division 1 specifications shall apply to work specified in the section.

SECTION EZ-SLIDE 80 AND 180 HEAVY GLASS TOP HUNG SLIDING DOOR SYSTEMS

Wall Panels. Structural wall panel. Architectural wall panel. Cladding wall panel. Sandwich wall panel

Universal Panels & Accessories

Model # 940S-P6-BB. 6/7/2017 Page 1 of 10

OWNER S MANUAL SERIES MDS-96-BK, SM, DR

3/21/2012. Dave Conkel State Aid Bridge Engineer. Brian Homan State Aid Bridge Plans Engineer

Leveling Foot RB210. Leg Extender RLT66

ITEM 555 CHAIN LINK FENCING

Fabricate and Install metal alternating tread stair assemblies in accordance with the requirements set forth in this section.

Structural Breadth Study

Chuck Brooks, P.E., P.Eng. C&S Engineers

Acrow V-Shore Formwork System

Model #369S-PR. 8/23/2016 Page 1 of 11

Design & Detail Installation Manual. LongSpan Bridge and Culvert Construction System

REV. 9/08. Mounting Structure PRE-INSTALLATION GUIDE for Ergon Skybooms

Elevated Slab Sequence

ASSEMBLY INSTRUCTIONS RESIDENTIAL SOLUTION CROSSRAIL GROUND MOUNT SYSTEM USA

Model # 800SM-PS3. 8/3/2016 Page 1 of 8

Modular Scaffold MEKA 48

Student Services & Classroom Addition

Aluma EasySet Continuing Innovation from Aluma S ystems

Pre-Cast Machine Bases

SECTION ALTERNATING TREAD STEEL STAIRS

Model #369SM-RDP. 8/23/2016 Page 1 of 10

Model # 338S-RDP. 7/31/2012 Page 1 of 13

PERFORM WITH PRECISION BOX CULVERT TRAVELER CONCRETE CONSTRUCTION PRODUCTS APPLICATION GUIDE

Abu Dhabi EHSMS Regulatory Framework (AD EHSMS RF)

louisville ladder PUMP JACK GUIDE BECAUSE WORK AIN T PLAY.

Assembly and users manual. Pallet racking Alfa

SECTION CLIMBING WALLS

Model # 940PPS-V3. 2/12/2014 Page 1 of 10

Model # 358PS-OP. 12/13/2013 Page 1 of 12

1. Include plans, elevations, sections, details, and attachments to other work.

BY DAYTON SUPERIOR. FormRight FORMING SYSTEM

Draft. Not yet Approved

Page 10-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 LIGHTING AND SIGNS

Mechanical Engineer of Record: (Smoke Control Systems Only) Name & License Company. Others: Responsible Party Name & License Company

CANADIAN MANUFACTURED PALLET RACKING OUR STRENGTH IS OUR PRODUCT ROLLFORMED RACK

Transcription:

BUILDING STRENGTH ACCUBRACE TOTAL BRACING SYSTEM CONCRETE CONSTRUCTION SOLUTIONS

A Total Bracing System An integrated, in-line total bracing system designed to decrease labor costs and increase project efficiency. The Accubrace Total Bracing System is designed for rapid installation and the ability to immediately load the helical ground anchor for unsurpassed speed and efficiency on any tilt-up or precast project. Bracing products are warehoused at regional offices and can quickly be transported to job sites. Custom braces can also be designed and manufactured to meet any project application. Dayton Superior provides safe engineered solution by installing helical ground anchors and renting necessary components. FEATURES AND BENEFITS: Helical Ground Anchors are engineered alternative to concrete deadmen and/or floor slabs - reducing the associated time and labor costs Rapid, all-weather brace installation immediate loading when used with the helical ground anchor Remove and relocate ground anchors if installation of braces requires adjustment Anchor location is adaptable can be installed inside or outside of structure Bracing on the outside of wall simplifies structural steel erection especially in multi-story buildings Bracing on the inside of wall eliminates holes in floor slab and vapor barrier Integrated in-line connection to the brace utilizing a Helical Ground Anchor (HGA) and Transition Brace Connector (STBC) Dayton Superior offers Professional Engineer review and stamp services Removable and reusable HGA can be used with any type of brace Reduces the number of braces needed if HGAs used with high capacity braces 2 WWW.DAYTONSUPERIOR.COM

Components Overview Accubrace hardware connectors for braces and helical ground anchors serve as load transfer mechanisms. These connectors are an integral part of the total bracing system. WARNING: Welding, cutting, or any modification to the HGA, STBC connector, brace, or components is strictly prohibited. Helical Ground Anchors and HGA Extensions Helical Ground Anchors are engineered alternative to concrete deadman and/or floor slabs Dayton Superior installs, removes, and rents HGAs, and provides documentation for each HGA installed A geotechnical review prior to the installation date is recommended, and included with the service Contractor is responsible for preparing the HGA layout prior to crew arrival Certain sites with lower strength foundation soils may require HGA Extensions. HELICAL GROUND ANCHOR (HGA) KEY: 7' (MIN.) TRANSITION CONNECTOR HELICAL PLATES B Brace length W Brace connection height above bottom of panel H Panel height BRACE ANGLE GROUND LINE PANEL WALL BRACE X G FOOTING SLAB TOP OF FOOTING ELEVATION HGA Mark - Horizontal distance from panel face HGA elevation +/- relative to panel bottom HGA Extension Helical Ground Anchor (HGA) (Above) Installation of HGA. (Left) HGA installed and ready to accept wall braces to support concrete wall panels. Building Strength 3

Transition Brace Connectors and Braces Standard Transition Brace Connector New Brace Name Former Brace Name The Standard Transition Brace Connector (STBC) STBC quickly connects the brace to the HGA with center-line alignment Use 5 8" Grade 8 L Pin to connect STBC to brace and ¾" Grade 8 L Pin to connect STBC to HGA Alternative Method: use 5 8" full shoulder Grade 8 bolt with locking nut to connect STBC to brace and ¾" full shoulder Grade 5 bolt with locking nut to connect STBC to HGA Braces HGA can be used with any Dayton Superior brace. Square Braces Outside Dim. Std. Brace Brace Min. Brace Max (Above and Below) Standard Transition Brace Connector, Alternate Method Ultimate Load** (Lbs) Brace Weight* (Lbs) B21R23S B21F 4.0" 21' 21'-0" 23'-3" 23,250 230 B27R36S B27BF 5.0" 27' 25'-7" 27'-3" 36,000 350 B32R24S B32F 5.0" 32' 30'-9" 33'-3" 24,375 405 B33R22S B33F 5.0" 33' 31'-9" 34'-3" 22,500 410 NOTES:* Does not include weight of connectors. ** Ultimate Load based on adequate brace to HGA or slab connection. Round Braces New Name Type Description Min Max Ult. Load **** (Lbs) Brace Wt. (Lbs) BA0814R B1A Short Pipe Brace 8'-0" 14'-0" 9,750-5,625 87 BA1423R B4 Heavy Duty Regular Pipe Brace 14'-6" 23'-6" 9,750-2,525 130 BA2239R B5*** Heavy Duty Long Pipe Brace 22'-6" 30'-10" 8,962-2,025 208 B17R13R B7 Short Jumbo Brace 16'-3" 17'-9" 13,050 107 B22R9R B8 Jumbo Brace 21'-3" 22'-9" 9,750 130 B22+5R7R B9 Jumbo Brace with 5-0" Ext. 26'-3" 27'-9" 7,200 172 B22+10R5R B10 Jumbo Brace with 10'-0" Ext. 31'-3" 32'-9" 5,400 193 BA2540R B11 Tru-Itt Brace 25'-6" 40'-0" 13,500 505 B32R13R B12A Jumbo 5-1/2" 31'-3" 32'-9" 13,500 245 B27R18R B13** Jumbo 5-1/2" 26'-3" 27'-9" 18,000 237 B32+10R7R B14* B12 Jumbo Brace, 10'-0" Ext. 41'-3" 42'-9" 7,800 382 B32+20R5R B15* B12 Jumbo Brace, 20'-0" Ext. 51'-3" 52'-9" 5,700 410 BA32+5R12R B16 B12 Jumbo Brace, 5'-0" Ext. 36'-3" 37'-9" 12,000 360 B42R19R B17A Super Brace 41'-3" 42'-6" 19,000 613 B52R19R B18 Super Brace 50'-6" 52'-2" 19,200 984 Notes: * Field assembly is required for B14 and B15 braces. Fixed length allows for +/-9" of adjustment except B17A brace has +/-7.5" of adjustment and B18 Brace has 11.75" of adjustment on each end. Pipe Extensions: T15 for the B8 model and T20 for the B12 model. ** B13 is Made To Order brace. *** B5 Brace Maximum is 39'-0", but a Knee Brace is required over 30'-10". **** Ultimate Load based on adequate brace to HGA or slab connection. 4 WWW.DAYTONSUPERIOR.COM

Wall Panel Connection Brace-to-Wall Panel Connection: Standard Wall and Floor Plate Braces standard on most round braces Two-hole wall plate for higher loads standard on B11 and B18 braces Optional four-hole AWPP1 foot plate Use T13 post installed brace anchor or T6A, T6S, T5A, T5A HVY brace inserts to connect wall plates to wall panels Standard Wall and Floor Plate Bracket Two-Hole Foot Plate Bracket T6A Wall Brace Insert T5A Inverted Wall Brace Insert T13 Tang Bolt PCN Description SWL 139721 Standard HGA ( 1-1/2" Square Bar with 10" Helical Plates) 12,000 lbs 7'-0" 139718 Std. HGA Extension ( 1-1/2" Square Bar with 10" Helical Plates) 15,000 lbs 4'-0" 139722 Standard Transitional Brace Connector (STBC) 15,000 lbs 122514 Standard Wall and Floor Plate Bracket 100068 Single-Hole Wall and Floor Plate Bracket for B42R19R (B17A) 121954 Two-Hole Wall and Floor Plate Bracket for BA2540R (B11) and Accubrace Braces 146283 Two-Hole Wall and Floor Plate Bracket for B52R19R (B18) braces 139717 Four-Hole Wall and Floor Plate (AWPP1) - optional 49206 T13 Coil-Anchor with Tang (3/4" x 4-1/2") 123045 T13 Coil-Anchor with Tang (3/4" x 6") NOTES: When an extension is used, the working load of the HGA increases to 15,000 lbs for the installed torque of 2,200 ft-lb Safe Working Load is based on 2:1 Safety Factor Building Strength 5

Transitional Brace Connector Installation Installation: 1. REMOVE the brace shoe. 2. Use the approved Dayton Superior Standard Transitional Brace Connector (STBC). 3. Attached STBC to the brace using 5/8 Grade 8 L pin with locking cotter pin or 5/8" Grade 8 bolt with locking nut. 4. Attach STBC to HGA using 3/4" Grade 8 L pin with locking cotter pin or 3/4" Grade 5 bolt with locking nut. CORRECT Brace-to-HGA Connection INCORRECT Brace-to-HGA Connection WARNING: DO NOT attach brace to Helical Ground Anchors using the brace shoe. This connection is not approved by Dayton Superior. 6 WWW.DAYTONSUPERIOR.COM

Accubrace HGA Installation Services Steps for a Successful Installation Provide Dayton Superior with least five business days notice to mobilize its equipment and crews to the project site. A Geotech review prior to the installation date is recommended, and included with the service. Please note that a Geotech report covers less than 1% of the project foot print, and is only an indication of soil conditions. Unfavorable conditions are always a possibility. Contractor is responsible for preparing the HGA layout prior to crew arrival. Layout includes: Marking the horizontal distance from the panel face to the HGA location. Minimum 3' clearance from top of HGA to casting slab or other obstacle. Contractor to advise Dayton Superior representative of any changes to panel book HGA elevations. Contractor is responsible for location of any underground utilities. Any subsurface structure or utility near the anchor locations shall be clearly marked. WARNING: Installation of anchors underneath utilities or subsurface structures is strictly prohibited. HGA marks need to be free of debris and accessible by a skid steer. The contractor is to undergo preventive measures to mitigate soil erosion adjacent to installed anchors. Contractor is responsible for lost and damaged HGA. Dayton Superior recommends flagging the HGAs when the braces have been removed to avoid damage and loss. Dayton Superior needs the cell phone number and/or email address for the onsite Superintendent. Dayton Superior will confirm with on-site Superintendent the day prior to the HGA installation Dayton Superior will coordinate the arrival of the HGAs and/or braces with the on-site Superintendent as third-party shipping is the normal delivery method. Dayton Superior will band the HGAs as they are removed, and load if the contract carrier is available. If not available, will stack as directed by onsite Superintendent. If braces are supplied with the HGAs, contractor is responsible for properly stacking braces for the return transportation. Building Strength 7

1125 Byers Road Miamisburg, OH 45342 937-866-0711 888-977-9600 BUILDING STRENGTH Copyright 2018 Dayton Superior Corporation, All Rights Reserved.