Air Quality Monitoring of Operation Theaters in Government Medical College and Hospital, Aurangabad, India

Similar documents
Microgen and Airocide Technology as a Method for Sterilization in ICU: A Comparative Study

Orthophenylphenol in healthcare environments: a trial related to a new administration method and a review of the literature*

Environmental Surveillance FIDSSA Dr Ben Prinsloo Medical Microbiologist

Evaluation of effectiveness of Sterigen as. an agent for fumigation and surface. disinfection

Seasonal Variation of Airborne Microflora in Dairy Processing Plant

Evaluation of a Novel Non-Sterile Glove Dispensing System Uyen Nguyen

Analytical Service Code

Ultraviolet in-room air disinfection and recirculation greatly reduces viable airborne particle concentrations in the operating room setting.

BIO & PHARMA ANALYTICAL TECHNIQUES

IN THIS SECTION MICROBIOLOGY TESTING EXPERT SOLUTIONS FOR PRODUCT DEVELOPMENT. Bacterial Endotoxin (LAL) Testing

Ultraviolet in-room air disinfection and recirculation greatly reduces viable airborne particle concentrations in the operating room setting.

MICROBIO BIOAEROSOL SAMPLING

MICROBIO BIOAEROSOL SAMPLING

Int.J.Curr.Microbiol.App.Sci (2017) 6(11):

INTERPRETING MICROBIAL MEASUREMENT AND ANALYSIS

Diagnostic Microbiology

Thinking outside the box: First experiences from the research OR in Weiden with a new surgical ventilation system

Tissue Culture Sterilization and Contamination

Selection of Storage Methods for Maintenance of Different Stock Cultures

GUIDE TO INSPECTIONS OF MICROBIOLOGICAL PHARMACEUTICAL QUALITY CONTROL LABORATORIES

Bacterial load was measured using the method described previously (1). The necrotic tissue

Laminar flow in orthopaedic operations - Essential if you can afford it. Peter Hoffman Consultant Clinical Scientist Public Health England

The Cat s Out of the Bag: Microbiological Investigations of Acute Transfusion Reactions.

Reducing Microbial Contamination in Hospital Blankets utilizing MonoFoil Antimicrobial. By James W. Krueger

Terminal Disinfection in Hospitals with Quaternary Ammonium Compounds by Use of a Spray-Fog Technique

A mobile laminar airflow unit to reduce air bacterial contamination at surgical area in a conventionally ventilated operating theatre

Microbiological Methods

Microbiology sheet (6)

Preparing and Gram-staining a bacteriological smear

Health & Public Safety Management

Microorganisms are the agents of contamination, infection. Hence it becomes necessary to remove them from materials and areas.

Reducing Microbial Contamination in Hospital Blankets

Log Reduction & UV Deceptive Advertising

The effect of mechanical ventilation and clothing on airborne microbes and wound sepsis in hospital operating rooms, Part 2

Asepsis. Microorganisms 7/7/2010. Categorization of Microorganisms. Sonia Green, BSN, RN

Comparison of the speed of kill of pathogenic bacteria using ACTICOAT and AQUACEL Ag analysed using Confocal Laser Scanning Microscopy

Hospital Indoor Airborne Microflora in Private and Government Owned Hospitals in Benin City, Nigeria

Microbiological Methods

Microbiology for Oral and Topical Products - The basics Scott Colbourne Business Manager NSW ALS Food & Pharmaceutical

UNDER SECRETARY FOR HEALTH S INFORMATION LETTER MICROBIOLOGICAL ASSESSMENT OF PHARMACEUTICAL CLEANROOMS

Clean Air in the Operating Room

BIO-SAFETY IN MICROBIOLOGIC AND BIOMEDICAL LABORATORIES. Dr. K. P. Narkhede

Microbiological Screening of the Environments of Two Hospitals In Nablus

Characterization of indoor bioaerosols from a hospital ward in a tropical setting

Microbiologic Sampling of the Environment

Microbiological Quality of Drug Products after Penetration of the Container System for Dose Preparation Prior to Patient Administration

Reducing Microbial Contamination in Hospital Blankets

The attached report is the result of a mold and bacterial assessment conducted at th Street, Franklin, Ohio on April 24 and 25, 2008.

Investigation on CA-MRSA isolates for eradication measures:

Impact of a disinfecting technique on microbial contamination of computer keyboards and telephone handsets

Indoor Airborne Microbial Burden of Operating Theatres in a Tertiary Hospital in South-Western Nigeria

CLENDO INDUSTRIAL LABORATORY. CUSTOMER SAMPLE ANALYSIS REPORT Page1 of 8. FDA No CLENDO CONTROL NO. 9081, 9095

FDA s Guidance for Industry

A membrane filter technique for testing disinfectants

Immobilization and Death of Bacteria by Flora Seal Microbial Sealant

Developed and Presented by: Wisconsin Healthcare Engineering Association

Policy # MI_SFLD Department of Microbiology. Page Quality Manual TABLE OF CONTENTS

Tests to Support Sterility Claim. Imtiaz Ahmed

What is Aero microbiology?

This training module covers the following animals housed in vivaria: rodents rabbits birds amphibians reptiles non-human primates other mammals

Microbicidal Properties of a Silver-Containing Hydrofiber Dressing Against a Variety of Burn Wound Pathogens

How to Prevent Central Line- Associated Sepsis in the NICU

PROFICIENCY TESTING PROGRAMS MICROBIOLOGY

Indoor air quality at selected wards at a South African government hospital. *N.J. Malebo 1 and K. Shale 2

PURE CULTURE TECHNIQUES

Principles of Preservation

MLT 116L Clinical Microbiology Lab

STS Directory Accreditation number: STS 0268

Biocontamination control in pharmaceutical production

Preparing and Gram-staining a bacteriological smear

Evaluating Utility Gloves as a Potential Reservoir for Pathogenic Bacteria

Culturing microorganisms may be hazardous

2120 Lab. Week 11. Experiments 13,14,21. Kirby Bauer, TDT, Chemicals

Laboratory Procedures in Clinical Microbiology

State of Kuwait Ministry of Health Infection Control Directorate. The role of infection control In design of health care facilities

55 Industrial Park Road Boothbay, ME USA

HOSPITAL AND OPERATION THEATRE INDOOR AIR QUALITY ASSURANCE OPERATIONAL GUIDELINES

Today s Topics. General Quality Control Best Practices. Practices Antimicrobial Effectiveness Testing(AET) Best Practices Environmental Isolates

USE OF IN-DUCT UVC LAMPS TO INACTIVATE AIRBORNE ENVIRONMENTAL BACTERIA AND FUNGI

Exercise 19. Fungi: Molds and Yeasts F10 Or The Rotten World Around Us

University Medical Microbiology

TRANSPORTATION OF INFECTIOUS SUBSTANCES

Verification of Environmental Cleaning & the Impact on Patient Safety

MICROBIOLOGICAL TOOLS FOR QUALITY ASSURANCE IN HATCHERY: Laboratory Methods

Microbiology Testing: USP requirements for Sterile and Nonsterile Preparations Webinar Q&A

Stay or Go: A Study on Oxygen Tension on the Biofilm Formation of Cystic Fibrosis Bacteria. Honors Project. In fulfillment of the Requirements for

Test record CFU measurement. Test ID Site/Clinic Spijkenisse

MICROBIOLOGY AND INVASIVE FUNGAL INFECTION. Javier Pemán, MD, PhD. Mycology Unit, Hospital Univ. La Fe Valencia (Spain)

ANALYTICAL REPORT: Comparison of the Microbial Recovery Efficacy of QI Medical EnviroTest Paddles versus a Conventional Contact Plate

THE UNIVERSITY OF NEWCASTLE- SCHOOL of BIOMEDICAL SCIENCES

CONTROL OF MICROBIAL GROWTH - DISINFECTANTS AND ANTISEPTICS

Investigation on CA-MRSA isolates for eradication measures:

Testing the Effectiveness of Antiseptics and Disinfectants *

Environmental. National Legionella Conference Sample Taking Workshop. Right Solutions Right Partner

endurocide SPORICIDAL HOSPITAL DISPOSABLE CURTAINS

The University of Ferrara Study At the St. Anne Hospital

Effectiveness Of UVC Lights Irradiation To Improve Energy Saving

Biological Consulting Services of North Florida, Inc.

Environmental Pollution and Animal Health. Dr Abdul-Hadi Abbass Abd

PATTERN AND SENSITIVITY TEST AGAINST BACTERIA IN THE AIR AT OB/GYN OPERATING

Transcription:

International Journal of Current Microbiology and Applied Sciences ISSN: 2319-7706 Volume 5 Number 6 (2016) pp. 42-49 Journal homepage: http://www.ijcmas.com Original Research Article http://dx.doi.org/10.20546/ijcmas.2016.506.005 Air Quality Monitoring of Operation Theaters in Government Medical College and Hospital, Aurangabad, India M.M. Kasdekar, M.M. Duthade*, A.S. Damle, M.N. Khapurkuntikar, J.A. Iravane, J.B. Bhakre and A.A. Gaikwad Department of Microbiology, Government Medical College, Aurangabad, India *Corresponding author A B S T R A C T K eywo rd s Air quality monitoring, Settle plates, Operation theatres (OT). Article Info Accepted: 07 May 2016 Available Online: 10 June 2016 Air quality of any place reflects its hygienic condition, especially in health care centres like hospitals there are higher chances of infectious microorganisms to be present suspended in the environment, air quality monitoring hence plays important role so as to keep check on the environment and take useful measures to improve it. Air quality monitoring of operation theatres is more important as there are higher chances of microorganisms suspended in air to get settled in operation site later resulting into post-operative surgical site infections and consequently increasing morbidity and mortality. This study was aimed to monitor Quality of air in the form of bacterial load in operation theatres by Settle plate method (passive air sampling), to identify the presence of fungi and to see the rate of infection in postoperative patients in respective wards of hospital. 100 settle plates were studied from 6 different Operation Theatres (OT) from Hospital in a period of one year January 2015 to December 2015. Out of 100 settle plates 28 plates were positive showing discrete macroscopic bacterial or fungal colonies. Among 28 positives OT 1 and OT 4 both shows 9 and 8 settle plates of maximum positives respectively.ot3 shows 5, OT 2 shows 4 and CVTS and CVTS Cath lab shows positive for one settle plates each. Organisms isolated were Staphylococcus aureus (57%), Pseudomonas spp (7%), other gram negative organisms and fungal species of Aspergillus niger (7%). Patients who had undergone surgeries in OTs with settle plate positive were followed up for any post-operative surgical site infections. Harbouring of potential pathogens in OTs of hospital can pose a great risk to patients operated in hospital. Introduction Microbial contamination of air/surfaces /articles in OTs is a major cause of surgical site and nosocomial infections (Bhalla et al., 2007). Air bio-load present in the form of aerosols may contain bacteria, viruses, yeasts, moulds and fungal spores. These may be present in patients own endogenous flora, health care persons and from environment sources (Sehulster et al., 2003) Environmental monitoring means the microbiological testing of air, surface and equipment in order to detect changing trends of microbial counts and micro-flora 42

monitoring the capability of the air filters used in the OT s and also helps in assessing quality and making timely changes in measures that need to be adopted in order to maintain air quality in these areas (Javed et al., 2008). The air in operating theatres environment is said to have a role in the causation of postoperative infections. Post-operative infection constitutes a third of all infections. Infection prevention measures that needs to be practiced, to avoid such situation rest not only on operating personnel but would also involve the entire infection control team and role of clinical microbiologist in terms of monitoring air quality. It is in fact estimated that a 13-fold reduction in airborne bacteria in operating rooms would reduce wound contamination by around 50% (Whyte et al., 1992). Air sampling therefore plays important role in monitoring of hygienic conditions in operation theatres. Air samples can be collected in two ways: 1) Active air samplers 2) Passive air sampling (the settle plates). In this study settle plate method was used for air quality monitoring of operation theatres. Settle plates when exposed to the atmosphere, collect particles settling by gravity. This method is simple frequently used, sometimes in preference to other aerobiological samplers. Settle plates are passive method which represents large particles sampled during exposure period because of the faster sedimentation rate. Use of settle plate can provide a hint whether the environment is more or least contaminated with airborne microorganisms (Srikant et al., 2008). The main and objectives of this study includes, to monitor Quality of air in the form of bacterial load in operation theatres by Settle plate method. And to identify the presence of fungi. Also to identify the rate of infection in postoperative patients in respective wards of hospital. Materials and Methods The Study was conducted in department of Microbiology, Government Medical College and Hospital, Aurangabad. The study period was from January 2015 to December 2015. Settle plates were collected from 6 different operational theatres (OTs) in the hospitals. Total numbers of 100 Settle plates were studied in a year. Settle plates were collected once in a month from each OT. The evaluation of bacterial contamination in an operating theatre was performed by using settle plate method. The sterile Blood agar plates were transported to operation theatres in sealed plastic bags. The plates were labelled with sample number, site within the operation theatre, time and date of sample collection and control plates were kept to monitor any prior contamination of plates. During air sampling sterile gloves, mouth mask and protective gown were worn to prevent self-contamination of the blood agar plate. The index of microbial air contamination was based on the count of the microbial fallout on to petridishes left open to the air according to the 1/1/1 scheme (for 1 hour, 1meter above the floor, at least 1m away from walls or any obstacle). After this exposure, the plates were covered with their lids and taken to Microbiology laboratory in sealed plastic bags and incubated in incubator at 37 o C for 24 hours The culture plates that showed discrete macroscopic colonies were counted using digital colony counter. The colonies were assessed for the growth of potential pathogenic bacteria 43

initially by colony characteristics, haemolysis pattern and microscopic examination of Gram stained smears. Final identification was done following standard bacteriological techniques. The concentration of airborne bacteria was expressed as colony forming units per cubic meter (cfu/m 3). Settle plate showing fungus was also noted. LCB mount of fungi was done to identify it. Patients who had undergone surgeries at the time of air quality monitoring, were followed up for any postoperative surgical site wound infection. Reporting of Settle Plates 1. Single CFU of Staphylococcus spp., Pseudomonas spp., any fungi. 2. >50 CFU of Gram negative bacteria other than Pseudomonas spp. Formula for Conversion of Colony Count (on settle plate) to Counts / m 3 CFU/m 3 = a 1000 p t 0.2 a = The number of colonies on Settle plate. p = The surface measurement of plate used. t = Time of exposure of settle plate. Results and Discussion In Table 1: Out of 100 settle plates observed from OTs 28 plates were showing growth of organisms and were positive and the report was given as not satisfactory. Among 28 positives OT 1 and OT 4 both shows 9 and 8 settle plates of maximum positives respectively.ot3 shows 5, OT 2 shows 4 and CVTS and CVTS Cath lab shows positive for one settle plates each. Table no. 2: Among 28 positive samples from different OTs, OT 1 had maximum positivity that is 32.15%, OT 2 had 14.29% 44 of positive samples, OT 3 had 17.85% of positive samples, OT 4 had 28.57% of positive samples, CVTS OT and CVTS cath lab had 3.57% of positive samples each. Table no. 3: Out of 28 settle plates positives maximum 16 (57%) plates showed colonies of Staphylococcus aureus, 2 (7%) plates showed fungal colonies of Aspergillus niger and 2 (7%) plates showed colonies of Pseudomonas spp. 8 (29%) plates showed significant colony counts of other bacteria. Corrective Actions were advised to take in OT showing non significant 1. Cleaning of OT with liquid soap and water after removal of dust on all surfaces. 2. Cleaning OT tables, lamps, trolleys with proper disinfectant. 3. Fumigation of OT. 4. Restrict entry of personnel in OT and wear masks and caps while in OT. The microbiological quality of air in operation theatre has a huge bearing on the outcome of any surgical procedure. The microbiological quality of air can indeed be considered as a reflection of the hygienic condition of operating room. In our study out of 100 settle plates studied 28 plates were found to be positives. Among the total operational theatre studied OT1 and OT 4 in our hospital were showing positives for gram positive cocci, gram negative bacteria and fungi. Analysis of the settle plates (passive) method from various operational theatres for microbial load has shown 57% of Gram positive cocci to be predominant. Similar isolation was shown in study done by Rajni Sabharwal et al., 2015. Gram negative bacteria were detected in7%

and found to be Pseudomonas species. Fungi were also isolated in 7% of which was identified as Aspergillus niger. Grampositive bacteria isolated from the plates were predominantly of cocci in nature and were pathogenic and found to be Staphylococcus aureus. Table.1 Shows Total Numbers of Settle Plates Showing Positives in Different OTs. Sr. No OT number Number of Settle Plates showing Settle plate showing in hospital settle plates growth (Positive) no growth observed (Negative) 1. OT 1(all blocks) 31 9 22 2. OT2 (all blocks) 20 4 16 3. OT3 (all blocks) 18 5 13 4. 0T 4 (all blocks) 22 8 14 5. CVTS OT 4 1 3 6. CVTS Cath lab 5 1 3 TOTAL 100 28 72 Table.2 Shows Percentage Distribution of all Positive Samples from different OTs. OT Positive samples Percentage of Positivity (%) OT 1 9 32.15 OT 2 4 14.29 OT 3 5 17.85 OT 4 8 28.57 CVTS OT 1 3.57 CVTS Cath lab 1 3.57 TOTAL 28 100 Table.3 Distribution of Organism isolated from positive samples. Organism Isolated Number of plates Percentage (%) Staphylococcus aureus 16 57 Pseudomonas spp. 2 7 Aspergillus niger 2 7 Other bacteria 8 29 Total 28 100 45

Fig.1 Shows Out of 100 Settle Plates Studied 72% Samples were Satisfactory and 28% Samples Were Unsatisfactory. Fig.2 Shows Distribution of Unsatisfactory Samples,1 Showed 29% Unsatisfactory samples, OT 2 showed 14% unsatisfactory samples, OT3 had 18% unsatisfactory samples while OT 4, CVTS OT and CVTS Cath lab had 29%, 3% and 7% unsatisfactory samples respectively. 46

Fig.3 Shows Percentage Distribution of Different Organisms Isolated from Unsatisfactory Samples from all ots. 57% samples had colonies of staphylococcus aureus, 7% samples showed colonies of pseudomonas species, 7% samples had fungal colonies of Aspergillus niger and 29% samples had significant colony count of other gram negative bacteria (other than pseudomonas species). 47

Many studies have suggested that higher concentrations of these cocci can be attributed to the lower susceptibility of these organisms to environmental stresses, due to the presence of pigments and higher peptidoglycan contents in their cell walls, which provides protection from drying and heat stress (Raymond et al., 2001) Other reasons include improper ventilation whose effect is worsened when the number of people present are beyond the room s reasonable capacity, since the main source of Staphylococci are people who shed these cocci from skin, clothing, and hair (Borriello et al., 2005). Gram negative bacteria get generated and dispersed in air in the form of aerosols from contaminated fluids from humidifiers, nebulizers, and wet cleaning equipment (Ayliffe et al., 1982). Earlier studies, however, have shown that Pseudomonas species are ubiquitous and found to be present in air, soil and other inanimate objects (Rughooputh et al., 2001). They are difficult to eradicate from hospital wards as it is resistant to and may multiply in many of disinfectant and antiseptics commonly used in hospitals (Zimakoff et al., 1983). Fungus like Aspergillus species can be transmitted from patients or the environment. Aspergillus species may be dangerous for patients of risk group. The tiny spores readily invade upper and lower airways and may produce lung Aspergillus in risk group patients (Anaissie et al., 2003). In conclusion, harbouring of potential pathogens in OTs of hospital can pose a great risk to patients. Monitoring the bio load of air helps in assessing the capability of air filters used in the OT s and also helps in assessing quality and making timely changes in measures that need to be adopted. This data can be used to set regional standards for levels of acceptable microbial population and can also be used to suggest suitable guidelines in order to decrease the microbial rates in indoor air. Reference Anaissie, E.J., et al. 2003. Pathogenic molds (including Aspergillus species.) in 48

hospital water distribution system: A 3 year prospective study and clinical implication for patients with hematologic malignancy Blood. 101: 2542-2546. Ayliffe, G.A.J., Lowbury, E.J.L. 1982. Airborne infection in hospital. J. Hosp. Infect., 3: 217 240. Bhalla, A., Aron, D.C., Donskey, C.J. 2007. Staphylococcus aureus intestinal colonization is associated with increased frequency of S. aureus on skin of hospitalized patients. BMC Infect. Dis., 7(1): 1. Borriello, P.S., Murray, P.R., Funke, G. 2005. In Topley and Wilson s Microbiology and Microbial Infections: Bacteriology-I, 10 th edn, Washington D C, American Society for Microbiology Press, 2005, pp. 185 194. Javed, I., Hafeez, R., Zubair, M., Anwar, M.S., Husain, S. 2008. Microbiological surveillance of operation theatres and ICUs of a tertiary hospital, Lahore Biomedica, vol 24: 99-102. Rajni Sabharwal, E., Rajni Sharma. 2015. Estimation of microbial air contamination by settle plate method: are we within acceptable limit. Sch. Acad. J. Biosci., 3(8): 703-707, ISSN 2347-9515. Raymond, D.P., Pelletier, S.J., Crabtree, T.D., Schulman, A.M., Pruett, T.L. 2001. Surgical infection and the aging population. Am. Surg., 67(9): 827-832. Rughooputh, S. 2001. The role of Pseudomonas aeruginosa in nosocomial infections, Biomed. Scientist. Sehulster, I., Chinn, R.Y. 2003. Guidelines for environment infection control in health care facilities. Recommendations of CDC and the healthcare infection control Practices. Adivisory committee MMWR Recomm Rep., 52: 42. Srikant, P., et al. 2008. Bio aerosols in indoor environment: composition, health effect and analysis. Indian J. Medical. Microbiol., 26(4): 302-12. Whyte, W., Hambraues, A., Laurell, G., Hoborn, J. 1992. The relative importance of the routes and sources of wound contamination during general surgery. II Airborne. J. Hosp. Infect., 22: 41-54. Zimakoff, J., N. Holby, K. Rosendal, Gulbert, J.P. 1983. Epidemiology of Pseudomonas aeruginosa Infection and role of contamination of the environment in a cystic fibrosis, Clin. J. Hosp. Infect., 4: 31-46. How to cite this article: Kasdekar, M.M., M.M. Duthade, A.S. Damle, M.N. Khapurkuntikar, J.A. Iravane, J.B. Bhakre and Gaikwad, A.A. 2016. Air Quality Monitoring of Operation Theaters in Government Medical College and Hospital, Aurangabad. Int.J.Curr.Microbiol.App.Sci. 5(6): 42-49. doi: http://dx.doi.org/10.20546/ijcmas.2016.506.005 49