EVALUATION REPORT. PFC-5551 Reissued April 1, Filing Category: DESIGN Steel (038)

Similar documents
DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: CANTSINK MANUFACTURING, INC. 71 FIRST AVENUE LILBURN, GEORGIA 30047

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: EMPIRE PIERS 2656 EAST HWY 47 WINFIELD, MO EVALUATION SUBJECT:

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GOLIATHTECH INCORPORATED 175B RUE PELADEAU MAGOG, QUEBEC J1X 5G9 CANADA

ICC-ES Evaluation Report Issued August 1, 2011 This report is subject to renewal in one year.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: IDEAL MANUFACTURING, INC. 999 PICTURE PARKWAY WEBSTER, NEW YORK 14580

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: GEOTECH ENTERPRISES, INC.

*Corrected, April 2001

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: MACLEAN POWER SYSTEMS CIVIL PROUCTS (MPS CIVIL) CORPORATION

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: MAGNUM PIERING, INC. 156 CIRCLE FREEWAY DRIVE CINCINNATI, OHIO 45246

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: HELICAL ANCHORS, INC BOONE AVENUE, NORTH MINNEAPOLIS, MINNESOTA 55428

Legacy report on the 1997 Uniform Building Code, the 2000 International Building Code and the 2000 International Residential Code.

Originally Issued: 05/18/2018 Valid Through: 05/31/2019

ICC-ES Evaluation Report Issued February 1, 2011 This report is subject to re-examination in one year.

DIVISION: EARTHWORK SECTION: BORED PILES REPORT HOLDER: TECHNO-PIEUX INC. EVALUATION SUBJECT:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL WALL PANELS REPORT HOLDER: FCP, INC.

Page 7-1 Hubbell Power Systems, Inc. All Rights Reserved Copyright 2014 DRAWINGS & RATINGS

Trusted ICC ES TEK USA, Evaluation. report, or as to any. ICC-ES Evaluation

SECTION 552 HELICAL ANCHORS AND HELICAL PILES

LEGACY REPORT ER-5608* Reissued February 1, Legacy report on the 1997 Uniform Building Code

Product Evaluation Report

DIVISION: MASONRY SECTION: CONCRETE UNIT MASONRY REPORT HOLDER: 3B CONSTRUCTION SOLUTIONS, INC.

*Corrected October 2005

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: QUALITY WAY PRODUCTS, LLC 407 HADLEY STREET HOLLY, MICHIGAN 48442

INTERNATIONAL ASSOCIATION OF PLUMBING AND MECHANICAL OFFICIALS UNIFORM EVALUATION SERVICE EVALUATION CRITERIA FOR

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: METAL ROOF PANELS SECTION: METAL WALL PANELS REPORT HOLDER:

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: SAS STRESSTEEL INC. 100 NEW DUTCH LANE FAIRFIELD, NEW JERSEY 07004

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD.

ESR ICC Evaluation Service, Inc. Reissued July 1, 2006 This report is subject to re-examination in two years.

DIVISION: METALS SECTION: METAL FABRICATIONS REPORT HOLDER: AKRON PRODUCTS COMPANY

ACCEPTANCE CRITERIA FOR THREADED HIGH-STRENGTH STEEL BARS FOR CONCRETE REINFORCEMENT PREFACE

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: DEXTRA MANUFACTURING CO., LTD. EVALUATION SUBJECT:

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

Originally Issued: 01/16/2015 Revised: 09/20/2018 Valid Through: 01/31/2019

Originally Issued: 01/16/2015 Revised: 01/30/2018 Valid Through: 01/31/2019

REPORT HOLDER: FASTENING SPECIALISTS, INC. 726 CENTRAL FLORIDA PARKWAY ORLANDO, FLORIDA EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER: MITEK USA, INC.

MODEL SPECIFICATIONS: Hydraulically Driven Steel Underpinning Pile Specifications

ACCEPTANCE CRITERIA FOR HELICAL PILE SYSTEMS AND DEVICES PREFACE

ICBO Evaluation Service, Inc Workman Mill Road, Whittier, California

SHORING & UNDERPINNING 02250

CITY OF LOS ANGELES CALIFORNIA

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: FOUR SEASONS BUILDING PRODUCTS, LLC

ACCEPTANCE CRITERIA FOR HELICAL FOUNDATION SYSTEMS AND DEVICES PREFACE

LEGACY REPORT ER ICC Evaluation Service, Inc. Reissued January 1, Legacy report on the 1997 Uniform Building Code

DIVISION: METALS SECTION: STEEL DECKING REPORT HOLDER: EPIC METALS CORPORATION 11 TALBOT AVENUE RANKIN, PENNSYLVANIA 15104

ICC-ES Evaluation Report Reissued March 2014 This report is subject to renewal May 1, 2015

REPORT HOLDER: BLUE POINT FASTENING, INC YORBA COURT CHINO, CALIFORNIA EVALUATION SUBJECT:

ACCEPTANCE CRITERIA FOR HELICAL PILE SYSTEMS AND DEVICES PREFACE

Evaluation Report CCMC R HELICAL PILE

DIVISION: CONCRETE SECTION: REINFORCING STEEL REPORT HOLDER: BARSPLICE PRODUCTS INC WEBSTER STREET DAYTON, OHIO

ACCEPTANCE CRITERIA FOR EXPANSION BOLTS IN STRUCTURAL STEEL CONNECTIONS (BLIND-BOLTS) PREFACE

SPECIFICATIONS - DETAILED PROVISIONS Section Stainless Steel Sluice Gates C O N T E N T S

05510: TAPERED STEEL TROLLEY POLES AND ACCESSORIES

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 5000 SERIES FASTENERS

PER See all Pei ES Listings at: Report Owner

1. Cast-in-place concrete is specified in Section

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Flotation Docking Systems, Inc.

Evaluation Report CCMC R ALMITA HELICAL SCREW PILE

CITY OF LOS ANGELES CALIFORNIA

MICHIGAN DEPARTMENT OF TRANSPORTATION SPECIAL PROVISION FOR LOW-TENSION CABLE BARRIER. OPR:CT 1 of 5 APPR:JAR:DBP: FHWA:APPR:

NORTH HARRIS COUNTY REGIONAL WATER AUTHORITY PIPE HANGERS, Section PIPE HANGERS, SUPPORTS, AND RESTRAINTS

Facility Repairs - MCAS Cherry Point - Tank Farm A SECTION STRUCTURAL STEEL 05/14

Originally Issued: 04/01/2016 Revised: 05/01/2017 Valid Through: 04/30/2018

3.1 General. 3.2 Materials. 4.1 General. Page 1 of 6

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA TOWSON, MARYLAND EVALUATION SUBJECT:

UNISTRUT CORPORATION GENERAL NOTES 1. THIS UNISTRUT SUPPORT SYSTEM IS DESIGNED TO SUPPORT A MAXIMUM UNIFORM LOAD OF PSF.

1. Base plates, setting plates and anchor rods for columns. 8. Lintels if connected to structural steel columns.

REPORT HOLDER: MITEK USA, INC. (FORMERLY USP STRUCTURAL CONNECTORS) SOUTHCROSS DRIVE, SUITE 200 BURNSVILLE, MINNESOTA EVALUATION SUBJECT:

REPORT HOLDER: AEROSMITH FASTENING SYSTEMS 5621 DIVIDEND ROAD INDIANAPOLIS, INDIANA EVALUATION SUBJECT: AEROSMITH 3000 SERIES FASTENERS

RB WEIR GATES MODEL GENERAL DESCRIPTION DESIGN CONSTRUCTION

ICC-ES Evaluation Report Issued October 1, 2013 This report is subject to renewal October 1, 2014.

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT:

ADDENDUM No. 6. ITB No. 4424: W.R. Wheeler (Swift Run) Service Center PUD Non-motorized Improvements Phase 1

ICC-ES Evaluation Report. ESR-3342 Reissued July 1, 2013 This report is subject to renewal August 1, 2015.

ESR ICC Evaluation Service, Inc. Reissued January 1, 2008 This report is subject to re-examination in one year.

TERRATORQUE HELICAL ANCHORS AND HELICAL PILING PRODUCT CATALOG

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PJ S REBAR INC.

For Anchors, Frame Ties, Steel Piers, & LLBS Support Systems

LEGACY REPORT DIVISION: WOOD, PLASTICS AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

STANDARDIZED STRUCTURES

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES SECTION: REINFORCING STEEL REPORT HOLDER: PEIKKO GROUP, INC.

ESR-2036 Reissued May 1, 2013 This report is subject to renewal June 1, 2015.

Originally Issued: 11/24/2010 Revised: 01/20/2017 Valid Through: 11/30/ Design

ESR-2604* Reissued January 1, 2011 This report is subject to renewal in two years.

For Anchors, Frame Ties, Steel Piers, & LLBS Support Systems

ESR ICC Evaluation Service, Inc. Issued May 1, 2008 This report is subject to re-examination in one year.

SECTION COLD-FORMED METAL TRUSSES

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: DEWALT 701 EAST JOPPA ROAD TOWSON, MARYLAND EVALUATION SUBJECT:

DIVISION: WOOD, PLASTICS, AND COMPOSITES SECTION: WOOD, PLASTIC, AND COMPOSITE FASTENINGS REPORT HOLDER:

DIVISION: THERMAL AND MOISTURE PROTECTION SECTION: ROOFING AND SIDING PANELS REPORT HOLDER: KINGSPAN INSULATED PANELS, INC.

VOLUNTARY - EARTHQUAKE HAZARD REDUCTION IN EXISTING HILLSIDE BUILDINGS (Division 94 Added by Ord. No. 171,258, Eff. 8/30/96.)

REPORT HOLDER: UNITED DURALUME PRODUCTS, INC. EVALUATION SUBJECT: DURACOOL COMPOSITE STRUCTURAL INSULATED PANELS

DIVISION: CONCRETE SECTION: CONCRETE ACCESSORIES REPORT HOLDER: NELSON STUD WELDING, INC WEST RIDGE ROAD ELYRIA, OHIO 44036

WALL MOUNTED ARTICULATING JIB CRANE

ESR-2269 Reissued November 1, 2008 This report is subject to re-examination in one year.

REPORT HOLDER: ispan SYSTEMS LP 70 BRENTWOOD DRIVE PRINCETON, ONTARIO N0J 1V0 CANADA EVALUATION SUBJECT:

DIVISION: METALS SECTION: STEEL DECKING SECTION: STEEL FLOOR DECKING SECTION: STEEL ROOF DECKING REPORT HOLDER:

DIVISION: MASONRY SECTION: MASONRY ANCHORS REPORT HOLDER: HILTI, INC. EVALUATION SUBJECT: KWIK BOLT TZ MASONRY ANCHORS

REPORT HOLDER: HILTI, INC DALLAS PARKWAY, SUITE 1000 PLANO, TEXAS EVALUATION SUBJECT: HILTI LOW-VELOCITY POWER-ACTUATED FASTENERS

Transcription:

ICBO Evaluation Service, Inc. 5360 WORKMAN MILL ROAD WHITTIER, CALIFORNIA 90601-2299 A subsidiary corporation of the International Conference of Building Officials EVALUATION REPORT Copyright 2001 ICBO Evaluation Service, Inc. Filing Category: DESIGN Steel (038) Reissued April 1, 2001 DIXIE ANCHORING SYSTEMS ALUMA-FORM/DIXIE 3625 OLD GETWELL ROAD MEMPHIS, TENNESSEE 38118 1.0 SUBJECT Dixie Anchoring Systems. 2.0 DESCRIPTION 2.1 General: The Dixie Anchoring Systems are used to underpin foundations of existing structures, to form deep foundations for new structures, to retrofit or remediate deficient foundations of existing structures, and to provide bearing for new foundations. The systems consist of foundation attachments (brackets) and helical steel piers. The foundation attachments are used to connect the foundation of the structure to the installed helical steel pier. 2.2 System Components: 2.2.1 Helical Steel Piers: The steel piers consist of one or more helical-shaped circular steel plates welded to a central steel hub. After fabrication, the piers have a Class B1, hotdipped, galvanized coating, complying with ASTM A 153, as applied. The depth of the helical piers in the soil is typically extended by adding one or more steel hub extension shafts mechanically coupled together to form one long, continuous pier. Extensions can be with or without attached helical-shaped steel plates. Each helical steel plate is 3 / 8 inch (10 mm) or 1 / 2 inch (13 mm) thick and has an outer diameter ranging from 6 to 15 inches (152 to 381 mm), and an inner annulus either 1 1 / 4, 1 1 / 2 or 1 3 / 4 inches (31.7, 38 or 44.5 mm) square. Each plate is formed with all radial sections normal to the central longitudinal axis, ± 3 degrees. The helix pitch is 3 inches (76 mm). The central steel hub of lead sections and extension sections is round cornered square (RCS), solid steel bars. RCS bars are either 1 1 / 4, 1 1 / 2 or 1 3 / 4 inches (31.7, 38 or 44.5 mm) square. Each lead section of a helical steel pier has provisions at the top for a connection to an extension, and has an earth-penetrating pilot at the bottom. Each extension has provisions for a coupler at one end and a connection at the other. The coupler is an integrally forged socket that slips over an RCS hub of the same size. Each socket has a transverse hole so that lead sections and extensions can be connected with a bolt and nut. For all helical pier leads and some extension shafts, helical plates are welded to their respective hubs. Nominal spacing between helical plates is not less than 2.36 times the diameter of the lower helix. Figure 1 illustrates the helical piers and extension shafts. 2.2.2 Foundation Attachments (Brackets): The foundation repair attachments (brackets), Catalog No. N-6401-0046 (Standard Bracket) and N-6401-0049 (Light Duty Bracket), are used to address foundation settlement. The bracket designs conform to the FAsteel ULTRA (patent pending) lifting bracket specifications. The brackets consist of 1 / 2 -inch-thick (12.7 mm) steel support angles welded to a 1 / 2 -inch-thick (12.7 mm) steel support body. After assembly, the attachments are coated with a Class B1, hot-dipped, galvanized coating, complying with ASTM A 153. Figure 2 illustrates the foundation attachments. 2.3 Material Specifications: 2.3.1 Helical Plates and Foundation Attachments (Brackets): Hot-wrought carbon steel for the helical plates conforms to ASTM A 36, with a minimum yield strength of 36,000 psi (248 MPa) and a minimum tensile strength of 58,000 psi (400 MPa). 2.3.2 Pier Hubs (Lead Sections and Extensions): The 1 1 / 4 -, 1 1 / 2 - and 1 3 / 4 -inch (31.7, 38, and 44.5 mm) square RCS hubs are formed from hot-wrought carbon steel conforming to ASTM A 576, Grade C-1045, having minimum yield and tensile strengths of 45 and 82 ksi (310 and 565 MPa), respectively. The hubs are also available in steel conforming to ASTM A 576, Grade 1530M, having minimum yield and tensile strengths of 60 ksi and 110 ksi (414 MPa and 758 MPa), respectively. 2.3.3 Bolts: Coupling bolts are 5 / 8 inch (15.9 mm), 3 / 4 inch (19.1 mm) or 7 / 8 inch (22 mm) in diameter and shall comply with ASTM A 325 Type 1, and shall have a Class C hot-dipped zinc coating that complies with ASTM A 153. The corresponding nut shall conform to either ASTM A 194 Grade 2H or ASTM A 563 Grade DH. Nuts shall have a Class C hotdipped zinc coating that complies with ASTM A 153. 2.4 Design: 2.4.1 General: Structural calculations must be submitted to the building official for each project, and must be based on accepted engineering principles. The design of the steel components must be in accordance with the Allowable Stress Design (ASD) Specification in Chapter 22, Division III, of the code. The ASD design strengths of the steel components are described in Tables 1, 2 and 3. The overall capacity of the Dixie Anchoring System depends upon the analysis of the interaction of the helical plates and the soil, and may be less than the ASD design strengths noted in this report. Combined flexural and compressive stresses, and column buckling of the piers due to compression loads, must be included in the analysis. Construction in Seismic Zones 3 and 4 requires com- Evaluation reports of ICBO Evaluation Service, Inc., are issued solely to provide information to Class A members of ICBO, utilizing the code upon which the report is based. Evaluation reports are not to be construed as representing aesthetics or any other attributes not specifically addressed nor as an endorsement or recommendation for use of the subject report. This report is based upon independent tests or other technical data submitted by the applicant. The ICBO Evaluation Service, Inc., technical staff has reviewed the test results and/or other data, but does not possess test facilities to make an independent verification. There is no warranty by ICBO Evaluation Service, Inc., express or implied, as to any Finding or other matter in the report or as to any product covered by the report. This disclaimer includes, but is not limited to, merchantability. Page 1 of 5

Page 2 of 5 pliance with Section 1809.5.1 of the code. A soil investigation report is necessary and must include the following: 1. Soil properties, including those affecting design. 2. Allowable soil bearing pressure. 3. Suitability for use in seismically active areas. 4. Information on ground-water table, frost depth and corrosion. 2.4.2 Connection to Building Structure: Downward-acting ASD design strength is 60,000 pounds (267 kn) for the FAsteel ULTRA Standard foundation bracket or 15,000 pounds (134 kn) for the FAsteel ULTRA Light Duty bracket. The concrete foundation and slab must be designed and justified to the satisfaction of the building official for concentrated loads due to the foundation and slab repair brackets. Bearing areas on the attachment seat angle not exceeding 100 square inches (2540 mm 2 ) shall be used to calculate the concrete bearing stress at the seat of the FAsteel ULTRA foundation brackets. Bolted connections shall be designed to resist applicable loads in accordance with the code or appropriate evaluation report. In addition, the effects of reduced lateral sliding resistance due to uplift from wind or seismic loads shall be considered for each project. 2.5 Installation: 2.5.1 General: The helical pier foundation system is installed by Aluma-Form/Dixie certified installers, trained to install the Dixie Anchoring System. 2.5.1.1 Helical Steel Piers: The helical piers are installed using rotary motors having forward and reverse capabilities. The torque rating (torsional force) for each of the included three helical pier shaft sizes are 3.4 kip-feet (4.61 kn-m) for 1 1 / 4 -inch (31.8 mm) RCS shafts, 6.0 kip-feet (13.56 kn-m) for 1 1 / 2 -inch (38 mm) RCS shafts and 10.0 kip-feet (13.56 kn-m) for 1 3 / 4 -inch (45 mm) RCS shafts. The piers must be positioned and angled as specified in the approved plans. Helical piers attached to structures are installed either vertically plumb or at a slight inward slope projecting under the foundations. The helical piers must be installed in a continuous manner, with the rate of pier rotation in the range of 5 to 20 revolutions per minute. Extensions are selected based on the number and length, installation torque and site conditions as specified in the approved plans and are connected to the helical pier with the coupling bolts. Coupling bolts must be tightened firmly with a wrench. The piers are installed to the minimum depth shown on plans, but with the top helix not less than 5 feet (1525 mm) below the bottom of the foundation. 2.5.1.2 FAsteel ULTRA Foundation Attachments: Piering bracket attachments are installed by qualified and trained helical pier subcontracting dealers/installers as specified in the approved plans. The foundation slab must be excavated to create L shaped cavities with nominal 30 inches (762 mm) per side square openings to a depth of at least 18 inches (457 mm) below the foundation bottom surface. The exposed foundation surfaces must be prepared and smoothly dressed to receive the piering attachment ( lifting bracket ) without obstruction on the bearing or facing surfaces. The attachment must be pinned firmly to the foundation by driven or threaded fasteners. This connection may occur during or after pier installation. The helical pier (anchor) and shaft extensions must be driven into soil as set forth in Section 2.5.1.1 of this report. Upon obtaining satisfactory installation, the excess shaft extension above the foundation may be cut, normally about 8 to 10 inches (203 to 254 mm) above the footing (or turn down) base. Threaded form rods are placed through the locking plate, then the subassembly is positioned in place on top of the insert. Nuts are placed on each threaded rod and hand-tightened against the locking plate. A hydraulic/ pneumatic jack is positioned with its actuator bearing against this locking plate. The jack is then actuated to transfer the structural load from soil to pier(s). The foundation and/or structure must be monitored for elevation change, using an optical or electronic level. The jack is stopped when the foundation or structure baseline reaches predetermined height as measured by an optical or electronic level. The nuts are immediately tightened by torque wrench or equivalent device on threaded form rods to 75 foot-pounds (102 N-m). 2.6 Special Inspection: Special inspection in accordance with Section 1701 of the code is required for installation of the helical piers and foundation lifting brackets. Inspection must include the following: 1. Verification of catalog numbers. 2. Types and configurations of helical pier lead sections, extensions, brackets, bolt type and torque. 3. Installation procedure and anticipated piering depth. 4. Required target installation torque of piers. 5. Inclination and position of helical pier, hub of pier extension in full contact with bracket, full-surface contact of foundation brackets with concrete, tightness of all bolts, and evidence that anchoring system and FAsteel UL- TRA bracket are installed by an approved Aluma-Form / Dixie authorized foundation stabilization or remediation contractor. 2.7 Identification: Helical piers have D stamped on the hub. The helical piers are also identified by a tag or label bearing the name and address of Aluma-Form/Dixie, the catalog number, the product description, the evaluation report number (ICBO ES ), and the name of the quality control agency (SGS U.S. Testing Company, Inc.). The FAsteel ULTRA foundation brackets are identified by labels bearing the catalog number, the product description, the name and address of Aluma-Form/Dixie, the evaluation report number (ICBO ES ), and the name of the quality control agency (SGS U.S. Testing Company, Inc.). 3.0 EVIDENCE SUBMITTED Material specifications, installation instructions, load tests and a quality control manual. 4.0 FINDINGS That the Dixie Anchoring System described in this report complies with the 1997 Uniform Building Code, subject to the following conditions: 4.1 The helical piers and accessories are manufactured, identified and installed in accordance with this report. 4.2 Special inspection is provided in accordance with Section 2.6 of this report. 4.3 Engineering calculations and drawings, in accordance with recognized engineering principles and design parameters, are provided to the building official. 4.4 A soil investigation for each project site must be provided to the building official for approval in accordance with Section 2.5.1 of this report. 4.5 The helical piers and foundation attachments (lifting brackets) are manufactured at the Aluma-Form/ Dixie facility located in Birmingham, Alabama, under a quality control program with inspections by SGS U.S. Testing Company, Inc. This report is subject to re-examination in two years.

Page 3 of 5 TABLE 1 FOUNDATION ANCHOR MECHANICAL STRENGTH RATINGS: STANDARD, SINGLE HELIX, AND MULTI-HELIX EXTENSIONS 1 HELIX DIAMETER 2 ALLOWABLE CATALOG NUMBER SHAFT LENGTH SHAFT WIDTH 1 st 2 nd HELIX THICKNESS 2 AXIAL LOAD (pounds) 3 N-6401-0016 42 1.25 NA NA NA 34,000 N-6401-0017 60 1.25 NA NA NA 34,000 N-6401-0018 84 1.25 NA NA NA 34,000 N-6401-0019 120 1.25 NA NA NA 34,000 N-6401-0004 42 1.50 NA NA NA 56,250 N-6401-0005 60 1.50 NA NA NA 56,250 N-6401-0006 84 1.50 NA NA NA 56,250 N-6401-0007 120 1.50 NA NA NA 56,250 N-6401-0024 60 1.50 10 NA 0.375 26,900 N-6401-0025 60 1.50 12 NA 0.375 26,900 N-6401-0026 84 1.50 14 NA 0.375 26,900 N-6401-0008 42 1.75 NA NA NA 76,560 N-6401-0009 60 1.75 NA NA NA 76,560 N-6401-0010 84 1.75 NA NA NA 76,560 N-6401-0011 120 1.75 NA NA NA 76,560 N-6401-0020 60 1.75 12 NA 0.375 30,650 N-6401-0021 60 1.75 14 NA 0.375 30,650 N-6401-0027 84 1.75 14 14 0.375 61,300 For SI: 1 inch = 25.4 mm, 1 pound = 0.00448 kn. 2 NA = Not available. 3 Loads apply to anchor or extension capacity only. System capacity may be limited by other factors, such as soil interaction capacity, bracket capacity, or foundation capacity. The allowable axial load reflects the lesser of tension or compression capacity. TABLE 2 FOUNDATION ANCHOR MECHANICAL STRENGTH RATINGS: SINGLE HELIX ANCHORS 1 CATALOG NUMBER SHAFT LENGTH SHAFT WIDTH HELIX DIAMETER HELIX THICKNESS ALLOWABLE AXIAL LOAD (pounds) 2 N-6202-0001 9 1 / 2 1.25 6 0.375 20,167 N-6202-0002 9 1 / 2 1.25 8 0.375 20,167 N-6202-0003 9 1 / 2 1.25 10 0.375 17,500 N-6202-0004 9 1 / 2 1.25 12 0.375 17,500 N-6202-0005 9 1 / 2 1.25 14 0.375 17,500 N-6202-0006 84 1.25 8 0.375 20,167 N-6202-0007 84 1.25 10 0.375 17,500 N-6202-0008 84 1.25 12 0.375 17,500 N-6202-0009 84 1.25 14 0.375 17,500 N-6202-0010 84 1.25 15 0.375 17,500 N-6203-0018 9 1 / 2 1.50 6 0.375 26,900 N-6203-0019 9 1 / 2 1.50 8 0.375 26,900 N-6203-0020 9 1 / 2 1.50 10 0.375 26,900 N-6203-0021 9 1 / 2 1.50 12 0.375 26,900 N-6203-0022 9 1 / 2 1.50 14 0.375 26,900 N-6203-0001 60 1.50 8 0.375 26,900 N-6203-0002 60 1.50 10 0.375 26,900 N-6203-0003 60 1.50 12 0.375 26,900 N-6203-0004 60 1.50 14 0.375 26,900 N-6203-0009 84 1.50 8 0.375 26,900 N-6203-0010 84 1.50 10 0.375 26,900 N-6203-0012 84 1.50 14 0.375 26,900 N-6203-0032 60 1.50 8 0.500 51,110 N-6203-0033 60 1.50 10 0.500 51,110 N-6203-0013 60 1.50 12 0.500 51,110 N-6203-0014 60 1.50 14 0.500 51,110 N-6203-0007 84 1.50 8 0.500 51,110 N-6203-0008 84 1.50 10 0.500 51,110 N-6203-0011 84 1.50 12 0.500 51,110 N-6203-0034 84 1.50 14 0.500 51,110 For SI: 1 inch = 25.4 mm, 1 kip = 4.448 kn. 2 Loads apply to anchor or extension capacity only. System capacity may be limited by other factors such as soil interaction capacity, bracket capacity, or foundation capacity. The allowable axial load reflects the lesser of the tension or compression capacity.

Page 4 of 5 TABLE 3 FOUNDATION ANCHOR MECHANICAL STRENGTH RATINGS: DOUBLE HELIX, TRIPLE HELIX AND QUADRUPLE HELIX ANCHORS 1 SHAFT LENGTH HELIX THICKNESS ALLOWABLE AXIAL LOAD (pounds) 3 SHAFT WIDTH HELIX DIAMETER 2 CATALOG NUMBER Double Helix Anchors N-6202-0011 84 1.25 8 10 NA NA 0.375 34,000 N-6203-0005 60 1.50 6 6 NA NA 0.375 53,800 N-6203-0006 60 1.50 6 8 NA NA 0.375 53,800 N-6203-0025 60 1.50 8 10 NA NA 0.375 53,800 N-6203-0026 60 1.50 10 12 NA NA 0.375 53,800 N-6203-0027 84 1.50 6 8 NA NA 0.375 53,800 N-6203-0028 84 1.50 8 10 NA NA 0.375 53,800 N-6203-0029 84 1.50 10 12 NA NA 0.375 53,800 N-6203-0017 120 1.50 8 10 NA NA 0.375 53,800 N-6203-0023 60 1.50 8 10 NA NA 0.500 56,250 N-6203-0024 60 1.50 10 12 NA NA 0.500 56,250 N-6206-0002 60 1.75 8 10 NA NA 0.375 61,300 N-6206-0003 60 1.75 10 12 NA NA 0.375 61,300 Triple Helix Anchors N-6202-0012 84 1.25 8 10 12 NA 0.375 34,000 N-6203-0030 84 1.50 8 10 12 NA 0.375 56,250 N-6203-0031 84 1.50 10 12 14 NA 0.375 56,250 N-6206-0004 84 1.75 8 10 12 NA 0.375 76,560 N-6206-0005 84 1.75 10 12 14 NA 0.375 76,560 Quadruple Helix Anchors N-6203-0015 120 1.50 8 10 12 14 0.500 56,250 N-6203-0016 120 1.50 10 12 14 14 0.500 56,250 N-6206-0006 120 1.75 8 10 12 14 0.375 76,560 N-6206-0007 120 1.75 10 12 14 14 0.375 76,560 For SI: 1 inch = 25.4 mm, 1 kip = 4.448 kn. 2 NA = Not available. 3 Loads apply to anchor or extension capacity only. System capacity may be limited by other factors such as soil interaction capacity, bracket capacity, or foundation capacity. The allowable axial load reflects the lesser of the tension or compression capacity.

Page 5 of 5 FIGURE 1 HELICAL PIERS AND EXTENSION SHAFT FIGURE 2 FOUNDATION ATTACHMENTS ( LIFTING BRACKETS )