CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers

Similar documents
CENTRIA MetalWrap Insulated-Composite Backup Panel System

SECTION COMPOSITE WALL PANELS PART 1 GENERAL 1.01 SECTION INCLUDES

CENTRIA FORMABOND II Metal Composite Wall System

CENTRIA Intercept Entyre Preformed Metal Modular Panel Wall System

CENTRIA FORMABOND. Aluminum Composite Wall System

CENTRIA Concept Series Metal Wall Panels ZINC

SECTION INSULATED CORE METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

CENTRIA EcoScreen Perforated Screen Wall Panels

CENTRIA Versawall Factory Foamed Metal Wall Panel System

SECTION STAINLESS STEEL WALL PANELS

SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

A. Pre-Installation Conference: Conduct conference at [project site] <insert location>.

Centria Conversion SECTION METAL WALL PANELS AMERICAN ARCHITECTURAL MANUFACTURERS ASSOCIATION (AAMA)

Corium Brick Rainscreen System Specifications

SECTION METAL FRAMED SKYLIGHT. A. Engineering, preparation of fabrication drawings and structural calculations for the entire skylight system.

SECTION TERRA COTTA CLAY TILE RAINSCREEN SYSTEM

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS

PROJECT LOCATION SECTION COPPER METAL PLATE WALL PANELS

PART 1 / GENERAL SECTION ALUMINUM PLATE PANEL SYSTEM. ALPLY Insulated Panels. Alply TECH WALL Aluminum Plate System 2002

CENTRIA Exposed Fastener Series Metal Wall Panels

SECTION COMPOSITE METAL WALL PANEL SYSTEM (Accu-Trac Low Profile DS)

CENTRIA Formawall Graphix Series Insulated Core Metal Wall Panel System

Alply CLASSIC WALL Architectural Insulated Panel Wall System

SECTION FLUID-APPLIED MEMBRANE AIR BARRIERS, VAPOR PERMEABLE

SECTION METAL ROOF PANELS. A. Vertical-rib, seamed joint, standing seam metal roof panels, with related metal trim and accessories.

CENTRIA Concept Series TM Metal Wall Panels

SECTION EXTERIOR SOLID PHENOLIC RAINSCREEN PANELS

SECTION COPPER WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

SECTION ALUMINUM-FRAMED HIGH PERFORMANCE THERMAL ENTRANCE DOORS

METL-SPAN HPCI Barrier Insulated Metal Wall Panels

North Hanover Township School District North Hanover Township, New Jersey

SECTION METAL WALL PANEL SYSTEM

CENTRIA Formawall Dimension Series Insulated Core Metal Wall Panel System

SECTION PORCELAIN TILE WALL SYSTEM. (Porcelanosa Venis Urbatek)

SECTION ALUMINUM STORM WINDOWS

Page 1 of 5

K6746X Florida Product Approval No.: FL7708.2, UL Classified: R25376

Architectural Wall Products Guide Specifications

Metl-Span FW-120 Formed Metal Wall Panels

Metl-Span ShadowRib Formed Metal Wall Panels

SECTION INSULATED CORE METAL WALL PANELS 09/09

Guideline Specifications

Guide Specifications ADP Series SECTION SHEET METAL ROOFING

A. Omega-Lite aluminum-faced composite panels, air and vapor barrier, attachments and sealants.

BEARING METAL STUD FRAMING

Tender No Section St. James - Assiniboia Centennial Pool Fitness Facility Addition Page 1

Architectural Roof and Wall Products Guide Specifications

A. Section includes conventionally glazed aluminum curtain walls installed as stick assemblies.

SECTION ALUMINUM STORM WINDOWS

Architectural Roof Products Guide Specifications

SECTION METAL WALL PANELS

Cardinal Commercial Products ALUMINUM STOREFRONT SYSTEM SERIES CF450 GUIDE SPECIFICATIONS SECTION ALUMINUM ENTRANCES AND STOREFRONT SYSTEMS

SECTION ALUMINUM COMPOSITE MATERIAL WALL PANELS. A. Section includes aluminum composite material wall panels.

Architectural Roof Products Guide Specifications


Guide Specification for the OSI QUAD Window and Door Flashing System

SECTION METAL WALL PANELS

SPECIFICATIONS FOR. CEI Composite Materials, LLC Featuring R4000 Rear Back Ventilated Rainscreen System. Section Aluminum Composite Panels

SECTION METAL ROOF PANEL, STANDING SEAM - SRS3

FL200 13/4 x41/2 GUIDE SPECIFICATION. Non-Thermal Storefront

Ice Rink Renovation & New Clubhouse

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

Student Services & Classroom Addition

SECTION ALUMINUM WINDOWS

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 08 - OPENINGS. A. This Section includes fixed and operable aluminum-framed windows.

LOG COLLEGE MIDDLE SCHOOL

Wall Louvers (10200)

Specifiers: Click on the icon in the WORD toolbar to reveal detailed instructions

SECTION mm METAL COMPOSITE MATERIAL (MCM) RAINSCREEN SYSTEM SPECIFICATION

SECTION EXTERIOR GRILLS AND SCREENS

Omniplate Barrier Wall System

SECTION METAL WALL PANELS

[Project Name] Section [ ]

Metl-Span ThermalSafe Insulated Metal Wall and Ceiling Panels

Signature Series 5 Lap SECTION ALUMINUM WINDOWS

RAMAPO COLLEGE OF NEW JERSEY PHASE II HOUSING REHABILITATION C 2012

METAL COMPOSITE MATERIAL WALL PANELS

Series B450 Guide Specification

SECTION FABRICATED WALL PANEL ASSEMBLIES. A. American Institute of Steel Construction (A.I.S.C.) "Manual of Steel Construction.

SPECIFICATION SECTION PART 1 GENERAL

EMBRY RIDDLE PRESCOTT SECTION METAL COMPOSITE MATERIAL WALL PANELS

Trapezoidal-rib, snap joint, standing seam metal roof panels, with related metal trim and accessories.

SECTION STEEL WINDOWS UL Labeled Fire-Rated Horizontal Slider (900) Use Tools / Options / View / Hidden Text to view hidden notes and edit.

SECTION METAL ROOF PANELS

Architectural Roof and Wall Products Guide Specifications

All Metals Fabrication AMF FUSION DRILLFREE ALUMINUM COMPOSITE METAL (ACM) WALL PANEL SPECIFICATION

COLLEGE OF STATEN ISLAND

SECTION ALUMINUM WINDOWS

SECTION ALUMINUM-FRAMED ENTRANCES AND STOREFRONTS PART 1 - GENERAL 1.1 SUMMARY. A. Section Includes:

B. Engineering design and performance requirements for terracotta rainscreen assemblies.

C. Engineering design and performance requirements for terracotta rainscreen assemblies.

SoCal Dynamic Dome Skylight SECTION UNIT SKYLIGHTS

SECTION / METAL FRAMED SKYLIGHTS

SECTION BLAST RESISTANT WINDOWS

SECTION ALUMINUM COMPOSITE WALL PANELS. ***This section has been updated to IBC. Verify for specific project conditions.***

B. Engineering design and performance requirements for terracotta rainscreen assemblies.

SECTION DETAILS (MECHANICALLY ASSEMBLY)

TRUMAN STATE UNIVERSITY GREENWOOD SCHOOL WINDOW REPLACEMENT

Transcription:

CENTRIA MetalWrap Insulated-Composite Backup Panel System with Integrated Windows and Louvers CENTRIA MetalWrap Insulated Composite Backup Panel System is designed to be used with CENTRIA Formavue FV-600 windows to create a complete backup wall solution for metal wall panel, brick, or terra cotta rainscreens. The unique composite design of MetalWrap provides an air barrier, moisture barrier, and thermal insulation with total wall values up to R-21 in a single, easy-toinstall component. MetalWrap eliminates the need for separate batt or board insulation, sheathing, air barriers, vapor retarders, and building wraps, while providing greater thermal efficiency and moisture control. MetalWrap is designed for use with vertical or horizontal exterior cladding installations, including Profile Products and FormaBond. MetalWrap was developed using ATMP - CENTRIA's Advanced Thermal and Moisture Protection building envelope science; it maximizes a metal wall system's ability to effectively control moisture without sacrificing thermal efficiency. Metal panel wall systems utilizing MetalWrap with steel stud construction and interior gypsum board finish are available with overall wall thermal resistance of R-14 (for 2-inch thick MetalWrap) and R-21 (for 3-inch thick MetalWrap). Formavue FV-600X & FV-600A windows are designed to integrate with the MetalWrap assembly and with CENTRIA metal wall panels to provide a single-source solution to building enclosure air, vapor, and moisture control. Consult your local CENTRIA architectural representative for design assistance. Contact CENTRIA, Pittsburgh, PA, (800)759-7474, Email: info@centria.com, www.centria.com for a list of local offices. CENTRIA is a world leader in the manufacture of metal building products and systems for nonresidential walls and roofs. CENTRIA is also a world-class coil coater, providing a wide range of coated products for customers in numerous industries. CENTRIA products appear in the following MasterFormat sections: Section 07 41 13 Metal Roof Panels (SRS3) Section 07 41 16 Insulated Core Metal Roof Panels (Versapanel) Section 07 42 13 Metal Wall Panels (Cascade Metal Panel System, Intercept V-Trac, Intercept Entyre, Paradigm EXP, Concept Series, IW Series, Exposed Fastener Panels) Section 07 42 16 Insulated-Core Metal Wall Panels (Formawall Dimension Series, Formawall Graphix Series, Versawall, Versapanel, Foamwall, Versashield MW) Section 07 42 17 Insulated Composite Backup Panel (MetalWrap) Section 07 42 43 Composite Wall Panels (FormaBond) Specifier: This document is organized according to CSI MasterFormat. Edit section number and title as appropriate to the Project. Bold items require specifier selection. Convert bold to plain text and delete notes before publishing. MetalWrap and Formavue are trademarks of CENTRIA. ATMP is a registered trademark of CENTRIA. MetalWrap + Formavue Page 1 of 14

MasterFormat is a trademark of the Construction Specifications Institute. This document is Copyright 2014 CENTRIA. MetalWrap + Formavue Page 2 of 14

SECTION 07 42 17 INSULATED-COMPOSITE BACKUP PANEL SYSTEM WITH INTEGRATED WINDOWS AND LOUVERS PART 1 - GENERAL 1.1 SECTION INCLUDES A. Metal wall backup panel system consisting of foamed-insulation-core metal wall panels and accessories, with integrated windows[ and fixed louvers]. 1.2 RELATED REQUIREMENTS Specifier: Edit list below to correspond to Project. A. Division 04 Section ["Unit Masonry"] ["Brick Masonry"] for brick veneer applied over metal wall backup panels. B. Division 05 Section "Cold-Formed Metal Framing" for support framing for metal wall backup panels. C. Division 07 Section "Air Barriers" for transition components to air barrier at perimeter of metal wall backup panels. D. Division 07 Section "Metal Wall Panels" for exterior wall rainscreen panels applied to metal wall backup panels. E. Division 07 Section "Sheet Metal Flashing and Trim" for metal flashing components at openings and perimeter. F. Division 13 Section "Metal Building Systems" for support framing for metal wall backup panels. 1.3 REFERENCES A. Reference Standard Editions: Comply with requirements of specified standards edition cited in applicable building code, or if not cited in code, with requirements of edition current at time of issuing of specifications Specifier: If retaining the optional list of reference standards below, edit list to correspond to Project. B. American Architectural Manufacturer's Association (AAMA): www.aamanet.org: 1. AAMA 809.2 - Voluntary Specification Non-Drying Sealants 2. AAMA 1503 - Voluntary Test Method for Thermal Transmittance and Condensation Resistance 3. AAMA 2605 - Voluntary Specification, Performance Requirements and Test Procedures for Superior Performing Organic Coatings on Aluminum Extrusions and Panels. C. American Society of Civil Engineers (ASCE): www.asce.org/codes-standards: 1. ASCE 7 - Minimum Design Loads for Buildings and Other Structures MetalWrap + Formavue Page 3 of 14

D. ASTM International (ASTM): www.astm.org: 1. ASTM A 653/A 653M - Standard Specification for Steel Sheet, Zinc-Coated (Galvanized) or Zinc-Iron Alloy-Coated (Galvannealed) by the Hot-Dip Process 2. ASTM A 755 - Standard Specification for Steel Sheet, Metallic Coated by the Hot-Dip Process and Prepainted by the Coil-Coating Process for Exterior Exposed Building Products 3. ASTM A 792/A 792M - Standard Specification for Steel Sheet, 55% Aluminum-Zinc Alloy- Coated by the Hot-Dip Process 4. ASTM B 221 - Standard Specification for Aluminum and Aluminum-Alloy Extruded Bars, Rods, Wires, Profiles and Tubes 5. ASTM C 920 - Standard Specification for Elastomeric Joint Sealants 6. ASTM C 1363 - Test Method for Thermal Performance of Building Materials and Envelope Assemblies by Means of a Hot Box Apparatus 7. ASTM D 1929 - Test Method for Determining Ignition Temperature of Plastics 8. ASTM E 72 - Test Methods of Conducting Strength Tests of Panels for Building Construction 9. ASTM E 84 - Test Methods for Surface Burning Characteristics of Building Materials 10. ASTM E 283 - Test Method for Determining the Rate of Air Leakage Through Exterior Windows, Curtain Walls, and Doors under Specified Pressure Differences across the Specimen 11. ASTM E 331 - Test Method for Water Penetration of Exterior Windows, Curtain Walls, and Doors by Uniform Static Air Pressure Difference E. FM Global (FM): www.fmglobal.com: Specifier: Retain FM classification in subparagraph below when required for project utilizing CENTRIA MetalWrap panels with 0.019 inch/26 gage (0.48 mm) face and liner. 1. ANSI/FMG 4880 - Class 1 Fire Rating of Insulated Wall or Wall and Roof/Ceiling Panels, Interior Finish Materials or Coatings, and Exterior Wall Systems F. National Fire Protection Association (NFPA): www.nfpa.org: 1. NFPA 285 - Standard Fire Test Method for Evaluation of Fire Propagation Characteristics of Exterior Non-Load-Bearing Wall Assemblies Containing Combustible Components G. Underwriters Laboratories, Inc. (UL): www.ul.com: 1. UL 263 - Fire Tests of Building Construction and Materials 2. UL 723 - Test for Surface Burning Characteristics of Building Materials 1.4 PERFORMANCE REQUIREMENTS A. General: Provide metal wall backup panel system meeting the following performance requirements as determined by a qualified testing agency s application of specified tests on manufacturer s standard assemblies. Specifier: Retain "Recycled Content of Steel Sheet" paragraph when required for general sustainable design requirements of project. B. Recycled Content of Steel Sheet: Postconsumer recycled content plus one-half of pre-consumer recycled content not less than 25 percent. MetalWrap + Formavue Page 4 of 14

C. Wall Panel Structural Performance: Provide metal wall backup panel system fabricated to withstand effects of indicated loads and stresses within limits and under conditions indicated, when tested per ASTM E 72. Specifier: Consult structural engineer and edit below as required by local codes. 1. Wind Load Test: Determine loads based on uniform pressure indicated on the drawings. 2. Deflection Limits Test: Withstand test pressures of 150 percent of inward and outward wind-load design pressures with maximum deflection of 1/120 of the span with no evidence of failure. 3. Seismic Performance Test: Comply with ASCE 7, Minimum Design Loads for Buildings and Other Structures. Sections 11 23, Seismic. D. Wall Panel Air Infiltration Test: Maximum 0.01 cfm/sq. ft. (0.05 L/s * sq. m) per ASTM E 283 at a static-air-pressure difference of 1.57 lb./sq. ft. (75 Pa). E. Wall Panel Water Penetration Test: No uncontrolled water penetration at a static pressure of 15 lb./sq. ft. (720 Pa) per ASTM E 331. F. Wall Panel Thermal Performance Test: Thermal Resistance (R-value) for panels indicated, per ASTM C 1363, corrected to 15 mph (24.1 k/h) outside and still air inside, as-installed condition including fastening and joints. Specifier: Metal cladding on CENTRIA MetalWrap panels meets requirements for thermal protection of foam plastics in IBC Chapter 26. G. Fire-Test-Response Characteristics: Provide metal wall backup panel system with the following fire-test-response characteristics determined by the indicated test standard as applied by UL or other testing and inspection agency acceptable to authorities having jurisdiction. 1. Surface Burning Characteristics: Not greater than the following, per ASTM E 84 or UL 723, for foam core and interior surface: a. Flame spread index: 25 or less. b. Smoke developed index: 450 or less. Specifier: Retain "Intermediate Scale Multistory Fire Test" Paragraph when required by authorities having jurisdiction. 2. Intermediate Scale Multistory Fire Test: Representative mockup tested per NFPA 285. Specifier: Retain "Fire Performance of Insulated Wall" subparagraph when required by Owner's insurer; retain requirement for 26 ga. panel faces in Part 2. 3. Fire Performance of Insulated Wall: Approved as a Class 1 wall panel per ANSI/FM 4880. 1.5 QUALITY ASSURANCE Specifier: If project procurement procedures allow retaining manufacturer and product name in Part 2, retain paragraph and subparagraphs below to establish project procedures for evaluation of substitution requests. MetalWrap + Formavue Page 5 of 14

A. Manufacturer Qualifications: Manufacturer listed in this Section or approved for Project with minimum 5 years experience in manufacture of similar products in successful use in similar applications. 1. Approval of Comparable Products: Submit the following in accordance with project substitution requirements, within time period allowed for substitution review: a. Product data, including certified independent test data indicating compliance with requirements. b. Samples of each component. c. Sample submittal from similar project. d. Project references: Minimum of 5 installations not less than 5 years old, with owner contact information. e. Sample warranty. 2. Substitutions following award of contract are not allowed except as stipulated in Division 01 General Requirements. 3. Approved manufacturers must meet separate requirements of Submittals Article. B. Installer Qualifications: Experienced Installer with minimum of 5 successful completed projects of similar materials and scope and employing workers trained by manufacturer to install products of this section. Specifier: Retain "Buy American Act Certification" paragraph when required by project; coordinate with requirements in Submittals article. C. Buy American Act Certification: Comply with provisions of the Buy American Act 41 U.S.C 10a 10d. Specifier: Retain paragraph below if scope of composite wall panel installation warrants a mockup. Consider either a free-standing mockup or a mockup consisting of a portion of the final building wall to establish standards of workmanship. Coordinate this requirement with mock-up requirements of related sections. Show extent of mockup on Drawings. A. Mockups: Build mockup in size and location indicated. Show details of composite wall panel system. Demonstrate methods and details of installation. Show details of joints, penetrations, windows, louvers, pipe openings, inside and outside corners, and top and bottom of wall, and attachment of rainscreen cladding. 1. Approval of mockup does not relieve Contractor of responsibility to comply with all requirements of contract documents. 2. Approved mockup may become part of installation if approved by Architect. 1.6 ADMINISTRATIVE REQUIREMENTS A. Coordination: Coordinate the installation of metal wall backup panel system structural support and exterior cladding wall. B. Preinstallation Meeting: Conduct preinstallation meeting at site attended by Owner, Architect, manufacturer's technical representative, and other trade contractors. 1. Coordinate building framing in relation to metal wall backup panels. MetalWrap + Formavue Page 6 of 14

2. Coordinate window, door, and other openings and penetrations of metal wall backup panels. 1.7 ACTION SUBMITTALS A. Product Data: Manufacturer s data sheets for metal wall backup panels and accessories. B. Shop Drawings: Prepared by manufacturer or manufacturer's authorized dealer. Installation drawings for metal wall backup panels, integrated windows, integrated louvers, flashing, accessories, and anchorage systems must indicate completely dimensioned structural frame and erection layouts, openings in the wall, special framing details, and construction details at corners, building intersections and flashing, location and type of mastic and metal filler strips. 1. Indicate coordination dimensions related to structural support system elements provided by others. 2. Include structural data indicating compliance with performance requirements. Specifier: Retain and edit below to comply with Project requirements for sustainable design requirements. 1.8 INFORMATIONAL SUBMITTALS A. Product Test Reports: Indicating compliance of products with requirements, from a qualified independent testing agency. B. Qualification Information: For Installer firm, Installer s field supervisor. Specifier: Retain "Buy American Act Certification" paragraph when required by project; coordinate with requirements in Submittals article. C. Buy American Act certification. 1.9 CLOSEOUT SUBMITTALS A. Maintenance data. 1.10 DELIVERY, STORAGE, AND HANDLING A. Protect metal wall backup panels during shipping, handling, and storage to prevent staining, denting, or other visible damage. Deliver, unload, store, and erect metal wall backup panels and accessory items without misshaping panels or exposing panels to surface damage from weather or construction operations. Protect from exposure to sunlight. 1.11 WARRANTY Specifier: Retain first "Special Manufacturer's Warranty" paragraph below when specifying CENTRIA MetalWrap panels in conjunction with CENTRIA metal wall panels as a combined cladding and backup system. A. Special Manufacturer s Warranty: Refer to Division 07 metal wall panel section for warranty requirements for combined metal wall panel cladding and metal wall backup panel system. MetalWrap + Formavue Page 7 of 14

Specifier: Warranty terms below are available from CENTRIA. Verify that other allowable manufacturers furnish warranty meeting requirements. B. Special Manufacturer s Warranty: On manufacturer s standard form, in which manufacturer agrees to repair or replace metal wall backup panel assemblies that fail in materials and workmanship within [2] years from date of Substantial Completion. PART 2 - PRODUCTS 2.1 SYSTEM DESCRIPTION A. Insulated-Core Metal Wall Backup Panels: Metal wall backup panel assembly consisting of foamed-insulation-core metal-skinned wall panels and accessories, with integrated windows[ and louvers,] attached to metal framing with specified clips, serving as combined thermal, air, and moisture barrier and support for [metal wall panel rainscreen cladding] [brick veneer] [terra cotta veneer] specified in another section. Specifier: If project procurement procedures allow retaining manufacturer and product name, retain paragraph and subparagraphs below and modify as required. 2.2 MANUFACTURERS A. Basis of Design: CENTRIA, MetalWrap with Formavue FV-600 Windows [and integrated louvers]. Provide basis of design products [or comparable products of other manufacturer approved by Architect in accordance with Instructions to Bidders and Division 01 General Requirements]. 1. CENTRIA Architectural Systems; Moon Township PA 15108-2944; (800)759-7474; (412)299-8000; info@centria.com; www.centria.com. B. Single Source: Obtain metal wall backup panels, integrated windows[ and louvers] [, and metal wall backup panels and exterior cladding panels specified in Division 07 Section "Metal Wall Panels" ] through one source from a single approved manufacturer. Specifier: CENTRIA MetalWrap Insulated Composite Backup Panels are available in 12 foot (3658 mm) and 20 foot (6096 mm) lengths, in two widths, in two thicknesses for horizontal applications and two thicknesses for vertical applications. Panels are configured and shipped to accommodate application for backup for vertical or horizontal metal cladding or as masonry veneer backup. 2.3 METAL WALL BACKUP PANELS A. Insulated Composite Backup Panels: Foamed-insulation-core metal-skinned panels with interlocking side joinery and butted end joints. Fabricate in factory with metal facings bonded to foamed-in-place core. Fabricate interior metal face with planking ribs. Form interlocking joinery to accept concealed fasteners for attachment to supports. 1. Basis of Design Product: CENTRIA, MetalWrap Insulated Composite Backup Panel. MetalWrap + Formavue Page 8 of 14

Specifier: Retain one "Panel Faces" paragraph below as required for project. 29-ga panel is typical for horizontal applications; 26-ga panel is required for vertical MetalWrap applications and for horizontal applications where compliance with FM 4880 Class 1 fire rating is required. B. Panel Faces: 0.0142-inch/29-ga. (0.360-mm) thick aluminum-zinc alloy coated steel sheet: ASTM A 792/A 792M, Class AZ50 (Class AZM150) coating designation; structural quality, with smooth surface. C. Panel Faces: 0.019-inch/26-ga. (0.483-mm) thick metallic-coated steel sheet: ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality, with smooth surface. Specifier: First option in "Panel Face Finish" paragraph is standard; second option is available for louver blank-off panels. D. Panel Face Finish: [0.2-mil (0.051-mm) thick primer coat] [0.2-mil (0.051-mm) thick primer coat plus 0.8-mil (0.203-mm) thick black silicon polyester color coat on exterior face and 0.2-mil (0.051-mm) thick primer coat on interior face]. E. Panel Core: Foamed-in-place modified polyisocyanurate, closed-cell, CFC and HCFC free, with minimum density of 2.4 lb./cu. ft. (39 kg/cu. m) and minimum compressive strength of 15 lb./sq. in. (103 kpa). F. Panel Sealant/Vapor Seal: Factory-applied non-curing butyl. G. Horizontal Metal Wall Backup Panel Size and Thermal Resistance: Specifier: Retain one of two options based upon panel width requirements. 1. [36 inches (914 mm)] [32 inches (813 mm)] wide by 3 inches (76 mm) thick; R-21. H. Panel Configuration: Provide metal wall backup panels configured for the following application system: Specifier: Retain one or more of the following backup panel configurations as required for project. System in subparagraph below corresponds to CENTRIA MetalWrap Type 1 System with MR-100 Integral Attachment System utilizing VS-300 subgirt. 1. Horizontal metal wall backup panels with integral pre-punched attachment system configured to serve as attachment points for manufacturer-furnished vertical subgirts to receive horizontal cladding. System in subparagraph below corresponds to CENTRIA MetalWrap Type 2 System with MR-300 Integral Attachment System utilizing VS-300 subgirt. 2. Horizontal metal wall backup panels with integral pre-punched attachment system configured to serve for the direct attachment of vertical cladding, or as attachment points for manufacturer-furnished vertical subgirts to receive horizontal cladding System in subparagraph below corresponds to CENTRIA MetalWrap Type 3 System utilizing Hohmann and Barnard 200 Series Joint Anchors and 200 Series Surface Mount Anchors. 3. Horizontal metal wall backup panel for masonry veneer, with manufacturer-furnished veneer anchors in panel joints and attached at panel midpoints. MetalWrap + Formavue Page 9 of 14

System in subparagraph below corresponds to CENTRIA MetalWrap Type 4 System. Utilize CENTRIA 14 ga. A-42 clip for 2 inch thick panels, and A-43 clip for 3 inch panels. System requires minimum 16 ga. steel stud framing. 4. Horizontal metal wall backup panel with manufacturer-furnished 0.064 inch/14 ga. (1.63 mm) zee clips configured to serve as attachment points for vertical subgirts to receive horizontal cladding. 2.4 METAL WALL BACKUP PANEL ACCESSORIES A. Subgirts: Metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z275) coating designation; structural quality, 0.054-inch (16-gage) (1.37-mm) thick. B. Panel Mounting Clips: Metallic-coated steel sheet, ASTM A 653/A 653M, G90 (Z275) coating designation, of thickness indicated, configured to serve as attachment points for secondary metal framing where indicated, manufacturer-furnished. C. Self-Adhering Sheet Flashing: Minimum 25-mil (0.64-mm) modified bituminous sheet, recommended by panel manufacturer for application. D. Joint Sealants: 1. Concealed: Non-skinning butyl sealant, AAMA 809.2. 2. Exposed: Elastomeric silicone sealant, ASTM C 920, as recommended by panel manufacturer. E. Fasteners: Corrosion-resistant, self-tapping and self-drilling screws, bolts, nuts, and other fasteners as recommended by panel manufacturer for application. 1. Size fasteners to prevent penetration of interior panel facing. 2.5 INTEGRATED WINDOW SYSTEM Specifier: Select one of two integrated window systems below based on project requirements. A. Integrated Window Units: Thermally-broken fixed aluminum window units designed to integrate with insulated composite backup panel and secondary support system without receptor channels. 1. Basis of Design: CENTRIA, Formavue FV-600X Integrated Window System. a. System Depth: [FV600X] 3 inches (76 mm), [FV600A] 6 inches (152 mm). b. Exterior Sightlines: Head, sill, and mullions, 3 inches (76 mm). c. Configuration: [Punched window] [Single lite] [Stacked glass] [Strip windows] [As indicted]. d. Mullions: [Full] [Structural glazed] e. Frame: Weathered joints are shop assembled; Thermally improved 6063-T5 aluminum extrusions; Fully integrated with panel joinery; No receptors, [Inside glazed] [Outside glazed] Specifier: Select exterior and interior window finishes from options below MetalWrap + Formavue Page 10 of 14

2. Finish, Exterior: a. Match metal wall panel finish b. Fluoropolymer, 2-coat, AAMA 2605, color as selected by Architect from manufacturer s full range. c. Fluoropolymer, 2-coat, AAMA 2605, [Custom color matching] [Specifier insert color selection] d. Clear Anodic Finish, Architectural Class 1, AAMA 611. 3. Finish, Interior: a. Match metal wall panel finish b. Fluoropolymer, 2-coat, AAMA 2605, color as selected by Architect from manufacturer s full range. c. Fluoropolymer, 2-coat, AAMA 2605, [Custom color matching] [Specifier insert color selection] d. Clear Anodic Finish, Architectural Class 1, AAMA 611. 4. Glazing: [1/4 inch (6 mm) single-glazed] [1 inch (25.4 mm) insulating glass] [As specified in Division 08 Section Glazing. 2.6 INTEGRATED WALL LOUVER UNITS Specifier: Select 7 inch or 9 inch deep louver units by retaining one of two paragraphs below. A. Storm-Resistant Fixed Drainable Horizontal Integrated Louver, 7 inch (178 mm) Deep: 1. Product: C/S Louvers by Construction Specialties, Inc., Model MW-7315. 2. Material: Heads, sills, jambs and mullions to be one-piece structural aluminum members with integral caulking slot and retaining beads. 3. Description: Louver is designed to collect and drain water to exterior at sill by means of multiple gutters in blades and channels in jambs and mullions. 4. Sill Flashings: 4 inch (101.6 mm) high by full depth, formed from minimum 0.050 inch (1.27 mm) thick aluminum, with welded side panels. 5. AMCA Performance: A 4 by 4 foot (1219 by 1219 mm) unit shall conform to the following: a. Free Area: 8.09 sq. ft. (0.75 sq. m). b. Intake Pressure drop at 900 fpm (274 m/min) free area velocity: 0.33 inches H2O (82 Pa). c. Exhaust pressure drop at 900 fpm (274 m/min) free area velocity: 0.42 in. H2O (104.4 Pa). 6. Wind Driven Rain Performance: Provide AMCA certified unit providing performance not less than that indicated below, based upon 39.37 inch (1.00 m) by 39.37 inch (1.00 m) core area, tested at a rainfall rate of 3.0 inches (75 mm) per hour with wind directed to the face of louver at 29.1 mph (13 m/s). Test data shall indicate water penetration effectiveness rating at each corresponding ventilation rate: a. Core Ventilation Rate (m/s): 0.0 0.5 1.0 1.5 2.0 2.5 3.0 3.4 b. Core Ventilation Rate (ft./min): 0 116 194 293 392 495 592 671 c. Free Area Ventilation Rate (ft./min): 0 232 388 597 785 991 1185 1343 d. Rating effectiveness: A A A A B B C D e. Effectiveness Rating: A: 1 to 0.99; B: 0.989 to 0.95; C: 0.949 to 0.80; D: 0.80 to 0 MetalWrap + Formavue Page 11 of 14

7. Integrated Engineered System: Integrated inactive louver with specified insulated backup panels, with custom mounting channel and braces where required; louver and metal panel system integration shall be accomplished while maintaining specified metal panel system performance. B. Storm-Resistant Fixed Drainable Horizontal Integrated Louver, 9 inch (229 mm) Deep: 1. Product: C/S Louvers by Construction Specialties, Inc., Model MW-9615. 2. Material: Heads, sills, jambs and mullions one-piece 0.081 inch (2.06 mm) aluminum, with fixed blades 0.080 inch (2.03 mm) and 0.050 inch (1.27 mm) thick. 3. Description: Horizontal front blade and a vertical rear blade in a drainable frame. 4. Sill Flashings: 4 inch (101.6 mm) high by full depth, formed from minimum 0.050 inch (1.27 mm) thick aluminum, with welded side panels. 5. AMCA Performance: A 4 by 4 foot (1219 by 1219 mm) unit shall conform to the following: a. Free Area: 9.46 sq. ft. (0.879 sq. m). b. Intake Pressure drop at 900 fpm (274 m/min) free area velocity: 0.25 inches H2O (62.2 Pa). 6. Wind Driven Rain Performance: Provide AMCA certified unit providing performance not less than that indicated below, based upon 39.37 inch (1.00 m) by 39.37 inch (1.00 m) core area, tested at a rainfall rate of 3.0 inches (75 mm) per hour with wind directed to the face of louver at 29.1 mph (13 m/s). Test data shall indicate water penetration effectiveness rating at each corresponding ventilation rate: a. Core Ventilation Rate (m/s): 0.0 0.5 1.0 1.5 2.0 3.0 4.0 5.0 b. Core Ventilation Rate (ft./min): 0 98 197 295 394 591 787 977 c. Free Area Ventilation Rate (ft./min): 0 150 300 450 600 900 1201 1490 d. Rating effectiveness: A A A A A A A A e. Effectiveness Rating: A: 1 to 0.99; B: 0.989 to 0.95; C: 0.949 to 0.80; D: 0.80 to 0 7. Integrated Engineered System: Integrated inactive louver with specified insulated backup panels, with custom mounting channel and braces where required; louver and metal panel system integration shall be accomplished while maintaining specified metal panel system performance. C. Louver Finish: 1. Match metal wall panel finish. 2. Fluoropolymer, 2-coat, AAMA 2605, [color as selected by Architect from manufacturer s full range] [custom color match] [Specifier insert color selection]. 3. Clear Anodic Finish, Architectural Class I, AAMA 611. 2.7 FABRICATION A. Metal Wall Backup Panels: Fabricate metal wall backup panels at the factory, using manufacturer's standard procedures and processes identical to tested units and as necessary to meet performance requirements. 1. Fabricate metal wall backup panels with joints between panels designed to form weathertight seals. MetalWrap + Formavue Page 12 of 14

2. Factory form metal wall backup panels in a continuous process with no glues or adhesives between dissimilar materials. Trim and square edges of sheets with no displacement of face sheets or protrusion of core material. B. Windows and Louvers: Complete fabrication, assembly, finishing and other work in the factory to greatest extent possible. PART 3 - EXECUTION 3.1 EXAMINATION A. Examine building structure with Installer present. Inspect for erection tolerances and other conditions that would adversely affect installation. B. Wall Substrate: Confirm that wall substrate is within tolerances acceptable to metal wall panel system manufacturer. 1. Maximum wall plane deviations acceptable to metal wall backup panel system manufacturer: a. 1/4 inch (6.4 mm) in any 20-foot (6 m) length vertically or horizontally from the framing face plane. b. ½ inch (12.7 mm) from flat substrate on any elevation. c. 1/8 inch (3 mm) within 5 feet (1.54 m) of wall transitions such as corners and soffits. C. Framing: Inspect framing that will support metal wall backup panel system to determine if support components are installed as indicated on approved shop. D. Advise G.C, in writing, of out-of-tolerance work and other deficient conditions prior to proceeding with metal wall panel system installation. E. Correct out of tolerance work and other deficient conditions prior to proceeding with insulated composite backup panel installation. 3.2 METAL WALL BACKUP PANEL SYSTEM INSTALLATION A. General: Install metal wall backup panel system in accordance with approved shop drawings and manufacture's recommendations. B. Installation: Attach backup panels to supports at each panel connection point indicated on approved shop drawings. 1. Install with drain plane of panel facing weather side of installation. 2. Fasten insulated metal wall backup panels to building framing with [continuous integral attachment subgirts] or [special clips and anchors] provided by manufacturer utilizing recommended fasteners. 3. Horizontal Joinery: Working from base to top of metal wall backup panel system installation, engaging upper panel over lower panel to form a weather tight joint oriented to allow gravity drainage. 4. Vertical Joinery: a. Install vertical butt joints tight with no gap, set against continuous supports. MetalWrap + Formavue Page 13 of 14

b. Set panel ends in continuous bead of non-curing butyl sealant as indicated in manufacturer's installation details. c. Seal butt joints between adjacent panels with a continuous strip of self-adhering flashing at bottom row of panels and where additionally recommended by manufacturer or architect. 3.3 INTEGRATED UNIT INSTALLATION A. Install [window units] [and] [louvers] in accordance with manufacturer s recommendations and approved shop drawings in conjunction with metal wall backup panel system. END OF SECTION 1. Anchor to assembly using anchors approved by manufacturer. Assemble components using gaskets, fasteners, sealants and trim supplied or approved by metal wall panel manufacturer. Separate dissimilar metals with bituminous coating. 2. Install [window units] [and] [louvers] to drain condensation, penetrating water, and migrated moisture to the exterior. MetalWrap + Formavue Page 14 of 14